flex7 ZoneLite - Offices Lighting connection & control unit

Size: px
Start display at page:

Download "flex7 ZoneLite - Offices Lighting connection & control unit"

Transcription

1 flex7 ZoneLite - Offices Lighting connection & control unit Type G - Configured for use in single, multiple or open plan offices, & retail environments flex connectors

2 flex7 ZoneLite Features & Benefits A lighting connection & control solution in one, that comes preprogrammed with up to distinct lighting configurations common to general office environments. Offering a prefabricated alternative to traditional wiring, the ZoneLite Type G is designed for use in general office environments. It provides options for absence/presence/daylight linking/graduated daylight dimming lighting control, emergency test, corridor hold, last man out switch and scene setting. Control up to lighting channels Available with, 6 or 0 outlets preconfigured lighting layout options Cost Effective System simply plugs together, saving time on site, and reducing need for skilled electricians. No Commissioning Required Just choose the required configuration using the rotary selector switch on your ZoneLite (detailed in following pages). 9 A B C E F Protected Extra Low Voltage (PELV) Global Switch Inputs All sensor heads and switch drops operate at PELV. This allows us to use lightweight plug-in switch drops and sensor leads. In particular because our switch drops operate at PELV they do not require enclosing in an earthed metallic covering nor the protection of an RC as is often the requirement for mains switch drops. Quick And Easy To Wire Large wiring compartment. Remove cover with a single screw. Each ZoneLite can also accept up to global switch commands: Emergency Test - tests emergency fittings. Last Man Out - initiates all connected luminaires off. All Lights On - initiates all connected luminaires on. (Global switch inputs are typically connected to a group of ZoneLites). Corridor Hold Interlinking corridor hold between a group of ZoneLites allows circulation areas and exit routes to be illuminated when outlying spaces are occupied.

3 Installation Once the ZoneLite has been wired, simply: Select your configuration Plug-in pre-wired flex7 leads, and connect to luminaires Plug-in sensor heads Plug-in switch drop leads Use Remote Control to make any adjustments to brightness, timeout periods etc. Sensor head To channel luminaires To channel luminaires To channel luminaires To channel luminaires Adding outlets If the ZoneLite Unit has insufficient outlets use double extender leads to create more. PELV Switch drop (Switch not included) Various Simple Fixing Options Solid Surface Cable Basket Trunking rop Rods Conduit Box

4 9ABCEF08 9ABCEF08 Configuration Options Note: Many adaptions to each option are possible during setup. Please enquire if you can t find a configuration that exactly matches your specific requirements. Key: Channel - represents channel controlling the luminaire immable Luminaires- if is not present then denotes non-dimmable luminiaires Shading represents brightness (degree of which represents daylight linking in action). Option : Operation: row daylight Each switch operates luminaires bound within the same colour dotted line - On, Off or im (up/down). aylight linking - The window row will daylight link according to the natural light level detected. On vacation of the space any luminaires left on will switch off after an adjustable time-out period (default 0min). row daylight Option : acated Config. See pages & Operation: ithin its in - ylight whilst each subsequent row has a progressively brighter offset row daylight Operates all luminaires bound within red dotted line - On, Off or im (up/down). stage offset daylight linking - Referencing from the window row, back rows will have a brighter offset (offset value is adjustable). On vacation of the window of the space any luminaires left of on the will window switch off row after on the an adjustable time-out period row (default on the 0min). Space Space Option : Config. See pages 8 & This window of the window of other the window side of row the on room the Space Space 9ABCEF08 This window of the window of other the window side of row the on room the Space Space Operation: Operates all luminaires bound within red dotted line - On, Off or im (up/down). stage offset daylight linking - Both window rows daylight link of one another whilst their respective inner rows will have brighter offsets. On vacation of the space any luminaires left on will switch off after an adjustable time-out period (default 0min). Space Space Config. 5 See pages & 5 6 7

5 ABC will row switch daylight off after a whilst time-out each period subsequent (default row 0min). has Note: Our policy of continuous a progressively improvement brighter offset means configurations may change Wall switch - Each switch operates all the luminaires bound within its from time to same time. colour Please dotted refer line. Typically to data - On, sheet Off, for im latest up/down information. (but some cases On, Off only) Option : Config. See pages 6 & 7 Option 5: See pages 0 & whilst both back rows follow Config. Channel - Represents the channel controlling the luminaire. immable Luminaire - If is not present then denotes Non - dimmable luminaire. Shading represents brightness (degree of which represents daylight linking in action) of the window Space with a brighter offset EF0 9ABCEF08 whilst both back rows follow Space Space Space Space of the window Space whilst each subsequent row has a progressively brighter offset of the window Space Partition wall Partition wall switch with a brighter offset of the window Space Operation of space : Operates all luminaires bound within red dotted line - On, Off or im (up/down). Operation of space : Operates luminaires 9ABCEF08 bound within blue dotted line - Config. On, Off or im (up/down). See pages 8 & 9 All areas: Operation Space of partitioned space : Space Operates all luminaires bound within red dotted line - On, Off or im (up/down). Operation of partitioned 9ABCEF08 space : Config. Operates 5 luminaires bound within blue See pages & dotted line - On, Off or im (up/down). Operation with of unpartitioned a brighter offset space & : or All areas: Space Operates all luminaires bound within BLACK dotted line - On, Off or im (up/down). On vacation of each space any luminaires left on will switch off after an adjustable time-out period (default 0min). stage offset daylight linking - Referencing from the window row, back row will have a brighter offset. (offset value is adjustable). Space Space Switches between partitioned and non-partitioned space Space whilst both back rows follow Space Space row daylight On vacation of each space any luminaires left on will switch off Space after an adjustable time-out period (default Space 0min). stage offset daylight linking - Referencing from the window row, back row will have a brighter offset (offset value is adjustable). of the window of the window whilst both back rows follow with a brighter offset Option 6: Config. 6 See pages & ABCEF08 whilst both back rows follow with a brighter offset Space Space whilst both back rows follow with a brighter offset Config. 7 See pages 6 & 7 Operation of space : Operates all luminaires bound within red dotted line - On, Off or im (up/down). Operation of space : ABCEF08 Operates all luminaires bound within green dotted line - On, Off or im (up/down). All areas: whilst both back rows follow whilst both back rows follow with a brighter offset with a brighter offset On vacation of each space any luminaires left on will switch off after an adjustable time-out period (default 0min). Space Space stage offset daylight linking - Referencing from the window row, both back rows will have a brighter offset. (offset value is adjustable).

