1 Cylinder & Cylinder & Cylinder & Cylinder sensors are used to provide end-ofstroke and position detection for hydraulic and pneumatic cylinder applications. Hydraulic cylinder walls are typically made of steel. Since inductive and magnetic field sensors cant see through the steel cylinder wall to detect the piston inside, hydraulic cylinders use pressure-rated inductive sensors that can handle direct exposure to pressurized hydraulic fluid in the cylinder to provide end-ofstroke detection. A specialized inductive sensor is bolted or threaded into the cylinder end cap. The sensing face of the inductive sensor directly detects the cylinder rod or cushion as it reaches its end of travel. For n-contact, wear-free position detection of pneumatic cylinder piston position, Balluff magnetic field sensors use magneto-resistive techlogy to detect the piston magnet through the aluminum wall of the cylinder. Typically two sensors are employed to provide end-of-stroke detection in both directions, or can be placed anywhere along the length of the cylinder to detect cylinder position. Advantages of Balluff magnetic field sensors include universal compatibility with either Hall Effect or Reed Switch cylinder magnet polarizations, reduction or elimination of double switch points, higher ise immunity, and elimination of electrical contact wear and sticking. Magnetic field sensors are available in a variety of cylinder-friendly mounting configurations, as well as with special features like weld field immunity..2 Selection Guide. BMF 103 Compact.8 BMF 273 C-Slot.9 BMF 303 Miniature Slot Mount.12 BMF 30 Universal & Universal Metal.22 BMF 307 T-Slot.24 BMF 31 Drop In T-Slot.27 BMF 21 Tie-Rod.29 BMF 32 Rugged Duty.32 BMF 07M, 08M, 12M Prox Style.34 Installation Hints.3 BMF Techlogy Comparison.36 BIL Magneto-Inductive Position Sensor Power Clamp & Gripper Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

2 Selection Guide Selection Guide Series BMF 103 BMF 273 BMF 303 BMF 30K BMF 30M Compact C-Slot Miniature Slot Universal Universal Metal Cylinder Type C-Slot HW-41/42 HW-28/30/31/62 HW-32 (Norgren) HW-32 (Norgren) T-Slot HW-43/63/6/ 79/81 HW-33/40/1/ 60/66 HW-17/20/22/ 23/26/37/0/2/ 3/8/64/67/82 HW-17/20/22/ 23/26 Dove Tail HW-68/7/78 HW-44/69 HW-3/36/38/ 39/4/46/47 HW-3/36/38/ 39/4/46/47 Trapezoidal HW-80 HW-2/27 HW-2/27 Round HW-34/9/61/80 HW-24 HW-24 Tie Round HW-74 HW-21 & HW-8/ HW-21 & HW-10 HW-70/71/72/76/77 HW-21 & HW-8/ HW-21 & HW-10 HW-70/71/72/76/77 Duo Rail Flush Mount Bracketless Connection Integral Connector Pigtail Connector M and M8 M8 M and M8 M8 and M12 Prewired Cable Outputs PNP N.O. 3-Wire PNP N.C. 3-Wire NPN N.O. 3-Wire NPN N.C. 3-Wire PNP N.O. Weld Field Immune 3-Wire NPN N.O. Weld Field Immune 3-Wire PNP N.O. Reed 3-Wire AC/DC Reed 2-Wire V AC/DC Housing Plastic LCP PBT LCP LCP Metal AL Attributes Short Circuit Protection Reverse Polarity Protection Temperature Range Up to 8 C Temperature Range Up to 10 C CE UL Features Pages Optimized for shortstroke cylinders, very compact size, perpendicular mounting, interchangeable brackets. Bracketless type designed for drop in installation into C slot.8 Miniature type for flush mounting in narrow channels, interchangeable brackets.9 Universal sensor designed for most applications; wide variety of outputs, connections, mounting options; plastic housing.12 &.1 Universal sensor designed for most applications; wide variety of outputs, connections, mounting options; metal housing; weld immune extended temperature range.14.2

