Vacuum generator. Operating instructions a [ ]

Size: px
Start display at page:

Download "Vacuum generator. Operating instructions a [ ]"

Transcription

1 Vacuum generator OVEM- -LK en Operating instructions a [ ]

2 Original instructions OVEM- -LK-DE Identification of hazards and instructions on how to prevent them: Warning Hazards that can cause death or serious injuries Other symbols: Note Material damage or loss of function Recommendations, tips, references to other documentation Text designations: Activities that may be carried out in any order 1. Activities that should be carried out in the order stated General lists Result of an action/references to more detailed information 2 Festo OVEM- -LK 1702a

3 1 About this document Product description Structure Characteristics Safety Use for intended purpose General safety information Range of applications and certifications Function and application Function overview Switching functions Valve control Air-saving function Monitoring and diagnostics Measured variables Teach function (Teach-In) Data storage (Data Storage) Block parameterisation Parameter description General instructions, IO-Link Identification parameters Process data (Process data) Smart Sensor profile parameters (Smart Sensor Profile Parameters) Device parameters (Device Parameters) Observation parameters (Observation Parameters) Diagnostics (Diagnosis) Device commands (Device Commands) Installation Mechanical Pneumatic Electrical Commissioning Commissioning vacuum generator Adjusting intensity of the ejection pulse Festo OVEM- -LK 1702a English 3

4 8 Operation Operating manual override Restore factory settings Activating security code Error messages and fault clearance Status messages Diagnostic levels Error messages and error codes Malfunctions Disassembly Maintenance and care Technical data Appendix Graphic display and LCD displays Operating statuses and menu structure Meaning of symbols for representing the menu structure RUN mode SHOW mode Edit mode Teach mode Festo OVEM- -LK 1702a English

5 1 About this document This document describes the use of the above mentioned product. All available documents for the product 2 Product description 2.1 Structure ab aa 7 aj Ejector pulse solenoid valve (Eject) 2 Vacuum solenoid valve 3 Mechanical manual override of the solenoid valves 4 Supply port (1) 5 Exhaust port / silencer (3) 6 Vacuum connection (2) 7 Housing with mounting holes Fig. 1 Control sections and connections 8 Slide for changing the filter element 9 Filter housing with inspection window aj Flow control screw for adjusting the ejector pulse aa Vacuum sensor with LCD display and operating keys Fig. 13 ab Electrical connection Festo OVEM- -LK 1702a English 5

6 2.2 Characteristics Characteristic Code Meaning Vacuum generator OVEM Vacuum generator with vacuum solenoid valve ON/OFF and electric manual override Nominal width of laval nozzle mm mm mm mm mm Vacuum type -H High vacuum -L High suction volume Housing size / width -B 20 mm wide, ISO standard Pneumatic ports -QS All ports with QS push-in fittings -QO Supply / vacuum port with QS push-in fittings, exhaust port with open silencer -GN All ports with G female thread -GO Supply / vacuum port with G female thread, exhaust port with open silencer -PL Prepared for manifold rail, vacuum and exhaust port with QS push-in fittings -PO Prepared for manifold rail / vacuum port with QS push-in fittings, exhaust port with open silencer Normal position of the vacuum -OE NO, normally open (vacuum generation) with ejector pulse generator -CE NC, normally closed (no vacuum generation) with ejector pulse Electrical connection -N Plug M12 (5-pin) Vacuum sensor -LK IO-Link Alternative vacuum display - Bar -H InHg Tab. 1 Overview of variants 6 Festo OVEM- -LK 1702a English

7 3 Safety 3.1 Use for intended purpose The vacuum generator type OVEM-...LK is designed for generating a vacuum. 3.2 General safety information The product may only be used in its original status without unauthorised modifications. Only use the product if it is in an excellent technical status. Use the product only inside buildings. Take into consideration the operating conditions at the location of use. The product is intended for use in industrial environments. The product can generate high frequency interference, which may make it necessary to implement interference suppression measures in residential areas. Observe the specifications on the product labelling. Comply with all applicable national and international regulations. Observe the local specifications for environmentally friendly disposal. 3.3 Range of applications and certifications Note CE Declaration of Conformity 4 Function and application 4.1 Function overview The OVEM-LK is a vacuum nozzle with digital transmission of setpoint and actual value as well as diagnostics and parameterisation options. Communication takes place in the IO-Link mode. SIO mode is supported. IO-Link parameters and functions in accordance with Smart-Sensor profiles Chapter 5. 2 binary data channels for programming switching functions and switching behaviour. SIO mode: Local configuration via the operating keys. In the SIO mode, OVEM has the function of a 2P variant (1 switching input, 2 switching outputs). Festo OVEM- -LK 1702a English 7

8 Functions: Control of the compressed air supply with 2 valve functions Chapter 4.3 Auto-Drop function: generation of an automatic eject pulse for accelerated vacuum purging and safe set-down Chapter 4.3 Air-saving function Chapter 4.4 Electrical and mechanical manual override Chapter 8.1 Monitoring of vacuum build-up through integrated pressure sensor. If the setpoint value is reached, or if it is not reached due to malfunctions (e.g. leakage, dropped workpiece), the vacuum generator emits an electrical signal and a status message. Prevention of vacuum purging through internal check valve if vacuum generation is interrupted. Data storage and expanded monitoring function. 4.2 Switching functions The binary outputs can be configured via the switching functions. The switching status information is thereby made available at the electric port as a process value or binary signal. IO-Link mode: 3 BDC (binary data channels), bit 0: BDC1 or BDC2, bit 1: BDC3 Chapter 5.3 SIO mode: 2 switching outputs Out A and Out B The switching logic of the binary outputs can be configured as normally open (NO) or normally closed (NC). The switching mode of the binary outputs can be determined as threshold value or window comparator. Threshold value comparator Normally open (NO) Normally closed (NC) Switching function 1 Switchpoint (SP1) Teach mode 1) : 2 Teach-in points (TP1, TP2) SP1 = ½ (TP1+TP2) OUT 1 0 1) TP1 = smaller pressure value, TP2= larger pressure value, independent of the Teach sequence Tab. 2 Threshold value comparator: setting of switchpoint SP1 and hysteresis HY HY TP1 SP1 TP2 p OUT 1 0 HY TP1 SP1 TP2 p Window comparator Normally open (NO) Normally closed (NC) Switching function: OUT OUT 2 switchpoints (SP1, SP2) 1 HY HY 1 HY HY Teach mode 1) : 2 Teach-in points (TP1, TP2) 0 TP1=SP1 TP2=SP2 p 0 TP1=SP2 TP2=SP2 p 1) TP1 = smaller value, TP2 = larger value, independent of the Teach sequence Tab. 3 Window comparator: setting of switchpoints SP1, SP2 and hysteresis HY 8 Festo OVEM- -LK 1702a English

9 4.3 Valve control Depending on the input signal, the vacuum solenoid valve or the ejector pulse solenoid valve is controlled. IO-Link mode: 2 BCS (binary control signals), bit 0: BDC1, bit 1: BDC2 Chapter 5.3 SIO mode: 1 switching input DI1 (Z BCS1). Switching input positive switching (PNP) Auto-drop function: The ejector pulse is generated after the signal change Suction (BCS1). The pulse length can be set through the parameter Auto-Drop time Tab. 10. Valve function OVEM-...-CE Auto-drop active Auto-drop inactive Auto-Drop t ab Auto-Drop t ab 5 Valve function OVEM-...-OE Auto-drop active Auto-drop inactive Auto-Drop t ab Auto-Drop t ab 5 1 Control signal BCS1 / switching input DI1 2 Control signal BCS2 3 Vacuum solenoid valve switching status Fig. 2 Valve control switching behaviour 4 Ejector pulse solenoid valve switching status 5 Vacuum connection (2) t ab Duration of ejector pulse Festo OVEM- -LK 1702a English 9