6 Configuration Options Note: Many adaptions to each option are possible during setup. Please enquire if you can t find a configuration that exactly matches your specific requirements. Option 7: whilst both back rows follow with a brighter offset Space Space whilst both back rows follow with a brighter offset All areas: stage offset daylight linking - Provided this space is occupied, the window according to the natural light level detected, whilst the back rows will adopt a brighter offset (adjustable). Operation of Space : Operates channel and luminaires in this space - Off, On or im (Those bound within red dotted line) On entry of this space channel and luminaires switch on to maximum. On entry of only the adjacent space channel and luminaires switch to minimum (adjustable). On exit of this space (after time-out) but not adjacent space, channel and luminaires revert to minimum (adjustable). On exit of this space and adjacent space (after time-outs) channel and luminaires switch off. Operation of Space : Operates channel and luminaires in this space - Off, On or im (Those bound within blue dotted line) On entry of this space channel and luminaires switch on to maximum. On entry of only the adjacent space channel and luminaires switch to minimum (adjustable). On exit of this space (after time-out) but not adjacent space, channel and luminaires revert to minimum (adjustable). On exit of this space and adjacent space (after time-outs) channel and luminaires switch off. Option 8: Operation of Space : Space Space Config. 9 Option 9: See pages 0 & row daylight ABCEF Supplementary key Master On / Off / im up/down of all channels together Mode select - Channel Control OR Scene Control scene Scene setting Space Space Space Space All areas: All luminaires in this space daylight link at the same rate. On vacation of each space any luminaires left on will switch off after an adjustable time-out period (default 0min). Operates channel and luminaires in this space - Off, On (Those bound within red dotted line) On entry of this space channel and luminaires switch on. On entry of only the adjacent space channel luminaires switch on. On exit of this space (after time-out) but not adjacent space, channel luminaires switch off. On exit of this space and adjacent space (after time-outs) channel and luminaires switch off. Operation of Space : Operates channel and luminaires in this space - Off, On (Those bound within blue dotted line) On entry of this space channel and luminaires switch on. On entry of only the adjacent space channel luminaires switch on. On exit of this space (after time-out) but not adjacent space, channel luminaires switch off. On exit of this space and adjacent space (after time-outs) channel and luminaires switch off. Operation of Space : Operates all luminaires bound within red dotted line - On, Off or im (up/down). Operation of Space : Operates all luminaires bound within blue dotted line - On, Off or im (up/down). Operation of Space : Operates all luminaires bound within green dotted line - On, Off or im (up/down). Operation of Space : Operates all luminaires bound within purple dotted line - On, Off or im (up/down).

7 M Operates M Note: Our policy of continuous improvement means configurations may change from time to time. Please refer to data sheet for latest information. Option A: S Port A Config. 9 See pages 0 & ABCEF row daylight Scene setting Space Space Space Space Scene Setting Scene Setting Using the Flex Connectors scene setting panel (not supplied) with configuration Using the 9 Flex provides Connectors a scene setting scene solution setting that panel(not uniquely supplied) with offers offers the user the user two standard two standard modes of modes operation. of operation. Simply toggle Simply between toggle be either mode at any time. Operation [default] Operates all all luminaires - - On, Off, im (up/down) or rrecall/set up scenes up scenes - or - or toggle/dim channels - -. On On vacation vacation of of the the space space any any luminaires left left on on will switch off after an adjustable time-out period (default 0min). after an adjustable time-out period (default 0min). ther scene Space (Work station) Space (Notional Corridor) Option B: Config. B See pages & 5 Space Space Config. See pages 8 & 9 Space (notion corridor) ABCEF08 C C C C C C 9ABCEF08 Operation of Space : On entry of this space all luminaires switch on to maximum. On entry of any other space all luminaires switch on to Space (work station) Space (work station) minimum. Space (work station) On exit of this space (after time-out) but not any other space all luminaires revert to minimum (adjustable). On exit of this space and all the other spaces (after timeouts) all luminaires switch off. Config. F Space ABCEF08 Space (work station) Note: Configuration F is reserved for user specific As drawn no daylight solutions linking that when is required not in use but may is be an replaced available by the See pages option. & default configuration below. Space Operation of Space : Note: Please On entry refer of this to FSS0 space all INSTRUCTION luminaires switch (leaflet on to number /09) for o maximum. Table On entry of any Other other available space all operational luminaires variations switch to minimum. aylight linking not required anywhere. On exit of this space (after time-out) but not any other space all luminaires revert to minimum (adjustable). There On are exit more of this luminaires space and than all available the other output spaces sockets. (after timeouts) all luminaires switch off. The same type of switch operation is required at more than one point in t room. Provided this space is occupied, all luminaires daylight link according to the natural light level detected. There is insufficient occupancy coverage for the space. (range is typically 5.66m x 7.m per head) Operation Lights should of Space not only : switch off automatically when is vacated should On also entry turn of on this automatically space all luminaires on entry. switch on to The dimming maximum. protocol of the luminaires is SI and not ALI (or there is a mixture On of entry both). of any other space all luminaires switch on to minimum. This room On exit (and of this others?) space require (after time-out) an emergency but not test any switch other facility. space all luminaires revert to minimum (adjustable). This room On exit (and of this others?) space require and all a the last other man spaces out or (after all lights time-onouts) switch remote from all this luminaires area. switch off. Other As software drawn no adjustable daylight parameters linking is required not mentioned but is an available so far. option. Operation of Space : On entry of this space all luminaires switch on to maximum. On entry of any other space all luminaires switch on to minimum. On exit of this space (after time-out) but not any other space all luminaires revert to minimum (adjustable). On exit of this space and all the other spaces (after timeouts) all luminaires switch off. Provided this space is occupied, all luminaires daylight link according to the natural light level detected.

