ABB Transformadores para aplicaciones solares y eolicas
|
|
- Nathan Dixon
- 5 years ago
- Views:
Transcription
1 ABB Transformadores para aplicaciones solares y eolicas
2 Product offering overview - Jeff City 1Ø and 3Ø pad-mounted transformers kva kva ABB Group abril 9, 2016 Slide 2
3 Product offering overview - Jeff City 1Ø ( kva) and 3Ø submersibles ( kva) ABB Group abril 9, 2016 Slide 3
4 Product offering overview - Jeff City Substation transformers kva ABB Group abril 9, 2016 Slide 4
5 ABB - Jefferson City The technology leader greener solutions Providing energy efficient products and solutions supporting and contributing to reduction of CO2 emissions Product development based on both conventional and new technologies and solutions Liquid Filled Distribution Transformer design features and options Conventional technology high efficiency and low loss designs Amorphous Metal technology for ultra low loss designs Natural ester insulating fluid Biodegradable, non-toxic and high fire point ABB Group abril 9, 2016 Slide 5
6 ABB Jefferson City Wind & Solar Generation Primary Supplier to Wind Generation for more than 25 years Early commercial projects in Tehachapi, CA (1980s) Nearly 4000 GSUs in service from 750 kva to 2750 kva Trusted supplier of GSUs to some of the largest US owner/ developers On-time deliveries Shipment schedules to meet project needs
7 ABB Jefferson City Who Do We Serve Supplier to Many Solar & Wind Developers & Contractors NextEra TMEIC Mortenson BP Wind Brookfield Power Alliant Iberdrola RMT Blattner RES Rosendin Wanzek State Group
8 Unique Cabinet Design Offers Safe & Easy Installation and Access Flip-top weather cover has 4 degree slope to shed water Free floating support arm auto-locks safely into place Cabinet cover is one hand operable for safe & easy access Cabinet cover rotatable over center or fully removable for accessibility
9 Wind Transformer Design Tank ANSI/IEEE C psi w/o permanent distortion 15 psi w/o rupture Corrosion protection ANSI/IEEE C Stainless steel 400 or 300 series (ANSI/IEEE C ) Cross braced coolers
10 Electrical Testing All transformers are fully tested in compliance with IEEE C and C Optional (not an exhaustive list) Sound Temperature rise RIV Partial discharge Extreme taps Power factor Chop wave
11 Wind Transformer Design Fusing for Delta HV Fuse links Current limiting partial range IEEE 23kV parallel Available 38kV current limiting partial range wind fusing
12 Wind Transformer Design VFI Option Up to 150BIL Replaces XFMR switch & Expulsion fusing Manual loadbreak switching Programable fuse curves Invertible positioning SCADA capable module ABB Inc. abril 9, 2016 Slide 12
13 Wind Transformer Design Cabinetry ANSI/IEEE security 3 point door latching Compartment barrier HV door limited access security Heavy SST door stops (3/8 x 18 ) Easy accessibility Corrosion protection ANSI/IEEE C Stainless steel 400 or 300 series (ANSI/IEEE C ) Optional door gaskets
14 Renewables Wind - Safety LV Power Breaker* Arc Flash Transformer Protection System Protection Lightning, HV Surges, etc. Visible and Positive Disconnect Remote Operation & Signaling * Heaters May Be Required in very cold climates Non-conductive barriers
15 Renewables Wind Wind Generation Standard Features Fuses accessible through the tank hand hole Bushing spade supports Heavy 18 SST door stop rods Low flux density design Core ground Removable through the tank hand hole Added bracing on deep coolers Dissolved gas test - baseline
16 Renewables Wind Frequent Optional Features HV and LV cable supports Control boxes external signalling connections Gauges in a control box outside the std. cabinet*-safe-r-pad Drain and sampler in a control box outside the std. cabinet*- Safe-R-Pad Extended drain and sampler accessible just inside the std. cabinet doors Transformer switch in a control box outside the std. cabinet* WTI Siesmic bracing HV and LV arrestors * Not available on all kva due to radiator requirements
17 ABB Jeff City Safe-R-Pad Gauges mounted in a separate enclosure Temperature gauge Liquid level gauge Vacuum-pressure gauge HV switch option Drain valve and sampler in a separate enclosure Enables monitoring without entry to high voltage cabinet Less training and certification required ABB Group abril 9, 2016 Slide 17
18 ABB Jefferson City Wind Generation Consistent product integrity Improved up time yields dependable revenue stream Receive, Energize, and Forget it Assured materials availability Consistent customer support during and after delivery Highly qualified regional shops Response in 24 hrs. / Resolution plan in 48 hrs.