10 4.4 Air-saving function The air-saving function reduces air consumption during the evacuation phase. 50 mbar (fixed) t BCS1/DI1 BDC1 t t 1 Hysteresis (HY) 2 Threshold value Switch off suction = switchpoint (SP1) 3 Threshold value Switch on suction 4 Reset point (RSP1) Fig. 3 Mode of operation of the air-saving function If the pressure value has reached the switchpoint SP1 2, vacuum generation is deactivated. A an internal check valve prevents the reduction of the vacuum. Vacuum can still be reduced slowly due to leakage in the overall system (e.g. due to rough workpiece surfaces). To reduce energy consumption, vacuum generation is not switched on until the lower threshold value 3 is fallen below. This procedure runs as long as the control signal is present at BCS1/DI1. The air saving function is activated in the factory. 4.5 Monitoring and diagnostics The vacuum generator has monitoring functions that permit early detection of malfunctions or errors in ongoing operation. Monitoring of process parameters (pressure value at the vacuum connection, limit values of binary data channels, evacuation time t E, air supply time t B ). Error detection and diagnostic messages Chapter 9 The monitoring functions are activated at the factory (except for monitoring of the evacuation and air supply times). The time monitoring can be activated through setting of the limit values SP1 (evacuation time) and SP2 (air supply time) in BDC4 Tab. 9. The switching status information of the BDC4 is not included in the process input data (Process data IN). 10 Festo OVEM- -LK 1702a English

11 4.6 Measured variables Pressure value (vacuum) The pressure value (vacuum) is continuously measured between the vacuum connection and filter. The minimum and maximum measured pressure values are saved. If the operating voltage of the vacuum generator is switched off, these values are reset. Cycle time A cycle covers the time from the start of evacuation through ejection to the start of the new evacuation. Evacuation time and air supply time The evacuation time t E is measured from the start of evacuation until reaching of the switchpoint SP1 by BDC1 or BDC2. The air supply time t B is measured from the start of air supply to the time at which the pressure value (vacuum) falls below 50 mbar. p Cycle time 1 50 mbar 0 2 t t E Transport time t B Return time BCS1/DI BDC1 or BDC2 / Out A Vacuum valve Ejector pulse valve 1 Switchpoint SP1 (BDC1 or BDC2) t E 2 Reset point RSP1 (BDC1 or BDC2) t B Fig. 4 Clock cycle (example for Out A (Air-save)) Evacuation time Air supply time Festo OVEM- -LK 1702a English 11

12 4.7 Teach function (Teach-In) The Teach function permits configuring the switchpoints and time monitoring during run time. Static Teach-In Depending on the Teach command, a switchpoint (SP) is determined from one or two teach-in points. The switchpoints are determined statically, that is, the measurement value remains constant during the entire Teach-In procedure. During execution of the Teach-In procedure, the air save function is deactivated for the duration of the procedure. Teach commands Tab. 15 Simplified Teach commands BDCx Start (Teach Start), BDCx Stop (Teach Stop) can be used independently of the switching function. The sequence of the teach-in points must be taken into account. For all commands, first the desired channel must be selected. Dynamic Teach-In Setpoint values are calculated within the Teach-In procedure from a time period. The procedure is used for determination of evacuation and air supply times Fig. 5. After the start of the Teach-In, the time t E and t B is measured at each cycle. With multiple cycle times, the times are averaged. After the stop of the Teach-In, a function reserve of 100 % is added to the averaged values. p SP1 50 mbar Teach Start t E1 1 tb1 2 t E2 t B2 Teach Stop t Vacuum valve t 1 Transport time 2 Return time Fig. 5 Dynamic mode of operation Teach-In 3 Cycle time 1 4 Cycle time 2 5 Cycle time N 12 Festo OVEM- -LK 1702a English

13 4.8 Data storage (Data Storage) The data storage mechanism (DS) permits consistent and updated saving of device parameters to higher levels, such as PLC programs or fieldbuses. Changes of the parameters are messaged by the vacuum generator to the IO-Link Master, which then fetches the parameter, saves it in a higher-level system and makes it available to the new device if the vacuum generator is replaced. Parameters that can be saved Chapter 5 The data storage mechanism is supported at the device, but is administered by the application (IO-Link master). 4.9 Block parameterisation Block parameterisation permits uniform access to parameters over multiple indexes or subindexes as well as transfer of entire parameter sets. Transfer of block parameters through start and end commands Tab. 15 During transfer, parameter changes (e.g. through Teach-In) are blocked. In case of an invalid parameter set, the changed parameters are discarded and the previous parameter set is reactivated. Festo OVEM- -LK 1702a English 13

14 5 Parameter description Note Related device description file (IODD) For detailed information on the IO-Link specification and for the Smart Sensor Profil General instructions, IO-Link Characteristic Specification Protocol version Device V1.1 Profile Smart Sensor Profile Function classes Tab. 9 Communication mode COM2 (38.4 kbaud) Port class A Process data width IN 2 bytes Tab. 7 Process data content IN 2 bit BDC (pressure monitoring), 14 bit PDV (pressure measurement value) Process data width OUT 1 byte Tab. 8 Process data content OUT 1 bit (vacuum ON/OFF), 1 bit (ejector pulse ON/OFF) Block parameterisation Supported Data memory required 0.5 KB Minimum cycle time 3.5 ms SIO mode support Yes Tab. 4 General instructions (general IO-Link specification) 5.2 Identification parameters Identification direct parameters (Identification Direct Parameters) Index Name Value Description Information 0x07 VendorID1 (MSB) 0x01 Manufacturer identification R 0x08 VendorID2 (LSB) 0x4D 0x09 DeviceID1 (MSB) 0x00 Device identification 0x0A DeviceID2 0x00 0x0B DeviceID3 (LSB) 3C Device variant OVEM-...-H-...-OE 3D Device variant OVEM-...-L-...-OE 3E Device variant OVEM-...-H-...-CE 3F Device variant OVEM-...-L-...-CE 1) R = read Tab. 5 Identification direct parameters (Identification Direct Parameters) 14 Festo OVEM- -LK 1702a English

15 Identification device parameters (Identification Device Parameters) Index Subindex Name Value Description Information 0x Vendor Name Festo AG & Co. KG Manufacturer name R 0x Vendor Text Includes additional information 0x Product Name e.g. OVEM-05-H-B-QO- CE-N-LK Complete order code of the product 0x Product ID e.g. OVEM-H-CE Device variant/type designation 0x Product Text Vacuum generator Device characteristic 0x Serial Number XXXXXXXXXXX Product key 0x Hardware Revision 0x Firmware Revision 0x Application SpecificTag e.g REV00101 e.g. V Part number and revision status of the product Firmware version of the device *** Application-specific marking, can serve as functional identification. 1) R = read, R/W = read and write, FR = factory reset (Factory Reset), DS = data storage (Data Storage) possible Tab. 6 Identification device parameters (Identification Device Parameters) R/W FR DS 5.3 Process data (Process data) Process input data (Process data IN) Bit 15 (MSB) 2 (LSB) 1 0 Process data 1) Process Data Variable (PDV) BDC3 BDC1/BDC2 2) Data content 1) Pressure Value 3) Out B Out A (Air-save) / Out A 1) R = read 2) Assignment of the BDC is dependent on the parameter Air-saving function: Air-save ON = BDC1, Air-save OFF = BDC2 3) Current pressure value (pressure value) standardised and scaled to 14 bit. Formula: p2 = pressure value*(1000 mbar/16383) Tab. 7 Process input data (Process data IN) Process output data (Process data OUT) Bit 15 (MSB) 2 (LSB) 1 0 Process Data 1) Reserved BCS2 2) BCS1 3) Data content 1) Reserved Drop Vacuum 1) W = write, no data storage (Data Storage) 2) Values: BCS2 = 0: ejector pulse solenoid valve not switched, BCS2 = 1: ejector pulse solenoid valve switched 3) Values: BCS1 = 0: vacuum solenoid valve not switched, BCS1 = 1: vacuum solenoid valve switched Tab. 8 Process output data (Process data OUT) Festo OVEM- -LK 1702a English 15