8 Configuration Options Note: Many adaptions to each option are possible during setup. Please enquire if you can t find a configuration that exactly matches your specific requirements. Option C: Operation of Space - Notional corridor: When unoccupied, occupancy in ANY other space switches luminaires to minimum (Set-back illumination). On specific entry of this notional corridor space the luminaires switch on to maximum. Space (work station) Space (work station) On exit of this notional corridor (after time-out) luminaires revert to set-back illumination. Only when ALL other spaces are unoccupied will the luminaires switch off (after time-outs). Operation of Space - Work station: els together ontrol scene Space (notional corridor) Config. E Space (notional corridor) Operation of Space - Work station: On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. As drawn no daylight linking is required but is an available option. Option : On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. As drawn no daylight linking is required but is an available option. Operation of Space - Notional corridor: When unoccupied, occupancy in ANY other space switches luminaires to minimum (Set-back illumination). On specific entry of this notional corridor space the luminaires switch on to maximum. On exit of this notional corridor (after time-out) luminaires revert to set-back illumination. Only when ALL other spaces are unoccupied will the luminaires switch off (after time-outs). Operation of Space - Notional corridor: On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. Space (Notional Corridor) Luminaires daylight link according to the natural light level detected. Space (work station) Space (work station) Space (work station) Operation of Space - Work station: On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. Luminaires daylight link according to the natural light level detected. Operation of Space - Work station: On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. Luminaires daylight link according to the natural light level detected. Operation of Space - Notional corridor: On entry of this or ANY other space all luminaires switch on. On exit of this and all other spaces (after timeouts) luminaires switch off. As drawn no daylight linking is required but is an available option.

9 Option E: Space (Work station) Space (notion corridor) Operation of Space - work station (default): On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. As drawn no daylight linking is required but is an available option. Operation of Space - notional corridor (default): On entry of this or ANY other space all luminaires switch on. On exit of this and all other spaces (after time-outs) luminaires switch off. As drawn no daylight linking is required but is an available option. Space (work station) Operation of Space - work station (default): On entry of this space luminaires switch on to maximum. On exit of this space (after time-out) luminaires switch off. stage daylight linking - The window row daylight whilst the back row adopts a brighter offset (adjustable). Option F: IMPORTANT: Configuration F is usually reserved for customised user specific configurations. On some occasions, when not required for this purpose a default configuration may be installed instead.

10 ZoneLite Occupancy Sensor Heads The PIR (passive infra-red) detector senses movement of warm bodies against a cooler background. The detection pattern is broadly rectangular at 7.m x 5.6m when fixed at a ceiling height of.5m (longest length of detection aligning with the spring clips). Occupancy Sensor Head fzh/pir (Master Head) The standard offering for straightforward occupancy sensing. Inbuilt infra-red receiver accepts commands from the ZoneLite hand held Remote Controls whilst an LE provides indication of operation. Requires a flex7 ZoneLite and Link Lead to operate. Occupancy Sensor Head with light level sensing fzh/pir/ls (Master Head) All the features of the fzh/pir but with the addition of a light cell for accurate lux readings under the head. Occupancy Slave Occupancy sensor head Sensor Head fzh/pir/sl (Slave Head) Up to 5 Slave Heads can plug-in in parallel with an existing Master Sensor Head (either of the above), increasing the detection range up to 6 fold. Each Slave Head comes with a Y adaptor to facilitate parallel connecting. Note: Slave Sensor Heads automatically adopt the same timeout that has been set on the existing Master Head they connect to. Light level sensing Head fzh/ls (Light Sensing Head) Optional light sensing head for use alongside fzh/pir/ls to average out Lux readings over greater areas. fzh/pir, fzh/pir/ls, fzh/pir/sl and fzh/ls (ordered separately). Includes x fixing screws Adaptor Plate Enables either of fzh/pir, fzh/pir/ls, fzh/pir/sl and fzh/ls heads to be surface mounted. Conduit box not supplied fnh/adapt

11 Scene Setting Panel The flex7 scene setting panel provides an advanced level of control for your lighting layout. Fits all standard 50mm x 50mm euro module front plates. Fast, easy and simple installation with RJ plug connection, plus the whole scene panel module snaps into location. Recalls up to different scenes. Set up/modify existing scenes directly from the front panel. Protect previously set up scenes with the inbuilt pin number. Available in black or white to suit your décor. Simple intuitive user operation. Our scene setting panel has been designed to complement the flex7 ZoneLite. The panel allows you to select scenes from tho se available with a flex7 ZoneLite, and instantly recall them with the simple press of a button. If needed, scenes can be further adjusted by dimming up/down individual channels, to create a tailor made lighting scene. Simple installation with one RJ plug. Available in black and white.. Recalls up to different scenes. Interfaces with the flex7 ZoneLite.

