Microprocessor Controlled Dental Vacuum System Installation Manual

Size: px
Start display at page:

Download "Microprocessor Controlled Dental Vacuum System Installation Manual"

Transcription

1 Microprocessor Control System Installation Manual Microprocessor Controlled Dental Vacuum System Installation Manual Effective Date: 05-Aug-05 Review this entire booklet before starting any mechanical or electrical work. Please contact RAMVAC if you have any questions. RAMVAC 3100 First Avenue Spearfish SD Phone (800) 5-RAMVAC (800) (605) Fax (605) Effective Date: 05-Aug-05

2 MPC Installation Manual RAMVAC Dental Vacuum System Table of Contents Page MPC Installation Overview Pre-Installation Note... 2 Component List... 3 Understanding the System... 4 System Electrical Schematic... 4 Power Unit System Schematic... 5 Equipment Installation Sequence... 5 Vacuum Pressure Switch Installation... 6 Vacuum Controller Adjustments... 7 Vacuum Pressure Switch Adjustments... 7 Overhead Piping Adjustments... 8 Autowash Installation... 9 MPC Utility Control Mechanical Installation MPC System Component Diagram Component Wiring Connection Chart MPC System Startup References MPC PLC LED Chart MPC Covert Function Chart MPC Overt Function Chart Page 1 of 18

3 RAMVAC Dental Vacuum System MPC Installation Manual Pre-Installation Note All Pre-Installation work should be completed prior to the steps in this manual. Please refer to the Dental Vacuum System Installation Guide, and if included with your project, the RAMVAC Submittal Book. Please call RAMVAC if you have any questions Page 2 of 18

4 MPC Installation Manual RAMVAC Dental Vacuum System Component List Item Quantity Description/Comments Supplier This Document 1 each MPC System Installation Manual Booklet RAMVAC Documentation 1 each MPC Clinic Guide RAMVAC Power Units As ordered See Proposal, Submittal Book (if supplied) and/or ID label on each Power Unit and compare with Packing List RAMVAC S1 Electrols As ordered Attached to each Power Unit RAMVAC 3 Phase Starter Box As ordered One for each Power Unit with 3 Phase Motors Included only if installation uses three phase electrical power Separating Tanks As ordered See Proposal, Submittal Book (if supplied) and/or ID label on each tank and compare with Packing List Utility Control 1 each Enclosure with micro-processor, terminal boards, and ancillary devices RAMVAC RAMVAC RAMVAC Pressure (vacuum) Switch 1 each Vacuum Strength Monitoring Device RAMVAC Autowash Valves (if ordered) As ordered For tanks and/or piping RAMVAC Autowash Tank Nozzle Assemblies (if ordered) As ordered Tank mounted wash down nozzle RAMVAC Remote Control Panel 1 each Locate in clinic area RAMVAC Disconnects 1 each One for each Power Unit Customer Breakers 1 each One for each Power Unit Customer Wiring, breaker to disconnect 1 each One for each Power Unit Customer Wiring, disconnect to S1 Electrols (Single Phase) 1 each For Power Units Customer Wiring, disconnect to Starter (Three Phase) 1 each For Power Units Customer Wiring, S1 Electrols to Starter (Three Phase) 1 each For Power Units (6 ft. length supplied) RAMVAC Wiring, S1 Electrols to Motor As ordered Factory Installed RAMVAC Wiring, Pressure (vacuum) switch to Utility Control 1 set See MPC Wiring Diagram Customer Wiring to Autowash (if ordered) 1 set See MPC Wiring Diagram Customer Wiring to Remote Control Panel 1 set See MPC Wiring Diagram Customer Wiring, S1 Electrols to Utility Control 1 set See MPC Wiring Diagram Customer Page 3 of 18