19 ABB Jeff City Manufacturing flexibility ABB Group abril 9, 2016 Slide 19
20 ABB Jefferson City Padmount Transformer ABB Group abril 9, 2016 Slide 20
21 ABB Jefferson City Padmount Transformer ABB Group abril 9, 2016 Slide 21
22 ABB Jefferson City Products Padmount Transformer ABB Group abril 9, 2016 Slide 22
23 ABB Jefferson City Products Padmount Transformers ABB Group abril 9, 2016 Slide 23
24 ABB Jefferson City Products Padmount Transformer ABB Group abril 9, 2016 Slide 24
25 ABB Jefferson City Products Secondary Unit Substation ABB Group abril 9, 2016 Slide 25
26 ABB Jefferson City Products Secondary Unit Substation ABB Group abril 9, 2016 Slide 26
27 ABB Jefferson City Products Secondary Unit Substation ABB Group abril 9, 2016 Slide 27
28
1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled
1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R
More information500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled
500 kva Pad Mount Transformer - 12470V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU
More informationGENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17
GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT
More information1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration
1TSF14000167/CD LINE ITEM 1: 37,5 KVA 1 PHASE PAD MOUNTED TRANSFORMER, ENVIROTEMP FR3 37.5 KVA, 10 Pad Mounted Transformer, AIMS! TYPE 2 SHRUBLINE insulating fluid 12470 Deita Two position ioadbreak switch
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationCLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationDistribution Transformers
Distribution Transformers Three-Phase Pad-Mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted Distribution Transformers 45 10,000 kva 1.0 Scope
More informationwww. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit
Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design,
More informationSubstation Transformers
Substation Transformers PEAK Substation Transformers Electrical Apparatus 210-90 GENERAL Cooper Power Systems PEAK Substation Transformers are a class of transformer technologies that are designed to improve
More informationDistribution Transformers
Distribution Transformers PEAK Three-Phase Pad-mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted PEAK Distribution Transformers 45 10,000 kva
More informationThree Phase Padmounted Transformers kva
Three Phase Padmounted Transformers 45-3000 kva Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while
More informationA. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.
1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall
More informationINESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation
MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More informationDrive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer
Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer This document contains sample specifications for Liquid-Filled Type Drive Transformers You may
More informationSECTION PADMOUNT TRANSFORMER - OIL FILLED
SECTION 26 12 19.01 PADMOUNT TRANSFORMER - OIL FILLED PART 1 GENERAL 1.1 DESCRIPTION: Padmount Transformers and Insulating Oil with underground primary and secondary connections for use in distribution
More informationPower Voltage Transformers for Air Insulated Substations
Power Voltage Transformers for Air Insulated Substations Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the application of a
More informationRPS Station. Solutions for the North American Solar Market
RPS Station Solutions for the North American Solar Market 2013/2014 Power, control and green solutions 3 RPS Station s RPS Station is a fully integrated photovoltaic power conversion system that is designed
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More information750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R
750 kva Transformer - 12470V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R Part #: MT-PMD-3P-12470D-750KVA-480Y.277-N3R Page: 1 The MT-PMD-3P-12470D-750KVA-480Y.277-N3R 12470D 3 Phase
More informationDistribution transformers Efficiency over life-cycle
Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationSPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.