12 ZoneLite Remote Controls Two types of infra-red remote controls are available: A Setup Remote - to setup and optimize the sensor at or after installation and A User Remote - to offer the end user an additional level of control ZoneLite Setup Remote Control Sensor heads come factory set with a timeout of 0 minutes but for other timeouts, setting the light level, or setting up for other operational modes a Setup Remote control will be required. The ZoneLite Setup Remote Control allows the following parameters to be adjusted (depending on configuration):. imming control (manual/daylight dimming and daylight dependency).. etection type (absence/presence).. Sensitivity setting.. Timeout setting (default 0 mins). 5. imming load type (SI or ALI). 6. Offset dimming illumination levels. 7. Config. setting. 8. Set back illumination levels. User Remote Control Providing additional control for the end user it comes complete with its own holster with self adhesive pads ready for immediate attachment to wall, desk, computer etc. Can be used on any master sensor head to operate the lights on or off but is particularly suited to configurations controlling dimmable luminaires to provide dim up/down as well as the ability to store and recall up to 6 discreet light levels. fzl/rc 5.5 mm 6.0 mm frc/user 0.0 mm 8.0 mm

13 Ordering etails Ordering from the flex7 ZoneLite Range ZoneLite Lighting Control Units Type G (for general office environments) -Way, Channel, Type G 6-Way, Channel, Type G fzl0g fzl6g5 Note: the last numbers of the part number represent the number of outlets per channel. For example an fzl6g5 has outlets for ch, for ch, 5 for ch 0-Way, Channel, Type G fzl0g565 & for ch (alternative splits may be available on enquiry). ZoneLite Sensor Heads Master occupancy head Master occupancy head + light sensing fzh/pir fzh/pir/ls Use slave heads to increase the range of any master occupancy head up to 6 fold (5 max. can be connected in parallel to any Master). Each Slave occupancy head fzh/pir/sl slave head comes complete with a Y adaptor to facilitate parallel connecting. Light sensing head fzh/ls ZoneLite Remote Controls Setup Remote Control fzl/rc Note: At least one Setup Remote Control will be required for setting up your ZoneLite/s User Remote Control frc/user ZoneLite Remote Controls Scene Setting Panel Part Numbers flex7 Scene Setting Panel, Four Scenes, Module Only, White flex7 Scene Setting Panel, Four Scenes, Module Only, Black flex7 Scene Setting Panel, Four Scenes, Kit, White, White Plastic Frame flex7 Scene Setting Panel, Four Scenes, Kit, Black, Satin Steel Frame FSS0/M/W FSS0/M/B FSS0/K/W/WP FSS0/K/B/SS

14 Ordering flex7 Leads & Adaptors 05 5 metres 0 0 metres 5 5 metres 0 0 metres 0 0 metres 0 0 metres metres leave blank for pvc or add /lshf for low smoke halogen free cable leave blank or add /bl for link leads in blue. Note: All leads and adaptors operate at PELV (Protected extra low voltage) -Way, Channel, Link lead Type (-core) T fsl fzl0t (Grey cable) Use Note: to link the sensor last numbers leads to the of the ZoneLite part number or sensor to sensor represent (Master the to number Slave) of outlets per channel. For 6-Way, Channel, Type T fzl6t5 example an fzl6t5 has outlets for ch, for Switch drop lead (-core) fsw (Blue cable) Use ch, to connect 5 for ch wall & switches for ch (alternative to the ZoneLite splits to may be 0-Way, Channel, Type T fzl0t565 provide available local on switch enquiry). control Global switch drop lead (6-core) fnw (White cable) Use to connect wall switches to the ZoneLite to provide global switch control. ZoneLite Sensor Heads Network lead (6-core) fnl (White cable) Use to link between ZoneLites to provide common Master occupancy head fzh/pir control Use from slave a heads Global to Switch increase Input, the or range to connect of any a Master occupancy head + light sensing fzh/pir/ls series master of ZoneLites occupancy via head a Corridor up to Hold 6 fold Unit (5 max. to hold can escape be connected routes illuminated. in parallel to any Master). Each Slave occupancy head fzh/pir/sl slave head comes complete with a Y adaptor to facilitate parallel connecting. Y adaptors (-core) fsy/a For two connections into one - for use with -core Link leads or Switch drop leads only. ZoneLite Remote Controls Setup Network Remote Y adaptors Control (6-core) fny/a fzl/rc For Note: two connections At least one into Setup one Remote - for use Control with 6-core will be Network required leads for setting or Global up switch your ZoneLite/s drop leads only. User Remote Control frc/user Ordering flex7 Luminaire Connections For all Pre-wired Luminaire Leads, Plugs, ouble Extender Leads and any other parts not shown here, please refer to our main flex7 catalogue.

