Master Slave Converter [ VAC & VAC]

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Master Slave Converter [ VAC & VAC]"

Transcription

1 Master Slave Converter [ VAC & VAC] Contents: Installation...1 Wire Diagram...4 Exploded View...6 Intended Use: To provide simultaneous operation of up to five Midmark compressors connected to a common operatory air supply line. Note: Low voltage control is required on the designated master compressor only. Language of origin: English Step 1: Install power supply. A) Select which compressor will be the master. Midmark recommends the compressor with the least amount of run hours should be the master. B) Verify voltage on master compressor matches voltage on master slave converter box. Refer to wire diagrams in this manual. C) Shut off main power supply to all compressors. D) Mount master slave converter box if desired. E) Remove compressor electrical box cover. F) Drill 13/16 hole on left side of compressor electrical box. G) Install conduit through 13/16 hole and connect to one of the on/off switches in the compressor electrical box as shown. H) Connect ground wire to ground screw in compressor electrical box. I) Install compressor electrical box cover. Note: If mounting master box is desired, mount box close enough to the compressor electrical boxes for cables and power supply conduit will reach connections. Mounting screws are not included. The compressor you connect the conduit to will be considered the master compressor. 13/16 Drilled Hole Conduit On / Off Switch Ground English Rev. A (7/12)

2 Low Voltage Wires on Back of Compressor Control Box Step 2: Install slave cables to all slave compressors. A) Remove wire nut from low voltage wires on back of compressor electrical box. B) Connect one master slave converter box cable to low voltage wires, Red to Red and Black to Blue. C) Repeat A) and B) for each compressor your connecting to the master slave converter box. D) Install a wire nut on each master slave converter box cable wire not being used. E) Turn main power supply on for each compressor. Note: Master compressor will be the only one that stays connected to remote switch (Master Control Panel) in operatory. Slave Cable from Master Slave Converter Box English-2

3 Step 3: Adjust slave compressor pressure switches. A) Adjust pressure switches in the slave compressors, not the master compressor, to ensure the switch stays closed through cycle. Midmark Brands... B) Remove pressure switch cover. C) Turn adjustment nut clockwise until switch stays closed through cycle. D) Install pressure switch cover. E) Restore power to compressors. Note: The master compressor is the one you connected the master slave converter conduit power supply to in step 1. Midmark PowerAir Pressure Switch Adjustment Nut Shown Note Older style Midmark compressors may only have two wires in pressure switch. English-3

4 Master Slave Converter Box Wire Diagram 115 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH Transformer Ground OR GN English-4

5 Master Slave Converter Box Wire Diagram 230 VAC Contactor Master Slave Converter to Slave Compressors Master Slave Converter Conduit Power Supply To Master Compressor YL BL WH OR Transformer Ground GN English-5

6 Serial Numbers / Dates: all Service Parts Item Description Qty. 1 Screw, Panhead, ( x.500) 4 2 Dim, Rail 1 3 Transformer, 240V / 115V 50/60/HZ 1 4 Nut Keps with tooth lock washer, ( ) 4 5 Contactor 1 English-6

PowerMax Surgical Suction Producers

PowerMax Surgical Suction Producers PowerMax Surgical Suction Producers Models: PM-1, PM-3, PM-4 Installation & Operation 10496800 Rev. B Table of Contents Section 1 About PowerMax...1 Section 2 Specifications & Model Selection...3 2.1

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36 Master Series Gas XPress Grill Parts List Models, Non-CE & CE Versions: XG24 XG36 Document Number: G_GHD_PL_XPRESS_XG24ANDXG36 (rev 3 updated: /6) Cooking Zone Designation The Xpress Grill is a cooking

More information

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216 SOLAR-150HD 150-Watt Dual Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 731-5869 FAX 904 733 0012 Toll Free 800-684-6404 TABLE OF CONTENTS Page

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Electrical Requirements: 24 VAC, 3.2 Amp 13VAC, 2 Amp Attention These instructions apply to Midmark cabinetry. For other

More information

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx] Elevance Product Name Chair Conversion Kit (to LR Delivery Unit) Installation Installation [Kit #002-1966-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance LR mounted

More information

B to A Solenoid Adapter Kit Installation & Troubleshooting Guide

B to A Solenoid Adapter Kit Installation & Troubleshooting Guide B to A Solenoid Adapter Kit Installation & Troubleshooting Guide English B to A Solenoid Adapter Kit Thank you for purchasing a Rain Bird B to A Solenoid Adapter Kit. This durable solenoid assembly provides

More information

PowerVac G. Service and Parts Manual G3 G5 G7 G6 G10 G14. Model Numbers: Single Vac Units. Twin Vac Units FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY

PowerVac G. Service and Parts Manual G3 G5 G7 G6 G10 G14. Model Numbers: Single Vac Units. Twin Vac Units FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY PowerVac G Model Numbers: Single Vac Units G3 G5 G7 Service and Parts Manual Twin Vac Units G6 G10 G14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY 004-0790-00 (10/3/17) 2010 Midmark Corp. 60 Vista Drive

More information

255 LED Light Dual Conversion Installation [9A584001]

255 LED Light Dual Conversion Installation [9A584001] 255 LED Light Dual Conversion Installation [9A584001] Note Two single ceiling lights are needed. The ceiling must be capable of supporting the double light system. Weight (max.): 118 lb (53.6 kg); Torque

More information

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual 1610131300 Rev B 17Jun2017 1 Fig. 1.1 DIM S INCH [MM] Fig. 1 Designed for maximum sanitary use, the 8374 Automatic Roll Towel Mechanism automatically

More information

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems. Capstone Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA Telephone: (818) 734-5300 Facsimile: (818) 734-5320 Website: www.microturbine.com Work Instructions Commissioning Checklist

More information

Junction Boxes. Common Components Air / Water Control Valves. Contoured Junction Box. Small Junction Box. Elevance Junction Box

Junction Boxes. Common Components Air / Water Control Valves. Contoured Junction Box. Small Junction Box. Elevance Junction Box 7 8 7 8 8 Junction Boxes Common Components...-89-99 Air / Water Control Valves Contoured Junction Box DAi Small Junction Box Elevance Junction Box TP Rev. A Square Junction Box (optional) Camera Junction

More information

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

Installation, Operation, and Maintenance Manual. Automatic Fire Damper Installation, Operation, and Maintenance Manual Automatic Fire Damper Part # 458295 Designed to close in fire situations. Reset by activating the reset switch. UL Listed Constructed in Accordance with

More information

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators Installation Sheets Manual 121 Relays and Contactors Section R Technical Bulletin R81EAA Application R81 plug-in electronic

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Reduced-profile, single-circuit trac sections for surface or pendant mounting. Compatible with a full range of feed, connector

More information

HLS Watt Halogen Illuminator Service Manual

HLS Watt Halogen Illuminator Service Manual HLS-150 150-Watt Halogen Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 737 7611 FAX 904 733 4832 Toll Free 877 677 2832 (English) TABLE OF CONTENTS Page

More information

Service Guide: Power Supply Model

Service Guide: Power Supply Model Service Guide: Power Supply Model 153808 The Power Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents:

More information

Wiring Diagrams: 255 LED Light

Wiring Diagrams: 255 LED Light Wiring Diagrams: 255 LED Light Attention This document contains wiring and/or tubing diagrams for the models listed in the table below. Locate the desired model / serial number, then click on the blue

More information

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 The M9208-xxx-x Series Electric Spring Return Actuators provide control of dampers in Heating,

More information

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect

More information

Canis Major Veterinary Tables

Canis Major Veterinary Tables Go To Table Of Contents Next Canis Major Veterinary Tables Model Numbers: CMWO Service and Parts Manual CMWS CMDT-45 CMDT-WS-45 CMDT-60 CMDT-WS-60 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY SF-10 Style

More information

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS Description Control board installation procedures are described in detail in these instructions. Read and follow these instructions carefully before

More information

Installation Manual WAV Version WAV HBX Control Systems Inc. Page 1

Installation Manual WAV Version WAV HBX Control Systems Inc. Page 1 Installation Manual WAV-0100 04 WAV-0100 HBX Control Systems Inc. Page 1 Control Systems Inc. HBX WAV-0100 Wireless Outdoor Sensor Table of Contents Introduction 3-5 o Getting Started... 3 o Safety Symbols

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Chicago Pneumatic Oil-injected rotary screw air compressors

Chicago Pneumatic Oil-injected rotary screw air compressors Chicago Pneumatic Oil-injected rotary screw air compressors CPA 7.5, CPA 10, CPA 15, CPA 20 Parts list 2014 05 Chicago Pneumatic 2 2205 7115 24 Chicago Pneumatic Oil-injected rotary screw air compressors

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Crane Control Class 5010

Crane Control Class 5010 WB F s and Rectifiers Catalog CONTENTS Descriptions....................................................Page DC Magnetic Drum s General Information................................................. 14 Pricing

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS

CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVENS MODELS VC4GS VC4GD VC4GC VC6GS VC6GD VC6GC ML-126610 ML-126611 ML-136494 ML-126612 ML-126613 ML-136495 For additional information on Vulcan-Hart or to

More information

Service and Parts Guide: Matrx Central Scavenger Waste Anesthetic Gas Disposal System

Service and Parts Guide: Matrx Central Scavenger Waste Anesthetic Gas Disposal System Service and Parts Guide: Matrx Central Scavenger Waste Anesthetic Gas Disposal System Applies to Models: All veterinary anesthesia machines. warning Equipment is not suitable for use in the presence of

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

Finish: Stainless Steel

Finish: Stainless Steel miniport LED Indoor/Outdoor : Miniport LED is slim and can be recessed into a wall or floor using a MiniPort junction box, which mounts to an octagon box or outdoor, wet-location electrical box. The fixture,

More information

SECTION 3. PARTS INFORMATION INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny merchandiser.

SECTION 3. PARTS INFORMATION INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny merchandiser. SECTION. PARTS INFORMATION -1. INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny merchandiser. -2. GENUINE PARTS Use only genuine Henny Penny parts in your cabinet.

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

MAZDA 3 AUTOMATIC CRUISE CONTROL INSTALLATION INSTRUCTIONS

MAZDA 3 AUTOMATIC CRUISE CONTROL INSTALLATION INSTRUCTIONS 250-9009 08-09 MAZDA 3 AUTOMATIC CRUISE CONTROL INSTALLATION INSTRUCTIONS SERVICE PART NUMBERS ITEM QTY DESCRIPTION PART NUMBER 1 1 CONTROL MODULE 250-2746 2 1 MAIN HARNESS 250-2712 3 1 ECM HARNESS 250-2747

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

G2.1 RETROFIT LED LIGHTING

G2.1 RETROFIT LED LIGHTING INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation

More information

Go Digital! Advanced Conscious Sedation Systems. Digital Precision and Safety. Clearing Your Work Space. Technology for the Future.

Go Digital! Advanced Conscious Sedation Systems. Digital Precision and Safety. Clearing Your Work Space. Technology for the Future. Advanced Conscious Sedation Systems YEARS OF INNOVATION Go Digital! Flowmeters: Digital Percentage Conventional Latex Free Rubber Goods Digital Precision and Safety Systems: Central Portable Enclosed Portable

More information

Installation Instructions

Installation Instructions Smart Start Assist Kit For use with Single-Phase Residential Geothermal Heat Pumps 8-733-934-497 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI

More information

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment

More information

LR Resistance Heater Units

LR Resistance Heater Units 1 These instructions contain operating information and should be left with the unit. LR Resistance Heater Units Part List Edition 3.0 Installation in countries covered by EC Directives: This product will

More information

Pivot Point Lite Wiring Manual

Pivot Point Lite Wiring Manual 2009-10 Pivot Point Lite Wiring Manual (small square single circuit board design) Section 1 Pages 2-3 Pivot wiring to monitor and/or stop the irrigation system. Section 2 Page 4 Section 3 Page 4 Simple

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual

A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual Steady-Burning Red LED Obstruction Light FAA Type L-810 115 / 230 Vac, 50 / 60 Hz (input) A-L810 Red LED Obstruction

More information

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004 Replacement Parts List 110502500 Revision C 02/2017 McQuay Console Water Source Heat Pump European Unit WWME, WWMJ, WWMK, WWML 007-015 Designs A, B (1, 2) Last Manufactured: 2004 To find your Daikin Applied

More information

Removal of the High Pressure Fuel Rail Feed Lines

Removal of the High Pressure Fuel Rail Feed Lines 18SP698 EPA07/10 Three-Filter Fuel System DD15/16 High Pressure Fuel Feed Lines, Mounting Bracket, Vibration Dampers and P-clips Service Kit (P/N: A4720707932) PERSONAL INJURY All parts provided within

More information

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC REVERSE OPERATION & MASTER / SLAVE CONNECTIONS MAINTENANCE

More information

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC ML-136043 208/240 V. 8.5kW ML-136045 480 V. 8.5kW 3-PAN PRO ML-136037 208/240 V. 9.25kW ML-136044 480 V. 9.25kW ML-152030 3-PAN LWE 5-PAN BASIC

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing

More information

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS KAC-30 TECHNICAL EDUCATION 36 & 48 ISLAND AND WALL CANOPY RANGE HOODS JOB AID 4317332 FORWARD This Job Aid, KitchenAid 36 and 48 Island And Wall Canopy Range Hoods, (Part No. 4317332), provides the technician

More information

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JUNE 12, 2017 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the

More information

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992 Replacement Parts List No. 110502800 Revision A 02/2006 McQuay Water Source Heat Pump Replacement Chassis VF 100-330 Vintage H Last Manufactured: 1992 To find your Daikin Applied parts distributor, call

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Medium & Heavy Duty Swing Gate Operators Models: SW470 SW490 2 Contents Contents General Information 4 Parts Supplied 4 Model Classifications 4 Specifications

More information

NT-300 Series Single Circuit Track System & Accessories

NT-300 Series Single Circuit Track System & Accessories NT-300 Series Single Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral copper conductors.

More information

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,

More information

Master Series Half Size Electric Convection Oven

Master Series Half Size Electric Convection Oven Master Series Half Size Electric Convection Oven Parts List Models: MCO-E-5-C MCO-E-25-C from serial# 0623000000 (0-JUNE-) -844-724-CARE www.mtwkitchencare.com G_EO_PL_CONVECTION_MCOE5C (rev 5 7/207) Rating

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

LyteLaunch Dry - Wet and DMX Models. Operation Manual

LyteLaunch Dry - Wet and DMX Models. Operation Manual LyteLaunch -150 Dry - Wet and DMX Models Operation Manual LyteLaunch 150 Introduction Thank you for purchasing the LyteLaunch 150 from Advanced Lighting Systems, Inc. This fiber optic lighting illuminator

More information

Single & Three-Phase Soft Starters

Single & Three-Phase Soft Starters Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature

More information

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7 MU 03.04.MMMREV.2 09/01 UNI EN ISO 9001 ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7 ENGLISH 1. GENERAL 2. INSTALLATION MECHANICAL FIXING ELECTRICAL CONNECTIONS HOW TO CHOOSE the

More information

Installation and Operation Instructions

Installation and Operation Instructions Peerless Pump Company PJPC Jockey Pump Controllers Installation and Operation Instructions Peerless Pump Company 2005 Dr. M. L. King Jr. Street Indianapolis, IN 46202 Bulletin 4857341 Rev. December 21,

More information

Butterfly Valve Retrofits

Butterfly Valve Retrofits Butterfly Valve Retrofits Contents How to Select the Butterfly Retrofit Solution... pg 127 Butterfly Valve Retrofit Actuators... pg 128 Solutions for Specific Manufacturer and Part Number Apollo... pg

More information

CHAPTER 4 PARTS PARTS BY PICTORIAL. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.

CHAPTER 4 PARTS PARTS BY PICTORIAL. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. CHAPTER 4 PARTS PARTS BY PICTORIAL This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description for Serial

More information

Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual

Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual Series PRV-71H Pressure Reducing Valve Operation and Maintenance Manual All Hydro Instruments Chemical Feed systems are carefully designed and tested for years of safe, accurate field service. All Hydro

More information

RENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813)

RENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813) VARIABLE SPEED DRIVE RENEWAL PARTS Supersedes: 160.00-RP4 (1012) Form 160.00-RP4 (813) 292 HP 50 HZ, 400VAC (P/N 371-03700-XXX) 351 HP 60 HZ, 460VAC (P/N 371-02767-XXX) 419 HP 50 HZ, 400VAC (P/N 371-03789-XXX)

More information

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com G_EO_PL_CONVECTION_MCOESED0FROM0004CJ000 (Rev2) Explanation of Serial Number Identification

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 03/6/4 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

Troubleshooting Guide: 255 LED Light

Troubleshooting Guide: 255 LED Light Troubleshooting Guide: 255 LED Light Note Use only factory replacement lights (refer to parts list for order number). Caution Carefully handle parts near membranes and wire harnesses. Allow the light to

More information

PART 1 / LIFTING CARRIAGE ITEM QTY ART.nr. DESCRIPTION PRICE IN EURO. PART 2 / COLUMN ITEM QTY ART.nr. DESCRIPTION PRICE IN EURO

PART 1 / LIFTING CARRIAGE ITEM QTY ART.nr. DESCRIPTION PRICE IN EURO. PART 2 / COLUMN ITEM QTY ART.nr. DESCRIPTION PRICE IN EURO HDL- 7500 SPARE PART LIST / 2005 PART 1 / LIFTING CARRIAGE ITEM QTY ART.nr. DESCRIPTION PRICE IN EURO 1 1 WK01 Carriage 2 2 WK02 Gliding piece (short) 3 4 WK03 Screw, M6 4 2 WK04 Gliding piece (long) 5

More information

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy 200 w/s 400 w/s Guide Number (m/100iso) 42 60 Recycling Time (100%) 0.3 ~ 0.9 sec 0.4 ~ 1.6 sec Flash Duration 1/700 ~ 1/1700 sec 1/700 ~ 1/1700

More information

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled

More information

AUTOMATIC GATE LOCK. Installation Manual

AUTOMATIC GATE LOCK. Installation Manual IMPORTANT: Before you install the automatic gate lock be sure your gate is level, moves freely on its hinges, and does not bind or drag against the ground. AUTOMATIC GATE LOCK Installation Manual PLEASE

More information

60Hz UP6 15, UP6 20, UP6 25, UP6 30

60Hz UP6 15, UP6 20, UP6 25, UP6 30 60Hz UP6 15, UP6 20, UP6 25, UP6 30 en fr pt es PARTS CATALOGUE CATALOGUE DE PIÈCES DÉTACHÉES LISTA DE PEÇAS LISTA DE REPUESTOS zh C.C.N : 80445166 REV. : A DATE : OCTOBER 2008 CONTENTS Page T N o Page

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS VC4G & VC6G GAS CONVECTION OVENS VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD., BALTIMORE, MD 21222 FORM 43031 Rev. L (January 2018) F-43031

More information

1329I Integrated Drive/Motor CE Filter Option Kit

1329I Integrated Drive/Motor CE Filter Option Kit Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING The Model RPC30 (-LON) Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number: ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300 Part Number: 9 1210 00 106 Publication Number: 9 1210 00 993 Date: July, 1993 Revision F: July, 1996 WARNING To prevent personal injury or equipment damage,

More information

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102 INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL-15 CONTENTS GENERAL...2 NOTES, CAUTIONS AND WARNINGS........... 2 REFERENCE...2

More information

Spreader and Vehicle Battery Kits

Spreader and Vehicle Battery Kits May 5, 20 Lit. No. 922, Rev. 04 and Vehicle Battery Kits Hopper s Parts List and Installation Instructions CAUTION Read this document before installing the and Vehicle Battery Kit. CAUTION Use standard

More information

OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY. MODEL MP-3913 WITH MP-2002 Control

OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY. MODEL MP-3913 WITH MP-2002 Control OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY MODEL MP-3913 WITH MP-2002 Control EFFECTIVE S.N. 18225 May 6, 2002 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification 1.3

More information

USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English

USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English USER MANUAL MODEL NUMBER: FST FSTK FSTV Flooded Suction Tank English WARNING Read this manual completely and understand the machine before operating or servicing it. Read all instructions before installing

More information

Replacement Part Diagrams SG12 Series Surface Grinder

Replacement Part Diagrams SG12 Series Surface Grinder Replacement Part Diagrams SG Series Surface Grinder SG GrinderS FOrM GOMxxxxxxxx, VerSiOn.0, AUTHOriZATiOn: xxx, PAGe: Frame Assembly SG/E Surface Grinder SG GrinderS FOrM GOMxxxxxxxx, VerSiOn.0, AUTHOriZATiOn:

More information

CONNECTOR/GROUND/SPLICE LOCATION

CONNECTOR/GROUND/SPLICE LOCATION AN 8W-91 CONNECTOR/GROUND/SPLICE LOCATION 8W-91-1 8W-91 CONNECTOR/GROUND/SPLICE LOCATION TABLE OF CONTENTS page CONNECTOR/GROUND/SPLICE LOCATION DESCRIPTION...1 CONNECTOR/GROUND/SPLICE LOCATION DESCRIPTION

More information

Razor TM 20 / 20T. PARTS LIST Kent models: (2)

Razor TM 20 / 20T. PARTS LIST Kent models: (2) Razor TM 20 / 20T PARTS LIST Kent models: 9087200020 9087201020 2007-06 TABLE OF CONTENTS RAZOR TM 20-20T 1 DESCRIPTION PLAN GENERAL VIEW 2-3 SOLUTION TANK 4-5 RECOVERY TANK 6-7 CHASSIS SYSTEM 8-9 WHEEL

More information

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators OpenAir GCA Series Spring Return 4 lb-in Electronic Damper Actuators EA GCA- Description The OpenAir 4 Vac/dc spring return 4 lb-in electronic actuator is designed for digital or analog control of building

More information

Model Year: 2010 Model: 4Runner Doc ID: RM000003YMG002X. Title: INTRODUCTION: REPAIR INSTRUCTION: CUSTOMIZE PARAMETERS (2010 4Runner)

Model Year: 2010 Model: 4Runner Doc ID: RM000003YMG002X. Title: INTRODUCTION: REPAIR INSTRUCTION: CUSTOMIZE PARAMETERS (2010 4Runner) INTRODUCTI: REPAIR INSTRUCTI: CUSTOMIZE PARAMETERS (2010 4R... mhtml:file://c:\documents and Settings\mike.cordeaux\Desktop\INTRODUCTI REPA... Page 1 of 11 Last Modified: 10-26-2009 6.2 D From: 200908

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

Item Number Description Quantity

Item Number Description Quantity Figure 1: VisionAire Main View CA80-1 CABINET, FRONT PANEL ASSY (VISIONAIRE 5) 1 1 CA80- CABINET, FRONT PANEL ASSY, W/O MONITOR (VISIONAIRE 5) 1 1 CA85-1 CABINET, FRONT PANEL ASSY (VISIONAIRE 3) 1 1 CA85-

More information

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control

More information

Lectrotab Retrofit Instructions

Lectrotab Retrofit Instructions Lectrotab Retrofit Instructions (Replacing Bennett Standard System) Old New Standard Bennett Actuator (A1101A) Standard Lectrotab Actuator (A-BK) Ph: 804-261-3888, Fax: 804-264-3070, www.lectrotab.com

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS ELECTRIC CONVECTION OVENS DEC5 HEC5 HEC5D HEC5X HEC5DX ML-126749 ML-126750 ML-126751 ML-126753 ML-126754 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM

More information