16 5.4 Smart Sensor profile parameters (Smart Sensor Profile Parameters) Index Name Value Description Length (byte) 0x000D 0 Profile List of profile identifiers 12 R 1 Characteristic 0x0001 Smart Sensor Profile 2 2 0x8000 Device Identifikation 2 3 0x8001 Binary data channel (BDC) 2 4 0x8002 Process data variable (PDV) 2 5 0x8003 Diagnostics 2 6 0x8004 Teach channel 2 0x000E 0 PD Input Data structure of the process input data 6 1 Descriptor 0x BDC1, BDC x020E02 Process data variable (pressure) 3 0x000F 0 PD Output Data structure of the process output data 3 1 Descriptor 0x BCS1, BCS2 3 0x003A 0 Teach-In channel 0x003B 0 Teach-In Status 1 Teach flag TP2 for SP2 2 Teach flag TP1 for SP2 3 Teach flag TP2 for SP1 4 Teach flag TP1 for SP1 0 Standard value; BDC1 with activated air-saving function (Air-save = ON); BDC2 with deactivated air-saving function (Air-save = OFF) 1 BDC1 (Out A Air-save) 2 BDC2 (Out A) 3 BDC3 (Out B) 4 BDC4 (Monitoring of evacuation time/air supply time) 0 Current status of the activated Teach-In channel 0 Teach point TP2 for SP2 not taken over 1 Teach point TP2 for SP2 taken over 0 Teach point TP1 for SP2 not taken over 1 Teach point TP1 for SP2 taken over 0 Teach point TP2 for SP1 not taken over 1 Teach point TP2 for SP1 taken over 0 Teach point TP1 for SP1 not taken over 1 Teach point TP1 for SP1 taken over 5 Teach state Current status of the Teach-In 1) R = read, W = write, R/W = read and write, DR = device restart (Device Reset) DS = data storage (Data Storage) possible Subindex Information 1) 1 R/W DR DS 1 R DR 16 Festo OVEM- -LK 1702a English

17 Index Name Value Description Length (byte) Subindex Information 1) BDC1 - Out A (Air-save) air-saving function (Air-saving function) 0x003C 0 Setpoint SP (0-1 bar) Lower switchpoint Standard values: OVEM-...-L: 6553 (-0.4 bar) OVEM-...-H: (-0.7 bar) 1 Setpoint SP2 0 Upper switchpoint Standard value: 0 0x003D 1 Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis (0-0.9 bar) BDC2 - Out A 0x003E 0 Setpoint SP (0-1 bar) 1 Setpoint SP (0-1 bar) 0x003F 1 Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis (0-0.9 bar) Switchpoint logic 1 0 NO (Standard) 1 Switchpoint logic NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard value: 4096 (0.25 bar) Lower switchpoint Standard values: OVEM-...-L: 6553 (-0.4 bar) OVEM-...-H: (-0.7 bar) Upper switchpoint Standard values: OVEM-...-L: (-0.67 bar) OVEM-...-H: (-0.97 bar) Switchpoint logic 1 0 NO (Standard) 1 NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard value: OVEM-...-L: 1638 (0.1 bar) OVEM-...-H: 4096 (0.25 bar) 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2 R/W FR DS R/W FR DS 2 2 Festo OVEM- -LK 1702a English 17

18 Index Name Value Description Length (byte) BDC3 - Out B 0x Setpoint SP (0-1 bar) 1 Setpoint SP (0-1 bar) 0x Switchpoint logic 2 Switchpoint mode 3 Switchpoint hysteresis 0x Setpoint SP1 (evacuation timeout) 1 Setpoint SP2 (ventilation timeout) (0-0.9 bar) Lower switchpoint Standard values: OVEM-...-L: 3227 (-0.2 bar) OVEM-...-H: (-0.5 bar) Upper switchpoint Standard values: OVEM-...-L: 6717 (-0.41 bar) OVEM-...-H: (-0.71 bar) Switchpoint logic 1 0 NO (Standard) 1 NC Switchpoint mode 1 1 Single point mode (Standard) 2 Window mode Hysteresis value Standard values: OVEM-...-L: 1638 (0.1 bar) OVEM-...-H: 3227 (0.2 bar) Subindex Information 1) 2 R/W FR DS BDC4 - Evacuation time t E and air supply time t B (Time monitoring evacuation/ventilation) Evacuation time limit value t 2) E ( ms) Standard: 0 0x Switchpoint logic 0x Switchpoint mode 3 Switchpoint hysteresis ( ms) Air supply time limit value t B 2) Standard: 0 Switchpoint logic of the 1 diagnostic output 1/2 0 NO (Standard) 1 NC 128 Switchpoint mode BDC4 3) 1 Standard value: Hysteresis value R/W FR DS 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2) Time = 2.5 ms * Value 3) Value = 128: vendor specific. Five measurements are recorded; if the limit is exceeded 3 times, an event is created as a warning Tab. 9 Smart Sensor Profile Parameter - (Smart Sensor Profile Parameters) 2 18 Festo OVEM- -LK 1702a English

19 5.5 Device parameters (Device Parameters) Index Subindex 0x000C 0 Device Access Lock 0x01E2 0 Air-saving function 0x011F 0 Pin-2 configuration 0x Pin-2 switchpoint logic Name Bit Value Description Information 1) Controls the blocking function of the device 0 0 (Write) access to parameters unblocked 1 (Write) access to parameters blocked 1 0 Data storage (DS) unblocked 1 Data storage (DS) blocked 2 0 Local parameterisation unblocked 1 Local parameterisation blocked 3 0 Local user interface unblocked 1 Local user interface blocked 0 Air-saving function is deactivated. Switching status of BDC2 (Out A) is output in Process data IN. 1 Air saving function is activated (standard). Switching status of BDC1 (Out A Air-save) is output to Process data IN. 1 Switching status of BDC3 is output to pin 2 (standard) 5 Switching status of the diagnostic message channel 1 (di1) is output to pin 2. 6 Switching status of the diagnostic message channel 2 (di2) is output to pin 2. 0 Switchpoint logic of pin 2 - NO (standard) 1 Switchpoint logic of pin 2 - NC 0x01EA 0 Lock Code 0 Local parameterisation is enabled (standard) 1 0x Auto-Drop time (40 ms 10 s) Local parameterisation is blocked through security code (max. 9999) Length of the automatic ejector pulse 2) Standard: 80 (200 ms) R/W FR DS 1) R/W = read and write, FR = restore factory settings (Factory Reset), DS = data storage (Data Storage) possible 2) Length of the automatic ejector pulse = 2.5 ms * Value Tab. 10 Device parameters (Device Parameters) Festo OVEM- -LK 1702a English 19

20 5.6 Observation parameters (Observation Parameters) Index Subindex Name Value Description Information 1) Process data (Process data) 0x Process data input Includes the last valid process input data; standard: 0 1 Process data input BDC3 status 0 BDC3 inactive 1 BDC3 active 2 Process data input BDC1/BDC2 status 2) 0 BDC1 or BDC2 inactive 1 BDC1 or BDC2 active 3 Process data input Pressure value (0 1 bar) Last valid pressure value 0x Process data output 0 3 Includes the last valid process output data; standard: 0 2 Process data output BCS1 3 Process data output BCS2 Run-time parameters (Run Time Parameters) 0x Minimum process value 0x Maximum process value 0 Vacuum solenoid valve not switched 1 Vacuum solenoid valve switched 0 Ejector pulse solenoid valve not switched 1 Ejector pulse solenoid valve switched (0 mbar 1 bar) (0 mbar 1 bar) 0x Last process value (0 mbar 1 bar) 0x Minimum evacuation time 0x Maximum evacuation time (0 10 s) (0 10 s) 0x Last evacuation time (0 10 s) 0x Minimum ventilation time (0 10 s) Minimum measured pressure value as process value Maximum measured pressure value as process value Last measured pressure value as process value Minimum measured evacuation time t 3) E Maximum measured evacuation time t 3) E Last measured evacuation time t 3) E Minimum measured air supply time t 3) B R DR R DR 1) R = read, DR = device restart (Device Reset) 2) With activated air-saving function (Air-saving function = ON), the status of the BDC1 is output With deactivated air-saving function (Air-saving function = OFF), the status of the BDC2 is output 3) Time = 2.5 ms * Value 20 Festo OVEM- -LK 1702a English