15 Technical ZoneLite Units 89.0 ZoneLite unit length way outlet: 5mm 6 way outlet: 65mm 0 way outlet: 75mm All measurements are in millimetres Rating Nominal 0V~ 6A, 50Hz, Class Manufactured in black PA6 UL9 V-0 rated, PC/ABS, and Anodised Aluminium. 7 contacts per outlet each rated at 6 amps, using the flex7 outlet format. Total system rating: 6A. Operating range: -0 C to 0 C IP0 Incoming terminals accept x.50mm², x.00mm² or x 6.00mm² conductors. Load (per channel) Fluorescent & incandescent lighting : 6A Compact fluorescent lighting : A Maximum number of ballasts (per channel): SI igital control : 5 ALI igital control : 5 Compliance: LV-006/95/EC & EMC-00/08/EC flex7 Sensor Link & Switch rop Leads fsl Length 8.9 XXm flex7 ZoneLite Occupancy Sensor Heads X etection Zone 6 discreet detection zones are acquired by the PIR detector. An object with a higher than background temperature will be detected if it moves between any two zones. Ø0.00 View X-X 5.0m.5m.5m 5.0m 50 O Suitable for snapping into a Ø mm cutout. All measurements are in millimetres 0 50 O m m Max. 7.m Y Y m Rating Supply Voltage: V C Manufactured in white & red PA6 UL9 V-0 rated, Non-halogen Compliance: LV-006/95/EC & EMC-00/08/EC Operating range: -0 C to 0 C Sensor Range: 7.m x 5.66m at.5m height X m X Y X Max. 5.66m etection Zone View Y-Y 5.0m.5m.5m 5.0m O O Y fsw XXm Lengths Comes in lengths up to 50 metres, refer to price list. Specification Connectors: PC modular jack, RJ style Conductor: Stranded Copper (PVC variant) Stranded Tinned Copper (LSHF variant) 8 a.w.g. Insulation: PP (PVC variant) PE (LSHF variant) Jacket: PVC (PVC variant) PE (LSHF variant) Standard IEC - (PVC variant) UL58 (LSHF variant) Insulation C 0 C: > 500MΩM Conductor C 0 C: < 7.0Ω/00M Rated Temperature: 70 C Rated Voltage: 500V

16 flex7 Networking Leads fnl XXm fnw XXm Lengths Comes in lengths up to 50 metres, refer to price list. Specification Connectors: 6PC modular jack, RJ style Conductor: Stranded Copper (PVC variant) Stranded Tinned Copper (LSHF variant) 8 a.w.g. Insulation: PVC (PVC variant) PE (LSHF variant) Jacket: PVC (PVC variant) PE (LSHF variant) Standard: IEC - (PVC variant) UL58 (LSHF variant) Insulation C 0 C: > 500MΩM Conductor C 0 C: < 7.0Ω/00M Rated Temperature: 70 C Rated Voltage: 500V Scene Setting Panel imensions Scene Setting Panel Technical Specification Input Supply: v C IP Rating: IP0 Manufactured in Black or White PVC

17 flex7 ZoneLite Type-T also available. A lighting connection & control solution in one, that comes preprogrammed with up to 5 distinct lighting configurations common to teaching and educational environments. Offering a prefabricated alternative to traditional wiring, the ZoneLite Type T is designed for use in educational environments. It provides options for absence/presence/daylight linking/graduated daylight dimming lighting control, independent switching of whiteboard or projector lights, emergency test, corridor hold, last man out switch and scene setting. Control up to lighting channels Available with, 6 or 0 outlets 5 preconfigured lighting layout options Contact us: You can order a ZoneLite Type-T Catalogue by ringing If you have any questions at all then please give us a ring / send us an / visit the website. info@flexconnectors.co.uk Tel: + (0)

18 Other products in the flex7 lighting connection and control range: The flex7 System is fully modular, and products simply plug-together. This results in huge reductions in installation time on site, and reduced requirements for skilled labour. The product range is split into three sections - Power up, Light up, and Control. Power up.. Provide power to your lighting circuit using flex7 ezeboxes, Single Socket Outlets or Hub Units. ezeboxes come in,, 6, 8, 0 and -ways and are 7-pole as standard. If you need to extend your circuit to add luminiares, simply plug an ezebox extender unit into your starter unit. Alternatively, if you want to add a separate circuit, plug-in an ezebox Tap-off Unit. Light up.. Connect your luminaires to the power supply using our extensive range of pre-wired luminaire leads. These can simply be plugged into any ezebox and Control We have a huge range of lighting controls available - all of which can simply be plugged into any ezebox. We offer occupancy/presence, absence, daylight linking, daylight dependency, manual dimming/switching and remote control. All controls operate at protected extra low voltage.

19

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

5 Linergy LED. Industrial. Mains lighting IP20

5 Linergy LED. Industrial. Mains lighting IP20 WARRANTY IP20 CONTROLS W A R R A N T Y YEAR Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of our highly efficient large space luminaires

More information

5 Linergy LED. Industrial. Mains lighting IP20

5 Linergy LED. Industrial. Mains lighting IP20 WARRANTY IP20 CONTROLS W A R R A N T Y YEAR Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of our highly efficient large space luminaires

More information

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when

More information

6 Linergy LED+ Industrial IP20 CONTROLS

6 Linergy LED+ Industrial IP20 CONTROLS WARRANTY IP20 CONTROLS W A R R A N T Y YEAR The is a premium, highly efficient version of the standard Linergy LED, designed to provide the same lumen values whilst using less power. The delivers even

More information

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting, Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting, heating and ventilation loads up to 10A installation

More information

To maximize energy savings in any type of buildings

To maximize energy savings in any type of buildings To maximize energy savings in any type of buildings THEY HAVE SPECIFIED AND INSTALLED ENERGY SAVING PRODUCTS: Diamond 2 & 3 Dubai Residence Evelyn Singapore The Soil Marine Bay Singapore Tribeca by the

