High Power GFCIs FEATURES GFCI Volts/Amps: 240V/40A. Trip Level: 4-6 ma. Single Phase GFCI Volts/Amps: 120V/30A
|
|
- Hillary Walker
- 5 years ago
- Views:
Transcription
1 High Power GFCIs High Power GFCIs Has 2 of cable on both line and load side. Will remain reset on power restoration following disruption of primary power. Auto reset GFCI Volts/Amps: 240V/40A Cord Gauge: 8/3 AWG Trip Level: 6 ma GFCI Volts/Amps: 120V/30A Cord Gauge: 10/3 AWG Trip Level: 4-6 ma C US GFCI Trip Level: 4-6 ma
2 Heavy Duty - High Power ELCIs 30A Heavy Duty - High Power ELCIs - 30A Has 2 of cable on both line and load side. Will remain reset on power restoration following disruption of primary power ELCI Volts/Amps: 240V/30A ELCI Coleman Cable Inc
3 Heavy Duty - High Power ELCIs 60A Heavy Duty - High Power ELCIs - 60A Has 2 of cable on both line and load side. To prevent equipment startup after ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power Volts/Amps: 120V/60A Cord Gauge: 4/3 AWG Volts/Amps: 240V/60A Volts/Amps: 380V/60A Trip Level: 30 ma RESET TEST
4 Heavy Duty - High Power GFCI/ELCI Adjustables Heavy Duty - High Power GFCI/ELCI Adjustables Has 2 of cable on both line and load side. To prevent equipment startup after GFCI/ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power key enables trip level selection and locking at a trip level with key removal Volts/Amps: 277V/30A Cord Gauge: 10/3 AWG Volts/Amps: V/60A Volts/Amps: 480V/30A Volts/Amps: 480V/60A Cord Gauge: 8/5 AWG RESET TEST Coleman Cable Inc
5 RESET safety products Heavy Duty - High Power GFCI/ELCI Adjustables with Trip Level Selector Heavy Duty - High Power GFCI/ELCIs with Trip Level Selector TRC has engineered a new option for the HD-PRO series called Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PRO with key enables trip level selection and locking at a trip level with key removal. Protects: Portable Conveyors Pressure Washers Freight Lifts Volts/Amps: 480V/100A Cord Gauge: 2/4 AWG Volts/Amps: V/80A Volts/Amps: 480V/80A Volts/Amps: 600V/60A Volts/Amps: 600V/80A Volts/Amps: 600V/100A Cord Gauge: 2/4 AWG BLACK 3/ TESTBLACK RESET TEST BLACK BLACK 3/
6 High Power Equipment Ground Fault Protective Devices (EGFPD) and GFCI/ELCI Adjustables To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power. Key enables trip level selection and locks at a trip level with key removal. safety products High Power Equipment Ground Fault Protective Devices (EGFPD) and GFCI/ELCI Adjustables EGFPD* EGFPD* Volts/Amps: V/60A EGFPD* Volts/Amps: 480V/30A EGFPD* Volts/Amps: 480V/60A * GFCI/ELCI GFCI/ELCI Volts/Amps: V/60A GFCI/ELCI Volts/Amps: 480V/30A GFCI/ELCI Volts/Amps: 480V/60A C US user attachable NEMA 4 16 gauge steel Front View Allowed space for conduit attachment holes Bottom View Allowed space for conduit attachment holes Right Side View PANEL MOUNT STUDS, Coleman Cable Inc
7 Wiring Instructions for High Power GFCI/ELCIs All high power GFCI/ELCIs must be suited for use with solidly grounded systems. The power cords must be connected according to the wiring instructions shown below. WIRING INSTRUCTIONS 120V, 277V UNIT 240V 1 UNIT 208/240V 3 UNIT* 208/480/600V 3 UNIT 1. Black = Line 2. White = Neutral 3. Green = Ground 1. Black = Line 2. Red (Pink) = Line 3. White = Neutral 4. Green = Ground 1.Black = Line 2.Red (Pink) = Line 3.Orange (Blue) = Line 4.White = Neutral 5.Green = Ground 1.Black = Line 2.Red (Pink) = Line 3.White = Line 4.Green = Ground CIRCUITRY TYPE Single Phase Type A V = 120 V = 277 Single Phase Type B V = 240 Three Phase Type C V = 208 / / 600 Three Phase Type D V = 208 / / 600 Grounding Point May Vary * 34
Electrical Safety Products for Construction, Manufacturing and Industrial Maintenance
Electrical Safety Products for Construction, Manufacturing and Industrial Maintenance 2010 Table of Contents Ground Fault Circuit Interrupters (GFCI) Shock Shield Plug-In Portables..........................................