21 0x Maximum ventilation time (0 10 s) 0x Last ventilation time (0 10 s) Description Maximum measured air supply time t 3) B Last measured air supply time t 3) B Information 1) R DR 1) R = read, DR = device restart (Device Reset) 2) With activated air-saving function (Air-saving function = ON), the status of the BDC1 is output With deactivated air-saving function (Air-saving function = OFF), the status of the BDC2 is output 3) Time = 2.5 ms * Value Tab. 11 Observation parameters (Observation Parameters) 5.7 Diagnostics (Diagnosis) General diagnostic parameters Index Index Subindex Name Value Run-time parameters (Run Time Parameters) Subindex Name Value Description Information 1) 0x Error count 0 Number of errors (device status 3) since the device was switched on or reset 0x Device status 0 Device is working correctly (standard) 1 Maintenance required 2 Device outside specification 3 4 Function test or failure 0x Detailed device 0 Detailed device status Tab. 13 status 0x Supply voltage 7864 (24 V) Current power supply to the device as process value R DR 1) R = read, DR = device restart (Device Reset) 2) Voltage value = 50 V * value/16283 Tab. 12 General diagnostic parameters (Diagnosis) Festo OVEM- -LK 1702a English 21

22 Detailed device status (Detailed Device Status, Event Codes) Name Event Code Description Subindex Information 1) 1 Device failure 0x5000 Hardware errors in the device R 2 Supply fault 0x5100 General errors in power supply DR F 3 Temperature over-run 0x4210 Device temperature exceeded R DR W 4 Pin-4 overload 0x1815 Overload at plug, pin 4 5 Pin-2 overload 0x1816 Overload at plug pin 2 6 Evacuation solenoid failure 7 Ventilation solenoid failure 8 Evacuation time over-run 9 Evacuation time explicit over-run 10 Ventilation time over-run 11 Ventilation time explicit over-run 12 Air-save max. frequency 13 Vacuum low level 14 Supply voltage over-run 15 Supply voltage under-run 0x1820 0x1821 0x1822 0x1823 0x1824 0x1825 0x1826 0x1827 0x5110 0x5111 Vacuum solenoid valve defective Solenoid valve, ejector pulse defective Evacuation time t E exceeded 3 times out of 5 measurements Evacuation time t E exceeded 3 times out of 5 measurements by at least twice the value Evacuation time t B exceeded 3 times out of 5 measurements Evacuation time t B exceeded 3 times out of 5 measurements by at least twice the value Max. switching frequency of the air-saving function exceeded, air-saving function deactivated SP1 at BDC1/BDC2 not reached after 10 s RSP1 fallen below at BDC1/BDC2 SP2 at BDC2 exceeded Supply voltage too high Supply voltage too low 16 Air-save failure 0x182A BDC1 outside the min. limit value, air-save function deactivated 1) R = read, DR = device restart (Device Reset) F = event type fault, W = event type warning Tab. 13 Index 0x0025: detailed device status (Detailed Device Status, Event Codes) 22 Festo OVEM- -LK 1702a English

23 5.8 Device commands (Device Commands) System commands (System Commands) Index Subindex Name Description Information 0x System Command System command, is sent with a command code Tab. 15 W 1) W = write Tab. 14 System commands (System Commands) Command Name Description code (hex) 0x00 Reserved 0x01 ParamUploadStart Start of the parameter upload 0x02 ParamUploadEnd Stopping of the parameter upload 0x03 ParamDownloadStart Start of the parameter download 0x04 ParamDownloadEnd Stopping of the parameter download 0x05 ParamDownloadStore Complete parameterisation and start data storage 0x06 ParamBreak Termination of all Param commands 0x41 SP1 Single Value Teach Determines the teachpoint TP1 for the switching point SP1 for the respective BDCx in the window comparator 0x42 SP2 Single Value Teach Determines the teachpoint TP1 for the switching point SP2 for the respective BDCx in the window comparator 0x43 SP1 Two Value Teach TP1 Determines the teachpoint TP1 for the switching point SP1 for the respective BDCx in the threshold comparator 0x44 SP1 Two Value Teach TP2 Determines the teachpoint TP2 for the switching point SP1 for the respective BDCx in the threshold comparator 0x4B BDCx Teach Start Starting of the Teach-In sequency for the respective BDCx 0x4C BDCx Teach Stop Stopping the Teach-In sequence for the respective BDCx 0x4F Teach Cancel Termination of a Teach-In smaller sequences 0x80 Device Reset Warm start of the device, resetting of the run-time parameters 0x82 Restore factory settings Resetting the configuration and the parameter to the original condition (default values) Tab. 15 Command code (Command Code) Festo OVEM- -LK 1702a English 23

24 6 Installation 6.1 Mechanical Note An unfavourable mounting position can impair the function of the product. Install the vacuum generator so that no condensation from the compressed air lines can gather in the device. Install the vacuum generator so that it cannot be heated above the maximum permissible operating temperature (plan for convection possibilities). Install the vacuum generator so that the exhaust can flow without hindrance. Direct mounting M5 / M4 Tab. 16 Max. 2.5 Nm M3 Max. 0.8 Nm Fig. 6 Direct mounting on the side Fig. 7 Direct mounting on the back OVEM OVEM / -07/ -10 OVEM / -20 Mounting screws M5 M4 Tab. 16 Size of the mounting screws with direct mounting on the side 24 Festo OVEM- -LK 1702a English

25 Mounting on H-rail H-rail mounting accessory M3 Max. 0.8 Nm Mount H-rail mounting Hang OVEM with H-rail mounting in the H-rail and press in the direction of the arrow Secure with screw 1 to the H-rail. Fig. 8 H-rail mounting Mounting via mounting bracket Accessories for mounting bracket M5 / M4 Tab. 16 Max. 2.5 Nm Fig. 9 Mounting with mounting bracket Mounting on supply manifold Mounting is possible on a supply manifold with a maximum of 8 places (Assembly instructions OABM-P Festo OVEM- -LK 1702a English 25

26 6.2 Pneumatic OVEM-...-CE Circuit symbol OVEM-...-OE Circuit symbol OVEM-...-QO-CE OVEM-...-GO-CE OVEM-...-QO-OE OVEM-...-GO-OE OVEM-...-QS-CE OVEM-...-GN-CE OVEM-...-QS-OE OVEM-...-GN-OE Tab. 17 Circuit symbols, pneumatic OVEM GN GO GN GO GN GO GN GO GN GO Tubing length [m] < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 < 0.5 < 2 Min. internal diameter of tubing Supply port [mm] Vacuum port [mm] Exhaust port [mm] Tab. 18 Minimum inside diameter of the connection tubes for connections with G-female thread Notes on the pneumatic connection Maximum permissible tube length 2 m. OVEM-...-GN/GO: Pay attention to the minimum inside diameter of the connection tubes Tab. 18. Do not seal exhaust port. OVEM /-10/-14/-20: If necessary, lengthen silencers with a silencer extension (accessories Recommendation: Use tubes of type PUN from Festo 26 Festo OVEM- -LK 1702a English

27 6.3 Electrical Warning Electric voltage. Risk of injuries caused by electric shock, damage to the machine and system. For the electrical power supply, use only PELV circuits in accordance with IEC /EN Use only voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC /EN Observe the requirements of IEC /EN for PELV circuits. Connect vacuum generator to the IO-Link master. 5-pin plug, M12x1, Porttyp A Maximum tightening torque plug connector M12: 0.5 Nm Maximum permissible cable length: 20 m Plug connector Pin Wire colour 1) Function M12x1 1 1 Brown (BN) L V 2 White (WH) DO2 Digital output Out B (PNP) Blue (BU) L- 0 V 4 Black (BK) C/Q IO-Link communication or 3 5 digital output Out A (PNP) 2) 5 Grey (GY) DI1 Not assigned or digital input (PNP) 3) 1) When using the connecting cable in accessories 2) After a fallback or in the SIO-mode, this pin has the configuration of a digital switching output 3) This pin is not assigned in the IO-Link mode. After a fallback or in the SIO-mode, this pin has the configuration of a digital input Tab. 19 Festo OVEM- -LK 1702a English 27