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

HBDB High Bay Fixture with Occupancy Sensor

HBDB High Bay Fixture with Occupancy Sensor HBDB High Bay Fixture with Occupancy Sensor INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 20 feet. The fixture can be mounted with a hook or pendant

More information

Industrial Linergy LED

Industrial Linergy LED Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Electrak power track underfloor power distribution systems

Electrak power track underfloor power distribution systems 4 www.electrak.co.uk Electrak power track underfloor power distribution systems Tel: 01207 503400 Fax: 01207 501799 Email: sales@electrak.co.uk Because of our policy of continuous improvement, Electrak

More information

energy waste Putting a stop to

energy waste Putting a stop to Putting a stop to energy waste XX energy saving With lighting accounting for up to 20% of a commercial building s electricity use, the efficient control of lighting across all areas is a vital tool in

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

PULSE-8: MASTER PULSATION CONTROL

PULSE-8: MASTER PULSATION CONTROL PULSE-8: CONTROL Version - February 2006 For Software Version V1.02 Part Number - 39-0020 CONTROL: INDEX GOOD PRACTICE: Mains Supply. A separate mains supply and earth running directly from the consumer

More information

Catalog # Project. Comments. Prepared by. 6.4" [163 mm] Lumen Package Nominal per 4 section

Catalog # Project. Comments. Prepared by. 6.4 [163 mm] Lumen Package Nominal per 4 section DESCRIPTION The RZL is a suspended linear direct and semi-direct LED continuous row solution for new and retrofit construction. Designed for larger open ceiling environments, the RZL offers advanced LED

More information

INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING?

INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING? MAY 2018 ISSUE INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING? EXPERTISE, RELIABILITY, SUPPORT & FREE NEXT DAY DELIVERY s VALUE? Everyday Economy Lighting Competitive commercial offer Suitable for everyday

More information

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of

More information

GP12 TECHNICAL MANUAL

GP12 TECHNICAL MANUAL GP12 D i g i t a l l y C o n t r o l l e d D i m m e r R a c k TECHNICAL MANUAL Contents i Table of Contents Table of Contents... i 1.0 Introduction... 1-1 2.0 Equipment Description... 2-1 2.1 Front panel

More information

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.

More information

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format. PAGE 28 EMERGENCY EXIT SIGNAGE GUIDANCE All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format. 4 Our Eterna legends fulfil the legal and technical

More information

LEDSPOTS VOLTAGE-DRIVEN

LEDSPOTS VOLTAGE-DRIVEN LEDSPOTS VOLTAGE-DRIVEN CONVENIENT LED TECHNOLOGY As the perfect replacement for halogen lamps, these LED modules are ideal for use in furniture, false ceilings as well as cooker hoods. A wide product

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Operating Instructions

Operating Instructions Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Accessories (additional charge):

Accessories (additional charge): Alurail With Alurail, BOPLA has developed a modular DIN rail enclosure which is especially suitable for use in measurement, control and automatic control technology. Basic profiles, each in eight standard

More information

Distribution boards. 68 Q-DIN Range

Distribution boards. 68 Q-DIN Range Complete electric boards system for energy distribution in commercial, industrial and costrucion sites places. Available in both empty and wired version, in compliance with the IEC 61439 Standard: Versions

More information

Plug-in Dimmer Socket Kit

Plug-in Dimmer Socket Kit Plug-in Dimmer Socket Kit Model No. JSJSLW301 Instruction Manual Connect Series www.lightwaverf.house Version 2 EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham

More information

Norwich Hostry Norwich, UK. Downlight Lighting

Norwich Hostry Norwich, UK. Downlight Lighting Norwich Hostry Norwich, UK Downlight Lighting Contents RXS3 117 RXS Mini 120 Solstar Disk 122 VersaLux 12 Solstar LED 126 116 LIGHTING SOLUTIONS uk.eaton.com WARRANTY RXS3 RXS3 IP20 EM W A R R A N T Y

More information

The wide variety of systems for controlling and adjusting light brings great advantages:

The wide variety of systems for controlling and adjusting light brings great advantages: The wide variety of systems for controlling and adjusting light brings great advantages: Flexibility, light can be adjusted to any place or to any activity. ooks, lighting can be chosen to suit the surroundings.

More information

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of

More information

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX DG/S x DALI-Gateway Basic ABB i-bus KNX DG/S x.64.1.1 DALI-Gateway Basic The lamps are variably controlled via KNX per DALI output via Broadcast (all lamps jointly) 16 lighting groups 64 individual lamps 16 scenes 64 self-contained

More information

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) With central control inputs, front button and various operating modes and functions General purpose, user-friendly electronic pushbutton dimmer for

More information

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping.

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping. PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEW 3 5/8" 92mm 2 1/4 57mm ORDERING CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRODUCT SPECIFICATIONS 1 PRODUCT ID 2 OPTICS 3 LENGTH (FT)

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

ACCESSORIES - Electronic Daylight Switch - Cadmium Sulphide Daylight Switch Accessories 8.1 8.1 8.2 Daylight Switch Daylight Switch Daylight Switch D2 Wire-In PBL s 8.2 8.2 8.2 Docklite Docklite Light

More information

Power distribution components

Power distribution components Industrial electronics Power distribution components Reliable, cost-effective, complete R England sv_001.fm Rittal power distribution components Bar centre distance (mm) Number of poles Busbar dimensions

More information

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS. CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS www.legrand.co.uk POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall

More information

RUBIX RECESSED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

RUBIX RECESSED INTRODUCTION APPLICATION PRODUCT SPECIFICATION INTRODUCTION For premium office applications the Rubix Recessed brings a new level of style and functionality to the market. Nine individual cells with precise optical control allow for spacings up to three

More information

BH500 BH100 BH400 BH200 BH300 BH600 BH900 BH1100 BH700 BH1000 BH800. Series. Series. Series. Series. Series. Series. Series. Series. Series.