More informationSection Index Portable GFCI Right Angles In-Lines Duplex & Quad Boxes Right Angle & In-Line Quad Boxes User Attachables ELCIs & PRCDs
Coleman Cable, along with its subsidiary Technology Research Corporation (TRC), has an extensive line of electrical safety products that ensure protection from dangerous current leakage that can cause
More informationASSEMBLED. Coleman Cable Inc
ASSEMBLED 800-323-9355 www.colemancable.com For over 40 years, Coleman Cable (CCI) has been a leader in the development of innovative wire and cable products. Today we re utilizing more than 2 million
More informationPreventing Electrocutions and Injury with Industrial GFCIs. White Paper
Preventing Electrocutions and Injury with Industrial GFCIs White Paper Introduction Hundreds of people in the United States are killed by electricity every year, and several times that number are shocked
More informationThese devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series
PGFM Series GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore
More informationModel 550 Series Vibration Switches
OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...
More informationPB-Series. GFCI/ELCI & Panel Seal
PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationMF /MS Series
MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationSURE-TRIP OEM RELACEMENT TRIP UNIT
RMS CURRENT MEASUREMENT with SURE-TRIP OEM RELACEMENT TRIP UNIT Update Circuit Breaker Solid State Controls with SURE-TRIP LOGIC The SURE-TRIP Solid State Tripping Systems Have Been Designed, Tested And
More informationVisit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS
AMR INC. DESIGN & MANUFACTURING FOR MINING WORLDWIDE P.O. BOX 234, ROCKY GAP, VA 24366 PHONE (276)928-1712 FAX (276)928-1814 Email sales@americanmineresearch.com Visit our web site at www.americanmineresearch.com
More informationDatasheet AC Outlet DIN-Rail Mountable Receptacles
Datasheet AC Outlet DIN-Rail Mountable Receptacles DIN-rail receptacles, 5A, 15A and 20A power outlets, provide a convenient power source for portable computers or test devices for in-the-panel troubleshooting.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More informationSURE TRIP RETRO KITS
RMS CURRENT MEASUREMENT with SURE TRIP RETRO KITS Circuit Breaker Solid State Controls with SURE TRIP LOGIC The Sure Trip Solid State Tripping Systems Have Been Designed, Tested And Produced To all Applicable
More informationDuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating
General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return
More informationBRAVO Inverter/Battery Charger. Table of Contents
BRAVO 1050 Inverter/Battery Charger Table of Contents Introduction... 2 General Description... 2 Specifications... 3 Installation: Hardwire Units... 4 Operation: Hardwire Units... 5-6 Installation: GFCI
More informationA 120V BR GFI Recpt. Features. Material, Color, and Finish. Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 2095 20A 120V BR GFI Recpt. Pass & Seymour/Legrand Catalog Number 2095 Manufacturer Pass
More information1333 (SERIES B & C) TROUBLESHOOTING GUIDE
1333 (SERIES B & C) TROUBLESHOOTING GUIDE Preventive Maintenance: Problems with Your Drive? Bulletin 1333 is convection or fan cooled by air flowing through the heat sink slots. The slots must never be
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these
More informationModel (Circuit Tester) Model (GFCI Tester)
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Receptacle Testers Model 20250-61 (Circuit Tester) Model 20250-62 (GFCI
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationWF-5110R True Sine Wave Inverter
Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationValcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual
Valcom Failsafe Unit 1620ESv2 SERIES Operation and Maintenance Manual Table of Contents Section Title Page 1. - Introduction.. 2. - Unpacking the Failsafe unit. 3. - Installation 3.1 - Auto / Timed UPS
More informationPART B BRAND SPECIFIC MANUAL
SPA OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS PART B BRAND SPECIFIC MANUAL ELECTRICAL CONNECTION KEYPAD OPERATION 200 Series 200-M-B-16 Read in conjunction with Part A General Manual to form a complete
More informationELECTRICAL GROUNDING SAFETY PROGRAM
ELECTRICAL GROUNDING SAFETY PROGRAM PURPOSE / SCOPE The purpose of this program is to ensure the proper installation, maintenance, inspection, and testing of equipment grounding conductors on construction
More informationOpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary
Document No. 155-785 OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary Description The OpenAir direct coupled enhanced non-spring return rotary electric actuators are designed
More informationWF-5110R True Sine Wave Inverter
Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION
More informationDemand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!
Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning
More informationSPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 2095TRWRI 20A 125V Spec TR & WR Gfci Rec Pass & Seymour/Legrand Catalog Number 2095TRWRI Manufacturer Pass & Seymour/Legrand
More informationBBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER
BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER Important The BBC -3140 must be used according to the local safety standards with the particular application. All wiring and connections
More informationGA PLUS Ordering Information. Earth Leakage Motor Protection Relay Kits
PLUS Ordering Information Earth Leakage Motor Protection Relay Kits About The NewElec Earth Leakage relay provides earth leakage protection also known as ground fault protection designed to protect personnel
More informationOwner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:
POWER SOLUTION www.jtbmfg.com Owner s Manual JTB Manufacturing, Inc. Part No. 2010-100 Manufacture Date Year: 2013 Month: Serial Number Electrical Ratings 120VoltAC, 1 Phase, 50/60 Hz, 20 AMP Type 1 Enclosure
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationMore innovative solutions for an ever-evolving world. Electric Vehicle Chargers
More innovative solutions for an ever-evolving world. Electric Vehicle Chargers Reliable EV charging solutions from an electrical innovator you can trust. Electric vehicles (EVs) are hitting the road in
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationElectric Actuator Instructions
BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationTechnical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators
OpenAir GQD Series Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled
More informationPressure Control Type KPU
MAKING MODERN LIVING POSSIBLE Data sheet Pressure Control Type KPU KPU controls are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or
More information7. SERVICES OVER 600 VOLTS
7. SERVICES OVER 600 VOLTS 7.1 GENERAL The Company shall always be consulted to obtain required design criteria where service is contemplated.preliminary plans of the Customer shall be submitted for review
More informationIQC IQC IQC
IQ SERIES Industrial Quasi Sine Wave AC Power Inverter Models IQ12-2600 IQ12-3600 IQC12-2600 IQC12-3600 IQC24-3600 Owners Manual IQ SERIES OWNERS MANUAL 1/0 Wire Minimum 1/0 Wire Minimum Typical Static
More informationVCPR. A Portable Device for Remotely Racking VCP-W Circuit Breakers. User s Manual
VCPR A Portable Device for Remotely Racking VCP-W Circuit Breakers User s Manual MarTek Ltd. RAKTEK User s Manual Model VCPR 1.0 Arc-blast Hazards 2.0 Application Information 3.0 General Safety Information
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationPBA Series Prelube Controls
VARNA Products Engineered Innovation PBA Series Prelube Controls Simple, Compact, Industrial Full featured control for running prelube from the control or from a remote station Easy internal wiring connections
More informationAn average of one worker is electrocuted on the job every day There are four main types of electrical injuries:
Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock
More informationFACT SHEET Standard: Electrical Safety
What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationJandy Pro Series WaterColors LED Lights Underwater Large and Small Light
installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified
More informationTRAVEL CORDSET AND WALL STATION TEST REPORT
GENERAL MOTORS TRAVEL CORDSET AND WALL STATION TEST REPORT REVISION 4 EVSE Model: Click here to enter text. Serial Number: Click here to enter text. Test Engineer: Click here to enter text. Date: Click
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationVCPR. User s Manual. MarTek Ltd. RAKTEK. Model VCPR. A Portable Device for Remotely Racking VCP-Style Circuit Breakers 1.0 Arc-blast Hazards
VCPR A Portable Device for Remotely Racking VCP-Style Circuit Breakers 1.0 Arc-blast Hazards MarTek Ltd. RAKTEK User s Manual Model VCPR 2.0 Application Information 3.0 General Safety Information 4.0 Cables
More informationVM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)
Installation Guide VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) VICPA222 Technical Data Power 24 Vac ±20%, 50/60 Hz Power consumption 8 VA (running)
More informationDSR1. User s Manual. MarTek Ltd. RAKTEK. Model DSR1. A Portable Device for Remotely Racking DS and DSII-Style Circuit Breakers. 1.0 Arc-blast Hazards
DSR1 A Portable Device for Remotely Racking DS and DSII-Style Circuit Breakers 1.0 Arc-blast Hazards MarTek Ltd. RAKTEK User s Manual Model DSR1 2.0 Application Information 3.0 General Safety Information
More information702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS
702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...
More informationXP600/1100/2000 INSTALLATION AND OPERATION MANUAL
7317 Jack Newell Blvd North Fort Worth, Texas 76118-71 817-595-4969 voice, 817-595-129 fax 8-886-4683 toll free website wwwexeltechcom Manufacturer of UL Listed Products Copyright 21 Exeltech Inc All rights
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationINSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationSection 8 Stab-lok Circuit Breakers
Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationROTARY Point Level Measurement for Inventory Control
Measure. Detect. Alert. ROTARY Point Level Measurement for Inventory Control Detect high and low levels while protecting valuable inventory with tried-and-true rotary level indicators from BinMaster. Made
More informationInstallation Instructions
30RAP010-150, 38APS05-065, 38APD05-130 Ground-Fault Interrupter Convenience Outlet Accessory Installation Instructions Part No. 30RA-900---058, 30RA-900---059 SAFETY CONSIDERATIONS Installation of this
More informationSieve Shaker 200mm/300mm - 8/12 inch SV003
Sieve Shaker 200mm/300mm - 8/12 inch SV003 CONTENTS Introduction Specification Installation Controls Operation Maintenance Spares and Accessories 1 Introduction The unique action of this Sieve Shaker (Fig
More informationMaster/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control
Document No. 129-312 Master/Slave Actuators Spring Return Rotary 24 Vac - Modulating Control a PL0038R1 c b d e f g i Figure 1. Parts of the Master/Slave Actuators. h a. Actuator b. Shaft adapter c. Position
More informationApplication Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.