3 Selection Guide Cylinder & Selection Guide BMF 307 T-Slot HW-73 HW-86 BMF 31K Drop In T-Slot HW-73 BMF 31M Drop In T-Slot Metal HW-73 BMF 21 Tie-Rod HW-11 HW-8/10/10E HW-8 BMF 32 Rugged Duty HW-12/14/18 HW-73 HW-13/1/34 BMF 7M, 8M, 12M Prox Style Cylinder & M8 M8 M8 and M12 M8 M8 and M12 M12 M V AC/DC LCP PA 66 AL PBT AL CuZn Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors Bracketless type for flush installation into T-slot channels.22 Bracketless type designed for drop in replacement into T-slot channels, plastic housing.24 Bracketless type designed for drop in replacement into T-slot channels, metal housing, weld immune extended temperature range.2 Cost-effective, optimized for mounting on tie rod cylinders.27 Rugged metal housing for the most demanding applications, tie rod mounting, available in weld immune.29 Designed for long range target sensing, extremely high switching speeds, suitable for tachometer applications, available in 7, 8, and 12 mm diameters.32 7Accessories o Product Overview t Technical Reference p Part Number Index

4 Selection Guide Selection Guide Series BIL Strokemaster Power Clamp Pressure Rated Bracket Required Connection Integral Connector M8 M12, Mini M8, M12, M18 M12 Pigtail Connector M12 Cable Outputs PNP N.O V PNP N.C V NPN N.O. NPN N.C. PNP N.O. Weld Field Immune AC/DC V AC/DC V ma Housing Plastic PA Metal SS/AL SS, SS430F Attributes Overload Protection Short Circuit Protection Reverse Polarity Protection Temperature Range Up to 7 C Up to 70 C Up to 120 C Up to 70 C Pressure Range 3000 PSI Up to 720 PSI CE UL Features Non-contact position feedback, ideal for short and medium stroke length applications; 10 to 160 mm stroke length Weld field immune, pressure rated to 3000 psi, sealed directly at flange, can be oriented after installation, various lengths available Pressure rated as high as 720 psi, corrosion resistant stainless steel housing, wide variety of housing diameters and thread lengths Designed for use in power clamp and gripper applications, incorporates two sensors into one unit to detect open or closed position, weld field immune Pages

5 BMF 103 Cylinder & BMF 103 Compact Magnetic Field Series Connection Type BMF 103 To create the compact BMF 103 magnetic field sensor, Balluff engineers employed GMR (giant magnetoresistive) techlogy to shrink the length of the sensor housing. The perpendicular cable exit and extremely short sensing face allow two BMF 103's to be placed as close together as mm in a single channel. The BMF 103 is the perfect solution for cramped spaces and today s short-stroke, compact pneumatic cylinders and actuators. PNP NPN Normally-open Normally-closed Normally-open BMF 103 Cable + M0 Pico Connector (S26) BMF 103K-PS-C-2A-S26-** BMF 103 Cable + M08 DC Na Connector (S49) Rotating Threaded Connector BMF 103K-PS-C-2A-SA2-S49-** BMF 103K-PO-C-2A-SA2-S49-** BMF 103K-NS-C-2A-SA2-S49-** BMF 103 PuFlex Cable BMF 103K-PS-C-2A-PU-* BMF 103K-PO-C-2A-PU-* BMF 103K-NS-C-2A-PU-* Cylinder & Rated operating field strength H nl Assured operating field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U B Voltage drop U d Rated insulation voltage Ui Rated operating current I e No-load supply current I 0 max. Off-state current Ir Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2. V 100 ma ma C LCP M pigtail BKS-B 2-3-PU ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2. V 100 ma ma C LCP M8 pigtail C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2. V 100 ma ma C LCP cable, PUR 3 30 AWG Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors Wiring diagrams PNP/Cable PNP/Connector NPN/Cable Output current temperature curves 7Accessories o Product Overview t Technical Reference p Part Number Index

