1 Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature range 1 to 150 C Temperature diff 3 to 120K Supply 3.6V Lithium battery Battery life 6 years (optional 11 year available upon request) Display Multifunction 8-digit + characters LCD Output pulse 30Vdc 20mA Frequency: 1Hz Pulse duration 400m/s <T P <600m/s M-Bus Baud rate 2400 Sensor type PT500 Matched pair Pocket thread ½ BSP Ambient range: Temperature 5 to 55 C RH 95% non-condensing Dimension 106 x 54 x 120mm (H x L x W) Output pulse 30Vdc, 20mA max Pulse width ms Conformity: EN1434, MID M1/E1 Class 3 Protection IP54 MW-DM Integrator (build unit with following options) Output type (add to above code) -P Pulsed output -M M-Bus output Pockets & PT500 sensors (add to above code) -A 45mm Pockets, sensors 1.5 m cable -B 105mm Pockets, sensors 3 m cable -C 105mm Pockets, sensors 10 m cable -D 140mm Pockets, sensors 3 m cable -E 140mm Pockets, sensors 10 m cable System type (add to above code) -4 Heating system -5 Cooling system -6 Heat/cooling system Replacement items MW-PKT-1 45mm Stainless steel pockets (pair) MW-PKT-2 105mm Stainless steel pockets (pair) MW-PKT-3 140mm Stainless steel pockets (pair) Page 1 of 7

2 Technical Overview The MW-MD range of Heat Meter Integrators uses the latest innovative technology to calculate heat usage from heating and cooling systems. They are for use with mechanical flow parts. With its dynamic measuring cycle even the smallest energy consumptions are reliably collected. The large multifunction display permanently shows the heat consumption total, and by using the button is it possible to scroll through the display to show all data. General Information Initial verification The MW-MD is produced and tested in compliance with the new European measuring instruments directive (MID). According to this directive, devices do no longer carry an initial verification stamp, but rather the year of the device s declaration of conformity (recognizable on the front of the device, for example: M09). The MID controls the use of heat meters up to the moment they are placed on the market resp. their first putting into use. After this, the national regulations for devices subject to legal verification apply within the EU. The duration of initial verification validity in Germany remains 5 years for heat meters. After this period has expired, the measuring device may no longer be used for billing in commercial use. The regulations resp. validity period may vary in other countries of the EU. Electro-magnetic interference The MW-MD fulfils the national and international requirements for interference resistance. To avoid malfunctions due to other interferences, do not install fluorescent lamps, switch cabinets or electric devices such as motors or pumps in the immediate vicinity of the meter (minimum distance 1 m). Cables leaving the meter should not be laid parallel to live cables (230V, minimum distance 0.2 m). Care instructions Clean plastic surfaces with a damp cloth only. Do not use any scouring or aggressive cleaning agents! The device is maintenance-free during the service life. Repairs can only be made by the manufacturer. General Information (continued) Declaration of Conformity Sontay Ltd declares that this product with the number of the EC type examination certificate DE-08-MI004-PTB012 complies with the requirements of the EC directives 2004/22/EC (Measuring instruments directive) and 89/336/ EEC (electro-magnetic compatibility). Status / Error Codes The symbols in the table below show the meter s operational status. The status messages only appear in the main display (energy)! The temporary display of the warning triangle can be caused by special operating states and does not always mean that the device is malfunctioning. However, should the symbol be displayed over a longer period of time you should contact Sontay. Symbol Status Event Flow existent - Attention Check for errors Data transmission - Emergency operation Exchange device External power supply - Error codes show faults detected by MW-MD. If more than one error appears, the sum of the error codes is displayed: Error 1005 = error 1000 and error 5. Code Error Event 1 Short-circuit return sensor Check sensors 2 Interruption return sensor 3 Short circuit supply sensor 4 Interruption supply sensor 5 Hardware error Exchange device 6 Battery empty/wrong temp sensor Check 7 Temp. out of measuring range Correction of heating system 100 Emergency operation Exchange device 1000 Battery life time exceeded 2000 Initial verification expired >8000 Internal hardware error Page 2 of 7