5 RAMVAC Dental Vacuum System MPC Installation Manual Understanding the System RAMVAC MPC systems automatically respond to demand so that clinicians always have the power they need for safe, effortless operation while minimizing energy consumption and hardware use. The system automatically selects the pump with the lowest run-time. After a 30 to 120 second period of constant low pressure, an adjustable pressure switch signals the microprocessor to turn on Power Units as needed to maintain desired vacuum strength. After the system returns to a constant normal vacuum strength for a period of 15 minutes, unneeded power units are shut down. This alternation with record keeping makes sure your pumps get used evenly with no individual pump working longer than the others. If the Autowash option is selected, the microprocessor also controls tank wash down cycles and eliminates the need for additional timers and relays. Multiple pumps automatically selected to run by the computer minimize electrical consumption by operating according to demand. Multiple pumps offer the advantage of extending service life by reducing the operating hours of any one pump. Multiplexing inherently adds to backup capacity by decreasing dependency on any one device. System Electrical Schematic On/Off 5 wires Min. 18 AWG Wire Plug into 115v power Vacuum Pressure Switch Fault 2 wires Min. 18 AWG Wire Remote Switch Panel MPC Enclosure 2 wires Min. 18 AWG Wire 4 wires, min. 18 AWG Wire, to each S1 Electrol Autowash Solenoid Number of Power Units and S1 Electrols may vary Page 4 of 18

6 MPC Installation Manual RAMVAC Dental Vacuum System Power Unit System Schematic In addition to the MPC system, each individual power unit has a series of electrical and plumbing connections required to do its job. Since this is a generalized diagram, your installation may vary slightly. Factors such as number of tanks and selected accessories will affect your specific installation. Exhaust To Outside Breaker Disconnect HVE Control Signal from MPC Enclosure Facility Vacuum Piping S-Type Filter Required by the Bison 7 & 9 Optional with Bison 3 & 5 Power Gases Continue To Pump Starter (3 phase only) S1 Electrols Tank Power To Motor Liquids and Solids Drain When Vacuum is Off Power Unit Equipment Installation Sequence For the easiest and most efficient installation, equipment should be installed in the following sequence: 1. Tanks... See Separating Tank Installation Booklet 2. Power Units... See Dental Vacuum Installation Booklet 3. Vacuum Pressure Switch... See Page 6 4. Auto Wash Installation... See Page 9 5. MPC Control Mechanical... See Page Component Wiring... See Page 12 Page 5 of 18

7 RAMVAC Dental Vacuum System MPC Installation Manual Vacuum Pressure Switch Installation Vacuum Pressure Switch Assembly Location: Near vacuum line from treatment room; Near Separating Tank(s). Environment: Free from excessive vibration. Non-corrosive atmosphere. Ambient temperature 32 F to 104 F (0 to 40 C) Mount: On vertical surface minimum 24 above Separating Tank Inlet(s). Connect Vacuum Pressure Switch to Vacuum Line Hose Barb Attach customer/contractor supplied vacuum hose to hose barbs. a. Connect switch hose barb to treatment room vacuum line hose barb. b. Use ¼ I.D. metal or plastic tubing c. Tubing must not collapse under 15 Hg vacuum (-7.5psi) or restrict airflow in any way. To Power Units Hose Barb To Power Units Vacuum Line From Treatment Rooms Page 6 of 18

8 MPC Installation Manual RAMVAC Dental Vacuum System Adjusting the Vacuum Controller Do NOT Adjust the Vacuum Controller if: Any valves are open. Your system has vacuum leaks Vacuum is weak only when more than 2/3 of the rated number of vacuum devices are open. Warning: You can damage equipment by making improper vacuum controller adjustments. Do not exceed motor full load amperes. Please contact RAMVAC if you are at all uncertain about this adjustment. 1. Close all vacuum valves (high volume evacuators, saliva ejectors, surgical suctions) and close any other treatment room vacuum devices (nitrous oxide scavengers, vacuum sinks, vacuum cuspidors). 2. Disconnect inlet line to vacuum unit and cap off inlet. 3. Remove vacuum controller filter and loosen lock-nut. Lock-Nut Adjustment Nut 4. Manually turn vacuum unit on and turn adjustment nut to raise or lower vacuum pressure. 5. When vacuum gauge reaches desired reading, tighten lock-nut and replace filter. 6. Manually turn vacuum unit off. 7. Uncap inlet and reconnect inlet line to vacuum unit. 8. Repeat steps 1 to 7 for each vacuum unit and then adjust Vacuum Pressure Switch. Adjusting Vacuum Pressure Switch For typical installations, the Vacuum Pressure Switch is factory set at 6 inches of mercury. For atypical installations requiring higher vacuum, such as those with overhead piping, you may need to adjust the switch to a higher setting. Adjustment Compartment cover NOTE: ** Adjust the pressure switch to 1 below the Vacuum Controller pressure setting. ** 1/2 turn of Adjustment Screw adjusts vacuum level approximately 5 HG. 1. Open Wiring Compartment cover and disconnect wires from Com and NC terminals. Insulate wires from the pressure switch case and each other. 2. Open treatment room vacuum devices until the vacuum gauge indicates a vacuum reading 1 below the Vacuum Controller setting. 3. Apply a continuity tester across Com and NC terminals of pressure switch. 4. Open Adjustment Compartment cover and adjust pressure switch by turning the adjustment screw until the circuit closes as indicated on your tester. Wiring Compartment cover 5. Re-connect wires, close the Adjustment Compartment and Wiring Compartment covers. Page 7 of 18