6 BMF 103 Brackets BMF 103 Typical Ordering Code BMF 103-HW-41 Advantages Cylinder channel C-slot bracket e.g. SMC, Bimba Internal Set Screw BMF 103-HW-42 C-slot Festo Slot-10 Advantages BMF 103-HW-43 Internal Set Screw T-slot Adjust switchpoint in seconds! Turn screw one revolution, adjust position, tighten. Switchpoint can't be lost. Even if you replace the sensor, the adjusted switchpoint is retained by the mounting bracket. BMF 103-HW-63 e.g. Festo Slot-8, Bosch, SMC External Set Screw T-slot Can be inserted into slot from above. e.g. Bimba Flat 1 To order a combo kit of sensor with mounting bracket, include the bracket code in the part number. Example : BMF 103K/HW41- PS-C-2-PU-03 BMF 103-HW-6 BMF 103-HW-68 T-slot e.g. Parker P1M Dovetail e.g. Fabco Pancake.6

7 BMF 103 Cylinder & BMF 103 Brackets Ordering Code BMF 103-HW-74 BMF 103-HW-7 Advantages Cylinder channel Tie Rod e.g. PHD Dove Tail bracket M2x0.4-6H M3X0.-6H M3X0.-6H M2x0.4-6H 3.20 Ø10 Ø º.30 60º 6.70 Cylinder & e.g. Numatics BMF 103-HW-78 Dove Tail 60 BMF 103-HW-79 BMF 103-HW Rexroth PSK Rail Rexroth CKK Rail e.g. Norgren Small Bore M3X0.-6H Ø9.3 Ø8.6 60º Ø6.9 M2x0.4-6H M3X0.-6H M2x0.4-6H M3X0.-6H M2x0.4-6H Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

8 BMF 273 for C-slot BMF 273 BMF 273 The compact sensor for pneumatic cylinders with C-slot Series Connection Type BMF 273 Cable and M08 DC na (S49) BMF 273 PuFlex Cable The C-slot is becoming increasingly common in pneumatic cylinders and grippers. Installation from above into the slot is a requirement for fast and simple installation. The BMF 273 meets all these requirements while also offering reliable switching characteristics. Features Can be installed from above into the C-slot Disappears into the slot Proven electronics from the BMF line: Low hysteresis, precise switching point Rugged, compact low profile housing Hold-down screw protected from over-tightening, uses standard screw driver Cable clip for ease of cable routing and securing Install without a mounting bracket, for cylinders with C-slot, e.g. Festo (Slot 10), SMC, Parker and Sommer Automatik Wiring diagrams N.O. PNP/cable PNP/ NPN/ N.C. NPN/cable PNP/ PNP NPN Normally-open Normally-closed Normally-open Normally-closed Rated switching field strength I H n I Assured switching field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U S Voltage drop Ud Rated insulation voltage U i Rated operational current I e No-load supply current I0 max. Polarity reversal protected Short circuit protected Ambient temperature range Ta LED Protection per IEC 6029 Housing material Connection type No. of wires gauge Approval Recommended * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. BMF 273K-PS-C-2A-SA2-S49-** BMF 273K-PO-C-2A-SA2-S49-** BMF 273K-NS-C-2A-SA2-S49-** BMF 273K-NO-C-2A-SA2-S49-** 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2. V 100 ma 8 ma C PBT M8 pigtail C49 ANE-00-VY-00M BMF 273K-PS-C-2A-PU-* BMF 273K-NS-C-2A-PU-* 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2. V 100 ma 8 ma C PBT Cable, PUR 3 26 AWG Output current temperature curves NPN/.8