3 Installation Safety instructions The installation has to be done by qualified personnel. Read the instructions carefully right up to the end before starting to mount the device. Installation (continued) Installation heat calculator Sontay recommends to mount the calculator on the wall. Do not mount the device at the pipe or attach it directly on the flow sensor. The current laws and regulations have to be observed, especially EN 1434 part 1+6. At devices with communication interfaces or mains supply the general technical rules and the correspondent regulations have to be followed. The mounting adapter at the backside of the calculator can be used for DIN-rail mounting or reverse for wall mounting. For wall mounting attach the adapter with at least two screws to the wall and clip the calculator on it. While demounting flow sensors and temperature sensors care should be taken to ensure that no heating water escapes from the pipe this can cause burns! For rail mounting lift the adapter a little bit, place the calculator on the rail and push the adapter back until it locks. Close valves and release pressure before installation. Take care of: The display must readable at all times, to avoid malfunctions due to other interferences do not install fluorescent lamps, switch cabinets or electric devices such as motors or pumps in the immediate vicinity of the meter (minimum distance 1 m). All welding must be finished. The ambient temperature must not exceed 55 C. The type of temperature sensor must correspond with the calculator. The pulse value of the flow sensor must correspond with the one from the calculator. The calculator has 7 screwed cable glands for wires with a diameter between 4.2 and 10 mm. Keep unused glands closed. DIN-rail mounting Wall mounting Connection sensors The mounting of the temperature sensors should be done symmetrical with direct immersion. If immersion sleeves are used they have to be checked for conformity to MID and have to be marked accordingly. The installation of immersion sleeves has to be done according to DIN EN The sensor cables are marked with colours (red = supply, blue = return). Do not buckle, extend or shorten the wires! Do only use paired sensors with the same serial number on it. Mind the connection order: temperature sensors first, flow sensor afterwards! Supply and return sensors must be inserted into the immersion sleeves completely. The MW-MD is delivered ready for operation. It does not need any settings or adjustment. Installation points in the flow sensor can be used for symmetrical installation of the temperature sensors. Seal temperature sensor after installation to prevent unauthorized demounting (seals included). Do not wrap or install wires along hot pipes. Page 3 of 7

4 Installation (continued) Connections Connection flow sensor The total length of the wire between flow sensor and calculator should not exceed 10 m. Mind the polarity at electronic flow sensors. Operation test Check the calculator for any error codes in the display after installation (see Page 2 for error codes). Most of the errors can be deleted by pressing the button. If the error appears permanently, it will be detected at the next measuring cycle and displayed again. Check whether the volume information is updated and the displayed temperatures correspond to the present ones while the system is running (measuring cycle 2 minutes max.). When attaching the top cover on the housing pulses on the inputs can possibly be generated. Check readings of the inputs and correct if necessary. Sealing Seal the device with the included seals to prevent unauthorized opening. Maintenance Repairs or overhaul are only allowed by the manufacturer or companies authorized by the manufacturer. Temperature sensors Supply (hottest pipe) 1 2 Return (coolest pipe) 3-4 Flow sensor pulse 10 GND 11 If water meters with a potential free reed contact are connected to the inputs the connection can be made in any direction. Energy output pulse 52 GND 53 Volume output pulse 54 GND 55 Care must be taken when connection is made to a BMS. M-Bus L1 24 L2 25 M-Bus connections are given twice for incoming and outgoing of the M-Bus wires. Outputs Pulsed: The pulse value of the outputs is permanently set and corresponds with the last position of the associated display value. Example: Output 1 = energy output Energy display = XXXXX.XX MWh Last position = 0.01 MWh = 10 kwh Output pulse = 10 KWh Page 4 of 7

5 Connections (continued) V 0V t p t p Closing times 400m/s < t p < 600m/s M-Bus: The M-Bus interface complies with the norm EN and operates with 2400 baud fixed. It can be set to 300/9600 baud if necessary. Dimensions 126mm 106mm 54mm Page 5 of 7

6 Display Loops Level 1 Level 2 Energy (main display) Volume Energy at SRD Date SRD Hold down the button (H) until the device switches to another level or switches back from the sub-menu. Volume external counter 1 Pulse value counter 1 SRD value external counter 1 Volume external counter 2 Pulse value counter 2 SRD value external counter 2 Segment test Monthly values input 1 Date month 1 energy consumption Supply temperature Monthly values input 2 Date month val. Input 1 Return temperature Serial number Date month val. Input 1 Temperature difference Customer number Flow Input 1 device number Maximum flow Input 2 device number Instantaneous power Maximum power Page 6 of 7