City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization
More informationNEW Solutions for Underground System Growth
NEW Solutions for Underground System Growth Cooper s Single-Phase Voltage Regulator Improved Power Quality More Economical Improved System Reliability Increased Safety Better Aesthetics Lower Maintenance
More informationSolid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER
Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationwww. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open
Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,
More informationHigh Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide
1ZUA2761-500 rev. 5, 6 April 2010 High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide 1ZUA2761-500 rev. 5, 6 April 2010 2 / 9 Table of contents 1 Description... 3 2 Ratings...
More informationC. System Design and Performance Requirements
Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16361-E-E to 26 10 03, removed references to other section numbers A. Summary - mgl44 Change Approver
More informationSubmersible Vacuum Fault Interrupters
Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationSubstation Transformers
Substation Transformers Unit Type Substation Transformers Electrical Apparatus 210-15 GENERAL Cooper Power Systems Unit Type Substation Transformers are designed to meet customer specifications. Flexibility
More informationMATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****
Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1
More informationINSTRUCTION MANUAL #103
INSTRUCTION MANUAL #103 www.ermco eci.com THREE PHASE PAD MOUNT DISTRIBUTION TRANSFORMER General instruc ons for installa on and opera on of Three Phase Pad Mount Distribu on Transformer. 2 INTRODUCTION
More informationProduct Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More information16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12
16kA Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A continuous current, 16kA symmetrical interrupting
More informationH1 H2 H3 X0 X1 X2 X3
H0 H H H H0 H H H X0 X X X X0 X X X S- S- S- S- FB H0 H H H X0 X X X H0 H H H X0 X X X 7 NOTES:. ITEMS REMOVED FOR SHIPMENT. TANK DESIGNED FOR FULL VACUUM. MANUFACTURED IN ACCORDANCE WITH ANSI
More informationSERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES
SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD
More informationFigure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES
Voltage Regulators Single-Phase Pad-mounted Step GENERAL McGraw-Edison Single-Phase Padmounted Voltage Regulators add a dimension to underground system planning. They provide system planners freedom to
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationBrochure. Modular Systems wind portfolio Power Collection and Grid Connection products
Brochure Modular Systems wind portfolio Power Collection and Grid Connection products Wind portfolio Background ABB is one of the few suppliers that has been deeply involved in wind power segment development,
More informationTGK Prefabricated Substation Technical Data
TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary
More informationSingle Phase Padmounted Transformers kva
Single Phase Padmounted Transformers 10-250 kva Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationChapter 6 Generator-Voltage System
Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals
More informationSingle phase pole mounted. 11kV. Electrical Engineer KEU ID#:
Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type
More informationSECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS
CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION
More informationCATALOG. Hi-Tech Fuse Products
CATALOG Hi-Tech Fuse Products Thomas & Betts is now ABB Installation Products, but our long legacy of quality products and innovation remains the same. From connectors that help wire buildings on Earth
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationType SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.
Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings
More informationABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers
ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type
More information"#$%&'(%)*#$ Installation, Operation, and Maintenance of Three-Phase Padmounted Distribution Transformers 45 kva through 10,000 kva
"#$%&'(%)*#$ Installation, Operation, and Maintenance of Three-Phase Padmounted Distribution Transformers 45 kva through 10,000 kva 1 Three-Phase Padmounted Distribution Transformers READ THIS IMPORTANT
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More informationUnit Substation Transformers 5 and 15 KV Class
Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical
More informationFigure 1. Two and Three-phase MagneX.