BH500 BH100 BH400 BH200 BH300 BH600 BH900 BH1100 BH700 BH1000 BH800. Series. Series. Series. Series. Series. Series. Series. Series. Series. Bulkheads BH100 Series BH200 Series BH300 Series BH400 Series BH500 Series LED Standard LED Anti-Tamper LED Utility Round / Square LED Slimline Full / Eyelid LED Diecast Full / Eyelid BH600 Series BH700

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM GENERAL REMARKS ON SAFETY: Read all of these instructions before installing fixtures. Keep all of the instructions for future reference. Turn off power before installing fixture. Installation is to be

More information

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No The Micro-Max is the smaller version of the Mini-Max, retaining the market leading features of the larger model. A prismatic diffuser gives an even light distribution from the energy efficient 2D lamp.

More information

Installation Instructions

Installation Instructions DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...43mA

More information

Snake Bus Power Distribution

Snake Bus Power Distribution Snake Bus Power Distribution ELECTRICAL CHARACTERISTICS Rated Current 50 Amps Rated Voltage 208Y/120 or 480Y/277 Volts Frequency 50/60 Hz Conditional Short Circuit Rating (Protection device) 16 KA Conductor

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Wireless Dimmer Installation and User Guide

Wireless Dimmer Installation and User Guide Installation Instructions Supported Models and Fixtures Wireless Dimmer Installation and User Guide This installation and user guide covers these dimmer models: LDZ-101-W Wireless Dimmer (802.15.4) LDZ-101-B

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines EM readyapply SELFTEST W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and

More information

smartest light Sicherheitstechnik GmbH

smartest light Sicherheitstechnik GmbH smartest light General information With the release of this catalogue all prior issued system-luminaire catalogues lose their validity. All products included in this release may vary, depending on technical

More information

Product Catalogue 2017

Product Catalogue 2017 Product Catalogue 2017 ULTRA SCREWLESS Deta Ultra Screwless is the ultimate metal plate range of wiring accessories, combining modern minimalistic styling with a screwless appearance. Ultra Screwless offers

More information

LCU DX Efficient cooling with no loss of space

LCU DX Efficient cooling with no loss of space LCU DX Efficient cooling with no loss of space 2 Cooling for network and server enclosures Space-saving installation of the internal unit between the 482.6 mm (19 ) level and side panel Optimum support

More information

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114 > As 1-, 2- oder 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 500 1400mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

Screed Floor system LIMOGES Cedex. Phone : Fax :

Screed Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 4 2.Installation process 5 to 10 3.Products details 11 to 24 4.Technical characteristics 25 to 26 1 RANGE. Optional

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation Reliant luminaires With 40% energy saving through cold cathode technology and 4 years maintenance free, Reliant luminaires offer incomparable benefits to the lighting designer. Easy first-fix installation

More information

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108 Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating

More information

VEROTEC Electronics Packaging

VEROTEC Electronics Packaging VEROTEC Electronics Packaging KM6-EC Subracks Introduction: KM6-EC Subracks Introduction KM6-EC subracks have been designed and are suitable for high volume, cost sensitive applications. Whilst they are

More information

LED SPOT. LEDSpot SmartLine SMD Furniture and Residential Lighting SMARTLINE SMD SMARTLINE SMD RECESSED MOUNTED LED SPOT

LED SPOT. LEDSpot SmartLine SMD Furniture and Residential Lighting SMARTLINE SMD SMARTLINE SMD RECESSED MOUNTED LED SPOT LED SPOT SMARTLINE SMD SMARTLINE SMD RECESSED MOUNTED LED SPOT As the perfect replacement for traditional halogen spotlights, these LEDSpots with an SMD LED are available with a round or square frame and

More information

Compact Sliding Door Operator Dor-O-Matic 2900 Series

Compact Sliding Door Operator Dor-O-Matic 2900 Series Uniclass L4181 EPIC D181 CI/SfB (31.59) X Compact Sliding Door Operator Dor-O-Matic 2900 Series June 2008 Compact Sliding Door Operator page 1 2900 Series Features & Functions Compact - Automatic Operator

More information

Let yourself be guided by the light

Let yourself be guided by the light DLP LED SYSTEM Let yourself be guided by the light The global specialist In ELECTrICAL AnD DIgITAL BuILDIng InFrAsTruCTurEs follow the light and move around intuitively The new multifunction illuminated

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the

More information

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron bus supplies (Eco-10 and Hi-lume

More information

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast IZT2S32SC 2 Lamp 32/T8 immable Ballast Philips Advance Catalog Number Manufacturer escription Weight per unit Product Category IZT2S32SC Philips Advance Electronic Ballast, High Frequency; Programmed Start;

More information

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting LEDAZ Solution meets clients every lighting requirement, covering a wide range of product portfolio including LED Reflector, LED Downlight, LED Tube, LED Plug-in Tube, LED Sensor Batten and LED Floodlight.

More information

Notes: 3 13/32. (5) Please consult factory (6) Available with T8 lamp only

Notes: 3 13/32. (5) Please consult factory (6) Available with T8 lamp only PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEWS Direct Indirect 3 13/32 ORDERING CODE 3 13/32 SHOWN WITH LENS OPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PRODUCT SPECIFICATIONS 1 PRODUCT

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and

More information

This catalogue is printed on FSC certified 100% recycled and chlorine-free paper.