7 Display Loops (continued) Level 1 Legend Sensor type & installation point Pulse value Press the button briefly (S) to switch through the display from top to bottom. When you have reached the last menu item the device automatically jumps back to the menu item at the top (loop). 1st monthly value heat energy Basic configuration Model number Date battery end Press the button for about 2 seconds (L), wait for the door symbol to appear (upper right corner of the display) and then release the button. The menu is then updated resp. switches to the sub-menu. 1st monthly value input 1 1st monthly value input 2 Time Datum Hold down the button (H) until the device switches to another level or switches back from the sub-menu. M-Bus address Baud rate Input display Error status Software version Page 7 of 7 For the latest information and product updates, register at Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment. Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

zelsius Installation and operating manual All that counts. EnergyMetering

zelsius Installation and operating manual All that counts. EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter with single jet flow sensor M-Bus and 2 inputs/outputs optional qp 0.6/1.5/2.5 m³/h All that counts. General information

More information

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information

More information

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator SensoStar C DE-18-MI004-PTB037 (MID heat) DE-18-M-PTB-0049 (national German cooling)

More information

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication. Data sheet DST2-QHEA-GB0 HMx / 11.05.2016 - V 1.0 Heat meter Q heat 5 Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated

More information

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting. Woltmann type combined energy meter Flanged Woltmann flow meters for large nominal flows, intended for flow measurements in large plants, such as those found in district heating systems. Size DN50 DN300

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They

More information

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h APPLICATION is a fully electronic multi-jets compact heat meter or compact heat and cooling meter with impeller scanning for recording energy and volume data. is equipped with 2 temperature sensors. is

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

WESAN WPV E ELECTRONIC METER WOLTMAN

WESAN WPV E ELECTRONIC METER WOLTMAN APPLICATION Meter for measuring heavily fluctuating flow rates. FEATURES 4 Calibratable and exchangeable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter,

More information

Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications

More information

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing

More information

Supercal 539. Compact thermal energy meter

Supercal 539. Compact thermal energy meter Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling

More information

Compact Static Heat Meter of High-Tech Composite

Compact Static Heat Meter of High-Tech Composite Compact Static Heat Meter of High-Tech Composite Application The Superstatic 789 is a lightweight and robust compact heat meter consisting of a high-tech composite flow meter, a detachable integrator with

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 Data sheet MULTICAL 6L2 Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 M15 0200 Contents Calculator functions 3 Cabinet design 7 Approved meter data 8 Electrical

More information

Measuring capsule heat meter G54 / G55

Measuring capsule heat meter G54 / G55 Measuring capsule heat meter G54 / G55 Measuring capsule heat meter with optical interface and external modules for retrofitting. Thanks to integrated modules, the devices can be equipped with the required

More information

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. revision 04 2015 Woltmann type combined energy meter Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. The WSTH and WPTH meters are designed for flow measurements

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Superstatic 749. Fluidic Oscillation Compact Heat Meter Superstatic 749 Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter an integrator and a pair of temperature sensors.

More information

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0 IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0 Table of contents PRINCIPLE... 4 HOW TO ORDER... 4 TECHNICAL DATA... 5 Table 1.1... 6 Table 1.2... 7 Table 1.3... 7 Straight pipelines lengths... 7 Conveying liquid...

More information

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Fluidic Oscillation Compact Heat Meter of High-Tech Composite Superstatic 789 Fluidic Oscillation Compact Heat Meter of High-Tech Composite Application The Superstatic 789 is an autonomous compact thermal energy meter consisting of a high-tech composite flow meter

More information

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03 s Operating Manual Edition 09/2006 - Revision 03 SITRANS FUE950 Energy calculator type SITRANS FUE950 District heating application Chilled water application Combined cooling/heating application [ ] Order

More information

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement. Hello, I am the new Zelsius C5 heat meter The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement. zelsius C5 Ultrasonic Energy Meter About The ZENNER C5 Ultrasonic

More information

Ultrasonic heat meter

Ultrasonic heat meter Ultrasonic heat meter Installation and user guide Flow sensor-vmc-p Energy integrator Compact heat meter Temperature senor CONTENTS Kapitel Please read this manual prior to installation Page 3 2! T! Important

More information

Infocal 9 Energy calculator for heating and cooling applications

Infocal 9 Energy calculator for heating and cooling applications Installation Guide Infocal 9 Energy calculator for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2018.08 VU.IG.N2.02 1. Installation 1.1. Preparation Only qualified personnel

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, 33659 Bielefeld Phone ++49-521-4048-0 Fax ++49-521-4048-4280 Operating Instruction ServiceJunior SensoControl Please read carefully

