1 Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Electrical Requirements: 24 VAC, 3.2 Amp 13VAC, 2 Amp Attention These instructions apply to Midmark cabinetry. For other cabinetry, additional steps may be required. Refer to 12:00 Procenter Delivery Mounting Kit Installation Instructions [ ] to confirm necessary steps have been completed before proceeding with this installation. Components: none Special Tools: none Cabinet Mount Arm (Pivoting) Cabinet Mount Arm (Pull Out) Leave push retainers on screws for install. Align mounting holes in leveling plate and cabinet mount arm plate with mounting holes in cabinet. Secure with screws but do not tighten. Locate three holes toward front of cabinet for proper rotation when installing. DA2230i Rev. S (11/3/16)
2 Mounting Control Panel Align top and bottom slides on delivery panel with slides on cabinet and carefully move into position. Step 3: Route foot control tubing through hole in cabinet base. Secure with screws. Position bearing race at end of each slide that is attached to cabinet. DA2372i : Slides maybe mounted on RH side of cabinet. 2
3 Regulator Installation Insert regulator into compression fitting of shut-off valve and tighten compression fitting. : Delivery and Assistant s Unit Tubing Connections are located in cabinet base. WATER REGULATOR Regulator Compression Fitting Shutoff Valve AIR REGULATOR Compression Fitting Regulator Shutoff Valve Tubing Connections (J-Box) Foot Control (Procenter Delivery Unit Only) The diagram shows all possible connections for the delivery system. Foot Control used for Delivery Unit (Only) Vacuum Connections used for Assistant s Unit (Only). 80 PSI 1/4 Grey (Ribbed) Rib 1/4 Grey (Plain) Master Pilot Shut-Off Transformer Air Pressure (Optional) Grey (Above 1/4 Ribbed) Grey Input INACTIVE - no air from master switch Air Supply ( PSI) Master Pilot Shut-Off 1/4 Clear Orange Green or 1/4 (Filtered / Regulated Air - [80 PSI]) (Filtered / Regulated Air - [80 PSI]) Purple (Unfiltered / Unregulated Air - [ PSI]) To Handpiece Coolant Air To Pilot Air for Coolant To Handpiece Drive Air Air To Master ON/OFF Switch Air To Syringe Air To Bottle Unfiltered Output ( PSI]) Air From Master ON/OFF Switch ACTIVE - air coming from master switch Filtered Output Supply (30-50 PSI) Master Pilot Shut-Off 30 PSI 5/8 Vacuum Vacuum Supply Tube (Assistant s Unit Only) Syringe Tubing Ribbed Side Instrument from Control Panel / Bottle Assembly City to/ Selector Valve 3
4 Work Surface / Unit Mount Arm Installation & Adjustment Cabinet Mount (Pivoting) Cabinet Mount (Pull Out) Maximum Weight Limitation 40 lbs. (18 kg) Align desired mounting holes in work surface, leveling plate, and mount arm. Secure with screws. Work Surface Work Surface Plate On the Pivoting Unit, Insert Unit Mount Arm into Cabinet Mount Arm. Mount Arm Cabinet Mount Arm Plate Mounting Step 4: Pivot Points & Set On the Pivoting Unit, Adjust drag by loosening or tightening set screws at pivot points. Step 3: DA2233-1i Work Surface: Loosen mounting screws. Adjust leveling screws. Retighten mounting screws. Mounting 4
5 Routing / Securing Tubing Cabinet Mount (Pivoting) Adhesive backed mounting platforms are provided for units without control panel. Apply mounting platform to inside of cabinet and secure vacuum with wire tie: then go to step 2. Cabinet Mount (Pull Out) For ease of installation it may be helpful to extend the work surface by pulling it outward. Equipment Alert When securing tubing, allow sufficient slack in tubing for movement of control panel / mounting arm. Failure to do so could result in tubing becoming disconnected or damage. Bundle tubing from Doctor s / Assistant s Delivery Units and install in brackets then secure with screws. Bundle tubing from control panel and install bracket; DA2394i then secure bracket with screws. Loosen screws on both side of mounting brackets and remove bracket.. 5
