CENTRAL ADAPTER KIT INSTALLATION manual
|
|
- Jason Sutton
- 6 years ago
- Views:
Transcription
1 CENTRAL ADAPTER KIT INSTALLATION manual EPURAIR MA-1 HEPA AIR FILTRATION SYSTEM
2 Epurair MA-1 - Central Application Installation Manual PAGE 2 Included In the CONVERSION kit METAL SCREWS x 4 WOOD SCREWS x 2 ADAPTER PLATE (FACTORY INSTALLED ON THE MA-1C) WALL mounting BRACKET x 1 UNIT BRACKET x 1 RUBBER STANDS x 4 NOT Included In the kit 8 INCHES SIDE TAKEOFF WITH DAMPER x 1 6 INCHES SIDE TAKEOFF x 1 ROLL OF DUCT TAPE 8 INCHES FLEXIBLE CONDUIT* 6 INCHES FLEXIBLE CONDUIT* * Rigid conduits can also be used but make sure that there is enough clearance to the top (see step 5) to service the unit.
3 PAGE 3 OVERVIEW OF THE FINISHED INSTALLATION 8 INCHES SIDE TAKEOFF WITH DAMPER 8 INCHES FLEXIBLE CONDUIT WALL BRACKET AIRFLOW AIR EXIT FURNACE AIR ENTRANCE 6 INCHES FLEXIBLE OR RIGID CONDUIT 6 INCHES SIDE TAKEOFF
4 PAGE 4 1- CONVERTING THE PORTABLE UNIT UNSCREW AND REPLACE THE LOUVER GRILL WITH THE PROVIDED CENTRAL ADAPTER PLATE (IF CONVERTING FROM PROTABLE MODEL) 2- REPLACING OR INSTALLING THE RUBBER FEET REMOVE WHEELS AND INSTALL THE RUBBER STANDS (IF CONVERTING FROM PROTABLE MODEL) X 4 X 4
5 PAGE 5 3- LOCATING AND CUTTING HOLES INTO THE DUCTS AIR EXIT AIRFLOW 8 INCHES SIDE TAKEOFF OPENING LOCATED UPSTREAM OF AIRFLOW (OPENING SIZE MAY VARY ACCORDING TO YOUR SIDE TAKEOFF MODEL SPECS.) IMPORTANT: 4 FEET MINIMUM DISTANCE BETWEEN THE TWO OPENINGS FURNACE AIR ENTRANCE 6 INCHES SIDE TAKEOFF OPENING LOCATED DOWNSTREAM OF AIRFLOW (OPENING SIZE MAY VARY ACCORDING TO YOUR SIDE TAKEOFF MODEL SPECS.) 4- INSTALLING THE SIDE TAKEOFF AIRFLOW IMPORTANT: INSTALL DAMPERED SIDE TAKEOFF BY MAKING SURE THE DAMPER IS CORRECTLY ORIENTED TO CATCH AND DIVERT THE AIRFLOW TO THE MACHINE. INSTALL REMAINING SIDE TAKEOFF AND FLEXIBLE CONDUITS LEAVING ENOUGH LENGTH SO THE HEPA UNIT CAN REST ON THE FLOOR WITHOUT PUTTING ANY STRAIN ON THE CONDUITS.
