REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS EFFICIENCY

Size: px
Start display at page:

Download "REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS EFFICIENCY"

Transcription

1 REGULATED VENTILATION FOR LIFT SHAFTS SIMPLE AND EFFICIENT BLUEKIT VENTILATION FLAPS INNOVATION SAFETY w w w.b l u ek i t.eu EFFICIENCY

2 The ventilation components constitute a key factor for ventilation regulation and optimization. They are crucial for the execution of an efficient energetic concept and contribute to the decrease of building operating costs. It is possible to combine our BlueKit system with louvre windows or ventilation flaps which are in accordance with EN , together or without protection accessories such as weather protection grilles or roof vents. HORIZONTAL MOUNTING in the shaft head/on the roof VERTICAL MOUNTING in the shaft/on the facade Abbreviations: - HV: Horizontal vertical - TF: Thermo Flap - LF: Louvre window - S: Sheet steel - A: Aluminum

3 Contents Horizontal mounting Ventilation flap JK-180 HV... 4 Ventilation flap JK-180 HV-dB... 6 Roof vent JK-180 HVC... 8 Roof vent with blades JK-180 HVL Insulated roof vent TF (Thermo Flap) Vertical mounting Ventilation flap with weather protection grille JK-180 HV ALAS Insulated louvre windows S9-iVt-05 LF-MR Tairmo-LF-MR Modernisation Horizontal and vertical mounting Ventilation flap JK Ventilation flap JK-190-dB Horizontal mounting JK-190 ceiling-corner mounting (accessories)... 22

4 Ventilation flap JK-180 HV Description Smoke and heat exhaust ventilation (SHEV) device allowing a flush-mounted closure of the permanent lift shaft opening. The flap is designed for a horizontal and integrated installation inside the opening. The flap s spring return motor ensures its opening in case of power failure. Characteristics Flush installation Easy connection to exterior ventilation shaft Possible combination with roof vent Easy installing, easy access to motor Louvres made of aluminum profile, streamlined and torsion-resistant Delivered and assembled with profiled mounting plate Pre-assembled and pre-cabled motor Motor cabling with RJ45 connector for easy connection to BlueKit system Motor with positive safety function in case of power failure The most efficient solution for new buildings Spring return motor certified according to: EN Supplementary products Sealing tape expanding, used for sealing between the ventilation flap and shaft wall (included in the mounting set) Technical specification JK-180 HV Louvres Aluminium Seals EPDM-rubber Material Profiled sheet steel, dimensionally stable Thickness 1,5 mm Spring return motor Power supply 24 VAC/DC Torque 20 Nm Functional safety cycles (EN certification) Service life emergency positions (manufacturer specifications) Run-time Sound power level Closing via motor 150 sec. Opening via spring return 20 sec. Closing via motor 40 db Opening via spring return 62 db 4 BlueKit ventilation flaps - September 2017

5 Ventilation flap JK-180 HV MOUNTING FROM THE ROOF* Section B-B Section A-A MOUNTING FROM THE SHAFT Section B-B Section A-A Spring return motor dimensions Articles and dimensions - JK-180 HV Designation acc. to flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,41 0,62 0,90 1,22 Recommended opening dimensions (mm) B1xH1 590x x x x x x1290 Minimal opening dimensions (mm) B1xH1** 530x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 Article number Other dimensions available upon request ** When using the minimal opening, dimensions demounting of the flap is necessary for the maintenance or replacement of the motor. Application For installation from the shaft, the RJ45 connection cable is placed on the shaft side and tightened through the cable joint in order to guarantee airtightness. The sealing tape is then attached on the edge of the mounting plate which faces the wall. Finally, the ventilation flap is placed in the opening and fixed through the drilling holes of the mounting plate with wall anchors. * Depending on the installation position, the maintenance of the flap might have to occur on the roof. By way of precaution we point out that applicable accident prevention regulations must be observed. September BlueKit ventilation flaps 5

6 Ventilation flap JK-180 HV-dB Description Smoke and heat exhaust ventilation (SHEV) device allowing a flush-mounted closure of the permanent lift shaft opening. The flap is designed for a horizontal and integrated installation inside the opening. The flap is equipped with a low-noise direct current motor. Characteristics Easy connection to exterior ventilation shaft Possible combination with roof vent Easy installation, easy access to motor Louvres made of aluminum profile, streamlined and torsion-resistant Delivered and assembled with profiled mounting plate Pre-assembled and pre-cabled motor Motor cabling with RJ45 connector for easy connection to BlueKit system Low-noise direct current motor Low noise level Direct current motor certified according to: EN Supplementary products Sealing tape expanding, used for sealing between the ventilation flap and shaft wall (included in the mounting set) 6 Technical specification Louvres Seals Material Thickness Power supply Torque Functional safety Run-time Sound power level JK-180 HV-dB Aluminium EPDM-rubber Profiled sheet steel, dimensionally stable 1,5 mm Direct current motor 24 VDC 10 Nm cycles (EN certification) ca. 4 sec. ca. 25 db BlueKit ventilation flaps - September 2017

7 Ventilation flap JK-180 HV-dB MOUNTING FROM THE ROOF* Section B-B Section A-A MOUNTING FROM THE SHAFT Section B-B Section A-A Direct current motor dimensions Articles and dimensions - JK-180 HV-dB Designation acc. to flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,41 0,62 0,90 1,22 Recommended opening dimensions (mm) B1xH1 590x x x x x x1290 Minimal opening dimensions (mm) B1xH1** x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 Article number Other dimensions available upon request ** When using the minimal opening, dimensions demounting of the flap is necessary for the maintenance or replacement of the motor. Application For installation from the shaft, the RJ45 connection cable is placed on the shaft side and tightened through the cable joint in order to guarantee airtightness. The sealing tape is then attached on the edge of the mounting plate which faces the wall. Finally, the ventilation flap is placed in the opening and fixed through the drilling holes of the mounting plate with wall anchors. * Depending on the installation position, the maintenance of the flap might have to occur on the roof. By way of precaution we point out that applicable accident prevention regulations must be observed. September BlueKit ventilation flaps 7

8 Roof vent JK-180 HVC Description Ventilation flap and roof vent hood for horizontal mounting on flat roofs. The hood is composed of a base and a removable cover. The base is adapted to the ventilation flap where both elements are connected. The hood guarantees absolute rain protection - even in opened position of the flap. The ventilation and smoke extraction are assured in case of high wind speeds regardless of the weather and wind direction. Characteristics Ventilation flap JK-180 HV or JK-180 HV-dB (see specifications of JK-180 HV/JK-180 HV-dB) Flat roof base with connection interface for the ventilation flap Flexible mounting of the flap: flush-mounted from inside the shaft or inside of the base Integration to thermal insulation Weather protection Condensate recovery gutter and outlet nozzle Eased maintenance thanks to the good accessibility when removing the cover Bird protection grille inside the hood s: spring return or low-noise direct current motor (ref....-db...); roof vent hood made of galvanized steel (Ref....-S) or aluminium (ref....-a) Optimal protection under all weather conditions Base and cover available in numerous RAL colours Technical specification The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional s tasks. Depending on the installation position, the maintenance of the flap might have to occur on the roof. By way of precaution we point out that applicable accident prevention regulations must be observed. certified according to: EN Material JK-180 HVC Galvanized steel (ref....-s) Aluminium (ref....-a) Base wall thickness Base structure - 1,2 mm Flange - 2 mm Cover wall thickness Inner body - 2 mm Exterior sheet - 1,2 mm Finishing Base - spot welding Cover - riveting BlueKit ventilation flaps - September 2017

9 Roof vent JK-180 HVC Section B-B Section A-A Condensate outlet nozzle Flat roof upper layer Roof sealing Thermal insulation Concret ceiling Articles and dimensions - JK-180 HVC Designation acc. to flap opening (mm) BxH Net ventilation surface (m2) Recommended opening dimensions (mm) B1xH1 Minimal opening dimensions (mm) B1xH1* Mounting plate dimensions (mm) B2xH2 Cover dimensions B3xH3 Base height (mm) L1** Cover height (mm) L2 Overall height of the roof vent (mm) L3 Article number JK-180 HVC-S Article number JK-180 HVC-S-dB Article number JK-180 HVC-A Article number JK-180 HVC-A-dB 360x360 0,10 590x x x x x530 0,23 760x x x x x700 0,41 930x x x x x860 0, x x x x x1030 0, x x x x x1200 1, x x x x Application For installation from the roof, the flap is placed in the roof opening. The base is put on the mounting plate of the flap so that the drilling holes match and is then fixed on the ceiling with wall anchors. Finally, the weather cover is screwed on the base. Please refer to the BlueKit L-AIO installation guide for further installation details. * When using the minimal opening dimensions, demounting of the flap is necessary for the maintenance or replacement of the motor. See also JK-180 HV-dB for the minimal opening dimensions of JK-180 HVC-S-dB ** other base heights available upon request September BlueKit ventilation flaps 9

10 Roof vent with blades JK-180 HVL Description Ventilation flap and roof vent hood with blade for horizontal mounting on flat roofs. The hood is composed of a base and a removable cover. The base is adapted to the ventilation flap where both elements are connected. The hood guarantees an absolute rain protection - even in opened position of the flap. The ventilation and smoke extraction are assured in case of high wind speeds regardless of the weather and wind direction. Characteristics Ventilation flap JK-180 HV or JK-180 HV-dB (see specifications of JK-180 HV/JK-180 HV-dB) Flat roof base with connection interface for the ventilation flap Flexible mounting of the flap: flush-mounted from inside the shaft or inside of the base Integration to thermal insulation Weather protection Ideal for lack of space: the cover dimensions correspond to the base dimensions Condensate recovery gutter and outlet nozzle Eased maintenance thanks to the good accessibility when removing the cover Bird protection grille inside the hood s: spring return or low-noise direct current motor (ref....-db...); roof vent hood made of galvanized steel (Ref....-S) or aluminium (ref....-a) Compact solution for optimal insulation and protection Base and cover available in numerous RAL colours Technical specification The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional s tasks. Depending on the installation position, the maintenance of the flap might have to occur on the roof. By way of precaution we point out that applicable accident prevention regulations must be observed. certified according to: EN Material JK-180 HVL Galvanized steel (ref....-s) Aluminium (ref....-a) Base wall thickness Base structure - 1,2 mm Flange - 2 mm Cover wall thickness Inner body - 2 mm Exterior sheet - 1,2 mm Finishing Base - spot welding Cover - riveting BlueKit ventilation flaps - September 2017

11 Roof vent with blades JK-180 HVL Section B-B Section A-A Condensate outlet nozzle Flat roof upper layer Roof sealing Thermal insulation Articles and dimensions - JK-180 HVL Designation acc. to flap opening (mm) BxH Net ventilation surface (m2) Recommended opening dimensions (mm) B1xH1 Minimal opening dimensions (mm) B1xH1* Mounting plate dimensions (mm) B2xH2 Cover dimensions B3xH3 Base height (mm) L1** Cover height (mm) L2 Overall height of the roof vent (mm) L3 Article number JK-180 HVL-S Article number JK-180 HVL-S-dB Article number JK-180 HVL-A Article number JK-180 HVL-A-dB 360x360 0,10 590x x x x x530 0,23 760x x x x x700 0,41 930x x x x x860 0, x x x x x1030 0, x x x x x1200 1, x x x x Application For installation from the roof, the flap is placed in the roof opening. The base is put on the mounting plate of the flap so that the drilling holes match and is then fixed on the ceiling with wall anchors. Finally, the weather cover is screwed on the base. Please refer to the BlueKit L-AIO installation guide for further installation details. * When using the minimal opening, dimensions demounting of the flap is necessary for the maintenance or replacement of the motor. See also JK-180 HV-dB for the minimal opening dimensions of JK-180 HVL-S-dB ** other base heights available upon request September BlueKit ventilation flaps 11

12 Insulated roof vent TF (Thermo Flap) Description Thermally insulated smoke and heat exhaust ventilation (SHEV) hood for horizontal mounting on flat roofs (max. slope up to 5%). For ventilation and smoke exhaust purposes the hood is equipped with an 24V electric motor. Ready-to-install solution composed of a base in fiberglass, an integrated motor-driven louvre window with thermally separated aluminium profiles and a cover. Characteristics Integration to thermal insulation Weather protection Ready-to-install solution Fall-through-resistant Ventilation and smoke extraction through ventilation opening on 4 sides assured regardless of wind direction The insulated base in fiberglass (GRP) prevents from condensate formation Eased maintenance thanks to the good accessibility when removing the cover Insect protection grille inside the cover Excellent heat transfer coefficient: 0,41-0,55 W/m2k Ideal for lack of space: the cover dimensions correspond to the base dimensions The all-in-one solution with insulation Insect protection grille Technical specification Louvre window Base certified according to: EN Cover Power supply Torque Functional safety Run-time Sound power level TF 1,5 mm aluminium sheet on both sides 25 mm PU foam insulation inside 2,5 mm GRP layer on both sides, Foam insulation inside - Overall thickness 60 mm 0,8 mm galvanized steel sheet Direct current motor 24 VDC 10 Nm cycles ca. 4 sec. ca. 25 db BlueKit ventilation flaps - September 2017

13 Insulated roof vent TF (Thermo Flap) Section B-B Section A-A 450x450mm - 1 blade 600x600mm - 2 blades Flat roof upper layer Roof sealing Thermal Insulation 800x800mm - 3 blades Articles and dimensions - TF Designation acc. to opening dimensions (mm) BxH Net ventilation surface (m2) Base dimensions (mm) B1xH1 Cover dimensions (mm) B2xH2 Base height (mm) L1 Cover height (mm) L2 Overall height (mm) L3 U-Value (W/m2K) Number of blades Weight (kg) Article number TF 450x450 0,10 810x x , x600 0,20 960x x , x800 0, x x , Application The low weight allows a simple handling and positioning on the roof. No special substructure or mounting is required: the hood is preassembled and is fixed directly above the opening with stainless steel screws. The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional s tasks. Depending on the installation position, the maintenance of the flap might have to occur on the roof. By way of precaution we point out that applicable accident prevention regulations must be observed. September BlueKit ventilation flaps 13

14 Ventilation flap with weather protection grille JK-180 HV-ALAS Description Ventilation flap and weather protection grille allowing a flush-mounted closure of the permanent lift shaft opening. The flap is designed for a vertical and integrated installation inside the facade opening. The weather and bird protection grille can be installed from the shaft and provides the necessary weather protection on the outside wall. Characteristics Integrated flush-mounting of the ventilation flap (see specifications of JK-180 HV) Integration to thermal insulation Weather protection grille ALAS with fixed rain-repellent blades preventing the ingress of rain A supplementary grid protects against intrusion of birds Easy installation from the shaft or the machine room Mounting feet for easy attaching inside the opening s: spring return or low-noise direct current motor (ref....-db...) Vertical ventilation and protection, quite simply! Technical specification Louvres Bird protection grid Frame JK-180 HV-ALAS Galvanized steel Galvanized steel Galvanized steel Note The position of the smoke exhaust opening has to be planified in such a way that the smoke exhaust is not affected by the wind! certified according to: EN BlueKit ventilation flaps - September 2017

15 Ventilation flap with weather protection grille JK-180 HV-ALAS Mounting plate B2xH2 Opening dimensions B1xH1 Flap Frame Flap opening BxH Inside Outside Inside Outside Inside view Outside view Mounting feet dimensions Section Alternative section Weather protection grille depth (mm): 78 Ventilation flap depth (mm): 180 Minimum wall thickness (mm): 260 Articles and dimensions - JK-180 HV-ALAS Designation acc. to flap opening(mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,38 0,56 0,77 1,03 Opening dimensions (mm) B1xH1 590x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 Article number JK-180 HV-ALAS Article number JK-180 HV-ALAS-dB Other dimensions available upon request Application The weather protection grille is secured against falling with a safety line and placed diagonally through the opening to the outside. While pulling the grille against the outer wall, it is attached to the inside of the opening with the mounting feet. Finally, the ventilation flap incl. the sealing tape is placed in the opening and fixed to the inner wall through the drilling holes of the mounting plate. September BlueKit ventilation flaps 15

16 Insulated louvre windows S9-iVt-05 LF-MR and Tairmo-LF-MR Description Louvre window and mounting frame allowing a flush-mounted closure of the permanent lift shaft opening. The window is designed for a vertical and integrated installation inside the facade opening and guarantees optimal insulation thanks to excellent heat transfer coefficients. Characteristics Integrated flush-mounting Integration to thermal insulation Excellent thermal performance: low heat transfer coefficient (Ug-/Up-/Uw-value) Air permeability, water tightness and heat protection Sandwich panels (S9-iVt-05 LF-MR) or glass blade frame with triple glazing (Tairmo-LF-MR) Anti breakage Attractive architectural design in the facade Combine ventilation, energetic efficiency and modern design Tairmo-LF-MR S9-iVt-05 LF-MR Technical specification certified according to: EN Supplementary products Sealing tape expanding, used for sealing between the louvre window and shaft wall (included in the mounting set) 16 Louvres Material Power supply Torque Functional safety Run-time Sound power level S9-iVt-05 LF-MR / Tairmo-LF-MR Thermally separated aluminium profiles Sandwich panels / triple glazing Direct current motor 24 VDC 0,3 Nm... 4,5 Nm cycles (EN certification) ca. 4 sec. ca. 25 db Note The position of the smoke exhaust opening has to be planified in such a way that the smoke exhaust is not affected by the wind! BlueKit ventilation flaps - September 2017

17 Insulated louvre windows S9-iVt-05 LF-MR and Tairmo-LF-MR Outside view Outside view Inside Outside Inside Outside Section Section Mounting frame: 50 x 150 x 5mm (50 x 50 x 5 mm or 50 x 100 x 5 mm dimensions available upon request) Articles and dimensions S9-iVt-05 LF-MR Tairmo-LF-MR Designation according to the element dimensions BxH 420x x x x x x x x815 Net ventilation surface (m 2 ) 0,10 0,15 0,20 0,39 0,11 0,15 0,20 0,40 Opening dimensions (mm) B1xH1 450x x x x x x x x845 Uw-value (W/m 2 K) 2,5 2,3 2,3 2,1 1,9 1,8 1,7 1,6 Number of blades Article number Other dimensions available upon request Application The sealing tape is first placed on the wall sided edge of the mounting frame. The element is then aligned in the opening parallel to the opening edges, secured and fixed to the wall via wall anchors. September BlueKit ventilation flaps 17

18 Ventilation flap JK-190 Modernisation Description Smoke and heat exhaust ventilation (SHEV) device allowing a surface-mounted closure of the permanent lift shaft opening in existing buildings. The flap is fitted for horizontal or vertical non-integrated installation. The flap s spring return motor ensures its opening in case of power failure. Characteristics Non-integrated solution surface mounting Does not decrease the ventilation surface The additional 10 mm depth of the frame allows a wider ventilation surface (free movement of the blades and airflow increase between the blades) Can be adapted to all openings Easy ventilation flap installation and motor maintenance Louvres made of aluminum profile, streamlined and torsion-resistant Pre-assembled and pre-cabled motor Motor cabling with RJ45 connector for easy connection to BlueKit system Solution for the ventilation flap mounting in a corner with additional mounting angles (accessories) Motor with positive safety function in case of power failure The flexible solution for modernisations Spring return motor certified according to: EN Supplementary products Sealing tape expanding, used for sealing between the ventilation flap and shaft wall (included in the mounting set) 18 Technical specification JK-190 Louvres Aluminium Seals EPDM-rubber Material Profiled sheet steel, dimensionally stable Thickness 1,5 mm Spring return motor Power supply 24 VAC/DC Torque 20 Nm Functional safety cycles (EN certification) Service life emergency positions (manufacturer specifications) Run-time Closing via motor 150 sec. Opening via spring return 20 sec. Sound power level Closing via motor 40 db Opening via spring return 62 db BlueKit ventilation flaps - September 2017

19 Ventilation flap JK-190 Modernisation Section B-B Section A-A Spring return motor dimensions JK-190* Net ventilation surface (m2) Ventilation flap opening (mm) H/B ,1 0,16 0,21 0,26 0,31 0,37 0,15 0,23 0,31 0,38 0,46 0,54 0,2 0,3 0,41 0,51 0,61 0,71 0,25 0,37 0,5 0,62 0,75 0,87 0,3 0,45 0,6 0,75 0,9 1,05 0,35 0,52 0,7 0,87 1,04 1,22 * Most-used standard dimensions in grey Application The ventilation flap is used in front of the opening to mark the drilling points. After having drilled, the sealing tape is attached on the frame. The flap is then fixed to the wall through the drilling holes of the frame with wall anchors. September BlueKit ventilation flaps 19

20 Ventilation flap JK-190-dB Modernisation Description Smoke and heat exhaust ventilation (SHEV) device allowing a surface-mounted closure of the permanent lift shaft opening in existing buildings. The flap is fitted for horizontal or vertical non-integrated installation. The flap is equipped with a low-noise direct current motor. Characteristics Non-integrated solution surface mounting Does not decrease the ventilation surface The additional 10 mm depth of the frame allows a wider ventilation surface (free movement of the blades and airflow increase between the blades) Can be adapted to all openings Easy ventilation flap installation and motor maintenance Louvres made of aluminum profile, streamlined and torsion-resistant Pre-assembled and pre-cabled motor Motor cabling with RJ45 connector for easy connection to BlueKit system Solution for the ventilation flap mounting in a corner with additional mounting angles (accessories) Low-noise direct current motor Low noise level solution for mordernisations Direct current motor certified according to: EN Supplementary products Sealing tape expanding, used for sealing between the ventilation flap and shaft wall (included in the mounting set) 20 Technical specification Louvres Seals Material Thickness Power supply Torque Functional safety Run-time Sound power level JK-190-dB Aluminium EPDM-rubber Profiled sheet steel, dimensionally stable 1,5 mm Direct current motor 24 VDC 10 Nm cycles (EN certification) ca. 4 sec. ca. 25 db BlueKit ventilation flaps - September 2017

21 Ventilation flap Section B-B JK-190-dB Modernisation Section A-A Direct current motor dimensions * Most-used standard dimensions in grey JK-190-dB* Net ventilation surface (m 2 ) Ventilation flap opening (mm) H/B ,1 0,15 0,2 0,25 0,3 0, ,16 0,23 0,3 0,37 0,45 0, ,21 0,31 0,41 0,5 0,6 0, ,26 0,38 0,51 0,62 0,75 0, ,31 0,46 0,61 0,75 0,9 1, ,37 0,54 0,71 0,87 1,05 1,22 Application The ventilation flap is used in front of the opening to mark the drilling points. After having drilled, the sealing tape is attached on the frame. The flap is then fixed to the wall through the drilling holes of the frame with wall anchors. September BlueKit ventilation flaps 21

22 Accessories JK ceiling/corner Modernisation Description Mounting angles - Accessories for horizontal mounting of JK-190 and JK-190-dB Characteristics Ventilation flap JK-190 with mounting angles Solution for the ventilation flap mounting in a corner of the shaft ceiling when space for fixing is not sufficient Flexible mounting according to the access to the ventilation opening Application Fixing of angle corner (1) to the ventilation flap together with the supplied nuts Positioning of the ventilation flap including mounting angle (1) in front of the opening and screw mounting in the shaft slab Positioning of mounting angle (2) on the ventilation flap and screw mounting in the shaft wall 22 BlueKit ventilation flaps - September 2017

23 Accessories JK ceiling/corner Modernisation Section B-B Drawings and dimensions with mounting angles Section A-A Ceiling corner view 1 2 September BlueKit ventilation flaps 23

24 FURTHER INFORMATION Subject to technical changes. No responsibility is accepted for the accuracy of provided information. BK-Factory will not assume any responsibility for their use INNOVATION SAFETY EFFICIENCY EN_BLUEKIT_VENTILATIONFLAPS_

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres Incorporating V2.1 Product spec >>> > Series WL - Standard weather louvres Louvres Standard Recoended for: Exterior walls Intake & return Overview Good rain protection Flanged, recessed and reversed available

More information

Compact Design BB101 & 93

Compact Design BB101 & 93 Acoustic Shield Natural Ventilation Acoustic Roof Vents Compact Design BB101 & 93 Standard / Twin Flow / Mixed Mode natural ventilation roof vents can be finished in any colour to compliment the architectural

More information

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide Louvre systems Incorporating Series WL Standard range of single bank louvres as used in countless installations worldwide Good resistance to water ingress, with low resistance to airflow Approximately

More information

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL OHCL Outside Horizontal Closable Louvers - mm Curved Profile 226-228F OHCL 124 Outside Horizontal Closable Louvers

More information

Technical Information No.: CI System Rooflight Dome F100

Technical Information No.: CI System Rooflight Dome F100 Rooflight Dome Rooflight dome closed Rooflight dome opened in ventilation position Versatile accessory Variants of shading Connection and renovation options Different drive units Smart Home (electric control

More information

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK Е70 WINDOW AND DOOR SYSTEM WITH THERMAL BREAK TABLE OF CONTENTS GENERAL INFORMATION page 9 BUILDING PHYSICS page 17 TABLES page 25 PROFILES page 31

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver

More information

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide. Louvre systems Incorporating Series WL Standard range of single bank louvres as used in countless installations worldwide. Good resistance to water ingress, with low resistance to airflow. Approximately

More information

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres 0161 723 2234 sales@mckenziemartin.co.uk McKenzie Martin Louvres Louvres & Ventilation Systems Turret Louvres 0161 723 2234 sales@mckenziemartin.co.uk Description The Maximair Turret Louvre is a roof mounted

More information

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Type overview FSR with guide cables or rods Type key FSR P S 0 0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Cover panel without back-fold: S = small,

More information

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NEW. Wall controls. YFCN Fan Coil Units.     Technical Guide - for internal distribution only NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to

More information

Folding Sliding System SF55c

Folding Sliding System SF55c Profile system Glass folding door with thermally insulated aluminum profiles Bottom-loaded construction The construction depth of the profiles is 75 mm Rear-ventilated wooden cladding inside Option of

More information

Light + Air UK & Republic of Ireland. Multilateral Louvred Ventilator Data Sheet

Light + Air UK & Republic of Ireland. Multilateral Louvred Ventilator Data Sheet Light + Air UK & Republic of Ireland Multilateral Louvred Data Sheet 2 Multilateral Louvred Application Multilateral Louvered The Eura is a louvered ventilator that extracts large volumes of warm air and

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

Air Louvers OFAL 300 SERIES

Air Louvers OFAL 300 SERIES Fresh / Exhaust Model : OFAL GI 359 Description: Stationary Louvers is designed to provide air intake and air exhaust openings in building exterior walls to protect against the direct ingress of rain.

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular

More information

ESSMANN Double-flap for the arcade rooflight classic plus

ESSMANN Double-flap for the arcade rooflight classic plus ESSMANN Double-flap for the arcade rooflight classic plus Glazing variants with ESSMANN AeroTech available Product features Thermally isolated profile system Safety de-watering by means of a novel transom

More information

High-speed folding doors. F Series

High-speed folding doors. F Series High-speed folding doors F Series F Series The horizontal folding motion of high-speed folding doors ensures that the entire vertical clearance is achieved immediately. F Series doors open at high speed

More information

WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options

WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options brookvent.co.ukokvent.co.uk Who we are Brookvent are leading UK manufacturers of Energy Saving Ventilation Systems,

More information

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE Cert. n 0545 www.euroventcertification.com Carisma Fan Coil Unit The Ultra Quiet Fan Coil TECHNCAL GUDE Carisma CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page 6 EUROENT certification

More information

Schüco Premium Collectors Outstanding quality, performance and design

Schüco Premium Collectors Outstanding quality, performance and design Schüco Premium Collectors Outstanding quality, performance and design 2 Schüco Premium collectors Schüco Premium line collectors - The next generation Since its entry into the solar thermal sector, Schüco

More information

Automatic Roof Door Vents

Automatic Roof Door Vents DATA SHEET Automatic Roof Door Vents Features n UL Listed for use as an automatic smoke vent n FM Approved as an automatic door vent for use in high expansion foam systems n Available in multiple sizes

More information

GaraRoll Roller Garage Doors

GaraRoll Roller Garage Doors GaraRoll Roller Garage Doors NEW GaraRoll Lite roller door 2 GARADOR Roller garage door GaraRoll roller door 4 Why Choose a GaraRoll 10 GaraRoll Accessories 12 GaraRoll Optional Extras 13 GaraRoll Lite

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

Heat recovery units type GTDHR

Heat recovery units type GTDHR GTDHR Double flux - 4 m3/h AC 23V type GTDHR Double flux heat recovery unit high efficiency 9%. The range consists of 5 sizes and 6 types for air flow from up to 4 m³/h. Application Ventilation and heat

More information

Carisma The Ultra Quiet Fan Coil

Carisma The Ultra Quiet Fan Coil Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()

More information

FIRE CONTROL

FIRE CONTROL 48 FIRE CONTROL FIRE HOLD OPEN MAGNETS HYDRAULIC DAMPERS FOR SLIDING DOORS HYDRAULIC IMPACT SHOCK ABSORBERS SINGLE ZONE FI RE CONTROLLER FIRE AND SMOKE DETECTORS 49 50 FIRE CONTROL www.opera-italy.com

More information

GaraRoll Roller Garage Doors

GaraRoll Roller Garage Doors GaraRoll Roller Garage Doors NEW Roller doors with ventilation grilles 2 www.thegaragedoorcentre.co.uk 0800 525 442 GARADOR Roller garage door GaraRoll roller door 4 Why Choose a GaraRoll 10 GaraRoll Accessories

More information

CP 130 Sliding Door. CP 130 is a premium insulated sliding system combining high weather performance with enhanced security and great aesthetics.

CP 130 Sliding Door. CP 130 is a premium insulated sliding system combining high weather performance with enhanced security and great aesthetics. CP 130 Sliding Door CP 130 is a premium insulated sliding system combining high weather performance with enhanced security and great aesthetics. Available in slide or lift-and-slide variants, this sliding

More information

Light + Air Republic of Ireland & UK. Eura Ventilator Data Sheet

Light + Air Republic of Ireland & UK. Eura Ventilator Data Sheet Light + Air Republic of Ireland & UK Eura Data Sheet 2 Eura Application The Eura is a louvered ventilator that extracts large volumes of warm air and smoke within a short period of time. The Eura is both

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

Security steel door dw 62-1 Teckentrup

Security steel door dw 62-1 Teckentrup Teckentrup RC 2 Text example Compile and tender according to requirements. Please refer to technical data below for respective details. Updated 1 st June 2015 Position No. of pieces Item Security steel

More information

Louvre systems. Series WLSS / WLG Stainless / galvanised steel weather louvres. Incorporating

Louvre systems. Series WLSS / WLG Stainless / galvanised steel weather louvres. Incorporating Louvre systems Incorporating Series WLSS / WLG Fabricated weather louvre series from stainless or galvanised steel Stainless steel units offer superior corrosion resistance for harsh environments Stainless

More information

Folding Sliding System SF75

Folding Sliding System SF75 Profile system Folding wall in thermally insulated aluminium profiles. The structural depth of the profile is 75 mm, which corresponds with the structural requirements. The rated value of the heat transfer

More information

Natural Smoke and Heat Exhaust Ventilation Systems

Natural Smoke and Heat Exhaust Ventilation Systems Natural Smoke and Heat Exhaust Ventilation Systems Why extraction systems are necessary Most victims of fires are killed not by the fire itself, but by the smoke. The smoke created by a fire can fill whole

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

F Series. High-speed folding doors

F Series. High-speed folding doors F Series High-speed folding doors 02 F Series With construction methods responding to increasing architectural demands and constantly developing technology expectations are changing. In response to just

More information

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series

More information

Smart Visoglide Plus Sliding Door System

Smart Visoglide Plus Sliding Door System Smart Visoglide Plus Sliding Door System 1 P a g e Recommended Design Limitations - Maximum Sash Weight Maximum Sash Height Minimum Sash Height Maximum Sash Width Maximum Glass Thickness U Value 200kg

More information

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements Air Handling Units RM-/RL-Line AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements robatherm 11/2013 Characteristics of the robatherm casing construction

More information

Uw = 0.66W/m²K Uf = 0.77 W/m²K Ug = 0.50 W/m²K

Uw = 0.66W/m²K Uf = 0.77 W/m²K Ug = 0.50 W/m²K Uw = 0.66W/m²K Uf = 0.77 W/m²K Ug = 0.50 W/m²K Innovation is often spoken about, but very rarely delivered. Comar 0 offers a new departure, a Passivhaus certified product with U values as low as 0.66 coupled

More information

FOLDING DOORS LE-LN-LG SLIDING DOORS SN SHUTTER DOORS BT TECHNICAL MANUAL

FOLDING DOORS LE-LN-LG SLIDING DOORS SN SHUTTER DOORS BT TECHNICAL MANUAL FOLDING DOORS LE-LN-LG SLIDING DOORS SN SHUTTER DOORS BT TECHNICAL MANUAL LEGEND CE MARKING CERTIFICATION DATA LE FOLDING DOOR without bottom rail LN FOLDING DOOR without bottom rail LG FOLDING DOOR with

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

partial statement 106 TITUS www.efb-elektronik.de 19 Networking cabinet TITUS S (Standard)... 108-109 19 Networking cabinet TITUS E (Enhanced)...110-111 19 Networking cabinet TITUS V (pre-assembled)...

More information

SOLEAL HIGH PERFORMANCE DOOR. Architect agency: A+ Architecture Photo Marie-Caroline Lucat

SOLEAL HIGH PERFORMANCE DOOR. Architect agency: A+ Architecture Photo Marie-Caroline Lucat SOLEAL HIGH PERFORMANCE DOOR Architect agency: A+ Architecture Photo Marie-Caroline Lucat SOLEAL / DOORS AND 65 MM, A COMPLETE OFFER A CHOICE OF SOLUTIONS Modules depth of and 65-mm permit realisation

More information

NORDexternal External louvres

NORDexternal External louvres NORDexternal External louvres NORDexternal Contents RV External louvre RVT External louvre RVS External louvre RVA External louvre RVUK External louvre RVL Snow shield RVLU Snow shield RVB Combi air grid

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door Louvre systems Incorporating Series WLD Fully active louvre panel integrated into a door Full range of hardware from basic deadlocks to panic bars and door closers Good resistance to water ingress, with

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

Louvred Grilles can be used internally and externally are available with or without a flyscreen and provide excellent airflow performance.

Louvred Grilles can be used internally and externally are available with or without a flyscreen and provide excellent airflow performance. Mech-Elec. Available with round spigots or rectangular sockets to fit all ducting systems Various types for different applications External and internal options Choices for the wall, ceiling and roof Manufactured

More information

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! ROOF HATCHES SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! Over 45 years of proven performance in Standard & Custom Designed Hatches ROOF HATCHES Better by design LEXCOR COMPANY PROFILE Lexcor was incorporated

More information

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

BL Series Louvres. Factory Assembled Louvre Panels

BL Series Louvres. Factory Assembled Louvre Panels BL Series Louvres BL Series Louvres BL Series Louvres Factory Assembled Louvre Panels Amongst our standard product range, we have consistently offered a wide variety of made to measure louvres, to suit

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the

More information

SECTION WELDING FUME EXHAUST SYSTEM

SECTION WELDING FUME EXHAUST SYSTEM SECTION 233500 WELDING FUME EXHAUST SYSTEM PART 1 - GENERAL 1.1 WORK INCLUDES Welding fume exhaust system and controls Accessories Additional System Equipment Engineering Support Commissioning 1.2 RELATED

More information

Table of contents. Small cases:

Table of contents. Small cases: R Firmengruppe Table of contents Small cases: Small case x-dream 418......................... III 3 Small case Tarex 419............................ III 5 Small case Profi-case 415/416....................

More information

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

DVAX-ARS. Roof-mounted unit for mechanical smoke extract Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

ACCESSORIES FOR SZE2 CABINETS

ACCESSORIES FOR SZE2 CABINETS ZPAS 143 DOORS Doors Intended for use instead of front solid door or rear panel. Maximum door opening angle: 120 Sheet steel textured powder paint, light grey (RAL 7035), stiffened profiles, brown smoked

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P Chapter1 1 INDEX A. s 1....: AJD-P...11.1 Standard sizes...11.1 Fixing details...11.2 Panel arrangement...11.2 How to order...11.2 B. Air flow data 1. at o o position...: Tab: 11.1 (A)...11.3 2. at o position...:

More information

argco.com

argco.com 800-854-1015 argco.com STRUT SUPORT SYSTEM STRUT SUPPORT CHANNEL US Strut Support Channel Quick, strong attachment of single or multiple pipes horizontally or vertically Unlimited applications - range

More information

SECTION METAL LOCKERS

SECTION METAL LOCKERS SECTION 10 5113 METAL LOCKERS This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Transformer Stations

Transformer Stations ISO 9001 99-320 Żychlin, ul. Narutowicza 70 www.ftz.com.pl Secretary s Office Tel.: +48 24 285 46 05, Fax: +48 24 285 46 31, zarzad@ftz.com.pl Marketing and Sales Department Tel.: +48 24 285 18 53, Fax:

More information

Popular steel Atlas locker is available in a range of door options direct from stock with next day dispatch.

Popular steel Atlas locker is available in a range of door options direct from stock with next day dispatch. Popular steel Atlas locker is available in a range of door options direct from stock with next day dispatch. Atlas Range The Atlas locker is available in two popular depths - 300mm or 450mm, with a choice

More information

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief Gravity Ventilators Models FGI and FGR Fabra Hood Intake and Relief July 008 Page Fabra Header Hood Greenheck Fabra Hoods are designed for intake (Model FGI) or relief (Model FGR) applications with either

More information

VERTIGO - Vertical folding door SMART - Folding door without bottom rail LIBER - Folding door without bottom rail LIBRUM - Folding door with bottom

VERTIGO - Vertical folding door SMART - Folding door without bottom rail LIBER - Folding door without bottom rail LIBRUM - Folding door with bottom VERTIGO - Vertical folding door SMART - Folding door without bottom rail LIBER - Folding door without bottom rail LIBRUM - Folding door with bottom rail FLUX - Sliding door EXIT - Swinging door LEGEND

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

TECHNICAL SPECIFICATION FTP-V, FTW-V, FTU-V WOODEN PIVOT ROOF WINDOWS

TECHNICAL SPECIFICATION FTP-V, FTW-V, FTU-V WOODEN PIVOT ROOF WINDOWS FTP-V, FTW-V, FTU-V WINDOW TYPE FTP-V FTW-V FTU-V white colour Varnishing twice twice triple Air inlet type automatic V40P Air inlet capacity up to 49m 3 /h Elegant Air permeability class class 4 as per

More information

Eldon MultiFlex platform ACCESSORIES FULLY COMPATIBLE BETWEEN RANGES. MultiCOM Aluminium. MultiFlex

Eldon MultiFlex platform ACCESSORIES FULLY COMPATIBLE BETWEEN RANGES. MultiCOM Aluminium. MultiFlex Floor Standing NEWS The new Eldon MultiFlex platform - Easy to work with! In a major development, Eldon has standardized all of its floor standing product lines around its respected and best-selling MultiFlex

More information

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet Carisma CRC Fan Coil Unit with Centrifugal Fan with synchronous Motor Range includes 9 air rates (from to 1500 m /h) and 5 models (for wall and ceiling installation, with casing and concealed), each equipped

More information

Mini amateur football ground goals, street hockey goals, mobile, fully welded

Mini amateur football ground goals, street hockey goals, mobile, fully welded Fully welded Mini amateur football ground goals, street hockey goals, mobile, fully welded GS-APPROVED Completely made of aluminium Extremely robust and low risk of injury Goal frame square profile 80

More information

2 The Isle of Cold Server enclosures. outdoor enclosure

2  The Isle of Cold Server enclosures. outdoor enclosure CATALOGUE HB2 outdoor enclosure HB2 based on the frame construction with mounted panel walls, made of aluminium sheet. The enclosure is an answer for market s needs connected with telecommunication industry

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50

Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 L Roller shutters and roller doors Aluminium roller shutters ROLL-TO 50 Aluminium roller shutters ROLL-TO 50 Roller door plastic panel POLAR PLUS Roller door wooden panel ARBOR PLUS Roller door aluminium

More information

SKYLIGHTS TECHNICAL FILE. Skylux iwindow2 TM & iwindow3 TM. Complete set glass skylight

SKYLIGHTS TECHNICAL FILE. Skylux iwindow2 TM & iwindow3 TM. Complete set glass skylight SKYLIGHTS TECHNICAL FILE iwindow2 TM & iwindow3 TM Complete set glass skylight Skylux iwindow Skylux Openable spindle actuator General product description Pvc curb With remote control The iwindow is a

More information

Round duct diffuser DBB-RR

Round duct diffuser DBB-RR Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Mondrian CWS-50 Slim Product Information Sheet

Mondrian CWS-50 Slim Product Information Sheet Glass 6mm toughened outer / 16mm argon filled cavity / 6mm toughened inner with low e coating Available on request Low Iron Glass, Low Maintenance Coatings, Solar Control Coatings, IQ Heated Glass, Privacy

More information

USS - External Louvre. Halton USS. External Louvre

USS - External Louvre. Halton USS. External Louvre Halton USS External Louvre External louvre for air intake and exhaust to prevent rain, snow, leaf and animal ingress Rainwater ingress penetration efficiency of approx. 95% (USS/I) Operation based on special

More information

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket POLYESTER ENCLOSURE SINGLE DOOR Product Datasheet GRP Single Door Enclosures are used for outdoor application with weatherproof and antistatic properties, finding their major application in the protection

More information

Unlimited creativity Think outside the box

Unlimited creativity Think outside the box Content: 8 RIB 11 MIDRIB 12 FLUSH 15 GEORGIAN (CASSETTE) 16 SLICK 19 SLICK PLUS 20 MICRORIB 23 MACRORIB 25 TOPRIB 27 SLIM LINE 28 RETRO 31 SIDE HINGED GARAGE DOORS 35 SIDE DOORS 38 PASS DOORS 40 DECOR

More information

Small cases... the perfect shell for valuable electronics

Small cases... the perfect shell for valuable electronics Small cases... the perfect shell for valuable electronics Small cases page 178 mini page 181 page 183 all standard size cards (100, 120, 160, 190 to 233,35 ) can be installed in one case favourable EMC

More information

PRIMEX VENTING PRODUCTS AND ACCESSORIES

PRIMEX VENTING PRODUCTS AND ACCESSORIES Index ACCESS PANELS... 14-15 DIFFUSERS CEILING AND SIDEWALL WG Series ADJUST-A-VENT... 14-2 WGX Series TRUE-FLOW VENT... 14-2 SQUEEZE ELBOW 90 EB4X90... 14-5 termination diffuser collars... 14-3 TRIM PLATEs

More information

Mounting SySteMS ApplicAtionS overview version 1.2 March 2013

Mounting SySteMS ApplicAtionS overview version 1.2 March 2013 Mounting Systems Applications Overview Version 1.2 March 2013 tritec Mounting Systems: Applications Overview I. Pitched Roof: Roof-Top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND on tiles 1.1.1

More information

Arte. Possibilities. Architecture for the future. Endless. Standard Profiles Nunc Et Orci Morbi Posuere. Arte Profiles Options. Arte Window Options

Arte. Possibilities. Architecture for the future. Endless. Standard Profiles Nunc Et Orci Morbi Posuere. Arte Profiles Options. Arte Window Options Possibilities Arte Endless Architecture for the future Standard Profiles Nunc Et Orci Morbi Posuere Arte Profiles Options Page 4 Arte Window Options Arte Door Options Page 13 Page 25 Table of Contents...

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

BESPOKE ENTRANCE SOLUTIONS

BESPOKE ENTRANCE SOLUTIONS BESPOKE ENTRANCE SOLUTIONS COMPLETE CONCEPTS FROM THE DAD GROUP Uniclass L861 Cl/SfB (71) X EPIC Q621 BESPOKE ENTRANCE SOLUTIONS COMPLETE CONCEPTS FROM THE DAD GROUP DAD combines precision construction

More information

19 floor rack with steel door

19 floor rack with steel door 19 floor rack with steel door Rack width 600 mm Rack width 800mm General features include a metal frame, 19 rails, roof, side and rear panels, door and plinth corners. Standard structure includes a lockable

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation

More information

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-300 Ceiling induction diffuser DISA-300 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

RG75 Catalogue.

RG75 Catalogue. RG5 Catalogue 1 www.balkan.gr 2 RG5 Catalogue 1 Catalogue cover 2 Catalogue pages Overview 3 Design Description 4 System Description 5 System Description 6 Design Description Table Composite Profiles,

More information