6 Tray / Tub Assembly Installation for Pull Out Unit The Work Surface assembly can accommodate accessories (9 x 13 Tray Assembly or a Tub Support). The assembly can be installed for either right or left hand operation. Step 4: Install the Tray Assembly or Tub Support. Position tray clamp assembly onto work surface and tighten thumb screw. Step 3: Insert the flange bearing into tray clamp assembly. Base used with Corian tops If necessary, replace base of tray clamp assembly by removing screws, thumb screw, and clamp plate, place new base in place and re-assemble. : Used on Laminate and Quartz work surfaces. Base used with Laminate and Quartz tops. DA2395i 6
7 Chair Control Touch Pad Connections (Optional) LH Mount (Shown) Open Equipment Base mounts to Center Console with 3 screws. On Side Delivery Units, the shipping leg must be removed first. The following procedure applies only when using this delivery system with a Midmark Dental Chair. If not using a Midmark Dental Chair, or if the delivery system does not include the optional Chair Position Touch Pad, this procedure is not necessary. Connect 15 ft. wire harness to touch pad wire harness. Route wire harness out through hole in front of base and install bushing. 15 ft. Extension Step 4: Connect 12 in. wire harness extension to J2 position on Chair PC Board. 12 in. Extension Step 5: Connect 12 in. wire extension to wiring harness. Hydraulic Cover Step 3: Remove Hydraulic Cover and route wire harness behind base cover of chair. J2 J10 Chair PC Board J11 J13 Step 6: Install Hydraulic Cover. DA2371i 7
8 Tubing Connections (Vacuum Instrument Arm Assembly) Saliva Ejector Closed Open Open Closed Air N.C. Limit Switch COM NC High Volume Evacuator (HVE) 30 PSI Quick Disconnect Master On/Off Valve 1/4" " Double Pinch Valve " Air 80 PSI Air Quick Disconnect N.C. Limit Switch NC Assistant's Unit w/ Optional Switches COM F E D C B A 24 V 24 V 0 V 0 V Orange Green White Black To Junction Box Solids Collector Capped Vacuum To Umbilical Vacuum Supply Bottle Cap City Syringe Tubing Orange Umbilical Bottle In line Regulator Orange N.C. Limit Switch NC COM Selector Valve City Push (Optional) FlushValve (N.C.) 2-Way Manual Momentary 8
Flex Work Station Delivery Units Installation Guide
Flex Work Station Delivery Units Installation Guide Special Tools Level 1/4" Deep Well Socket 3/8" Masonary Bit 9/32" Wood Bit Hammer Drill Remove any packaging from the skid and the floor or wall mount
More informationWall / Casework Mounted Delivery Systems (Procenter)
20 20 0 0 40 40 2 3 0 4 60 60 5 6 7 80 80 00 00 2 3 4 Wall / Casework Mounted Delivery Systems (Procenter) Common Components...004-0859-99 2:00 / FTC Delivery Systems Side Delivery Systems... 004-0886-99
More informationTubing / Wiring Diagrams: Procenter Delivery Systems (12:00 / FTC Mounted)
Tubing / Wiring Diagrams: Procenter Delivery Systems (12:00 / FTC Mounted) Attention This document contains wiring and/or tubing diagrams for the models listed in the table below. Locate the desired diagram
More informationProcenter Delivery, Console Mounted on an Elevance Chair Installation Guide
Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is
More informationSide Delivery Unit Installation
Side Delivery Unit Installation CONTENTS Mounting Location... 1 Minimum Cabinet Size Requirements... 1 Mounting Requirements... 1 Regulator Installation... 2 Cabinet Mount Bracket Installation... 2 Wall
More informationAsepsis 21 Delivery Unit
INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.