6 PAGE 6 5- LOCATING THE WALL MOUNTING BRACKET IF SUSPENDED ON THE WALL ALLOW 18 IN. OF CLEARANCE WITH OVERHEAD OBSTACLES TO ALLOW INSPECTION OF THE UNIT WITHOUT UNHOOKING IT FROM THE WALL IMPORTANT: ALLOW ENOUGH CLEARANCE SO THERE WILL BE NO KINKS IN THE CONDUITS ONCE THE UNIT IS HOOKED ON THEWALL 6- INSTALLING THE WALL MOUNTING BRACKET USING THE TWO WOOD SCREWS FIX THE WALL MOUNTING BRACKET. BE SURE TO SCREW INTO A WALL STUD OR INTO A SOLID UNDERBACKING LIKE CONCRETE
7 PAGE 7 7- INSTALLING THE MOUNTING BRACKET ON THE HEPA UNIT If you decide to hang THE UNIT to THE wall BRACKET CAN BE INSTALLED LEFT OR RIGHT ALIGN TOP OF BRACKET WITH THE TOP OF UNIT COVER 6-3/4 FROM BACK USE THE 4 PROVIDED METAL SCREWS TO FIX THE BRACKET TO THE UNIT NOTE : Although the unit is meant to be hung some people leave it on the floor when they are unable to find a wall close enough.
8 PAGE 8 8- CONNECTING THE HEPA UNIT AND SEALING THE JOINTS FIX THE CONDUITS ON THE HEPA UNIT AND HOOK IT ON THE WALL BRACKET SEAL ALL OPENINGS WITH GOOD QUALITY DUCT TAPE
9 PAGE 9 9- Finishing the installation PLUG THE UNIT DIRECTLY IN A 3 PIN GROUNDED ELECTRICAL OUTLET WITHOUT USING ANY EXTENTION CORD TURN THE SPEED SELECTOR TO YOU R DONE
10 PAGE 10 BLANK
11 PAGE 11 BLANK
12 Epurair inc. 149 J.-A.-Bombardier street Boucherville (Quebec) J4B 8P1 Canada Toll Free: Epurair has the right to change any speci ication without notice Epurair MA1 Central EN Printed in Canada Racycled Paper
JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market
1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter
More informationPreparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range
Electrical Requirements IMPORTANT: Observe all governing codes and ordinances. (Please consult with a qualified electrician for 220-Volt 50 Hz voltage) It is the customer s responsibility: To contact a
More informationAMBIENT AIR FILTRATION IN THE WOODSHOP. By Lou Gatch
AMBIENT AIR FILTRATION IN THE WOODSHOP By Lou Gatch Dust in the woodshop is a serious problem that should be addressed. The air we breathe during our activity in the shop is not totally removed by the
More informationProduct Manual MNX10015 / REV B MODEL SB142, SB242. Dual Output Series Switch Boxes
Product Manual MNX10015 / REV B MODEL SB142, SB242 Dual Output Series Switch Boxes Contents Section I Overview Introduction.... 2 Description... 2 Section II Installation Mounting... 3 Electrical Connections...
More informationMANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1
More informationOne Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and
More informationINSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD
More informationVOC Duct and Rough Service Sensor
Overview and Identification Humans respirate Volatile Organic Compounds (VOCs) as well as CO 2. The BAPI sensor measures these VOCs and indicates space occupancy just as well as a CO 2 sensor. The advantage
More informationInstallation Instructions
Installation Instructions Speedcook Oven Read carefully. Keep these Instructions. INSTALLATION INSTRUCTIONS Electrical Requirements Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MODELS 600HS, 1200HS, 2000HS PLUS HVAC 600HS L Housing 600HS S Housing 1200/2000HS S Housing 1200/2000HS L Housing 1 ASSEMBLY INSTRUCTIONS HVAC VERSION STEP 1. STEP 2. STEP 3.
More informationINSTALLATION INSTRUCTIONS UNDER CABINET HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationCharcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st
Venting Methods This range hood is factory set for venting through the roof or wall. For non-vented (re-circulating) installations, see Ductless Conversion on Page 7. Vent work can terminate either through
More informationTORi INSTRUCTION SHEET. Minimalist Linear Fixture T5/T5HO. CSS - Cable Suspended. 1. Cut cables to desired length - take care not to fray cable ends.