9 RAMVAC Dental Vacuum System MPC Installation Manual Overhead Piping Adjustments In order for the MPC system to work properly, the correct adjustment must be set on the: 1. Power Unit s Vacuum Controller 2. Vacuum Pressure Switch The factory settings are correct and should not be changed for installations with: 1. Below grade piping with a Maximum Lift Height to the separating tank of 7 feet or less. 2. Overhead piping with a Maximum Lift Height of 7 feet or less. Note: Adjustments on this page can only be made to Pressure Switch shown below. Contact RAMVAC if you do NOT have this switch. What s Maximum Lift Height? It s the greatest vertical distance water must travel uphill in the vacuum system. To determine Maximum Lift Height, measure the greatest distance water must travel uphill from the lowest point to the highest point in the system. Be sure to check the height of all piping and hoses in the mechanical room and all treatment rooms. For below grade piping with a lift height to the Separating Tank greater than 7 feet, or overhead piping with a lift height greater than 7 feet the following adjustments must be made: Adjust the Vacuum Controller: 1. Measure the maximum lift height. 2. Adjust vacuum controllers to correspond with Maximum Lift Height as shown in the chart to the right. 3. See Adjusting the Vacuum Controller and Adjusting the Vacuum Pressure Switch. Warning: Do not exceed motor full load amperes. Please contact RAMVAC if you are at all uncertain about this adjustment. Maximum Lift Height Vacuum Controller Setting 7 Feet 7.5 Hg 8 Feet 8.3 Hg 9 Feet 9.2 Hg 10 Feet 10.2 Hg 11 Feet 11.0 Hg 12 Feet 12.0 Hg Page 8 of 18

10 MPC Installation Manual RAMVAC Dental Vacuum System Autowash Installation These steps detail the mechanical installation of the Autowash components. For electrical details, see MPC System Component Diagram. Make Connections According To Diagram Water Valve RAMVAC supplied Mount with valve body below coil. Comply with flow direction arrows located on valve body. 3/8 soft copper or equivalent Customer Supplied Manifold Customer Supplied Tank Spray Nozzle Assembly RAMVAC Supplied Water Filter Customer Supplied Autowash Tank Installation (for 2 or more tanks) Facility Vacuum Lines (from Treatment Rooms) Autowash Spray Nozzles To Power Units Page 9 of 18

11 RAMVAC Dental Vacuum System MPC Installation Manual MPC Utility Control Mechanical Installation Mount the MPC Enclosure to a vertical surface in a mechanical room that meets the following requirements: Adequate working space and lighting Ambient temperature between 32 F (0 C) and 104 F (40 C) Relative humidity between 20% and 90% No condensation occurs due to sudden temperature changes Protection from excessive shocks and vibrations Protection from corrosive or inflammable gases At least 8 (200 mm) from high voltage power Page 10 of 18

12 MPC Installation Manual RAMVAC Dental Vacuum System MPC System Component Diagram (3 Pump System shown) A B C E F G D H I J K L K L K L M N O O O P A B C D E F G H I J K L M N O P Programmable Logic Controller (PLC) Input Power Terminal Board Ground Lug Transformer CX Terminal Board Remote Panel Terminal Board C1 Terminal Board Transformer Fuse (1 amp AGC) CX Fuse (½ amp AGC) VIN Fuse (½ amp AGC) Motor Running Signal Relays (12v DC) Pump Start Relays (24v AC) Autowash Relay Pressure Switch Terminal Board S1 Electrols Terminal Boards Autowash Terminal Board Page 11 of 18

13 RAMVAC Dental Vacuum System MPC Installation Manual Component Wiring Wire Vacuum Pressure Switch to MPC Terminal Blocks inside MPC Enclosure Min. 18 AWG Wire Pressure Switch COM COM N/C N/C Wire Nuts Wire Remote Control Panel to MPC On/Off Min. 18 AWG Wire Remote Panel Fault 5 Wire Nuts Wire Autowash Solenoid to MPC Autowash Solenoid Leads Min. 18 AWG Wire Auto Wash Wire Nuts AW1 AW2 Wire S1 Electrols to MPC S1 Electrol #1 Repeat S1 Electrols hookup for every power unit in your installation 5 6 F H F G H 5 6 J K Min. 18 AWG Wire Connect terminals to corresponding S1 Electrol connectors (One set of terminals for each S1 Electrols) Page 12 of 18

14 MPC Installation Manual RAMVAC Dental Vacuum System Connection Chart (5 Pump System shown) Contractor Wiring Component Utility Control Enclosure Factory Wired To Terminal Board Remote Control Panel Remote Panel On/Off switch pigtail 1 terminal 1 CX Terminal Board PLC Input - On/Off switch pigtail 2 terminal 2 PLC Input 0 light cmn pigtail 3 terminal 3 CY Terminal Board PLC Output + On light pigtail 4 terminal 4 PLC Output 20 Fault light pigtail 5 terminal 5 PLC Output 21 Autowash Solenoid Autowash terminal 1 terminal AW1 Autowash Relay Terminal terminal 2 terminal AW2 Autowash Relay Terminal Pressure Switch Pressure Switch common terminal COM CX Terminal Board PLC Input CX norm closed terminal N/C PLC Input 5 S1 Electrols #1 S1 Electrols #1 S1 terminal connector 5 terminal 5 PLC Input 1 S1 terminal connector 6 terminal 6 CX Terminal Board PLC Input CX S1 terminal connector F terminal F C1 Terminal Board PLC Output C1 S1 terminal connector H terminal H PLC Output 23 S1 Electrols #2 S1 Electrols #2 S1 terminal connector 5 terminal 5 PLC Input 2 S1 terminal connector 6 terminal 6 CX Terminal Board PLC Input CX S1 terminal connector F terminal F C1 Terminal Board PLC Output C1 S1 terminal connector H terminal H PLC Output 24 S1 Electrols #3 S1 Electrols #3 S1 terminal connector 5 terminal 5 PLC Input 3 S1 terminal connector 6 terminal 6 CX Terminal Board PLC Input CX S1 terminal connector F terminal F C1 Terminal Board PLC Output C1 S1 terminal connector H terminal H PLC Output 25 S1 Electrols #4 S1 Electrols #4 S1 terminal connector 5 terminal 5 PLC Input 4 S1 terminal connector 6 terminal 6 CX Terminal Board PLC Input CX S1 terminal connector F terminal F C1 Terminal Board PLC Output C1 S1 terminal connector H terminal H PLC Output 26 S1 Electrols #5 S1 Electrols #5 S1 terminal connector 5 terminal 5 PLC Input 5 S1 terminal connector 6 terminal 6 CX Terminal Board PLC Input CX S1 terminal connector F terminal F C1 Terminal Board PLC Output C1 S1 terminal connector H terminal H PLC Output 27 Page 13 of 18

15 RAMVAC Dental Vacuum System MPC Installation Manual MPC System Startup 5 Power Units or Less Please call RAMVAC Tech Service with questions or, if at any time during Start-Up LED or equipment response is not as described below. Step PLC LED response (See MPC PLC LED Chart for location of LEDs) 1. Close all treatment room vacuum valves. none Ensure power is available to all S1 Electrols as indicated by the illumination of each S1 Electrols Power On light. 2. Plug power cord into 115v AC receptacle. PWR and RUN LEDs illuminate. Input LED #7 (vacuum weak) illuminates. 3. Start system by pressing Remote Control Panel on/off button to on. The Power Units with the least total run time turns on. if Power Unit #1 turns on: if Power Unit #2 turns on: if Power Unit #3 turns on: if Power Unit #4 turns on: if Power Unit #5 turns on: When vacuum becomes strong : 4. Create weak vacuum signal by removing vacuum line from vacuum pressure switch. After a 30 second delay, additional Power Units turn on with a second delay between each additional power unit. when Power Unit #1 is on: when Power Unit #2 is on: when Power Unit #3 is on: when Power Unit #4 is on: when Power Unit #5 is on: 5. Restore a strong vacuum signal by reattaching the vacuum line to the vacuum pressure switch. After a minimum run time of 15 minutes, the additional Power Units turn off with a 15 minute period of strong vacuum, between each power unit. when Power Unit #1 stops: when Power Unit #2 stops: when Power Unit #3 stops: when Power Unit #4 stops: when Power Unit #5 stops: Input LED #0 (remote panel switch on ) illuminates. Input LED #1 and Output LED #3 illuminate. Input LED #2 and Output LED #4 illuminate. Input LED #3 and Output LED #5 illuminate. Input LED #4 and Output LED #6 illuminate. Input LED #5 and Output LED #7 illuminate. Input LED #7 (vacuum weak) goes out. Input LED #7 (vacuum weak) illuminates. Input LED #1 and Output LED #3 illuminate. Input LED #2 and Output LED #4 illuminate. Input LED #3 and Output LED #5 illuminate. Input LED #4 and Output LED #6 illuminate. Input LED #5 and Output LED #7 illuminate. Input LED #7 (vacuum weak) goes out. Input LED #1 and Output LED #3 extinguish. Input LED #2 and Output LED #4 extinguish. Input LED #3 and Output LED #5 extinguish. Input LED #4 and Output LED #6 extinguish. Input LED #5 and Output LED #7 extinguish. 6. After 3 hours of single pump operation with vacuum remaining strong: The Power Unit that was running, will turn off and the next in-line Power Unit will take over. Page 14 of 18

16 MPC Installation Manual RAMVAC Dental Vacuum System MPC PLC LED Chart FLT RUN PWR L H Input (L) LEDs LED illuminates when: Output (H) LEDs LED illuminates when: 0 Remote Panel Switch is On 0 Turn On Remote Panel System On/Off light 1 Pump #1 confirmed On 1 Turn On Remote Panel Fault light 2 Pump #2 confirmed On 2 Turn On Autowash solenoid (if installed) 3 Pump #3 (if installed) confirmed On 3 Turn On Pump #1 4 Pump #4 (if installed) confirmed On 4 Turn On Pump #2 5 Pump #5 (if installed) confirmed On 5 Turn On Pump #3 (if installed) 6 (not used) 6 Turn On Pump #4 (if installed) 7 Pressure Switch closed vacuum is weak 7 Turn On Pump #5 (if installed) MPC CONTROL LEDS PWR Power light illuminates when power is applied to MPC control. RUN Run light illuminates when MPC control is functioning. FLT Fault light illuminates if MPC control is malfunctioning. Page 15 of 18

17 RAMVAC Dental Vacuum System MPC Installation Manual NOTES Page 16 of 18

18 MPC Installation Manual RAMVAC Dental Vacuum System NOTES Page 17 of 18

19 RAMVAC Dental Vacuum System MPC Installation Manual NOTES Page 18 of 18

20 MPC Installation Manual RAMVAC Dental Vacuum System Microprocessor Control Installation Manual Effective date: 15-Mar-05 Spearfish, SD FAX (605) First Avenue (800) 5-RAMVAC Page 19 of 18

Dental Vacuum System. Installation Overview

Dental Vacuum System. Installation Overview Dental Vacuum System Installation Overview This guide contains site preparation and installation instructions for RAMVAC Bulldog QT and Bison Dental Vacuum Systems with S1 Electrols. It is recommended

More information

Section. Vacuums. 866-DTE-INFO 147

Section. Vacuums. 866-DTE-INFO  147 Section Vacuums 866-DTE-INFO www.dentalez.com 147 Vacuums How to size your RAMVAC Dental Vacuum. Method One: The Precise Equipment Selection Method, pick a custom system. Works for any application. Select

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

PRECISION UK Ltd DUPLEX AGSS PLANT

PRECISION UK Ltd DUPLEX AGSS PLANT DUPLEX AGSS PLANT Contents Page Section Page Product Description General 3 AGSS Plant 3 AGSS Remote Switch 3 Operation General 4 Safety General 5 Installation General 5 Mechanical 5 Electrical 7 Wiring

More information

PowerAir Compressor Installation

PowerAir Compressor Installation PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model

More information

User s and Installation Manual

User s and Installation Manual Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 User s and Installation Manual We Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...4

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Utility Distribution System

Utility Distribution System READ AND SAVE THESE INSTRUCTIONS Utility Distribution System Installation, Operation and Maintenance Manual Warning!! Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream Dry Vacuum System Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...3 Purpose of this Manual....3 Safety

More information

ClassicSeries Compressor Installation

ClassicSeries Compressor Installation ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:

More information

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual Model AM2 M40 Panel Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to the

More information

INSTALLATION INSTRUCTIONS BACK-UP BRAKE FULLY AUTOMATIC

INSTALLATION INSTRUCTIONS BACK-UP BRAKE FULLY AUTOMATIC INSTALLATION INSTRUCTIONS BACK-UP BRAKE FULLY AUTOMATIC Providing Mobility for the Physically Challenged Since 1952 37 Daniel Road West, Fairfield, NJ 07004-2521 Phone: (973) 808-9709 Fax: (973) 808-9713

More information

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation

Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Procenter Delivery Mounted on a Free Standing Treatment Console (FTC) Installation Electrical Requirements: 24 VAC, 3.2 Amp 13VAC, 2 Amp Attention These instructions apply to Midmark cabinetry. For other

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information

Solenoid Valve Output Module IC693MDL760 Product Description

Solenoid Valve Output Module IC693MDL760 Product Description GFK-A November 000 Solenoid Valve Output Module ICMDL0 Product Description Description This ICMDL0 output module provides eleven pneumatic outputs and five VDC sourcing outputs. For each pneumatic output,

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

PowerMax Surgical Suction Producers

PowerMax Surgical Suction Producers PowerMax Surgical Suction Producers Models: PM-1, PM-3, PM-4 Installation & Operation 10496800 Rev. B Table of Contents Section 1 About PowerMax...1 Section 2 Specifications & Model Selection...3 2.1

More information

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks. ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks. 1. Check log book for incomplete compliance for further operation. 2.

More information

Slide Freedom Automatic Spray Unit Item # 43200

Slide Freedom Automatic Spray Unit Item # 43200 Just plug and spray Easy to use, no hard wiring required Save money and save time Operate more productively Works with Slide aerosol cylinders (purchased separately) Works with Slide bulk/liquid products

More information

SECTION B1: MACHINE COMPONENTS

SECTION B1: MACHINE COMPONENTS SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,

More information

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS TRANSFER PUMP INSTRUCTIONS P/N 14251NOS A5048-SNOS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2011 EFFECTIVE: MAY, 2011 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 213-0066 L-R / 214-0066 R-L ADC-66 Conveyor Dishwasher 2

More information

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET I-736 Pg. 1 of 10 Summary The 258BD-200C Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent buildup and eliminate odors. The 258BT-200C Trash Master is

More information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start) AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306)

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306) INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Axiom Industries Ltd. 2615 Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) 651-1815 Fax: (306) 242-3373

More information

PARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008

PARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008 EFFECTIVE: MAY, 2008 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2 211-0044L-R

More information

Hydropak Booster Systems. Series motralec

Hydropak Booster Systems. Series motralec Series 6000 Hydropak Systems motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide 8/28/00 TROUBLESHOOTER S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinator Check water flow through Flow Controller

More information

Service Manual for Battery Control Center

Service Manual for Battery Control Center Service Manual for Battery Control Center P/N 82 E0071 00 (Ref. 81 1317) June, 1999 Battery Control Box Operation Charging Circuit This function charges the coach battery from the engine alternator while

More information

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232

More information

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 160.80-PW4 (1099) Form: 160.80-PW4 (215) FIELD CONNECTIONS ROTARY SCREW CHILLER WITH GRAPHIC CONTROL CENTER AND YORK MOD

More information

AMEREC STEAMBATH GENERATOR (MODEL: AV2, 2KW/120 VOLT) SAVE THESE INSTRUCTIONS

AMEREC STEAMBATH GENERATOR (MODEL: AV2, 2KW/120 VOLT) SAVE THESE INSTRUCTIONS WARNING Electrical grounding is required on all AMEREC steambath generators. All electrical supplies should be disconnected when servicing generator. All wiring must be installed by a licensed electrical

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning

More information

Asepsis 21 Delivery Unit

Asepsis 21 Delivery Unit INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.