More informationTubing / Wiring Diagrams: Elevance Delivery Systems (Console / LR Mtd: Elevance Chair)
Tubing / Wiring Diagrams: Elevance Delivery Systems (Console / LR Mtd: Elevance Chair) Attention This document contains wiring and/or tubing diagrams for the models listed in the table below. Click on
More informationINSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580
R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH
More informationTroubleshooting Guide: Elevance Delivery Systems
Troubleshooting Guide: Elevance Delivery Systems FOR USE BY MIDMARK TRAINED TECHNICIANS Contents Description / Links Troubleshooting Charts ICM Screens Assistant s Unit Instruments (Elevance & European)
More informationforest dental australia affordable excellence + designer friendly
Component Catalogue 204 table of contents section pages light service items............................................ 2-3 handpiece controls..............................................4 arm systems................................................
More informationTubing / Wiring Diagrams: Procenter Delivery Systems (Wall / Cabinet Mounted)
1 2 4 3 Tubing / Wiring Diagrams: Procenter Delivery Systems (Wall / abinet Mounted) Attention This document contains wiring and/or tubing diagrams for the models listed in the table below. lick on the
More informationaxcs Chair Mounted Unit Installation, Operation and Care Manual
axcs Chair Mounted Unit Installation, Operation and Care Manual DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 Table of Contents Section I Introduction Introduction... 2-3 Specifications...
More informationEvogue Dental Unit IMPORTANT
Evogue Dental Unit INSTALLATION INSTRUCTIONS IMPORTANT This manual provides installation instructions for the Evogue unit. The instructions contained in this booklet should be thoroughly read and understood
More informationLoose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:
VetPro 5000 Wall / Cabinet Mount Installation warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. Applies to Models: 8001-001 8001-002 8001-005 8001-006 Loose Components
More informationRadius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)
INSTALLATION INSTRUCTIONS Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs) You Will Need: Hex key set Level Large flat head screwdriver Pliers 1/2" and 9/16" wrench Cutters Before Beginning
More informationSimplicity Magellan Unit
Simplicity Magellan Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 2 Classifications... 2-3 Dimensions... 3 Basic
More informationProcenter Delivery Systems
2 4 2 4 2 4 Procenter Delivery Systems Cuspidor (Procenter)...004-0847-99 Chair Mounted Delivery Systems Wall / Casework Mtd. Delivery Systems....004-0858-99 Control Knob Labels 004-845-99 [Revised: 2/6/208
More informationAsepsis 21 Delivery Systems
Asepsis Delivery Systems Chair Mounted Floor Mounted Side / Rear Cart Serial Number Prefixes: PJ, PK, PL, PM, UA, UC, UK, UW & V Service and Parts Manual NOTE: Sterling Grey painted parts are no longer
More informationaxcs Magellan CMU Installation, Operation and Care Manual
axcs Magellan CMU 123456789012 123456789012 123456789012 123456789012 Installation, Operation and Care Manual Table of Contents Section I Introduction Introduction... 2 Specifications... 3 Basic Components...
More informationMounted Instrument Head
INSTALLATION INSTRUCTIONS for the Asepsis 21 Cabinet TM Mounted Instrument Head SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 4. WATER SUPPLY REQUIREMENTS... 1 5. AIR SUPPLY REQUIREMENTS... 1
More informationJunction Boxes. Common Components Air / Water Control Valves. Contoured Junction Box. Small Junction Box. Elevance Junction Box
7 8 7 8 8 Junction Boxes Common Components...-89-99 Air / Water Control Valves Contoured Junction Box DAi Small Junction Box Elevance Junction Box TP Rev. A Square Junction Box (optional) Camera Junction
More informationDECADE 1021 SOLO CHAIR
Owner's Guide DECADE 1021 SOLO CHAIR 85-2626-00 Warranty A-dec warrants its products against defects in material or workmanship for one year from time of delivery (except for handpieces which have a warranty
More informationDECADE 1021 VAC BACK CHAIR
Owner's Guide DECADE 1021 VAC BACK CHAIR 85-2625-00 Warranty A-dec warrants its products against defects in material or workmanship for one year from time of delivery (except for handpieces which have
More informationFeatures: Positive on/ off control Brass construction Nickel plated Port size Panel mount with nuts, 15/ black gray.