TORi Minimalist Linear CSS - Cable Suspended J-BOX (BY OTHERS) 3-O or 4-0 MUD RING (BY OTHERS) J-BOX BRACKET BAR 1/4-20 STUD 8-32 BRACKET BAR SCREWS (BY OTHERS) CANOPY STND - 5 CANOPY 1. Cut cables to
More informationLaboratory Exhaust Air Terminal
Document No. 546-00335 Laboratory Exhaust Air Terminal Product Description The Laboratory Exhaust Terminal (LGE) is a onepiece flow control device used to vary airflow through an exhaust duct. See Figure
More informationINSTALLATION INSTRUCTIONS UNDER CABINET HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALL SERVICE- ENTRANCE SYSTEMS
SUBCOURSE EN5141 EDITION B US ARMY ENGINEER SCHOOL INSTALL SERVICE- ENTRANCE SYSTEMS INSTALL SERVICE- ENTRANCE SYSTEMS Subcourse Number EN5141 EDITION B United States Army Engineer School Fort Leonard
More informationIQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual
IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The
More informationOWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT
OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Features Long-life, Certified True HEPA (High Efficiency Particulate Air) Filter is
More informationPRODUCT OVERVIEW.
PRODUCT OVERVIEW www.weldco-hydralift.com CONTENTS WHL23TC60/75/100...4 HL30TC70...8 OUR PRODUCTS Weldco Hydra-Lift manufactures truck mounted telescopic cranes ranging from 23-ton to 50-ton capacities.
More informationINSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD
More informationWall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style
Wall Mount Chimney Style Island Mount Chimney Style Wall Mount Professional Style Insert Mount Professional Style 2 3 Installation: 4 Table of Contents Wall Hood Installation Island Installation Professional
More informationMODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER
MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit
More informationAIR FILTRATION DEVICE
AIR FILTRATION DEVICE Operating instructions (ENG) MODEL: 10079020 Read these instructions before using the machine. 86337980-F 01/12/12 Machine Data Label Overview The Triad AFD (Air Filtration Device)
More informationNJK Precision Product NJK-02 Sensor Installation Guide
Precision -02 Sensor 2017 Product Line Precision Product Table of Contents Precision Company Overview - Page 2-02 Installation Guidelines - Page 3-02 Recommended Installations - Page 5-02 Non-Recommended
More informationINSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More information564 Shadowbox Face (w Screen) Instructions
Packing List Compatibility Face Bottom Shield (2) Face Brackets (8) Screws (#8 x 3/8 Phillips) (5) Screws (#8 x 5/8 hex head) Drill Template 11/64 Drill Bit Items Used with Optional Switch Box (see note
More informationINSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES
More informationINSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationPreventative Maintenance
Preventative Maintenance ECLIPSE and ECLIPSE 2 2 Oxygen Systems Models 1000 & 1000A 102008 Expectation: Complete PM schedule for Eclipse devices Detailed technical information and data for Eclipse devices
More informationCHAPTER 21 ENVIRONMENT CONTROL. Section Title Page
CHAPTER 21 ENVIRONMENT CONTROL Section Title Page 21-00 Description........................................ 21.1 21-10 Ventilation........................................ 21.3 21-11 Nose Vent................................
More informationOne Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation
More informationTABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.