More information

LPT50BRD (8x11x3 Enclosure)

LPT50BRD (8x11x3 Enclosure) LPT50BRD (8x11x3 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines Installation and Users Manual For the following Prelube Kits: VARNA Products P/N 6423 Kit for 208 VAC 3 Phase VARNA Products

More information

348002K/348012K Manifold Block Style Service Manual 12/2000

348002K/348012K Manifold Block Style Service Manual 12/2000 348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation

More information

A-dec 311 Dental Chair and Related Systems

A-dec 311 Dental Chair and Related Systems Pre-Installation Guide A-dec 311 Dental Chair and Related Systems A-dec 311 Dental Chair with 332 Radius -Style Delivery System and 572 Dental Light This document contains technical specifications for

More information

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems Series 6000 FILE NO: 62.10 DATE: Feb. 15, 1999 SUPERSEDES: 62.10 DATE: Dec. 15, 1997 Hydropak Booster Systems Series 6000 Hydropak Listed Armstrong Pumps introduces the Series 6000 HYDROPAK line of packaged

More information

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL EFFECTIVE JANUARY 10, 2018 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 47681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL SDKIT-730 & SDKIT-734 100% Bolt-On 150 PSI Train Horn System for 2011-2015 F-250 & F-350 Super Duty P/N SDKIT-730 P/N SDKIT-734 Thank you for purchasing a Kleinn Air Horns

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings Date: Job Name: Contractor: Contractor or Order No.: Engineer: Agent: Agent P.O. No.: Date Ordered: Date Required:

More information

SERVICE MANUAL. K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - NOTICE - K40GL Shown

SERVICE MANUAL. K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - NOTICE - K40GL Shown SERVICE MANUAL K Series Gas Kettles 2/3 Jacketed Stationary and Tilting K20GL K40GL K60GL K20GLT K40GLT K60GLT ML-136090 ML-136091 ML-136092 ML-136094 ML-136095 ML-136096 K40GL Shown - NOTICE - This Manual

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

2002 Buick Rendezvous - AWD

2002 Buick Rendezvous - AWD 2002 Buick Rendezvous - AWD DTC P0410 Description The control module activates the secondary air injection (AIR) system by grounding both the pump relay and the vacuum control solenoid control circuits.

More information

DOC # DOCSST-D 08/16/99

DOC # DOCSST-D 08/16/99 DOC # DOCSST-D 08/16/99 Wired Rite Systems 5793 Suite A, Skylane Blvd., Windsor Ca. 95492 Phone: (800) 538-7483 Or (707) 838-1122 Fax: (800) 525-7483 WEB: http://www.wiredrite.com E-MAIL: Info@wiredrite.com

More information

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717 AQUA-LAB AX, BX, TX CHEMICAL DISPENSING SYSTEM User Manual REV A 4000133 reva0717 Hydra-Flex, Hydra-Flex, Inc. 2017 Inc. 2017 TABLE OF CONTENTS Overview 1 Features 1 Specifications 1 Installation Instructions

More information

SECTION B: SYSTEM OPERATING COMPONENTS

SECTION B: SYSTEM OPERATING COMPONENTS SECTION B: SYSTEM OPERATING COMPONENTS A brief description of the machine, Cable Processor Module and tooling will provide a better understanding of the various functions of the IMA system. SECTION B1:

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

EZ SDI TM Booster Pump Assembly

EZ SDI TM Booster Pump Assembly EZ SDI TM Booster Pump Assembly Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email: info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions

More information

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A

More information

PS24/AC Volt AC 16 Amp

PS24/AC Volt AC 16 Amp ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage-

More information

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is

More information

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007 Instruction Sheet PA-00281 October 2007 PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls THE FLEXIBLE

More information

L5000 Plus. Installation & Setup Guide

L5000 Plus. Installation & Setup Guide L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 473681 Vari-Green Motor and Controls Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,

More information

Model LA 4400 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller ISIMET LA Series Model LA 4400 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller with integral 24-hr. programmable time clock operates

More information

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 Model Number:

More information

Canadair Regional Jet 100/200 - Auxiliary Power Unit

Canadair Regional Jet 100/200 - Auxiliary Power Unit 1. INTRODUCTION The auxiliary power unit (APU) is installed within a fireproof titanium enclosure in the aft equipment compartment. The APU is a fully automated gas turbine power plant which drives an

More information

forest dental australia affordable excellence + designer friendly

forest dental australia affordable excellence + designer friendly Component Catalogue 204 table of contents section pages light service items............................................ 2-3 handpiece controls..............................................4 arm systems................................................

More information

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS 4.0 BASIC

More information

ATD WATT INVERTER

ATD WATT INVERTER ATD-5954 1500 WATT INVERTER Welcome. This ATD product has been carefully engineered and manufactured to give you dependable operation. Please read this manual thoroughly before operating your new ATD product,

More information

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR SD-13-4793 Bendix M-21 and M-22 AntiLock Modulator Assembly CONNECTOR DELIVERY (CAST-IN ID #2) (CAST-IN ID #3) DELIVERY (CAST-IN ID #2) (CAST-IN ID #1) DELIVERY DELIVERY (CAST-IN ID #1) CONNECTOR MOUNTING

More information

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N ELECTRIC FUEL PUMPS P/N 80000100, 80000101, & 80000102 FUEL PRESSURE REGULATOR P/N 80000103 Installation Instructions 199R10583 These instructions must be read and fully understood before beginning the

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

Self Cleaning Hood System Installation, Operation, and Maintenance Manual Self Cleaning Hood System Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to

More information

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G) Part B, Section 1 This section covers the following unit configurations. Model 3100 3400 3500 Voltage 1, 2 Pump Piston (E, F, or G) Manifold 4-Port (A) 6-Port (B or C) Control UniScan (1) B 1-0 B 1-1 Section

More information

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12

More information

FBD-NT Press Brake Installation Guide

FBD-NT Press Brake Installation Guide FBD-NT Press Brake Installation Guide Summary...2 Environmental conditions...2 Power supply...2 Machine installation...3 Location...4 Carrying...5 Using a crane...5 Using rollers...6 Foundation...7 Cleaning...7

More information

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Installation Operation & Maintenance Manual Oil-Free (Dry) Rotary Vane Vacuum Pump Systems Part No. 9983-0000-S07 / November 2018 OIL-FREE (DRY) ROTARY VANE VACUUM PUMP SYSTEMS TABLE OF CONTENTS CUSTOMER

More information

LCN 7900 SERIES CONTROL BOXES

LCN 7900 SERIES CONTROL BOXES LCN 7900 SERI CONTROL BOX Control Boxes Heavy duty, surface mounted control box contains one or two electrically controlled pneumatic circuits. Air filtration, pneumatic regulation, and system timing is

More information

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Utility Distribution Systems Installation, Operation, and Maintenance Manual Utility Distribution Systems Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

JD TRIPLE EGRESS TRIPLE EGRESS SECTION

JD TRIPLE EGRESS TRIPLE EGRESS SECTION JD 72-7420 TRIPLE EGRESS TRIPLE EGRESS SECTION Assembly Section 5-1 ASSEMBLY - TRIPLE EGRESS, CAB TRIPLE EGRESS MOUNTING Park the tractor on a flat, hard, level surface. Lower both side decks down onto

More information

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND

More information

Installation, Operation & Maintenance Instructions for MF Series Solution Feeders

Installation, Operation & Maintenance Instructions for MF Series Solution Feeders INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Startup Procedure ) Close isolation valve between feeder and system connection point 2) Fill reservoir,

More information

ORDERING INFORMATION SPECIFICATIONS APPLICATION

ORDERING INFORMATION SPECIFICATIONS APPLICATION ORDERING INFORMATION UNIVERSAL MODELS The ordering part number for the universal model is 82UNIVERSAL. The 82UNIVERSAL comes with remote flame sense active. For internal flame sense, the supplied universal

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Installation Suggestions

Installation Suggestions Installation Suggestions P/N 52200-98 Suggestions For Installing The Balboa 05-28-14 Introduction The Balboa consists of a controller that opens and closes valves that supply water to four groups of jets.

More information

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves FS2 Valves Solenoid Powered to Close / Auto Reset Butterfly Valves Part of the F Series of easily installed, compact, air intake valves for diesel engine emergency shut down. Application The FS2 version

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum

More information

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013 PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B Release 1.0 April 5, 2013 Electrical Test Instruments, Inc. 1301 Avondale Road, Suite J New Windsor, MD

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe) FS3 Valves Solenoid Powered to Open / Spring to Close (failsafe) Part of the F Series of easily installed, compact, air intake valves for diesel engine emergency shut down. Application The FS3 version

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Motorized Stainless 2-Way Valves

Motorized Stainless 2-Way Valves Installation and Operation Manual Motorized Stainless 2-Way Valves Safety Valve ETV Applications WARNING This Heat-Timer valve is strictly an operating valve; it should never be used as a primary limit

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

HP FUEL PUMPS P/N & Installation Instructions 199R10569

HP FUEL PUMPS P/N & Installation Instructions 199R10569 HP FUEL PUMPS P/N 12-700 & 12-890 Installation Instructions 199R10569 WARNING! THESE INSTRUCTIONS MUST BE READ AND FULLY UNDERSTOOD BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information