toggle valve, on/off Positive on/ off control Panel mount with nuts, 15/32-32 2-way without exhaust: 1100-402-6-BLK 1100-402-6-G gray 3-way with exhaust: 1100-400-6-BLK 1100-400-6-G gray toggle only: $19.00
More informationProduct Name Chair Conversion Kit (to Console Delivery Unit) Installation [Kit # xx]
Elevance Product Name Chair Conversion Kit (to Console Delivery Installation Unit) Installation [Kit #002-1965-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance Console
More informationInstallation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach
Installation Operation Maintenance Troubleshooting Version 1, Oct/09 1655 Palm Beach Congratulations! All of us at Summit Dental Systems want you to know that your 1655 Palm Beach Cuspidor has been built
More informationCASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD
R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH
More informationMirage Dental Delivery Unit MSP3500/3550 Installation Instructions
! Mirage Dental Delivery Unit MSP3500/3550 Installation Instructions TPC 851 S. Lawson St. City Of Industry, CA 91748 P626-810-4337 Fax 626-810-4245 REV. 1-1-13 Table on Contents: Page GENERAL INFORMATION
More informationSimplicity Hygiene Unit
Simplicity Hygiene Unit (Magellan Style) Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 3 Classifications... 3 Dimensions...
More information1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17
Installation Operation Maintenance Troubleshooting Version Dec/17 1416 Cabinet Unit Page 1 of 16 Table of Contents Important Information... 3 Weight & Dimensions... 4 Operator s Instructions... 5 Flow
More informationA-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE
A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... 2 Install the Rigid Arm....... 3 Connect the Electrical Wires and Data
More informationChair Mounted Unit. Installation, Operation and Care Manual. DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507
axcs Basic-Duo Chair Mounted Unit Installation, Operation and Care Manual DentalEZ Group 2500 Highway 31 South Bay Minette, AL 36507 Table of Contents Section I Introduction Introduction... 2 Specifications...3
More informationPerformer Delivery System (Performer I Chair - International, and Performer III Chair)
Performer elivery System (Performer I hair - International, and Performer III hair) I NSTLLTION UI Introduction This document contains installation instructions for the Performer elivery System (Performer
More informationSimplicity Chair Mounted Unit
Simplicity Chair Mounted Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 3 Classifications... 3 Dimensions...
More informationInstallation Instructions: Swing Mounted Units BDS-2575
Installation Instructions: Swing Mounted Units BDS-2575 X-Calibur Units Installation Instructions for BDS-2575 X-Calibur Dental Units 8-23-10 BDS Swing Mounted Units Installation Time: Approximately 2
More informationInstallation Instructions: Side Delivery Units BDS-2555
Installation Instructions: Side Delivery Units BDS-2555 X-Calibur Units Installation Instructions for BDS-2555 X-Calibur Dental Units 7-18-06 BDS Side-Delivery Unit Installation Time: Approximately 1
More informationNextGen Cart Delivery Unit
NextGen Cart Delivery Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 2 Classifications... 2 Dimensions... 3 Features
More informationA-dec O Clock Delivery System
Installation Guide A-dec 500 12 O Clock Delivery System Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation Before starting the installation: Check with local building and code authorities
More informationTable of Contents. Section I Introduction. Section V Operation. Section II Pre-installation. Section VI Care. Section III Installation
Table of Contents Section I Introduction Classifications... 2 Specifications... 2 Dimensions... 3 Unit Features... 4 Packaging... 5 Section II Pre-installation Utility Service Compartment... 6 Plumbing
More informationMidmark Light Install: L/R mounted on Ultra Chair
Midmark Install: L/R mounted on Ultra Chair warning Equipment is not suitable for use in the presence of a flammable anesthetic mixture. Applies to Models: 153914 (-002) 153915 (-002) Language of origin:
More informationCavitron G139 Scaler 360 Replacement Kit Installation Guide (for Procenter 12:00 Delivery Units)
Cavitron G139 Scaler 360 Replacement Kit Installation Guide (for Procenter 12:00 Delivery Units) Note Use this kit to REPLACE an existing Handpiece with the Cavitron G139 Scaler 360 on a Procenter 12:00
More informationA-dec 542 Side Delivery System I NSTALLATION GUIDE
-dec 542 Side Delivery System I NSTLLTION GUIDE This document contains installation instructions for the -dec 542 side delivery system. NOTE Depending on your equipment configuration, some steps in the
More informationA-dec 541 Delivery System and 545 Assistant s Instrumentation
Installation Guide A-dec 541 Delivery System and 545 Assistant s Instrumentation Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation The instructions are the same for installing both the
More informationService Guide A-DEC SIMULATORS. Mobile (4810) and Stationary (4820)
Service Guide A-DEC SIMULATORS Mobile (4810) and Stationary (4820) A-DEC M OBILE AND STATIONARY SIMULATORS 4810 AND 4820 S ERVICE GUIDE Copyright 2015 A-dec Inc. All rights reserved. 2601 Crestview Drive,
More informationLuxury.Quality.Comfort
Luxury.Quality.Comfort Simple. Strong. Stylish. Zakton new dental operatories combine simplicity, style and strong construction at an affordable price: * Z2-2017-RL: with Right/Left versatility, Premium
More informationProduct Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]
Elevance Product Name Chair Conversion Kit (to LR Delivery Unit) Installation Installation [Kit #002-1966-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance LR mounted
More informationInstructions for Use. A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s
Instructions for Use A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s 85.2643.00 Copyright 2016 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material,
More informationQuolis 5000 Operatory Ensemble
7950 Cherry Ave. Suite 103, Fontana, CA 92336 866.274.8351 f 951.848.9700 www.ashteldental.com Quolis 5000 Operatory Ensemble BRH00034 REV 100107 FinalBelmontCatalogDesign.indd 1 9/2/07 4:25:44 PM Q u
More informationCascade Master Series
Overview The Cascade Master Series option consists of five components, which control standard chair and delivery system functions. These components include: master touchpad, master 17-watt power supply,
More informationMonitor Support Arms. Service and Parts Manual Part / Kit Numbers:
Monitor Support Arms Part / Kit Numbers: 153698 153699 153705 002-1836-00 153762 153763 153798 153823 153824 Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY 004-0806-00 (7/30/15) Table
More informationMidmark Dental Lightheads
Midmark Dental Lightheads Halogen Lighthead (short neck) LED Lightheads Halogen Lighthead (long neck) Index: Halogen / LED 004-0815-00 [Revised: 11/5/12] Pictorial Index: Halogen Lightheads (short neck)
More informationGalaxy Wall / Cabinet Mounted Unit
Galaxy Wall / Cabinet Mounted Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Introduction... 2 Basic Components... 2 Classification...
More informationCascade 3072 Delivery System INSTALLATION GUIDE
Cascade 3072 Delivery System INSTALLATION GUIDE Getting Started Figure 1. Cascade 3072 Delivery System See the section below that applies to your unit. the Wall............. 1 Preference II 5512 Cabinet......................................
More informationA-dec 336 Delivery System on an A-dec 411 or 511 Dental Chair INSTALLATION GUIDE
A-dec 6 Delivery System on an A-dec 4 or 5 Dental Chair INSTALLATION GUIDE Before You Install the 6 Delivery System Install the Rigid Arm A-dec 4 Dental Chair: Follow the instructions for installing the
More informationSpring Bearing Rocker Replacement Installation [Kit # ] for Elevance Continental-Style Delivery Unit
Spring Bearing Rocker Replacement Installation [Kit # 002-2076-00] for Elevance Continental-Style Delivery Unit Note Use this kit to replace one or more Spring Bearing Rockers in an Elevance Continental-Style
More informationAmdent Scaler System ( ) Installation Guide
Amdent Scaler System (153631-001) Installation Guide CONTENTS Unpacking... 1 Standard Handpiece Tubing Removal... 1 Scaler Components Installation... 2 Scaler Tubing Connection... 3 Scaler Electrical Connections...
More informationDelivery Units & Lights
Section Section Delivery Units & Lights 866-DTE-INFO 69 www.dentalez.com 866-DTE-INFO www.dentalez.com 69 Delivery Units Delivery Units/Lights Creating a new level of efficiency, DentalEZ Delivery Units
More information491 Harness Installation Kit
491 Harness Kit 002-0759-00 Kit Components: Qty Harness Assy... 1 Wire Clip... 2 Wire Tie (7 1/2 )... 5 Wire Tie (7 1/4 )... 4 Instruction... 1 Remove Back Cover Warning Disconnect Power before removing
More informationProcenter Cuspidor. Common Components Console Mounted Cuspidor. for Ultra Chairs for Elevance Chairs. for European Assistant s Unit
Procenter Cuspidor Common Components...004-0859-99 Console Mounted Cuspidor for Ultra Chairs for Elevance Chairs for European Assistant s Unit 004-0847-99 [Revised: 2/4/207] Console Mounted Cuspidors Common
More informationInstallation Instructions for Swing Mount System
Table of Contents Page Unit Installation Notes 2 Swing Arm Assembly to Chair Installation 3 Delivery System Installation 4 Utility Center Installation 5 Page 1 of 5 Unit Installation Notes Before You Begin
More informationMirage Dental Delivery Unit Model 2000 / 2015 Installation Instructions
Mirage Dental Delivery Unit Model 2000 / 2015 Installation Instructions 851 S. Lawson St. City Of Industry, CA 91748 P626-810-4337 Fax 626-810-4245 REV. 1-1-13 Each Mirage delivery unit will contain the
More informationInstructions for Use. Cascade 2615 Cart
Instructions for Use Cascade 2615 Cart 85.0664.00 Copyright 2016 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the
More informationAssistant s Instrumentation T
Instructions for Use Assistant s Instrumentation 85.2610.00 T Copyright 2015 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited
More informationINTRODUCTION TO SERVICING THE A-dec Handpiece Control Blocks
INTRODUCTION TO SERVICING THE A-dec Handpiece Control Blocks August, 2017 Presented by Mark Micucci Product Engineer Replacement Parts Industries, Inc. Course Overview The Handpiece Control Block (located
More informationSpirit 2000 Series Installation Instructions
Model: SCT20 Catalog: 2100, 2105 PMU Mounted Catalog 2222, 2322 Cabinet Mounted Model: SDW-D Catalog: 2600 Wall Mounted Model: SDC-D Catalog: 2610 Cabinet Mounted Spirit 2000 Series Installation Instructions
More informationSupplement to the January 1, 2017 Price Book
Sulement to the January 1, 2017 Price Book Effective Aril 1, 2017 PRICE CHANGES: BDS0050 ASSISTANT INTSTRUMENT VAC PAC REVISED WARRANTY SUPPLEMENT PRICES & WARRANTY EFFECTIVE Aril 1, 2017 Suersedes All
More informationForest Dental Equipment Catalog. DentalEZ Integrated Solutions
Forest Dental Equipment Catalog DentalEZ Integrated Solutions Got Color? We Do. 9 POWDER COAT PAINT COLORS: Forest Grey, Shadow, White, Pewter, Midnight, Copper, Charcoal, Bronze, Arctic Silver 17 ULTRALEATHER
More informationMicroprocessor Controlled Dental Vacuum System Installation Manual
Microprocessor Control System Installation Manual Microprocessor Controlled Dental Vacuum System Installation Manual Effective Date: 05-Aug-05 Review this entire booklet before starting any mechanical
More informationOwner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT
Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT 85.2641.00 ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May