Application Guide 575-012 Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1 Carlyle Controller Part No. 2BSB000928 1 General Description The PCM is part of Paragon Compressor
More informationINSTALL CIRCUIT PROTECTIVE DEVICES
SUBCOURSE EN5146 EDITION B US ARMY ENGINEER CENTER AND SCHOOL INSTALL CIRCUIT PROTECTIVE DEVICES INSTALL CIRCUIT PROTECTIVE DEVICES Subcourse Number EN5146 EDITION B United States Army Engineer School
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationPRODUCT INFORMATION BULLETIN
724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery
More informationPhase-Adaptive Power Module with 3-Wire Fluorescent Input
369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic
More informationThis is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationELECTRICAL SYSTEM RP-7
ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three
More informationPure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A
Pure Sine Wave Power Inverter SSW-350-12A SSW-600-12A SSW-1000-12A SSW-1500-12A SSW-2000-12A Owner's Manual Please read this manual before installing your inverter 1 IMPORTANT SAFETY INSTRUCTIONS THIS
More informationSUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More information3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube
3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two
More informationInstallation and Service Manual for Residential Series EVSE (Electric Vehicle Supply Equipment)
Supersedes August 2012 (Electric Vehicle Supply Equipment) Contents Description Page Installation guide.... 2 Important safety instructions please read... 2 Symbols and definitions... 2 About the charging
More informationContacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON
Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions
More informationPressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials in contact with medium... 3 Technical data... 4 Ordering...
More informationTOTALINE PROTECTION CONTROLS
TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients
More informationReproduction. Not for ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM
ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM FILE IN: INTEK & VANGUARD REPAIR MANUAL GFCI Inverter Stator POWERLINK Harness Reset ON OFF Switch
More informationPAGE Both power cords must be connected & powered to operate the E-TES 120.
PAGE 1 This document outlines questions to ask and components to check during E-TES 120 troubleshooting. More detailed troubleshooting procedures are available in the E-TES 120 Troubleshooting Guide. 1.
More informationELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4
More informationElectric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2011 Class 2800 CONTENTS Description............................................ Page 3 Catalog Numbering
More informationOpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc
Technical Instructions Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct
More informationSmartX MF and MS
schneider-electric.com 1 SmartX MF41-6043 and MS41-6043 Non-Spring Return Direct-Coupled Actuators Figure-1 Parts of the SmartX Rotary Actuator Product Description These installation instructions describe
More informationOperating Instructions
DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,
More informationQuarter Master Series 94 Actuator
Quarter Master Series 94 Actuator Installation, Operation and Maintenance Manual Assembly Series 94 Manual Rev V 9/5/13 Page 1 of 12 Table of Contents Series 94 Electric Actuator Introduction... 3 Description...
More informationELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
HVAC/BAC ELECTRIC IOM ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS Electric Actuator Specifications... 2 Overview... 3 Actuator
More informationSPECIAL-PURPOSE GFCI FOR INDUSTRIAL APPLICATIONS SB6100. Industrial
SPECIAL-PURPOSE GFCI FOR INDUSTRIAL APPLICATIONS SB6100 Industrial The Only Special-Purpose 1. NEMA 4X Enclosure Prevents access to hazardous parts and provides protection against water, humidity and corrosion.
More informationMULTI-PROCESS POWER FOR HEAVY DUTY APPLICATIONS
FLEXTEC 650X MULTI-PROCESS POWER FOR HEAVY DUTY APPLICATIONS Shown: K3425-1 SIMPLE. RELIABLE. FLEXIBLE. This multi-process welder delivers up to 815 amps of welding power for a variety of applications,
More informationTable of Contents. For latest version, visit:
Table of Contents 1.0 Introduction... 1.0 Overview... 1 3.0 Test Set Controls... 6 3.1 Power... 6 3. Time Display... 6 3.3 Timer Clear Push Button... 6 3.4 Start Push Button and LED... 6 3.5 Stop Push
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationQuest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:
Quest Dry Quest H5 Read and Save These Instructions This manual is provided to acquaint you with the Quest H5 air mover so that installation, operation and maintenance can proceed successfully. Ultimate
More informationElectrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1
Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)
More informationSwitching Power Module
369357d 1 06.20.13 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic