PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

Size: px
Start display at page:

Download "PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS"

Transcription

1 PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS Description Control board installation procedures are described in detail in these instructions. Read and follow these instructions carefully before replacing the control board. Failure to do so may result in control board damage. Electrostatic Discharge (ESD) Precautions Before removing the new control board from the static wrap, it is very important to discharge any static electricity. This can be accomplished in two methods. Servicer can wear a ground strap or by touching the metal chassis before replacing the board. Important Note: Damage to the control board can occur from failure to disconnect power supply or failure to set the master switch (located on the control board) to OFF before removing the low voltage terminal strip cover from an installed control board. Damage to this board by not following these instructions is considered misuse and not covered under either the standard unit warranty or any extended service contract. Important Note: All warranty replaced boards must be returned to the parts source from which they were purchased to insure proper warranty credit. Existing Control Board Removal Procedures. Disconnect power to the unit by unplugging the power cord at the wall outlet or subbase, or disconnect power at the fuse box or circuit breaker. 2. If the cabinet front is screwed to the chassis, remove the /4 screw (or screws) located behind the inlet grille. Pull the inlet grille forward from the top of the grille to access screw(s). FRONT MOUNTING HOLE Figure RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation. Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use. Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety practices...follow them. The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence. IO-660A November 2006 Printed in USA

2 ON 2 LOAD COM Remove cabinet front from chassis by tilting the bottom of the front forward, lifting slightly up and forward. 4. If a remote thermostat or any low voltage accessory is being used, remove the low voltage pin connector from the low voltage terminal strip. If a previous version board is being replaced remove wires from the low voltage terminal strip. PULL TO REMOVE THERMOSTAT KNOB PULL TO REMOVE MODE SWITCH KNOB Lift Off ESCUTCHEON SCREW (2) SCREW 2. The external transformer will come with the Black 7 wires connected to the LOAD terminal of the transformer (LOAD terminals are the low voltage terminals) and the Grey 22 wire connected to the COM terminal on the transformer. The Grey 2 wire will need to be connected to the 20 or 265 volt tap on the transformer. Place the control panel back on its hinges. NOTE: Refer to the serial plate for voltage information.. Install the new board and reinstall the screws removed in step # Using the insulated terminals connect the two (2) Black 7 wires from the Load terminals on the transformer to the 24VAC Transformer terminals on the control board. See Figure 4. 5.Connect Grey 22 wire from the COM terminal on the transformer to line 2 on the control board. Connect Grey 2 wire from the transformer to line on the control board. TRANSFORMER Figure 2 5. Remove knobs and escutcheon. 6. Remove the two mounting screws, one on each side of control board cover. Some models may have a screw on the lower right side of the control panel that will need to be removed. Tilt control panel out and remove cover. 7. Remove the wires from the board in the unit, including Thermistor Sensors if they plug into the board. 8. Remove the four screws holding the board and remove the old board. Figure New Control Board Installation Procedures TRANSFORMER LINE GY22 GY2 LINE ER ER 2 LINE 2 COMPRESSOR 9. If existing unit has a remote mounted off board transformer for board power, proceed to Step. 0. Lift the control panel up so the control panel is free of its hinges. Orient the control panel so there is easy access for mounting components to the inside of the control panel.. Using the two #8 screws that are provided, screw the transformer that was provided with the kit to the control panel in the transformer mounting holes provided in the panel. See Figure. 2 24VAC~TRANSFORMER 2VA CLASS 2 ONLY Figure 4

3 6. Thermistor Temperature Sensors Installation A. It is recommended that the Indoor Discharge Thermistor (with the wires) be installed but it is optional. If you chose not to install this sensor, the green status light will remain illuminated continuously. For status light functionality, the thermistor MUST be installed. Instructions are as follows: A. Carefully cut and remove the gasket on the left and right sides of discharge screen. Remove the two (2) 5/6 screws holding the indoor exhaust screen above the indoor coil. Remove the indoor exhaust screen. Remove the two (2) /4 screws connecting the heater panel to the evaporator coil. Remove the two (2) screws mounting the air baffle to the top of the heater panel and remove and discard the air baffle. A2. Install the new air baffle. Route the yellow thermistor probe from right to left through the wiring tube enclosure. Mount the black tip of the yellow thermistor probe in the plastic clip provided. Hold the plastic clamp in place and secure the clamp to the left end of heater panel using one of the original screws. Replace the screw on the right end of the air baffle being careful not to damage the wiring insulation on the probe. A. Replace the heater panel, routing the yellow wire around the right end of the heater panel and into the control panel pulling snug to prevent the wire from being entangled in the blower wheel or being visible from above. Replace the two screws mounting the heater panel to the evaporator coil. A4. Replace the exhaust grille and two mounting screws. A5. Connect the yellow wire using the plug-on connector to the new board on the IDT (yellow) terminals. B. If the existing Indoor Ambient Thermistor (with the BLACK wires) was connected to the board by a plugon connector, reconnect it to the new board on the IAT (black) terminals. If the existing Indoor Coil Thermistor was soldered to the previous board, install the new black thermistor per Figure 6 and connect as above. Clip is designed to be pushed into the coil between the aluminum fins and attach over two (2) screws. CLAMP END OF THERMISTOR SECURELY PLASTIC CLAMP WIRE ENCLOSURE ROUTE THERMISTOR THROUGH TUBE ON BLOWER EXTENSION THERMISTOR Figure 6 Figure 5

4 C. If the existing Indoor Coil Thermistor (with the RED wires) was connected to the board by a plug-on connector, reconnect it to the new board on the ICT (red) terminals. If the previous board used indoor coil bi-metals, remove and discard the bi-metal devices. The access door will need to be removed on the indoor coil to gain access to the bi-metal. See Figure 6. The Indoor Coil Thermistor will need to clip on the vertical section of the 90-degree bend of the inlet line to the indoor coil. See Figure 7. Connect the Indoor Coil Thermistor to the board as noted above. D. If the existing Outdoor Coil Thermistor (with the BLUE wires) was connected to the board by a plugon connector, reconnect it to the new board on the OCT (blue) terminals. If the previous board used indoor coil bi-metals, remove and discard the bi-metal devices. The Indoor Coil Thermistor will need to clip on the crossover tube shown in Figure 8. There will be two clips supplied in the kit for the Blue Thermistor. One clip as supplied on the sensor will fit 5/6 tubing used on the bent coil, and an additional clip (loose in the bag) will fit /8 tubing used on the flat slab coil. If you have a slab coil, you will need to remove the 5/6 clip from the sensor and replace it with the /8 tube clip. Connect the Outdoor Coil Thermistor to the board as noted above. Outdoor Coil Thermistors are only used on Heat Pump models; DO NOT INSTALL THIS SENSOR IF THE UNIT IS NOT A PUMP. Figure 8 Cross over tube for 9,2 and 5k or center tube for 7,000 BTU 7. If the unit has a condensate pump, go to step 8. If the unit has a power vent or power door, go to step 9. Otherwise proceed with step 20. Refer to wiring diagrams in back of manual. 8. Condensate Pump Units Only (See Wiring Diagram Page 0 Reconnect the wires across the top terminals of the control board. Connect as follows: Red to Line Brown 4 to Heater Brown 4 to Heater 2 Power cord (or black 8) to Line 2 Violet 2 and Yellow to Compressor Black 6 to Fan High Red 7 to Fan Low 9 from reversing valve and Yellow to Rev. Valve. Connect the yellow 5 wire to the 20 or 265-volt terminal as applicable using the piggyback terminal on the yellow 5 wire. Go to step 2. Figure 7 INDOOR COIL THERMISTOR - RED All Units Connect to ICT on Control Board 4

5 9. Power Vent/Power Door Units Only (See Wiring Diagram Page 9) Reconnect the wires across the top terminals of the control board. Connect as follows: Red to Line Brown 4 to heater Brown 4 to Heater 2 Power cord (or black 8) to Line 2 Violet 2 to Compressor Blue 4 to Fan high Blue 5 and Blue 0 to Fan Low 9 from reversing valve to Rev. Valve Connect the white 7 wire to the 20 or 265-volt terminal as applicable using the piggyback terminal on the white 7 wire. Go to step Reconnect the wires across the top terminals of the control board. Connect as follows: (See Wiring Diagram Page 8) Red to line Brown 4 to heater Brown 4 to heater 2 Power cord or black 8 to line 2 Violet 2 to compressor Black 6 to Fan High Red 7 to Fan Low 9 from reversing valve to Rev. Valve. 2. If a remote wired thermostat and an additional REK0B escutcheon that states THIS UNIT IS CONTROLLED BY WALL MOUNTED THERMOSTAT is used, the knob and potentiometer will need to be removed. To remove the knob, loosen the set screw on the side of the knob with a flat screwdriver and pull knob from potentiometer shaft. To remove the potentiometer, loosen the nut with a 0mm driver and remove the nut and 2 washers. Pull the shaft free of the panel. Reassemble potentiometer, washers, nut and knob and store for future use. These will be required if the unit is ever converted back to local controls instead of wired thermostat operation. The control board cover is now ready to be installed. The ribbon for the touch pad will need to be connected to the control board. Take caution not to bend or fold the ribbon (See Figure 9 for ribbon connection). Install orange connector from the thermostat on the touch pad to the IHD Terminals on control board, unless the knob has been removed. Ensure that no wires are pinched or caught between the cover and the panel and then reinstall the screws removed in Step If a remote thermostat or any low voltage accessory is being used connect the low voltage pin connector to low voltage terminal strip. If replacing a previous version board you will need to use the 8 pin connector supplied with the board for low voltage accessories. Wires supplied with this kit have terminal ends on the wires. Insert the terminal end into the correctly labeled slot, push in and it will lock in place. After loading pin connector use the wire nuts supplied with the kit to wire nut the new wires onto the existing wires supplied for low voltage accessories. See Figure 9 on page Set the master switch to ON. Restore electrical power and verify unit functionality. 24. This control can be configured for several operational features. A. If the unit was being controlled by a wired wall thermostat, the board will have to be configured to allow the thermostat to operate the unit. To configure for a wired wall thermostat, press and hold the SPEED button and press the COOL button twice. The light in the bottom left hand corner below the OFF light will blink twice to confirm that the configuration was successful. Repeat step 24 if the light did not blink. B. If the unit will be controlled by a wireless thermostat (Goodman DS0A using DT0A antenna on the unit), the board may have to be configured to allow the wireless thermostat to operate the unit. To configure for wireless operation, press and hold the SPEED button and press the button twice. The light in the bottom left hand corner below the OFF light will blink twice to confirm that the configuration was successful. Repeat step 24 if the light did not blink. C. If constant fan is desired, the unit will need to be configured by pressing and holding the button and pressing the OFF button twice. To revert to auto/ cyclic fan operation, press and hold the COOL button and press the OFF button twice. D. Other configuration items exist, but can only be accessed over the wireless antenna to a wireless site platform (Goodman DP0A). E. To reset all the configuration items back to the factory defaults, turn the master switch off for 0 seconds, and then hold the and COOL button while turning the master switch back on. 25. Replace the front in reverse order as removed in Steps 2 and. 5

6 BROWN BLACK w/white STRIPE w/black STRIPE RED GREEN WHITE BLUE GREEN w/ STRIPE Remote Thermostat *Only load wires needed for accessories attached to unit. Figure 9 6

7 REV. LINE HIGH LOW RIBBON CONNECTOR DSI IN GL B GH BLACK ORANGE from Touch Pad BLUE Heat Pump models ONLY. Must not be used on PTC models. RED 24VAC-TRANSFORMER ON Left is ON Position Figure 0 7

8 WIRING DIAGRAMS REMOTE THERMOSTAT OPERATION COOLING UNIT W/ELECTRIC CONNECT FUNCTION R TO: OFF PUMP W/AUXILIARY ELECTRIC CONNECT FUNCTION R TO: OFF ST STAGE ANTICIPATOR CURRENT:. 2ND STAGE ANTICIPATOR CURRENT:. WIRING DIAGRAM REV.0 G G COOL G, Y/W COOL G, Y/W * ST STAGE 2ND STAGE G,B,Y/W G, W2 * FOR A PUMP THERMOSTAT USED ON A STRAIGHT COOL UNIT H C F YL0 OD /COMP CAP RD HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 7 TRANSFORMER 20 X LOAD VAC~TRANSFORMER 2VA CLASS 2 ONLY X COM E E2 RD LINE E GY2 ELECTRIC ER ER ER 2 RIBBED 2 WIRE G N GY22 LINE 2 BK8 S 5 C R FUSE COMPRESSOR BK6 HIGH BR4 RD7 LOW 20 RE V SOLENOID E2 E E4 E5 E6 E7 E8 E9 E0 K4 K5 K6 CP4 BR4 BR4 CR P2 COMP VT2 P5 WH5 MOTOR 9 REV K K2 K P P4 X4 IDT GREEN X2 P9 ICT RED P8 OCT BLUE ORANGE SW2 P0 P P M ON / OFF MASTER SWITCH COM A COM B DS DS2 MS MS2 EH IN LS FD FD2 TF- TF+ C R GL W2 Y/W B GH AUXILIARY REMOTE THERMOSTATE IAT BLACK M2 6 NOTES: WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED (FOR 265V) AND GROUNDED. 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN ON PUMP MODELS ONLY. 4 ON UNITS WITH FRONT DESK CONTROL SWITCH. 5 BK8 ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V. FOR 20V & 5 V, CONNECT POWER CORD TO LINE 2. 6 FOR REMOTE OPERATION, SEE CONFIGURATION CHART. 4 FRON T DESK SWITCH USE COPPER CONDUCTORS ONLY GN CHASSIS CONTRO L PANEL WIRE LEGEND 7 IF SUPPLY VOLTAGE IS 208V/20V USE THE 20V TAP ON TRAN SFORMER. IF SUPPLY VOLTA GE IS 265V USE THE 265V TAP ON TRANSFORMER. 5V TRANSFORMER NOT SHOWN. HIGH VOLTAGE (FACTORY) HIGH VOLTAGE (FACTORY OR FIELD) 8 FOR CONTINUOS OPERATION SEE CONFIGURATION CHART. LOW VOLTAGE (FACTORY OR FIELD) 8

9 WIRING DIAGRAMS REMOTE THERMOSTAT OPERATION FUNCTION CONNECT CONNECT R TO: FUNCTION R TO: OFF OFF COOLING UNIT W/ELECTRIC G** PUMP W/AUXILIARY ELECTRIC G** ST STAGE ANTICIPATOR CURRENT:. 2ND STAGE ANTICIPATOR CURRENT:. * FOR A PUMP THERMOSTAT USED ON A STRAIGHT COOL UNIT POWER VE N T MOTOR MUFFIN WIRING DIAGRAM REV 0 POWER VENT COOL G, Y/W * COOL ST STAGE 2ND STAGE G, Y/W G,B,Y/W G, W2 ** GL- low speed GH- high speed 6 LINE COM H C F HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LINE COM X 24VAC~TRANSFORMER 2VA CLASS 2 ONLY 8 X E E2 RD LINE E GY2 RIBBED 2 WIRE GN ELECTRIC ER ER ER 2 YL0 GY22 RD COMP S R C BK8 LINE 2 5 VT2 OD /COMP CAP WH5 BK6 TERMINAL BLOCK BR4 RD7 RD4 BK7 BU4 WH7 E2 E E4 E5 E6 E7 E8 E9 E0 K4 K5 K6 CP4 BR4 BR4 CR P2 COMPRESSOR P5 MOTOR HIGH LOW REV K K2 K P P4 4 7 A WH8 X4 IDT BK GREEN ORANGE BU5 X2 6 9 B BK2 BU2 2 BU9 ON/OFF SWITCH BU0 REV 20 SOLENOID 9 P9 ICT RED P8 OCT BLUE SW2 P0 P P M ON / OFF MASTER SWITCH COM A COM B DS DS2 MS MS2 EH IN LS FD FD2 TF- TF+ C R GL W2 Y/W B GH AUXILIARY REMOTE THERMOSTATE IAT BLACK M2 7 4 FRON T DESK SWITCH NOTES : WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED (FOR 265V) AND GROUNDED. 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN. ON PUMP MODELS ONLY. 4 ON UNITS WITH FRONT DESK CONTROL SWITCH. 5 BK8 ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V. FOR 20V AND 5V, CONNECT POWER CORD TO LINE 2. 6 IF SUPPLY VOLTAGE IS 208V MOVE 240V LEAD TO 208V TAP ON TRANSFORMER. 265V AND 5V TRANSFORMER NOT SHOWN. 7 FOR REMOTE OPERATION, SEE CONFIGARATION CHART. 8 IF SUPPLY VOLTAGE IS 208V/20V USE THE 20V TAP ON TRANSFORMER. I F SUPPLY VOLTAGE IS 265V USE THE 265V TAP ON TRANSFORMER. 5V TRANSFORMER NOT SHOWN. 9FOR CONTINUOS OPERATION SEE CONFIGURATION CHART. CHASSIS USE COPPER CONDUCTORS ONLY GN WIRE LEGEND HIGH VOLTAGE (FACTORY) HIGH VOLTAGE (FACTORY OR FIELD) LOW VOLTAGE (FACTORY OR FIELD) CONTROL PANEL 9

10 COM COM WIRING DIAGRAMS PUMP W/AUXILIARY ELECTRIC FUNCTION CONNECT CONNECT R TO: FUNCTION R TO: OFF OFF REMOTE THERMOSTAT OPERATION COOLING UNIT W/ELECTRIC G G ST STAGE ANTICIPATOR CURRENT:. 2ND STAGE ANTICIPATOR CURRENT:. * FOR A PUMP THERMOSTAT USED ON A STRAIGHT COOL UNIT WIRING DIAGRAM REV 0 COOL G, Y/W COOL G, Y/W * ST STAGE 2ND STAGE G,B,Y/W G, W2 H C F YL0 RD OD /COMP CAP BR4 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. GY2 X 24VAC~TRANSFORMER 2VA CLASS 2 ONLY LINE X E E2 GY22 8 LINE E RD BR4 ELECTRIC ER RIBBED 2 WIRE G N BR4 ER ER 2 YL5 (CP) LINE 2 COMP S R C VT2 WH5 BK6 MOTOR YL (CP) RD7 E2 E E4 E5 E6 E7 E8 E9 E0 K4 K5 K6 CP4 CR BK8 P2 5 COMPRESSOR P5 HIGH LOW REV K K2 K P P4 5 A YL (CP) X4 IDT GREEN ORANGE OCT BLUE X B OR8 (CP) 6 WH 6 (CP) LINE 20 REV SOLENOID 9 P9 ICT RED P8 SW2 P0 P P M ON / OFF MASTER SWITCH COM A COM B DS DS2MSMS2EH IN LS FDFD2TF-TF+ C R GL W2 Y/W B GH AUXILIARY REMOTE THERMOSTATE IAT BLACK M2 7 4 FRONT DESK SWITCH NOTES WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED (FOR 265V) AND GROUNDED. 2 RIBBED WIRE MUST BE CONNECTED AS SHOWN. ON PUMP MODELS ONLY. 4 ON UNITS WITH FRONT DESK CONTROL SWITCH. 5 BK8 ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V. FOR 20V AND 5V, CONNECT POWER CORD TO LINE 2. 6 IF SUPPLY VOLTAGE IS 208V MOVE 240V LEAD TO 208V TAP ON TRANSFORMER. 265V AND 5V TRANSFORMER NOT SHOWN. 7 FOR REMOTE OPERATION, SEE CONFIGURATION CHART. 8 IF SUPPLY VOLTAGE IS 208V, MOVE 204V LEAD TO 208V TAP ON TRANSFORMER. 265V AND 5V TRANSFORMER NOT SHOWN. 9 FOR CONTINUOS OPERATION SEE CONFIGURATION CHART. USE COPPER CONDUCTORS ONLY GN CHASSIS CONTROL PANEL WIRE LEGEND HIGH VOLTAGE (FACTORY) HIGH VOLTAGE (FACTORY OR FIELD) LOW VOLTAGE (FACTORY OR FIELD) 0

11 THIS PAGE LEFT INTENTIONALLY BLANK

12 Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficiency. We have designed these units to significantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate. We use quality materials and components. Finally, every unit is run tested before it leaves the factory. That s why we know...there s No Better Quality. Visit our website at for information on: Products Warranties Customer Services Parts Contractor Programs and Training Financing Options is a trademark of Maytag Corporation and is used under license to Goodman Company, L.P. All rights reserved. Goodman Company, L.P North Loop West, Suite 400 Houston, TX Goodman Company, L.P. 2

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

REPAIR PARTS. PTC/PTH Packaged Terminal Air Conditioners and Heat Pumps P R PTC154B50BM P R PTC124B50AM.

REPAIR PARTS. PTC/PTH Packaged Terminal Air Conditioners and Heat Pumps P R PTC154B50BM P R PTC124B50AM. REPAIR PARTS PTC/PTH Packaged Terminal Air Conditioners and Heat Pumps PTC073B00AM PTC073B15AM PTC073B25AM PTC074B25AM PTC093B00AM PTC093B25AM PTC093B50AM PTC094B25AM PTC094B35BM PTC094B50AM PTC105B30AM

More information

REPAIR PARTS. PTH093G Package Terminal Heat Pump

REPAIR PARTS. PTH093G Package Terminal Heat Pump REPAIR PARTS PTH093G Package Terminal Heat Pump PTH093G15AXXXCA PTH093G15DXXXCA PTH093G25CQXXCA PTH093G25CXXXCA PTH093G25DRXXCA PTH093G25DXXXCA PTH093G25PXXXCA PTH093G25QRXXCA PTH093G25QXXXCA PTH093G25VWXXCA

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501

More information

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners using Installation Kit KIT-364-CM1 Contents Introduction... 2 Safety first... 2 Making a good crimp...

More information

REPAIR PARTS. PTH073G Series PTAC Heat Pump

REPAIR PARTS. PTH073G Series PTAC Heat Pump PTH073G Series PTAC Heat Pump PTH073G15AXXXAA PTH073G25AXXXAA PTH073G25CRXXAA PTH073G25CXXXAA PTH073G25DRXXAA PTH073G25DXXXAA PTH073G25PXXXAA PTH073G25QXXXAA PTH073G25RXXXAA PTH073G25VXXXAA PTH073G35AXXXAA

More information

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts This part list contains the service parts for the Eclipse 00, 00, and 800 systems. D series models began early 0 The models that are covered include: EH0 C & D EH0 C & D ECC00 ECC00 ECC800 Contents Head

More information

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS KAC-30 TECHNICAL EDUCATION 36 & 48 ISLAND AND WALL CANOPY RANGE HOODS JOB AID 4317332 FORWARD This Job Aid, KitchenAid 36 and 48 Island And Wall Canopy Range Hoods, (Part No. 4317332), provides the technician

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

Assembly Instructions

Assembly Instructions Assembly Instructions Part Number Description Model Approx. Assembly Time 99994-0903 Windshield Wiper Kit Mule SX 1 Hour WARNING Improper installation of this accessory could result in an accident causing

More information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more

More information

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2005 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CB29M & CB30M Elite Series Units MULTI POSITION BLOWER COILS 504,79M 09/05 Supersedes 04/05 Litho U.S.A. RETAIN THESE INSTRUCTIONS

More information

Parts Information. Commercial Microwave Oven

Parts Information. Commercial Microwave Oven Parts Information Commercial Microwave Oven Important notes: This is an uncontrolled document. There is no record of its distribution and no corrections will be provided. Models and Manufacturing numbers

More information

EasyStart Installation Instructions for Dometic Family RV A/Cs

EasyStart Installation Instructions for Dometic Family RV A/Cs EasyStart Installation Instructions for Dometic Family RV A/Cs DuoTherm Brisk Brisk II Penguin Penguin II Contents Introduction... 4 Safety first... 4 Making a good crimp... 4 Identifying Dometic AC Units...

More information

REPAIR PARTS. PTH153G Series Heat Pump

REPAIR PARTS. PTH153G Series Heat Pump REPAIR PARTS PTH153G Series Heat Pump PTH153G25AXXXAA PTH153G25CXXXAA PTH153G25RXXXAA PTH153G35AXXXAA PTH153G35CRXXAA PTH153G35CXXXAA PTH153G35DXXXAA PTH153G35QRXXAA PTH153G35QXXXAA PTH153G35RXXXAA PTH153G35VXXXAA

More information

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS NOTE TO INSTALLER The words SHALL and MUST indicate a requirement which is essential to satisfactory and safe product

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

Quarter Master Series 94 Actuator

Quarter Master Series 94 Actuator Quarter Master Series 94 Actuator Installation, Operation and Maintenance Manual Assembly Series 94 Manual Rev V 9/5/13 Page 1 of 12 Table of Contents Series 94 Electric Actuator Introduction... 3 Description...

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CRVMP-5 For Use with Bard 3 through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing Company Bryan, Ohio 43506

More information

Model 1693, 1694 Switching DC Power Supply

Model 1693, 1694 Switching DC Power Supply Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all

More information

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008 Replacement Parts List 700018500 Revision B 02/2012 Daikin McQuay Incremental Suite II, 2 Motor PDES 009-015 Design C (3) Last Manufactured: 2008 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODELS CRVMWH-3 For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

IMPORTANT ATTENTION INSTALLERS:

IMPORTANT ATTENTION INSTALLERS: Power Exhaust Kit for P7TQ, Q7TQ & R7TQ Series INSTALLATION INSTRUCTIONS IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION 0 F LOW AMBIENT ACCESSORY MODELS 2LA04703425, 3546 & 3658 (208, 230, 460 & 575 VOLT APPLICATIONS) Supersedes: 530.18-N5.6V (1091) 530.18-N5.6V (1193) FOR 15, 20 & 25 TON COOLING

More information

N-084M and N-069M-DV Series Heat Exchanger Replacement

N-084M and N-069M-DV Series Heat Exchanger Replacement N-084M and N-069M-DV Series Heat Exchanger Replacement Models Include: N-069M-DV, N-084M, N-084M-DV N-084M-ASME, N-084M-DV-ASME This instructional manual is only intended for use by a qualified service

More information

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL DESCRIPTION The CMH-7A is a field installable low ambient fan cycling control kit. The CMH-7A consists

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

Installation Instructions

Installation Instructions 010A00 011A00 014A00 SMALL ROOFTOP UNITS TWO POSITION OUTDOOR AIR DAMPER 2to15TONS (50/60 Hz) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE... 1 SAFETY CONSIDERATIONS...

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS (27/6/13) Contents 1. GENERAL DESCRIPTION... 2 2. RECEIPT AND PREPARATION... 2 3. INSTALLATION... 2 3.1. REMOVAL OF ACCESS PANEL... 2 3.2. FIXING A PLINTH...

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

Model 1672, 1673 Triple Output Power Supply

Model 1672, 1673 Triple Output Power Supply Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3) Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,

More information

SERVICE INSTRUCTIONS

SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic, LLC 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic, LLC 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 3313107.107 5 BUTTON THERMOSTAT

More information

INSTRUCTIONS INSTALLATION. Read these instructions carefully. These instructions MUST stay with this product.

INSTRUCTIONS INSTALLATION. Read these instructions carefully. These instructions MUST stay with this product. RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased INSTALLATION INSTRUCTIONS Roof Top Unit Used With 3105007.XXX or 3105935.XXX Air

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

Installation Instructions

Installation Instructions CRLOWAMB039A00 CRLOWAMB040A00 CRTRXKIT002A00 ACCESSORY MOTORMASTER I HEAD PRESSURE CONTROL KIT 12.5 TON HEAT PUMP Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PRODUCT USAGE... 2 SAFETY

More information

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400 IO-608 Houston, TN 77092 AHKD SERIES

More information

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY EXHAUST BRAKES C40019 1999-2003 FORD F250 / F350 7.3L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY Getting Started Thank you and congratulations on your purchase of a Pacbrake exhaust retarder.

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

* * APPLICABLE MODELS: 2014 > Mazda 3

* * APPLICABLE MODELS: 2014 > Mazda 3 PART NUMBER: 0000 8C L48 (DIO) / 0000 89 L84 (PIO) GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Rev. AAA *550-0700-000* APPLICABLE MODELS: 2014 > Mazda 3 REQUIRED COMPONENTS: ITEM QTY DESCRIPTION Usage

More information

Fan Coil Unit (FCU) Fan Motor Control

Fan Coil Unit (FCU) Fan Motor Control Fan Coil Unit (FCU) Fan Motor Control Fan Relay Board 2 (FRBii) Installation, Operation, and Maintenance The Fan Relay Board assembly (FRBii) provides electronic control for the fan motor and various connections

More information

* * APPLICABLE MODELS: 2014 > Mazda 6

* * APPLICABLE MODELS: 2014 > Mazda 6 PART NUMBER: 0000 8C H02(DIO) / 0000 89 H18(PIO) GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Rev. AAA *550-0694-000* APPLICABLE MODELS: 2014 > Mazda 6 REQUIRED COMPONENTS: ITEM QTY DESCRIPTION Usage

More information

Service & Maintenance

Service & Maintenance Service & Maintenance Amplifier Monitor LEDs & Tubes (Wall-Rock-PV) Translucent Panel (Wall-Rock-PV) Glass Panel (Rock-Star) Fans & Filter G2-1 External Peavey Amplifier) Amplifier Removal 1. Disconnect

More information

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide Rev. D 2018 nvent PH 763 422 2211 nvent.com NOTE: Refer to the instruction manual for all other installation

More information

Prodigy Eclipse 600, 800, 1000 Service Parts

Prodigy Eclipse 600, 800, 1000 Service Parts Prodigy Eclipse 600, 800, 000 Service Parts This part list contains the service parts for the Eclipse 600, 800 and 000 systems. The B series references changes to panels. The models that are covered include:

More information

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts list. MDTNs & MDTN0s have

More information

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference. AIR CLEANERS Model MX 6000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. MODEL MX 6000 SPECIFICATIONS Input Volts: 208-230/460 VAC, 60Hz, 3 Phase

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

TOYOTA TUNDRA TVIP V4 Preparation

TOYOTA TUNDRA TVIP V4 Preparation Preparation Part Number: PT398-00100 PT398-00100-AA Conflicts Do not install into vehicles without RKE system. Recommended Sequence of Application Item # Accessory 1 TVIP/RES Any TVIP or RES system 2 XM

More information

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS Instruction Manual Copyright, Athena Controls, Inc., 2006 Printed in USA CompuStep is a registered trademark of Athena Controls, Inc. SafeChange is a trademark

More information

Third Generation NITE Phoenix

Third Generation NITE Phoenix Technical Information and Diagnostic Guide for Third Generation NITE Phoenix Use this guide with unit serial number prefix beginning with BYC, CAI built after 2-10-2012 and CCA, CDJ, CIA units after 6/25/2012

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-3 For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps NOTE: CHCRV-3 Models must be installed with TCURB

More information

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS INSTALLATION INSTRUCTIONS For R7TQ/P7TQ/Q7TQ -090 (T) and -120 (T) Series Single Package Rooftop Units IMPORTANT ATTENTION INSTALLERS:

More information

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A Guide Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A Agilent Technologies, Inc. 2001 All Rights Reserved. Reproduction, adaptation, or translation without permission is prohibited, except

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

ELECRAFT KX3 Application Note

ELECRAFT KX3 Application Note ELECRAFT KX3 Application Note Installing the Speaker Grille Cloth Revision A, July 30, 2012 Copyright 2012, Elecraft, Inc., All Rights Reserved Background Some KX3 owners have reported issues with the

More information

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com.

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com. DASH AUDIO KIT P/N 2882030 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain these

More information

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A Installation Guide Heater Interface Cable for Mass Sensitive Detector Accessory G1590A Agilent Technologies, Inc. 2001 All Rights Reserved. Reproduction, adaptation, or translation without permission is

More information

AquaPure Ei TM Series Replacement Kits

AquaPure Ei TM Series Replacement Kits AquaPure Ei TM Series Replacement Kits for Models APURE35/35C WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the

More information

Triple Output Power Supply

Triple Output Power Supply Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions

More information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information

SECTION 5 PARTS LISTS & EXPLODED VIEWS

SECTION 5 PARTS LISTS & EXPLODED VIEWS Model 506 (UC Ice Maker) Parts Lists & Exploded Views SECTION 5 PARTS LISTS & EXPLODED VIEWS 5-1 #3752200 - Revision B - May, 2006 Parts Lists & Exploded Views Model 506 (UC Ice Maker) 506 CABINET, LINER

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K DUSA Pharmaceuticals, Inc. Table of Contents Go to Chart # Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K BLU-U Features: 10K BLU-U Features 10K BLU-U Symptom Fans Running, Timer