TABLE OF CONTENTS PAGE SPECIFICATIONS 3 INSTALLATION 4 Direct Mount 4 Ducted Installations 5 Installing Plenum 5 Machine Mount Stand 5 Ceiling Mount 6 Pedestal Stand 7 Drain Installation 7 Electrical 8
More informationINSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationINSTALLATION AND OPERATING INSTRUCTIONS
COLEMAN -MACH AIR CONDITIONERS INSTALLATION AND OPERATING INSTRUCTIONS CHILLGRILLE DIRECT AIRFLOW REPLACEMENT CEILING ASSEMBLY PART NUMBER 7330-6331 FOR 6727, 6799 AND 7000 SERIES AIR CONDITIONERS DESIGNED
More informationINSTALLATION INSTRUCTIONS WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -
More informationINSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO
More informationEGG CRATE RETURN GRILLE
80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders
More informationINSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO
More informationInstallation Instruction
T F W 604.549.9379 604.549.9555 fluxwerx.com Installation Instruction DRIVER ENCLOSURE Ceiling Type Version Grid Battery Pack GRID MOUNT INSTALL OPTIONS OPTION 1: Standard Vertical Grid drivers can be
More informationZ22C-** Preconfigured Network Zone System
Z22C-** Preconfigured Network Zone System Page 1 of 12 TABLE OF CONTENTS Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting Removable
More informationPHOENIX MINI-GUARDIAN
PHOENIX MINI-GUARDIAN H. E. P. A. SYSTEM Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Table of Contents PHOENIX MINI-GUARDIAN
More information5. Contractor Information 3M Model 2300 Series System Layout Checklist
5. Contractor Information 3M Model 2300 Series System Layout Checklist This checklist contains the information necessary to provide the environment required to successfully install your new Model 2300
More informationSS820R SAFARI R-SPEC SNORKEL SUZUKI JIMNY 1.3L 4 Cylinder Petrol (G13B & M13A Engines)
SS820R SAFARI R-SPEC SNORKEL SUZUKI JIMNY 1.3L 4 Cylinder Petrol (G13B & M13A Engines) Parts List 01/04/2015 ITEM PART NO DESCRIPTION QTY 1 930-133-000R BODY - SNORKEL 1 2 000-135-400 3 " AIR RAM ASSEMBLY
More informationCRITICAL ENVIRONMENT DIFFUSERS
READ COMPLETELY AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CRITICAL ENVIRONMENT DIFFUSERS SSLF, SSLFHFD, FRD, FRD-HEPA, HRDP, HRDP- HEPA, SSHEMI, SSHEMI-HEPA INSTALLATION AND SERVICE MANUAL THESE
More informationOVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS
OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS Please read all instructions thoroughly before installing the Over the Range Microwave Oven/Hood System. Two people are recommended to install this
More informationWire Mesh Grip Families
Wire Mesh Grip Families Complete offering of wire mesh grips built tough for industrial applications Arrow Hart supplies a broad selection of strain relief, pulling and support grips in a wide range of
More informationJACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017
JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017 JEA SHALL MAKE ALL METER SPOTS BEFORE ELECTRICAL WORK BEGINS AS TO DETERMINE THE POINT OF ATTACHMENT
More informationINSTALLATION INSTRUCTIONS K SERIES LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationAMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation
2004 Americair Corporation, Mississauga, Ontario, Canada AIR CLEANERS/ FILTERS AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS FOR MODELS AWW-350, AWW-675,
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationBinding Finisher. Installation Procedure
Binding Finisher MB-000C-NA MB-000C-EU Installation Procedure When installing this product, follow these instructions. (Make sure to perform the actual work with at least 2 people.) NOTE : THE FINISHER
More informationTotal comfort control
Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data
More informationOperating Manual MAC-21 VFD
Operating Manual MAC-21 VFD Portable Filtration Module Part Number FM37VFD Master Contract No. 215873 Certificate No. 2449861 Class 3812-81 Fans and Blowers Class 3812-01 Fans and Blowers 860.445.0334
More informationINSTALLATION / OPERATION / MAINTENANCE GUIDE
INSTALLATION / OPERATION / MAINTENANCE GUIDE WHOLE HOUSE HEPA FILTRATION SYSTEMS MODEL HS 3.0 Table of contents About Us Imperial Air Technologies Inc.is the only manufacturer that offers you a complete
More informationINSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation
More informationINSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationbrisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:
brisas by Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number: SEP08.0101 Zephyr Corporation SAFETY NOTICE... 2-3 LIST OF MATERIALS...
More informationOVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS
OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS Please read all instructions thoroughly before installing the Microwave Oven/Hood System. Two people are recommended to install this
More informationP&G MANUFACTURING INC.
P&G MANUFACTURING INC. Bag-In/Bag-Out Operation and Maintenance Manual Table of Contents SECTION PAGE Manufacture s Message 3 Introduction 4 Handling and Storage of Filter Elements 9 Installation of New
More information#366. Gate Operator Pre-Installation and Site Planning. Introduction
Gate Operator Pre-Installation and Site Planning Introduction Although each manufacturer s equipment has unique design characteristics and functions, gate operators are somewhat similar in many installation
More informationHow to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1
Seth Johnson How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 History: A man named John Whitehurst first created the Hydraulic Ram Pump in 1772. That means that this ingenious
More informationINSTALLATION MANUAL HYDRAULIC HOSE REEL
INSTALLATION MANUAL HYDRAULIC HOSE REEL 1 TABLE OF CONTENTS SECTION PAGE SECTION PAGE 1 HOW TO ORDER PARTS 3 MAINTENANCE SCHEDULE... 11 1.1 HOW TO ORDER PARTS... 2 1.2 MODEL IDENTIFICATION... 3 2 INSTALLATION
More informationSafety & Installation Instructions
Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting
More informationINSTALLATION, OPERATION & MAINTENANCE INSTRATIONS
INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS (27/6/13) Contents 1. GENERAL DESCRIPTION... 2 2. RECEIPT AND PREPARATION... 2 3. INSTALLATION... 2 3.1. REMOVAL OF ACCESS PANEL... 2 3.2. FIXING A PLINTH...
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More informationPressure Independent Flow Controller
protected Pressure Independent Flow Controller SkoFlo Valve Model SF10000NB OPERATION AND MAINTENANCE INSTRUCTIONS 10/30/2002 protected SkoFlo Valve Model SF10000NB OPERATION AND MAINTENANCE INSTRUCTIONS
More informationTable of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5
-02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4
More informationHandling Arm CHANGING CABLE PROCEDURE USER GUIDE
Handling Arm CHANGING CABLE PROCEDURE USER GUIDE Table of Contents 1. Installation Procedure...1 2. Wire Replacment Procedure...11 3. Contact Us...16 Installation Procedure 1 1. 2. 3. 4. 5. Determine the
More informationProduct Manual MNX10043 REV 0 MODEL DSB. Dual Sensor Modular Switch box
Product Manual MNX10043 REV 0 MODEL DSB Dual Sensor Modular Switch box Contents Section I Overview Introduction..... 2 Description 2 DSB Model Selection.. 2 Section II Installation Mounting Instructions....
More informationHigh Power GFCIs FEATURES GFCI Volts/Amps: 240V/40A. Trip Level: 4-6 ma. Single Phase GFCI Volts/Amps: 120V/30A
High Power GFCIs High Power GFCIs Has 2 of cable on both line and load side. Will remain reset on power restoration following disruption of primary power. Auto reset. 23250 003-1 GFCI Volts/Amps: 240V/40A
More informationCONVECTOR HEATING REV. 4 ROSEMEX PRODUCTS HEATING
CONVECTOR ROSEMEX PRODUCTS REV. 4 2018 TYPE WF WALL TYPE This wall-hung convector-radiator is ideal where floors require frequent cleaning. The cabinet is screwed or bolted to wall, depending on its construction,
More informationVertical Cable Organizer with Finger Ducts - 0U - 3 ft.