9 BMF 303 Cylinder & BMF 303 Minature Slot Mount Series Connection Type BMF 303 The BMF 303 is flush mounted in the cylinder slot. So small it disappears completely. Nothing to stick out thing in the way! Features - Non-contact, wear-free position sensing - Can be installed on any standard cylinder using specific mounting brackets - No "double switch points" - Insensitive to contamination PNP NPN Normally-open Normally-closed Normally-open Normally-closed BMF 303 Cable + M0 Pico Connector (S26) BMF 303K-PS-C-2A-S26-** BMF 303K-NS-C-2A-S26-** BMF 303 Cable + M08 DC Na Connector (S49) Rotating Threaded Connector BMF 303K-PS-C-2A-SA 2-S49-** BMF 303K-PO-C-2A-SA 2-S49-** BMF 303K-NS-C-2A-SA 2-S49-** BMF 303K-NO-C-2A-SA 2-S49-** BMF 303 PuFlex Cable BMF 303K-PS-C-2A-PU-* BMF 303K-PO-C-2A-PU-* BMF 303K-NS-C-2A-PU-* BMF 303K-NO-C-2A-PU-* Cylinder & Rated operating field strength H nl Assured operating field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U B Voltage drop Ud Rated insulation voltage U i Rated operating current I e No-load supply current I0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2 V 100 ma ma C LCP M pigtail BKS-B 2-3-PU-0 Wiring diagrams PNP/Cable 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2 V 100 ma ma C LCP M8 pigtail C49 ANE-00-VY-00M PNP/Connector 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 0.07 ms 0.07 ms 2 V 100 ma ma C LCP cable, PUR 3 30 AWG Output current temperature curves Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview Typical NPN/Cable NPN/Connector t Technical Reference p Part Number Index

10 BMF 303 Brackets BMF 303 Advantages Sensor disappears in the slot! Ordering Code BMF 303-HW-28 Advantages Cylinder channel bracket C-slot Can be inserted into slot from above. Adjust switchpoint in seconds! Turn screw one revolution, adjust position, tighten. BMF 303-HW-30 e.g. SMC C-slot Festo Nut-10 Switchpoint can't be lost. Even if you replace the sensor, the adjusted switchpoint is retained by the mounting bracket. BMF 303-HW-31 C-Nut Other bracket solutions are available. Contact factory for details. To order a combination kit of sensor with mounting bracket, include the bracket code in the part number. Example: BMF 303K/HW30-PS-C-2-PU-03 BMF 303-HW-33 e.g.festo T-slot Installation of BMF 303-HW-60 BMF 303-HW-34 e.g. Festo Nut-8, Bosch, SMC Round Cylinders Ø < mm M Ø2.8 Tube cuffs for BMF 303-HW-9/61 SCHLAUCHSCHELLE BMF GR. Pneumatic Tube Cuff Sizes Tube Cuff Piston Ø Cylinder Ø Size 0 < BMF 303-HW-40 BMF 303-HW-40 BMF 303-HW-44 T-slot e.g. Festo Nut-8, Bosch, SMC Dovetail 60 /90 e.g. Festo, Bosch, Numatics, Hoerbiger-Origa, Norgren-Martonair.10

11 BMF 303 Cylinder & BMF 303 Brackets Ordering Code BMF 303-HW-1 BMF 303-HW-60 BMF 303-HW-9 BMF 303-HW-61 BMF 303-HW-62 Advantages Cylinder channel bracket T-slot A T-Slot B Round Cylinders Ø mm HW9 HW1 HW61 HW60 Cylinder & Selection Guide BMF 303-HW-66 T-slot e.g. Parker P1M M2x0.4-6H.90 Ø2.8 Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive BMF 303-HW-69 Dovetail M2x0.4-6H Cylinder Position º Ø2.8 Power Clamp & Gripper 6Connectors e.g. Fabco Pancake BMF 303-HW-80 7Accessories o Product Overview t Technical Reference e.g. Bosch p Part Number Index