More informationEquipment Order Guide
Equipment Order Guide Effective April 1, 2016 DCI EDGE Equipment Order Guide ORDERING INFORMATION When ordering, please include the following information: DCI requires Doctor, Clinic Name and Address before
More informationInstallation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520
Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520 X-Calibur BDS Delivery Systems Installation Instructions for BDS-2500, 2505, 2510, 2515, 2520
More informationAdvanced Technology in Dentistry
Advanced Technology in Dentistry Aseptico s full-featured Transport MDS Electric Military Field Dental System is a result of years of analysis, design, engineering and testing. The Transport MDS provides
More informationA-dec 200 Service Guide Contents
A-dec 200 Service Guide 1 A-dec 200 Service Guide Contents Overview... 3 Get Support... 3 International Customer Service... 3 Other Sources of Information... 3 Electronic Documentation... 3 A-dec 200 System
More informationSection. Vacuums. 866-DTE-INFO 147
Section Vacuums 866-DTE-INFO www.dentalez.com 147 Vacuums How to size your RAMVAC Dental Vacuum. Method One: The Precise Equipment Selection Method, pick a custom system. Works for any application. Select
More informationINSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS
INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS Customer Service and Technical Support: 8:00 AM to 5:00 PM central (M-Th) 8:00 AM to 4:30 PM central (Fri) Phone: 800-257-7407
More informationTrack Light with Monitor Installation Guide
Track Light with Monitor Installation Guide This installation requires at least two service technicians. Track with light and monitor weight (max.) is 157 Lbs. (71 kgs). Applies to Models: 1531017 (-000
More informationKnee Crutches / Cladding [9A410 / 9A411 / 9A412 / 9A413]
Knee Crutches / Cladding [9A40 / 9A4 / 9A42 / 9A43] Intended Use: To support patient s knees / legs during examinations. Requirements: 604 / 622 / 623 models require a special cladding kit to accommodate
More informationCOMMERCIAL ELECTRIC DRYER
COMMERCIAL ELECTRIC DRYER MODEL MLE24PRAZW1 05 12 Litho in U.S.A. (CMS)(bay) c 2012 WHIRLPOOL CORPORATION Part No. Rev. A LOWER CABINET AND FRONT PANEL PARTS 2 LOWER CABINET AND FRONT PANEL PARTS 1 Literature
More informationOwner s Guide PERFORMER III
Owner s Guide PERFORMER III 85.2638.00 R ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May June July August September October November
More informationSX4000. Dental Treatment Unit
SX4000 Dental Treatment Unit SX4000 2 Optimum dental workflow Reliability, durability and timeless design are the key elements of the SX4000 dental treatment unit from Siamdent. The SX4000 represents the
More informationMidmark Track Light Installation
Midmark Track Light Installation [Full size ceiling template is available: 003-1287-00] Applies to Models: 153910 (-002) 153656 (-001) Language of origin: English Physical Requirements warning Equipment
More informationInstallation Instructions PowerBoard Automatic Retracting Running Board
Installation Instructions PowerBoard Automatic Retracting Running Board Vehicle Application Ford Super Duty F-250/350/450 Crew Cab 2008 and newer Part Number: 75134-15 www.bestop.com - We re here to help!
