500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled
|
|
- Bartholomew Casey
- 5 years ago
- Views:
Transcription
1 500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1
2 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU 12470D 3 Phase Energy Efficient Pad Mount Loop Feed Dead Front Transformer from Larson Electronics is powerful, reliable and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU provides increased reliablity and protection against critical equipment failures. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses. The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU features a stainless steel enclosure that is rated NEMA 4X. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 500kVA, the MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU transformer is a three phase unit with a primary voltage of 12470V Delta. It also provides a secondary voltage of 208Y/120 Wye-N. Featuring robust construction, this unit's cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology. This unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The stainless steel NEMA 4X enclosure makes the unit suitable for both indoor and outdoor applications and it can be floor mounted. The unit also features FR3 oil cooling and a 65 C temperature rise and is rated IP66. The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU is designed so that no excess oil heating occurs from unbalanced loads or phase loss on the primary side. Benefits: The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU pad mount loop feed transformer offers many benefits to the consumer. Precision cut copper transformer winding material help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations. This transformer provides owners with significant energy savings as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Integrated floor and wall mounting brackets make installation fast and easy and the offset outward facing floor installation holes allow for easy power tool access. Applications: General purposes. Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at or sales@larsonelectronics.com to discuss your specific requirements. Specifications / Additional Information MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Pad Mount Ratings Transformer Phase: Three Phase Frequency: 60Hz kva: 500 Primary Voltage: 12470V Delta Primary kv Class: 15kV Primary Connection: Delta Primary BIL: 95kV Primary FCAN: 2 x 2.5% Listed for United States and Canada KNAN Cooling IP66 Rated FR3 Oil Filled Dead Front Loop Feed Stainless Steel Enclosure NEMA 4X Primary FCBN: 2 x 2.5% Tap Changer: 100 Amp 5-Position Tap Changer High Voltage Bushings: (6) 200A Copper Bushing Wells & Removeable Studs Inserts: (6) Inserts 15 KV, 95 BIL Copper Load-Break Inserts Load-Breaking Switch: 15KV, 630A 4-Position T-Blade Page: 2
3 Arresters: None Overcurrent Protection: Bayonet Fuses: (3) Current Limiting Fuses; (3) Expulsion Fuses Bayonet Fuses; (3) Copper Bayonet Fuse Holders Secondary Voltage: 208Y/120 Wye-N Secondary Connection: Wye-N Secondary BIL: 30kV Low Voltage kv Class: 1.2kV Low Voltage Bushings: (6) 1" Copper Studs w/ 6-Hole Screw-On Spade Bushings Switches: Internal Oil Immersed Gang Operated On/Off Switch; A+B or AB Selector Switch for Primary Side IEEE K-Dimension: Loop Feed per IEEE C Figure 11 Minimum Dimensions (Without Bails) Packaging: Pallet Cover: Bolted Cover Gauges & Fittings: Liquid Level Gauge Gauges & Fittings: Thermometer - Dial Type Gauges & Fittings: Schrader Valve Gauges & Fittings: 1" Drain Valve w/ Sampler in LV Compartment Gauges & Fittings: Pressure Relief Device, 50 SCFM Gauges & Fittings: 1" Fill Valve Tank Accessories: (3) IEEE Standard One-Hole Ground Pads Tank Accessories: Nitrogen Blanket Winding Material: Copper Efficiency: DOE CFR Part 431 Cooling Class: KNAN Insulating Fluid: FR3 Oil Fluid Volume: - Fluid Weight: - Elevation: Designed for Operation at 1000M (3300') Above Sea Level Temperature Rise: 65 C Impedance (Std): - Sound Level: NEMA TR1 Standard Cabinet: 20" Deep Cabinet Cabinet Hardware: Penta-Head Cabinet Door Bolts Special Orders- Requirements Page: 3
4 Enclosure Material: Stainless Steel - NEMA 4X Rated Contact us for special requirements Dimensions: - Toll Free: Weight: - Intl: Mounting: Pad Mount sales@larsonelectronics.com -Scroll Down to Purchase- Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU (149902) Page: 4
5 Links (Click on the below items to view): - Page: 5
1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled
1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R
More information750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R
750 kva Transformer - 12470V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R Part #: MT-PMD-3P-12470D-750KVA-480Y.277-N3R Page: 1 The MT-PMD-3P-12470D-750KVA-480Y.277-N3R 12470D 3 Phase
More information45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings
45 kva Isolation Transformer 480V Delta Primary 400V Delta Secondary N3R Copper Windings Part #: MTDOE163P480D45KVA400DN3RCU Page: 1 The MTDOE163P480D45KVA400DN3RCU 480D 3 Phase Energy Efficient Isolation
More information90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R
90 kva Transformer 208Y WyeN Primary Voltage 230Y WyeN Secondary Voltage NEMA 3R Part #: MT208Y90KVA230Y3P Page: 1 The MT208Y90KVA230Y3P 208Y 3 Phase Energy Efficient Transformer from Larson Electronics
More information75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding
75 kva Transformer 480V Delta Primary 208Y/120 WyeN Secondary NEMA 3R K13 Copper Winding Part #: MTK13FP3P480D75KVA208Y.120N3RESCU Page: 1 The MTK13FP3P480D75KVA208Y.120N3RESCU 480 V Delta 3 Phase Energy
More information30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R
30kVA Transformer 3 Phase 480 Delta Primary 380Y/220 or 400Y/230 Secondary NEMA 3R Part #: MT480D30KVA380.400V Page: 1 The MT480D30KVA380.400V 480V 3 Phase Energy Efficient transformer from Larson Electronics
More information112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R
112.5 kva Isolation Transformer 440V Delta Primary 110V Delta Secondary NEMA 3R Part #: MTISX3P440D112.5KVA110DN3R Page: 1 The MTISX3P440D112.5KVA110DN3R 440 V Delta 3 Phase Energy Efficient Distribution
More information75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R
75 kva Transformer 208V Delta Primary Voltage 480V Delta Secondary Voltage NEMA 3R Part #: MTATX3P208D75KVA480DN3R Page: 1 The MTATX3P208D75KVA480DN3R 208D 3 Phase Energy Efficient Transformer from Larson
More information30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings
30 KVA Transformer 480V 3 Phase to 208Y/120V NEMA 3R Enclosure Copper Windings Part #: MT30KVA3P480V208.120CU Page: 1 MT30KVA3P480V208.120CU 30kVA Transformer 480V 3 Phase480V Delta Primary Voltage 208Y/120V
More information75 kva Isolation Transformer - 480Y Wye-N Primary - 208Y/120V Secondary - NEMA 3R Enclosure
75 kva Isolation Transformer 480Y WyeN Primary 208Y/120V Secondary NEMA 3R Enclosure Part #: MTISX3P480Y75KVA208Y.120N3R Page: 1 The MTISX3P480Y75KVA208Y.120N3R 480Y 3 Phase Energy Efficient Isolation
More information112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R
112.5 kva Transformer 480 Delta Primary 240/120V Secondary 60 Hz 3 Phase NEMA 3R Part #: MT112.5KVA480240.1203P Page: 1 The MT112.5KVA480240.1203P 480D 3 Phase Energy Efficient isolation transformer from
More information1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration
1TSF14000167/CD LINE ITEM 1: 37,5 KVA 1 PHASE PAD MOUNTED TRANSFORMER, ENVIROTEMP FR3 37.5 KVA, 10 Pad Mounted Transformer, AIMS! TYPE 2 SHRUBLINE insulating fluid 12470 Deita Two position ioadbreak switch
More information*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*
Power Distribution System - 10KVA - (1) 480V Outlet - (6) 5-20 GFCI Outlets Part #: MGS-480.1X100A-10K-6X120 Made in the USA. The Larson Electronics MGS-480.1X100A-10K-6X120 heavy duty power transformer
More informationDistribution Transformers
Distribution Transformers PEAK Three-Phase Pad-mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted PEAK Distribution Transformers 45 10,000 kva
More informationDistribution Transformers
Distribution Transformers Three-Phase Pad-Mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted Distribution Transformers 45 10,000 kva 1.0 Scope
More informationPower Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet
Power Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet Part #: MGPD-2X480-30A-30KVA-10X120-2X220 MADE IN THE USA This Larson Electronics 30KVA Power Distribution
More information75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R V and 8 120V Outlets
75 KVA Transformer Power Distribution - 480V to 120/208V - Nema 3R - 6 208V and 8 120V Outlets Part #: MPD-480-200MB-75K-6X208-8X120 MADE IN THE USA This Larson Electronics 75KVA Power Distribution Substation
More informationC. System Design and Performance Requirements
Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16361-E-E to 26 10 03, removed references to other section numbers A. Summary - mgl44 Change Approver
More informationPower Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet
Power Distribution - 30KVA - 480V to 120V & 220V - Ten 120 Volt GFCI Outlets - Two 220 Volt Outlet Part #: MGPD-2X480-30A-30KVA-10X120-2X220 MADE IN THE USA This Larson Electronics 30KVA Power Distribution
More informationPower Distribution System kva transformer P to 120/240 1P - 20X 120 Outlets and 2X 240
Power Distribution System - 37.5 kva transformer - 480 1P to 120/240 1P - 20X 120 Outlets and 2X 240 Part #: MGS-30KVA-20X120-2X240 Page: 1 Made in the USA The Larson Electronics MGS-30KVA-20X120-2X240
More information75 KVA Transformer Power Distribution - Three Phase 480V to Single Phase 120/240V - Nema 3R
75 KVA Transformer Power Distribution - Three Phase 480V to Single Phase 120/240V - Nema 3R Part #: MPD-480-4X125A-75K-5X240-8X120 MADE IN THE USA This Larson Electronics 75KVA Power Distribution Substation
More informationMobile Power Distribution Center - Input 240D/120V 200A - Output (8) 120v GFCI & (2) 240V Outlets
Mobile Power Distribution Center - Input 240D/120V 200A - Output (8) 120v GFCI & (2) 240V Outlets Part #: MDC-240-200MB-8X120-2X240 Made in the USA The Larson Electronics MDC-240-200MB-8X120-2X240 Mobile
More informationSECTION PADMOUNT TRANSFORMER - OIL FILLED
SECTION 26 12 19.01 PADMOUNT TRANSFORMER - OIL FILLED PART 1 GENERAL 1.1 DESCRIPTION: Padmount Transformers and Insulating Oil with underground primary and secondary connections for use in distribution
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationGENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17
GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT
More informationSPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.
City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization
More informationProudly Made In America
Proudly Made In America VanTran Introduction VanTran Industries, Inc. is a manufacturer of liquid-filled transformers for the industrial, commercial, solar, and utility markets. We are known for engineering
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationMATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationSingle-phase pad-mounted step voltage regulator
Voltage Regulators Catalog Data CA225002EN Supersedes February 2015 COOPER POWER SERIES Single-phase pad-mounted step voltage regulator General Eaton's Cooper Power series single-phase pad-mounted voltage
More informationNEW Solutions for Underground System Growth
NEW Solutions for Underground System Growth Cooper s Single-Phase Voltage Regulator Improved Power Quality More Economical Improved System Reliability Increased Safety Better Aesthetics Lower Maintenance
More informationSubstation Transformers
Substation Transformers PEAK Substation Transformers Electrical Apparatus 210-90 GENERAL Cooper Power Systems PEAK Substation Transformers are a class of transformer technologies that are designed to improve
More informationUnit Substation Transformers 5 and 15 KV Class
Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical
More informationwww. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit
Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design,
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationABB Transformadores para aplicaciones solares y eolicas
ABB Transformadores para aplicaciones solares y eolicas Product offering overview - Jeff City 1Ø and 3Ø pad-mounted transformers 10-250 kva 45-3000 kva ABB Group abril 9, 2016 Slide 2 Product offering
More informationINESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation
MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing
More informationDrive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer
Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer This document contains sample specifications for Liquid-Filled Type Drive Transformers You may
More informationwww. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open
Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,
More informationClass I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationSingle-Phase Step Voltage Regulators
Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4
More informationSingle-phase step voltage regulators
Voltage Regulators Catalog Data CA225001EN Supersedes 225-10 February 2014 COOPER POWER SERIES General Eaton's Cooper Power series VR-32 singlephase step voltage regulators are tap-changing autotransformers.