Vertical Cable Organizer with Finger Ducts - 0U - 3 ft. Product ID: CMVER20UF This 3-foot vertical cable manager gives you a simple and space-efficient way to organize the cables in your server rack. You
More informationModel CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I
Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings
More informationPatent Pending EXTENDED-DUTY PISTON PUMP
TM Patent Pending EXTENDED-DUTY PISTON PUMP O p e r a t i o n & I n s t a l l a t i o n M a n u a l P/N 95222 Rev. 9-29-9 4 2 6 psi 9 1 12 16 14 2 4 6 8 1 INCHES W.C. 4 2 6 N psi IN 1 12 16 14 EXTENDED-DUTY
More informationOWNER S MANUAL. Installation and Service Manual
OWNER S MANUAL Blue OX1050P Series Installation and Service Manual INTRODUCTION FEATURES AND SPECIFICATIONS SAFETY WARRANTY UNPACKING / INSTALLATION OPERATION MAINTENANCE REPLACEMENT PARTS TROUBLESHOOTING
More informationSOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216
SOLAR-150HD 150-Watt Dual Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 731-5869 FAX 904 733 0012 Toll Free 800-684-6404 TABLE OF CONTENTS Page
More informationInstallation Instructions Table of Contents
Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft
More informationLLOYD INDUSTRIES INC.
1-1/2 HOUR FIRE/SMOKE DAMPER FIRE/SMOKE DAMPER VERTICAL OR HORIZONTAL MOUNT 1-1/2HR RATING (Bi-Directional) (For use in 2hour or less rated partitions) Located in pin grooves. Minimum Size Single Section
More informationFlowCon Fabric Air Diffusers
FlowCon Fabric Air Diffusers 204 Hallberg St. PO BOX 507 Delavan, WI. 53115 Installation, Operation and Maintenance Manual Project Title: Location Name: Date: Service Contractor: Telephone Number: CONTENTS
More informationAir Quality Solutions
Air Quality Solutions Installation & Maintenance Manual Model: EAMP Electronic Air Measuring Probe with EAMP020 Electronic Controller II-EAMP-815/Replaces II-EAMP-615 ALL STATED SPECIFICATIONS ARE SUBJECT
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 28-Jan-16 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More informationHBDBM High Bay Series
HBDBM High Bay Series INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 25 feet. The fixture can be mounted with a hook or pendant with flexible adjustments
More informationInstallation instructions, accessories - Fuel driven heater 912-D
XC90 Section Group Weight(Kg/Pounds) Year Month 8 87 2002 10 XC90 2003 D5244T, XC90 2004 D5244T, XC90 2005 D5244T AW50/51 AWD, XC90 2006 D5244T, XC90 2006 D5244T AW50/51 AWD D5244T R8703687 Page 1 of 20
More informationINSTALLATION INSTRUCTIONS ISLAND LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationModel DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating
Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be
More informationTable of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5
-02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4
More informationRM-1200 Slim Round Control Damper
RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality
More informationSECTION VII METERING INSTALLATIONS
SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND
More information2011 Mercedes-Benz C350 Sport
Fig. 3: Identifying Seat-Back Lining, Tabs And Guides Model 207, 204.3 shown with front seat removed Fig. 4: Identifying Seat-Back Lining, Tabs And Screws Remove/install 1.1 Adjust left or right front
More informationINSTALLATION MANUAL 2000WCY
INSTALLATION MANUAL 2000WCY Pressure Cleaning System spraymastertech.com Spray Master Technologies is a quality product line of Assembled Products Corp. 115 E. Linden Rogers, Arkansas 72756 USA (479) 636-5776
More informationFan Powered Low Profile Variable Volume Terminal Units
MANUAL INSTALLATION Fan Powered Low Profile Variable Volume Terminal Units FEVLP / FPVLP / FDVLP Series v001 Issue Date: 07/19/16 07/19/16 Price Industries Limited. All rights reserved. TABLE OF CONTENTS
More informationModel VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.
Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationModel VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.
Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted
More informationEnclosure and Facility Design Guidelines for Recycling and Trash Removal Service. Santa Barbara, CA Updated November 2014
Enclosure and Facility Design Guidelines for Recycling and Trash Removal Service Santa Barbara, CA Updated November 2014 Front End Loading Containers Enclosures:. A. Enclosures should be designed with
More informationOperations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD
Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD ----------------------------------------------------------------We Make Clean Air----------------------------------------------------------------
More information