More informationOperatory Ensenble. Configurations. Operatory Ensenble
Operatory Ensenble Configurations With Vac Pac Without Vac Pac or Cuspidor With cuspidor & assistant instruments With cuspidor Delivery system with swing-mount light Operatory Ensenble QDU-5870 QDU-5670
More informationMidmark Cabinet / Wall Light Installation
Midmark Cabinet / Wall Light Installation [Full size template is available: 003-1289-00] warning Equipment is not suitable for use in the presence of a flammable anesthetic mixture. Equipment Alert Before
More informationPatient Chairs Operatories Delivery Units Lighting Seating Enhancements
Patient Chairs Operatories Delivery Units Lighting Seating Enhancements C L A S S I C O P E R A T O R I E S Backed by over 90 years of healthcare manufacturing experience, Midmark provides a full line
More informationOUR MISSION TABLE OF CONTENTS
2019 OUR VISION A Perferred Company To create a quality environment where people can work together to provide simple, creative solutions for the betterment of dentistry. OUR MISSION Continuous Improvement
More informationMulti Pro WM Turf Sprayer
Form No. 3420-208 Rev A Multi Pro WM Turf Sprayer Model No. 41240 Serial No. 401321101 and Up Register at www.toro.com. Original Instructions (EN) *3420-208* A Ordering Replacement Parts To order replacement
More information-1- White Tape. Figure 1
Passenger, Hand warmer, 550 IQ KIT P/N 2878201 Application 550 IQ Touring Before you begin, read these instructions twice and check to be sure all parts and tools are accounted for. Please retain these
More informationGo Digital! Advanced Conscious Sedation Systems. 2 New Products! New! New! Digital Precision and Safety. Clearing Your Work Space.
Advanced Conscious Sedation Systems YEARS OF INNOVATION Go Digital! Flowmeters: Digital Percentage Conventional Digital Precision and Safety Systems: Central Portable Enclosed Portable Cabinet-Mounted
More informationMaster Slave Converter [ VAC & VAC]
Master Slave Converter [002-1590-00-115 VAC & 002-1590-01 230 VAC] Contents: Installation...1 Wire Diagram...4 Exploded View...6 Intended Use: To provide simultaneous operation of up to five Midmark compressors
More informationI-BFV.KIT Butterfly Valve Gear Operator Replacement
SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before
More informationM9/D (-020 thru -022) M11/D (-020 thru -022)
M/D (-020 thru -022) Item Description / Page Includes A Main Enclosure top cover / display panel assembly, leveling feet, hinge cover panels (side / back / base) B Reservoir / Drain Tube condensing coil,
More informationVeterinary Synthesis TM Table Parts List
Veterinary Synthesis TM Table Parts List General Information Cleaning & Maintenance Weights & Dimensions a) Wet Table (Standard Depth Tub) b) Wet Table (Shallow Depth Tub) c) Dry Table Door Adjustment
More informationDynamic Group: Innovator And Leader
Dynamic Group: Innovator And Leader Dynamic is the first corporation which came up with the concept of silent oil free air compressor. Dynamic was founded in 2004, which combining R&D, manufacturing and
More informationParts Manual / ZEKH / ZEKH / ZEKH52240
Parts Manual 99999 / ZEKH00 99999 / ZEKH0 999970 / ZEKH50 MODEL NUMBER SERIAL NUMBER DATE PURCHASED DEALER ADDRESS NOTES: 00 Yazoo/Kees Power Equipment All rights reserved. Beatrice, NE. Printed in U.S.A.
More informationService Guide: Power Supply Model
Service Guide: Power Supply Model 153808 The Power Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents:
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publication No. After 13 TRX420 All MII 15067 KIT (except 14 TRX420FA/FPA) Issue Date P/N 08T71-HR3-A20 After 13 TRX500 All (except 14 TRX500FA/FPA) September
More informationNEXUS. Introduction SENSOR MODULE &
2650-1056 INSTALLA AT TION INSTRUCTIONS NEXUS SENSOR MODULE & REMOTE ASSEMBLY IMPORTANT WEAR SAFETY GLASSES 60 80 40 100 FUEL 20 PSI 0 AUTO METER PRODUCTS INC. c 2004-6463 0 10 20 10 20 BOOST VAC In.Hg
More informationDraper Platform Adaptation Bundle
Draper Platform Adaptation Bundle 7050-Series Self-Propelled Forage Harvester 900D-Series Draper Platform RC042050 Operator s Manual Includes installation, operating, adjustment, technical, repair parts
More informationINSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT
INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT 85.0664.00 R Warranty ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May
More information