This catalogue is printed on FSC certified 100% recycled and chlorine-free paper. PRODUCT CATALOGUE 2015 Published 2015. All rights reserved. This document was created by IED Greenpower S.L. and contains trademarks and other proprietary information. Due to a policy of continuous improvement,

More information

Central Battery Systems

Central Battery Systems Central battery system based emergency lighting is ideal for medium to large installations. For projects where central control and testing is desirable, a central battery system is a viable and cost effective

More information

RUNWAY SURFACE/SUSPENDED

RUNWAY SURFACE/SUSPENDED INTRODUCTION Where lighting must fulfill both architectural and practical purposes the Surface and Suspended Runway provides a slim line appearance with an anodised aluminium housing offering the versatility

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No Clean design lines give the Meridian range a leading edge for internal, easily maintained fittings. A straightforward design with a twist and lock diffuser means user-friendly maintenance and cost savings

More information

Product Catalogue August Energy management Switches and controls

Product Catalogue August Energy management Switches and controls Product Catalogue August 2015 Energy management Switches and controls Energy management Switches and controls Introduction Range overview Timers & Outdoor timers & Technical section Cable glands & terminal

More information

TEKMEC TEKMEC ABSOLUTE CONTROL PUSH BUTTON STATIONS PUSH BUTTON STATIONS - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE EC TI M I T ME PCMS

TEKMEC TEKMEC ABSOLUTE CONTROL PUSH BUTTON STATIONS PUSH BUTTON STATIONS - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE EC TI M I T ME PCMS ABSOLUTE CONTROL RF M EC TI NT PE CO TEKMEC TEKMEC ON TM TM M I T ME PCMS M11104IN (AN ISO 9001:008 CERTIFIED COMPANY) S - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE S SCOPE & SPECIFICATION

More information

Two lights are better than one. LUMILUX DUO

Two lights are better than one. LUMILUX DUO Two lights are better than one. LUMILUX DUO The power of two: LUMILUX DUO Elegant. Low-profile. Two lamps. This compact and extremely low-profile luminaire for fixed connection has a high-quality aluminium

More information

Museum Alkmaar - Alkmaar, Netherlands

Museum Alkmaar - Alkmaar, Netherlands Museum Alkmaar - Alkmaar, Netherlands 270 Lytespan 1 283 Lytebeam 287 Universal Suspensions TRACK 292 Nanotrack 1 267 TRACK Strellson - Moscow, Russia Construction: Total Max Load: Finish: Extruded aluminium

More information

19" front panels. Order Information. Delivery comprises (kit) Order Information. Note Please order assembly part kit separately.

19 front panels. Order Information. Delivery comprises (kit) Order Information. Note Please order assembly part kit separately. Cabinets 19" front panels There are three versions available 19" front panels (handles 2, 3 and 7 can be mounted) 19" blank panels 19" vented front panels 19" front panels The 19" front panels have additional

More information

With magnetic fixing With ON/OFF switch

With magnetic fixing With ON/OFF switch 7L Series - LED lamps 7L LED lamps for the cabinet Energy-saving (LED technology) Power consumption 5 W Luminous flux equivalent to a 95 W incandescent bulb Magnetic, screw or clip fixing With ON/OFF switch

More information

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply EM readyapply BASIC W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and battery

More information

RUNWAY CONTINUOUS RECESSED

RUNWAY CONTINUOUS RECESSED RUNWAY CONTINUOUS RECESSED PRODUCT SPECIFICATION INTRODUCTION Where lighting must fulfill both architectural and practical purposes the Recessed Runway provides a seamless appearance that can be infinitely

More information

SDGV LED. Device mount Product news for efficiency and technology. Made in Germany

SDGV LED. Device mount Product news for efficiency and technology. Made in Germany SDGV LED Device mount Product news for efficiency and technology Made in Germany SDGV LED the logical component of the already successful SDT system has been beefed up convert your SDT system to LED now

More information

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch switches, automatic switches 7 758 06 Aluminium finish 7 758 20 Aluminium finish 7 758 05 Aluminium finish 7 756 55 Pearl finish 7 756 57 Aluminium finish To be equipped with cover plates (p. 475 to 481)

More information

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency

More information

LED CANOPY with j-box

LED CANOPY with j-box ASD Garage Canopy Luminaire with junction box provides a slim, low profile solution for easy mounting. Built with rugged cast aluminum, this luminaire is available with surface or pendant mount. J-Box

More information

MK Electric IP Solutions

MK Electric IP Solutions MK Electric IP Solutions Masterseal Plus MK Shield IP56 MK Splashguard IP55 Thrives in the Toughest Conditions. MK Electric IP Solutions wiring devices ingress protected www.mkelectric.co.uk MK Electric

More information

Plug-in On/Off Socket Kit

Plug-in On/Off Socket Kit Version 2.1 Plug-in On/Off Socket Kit Model No. LW321 Instruction Manual Connect Series www.lightwaverf.house EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham

More information

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS 83 Mini-Lynx Sticks 86 Mini-Lynx Spirals 88 Power-Lynx 89 Mini-Lynx Classico 90 Mini-Lynx Compact GLS 91 Mini-Lynx Compact Ball 92 Mini-Lynx Candle 93 Mini-Lynx Globe 94 Mini-Lynx Reflectors 96 Mini-Lynx

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Pressure Sensors. for liquid and gaseous media

Pressure Sensors. for liquid and gaseous media 1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature

More information