12 BMF 30 BMF 30 BMF 30 With its versatile mounting system, the BMF 30 is the most flexible magnetic field sensor available. A wide selection of interchangeable brackets allows the BMF 30 to fit virtually any cylinder type. Series Connection Type BMF 30 Cable + M08 DC Na Connector (S49) Rotating Threaded Connector Features Interchangeable bracket system Non-contact and wearfree sensing of piston location Insensitive to contamination Detects piston position through the cylinder wall Can be attached to any standard cylinder size using available mounting brackets Eliminates multiple switchpoints Brackets for all common cylinder types Pre-wired cable or quick disconnect Weld-immune version available PNP NPN Normally-open Normally-closed Normally-open Normally-closed Rated operating field strength H nl Assured operating field strength I Ha I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U B Voltage drop U d Rated insulation voltage U i Rated operating current I e No-load supply current I 0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended BMF 30K-PS-C-2-SA2-S49-** BMF 30K-PO-C-2-SA2-S49-** BMF 30K-NS-C-2-SA2-S49-** BMF 30K-NO-C-2-SA2-S49-** 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C LCP M8 pigtail C49 ANE-00-VY-00M * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. To order a set (sensor and mounting bracket): Please include the bracket code in the part number e. g. BMF 30K/HW20-PS-C-2-PU-0.12

13 BMF 30 Cylinder & BMF 30 Universal Sensor BMF 30 Cable + M12 DC Micro Connector (S4) BMF 30K-PS-C-2-S4-** BMF 30 PuFlex Cable BMF 30K-PS-C-2-PU-* BMF 30K-PO-C-2-PU-* BMF 30K-NS-C-2-PU-* BMF 30K-NO-C-2-PU-* BMF 30 Cable + M12 DC Micro Connector (S4) Weldfield Immune BMF 30K-PS-W-2-SA3-S Wiring diagrams Normally-open PNP/Cable PNP/Connector NPN/Cable NPN/Connector Normally-closed PNP/Cable Cylinder & 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C LCP M12 pigtail C04 AEL-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C LCP cable, PUR 3 26 AWG 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 4 V 20 ma C LCP M12 pigtail C04 AEL-00-VY-00M PNP/Connector NPN/Cable NPN/Connector Output current temperature curves Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

14 BMF 30 BMF 30 Series Connection Type BMF 30 M12 DC Micro Connector (S4) BMF 30 M08 DC Na Connector (S49) BMF 30 M08 DC Na Connector (S49) BMF 30 M12 DC Micro Connector (S4) Welding applications are problem for the BMF 30M/ series magnetic field sensors. Developed with a heavy-duty weld slag resistant metal housing and a specially tuned output circuit (immunity for weld currents up to 2kA), these sensors perform in even the toughest environments. Extended Temperature Weldfield Immune PNP Normally-open BMF 30M-PS-C-2-S4 BMF 30M-PS-C-2-S49 BMF 30M-PS-C-2-SA4-S49 BMF 30M-PS-W-2-S4 Rated operating field strength H nl Assured operating field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I H n Turn-on delay Turn-off delay Supply voltage U B Voltage drop U d Rated insulation voltage U i Rated operating current I e No-load supply current I 0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C Al C04 AEL-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C Al C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 3 %/ C 3.1 V 30 ma C IP 6 Al C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 4 V 30 ma C Al C04 AEL-00-VY-00M Wiring diagrams PNP/Cable NPN/Cable Output current temperature curves PNP/Connector NPN/Connector.14

15 BMF 30 Cylinder & BMF 30 Reed Switch Series Connection Type BMF 30 Reed Switch The ecomical BMF 30K-R reed switch has an LED for function display and as a setup aid. The recovery diode for switching an inductive load is already integrated. Features Fast and easy to install Fits any standard cylinder size using available brackets No loss of the setpoint when replacing a switch DC AC/DC PNP, Normally-open Normally-open BMF 30 Cable + M08 DC Na Connector (S49) BMF 30K-R-PS-F-3-S49-** BMF 30 PuFlex Cable BMF 30K-R-PS-F-3-* BMF 30 PuFlex Cable BMF 30K-R-US-L-3-* Cylinder & Turn-on delay Turn-off delay Supply voltage U B Reed contact rating max. Rated operating current I e Minimum operating current Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range Ta LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. To order a combination kit of sensor with mounting bracket, include the bracket code in the part number. Example: BMF 30K/HW20-PS-C-2-PU ms 0.2 ms 10 W 00 ma 0. µf C IP 6 LCP M8 pigtail C49 ANE-00-VY-00M 0.7 ms 0.2 ms 10 W 00 ma 0. µf C IP 6 LCP cable, PVC 3 26 AWG 0.7 ms 0.2 ms Vac/Vdc 10 W 128 ma at 24 Vac/Vdc 86 ma at 11 Vac/Vdc 43 ma at 230 Vac/Vdc 3 ma C IP 6 PA cable, PVC 2 26 AWG Note: Reed switch is configured for PNP operation with respect to operation of the function LED. The reed switch itself is inherently bi-directional for current. This applies to DC versions only. Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview Wiring Diagrams DC/Cable DC/Connector AC/DC/Cable t Technical Reference p Part Number Index