28 7 Commissioning Note Commissioning should only be conducted by qualified personnel. 7.1 Commissioning vacuum generator At initial commissioning, the vacuum generator is placed in operation with the factory settings Tab. 20. Requirement Vacuum generator is fully mounted and connected Chapter 6. Check operating conditions Check the operating conditions and limit values Technical data. Place vacuum generator OVEM-...-OE in operation 1. Apply operating pressure to compressed air supply port (1). Underpressure is generated at the vacuum connection (2). 2. Switch on the operating voltage. The current pressure value is displayed. The vacuum generator is ready for operation. Place vacuum generator OVEM-...-CE in operation 1. Apply operating pressure to compressed air supply port (1). 2. Switch on the operating voltage. 3. In the IO-Link mode: Activate suction (or in the SIO mode: Apply input signal to pin 5). Underpressure is generated at the vacuum connection (2). The current pressure value is displayed. The vacuum generator is ready for operation. Changing of the operating pressure changes the strength of the underpressure at the vacuum connection. As a result, the vacuum can be set at the suction gripper. Functions and parameters can be determined: in IO-Link operation Chapter 5 manually on the device Chapter through Teach-In Chapter Festo OVEM- -LK 1702a English

29 7.2 Adjusting intensity of the ejection pulse Fig. 10 Screw in flow control screw Requirement Vacuum generator is in operation. Adjust ejector pulse 1. Completely screw in flow control screw for adjusting the ejector pulse. 2. Switch on vacuum generation. The maximum possible underpressure is generated at the vacuum connection (2). 3. Switch off vacuum generation. 4. Switch on solenoid valve ejector pulse. No ejector pulse is generated. 5. Switch off solenoid valve ejector pulse. 6. Unscrew the flow control screw for adjusting the ejector pulse somewhat. 7. Switch on solenoid valve ejector pulse. An ejector pulse is generated. 8. Repeat work steps 1. to 7. until the necessary intensity of the ejector pulse is set. Note When large suction grippers are used, a vacuum independent of the device can be built up for physical reasons. This might mean that the workpiece does not detach from the suction gripper, even if the ejector pulse is set to a sufficiently long duration. Festo OVEM- -LK 1702a English 29

30 8 Operation Communication takes place in the IO-Link mode. SIO mode is supported. Parameter description IO-Link mode Chapter 5 Meaning of the displays Chapter 13.1 Menu structure in the SIO mode Chapter Operating manual override Both solenoid valves can be manually switched with the manual override. Mechanical manual override 1. Press in the stem of the manual override with a blunt pin. The solenoid valve switches. 2. Remove the pin. The stem of the manual override automatically returns. The solenoid valve reverts to the basic position. Fig. 11 Electrical manual override The electrical manual override is actuated with the operating keys (Sub-menu FORC Fig. 15). 8.2 Restore factory settings Through resetting of the factory settings, the parameters, configuration and security code are reset to the condition at shipment Tab. 20. The current settings are lost. The parameters and configurations that can be restored are marked in the parameter description with FR (Factory Reset) Chapter 5. Reset through IO-Link command Execute system command Restore factory settings Tab. 15. Resetting with operating buttons on the device 1. Switch off the operating voltage. 2. Simultaneously press and hold down A-key + B-key + Edit button. 3. Switch on the operating voltage. 4. Release the A-key + B-key + Edit button. LCD display shows [CLEA]. The factory settings are restored. 30 Festo OVEM- -LK 1702a English

31 Factory settings Parameter OVEM-...-H OVEM-...-L Switching mode of the electrical output Threshold value comparator Switching logic of the electrical output NO (Normally Open) Air-saving function Active Security code OFF BDC1 - Out A (Air-save) SP1-0.7 bar -0.4 bar Hysteresis 0.25 bar BDC2 - Out A SP1-0.7 bar -0.4 bar SP bar bar Hysteresis 0.25 bar 0.1 bar BDC3 - Out B SP1-0.5 bar -0.2 bar SP bar bar Hysteresis 0.2 bar 0.1 bar Duration of ejector pulse 200 ms Tab. 20 Factory settings 8.3 Activating security code A security code can be established and activated to prevent changes to parameter settings and configurations from being made locally by unauthorised persons. The security code protects against entries made locally through the operating keys on the device. IO-Link parameterisation is not affected. Factory setting OFF. The security code is reset when factory settings are restored. For entry and activation in the Edit mode Chapter Festo OVEM- -LK 1702a English 31

32 9 Error messages and fault clearance The diagnostic messages are shown as event code in the IO-Link mode and as error code in the display. In addition, diagnostic messages can also be signaled through the switching output Out B. In the IO-Link mode, a variety of diagnostic and monitoring functions are available. 9.1 Status messages Status Type Definition 0 Device is OK 1 Notification Check required 2 Warning Outside the specification 3 Error Malfunction Tab. 21 Status messages diagnostics IO-Link 9.2 Diagnostic levels There are 4 diagnostic levels. The red background illumination of the display lights up for messages of the diagnostic levels 1 to 3. As an additional diagnostic option, the vacuum generator has a diagnostic message channel. This can be set with the configuration of pin 2 Chapter Configuration options for pin 2: definition as switching output (In A1) diagnostic message channel 1 (di1) diagnostic message channel 2 (di2) The diagnostic message channel can be configured as normally open (NO) or normally closed (NC). Diagnostic level Diagnostic message channel Description 0 No message Device is OK. 1 Logical channel di1 active 2 Logical channel di1 or di2 is active 3 Logical channel di1 or di2 is active No restriction in function yet, but operating parameters are worsening Function still ensured, but with restrictions (e.g. higher power consumption). Emergency operation, maintenance urgently required. Function is no longer assured. All controllable outputs of the device are inactive. Tab. 22 Diagnostic levels for switching output Out B and display 32 Festo OVEM- -LK 1702a English

33 9.3 Error messages and error codes Display Eventcode IO-Link D 1) S 2) Description Remedy Er1 0x Hardware errors in the device Replace device Er17 0x Supply voltage is too high or too Check power supply low (error) Er20 0x Permissible device temperature exceeded Keep device away from heat sources Er21 0x Short-circuit Out A Check output for overload Er22 0x Short-circuit Out B Er32 0x Vacuum solenoid valve does not switch or does not switch correctly Er33 0x Ejector pulse solenoid valve does not switch or does not switch correctly Er34 0x Evacuation time exceeded in 3 of 5 cycles (warning) Er35 0x Evacuation time exceeded by a factor of two in 3 of 5 cycles Er36 0x Air supply time exceeded in 3 of 5 cycles (warning) Er37 0x Air supply time exceeded by a factor of two in 3 of 5 cycles Er38 0x Switching frequency of the air saving function > 1 Hz (warning) [Option] flashing 0x182A 0 2 Air-save function deactivated because outside the limit value Er39 0x SP1 for Out A not reached after 10 s Er40 0x Supply voltage too high (warning) Er41 0x Supply voltage too low (warning) 1) Diagnostic levels display 2) Status IO-Link Tab. 23 Error messages, error codes, diagnostic levels and error description Check installation Press mechanical manual override several times Check power supply Replace device Check for leakage Check parameterisation SP1 of BDC4 Check for leakage Lengthen air supply time Check throttle setting Check parameterisation SP2 of BDC4 Check for leakage Check parameterisation BDC1 Check for leakage Check parameterisation BDC1 Check for leakage Check parameterisation BDC1 / BDC2 Check power supply Festo OVEM- -LK 1702a English 33

