1 Mounting Systems Applications Overview Version 1.2 March 2013

2 tritec Mounting Systems: Applications Overview I. Pitched Roof: Roof-Top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND on tiles Insertion system Clip system 1.2 TRI-STAND on shingles 1.3 TRI-STAND on corrugated panel roofs 2. Trapezoidal sheet metal roof 2.1 TRI-VENT Horizontal installation Vertical installation 2.2 TRI-STAND Insertion system with rivet SafeClick Clip system with rivet SafeClick 2.3 TRI-STAND Aero Special Solution Mounted transversely to UP-TS profiles Mounted lengthwise to UP-TS profiles 3. Sheet metal roof 3.1 TRI-STAND Insertion system on sheet metal clips Clip system on sheet meal clips 3.2 TRI-STAND Aero Special Solution Mounted on clamps for sheet metal transversely to UP-TS profiles Mounted on clamps for sheet metal lengthwise to UP-TS profiles II. Pitched Roof elevation 1. TRI-STAND triangle installation with insertion system 1.1 Fastening with roof hooks 1.2 Fastening with hanger bolts 2. TRI-STAND triangle installation with clip system Special Solution 2.1 Fastening with roof hooks 2.2 Fastening with hanger bolts III. Pitched Roof: Roof Integrated 1. TRI-ROOF on wooden purlins 2. TRI-ROOF on steel purlins 3. TRI-ROOF on tile battening IV. Flat Roof 1. Flat roof with low load capacity 1.1 TRI-STAND Aero 1.2 TRI-STAND east-west support 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation Insertion system Clip system Special Solution 2.2 TRI-STAND upright installation Insertion system Clip system Special Solution V. Facade 1. TRI-STAND vertical installation 2. TRI-STAND inclined installation

3 I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.1 TRI-STAND on tiles Insertion system 35.7 (module mm) * number of modules + 69 mm 69 module mm 69 module mm 69 module module TS profile PV module PV module UP-L, UP or UP-S module mm for standard tiles for flat beaver tail tiles for shingles and slate Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution different profile gauges for both light-weight designs and statically optimized constructions one or several roof hook variants for virtually any application optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation UP-C / TS-C profile TS insertion profile TS central rail roof hooks TS edging tool for high static loads connector secure connection of profiles insertion profile for standard frame heights additional reinforcement for vertical module insertion and a pressure load assumption of over 2,400 N/m 2 variable or fixed depending on type of tiles for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

4 I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.1 TRI-STAND on tiles Clip system UP-L, UP or UP-S PV module PV module for standard tiles for flat beaver tail tiles for shingles for large rafter spacings Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market for large rafter spacings since, by clipping, the module supports the system statics. different profile gauges for both light-weight designs and statically optimized constructions one or several roof hook variants for virtually any application optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation UP-C profile connector roof hooks variable or fixed for high static loads secure connection of profiles depending on type of tiles

5 I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.2 TRI-STAND on shingles (module mm) * number of modules + 69 mm 69 module mm 69 module mm module module TS profile PV module PV module On all types of shingle roofs with hanger bolts To be taken into account here: Fastening of counter-battening (min. 45/45 mm) must be able to withstand the additional loads. Set screws must be centrically set into the counter-battening. Asbestos-containing roof shingles may not be worked on. Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp different profile gauges for both light-weight designs and statically optimized constructions optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation no quality impairment of the subroof due to fastening screws in counter-battening UP-C / TS-C profile connector hanger bolts TS central rail TS edging tool for high static loads secure connection of profiles specifically for fiber cement shingles specifically for fiber cement shingles for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

6 I. Pitched-Roof: Roof-Top 1. Tiles, shingles, corrugated panels 1.3 TRI-STAND on corrugated panel roofs (module mm) * number of modules + 69 mm module mm 69 module mm 35.7 module module TS profile PV module UP-L, UP or UP-S PV module for all types of pitched roofs with profiled or corrugated surfaces for corrugated panels for corrugated fiber cement panels Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp optionally black profiles for visually attractive systems with black modules different profile gauges for both light-weight designs and statically optimized constructions horizontal and vertical module installation freely selectable degree of rear ventilation by means of different hanger bolt sizes solid fastening even for comparatively thick and soft insulation layers for high static loads UP-C / TS-C profile connector secure connection of profiles hanger bolts in different sizes (M8, M10, M12) TS central rail possibly required for insertion system TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

7 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.1 TRI-VENT Horizontal installation (width of module + 20) * number of modules - 20 (in mm) width of module 20 width of module width of module on trapezoidal sheet metal roofs on sandwich elements applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths Installation riveting instead of bolting carrier profiles for higher loads up to 2400 N/m 2 low cost and uncomplicated shipment thanks to few components no consequences due to heat expansion: modules are set on short rails, tension-free and without clipping suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses TRI-DESIGN software for optimum, standard planning and dimensioning of the system central and end module anchor each applicable for two different module widths carrier profile available in different lengths sealing rivets for fastening the carrier profiles drilling gauge for optimum alignment of drill holes TRI-VENT bending tool for secure fixation of end module anchors

8 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.1 TRI-VENT Vertical installation (length of module + 20) * number of modules - 20 (in mm) length of module 20 lower installation hole spacing installation hole spacing lower instal. upper instal. upper installation hole spacing 20 on trapezoidal sheet metal roofs on sandwich elements applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths Installation riveting instead of bolting carrier profiles for higher loads up to 2400 N/m 2 low cost and uncomplicated shipment thanks to few components no consequences due to heat expansion: modules are set on short rails, tension-free and without clipping no slipping of modules due to circlips suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses central and end module anchor each applicable for two different module widths carrier profile available in different lengths sealing rivets for fastening the carrier profiles drilling gauge for optimum alignment of drill holes circlips 2 pieces per module, suitable for all framed modules TRI-VENT bending tool for secure fixation of end module anchors

9 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.2 TRI-STAND Insertion system with rivet SafeClick height of module field = (length of module insertion mm) * number of modules + 69 mm drilling hole spacing = length of module insertion mm) on trapezoidal sheet metal roofs on sandwich elements Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work to clip marks optimum load distribution Installation quick and easy since only one setting is required for the drilling gauge module load possible up to 5400 N/m 2 location-optimized load distribution to all outward beads thanks to continuous rails horizontal and vertical module installation Number of rivet SafeClick is selected depending on roof load, bead space, trapezoidal sheet metal gauge and material (aluminium or steel). TS profile TS-M central rail rivet SafeClick drilling gauge rubber seal and rivet TS edging tool in aluminium or black for TRI-STAND insertion profiles quick and stable joining of SafeClick connections for optimum calibration of drill holes for optimum impermeability of the roof for edge-trimming the profiles

10 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.2 TRI-STAND Clip system with rivet SafeClick length of module / 5 length of module length of module * 0.6 (length of module + 20) * number of modules - 20 (in mm) 20 length of module / 5 * (in mm) length of module / 5 20 length of module / 5 length of module / 5 on trapezoidal sheet metal roofs on sandwich elements Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market Installation vertical module installation module load possible up to 5400 N/m 2 location-optimized load distribution to all outward beads thanks to continuous rails In case of interfering objects, the position of a UP-TS profile may be slightly changed without displacement of the entire module field. Number of rivet SafeClick is selected depending on roof load, bead space trapezoidal sheet metal gauge. center clips UP-TS profile rivet SafeClick drilling gauge in aluminium or black carrier profile for modules quick and stable joining of SafeClick connections for optimum calibration of drill holes

11 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.3 TRI-STAND Aero Mounted on clamps for sheet metal transversely to UP-TS profiles for module widths mm and mm shading angle V2A drilling screw 6.3 x 40 (Aero 80) 859 mm, Aero 100) 1062 mm (Aero 80) 859 mm, Aero 100) 1062 mm calculation as a function of the shading angle V2A drilling screw 6.3 x 40 hexagonal screw M10x25 A2 sliding nut M10 SafeClick UP-TS profile hexagonal screw M10x25 A2 sliding nut M10 SafeClick UP-TS profile Support directly on pitched trapezoidal sheet metal roofs with a southern orientation by means of SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 Mounting system suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm reduced dynamic and wind pressure load due to wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 and tested in the wind tunnel UP-TS profile TS-F angle wind baffle UP-C universal profile SafeClick universal profile for SafeClick connection with reinforcement and guide ribs for stable installation in two standard designs connector if necessary for the connection of continuous rails

12 I. Pitched-Roof: Roof-Top 2. Trapezoidal sheet metal roof 2.3 TRI-STAND Aero Mounted on clamps for sheet metal lenghtwise to UP-TS profiles for modue widths mm and shading angle Calculation as a function of the shading angle hexagonal screw M10x25 A2 sliding nut M10 UP-TS profile hexagonal screw M10x25 A2 sliding nut M10 UP-TS profile rubber seal drilling screw V2A 6.3x40 sealing rivets two alternatives to fix wind baffle plate special SafeClick vis à tête hexagonale M10x25 A2 self locking nut M10 Support directly on pitched trapezoidal sheet metal roofs with a east/west orientation by means of SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 Mounting system suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm reduced dynamic and wind pressure load due to wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 and tested in the wind tunnel UP-TS profile TS-F angle wind baffle UP-C universal profile SafeClick material optimised profile universal profile for SafeClick connection with reinforcement and guide ribs for stable installation in two standard designs connector if necessary for the connection of continuous rails

13 I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.1 TRI-STAND Insertion system on sheet metal clips height of module field = (length of module insertion mm) * number of modules + 69 mm 6.9 module mm 6.9 module mm 6.9 module mm 6.9 UP-L, UP or UP-S On sheet metal and Kalzip roofs by means of fastening on standing seams Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation clips fitting for different module frames fastening with flat head screws or hammerhead bolts sheet metal and Kalzip clips TS edging tool depending on type of roof, for different module frames profile for high static loads for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

14 I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.1 TRI-STAND Clip system on sheet metal clips 20 UP-L, UP or UP-S On sheet metal and Kalzip roofs by means of fastening on standing seams Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market optionally black profiles for visually attractive systems with black modules horizontal and vertical module installation clips fitting for different module frames fastening with flat head screws or hammerhead bolts sheet metal and Kalzip clips depending on type of roof, for different module frames profile for high static loads

15 I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.2 TRI-STAND Aero Mounted on clamps for sheet metal transversely to UP-TS profiles for module widths mm and mm shading angle V2A drilling screw 6.3 x 40 calculation as a function of the shading angle (Aero 80) 859 mm, (Aero 100) 1062 mm (Aero 80) 859 mm, (Aero 100) 1062 mm V2A drilling screw 6.3x40 hexagonal screw M10x25 A2 sliding nut M10 UP-L or UP profile hexagonal screw M10x25 A2 UP-L or UP profile sliding nut M10 sheet metal seam clamp sheet metal seam clamp Support on sheet metal roofs with southern orientation by means of standing seam or KalZip clips and SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm Mounting system reduced dynamic and wind pressure load by means of wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 standing seam and KalZip clips UP-L profile TS-F angle wind baffle depending on the type of roof material optimised profile with reinforcement and guide ribs for stable installation in two standard designs

16 I. Pitched-Roof: Roof-Top 3. Sheet metal roof 3.2 TRI-STAND Aero Mounted on clamps for sheet metal lengthwise to UP-TS profiles for module widths mm and mm shading angle (Aero 80) 859 mm, Aero 100) 1062 mm calculation as a function of the shading angle (Aero 80) 859 mm, Aero 100) 1062 mm hexagonal screw M10x25 A2 hexagonal screw M10x25 A2 hammer head bolt M10x20 A2 sliding nut M10 sheet metal seam clamp sliding nut M10 sheet metal seam clamp Support on sheet metal roofs with seast/west orientation by means of standing seam or KalZip clips and SafeClick Module installation cost benefit due to fast installation and low materials expenditure, generally without additional weighting manufacturer-conforming module installation at installation drill holes allows module loads of up to 5,400 N/m 2 suitable for all standard modules of a width of 790 to 810 mm and 990 to 1010 mm Mounting system reduced dynamic and wind pressure load by means of wind baffle fixed 20 angle: Reduction of shading clearances and thus higher performance per m 2 standing seam and KalZip clips UP-L profile TS-F angle wind baffle depending on the type of roof material optimised profile with reinforcement and guide ribs for stable installation in two standard designs

17 II. Pitched-Roof Elevation 1. TRI-STAND triangle installation with insertion system 1.1 Fastening with roof hooks module mm mm module mm shading angle for installation on pitched roofs with up to 20 roof pitch Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection roof hooks for fastening to the substructure on the roof TS edging tool for edge-trimming the profile For the insertion system, please comply with the module manufacturer s instructions.

18 II. Pitched-Roof Elevation 1. TRI-STAND triangle installation with insertion system 1.2 Fastening with hanger bolts module mm mm module mm shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection hanger bolts for fastening to the substructure on the roof TS edging tool for edge-trimming the profile For the insertion system, please comply with the module manufacturer s instructions.

19 II. Pitched-Roof Elevation 2. TRI-STAND triangle installation with clip system 2.1 Fastening with roof hooks module shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection roof hooks for fastening to the substructure on the roof

20 II. Pitched-Roof Elevation 2. TRI-STAND triangle installation with clip system 2.2 Fastening with hanger bolts module shading angle UP-L, UP or UP-S for installation on pitched roofs with up to 20 roof pitch Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection hanger bolts for fastening to the substructure on the roof For the insertion system, please comply with the module manufacturer s instructions.

21 III. Pitched-Roof: Roof Integrated 1. TRI-ROOF on wooden purlins (module mm) * number of modules + 69 mm 69 module mm 69 module mm 69 module mm 69 module mm with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile basic profile for vertical water drainage profile for horizontal water drainage For the insertion system, please comply with the module manufacturer s instructions.

22 III. Pitched-Roof: Roof Integrated 2. TRI-ROOF on steel purlins (module mm) * number of modules + 69 mm 69 module mm 69 module mm 69 module mm 69 module mm with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile basic profile for vertical water drainage profile for horizontal water drainage For the insertion system, please comply with the module manufacturer s instructions.

23 III. Pitched-Roof: Roof Integrated 3. TRI-ROOF on tile battening module mm 69 a b 170 module mm (module mm) * number of modules + 69 mm module mm with roof refurbishment and new roofs in combination with existing roof areas or as roof coverage over the whole area with purlin spaces of up to 2.5 m insertion system: Easy replacement of modules compatible with framed standard modules with standard tile cover, supply of complete sheet metal flashing which can be adjusted to the module size without special know-how optionally black profiles for visually attractive systems with black modules Impermeability discharge of rain water for the most part via modules specially developed water-bearing carrier profiles UP-I universal profile TR-H profile ridge and lateral flashings accessories for sealing valley basic profile for vertical water drainage profile for horizontal water drainage optional with standard tiles sealing strips, special adhesive, adhesive tape FLEX-DICHT For the insertion system, please comply with the module manufacturer s instructions.

24 IV. Flat Roof 1. Flat roof with low load capacity 1.1 TRI-STAND Aero for module widths mm and mm ballast shading angle ballast calculation as a function of the shading angle (Aero 80) 859 mm, (Aero 100) 1062 mm (Aero 80) 859 mm, (Aero 100) 1062 mm hexagonal screw M10x25 A2 hexagonal screw M10x25 A2 hammer head bolt M10x20 A2 hammer head bolt M10x20 A2 hammer head bolt M10x20 A2 No Regupol protective strips between module rows! Regupol protective strip Regupol protective strip up to max. 5 roof inclination with horizontal module installation with film cover or bitumen gravel-covered roofs or green roof areas Installation fast module installation with few components; yet more time-saving with preassembled supports no penetration of roof membrane possible module load of up to 5,400 N/m 2 manufacturer-conforming module installation at installation drill holes suitable for standard modules of a width of 790 to 820 mm and 990 to 1010 mm Ballast aerodynamically optimized for s with low load capacity flexible weighting on the rear by means of concrete slabs or flagstones reduced dynamic and wind pressure load by means of wind deflector UP-C connector TS-F angle wind deflector Regupol film profile for high static loads, required depending on design if necessary for the connection of continuous rails fixed 20 inclination for optimum shading clearance in two standard designs for optimum roof protection

25 IV. Flat Roof 1. Flat roof with low load capacity 1.2 TRI-STAND east/west support module clamp angle 10 mounting angle 10 angle 10 hammer-head bolt M10x20 A2 and self-locking nut M10 A2 hammer-head bolt M10x20 A2 and self-locking nut M10 A2 angle 10 support 10 module clamp Ballast for aluminium sheet Ex.: stone dimension 25 x 12,5 x 5, ca. 3,6 kg/stone 3 stones x 3,6 kg/stone = 10,8 kg Gravel roofs and green roof areas Trapezoidal sheet metal and standing seam roofs Installation clip system: Manufacturer-conforming module installation no penetration of roof membrane possible module load of up to 5,400 N/m 2 Ballast aerodynamically optimized for s with low load capacity flexible weighting on the rear by means of concrete slabs or flagstones profile for high static loads, required depending on design support angle 10 and 20 UP-TS profile for installation on trapezoidal sheet metal roof

26 IV. Flat Roof 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation Insertion system module mm mm module mm shading angle UP-L, UP or UP-S Renosol panels 800x600x35 roof areas with gravel, granulate, bitumen or film cover for additional module inclinations on pitched roofs with up to 20 roof pitch gravel-covered roofs or green roof areas Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

27 IV. Flat Roof 2. Flat roof with normal load capacity 2.1 TRI-STAND triangle installation Clip system module shading angle UP-L, UP or UP-S Renosol panel 800x600x35 roof areas with gravel, granulate, bitumen or film cover for additional module inclinations on pitched roofs with up to 20 roof pitch gravel-covered roofs or green roof areas Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market horizontal and vertical module installation flexible module inclinations (20 /30, ) for optimum yield depending on location excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof

28 IV. Flat Roof 2. Flat roof with normal load capacity 2.2 TRI-STAND upright installation Insertion system module mm mm module -575 mm shading angle Renosol panel 800x600x35 s with inclinations from -5 to +5 roof areas with gravel, granulate, bitumen or film cover for green roofs, uneven roofs and locations with heavy snowfall Insertion system time-saving no-screw module installation easy removal of modules for replacement or maintenance work no clip marks optimum load distribution Installation horizontal and vertical module installation flexible module inclinations (20 /30 ) for optimum yield depending on location large distance of modules to the roof, thus less shading excellent inherent stability TRI-DESIGN software for optimum, standard planning and dimensioning of the system profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

29 IV. Flat Roof 2. Flat roof with normal load capacity 2.2 TRI-STAND upright installation Clip system shading angle UP-L, UP or UP-S Renosol panel 800x600x35 s with inclinations from -5 to +5 roof areas with gravel, granulate, bitumen or film cover for green roofs, uneven roofs and locations with heavy snowfall Clip system materials-saving manufacturer-conforming mode of installation low system costs per kwp standard on the European market Installation horizontal and vertical module installation flexible module inclinations (20 /30 ) for optimum yield depending on location large distance of modules to the roof, thus less shading excellent inherent stability profile for high static loads, required depending on design TS profile insertion profile standard angle fixed support angle 20 or 30 SafeClick secure profile connection Renosol plates for fastening to the substructure on the roof

30 UP-L, UP or UP-S (length od module + 20) * number of modules - 20 (en mm) lenght of module length of module height of module field = (length of module insertion mm) * number of modules + 69 mm module mm module mm module mm UP-L, UP or UP-S V. FACADE 1. TRI-STAND vertical installation on s by means of hanger bolts directly on s by means of dowels or wood screws Module installation Insertion system: optimum load distribution and time-saving no-screw installation Clip system: materials-saving mode of installation and low system costs per kwp Facade Installation low module load (only wind pressure and suction) no plastering of s necessary developing new areas for PV systems UP universal UP-S universal UP-C universal profile UP-TS profile TS edging tool profile profile profile for high static loads secure connection of profiles with insertion systemm for SafeClick installation directly on building exterior for edge-trimming the profiles (insertion system) For the insertion system, please comply with the module manufacturer s instructions.

31 V. FACADE 2. TRI-STAND inclined installation anchoring forces AH, AV, BH and BV anchoring forces AH, AV, BH and BV vertical row spacing module mm mm module mm shading angle UP-L, UP or UP-S module inclincation length of horizontal support UP profile UP-S profile length of an individual wall rail clearance for individual wall rails length of an individual wall rail row spacing shading angle module inclincation UP-L, UP or UP-S UP profile length of horizontal support UP-L, UP or UP-S UP profile UP-S profile length of an individual wall rail length of an individual wall rail clearance for individual wall rails PV systems with canopy roof function Module installation on s by means of hanger bolts directly on s by means of dowels or wood screws Facade installation developing new areas for PV systems flexible angle of inclination (20 70 ) (insertion system) profile for high static loads, required depending on design TS profile insertion profile FlexFix angle freely selectable angle between 20 and 70 SafeClick secure profile connection TS edging tool for edge-trimming the profiles For the insertion system, please comply with the module manufacturer s instructions.

S:FLEX PRODUCTS Photovoltaic Mounting Systems. Product catalogue

S:FLEX PRODUCTS Photovoltaic Mounting Systems. Product catalogue Photovoltaic Mounting Systems Product catalogue S:FLEX PRODUCTS 2018 Premium s Proven Click Technology Precision without Cutting Pre-Assembled and Height-Adjustable Full Warranties and First-Class Service

More information

TRI STAND East-West for flat roofs

TRI STAND East-West for flat roofs TRI STAND East-West for flat roofs Energy for higher own consumption With TRI STAND East-West, TRITEC provides the ideal solution for PV systems with an east/west orientation. The advantage of these systems

More information

Schletter. Solar Mounting Systems

Schletter. Solar Mounting Systems Schletter Solar Mounting Systems Component Overview October 2016 Design, order, and purchase systems on-line! Ideally suited for projects of 50 kw or smaller in size, PV Powersite offers system configuration

More information

Installation Manual. Logasol SKS 4.0 Mounting on sloped roofs. Flat Plate Collectors. For Contractors. Please read carefully prior to installation.

Installation Manual. Logasol SKS 4.0 Mounting on sloped roofs. Flat Plate Collectors. For Contractors. Please read carefully prior to installation. Installation Manual Flat Plate Collectors 6706485.0-.SD Logasol SKS 4.0 Mounting on sloped roofs For Contractors Please read carefully prior to installation. 6 70 64 88-0/007 US Contents General information..........................................

More information

FKB-1 / FKC /200/300 l system. Thermosiphon for flat roofs and rooftops. Installation instructions (2010/06) GR

FKB-1 / FKC /200/300 l system. Thermosiphon for flat roofs and rooftops. Installation instructions (2010/06) GR 7 747 005 076.00-.RS Thermosiphon for flat roofs and rooftops FKB- / FKC- 50/00/00 l system Installation instructions 6 70 645 40 (00/06) GR Contents GR Contents Key to symbols and safety instructions........

More information

Mounting System Photovoltaic MSP system

Mounting System Photovoltaic MSP system Mounting System Photovoltaic MSP system Sector Application Product program Electro technology / Environmental technology Framework for photovoltaic systems for pitched roofs Mounting of framed photovoltaic

More information

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012 STANDING SEAM OVERVIEW SW-2 CB-2 CB-1 R-1 RK-1 V-1 SW-1 RK-1 H-1 VR-1 P-1 HW-1 PB-1 DE-2 DE-1 RK-3 DE-2 SP-1 OV-1 DRIP EDGE - 1 6" WIDE HIGH TEMP UNDERLAYMENT STRIP PRE-NOTCHED PANEL END STANDING SEAM

More information

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version Manual Mounting parallel bench srew mountingsystem Flate plate collector CPK 7210 N 6 9 0 x x x x / version 2008.03 Contents Safety information...3 Transport note...4 Assembly instructions - Collector...5

More information

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20 TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / M03-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective

More information

Installation and Operation Manual for a Solar System with KPW Collectors

Installation and Operation Manual for a Solar System with KPW Collectors Installation and Operation Manual for a Solar System with KPW Collectors EN v. 1.0 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting

More information

Installation instructions

Installation instructions Installation instructions Solar Collector 60966.0-.SD SKS.0 Series Flat Collector ON ROOF MOUNTING SOLAR THERMAL SYSTEMS For heating engineers Please read carefully prior to commissioning and maintenance

More information

Installation instructions

Installation instructions Installation instructions Solar Collector 60965.0-.SD SKN.0 Series Flat Collector ON ROOF MOUNTING Solar Thermal Systems For heating engineers Please read carefully prior to commissioning and maintenance

More information

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts...

PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3. GROUND and pole MOUNT SYSTEMS...5. L Feet...9. Corrugated/IBR Roof Mounts... S 1 Index PRODUCTS FOR PV SOLAR MOUNTING APPLICATIONS ROOF MOUNT SYSTEMS...3 GROUND and pole MOUNT SYSTEMS...5 Power Rail Module Mounting System...6 Power Rail Extrusions...7 Power Rail Commercial Extrusions...7

More information

VIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle

VIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle Installation instructions for contractors VIESMANN Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle VITOSOL 200-T 6/2010 Dispose after installation. Safety instructions Please

More information

Solar. Solar collectors

Solar. Solar collectors Solar Page Solar collectors Hoval UltraSol, UltraSol eco Description 267 Part No. 268 Technical data 295 Dimensions 302 Space requirements 305 Engineering 309 Examples 314 Product overview and utilisation

More information

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology 3.0 RAIL-FREE RACKING Utilizes EcoFasten Solar s patented technology Document Date: 05.08.2018 Contents Pg. 1... Assets of Design Features System Components Pg. 2... Rock-It 3.0 Mount Assembly Rock-It

More information

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology 4.0 RAIL-FREE RACKING Utilizes EcoFasten Solar s patented technology Document Date: 3.2.2018 Contents Pg. 1 Assets of Design Features System Components Pg. 2 Rock-It 4.0 Mount Assembly Rock-It 4.0 Coupling

More information

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM 42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,

More information

SOLAR-LIFESTYLE INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR FLAT ROOF AND WALL-MOUNTED INSTALLATION (2011/05) UK

SOLAR-LIFESTYLE INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR FLAT ROOF AND WALL-MOUNTED INSTALLATION (2011/05) UK INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR SOLAR-LIFESTYLE FLAT ROOF AND WALL-MOUNTED INSTALLATION 670647803-00.T 6 70 648 3 (0/05) UK TABLE OF CONTENTS TABLE OF CONTENTS Key to symbols

More information

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR ROOF MOUNTING INSTALLATION UK/IE (2011/05) GB/IE

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR ROOF MOUNTING INSTALLATION UK/IE (2011/05) GB/IE INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR SOLAR-LUX 6/ 6 70 646 03-00.0TL ROOF MOUNTING INSTALLATION UK/IE 6 70 647 040 (0/05) GB/IE TABLE OF CONTENTS TABLE OF CONTENTS Key to

More information

Pressure Sensitive Seam Tape Features 30.5m long rolls or sold by the metre (can be sold by 10th of metre). Must be used with an EPDM primer.

Pressure Sensitive Seam Tape Features 30.5m long rolls or sold by the metre (can be sold by 10th of metre). Must be used with an EPDM primer. 3 inch tape (75mm) Pressure Sensitive Seam Tape PS Seam Tape manufactured to precise width and thickness criteria with a clear poly backing for easier on site application. This Seam tape offers over 30%

More information

Bolt FBN The heavyweight.

Bolt FBN The heavyweight. 120 The heavyweight. OVERVIEW II, A4, stainless steel A4 Approved for: Non-cracked concrete C20/25 to C50/60 Also suitable for: Concrete C12/15 Natural stone with dense structure -GS (with large washer),

More information

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Conveyors slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer Application example conveyors Transport solutions and goods provision 1 2 3 4 5 6 7 8 362 9 1 slide strips Low-wear

More information

Component Catalogue Product Family SOE

Component Catalogue Product Family SOE 2013 Component Catalogue Product Family SOE solar@rybu.de RYBU GmbH 2012 Made in Germany Table of Contents Solar Racks 3-4 Roof Hooks 5 Base Trays 6-7 Base Rails 8 Braces 9-10 Clamps 11 Mounting Rails

More information

Installation and Operation Manual for a Solar System with KPC1-BP Collectors

Installation and Operation Manual for a Solar System with KPC1-BP Collectors Installation and Operation Manual for a Solar System with KPC1-BP Collectors EN v. 1.3 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting

More information

GUIDANCE NOTES. Solar Collectors. On-Roof Installation (First Fix) Please leave these instructions with the User. Baxi Heating UK Ltd 2012

GUIDANCE NOTES. Solar Collectors. On-Roof Installation (First Fix) Please leave these instructions with the User. Baxi Heating UK Ltd 2012 GUIDANCE NOTES Solar Collectors On-Roof Installation (First Fix) Baxi Heating UK Ltd 2012 Please leave these instructions with the User Contents 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 Symbols and tools 4

More information

L-SERIES CLUTCHES L-SERIES CLUTCHES. Getting Started INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

L-SERIES CLUTCHES L-SERIES CLUTCHES. Getting Started INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS L-SERIES CLUTCHES INSTALLATION INSTRUCTIONS Thank you for purchasing your new L-Series Clutches. They have been custom-made from the highest quality materials. to the dimensions you specified. With the

More information

SERIES W50 TECHNICAL CATALOGUE

SERIES W50 TECHNICAL CATALOGUE SERIES TECHNICAL CATALOGUE Heat-insulated building construction Series W 50 3 1 Catalogue cover 3 Catalogue pages Overview 4 Design Description 5 System Description 6 Installation Depths/Levels/Drainage

More information

MANUAL. Collector FK7300. Mounting parallel roof bracket attachment system

MANUAL. Collector FK7300. Mounting parallel roof bracket attachment system MANUAL Mounting parallel roof bracket attachment system For horizontal positioning of the collectors, the assembly instructions apply accordingly! Collector FK7300 6 9 0 x x x x / version 2006.12 Contents

More information

Fitting instructions for all. SitaAttika roof outlets and accessoires

Fitting instructions for all. SitaAttika roof outlets and accessoires s for all SitaAttika roof outlets and accessoires Contents General information 3 1. SitaTurbo Facade breakthrough.. 4 2. SitaTurbo Steam vapour barrier plate.. 5 3. SitaTurbo Steam vapour barrier flex..

More information

FS II - Mounting Instruction. 1 General 2. 2 Pile driving (Ramming) 3. 3 Mounting individual assemblies 4. 4 Components list 5

FS II - Mounting Instruction. 1 General 2. 2 Pile driving (Ramming) 3. 3 Mounting individual assemblies 4. 4 Components list 5 FS II Mounting Instruction CONTENTS Page 1 General 2 2 Pile driving (Ramming) 3 3 Mounting individual assemblies 4 4 Components list 5 5 Torque specifications 9 6 Module mounting 9 7 Cable mounting 10

More information

argco.com

argco.com 800-854-1015 argco.com STRUT SUPORT SYSTEM STRUT SUPPORT CHANNEL US Strut Support Channel Quick, strong attachment of single or multiple pipes horizontally or vertically Unlimited applications - range

More information

Commercial Hopper Tanks (CHT)

Commercial Hopper Tanks (CHT) Commercial Hopper Tanks (CHT) Total Value. Total Systems. NCHT & FCHT Series The right tank for the right job. Commercial hopper tanks are typically used in applications where routine clean out is required,

More information

Installation, operating and maintenance instructions

Installation, operating and maintenance instructions Installation, operating and maintenance instructions High performance solar collector TopSon F3-1 / F3-1Q / F3-Q Roof top installation with AluPlus installation system Single-row roof integration P 9 Wolf

More information

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL Masport Limited 1-37 Mt Wellington Highway Panmure Auckland 6 Ph: 09 571 1200 Fax: 09 571 5864 www.masport.com 2005 CONTENTS Ordering Information... Page 3 Freestanding

More information

for Solar Systems with KTU R Collectors

for Solar Systems with KTU R Collectors Installation and Operation Manual for Solar Systems with KTU R Collectors EN v. 1.7 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data... 4 1. Mounting System Delivery...

More information

Mounting System Photovoltaic MSP system

Mounting System Photovoltaic MSP system Mounting System Photovoltaic MSP system Sector Application Product program Electro technology / Environmental technology Framework for photovoltaic systems for pitched roofs Mounting of framed photovoltaic

More information

Play it safe. Mounting instructions incell system. Premium incell XM, L Mounting system for roof-integrated photovoltaic systems

Play it safe. Mounting instructions incell system. Premium incell XM, L Mounting system for roof-integrated photovoltaic systems Play it safe Mounting instructions incell system Premium incell XM, L Mounting system for roof-integrated photovoltaic systems DIN EN ISO 9001 Quality Management System DIN EN ISO 14001 Environmental Management

More information

REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS EFFICIENCY

REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS EFFICIENCY REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS INNOVATION SAFETY w w w.b l u ek i t.eu EFFICIENCY The ventilation components constitute a key factor for ventilation

More information

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class.

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class. 118 FAZ II Millionfold proven bolt and the strongest in its class. OVERVIEW FAZ II, zinc-plated steel FAZ II A4, stainless steel of the corrosion resistance class III, e.g. A4 FAZ II C, highly corrosion-resistant

More information

Installation. Storage. Tools

Installation. Storage. Tools Contents Page Installation, Storage, Tools 2 Safety Tips, Maintenance, Important Notice... 3 Direction of Application.. 4 Installation Details Overview. 5 Eave and Gable Details. 6 Wall Flashing Details..

More information

SHELVING PRODUCTS. Maximize Your Storage Space

SHELVING PRODUCTS. Maximize Your Storage Space SHELVING PRODUCTS Maximize Your Storage Space SHELVING UNITS Pre-engineered sections are 36, 42, and 48 wide and 84, 96 and 120 high, with shelves adjustable on 1-1/2 centers. For double row, back-to-back

More information

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM 42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,

More information

Flat-roof system Windsafe

Flat-roof system Windsafe Flat-roof system Windsafe Modular systems optimized for superimposed loads CONTENTS PAGE 1 General information 2 2 Planning 2 3 Article overview 3 4 Mounting of supports 6 5 Exploded view 7 6 Tolerances

More information

PV-ezRack SolarTerrace III-A Installation Guide V1.4

PV-ezRack SolarTerrace III-A Installation Guide V1.4 PV-ezRack SolarTerrace III-A Installation Guide V1.4 CONTENT 1. Introduction...2 2. Tools & Components...3 3. Installation Guide. 8 4. Service..15 Clenergy Australia 1/10 Duerdin St, Clayton VIC 3168 T:

More information

MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM 42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product

More information

VIESMANN. Installation instructions VITOSOL 300-T. for contractors. Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle

VIESMANN. Installation instructions VITOSOL 300-T. for contractors. Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle Installation instructions for contractors VIESMANN Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle VITOSOL 300-T 9/2009 Dispose after installation. Safety instructions Please

More information

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64)

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64) 64 Glass, Window regulators (Page GR-64) Flush bonded windows Body flange, preparing for glass installation Broken rear window, removing Cleaning off excess adhesive material Curing time Installation instructions

More information

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS PO Box 7000 Carlisle, PA 17013 800-211-7170 MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS 07319.1 Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3

More information

Operations and Assembly Manual

Operations and Assembly Manual Operations and Assembly Manual Betriebs- und Montageanleitung Assembly-Ready Montagefertige Solar Solarabsorber Absorber Solar Units Solar Units Solar Units Ice Rinks Ice Rink Rental Congratulations on

More information

LYSAGHT SELECT SEAM Series

LYSAGHT SELECT SEAM Series LYSAGHT SELECT SEAM Series St. Theresa s Church Market and Food Centre at Bedok Reservoir Road Residential project at Ripley Crescent LYSAGHT SELECT SEAM SERIES ROOF PROFILE Sleek and aesthetically pleasing

More information

fischer Bolt anchor FAZ II

fischer Bolt anchor FAZ II fischer Bolt anchor FAZ II The power anchor for highest demands NEW Bolt anchor FAZ II For highest demands Powerful and flexible The distinctive edge holds the expansion clip in position even with reinforcement

More information

Current Automation Catalogue Page 219. Fronius

Current Automation Catalogue Page 219. Fronius Current Automation Catalogue Page 219 Fronius SMA Visit our website for more indebt info on this product range Current Automation Catalogue Page 220 SMA SW - 50 SW - 80 SW - 130 / 140 SW - 230-250 Warrenty

More information

2002 Convertible Cloth Sleeve Convertible Cloth Attachment

2002 Convertible Cloth Sleeve Convertible Cloth Attachment 2002 Glass Convertible Top on 2000-2001 Frame Submitted by Clovis, North Texas S2000 Owners Club So what s the difference? Honestly, not much. The 2000 soft top cloth has attachment points for each of

More information

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology 2.0 RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Document date 3.6.2017 Contents Pg. 1 Assets of Design Features System Components Pg. 2 Rock-It 2.0 Mount Assembly Rock-It

More information

Installation Lexan Panel Pulley Driven Lifting System

Installation Lexan Panel Pulley Driven Lifting System Installation Lexan Panel Pulley Driven Lifting System Ventilation Secco division of Secco International inc. 4040 blvd. Casavant West St-Hyacinthe, Qc J2S 8E3 T: 450-771-0777 F: 450-771-5779 secco@seccointernational.com

More information

Sunroof / Moonroof: Service and Repair Repair Procedures

Sunroof / Moonroof: Service and Repair Repair Procedures 2011 Kia Truck Sportage 2WD L4-2.4L Copyright 2013, ALLDATA 10.52 Page 1 Sunroof / Moonroof: Service and Repair Repair Procedures Replacement Movable Glass Replacement 1. Remove the roof rack and roof

More information

Installation Instructions

Installation Instructions Tile Integrated Mounting System Installation Instructions This document describes basic installation procedures for Zep Solar s tile-integrated mounting system for use with Zep Compatible PV modules installed

More information

THE NEW TS IT RACK 8

THE NEW TS IT RACK 8 THE NEW TS IT RACK 8 Fast and reliable Fast Loosen the 48. (9 ) quickrelease fastener, slide into the correct position, and latch Reliable Maximum load capacity up to,000 N Convenience in perfection Interior

More information

VIESMANN. Installation instructions VITOSOL-F. for contractors

VIESMANN. Installation instructions VITOSOL-F. for contractors Installation instructions for contractors VIESMANN Vitosol-F Type SV and SH Flat-plate collector for installation on supports and wall mounting VITOSOL-F 9/2010 Dispose after installation. Safety instructions

More information

Components, Mounting Systems, In-roof PV Solutions FATH Solar About us Page 3

Components, Mounting Systems, In-roof PV Solutions FATH Solar About us Page 3 Important matters Brochure Content Components, Mounting Systems, In-roof PV Solutions FATH About us Page 3 S1 System S1: Half as Complex and Twice as Safe Page 4 S1: Pivotal Advantage for all Standard

More information

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with

More information

The GK units differ from the LK units in that the springs of the GK units have a spring eye at the front.

The GK units differ from the LK units in that the springs of the GK units have a spring eye at the front. 01 09 Installation guidelines Mechanical suspension units GK LK GN0032-0 Mechanical suspension units GK LK The GK units differ from the LK units in that the springs of the GK units have a spring eye at

More information

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems

Befestigungssysteme Klimatechnisches Zubehör. Fixing systems Befestigungssysteme Klimatechnisches Zubehör Fixing systems With us, insulation work becomes enjoyable For almost three decades, we have been a leading enterprise in innovative systems for technical insulation

More information

5 Mechanisms and accessories

5 Mechanisms and accessories 5 Mechanisms and accessories 51A SIDE OPENING ELEMENT MECHANISMS 52A NON-SIDE OPENING ELEMENT MECHANISMS 54A WINDOWS 55A EXTERIOR PROTECTION 56A EXTERIOR EQUIPMENT 57A INTERIOR EQUIPMENT 59A SAFETY ACCESSORIES

More information

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM 42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,

More information

Introduction to Solar PV. Basics

Introduction to Solar PV. Basics Introduction to Solar PV Basics Solar PV Introduction 1. Solar PV Theory a) Photoelectric Effect b) What is a Solar Cell c) How do Solar Panels work d) What are solar panel basic components e) Types of

More information

access

access 184 Table of Contents Access Garage door Motors Dexxo Pro 800 RTS... 188 Dexxo Pro 1000 RTS... 189 Dexxo Optimo RTS... 190 Receiver Axroll NS... 191 Freeroll ESE RTS, RTS receiver for roller garage doors...

More information

KROFTMAN CONTAINER SHELTER TC812

KROFTMAN CONTAINER SHELTER TC812 KROFTMAN CONTAINER SHELTER CONTENT FRAME P82-FR 82-0 82-02 82-03 82-0 82-05 82-06 82-07 parts list frame part numbers main frame base plan, frame plan available hight inside detail 0 detail 02, 03 Roof

More information

insulated sectional 2180mm (h) x 2550mm (w) Opening Size: 2140mm (h) x 2500mm (w) suits single car garage

insulated sectional 2180mm (h) x 2550mm (w) Opening Size: 2140mm (h) x 2500mm (w) suits single car garage insulated sectional Garage Door 2180mm (h) x 2550mm (w) Opening Size: 2140mm (h) x 2500mm (w) suits single car garage Disclaimer This product should be installed by a competent person or suitably qualified

More information

MÜPRO. One-piece pipe clamps. Sprinkler pipe clamps. Refrigerant pipe clamps. Two-piece pipe clamps. Heavy-duty pipe support/din pipe clamps

MÜPRO. One-piece pipe clamps. Sprinkler pipe clamps. Refrigerant pipe clamps. Two-piece pipe clamps. Heavy-duty pipe support/din pipe clamps 0. MÜPRO 1. Vibration control 2. Fire protection 3. Pipe clamps 4. Support channels 5. Accessories 6. Anchor points/expansion points 7. Heavy-duty pipe support 8. MPT-Support system 9. Ventilation 10.

More information

METAL BUILDING AND STANDING SEAM COMPONENTS

METAL BUILDING AND STANDING SEAM COMPONENTS METAL BUILDING AND STANDING SEAM COMPONENTS COMMERCIAL AND INDUSTRIAL KENTUCKY ILLINOIS 925 Rolling Hills Ln. 1181 S.R. 121 Winchester, KY 40391 Mt. Zion, IL 62549 TEL: 859-744-4475 TEL: 217-864-5835 FAX:

More information

3-Phase Motor Demo. R Hoadley 10 Oct 2009

3-Phase Motor Demo. R Hoadley  10 Oct 2009 3-Phase Motor Demo R Hoadley www.coolmagnetman.com 10 Oct 2009 1 Basic Layout 2 3 4 Each Electromagnet 5 Each Electromagnet The electromagnets I had were: About ¾ diameter core About 1-3/16 long About

More information

Tecstrut Channel Suspension & Framing System

Tecstrut Channel Suspension & Framing System lindab I the ventilation products specialist Tecstrut Channel Suspension & Framing System Complies with HVCA specification DW144. Manufactured from corrosion resistant materials. Channels produced in accordance

More information

EN Vario Curtain Sider Roof. Assembly instructions.

EN Vario Curtain Sider Roof. Assembly instructions. EN 2016 07 Vario Curtain Sider Roof Assembly instructions Contents? Operation 3 Inserting sliding pillars 36 Hook in sliding pillars 37 Installing batten pockets 38 Designated use 4 Installing battens

More information

PV on flatroofs - fast and easy. made in Germany

PV on flatroofs - fast and easy. made in Germany PV on flatroofs - fast and easy made in Germany The beginning The KNUBIX-company was founded by Markus Michelberger in 2008. He was searching for a solution to use flatroofs for efficient energyproduction

More information

Cordless rotary hammer drill 18,0 V CHE 18.0-EC

Cordless rotary hammer drill 18,0 V CHE 18.0-EC Bahnhofstraße 5 77 Steinheim Phone +49 744 828-0 Fax +49 744 25899 Cordless rotary hammer drill 8,0 V CHE 8.0-EC Order number 430.005 Battery voltage 8 V Battery capacity 2,5 / 5,0 Ah No load speed 0-400

More information

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989 STATE OF NORTH CAROLINA 7125-2D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION Superseding 7125-LM-2C November 9, 1989 SPECIFICATION FOR LOCKERS, METAL (This specification is

More information

NEW RESIDENCE - Sample Takeoff UpState Estimating / Material Takeoff

NEW RESIDENCE - Sample Takeoff UpState Estimating /   Material Takeoff NEW RESIDENCE - Sample Takeoff UpState Estimating / www.upstateestimating.com Material Takeoff _NOTES Floor System By Others Roof System-Stick Built... Verify Header/Beam Sizes... Verify Ridge-Hip-Valley

More information

The specialist for fastening technology. Post holders NEW. to our product range

The specialist for fastening technology. Post holders NEW. to our product range Post holders H post anchors H post anchors Fork width Dimensions a) Drill holes b) Art. no. (mm) Overall/Post support (mm) Post support (mm) PU 904722 91 600 x 60 / 300 4 x 11 904723 101 600 x 60 / 300

More information

Modul-System SMART AND VERSATILE MULTI-BOX

Modul-System SMART AND VERSATILE MULTI-BOX Modul-System SMART AND VERSATILE MULTI-BOX The Smart Multi-Purpose Tool Box Robust and ergonomic tool and storage box Easy to transport and take to any place of work Attractive design and smart functionality

More information

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877) By CNP INDUSTRIES, INC. P.O. Box 8645 Anaheim, Ca 987 (877) 387-67 VENTILATOR VEN50/VEN00 INSTALLATION INSTRUCTIONS Ventilator Can Be Used For Roof or Wall Mounting Recommended for use over household gas

More information

BAVONA TP6500 HARDTOP

BAVONA TP6500 HARDTOP VON HRTOP eschreibung escription min. 200 cm max. 600 cm 0 min. 200 cm max. 600 cm Terrace pavilions comprising a continuous cubic frame (extruded aluminium profile dimension 230 x mm) and a lamella canopy.

More information

technical sheet RAILSCAF horizontal monorail access system

technical sheet RAILSCAF horizontal monorail access system Railscaf horizontal monorail access system ref.: T-529 rev. no.: 2 date: 0/98 page: /8. GENERAL The is a building maintenance system comprising a monorail fixed around the perimeter of a building or structure.

More information

Function: Used to connect profiles at adjustable angles. Features: 1. Adjustable angles. Item Description For Screw Weight (g) Colour Finish Material

Function: Used to connect profiles at adjustable angles. Features: 1. Adjustable angles. Item Description For Screw Weight (g) Colour Finish Material 4.56 Swivel Fastener (SWF): Function: Used to connect profiles at adjustable angles. 1. Adjustable angles. SWF 1.25.0132.0 8 M6x S3.60 M6 S3.61 M6x S3.60 Item Description For Screw Weight (g) Colour Finish

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. THIRD-ROW P/N 08R12-SHJ-100 2008 ODYSSEY AII 38141 Issue Date OCT 2007 PARTS LIST Left rear sunshade Driver s Side 1. Remove the spare tire

More information

Sunbeam Nova. Installation guide. Universal. Symmetrical THE PROFESSIONAL PV MOUNTING SYSTEM

Sunbeam Nova. Installation guide. Universal. Symmetrical THE PROFESSIONAL PV MOUNTING SYSTEM THE PROFEIONAL PV MONTING YTEM Installation guide unbeam Nova niversal Page 4-5: : installation of a unbeam niversal system (solar panels facing south). ymmetrical Page 6-7: installation of a unbeam ymmetrical

More information

INSTALLATION FIXED CANVAS TS100 PULLEY DRIVEN LIFTING SYSTEM

INSTALLATION FIXED CANVAS TS100 PULLEY DRIVEN LIFTING SYSTEM INSTALLATION FIXED CANVAS TS100 PULLEY DRIVEN LIFTING SYSTEM Ventilation Secco division of Secco International inc. 4040 blvd. Casavant West St-Hyacinthe, Qc J2S 8E3 T: 450-771-0777 F: 450-771-5779 secco@seccointernational.com

More information

Cordless angle grinder ACCUFLEX 18.0 V, 125 mm. L EC/5.0 Set

Cordless angle grinder ACCUFLEX 18.0 V, 125 mm. L EC/5.0 Set Bahnhofstraße 5 77 Steinheim Phone +49 744 828-0 Fax +49 744 25899 Cordless angle grinder ACCUFLEX 8.0 V, 25 mm L 25 8.0-EC/5.0 Set Order number 47.947 Battery voltage 8 V Battery capacity 2,5 / 5,0 Ah

More information

TRIC A On-Roof Installation for EURO- Collectors*

TRIC A On-Roof Installation for EURO- Collectors* INSTALLATION INSTRUCTIONS TRIC A On-Roof Installation for EURO- Collectors* Fig. 1 Vertical and horizontal on-roof (roof parallel) installation examples Content 1 General Safety Notes. Horizontal Installation.

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

Original operating instructions. Transit silo. Model. Transit silo

Original operating instructions. Transit silo. Model. Transit silo Original operating instructions Transit silo Model Transit silo Ambros Schmelzer & Sohn GmbH & Co KG Dr.-Zimmer-Str. 28, 95679 Waldershof Telefon 0923-9792-0 Fax 09231-972697 E-Mail info@a-schmelzer.de

More information

Slim profile steel system for doors and windows

Slim profile steel system for doors and windows Slim profile steel system for doors and windows 2 TABS thermal insulation system 3 Window and door variants 5 References 15 Overview of products and items 39 The latest information and technical descriptions

More information

PATIO AWNINGS HAROL VZ520 TECHNICAL INFORMATION

PATIO AWNINGS HAROL VZ520 TECHNICAL INFORMATION Page 2 Exploded View VZ520 VZ520 TECHNICAL DATA PATIO AWNINGS HAROL VZ520 Intermediate roller support VZ520 TECHNICAL INFORMATION www.aalta.com.au T 61 02 8065 4911 E info@aalta.com.au A 47A Pine Street,

More information

Bolter Miner ABM Technical Description

Bolter Miner ABM Technical Description Bolter Miner -016 Bolter Miner -016 TABLE OF CONTENTS 1 TECHNICAL DESCRIPTION 1.1 General 1. Technical data 3 1.3 Dimensions of the machine 6 1.4 Cutter head profile 6 MACHINE CONCEPT - MAJOR COMPONENTS

More information

Guangzhou Stadium Project TRADITIONAL

Guangzhou Stadium Project TRADITIONAL ject Pro um i d a t ou S ngzh Gua Traditional Danpalon Multicell provides exceptional quality of light, a rich non-industrial visual appeal and delivers superior durability, thermal insulation and 99.9%

More information

SKYFORCE. Max. width up to 3000 mm Suitable for plastic, aluminium and wooden frames Mounting on stone, concrete and steel

SKYFORCE. Max. width up to 3000 mm Suitable for plastic, aluminium and wooden frames Mounting on stone, concrete and steel SKYFORCE Quick and simple mounting Different surface finishes Available for different glass thicknesses, pre-assembled as set Max. width up to 3000 mm Suitable for plastic, aluminium and wooden frames

More information

9'8" x 9'8" (8,8 m2)

9'8 x 9'8 (8,8 m2) 9'8" x 9'8" (8,8 m) 007-CH 007 - CH GB May we congratulate you on your new greenhouse US Dear DER Customer! CUSTOMER The Congratulations assembly of on your purchasing new house your new requires greenhouse.

More information

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET Please contact the Techline for the most current instruction information (800) FORD788.!!! PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION!!! OVERVIEW: The use of a floor hoist is

More information

UniRac. 28 MOUNTING STRUCTURES Roof Mounts. SolarMount

UniRac. 28 MOUNTING STRUCTURES Roof Mounts. SolarMount 28 MOUNTING STRUCTURES Roof Mounts SolarMount s SolarMount is a fast, easy, safe way to install a PV array in virtually any roof or ground installation. Bottom mounting clips and tilt legs supplement traditional

More information