More information

Document # 1556 Created 8/16/02 TOYOTA TUNDRA GENTEX COMP/TEMP MIRROR Section I Installation Preparation Part Number:

Document # 1556 Created 8/16/02 TOYOTA TUNDRA GENTEX COMP/TEMP MIRROR Section I Installation Preparation Part Number: Document # 1556 Created 8/16/02 TOYOTA TUNDRA 2003- GENTEX COMP/TEMP MIRROR Section I Installation Preparation Part Number: 00016-34391 Section I Installation Preparation Kit Contents 1 1 Full Mirror Assembly

More information

ARTICLE BEGINNING SERVICE PRECAUTIONS

ARTICLE BEGINNING SERVICE PRECAUTIONS Page 1 of 96 ARTICLE BEGINNING SERVICE PRECAUTIONS WARNING: WARNING: CAUTION: When performing any inspection or service procedure on this vehicle, ensure following service precautions are followed to prevent

More information

NIDAC EMC Communicating Motor

NIDAC EMC Communicating Motor NIDAC EMC Communicating Motor IFC 12 V Variable Speed Connection Variable Speed Connection 12 V = + 12 Volt DC RX = Motor to Furnace Control Data TX = Furnace to Motor Control Data GND = 12 Volt DC Ground

More information

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724) Installation, Operation, and Maintenance Manual CEMLINE CORPORATION Electronic Controls for Water Heaters with RWD45U Controller CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724)

More information

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. 1 10/2014 REV 7 !!Attention!! Before performing diagnostics: Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. Check for Fault Codes using the

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

Installation Instructions

Installation Instructions CALOWAMB001A00 - CALOWAMB011A00 CALOWAMB030A00 - CALOWAMB036A00 SPLIT SYSTEMS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 6to12.5TONS Installation Instructions IMPORTANT: Read these instructions

More information

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INTRODUCTION: CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INSTALLATION & OPERATING INSTRUCTIONS CONGRATULATIONS on your choice of a Remote Keyless Entry System by Crimestopper Security Products Inc.

More information

Prodigy Eclipse 600, 800, 1000 Service Parts

Prodigy Eclipse 600, 800, 1000 Service Parts Prodigy Eclipse 600, 00, 000 Service Parts This part list contains the service parts for the Eclipse 600, 00 and 000 systems. The B series references changes to panels. The models that are covered include:

More information

Instruction Book for. ContouR ElECtRol

Instruction Book for. ContouR ElECtRol Instruction Book for ContouR ElECtRol IMPORTANT SAFETY INSTRUCTIONS When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand

More information

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12' INSTRUCTION BOOK FOR Cosmopolitan Electrol For Sizes To 9' x 12' Important Safety Instructions When using your video equipment, basic safety precautions should always be followed, including the following:

More information

* * APPLICABLE MODELS: 2017 > CX-5

* * APPLICABLE MODELS: 2017 > CX-5 PART NUMBER: 0000 8C R06(DIO) / 0000 89 R28(PIO) GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Rev. AAA *550-0681-000* APPLICABLE MODELS: 2017 > CX-5 REQUIRED COMPONENTS: ITEM QTY DESCRIPTION Usage Chart

More information

Recommended Tools: Phillips Screwdriver, Flat Blade Screwdriver, 13mm and 10mm Wrench, 5/16 nut driver,

Recommended Tools: Phillips Screwdriver, Flat Blade Screwdriver, 13mm and 10mm Wrench, 5/16 nut driver, UPS-ST-120 UPSPro Outdoor UPS System Wireless Base Stations and Client Devices Surveillance Cameras Mission Critical Backup Power Remote Sensors Congratulations! on your purchase of the UPSPro Outdoor

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

REC-11+ REMOTE RECEIVER UNIT

REC-11+ REMOTE RECEIVER UNIT Resetting The Programmable Features The installer may quickly and easily return all 17 programmable features back to the factory settings. Changing individual features were explained in detail in the previous

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

An ISO 9001:2008 Registered Company

An ISO 9001:2008 Registered Company An ISO 9001:2008 Registered Company CVC501-A HVAC & Fast Idle CAN Vehicle Controller CVC502-A HVAC Control without Fast Idle 2011-2016 Ford F250-F550 (CVC501/502-A) 2017 Ford F-250-F550 (B-CVC501/502-A)

More information

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH INSTALLATION MANUAL MODEL #100947, 100950 50 AMP MODEL #100949, 100952 100 AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit

More information

XS400 Load Bank. Read all instructions before using the load bank. Contents

XS400 Load Bank. Read all instructions before using the load bank. Contents Read all instructions before using the load bank Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 3) Receiving... 4 4) Safety... 5 a) Grounding cam... 6 b) Power connections... 6

More information