34 9.4 Malfunctions Malfunction Possible cause Remedy Workpiece does not detach from the suction gripper Switching output does not react in accordance with the settings Device-independent vacuum between workpiece and suction gripper, ejector pulse not activated or sufficiently dimensioned Activate ejector pulse when lifting the suction gripper Increase the duration and intensity of the ejector pulse Tubing dimensioned incorrectly Replace tubing (tubing dimensions Chapter 6.2) Flow control screw closed Open the flow control screw Short circuit or overload at the Eliminate short circuit or overload output Device defective Replace device No display Operating voltage faulty Apply permissible operating voltage Chapter 6.3 Electrical connections swapped Connect device correctly Chapter 6.3 Device defective Replace device Incomplete display Display defective Replace device Pressure indicator incorrect Pneumatic connections swapped Connect device correctly Chapter 6.2 Settings cannot be edited, [Lock] is displayed [min] + [max] flash simultaneously Display + [min] + [max] flash simultaneously Display flashes and error code appears Security code activated Enter security code Chapter 8.3 Diagnostic level 1 active Chapter 9.2 Diagnostic level 2 active Chapter 9.2 Diagnostic level 3 active Chapter 9.2 [Option] flashing Teach-In Faulty Set hysteresis larger, Teach-In repeat Tab Festo OVEM- -LK 1702a English

35 10 Disassembly 1. Switch off energy sources. operating voltage compressed air 2. Disconnect pneumatic and electrical connections from the device. 3. Loosen mountings and remove device. 11 Maintenance and care Clean device 1. Switch off energy sources. operating voltage compressed air 2. Clean device with non-abrasive cleaning agents. 3. Check air filter through the inspection window for dirt. Replace air filter 2 1 Fig. 12 Remove / install air filter 1. Vent the vacuum generator. 2. Carefully pull out the slide 1 up to the first detent. The slide must stay in this position on the filter. 3. Pull out filter 2. Clean, if necessary. 4. Push filter into the housing. 5. Push in slide. The filter is pushed by the slide into the vacuum generator. Festo OVEM- -LK 1702a English 35

36 12 Technical data OVEM / / -20 General Approval RCM CE mark In accordance with EU EMC Directive ( declaration of conformity) Characteristic values Operating pressure OVEM-...-QS / -GN / -PL [bar] 2 6 Operating pressure OVEM-...-QO / -GO / -PO [bar] 2 8 Pressure measuring range [bar] -1 0 Overload pressure at vacuum port [bar] 5 Ready-state delay [ms] 500 Dead time (evacuation and ejection) [ms] Electronics Nominal operating voltage [V DC] 24 ± 15 % Max. output current (for all switching outputs) [ma] 100 Voltage drop (for all switching outputs) [V] 1.8 Idle current [ma] 70 Coil characteristics, 24 V DC - low current phase [W] 0.3 Coil characteristics, 24 V DC - high current phase [W] 2.55 Time until current reduction [ms] 80 Capacitive load maximum DC [nf] 100 Overload protection Provided Inductive protective circuit Adapted to MZ, MY, ME coils Insulation voltage [V] 50 Surge resistance [kv] 0.8 Max. current consumption In IO-Link mode [ma] 150 In SIO-mode without master connection [ma] 270 Accuracy [% FS] ± 3 Hysteresis [% FS] ± 0.1 Short-circuit resistance Provided Protection against incorrect polarity For all electrical connections Display/operation Threshold value setting range [bar] Hysteresis setting range [bar] Environment Ambient temperature [ C] 0 50 Temperature of medium [ C] 0 50 Operating medium Compressed air in accordance with ISO :2010 [7:4:4] Note on the operating medium Lubricated operation not possible 36 Festo OVEM- -LK 1702a English

37 OVEM / / -20 Note on materials Resistance to shock (in accordance with IEC /EN60068) Vibration resistance (in accordance with EN ) Protection class RoHS-compliant 30 g acceleration with 11 s duration (half-sine) Hz: 0.35 mm / Hz: 5 g III Degree of protection IP 65 Relative air humidity [%] 5 85 Interference emission In accordance with EN Interference immunity In accordance with EN Materials Information on materials - seals NBR Information on materials - housing Die-cast aluminium, PA reinforced Information on materials - plug housing housing Nickel-plated brass Tab. 25 Festo OVEM- -LK 1702a English 37

38 13 Appendix 13.1 Graphic display and LCD displays C 4 aj Status BDC1 (Out A Air-save) / BDC2 (Out A) 2 Status BDC3 (Out B) / diagnostics level Status IO-Link communication 4 4-digit alphanumeric display 5 Toolbar for functions Tab Segment bar to the right: graphic display of the current status of the digital inputs or valve status Tab B-key 8 A-key 9 EDIT button aj Segment bar to the left: Graphic display of the current pressure value related to the maximum measured value of the measuring range Fig. 13 LCD display and operating keys 38 Festo OVEM- -LK 1702a English

39 Symbol C [SP] [SP] + [min] [SP] + [max] [HY] [NO] / [NC] [TeachIn] [Option] [Lock] <IOL> + [Lock] L1 L3 Tab. 26 L2 L10 L12 L16 L18 Description C flashes: IO-Link mode active Threshold value comparator selected Switchpoint Window comparator selected Lower switchpoint Upper switchpoint Hysteresis Switching logic normally open (Normally open) / normally closed (Normally closed) Teach-In mode active Air-saving function active Security code active Device Access Lock active The device can only be configured and parameterised in IO-Link operation. Segments of the graphic display of the current status of the digital inputs or valve status. Segment L10: status of the vacuum solenoid valve. Valve is switched when the segment is illuminated. Segment L12: status of the ejection pulse solenoid valve. Valve is switched when the segment is illuminated. Segment L16: status of the digital switching input DI1 (suction). Switching input set when segment is illuminated. Segment L18: status of the digital switching input DI2 (ejection). Switching input set when segment is illuminated. Symbolism in display Festo OVEM- -LK 1702a English 39

40 Display Segment L17 + [A] illuminated and [min] flashing Segment L17 + [A] illuminated and [max] blinkt Segment L18 + [B] illuminated and [msec] + [_ _] flashing Description Display of minimum pressure value Display of maximum pressure value Duration of ejector pulse Segments L1, L3, L4, L5 illuminated and [msec] + [_ ] + [min] flashing [msec] + [_ ] + [max] flashing [msec] + [ _] + [max] flashing [msec] + [ _] + [max] flashing [msec] + [_ ] + [SP] + [max] flashing [msec] + [ _] + [SP] + [max] flashing Segments L1, L2, L5, L6 illuminated and display <ON> + [Option] flashing Segments L1, L2, L5, L6 illuminated and [Lock] flashing Segment L10 illuminated and symbol B illuminated + display <FORC> Diagnostics of evacuation and air supply times Display of minimum evacuation time Display of maximum evacuation time Display of minimum air supply time Display of maximum air supply time Setting of evacuation time limit value Setting air supply time limit Setting of air-saving function (EDIT mode) <ON>: Air-saving function active <OFF>: Air-saving function not active Setting security code (1 9999) <OFF>: Security code not active Additional functions of the electrical manual override via operating buttons Vacuum solenoid valve switched Segment L12 illuminated and symbol B illuminated + display <FORC> Additional functions of the electrical manual override via operating buttons Ejector pulse solenoid valve (Eject) switched Tab. 27 Examples for additional displays of segment bars 40 Festo OVEM- -LK 1702a English

41 13.2 Operating statuses and menu structure Meaning of symbols for representing the menu structure Symbol Meaning Automatic return to the RUN mode when the monitoring time has expired (here 80 seconds) Press EDIT button for 3 seconds: manual return to the RUN mode Symbol on the display flashes (here display segment switching output Out A) / Input blocked / not blocked (safety code active / not active) Press individual key (here A-key) Press A-key or B-key, set value Press keys simultaneously (here: B-key and Edit button) Press the Edit button Branch Error display Reset values Cycle Vacuum solenoid valve switched Ejector pulse solenoid valve switched Teach point is taken over Special menu (SPEC) is active (setting of the air saving function, security code, max. evacuation and max. air supply time) Tab. 28 Meaning of symbols for representing the menu structure RUN mode Basic status after the operating voltage is switched on Display of the current measured value (relative pressure) Display of the signal statuses of the solenoid valves Display of the selected inputs and outputs Festo OVEM- -LK 1702a English 41

Vacuum generator OVEM. Operating instructions f [ ]

Vacuum generator OVEM. Operating instructions f [ ] Vacuum generator OVEM en Operating instructions 8079719 2017-10f [8079721] Original instructions OVEM-DE Identification of hazards and instructions on how to prevent them: Warning Hazards that can cause

More information

Vacuum generators OVEM

Vacuum generators OVEM Key features At a glance Rapid purging of vacuum for safe placement of the workpiece by means of an integrated solenoid valve for controlling the ejector pulse Central electrical connection via an M12

More information

Valve terminal VTUG-...-M/VTUG-...-V

Valve terminal VTUG-...-M/VTUG-...-V Valve terminal VTUG-...-M/VTUG-...-V 2 Design 2. Standard valve terminal (straight connecting plate) 2 3 4 Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 7 347-0 www.festo.com Brief description

More information

Vacuum generators OVEM

Vacuum generators OVEM Key features At a glance Accelerated vacuum reduction for safe placement of the workpiece by means of integrated solenoid valve for controlling the ejector pulse Central electrical connection via M12 plug

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

Vacuum generators OVEM

Vacuum generators OVEM Key features At a glance Rapid purging of vacuum for safe placement of the workpiece by means of an integrated solenoid valve for controlling the ejector pulse Central electrical connection via an M12

More information

Vacuum generators Key features

Vacuum generators Key features Vacuum generators Vacuum generators Key features Product overview Vacuum generator All Festo vacuum generators have a single-stage design and operate according to the venturi principle. The product families

More information

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features sales@jumo.co.uk info.us@jumo.net Page 1/10 JUMO dtrns p5 Pressure Sensor with IO-Link pplication Process automation Machines for the food and beverage industry General mechanical and apparatus engineering

More information

Solenoid valves MH2/MH3/MH4, fast-switching valves

Solenoid valves MH2/MH3/MH4, fast-switching valves Solenoid valves MH2/MH3/MH4, fast-switching valves Fast-switching valves from Festo: it's not just the switching that's fast The fast-switching professionals with response times down to 2 milliseconds

More information

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces: Electronic pressure switch Type HEDE 10 RE 30277 Edition: 2017-02 Replaces: 2016-06 Component series 3X Maximum operating pressure 600 bar Features Suitable for measuring pressures in hydraulic systems

More information

Solenoid valves VMPA

Solenoid valves VMPA Key features Innovative Versatile Reliable Easy to mount Slim high-performance valves in a sturdy metal housing MPA1 (width 10 mm): flow rate up to 360 l/min MPA14 (width 14 mm): flow rate up to 670 l/min

More information

Proportional pressure regulators VPPX

Proportional pressure regulators VPPX Features LED indicators Plug socket with cable Venting at both ends Manifold block Sub-base valve Angle bracket Individual valve H-rail mounting repositionable by 180 Compressed air supply at both ends

More information

Solenoid valves MH2/MH3/MH4, fast-switching valves

Solenoid valves MH2/MH3/MH4, fast-switching valves Solenoid valves MH2/MH3/MH4, fast-switching valves Fast-switching valves from Festo: it's not just the switching that's fast The fast-switching professionals with response times down to 2 milliseconds

More information

Proportional pressure regulators MPPES

Proportional pressure regulators MPPES Product range overview Function Type Circuit symbol Design Pneumatic connection 1 Proportional pressure regulators With proportional solenoid MPPES Directly actuated valve Nominal size pressurise/ exhaust

More information

Vacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design.

Vacuum generators 1.1. High vacuum levels of up to 93% Easy connection of holders and suction cups. Lightweight and compact design. High vacuum levels of up to 93% Easy connection of holders and suction cups Lightweight and compact design No wearing parts Long service life Vacuum monitoring with vacuum switch 2005/07 Subject to change

More information

Solenoid valves MHJ, fast-switching valves

Solenoid valves MHJ, fast-switching valves Solenoid valves MHJ, fast-switching valves Solenoid valves MHJ, fast-switching valves Key features Innovative Versatile Reliable Easy to install Individual electrical connection via connecting cable and

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Standard cylinders DDPC, with measured-value transducer DADE

Standard cylinders DDPC, with measured-value transducer DADE Features Components for positioning and measuring using the standard cylinder DDPC Measuring with measured-value transducer DADE Positioning with end-position controller SPC11 or controller module CPX-CMAX/-CMPX

More information

Pneumatic components for high-pressure applications

Pneumatic components for high-pressure applications Pneumatic components for high-pressure applications Pneumatic components for high-pressure applications, series L Product range overview Function Version Type Size Pneumatic connection 1, 2 Page Direct

More information

Motion Terminal VTEM. Festo core product range Covers 80% of your automation tasks

Motion Terminal VTEM. Festo core product range Covers 80% of your automation tasks q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qgenerally ready

More information

standards based cylinder DNCI Operating instructions e [ ]

standards based cylinder DNCI Operating instructions e [ ] standards based cylinder DNCI en Operating instructions 8072823 2017-05e [8072825] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

Valve terminals CPV-SC, Smart Cubic

Valve terminals CPV-SC, Smart Cubic Key features Innovative Versatile Reliable Easy to mount Small, compact valve terminal for a wide range of pneumatic applications Enormous flexibility during planning, assembly and operational use Multi-pin

More information

Solenoid valves VUVG/valve terminals VTUG

Solenoid valves VUVG/valve terminals VTUG Solenoid valves VUVG/valve terminals VTUG q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Valve terminal MPA-...

Valve terminal MPA-... Valve terminal MPA-... Description Electronics MPA-... MPA electronic modules Types: - VMPA1-FB- - VMPA2-FB- - VMPA1-FB- D2 - VMPA2-FB- D2 VPPM/MPA proportionalpressure regulator Type: - VPPM- TA- - VPPM-

More information

Pressure sensors SPAU

Pressure sensors SPAU Key features At a glance Product description The pressure sensor SPAU is suitable for monitoring compressed air and noncorrosive gases. The variant with display offers the option of reading the pressure

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Solenoid valves VUVG/valve terminals VTUG

Solenoid valves VUVG/valve terminals VTUG Solenoid valves VUVG/valve terminals VTUG q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Mini slide EGSC-BS-KF. Operating instructions b [ ]

Mini slide EGSC-BS-KF. Operating instructions b [ ] Mini slide EGSC-BS-KF en Operating instructions 8081968 2017-11b [8081970] Translation of the original instructions EGSC-BS-KF-EN Identification of hazards and instructions on how to prevent them: Danger

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

Proximity sensors SMT/SME-10, for C-slot

Proximity sensors SMT/SME-10, for C-slot Proximity sensors SMT/SME-10, for C-slot Proximity sensors SMT/SME Product range overview Design Type of mounting Measuring principle Type Operating voltage range For C-slot Standard Insertable in slot

More information

Standard valves to ISO Product range overview

Standard valves to ISO Product range overview Standard valves to ISO 15218 Product range overview Function Electrical connection Voltage Manual override Page/Internet Pilot valve to ISO 15218 Width 15 mm Plug connector type C, to EN 175301-803 Plug

More information

Positioners CMSX. Festo core product range Covers 80% of your automation tasks

Positioners CMSX. Festo core product range Covers 80% of your automation tasks Positioners CMSX q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Linear gantry EXCT. Description. Mechanical installation NH [ ]

Linear gantry EXCT. Description. Mechanical installation NH [ ] Linear gantry EXCT Description Mechanical installation 8059080 60NH [805908] EXCT Translation of the original instructions EXCT-EN LOCTITE is a registered trademark of its respective trademark holder in