More informationHPS EnduraCoil. Cast Resin Transformer
HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationMATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.12 and ComElectric Spec 6-0895**** 1.0 General Requirements SINGLE PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMERS 1.1 These specifications cover single-phase
More informationFigure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES
Voltage Regulators Single-Phase Pad-mounted Step GENERAL McGraw-Edison Single-Phase Padmounted Voltage Regulators add a dimension to underground system planning. They provide system planners freedom to
More informationwww. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1
WeSTinghouse Descriptive Bulletin 47-156 Page 1 liquid Filled, Self-Contained 112% 2500 Kva June, 1974 Supersedes DB 47-350, dated August 1972 E, D, C/2082/DB Descriptive Bulletin 47-156 Page 2 Westinghouse
More informationTECHNICAL SPECIFICATIONS OIL FILLED PADMOUNTED THREE PHASE WYE-WYE TRANSFORMERS
TECHNICAL SPECIFICATIONS OIL FILLED PADMOUNTED THREE PHASE WYE-WYE TRANSFORMERS I. GENERAL This specification covers three phase wye-wye padmounted transformers and is used in conjunction with the Specifications
More informationThree Phase Padmounted Transformers kva
Three Phase Padmounted Transformers 45-3000 kva Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationJefferson Electric Class I Division 2 Transformers for hazardous locations
Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division
More informationThree Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts
Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts Part #: EPSW-3PH-60-EB Page: 1 The EPSW-3PH-60-EB Three Phase Explosion Proof Switch by Larson Electronics is a
More information1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage
1500 kva Padmount Transformer 12470 delta Primary Voltage 208Y/120 Secondary Voltage Cooper Power Systems Proposal Number: BED1096719 Date: January 4, 2010 Revision 00 Item Number: 00001 Item Details Customer
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationINSTRUCTION MANUAL #103
INSTRUCTION MANUAL #103 www.ermco eci.com THREE PHASE PAD MOUNT DISTRIBUTION TRANSFORMER General instruc ons for installa on and opera on of Three Phase Pad Mount Distribu on Transformer. 2 INTRODUCTION
More informationDISTRIBUTION TRANSFORMERS SPECIFICATION #
DISTRIBUTION TRANSFORMERS SPECIFICATION #1212.01 12.47kV Grd Wye Padmount & Polemount Bid No. 16-93 Exhibit I Page 1 of 19 TABLE OF CONTENTS 1 SCOPE... 3 2 STANDARDS... 3 3 EVALUATION AND AWARD... 3 4
More informationPadmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage
Padmount Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage ABB s Padmounted Transformers provide tamper-resistant protection in
More informationOutdoor Power Transmission & Distribution
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:
More informationFeatures, Benefits and Functions
-8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor
More informationwww. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva
Westinghouse Descriptive Bulletin 47-256 Page 1 PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 3-Phas8, Liquid-Immersed 750 Thru 2500 Kva Application The Westinghouse Plazapad
More informationRELIABLE POWER COOPER POWER SYSTEMS. Transformer Products Group FROM
P R O D U C T G U I D E RELIABLE POWER FROM COOPER POWER SYSTEMS Transformer Products Group Transformer Products by Cooper Power Systems Cooper Power Systems, with its combination of McGraw- Edison, Kyle,
More informationEfficiency is in our DNA
Efficiency is in our DNA EFFICIENCY IS IN OUR DNA EFFICIENCY AND ENERGY-SAVINGS IS PART OF OUR CULTURE From the day the company was founded in 1942, Marcus Transformer has focused its technology on providing
More informationHoward Industries. Single-Phase Step
Howard Industries Utility Products Division Single-Phase Step Catolog Section 28-10 Voltage Regulators INTRODUCTION Howard Industries SVR-1 single-phase step voltage regulators are tapchanging autotransformers
More information24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A
24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A Part #: EXP-IP-POE-INJ-24V-24W Page: 1 The EXP-IP-POE-INJ-24V-24W from Larson Electronics is an Explosion
More informationSingle phase pole mounted. 11kV. Electrical Engineer KEU ID#:
Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type
More informationSUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ
QUALITROL TRANSFORMER BY VANTRAN 10 VAC PSIG 0 5 5 QUALITROL 10 PRESS PSIG 0 40 60 80 20 100 QUALITROL 120 25c SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ 115"
More informationSPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS
SPECIFICATION T-5 SPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS 1.0 GENERAL PURPOSE 1.1 These specifications cover the electrical and mechanical features of a three phase, 60 hertz,
More informationDistribution transformers Efficiency over life-cycle
Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationSingle Phase Padmounted Transformers kva
Single Phase Padmounted Transformers 10-250 kva Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while
More informationDOE 2016 Environmental Benefits
TABLE OF CONTENTS DOE 2016 Efficiency Guidelines HPS DOE Compliant Products Features & Benefits Specifications & Accessories Part Guide Support & Resources Selection Tables - HPS Sentinel G Selection Tables
More informationMinera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards
Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral
More informationDistribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection
7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance
More informationDOE 2016 Environmental Benefits
TABLE OF CONTENTS DOE 2016 Efficiency Guidelines HPS DOE Compliant Products Features & Benefits Specifications & Accessories Part Guide Support & Resources Selection Tables - HPS Sentinel G Selection Tables
More informationExplosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC
9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB
More informationTotally Enclosed Non-Ventilated
5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,
More informationMiscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control
Table of Contents Section General Purpose Dry Type 600 Volts and Below General Purpose Transformer, see page -2 Sealed Transformer, see page -10 90701050D2 Industrial Control Transformer, see page - EE
More informationSubstation Transformers
Substation Transformers Unit Type Substation Transformers Electrical Apparatus 210-15 GENERAL Cooper Power Systems Unit Type Substation Transformers are designed to meet customer specifications. Flexibility
More informationTGK Prefabricated Substation Technical Data
TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does
More informationMIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6
I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load
More informationKey features. DESIGNS: - Conservator type - Hermetically sealed
Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationCAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA
More informationTechnical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationStandard Features and Accessories
14.0-12 Secondary Unit Substations Secondary Below 1000V Product Overview General Description December 2012 Sheet 14012 Liquid-Filled Substation Transformers Application Description Eaton s liquid-filled
More informationPrime Power Energie Systems Inc.
Prime Power Energie Systems Inc. C a s t C o i l Tr a n s f o r m e r s 100 kva to 30 MVA 2 3kV tto 34 2.3kV 34.5kV 5kV Extraordinary Quality, Reliability and Service Energy Efficient Low Total Owning
More informationA 1.2 kv class externally removable secondary bushing
OEM Equipment Catalog Data CA800018EN Supersedes July 2015 COOPER POWER SERIES 3010-4515 A 1.2 kv class externally removable secondary bushing General Eaton s Cooper Power series 3010-4515 A externally
More informationWaterproof DC Power Supply Converts 110V AC (wall outlet) Power to 12 Volts DC for Lights
Waterproof DC Power Supply Converts 110V AC (wall outlet) Power to 12 Volts DC for Lights Part #: DCP-5 The Larson Electronics DCP-5-12V Waterproof Power Supply converts commonly used 100-277VAC electrical
More informationCITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115
CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page
More information15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch
Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationSERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES
SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD
More informationDry Type Distribution Transformers
Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.
More information