More information

Supercal 539 Universal compact heat meter

Supercal 539 Universal compact heat meter n Thermal Energy n Flow Metering n Supercal 539 Universal compact heat meter Universal compact heat meter Result of many years of experience The compact heat meter Supercal 539 is the result of many years

More information

Superstatic 440. Static Heat- and Cooling Meter. Application

Superstatic 440. Static Heat- and Cooling Meter. Application Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

Infocal 9 Energy calculator for heating and cooling applications

Infocal 9 Energy calculator for heating and cooling applications Installation & User Guide Infocal 9 Energy calculator for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2017.03 VUIGN102 1. Installation 1.1. Preparation Only qualified personnel

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

AV-W. Wind Speed and Wind Speed & Direction Sensors

AV-W. Wind Speed and Wind Speed & Direction Sensors Page 1 of 5 AV-W Wind Speed and Wind Speed & Direction Sensors Features: Benefits: Supplied with mounting bracket Wind speed accuracy ±2% Anodized aluminum housing Ideal for naturally ventilated building

More information

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator

More information

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0) Installation & Maintenance Instructions MULTICAL 403 Supplied by.com Call us on +44 (0)118 916 9420 Email info@ Installation and user s guide MULTICAL 403 1 Information Permissible operating conditions

More information

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electrically Released Brakes ERS VAR11-01 FT = 4100 N SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC

More information

MULTICAL 6M2. Data sheet

MULTICAL 6M2. Data sheet Data sheet MULTICAL 6M2 Tailored for mixed fluids Data loggers Info loggers Data backup in case of power failure Measurement at subzero temperatures Configurable fluid type and concentration level Contents

More information

Heating Cost Allocation Valve with local acquisition of the flow temperature

Heating Cost Allocation Valve with local acquisition of the flow temperature 2 823 SYNERGYR Heating Cost Allocation Valve with local acquisition of the flow temperature WRV83... Electronic metering and positioning unit. Measures the flow rate and the temperature differential, calculates

More information

Evaluation Certificate

Evaluation Certificate SC0414-14 Certificate for a part of a measuring system for LOTW Forecourt controller, FuelNet Manager Issued to CODAB AB Höjdrodergatan 24, SE-212 39 Malmö, Sweden In respect of (part of instrument) Forecourt

More information

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only. 9142-B-P-156/AF Field Metrology Well User s Guide Distribution is limited to DoD and U.S. DoD contractors only. May 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change

More information

CORONA E ELECTRONIC METER MULTI-JET

CORONA E ELECTRONIC METER MULTI-JET APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor

More information

SPG-DIGI. Operating Instruction. Please read carefully before use!

SPG-DIGI. Operating Instruction. Please read carefully before use! WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com

More information

System Monitoring SCHOOLMETERBOX AU

System Monitoring SCHOOLMETERBOX AU System Monitoring SCHOOLMETERBOX AU Installation Guide SMETER-IEN084710 98-00013210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Service instructions. MAGNA Series 2000

Service instructions. MAGNA Series 2000 Service instructions MAGNA Series 2000 Magna 32-120, 40-120, 50-60, 50-120, 65-60, 65-120 1 phase 50/60 Hz The pump must be serviced by a qualified person. Service must be carried out in accordance with

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2017 Danfoss VUIGB602 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please visit danfoss.com. 2 Danfoss Energy Meters 2017.03 VUIGB702 Contents 1. Inside the

More information

WZMC-402 Ultrasonic Apartment Energy Meters

WZMC-402 Ultrasonic Apartment Energy Meters Product sheet MT8.36 Meter Type WZMC-402 WZMC-402 Ultrasonic Apartment Energy Meters WZMC-402 is used for metering heat in small and medium-sized central heating plants and district heating plants, typically

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

DALI 650mA LED Driver

DALI 650mA LED Driver Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual RESOL TLR2 Mounting Connection Handling Fault localization *48001550* 48001550 TLR2 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit. B Manual www.resol.de

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

COUNTIS E22 Three-phase energy meter Direct - 80 A

COUNTIS E22 Three-phase energy meter Direct - 80 A Instruction manual COUNTIS E22 Three-phase energy meter Direct - 80 A EN www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings... 4 2.1. Risk of electrocution, burns

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Electronic Heat Meters

Electronic Heat Meters 5 333 WFQ2... WFM2... MEGATRON2 Electronic Heat Meters WFM2... WFQ2... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage

More information

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instruction for Electronic Pressure Switch. Model: PDD Operating Instruction for Electronic Pressure Switch Model: PDD 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

SPC Series. Digital Scale. Operation Manual

SPC Series. Digital Scale. Operation Manual SPC Series Digital Scale Operation Manual Revision 1.0 August 17, 2000 ! WARNING Use only the AC adapter which comes with the scale. Other adapters may cause damage. Internal service to this product should

More information

Operating Instructions

Operating Instructions Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings Safety and use instructions LifeSpeed iq TM - 3-phase chargers ENGLISH SAFETY INSTRUCTIONS GOALS OF THIS MANUAL This manual is aimed at any authorized personnel wanting to use a 3-phase LifeSpeed iq TM

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL TopStick Fixed installation technology LOW VOLTAGE SWITCH PANEL TopDraw plus The modular system solution Quality, Conformity Increased

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

TOPAS PMW-basic. Customer benefits. Product features

TOPAS PMW-basic. Customer benefits. Product features TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration

More information

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

ULTRASONIC METER FOR HEATING AND COOLING SKU-03 AB AXIS INDUSTRIES ULTRASONIC METER FOR HEATING AND COOLING SKU-03 BASIC TECHNICAL DESCRIPTION KAUNAS Contents SAFETY INFORMATION... 1.APPLICATION FIELD... 2.TECHNICAL DATA... 3.OPERATION PRINCIPLE...

More information

GS-AQ1000 VOC Indoor Air Quality Sensors

GS-AQ1000 VOC Indoor Air Quality Sensors Page 1 of 5 VOC ndoor Air Quality Sensors Features: Benefits: Multi-function sensor Fully configurable LCD Display Direct thermistor temperature options available High stability & reliability Long term

More information

DC Energy Measurement for EV Charging Stations

DC Energy Measurement for EV Charging Stations DC Energy Measurement for EV Charging Stations Existing application: railway on-board energy meter Energy Measurement Function (EMF) Voltage measurement (DV) Current measurement (ITC) Application requirements

More information

ULTRASONIC FLOW SENSOR IFX-M4-01

ULTRASONIC FLOW SENSOR IFX-M4-01 ULTRASONIC FLOW SENSOR IFX-M4-01 TECHNICAL DESCRIPTION, OPERATING INSTRUCTION IFX-M4-01 2012-09-10 TABLE OF CONTENTS 1. APPLICATION... 3 2. TECHNICAL DATA... 4 3. PACKAGE CONTENT... 6 4. OPERATING PRINCIPLE...

More information

The electro-mechanical power steering with dual pinion

The electro-mechanical power steering with dual pinion Service Training Self-study programme 317 The electro-mechanical power steering with dual pinion Design and function The electro-mechanical power steering has many advantages over the hydraulic steering

More information

Slide Measuring Instrument GMG 200

Slide Measuring Instrument GMG 200 GTE Industrieelektronik GmbH Slide Measuring Instrument GMG 200 entsprechend DIN 51131 und EN 13893 GTE Ind.Elektronik Helmholtz Str. 38-40 D-41747 VIERSEN Tel.: ++49 - (0)2162 3703-0 Fax.:++49 - (0)2162

More information

AXIAL FANS Axis / Tubo OPERATION MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings.  EATON 1.3.1 CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de

More information

InBin-P Pressure switches 5 Pa Pa

InBin-P Pressure switches 5 Pa Pa InBin-P Pressure switches 5 Pa... 5.000 Pa Electrical binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications Product Information ECN 425 EQN 437 Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications 4/2014 ECN 425, EQN 437 Rotary encoders for absolute position

More information

FMC-1/2 Tina Muting unit

FMC-1/2 Tina Muting unit Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Important instructions

Important instructions Operation manual Please read this manual, before starting the unit. It contains important notes on commissioning and handling. Keep these instructions for future reference. Be careful even if you pass

More information

Bosch Smart Home. Door/Window Contact Instruction Manual

Bosch Smart Home. Door/Window Contact Instruction Manual Bosch Smart Home Door/Window Contact Instruction Manual Start making your home smart! Please be sure to install the Bosch Smart Home Controller first. Please ensure that you have a Bosch Smart Home Controller

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference! Tension Meter S C H M I D T PT Series c o n t r o l i n s t r u m e n t s Edition PT 01.0.E Model PT-100 PT-100-L Instruction Manual Valid as of: 15.04.2011 Please keep the manual for future reference!

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information