More information

-M- Flow rate 100 l/min. M5 Compact System Key features

-M- Flow rate 100 l/min. M5 Compact System Key features M5 Compact System Key features -M- Flow rate 100 l/min Forms the basis for compact pneumatic control systems M5 elements with 2n sub-bases Control cabinet installation Easy mounting Fast replacement of

More information

COUNTIS E22 Three-phase energy meter Direct - 80 A

COUNTIS E22 Three-phase energy meter Direct - 80 A Instruction manual COUNTIS E22 Three-phase energy meter Direct - 80 A EN www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings... 4 2.1. Risk of electrocution, burns

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Toothed belt axis ELGC-TB-KF. Operating instruction [ ] Toothed belt axis ELGC-TB-KF en Operating instruction 8068220 2017-02 [8068222] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can

More information

Solenoid/pneumatic valves, ISO

Solenoid/pneumatic valves, ISO Solenoid/pneumatic valves, ISO 15407-1 q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instruction for Electronic Pressure Switch. Model: PDD Operating Instruction for Electronic Pressure Switch Model: PDD 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

SPG-DIGI. Operating Instruction. Please read carefully before use!

SPG-DIGI. Operating Instruction. Please read carefully before use! WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com

More information

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor DCT 5 Industrial Pressure Transmitter with IO-Link Interface Stainless Steel Sensor accuracy according to IEC 60770: standart: ± 0.5 % FSO sption: ± 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0...

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display

More information

Electronic pressure switch with two switching outputs

Electronic pressure switch with two switching outputs Electronic pressure switch with two switching outputs RE 30278/04.14 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /2/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code 2

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

Solenoid valves VUVB/valve terminals VTUB, NPT

Solenoid valves VUVB/valve terminals VTUB, NPT Solenoid valves VUVB/valve terminals VTUB, NPT Solenoid valves VUVB/valve terminals VTUB, NPT Key features Innovative Versatile Reliable Easy to mount Valve terminal for a wide range of pneumatic applications

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Operating pressure: -4.5-74 psi electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display Units displayed Switching logic Ambient

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI5000 SI / / 2007 Operating instructions Flow monitors SI5000 SI5001 704056 / 01 06 / 2007 Contents 1 Safety instructions... 3 2 Functions and features... 4 2.1 Application area... 4 2.2 Operating principle flow monitoring...

More information

Solenoid valves VUVB/valve terminals VTUB

Solenoid valves VUVB/valve terminals VTUB Solenoid valves VUVB/valve terminals VTUB Solenoid valves VUVB/valve terminals VTUB Key features Innovative Versatile Reliable Easy to mount Valve terminal for a wide range of pneumatic applications Standardised

More information

3.10 Air Conditioning (A/C) Contents

3.10 Air Conditioning (A/C) Contents 3.10 Air Conditioning (A/C) Contents 3.10 Model 208 as of M.Y. 1998 Diagnosis Page Function Test................................... 11/1 Reading Actual Values............................ 12/1 Version Code...................................

More information

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM- Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Spindle axis ELGC-BS-KF. Operating instructions [ ] Spindle axis ELGC-BS-KF en Operating instructions 8067243 2017-01 [8067245] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can lead

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung

More information

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual Flowmeter Ultrasonic Flow Metering / Dosing Device Operating Manual Read the user's manual carefully before starting to use the unit or software. Producer reserves the right to implement changes without

More information

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview Overview Modular multi-functional valve manifold for up to 3 valves: Type 44 VTSA, ISO 15407-/ISO 5599- Type 45 VTSA-F with optimized flow Different valve sizes on one valve manifold: 18 mm (ISO 0) 6 mm

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

Operating instructions Flow monitor SI / / 2014

Operating instructions Flow monitor SI / / 2014 Operating instructions monitor SI5002 80000385 / 00 07 / 2014 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

CPLab / CP Factory. Application module magazine. Data sheets

CPLab / CP Factory. Application module magazine. Data sheets CPLab / CP Factory Application module magazine Data sheets Data sheet: Push-in fitting QSM-M5-4 #153304 Size Mini Nominal size 2.2 mm Type of seal on screw-in stud Sealing ring Container size 10 Design

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW) Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW) (en) Operating instructions 8068554 2017-05c [8068556] Original instructions Symbols: Warning, Caution Fitting and commissioning to be carried out

More information

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04) INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS 300 6720613720-00.1 SD UK/IE CONTENTS Contents Contents 2 1 Safety instructions and explanation of symbols 5 1.1 General safety instructions

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011 Operating instructions Flow monitors SI6600 SI6700 SI6800 UK 704680/02 01/2011 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Functions and features 4 3.1 Application

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

zelsius Installation and operating manual All that counts. EnergyMetering

zelsius Installation and operating manual All that counts. EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter with single jet flow sensor M-Bus and 2 inputs/outputs optional qp 0.6/1.5/2.5 m³/h All that counts. General information

More information

Operating instructions Binary level sensor. LI214x /00 04/2016

Operating instructions Binary level sensor. LI214x /00 04/2016 Operating instructions Binary level sensor LI214x 704776/00 04/2016 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Electronic pressure switch with integrated analogue output

Electronic pressure switch with integrated analogue output Electronic pressure switch with integrated analogue output RE 30276/03.1 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /1/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code

More information

Planar surface gantry EXCM-30. Instructions. Mechanical installation b [ ]

Planar surface gantry EXCM-30. Instructions. Mechanical installation b [ ] Planar surface gantry EXCM-30 Instructions Mechanical installation 804447 605b [8044434] EXCM-30 Translation of the original instructions LOCTITE is a registered trademark of its respective trademark holder

More information

Quarter turn actuator DAPS..R..-F..

Quarter turn actuator DAPS..R..-F.. Quarter turn actuator DAPS..R..-F.. Festo AG & Co. KG Postfach D-73726 Esslingen +49 711 347-0 www.festo.com (en) Operating instructions 8030408 1309g [8030416] Original: de Quarter turn actuator DAPS..R..-F.....

More information

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions Your Global Automation Partner LTX Linear Position Sensors with SSI Interface Operating instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). PD 65493 GB1 20001-01 ThinkTop DeviceNetTM 11-25 VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). Application The ThinkTop is designed to ensure optimum valve control

More information

Valve terminals MPA-F

Valve terminals MPA-F Key features Innovative Versatile Reliable Easy to mount Manifold blocks, tubing connections and exhausts designed for optimum flow rates Tubing diameters: Working ports up to 10 mm Supply ports up to

More information

Stepper motors EMMS-ST

Stepper motors EMMS-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qgenerally ready

More information

Proportional directional control valves MPYE

Proportional directional control valves MPYE Key features General information The directly actuated proportional directional control valve has a position-controlled spool. This transforms an analogue input signal into a corresponding opening cross-section

More information

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011 Operating instructions Flow monitors SI6000 SI6100 SI6200 706053/00 06/2011 Contents 1 Safety instructions... 3 2 Functions and features... 4 2.1 Application area... 4 2.2 Operating principle flow monitoring...

More information

ThunderION. Static Neutralising System. GB User's Manual 2

ThunderION. Static Neutralising System. GB User's Manual 2 ThunderION SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon +31-(0)573-288333 Telefax +31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

ELGC-BS-KF. Spindle axis. Instructions Operating c [ ]

ELGC-BS-KF. Spindle axis. Instructions Operating c [ ] ELGC-BS-KF Spindle axis Instructions Operating 8095590 8095590 2018-08c [8095592] Translation of the original instructions 2 Festo ELGC-BS-KF 2018-08c Table of contents 1 Further applicable documents...

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electrically Released Brakes ERS VAR11-01 FT = 4100 N SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC

More information

Linear actuators DFPI

Linear actuators DFPI Linear actuators DFPI Linear actuators DFPI Key features General information Linear actuator for actuating process valves such as gate valves and shut-off valves in process automation systems Linear actuator

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information