Fusing Equipment Two- & Three-Phase MagneX Interrupter Electrical Apparatus 240-33 GENERAL The Cooper Power Systems MagneX Interrupter is an overcurrent protective device that protects distribution transformers
More informationA 1.2 kv class externally removable secondary bushing
OEM Equipment Catalog Data CA800018EN Supersedes July 2015 COOPER POWER SERIES 3010-4515 A 1.2 kv class externally removable secondary bushing General Eaton s Cooper Power series 3010-4515 A externally
More informationSingle-Phase Step Voltage Regulators
Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4
More informationMaximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026
TECHNICAL PERTICULAR FOR 1.6 MVA 6.6/0.433 KV SERVICE TRANSFORMER 1.00.00 GENERAL 1.01.00 Service SERVICE 1.02.00 Make ASHOK/VOLTAMP/DANKE/CGL 1.03.00 Type CORE 1.04.00 Location OUTDOOR 1.05.00 Specification
More informationME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position
LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble
More informationCITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008
CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 SPECIFICATION NO: ELE_112_R1.doc Page 1 of 3 Rev. 10/28/2008 SPECIFICATION
More informationHPS EnduraCoil. Cast Resin Transformer
HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does
More informationUnderground Distribution Switchgear
Underground Distribution Switchgear Type VFI, Vacuum Fault Interrupter Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear
More informationPadmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage
Padmount Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage ABB s Padmounted Transformers provide tamper-resistant protection in
More informationIssued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller
Number: 5344-1.1.311 Rev. 8 Portable Mine Power Centres Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller SCOPE This specification covers general material and design
More informationDescriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG TM is truly the next generation in medium voltage vacuum circuit breaker
More informationABB Automation & Power World: April 18-21, 2011 WRE Optimal transformer selection for renewable energy. ABB Inc. April 20, 2011 Slide 1
ABB Automation & Power World: April 18-21, 2011 WRE-111-1 Optimal transformer selection for renewable energy ABB Inc. April 20, 2011 Slide 1 WRE-111-1 Optimal transformer selection for renewable energy
More informationyour Green Power WIND POWER SOLUTIONS only Greener
your Green Power WIND POWER SOLUTIONS only Greener WIND POWER SOLUTIONS Thomas & Betts is committed to being your partner in power delivery by leading the industry in innovative wind power solutions and
More informationIndependent Testing Laboratory for High Voltage Equipment
T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.
More informationR-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More information34-SDMS-02 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationEnergy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.
Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that
More informationDO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.
DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw
More informationUniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions
UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that
More informationCPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards
Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1
More informationTransformer Components & Accessories
Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationUBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit
More informationMedium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1
Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear ABB Group February 25, 2015 Slide 1 SafeGear HD arc resistant switchgear 63 ka arc resistant metal-clad air insulated switchgear
More informationMEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES
MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES Description JRS arc-resistant fused/non-fused load break and fused/non-fused disconnect switches are available for applications
More informationX-Limiter full-range current-limiting fuse
Fusing Equipment Catalog Data CA132050EN Supersedes 240-56 June 2012 COOPER POWER SERIES X-Limiter full-range current-limiting fuse General Eaton's Cooper Power series X-Limiter full-range current-limiting
More informationFIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z
PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification
More informationModular integrated transportable substation (MITS)
Technical Data TD027002EN transportable substation (MITS) Contents Description Page Voltage regulation with bypassing........................................................ 2 Mobile MITS application...............................................................
More informationTransformer Technology Seminar HV Collector (Power) Transformers
Pomona, CA, May 24 & 25, 2016 Transformer Technology Seminar HV Collector (Power) Transformers siemens.com/answers Substation for Wind Park Switch Yard HIS, Transformer & MV / Aux Building Page Page 2
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ
QUALITROL TRANSFORMER BY VANTRAN 10 VAC PSIG 0 5 5 QUALITROL 10 PRESS PSIG 0 40 60 80 20 100 QUALITROL 120 25c SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ 115"
More informationEE 741 Over-voltage and Overcurrent. Spring 2014
EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with
More informationCITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115
CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page
More informationSingle-phase pad-mounted step voltage regulator
Voltage Regulators Catalog Data CA225002EN Supersedes February 2015 COOPER POWER SERIES Single-phase pad-mounted step voltage regulator General Eaton's Cooper Power series single-phase pad-mounted voltage
More informationProudly Made In America
Proudly Made In America VanTran Introduction VanTran Industries, Inc. is a manufacturer of liquid-filled transformers for the industrial, commercial, solar, and utility markets. We are known for engineering
More informationDescriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv
Descriptive Bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology.
More information