16 Installation Benefits BMF 30 Brackets BMF 30 Ordering Code BMF 30-HW-17 Advantages Cylinder Channel T-slot Bracket Can be inserted into slot from above. e.g. Festo, SMC BMF 30-HW-20 T-slot Switchpoint is set in seconds! Turn screw one revolution, adjust position, tighten. Switchpoint can't be lost. Even if you replace the sensor, the same switchpoint remains because the bracket doesn't move. without Set screw with Set screw BMF 30-HW-21 together with BMF 21-HW-8 BMF 30-HW-21 together with BMF 21-HW-10 BMF 30-HW-22 T-slot Tube Cuffs for BMF 30-HW-24: SCHLAUCHSCHELLE BMF GR. BMF 30-HW-23 T-slot Pneumatic Tube Cuff Sizes Tube Cuff Piston Ø Cylinder Ø Size 0 < BMF 30-HW-24 BMF 30-HW-2 without slot round cylinder with piston diameter < mm trapezoidal slot.16

17 BMF 30 Ordering Code BMF 30-HW-26 BMF 30-HW-27 Advantages Cylinder Channel T-slot A T-slot B Trapezoidal guide Cylinder & Bracket Position for T-slot A Position for T-slot B BMF 30 Brackets Cylinder & e.g. Bosch BMF 30-HW-32 C-slot Selection Guide BMF 30-HW-3 e.g. Norgren Dovetail slot Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive BMF 30-HW-36 e.g. Tol-o-matic Dovetail slot Cylinder Position 6.6 Power Clamp & Gripper Connectors e.g. Numatics 7Accessories BMF 30-HW-37 T-slot o Product Overview 12.7 t Technical Reference p Part Number Index e.g. Parker, SST, ER

18 Installation Benefits Can be inserted into slot from above. Switchpoint is set in seconds! Turn screw one revolution, adjust position, tighten. Switchpoint can't be lost. Even if you replace the sensor, the same switchpoint remains because the bracket doesn't move. BMF 30 Brackets BMF 30 Ordering Code BMF 30-HW-38 BMF 30-HW-39 BMF 30-HW-4 Advantages Cylinder Channel 7 14 mm dovetail e.g. De-Sta-Co mm dovetail e.g. Compact Air 4 12 mm dovetail Bracket O7 6.9 M3 4. O e.g. Norgren BMF 30-HW mm dovetail O8.8 O BMF 30-HW-47 e.g. Norgren small bore mm dovetail O16.2 O e.g. Norgren large bore BMF 30-HW-0 T-slot BMF 30-HW-2 T-Rail M3x0.-6H O3.3 2mm e.g. SMC.18

19 BMF 30 Ordering Code BMF 30-HW-3 BMF 30-HW-8 Advantages Cylinder Channel.00 T-slot e.g. PHD T-slot M Cylinder & Bracket O12 O8 BMF 30 Brackets Cylinder & BMF 30-HW-64 BMF 30-HW-67 T-slot T-slot Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

20 Installation Benefits Can be inserted into slot from above. BMF 30 Brackets BMF 30 Ordering Code BMF 30-HW-70 BMF 30-HW-71 BMF 30-HW-72 Advantages Cylinder Channel Bracket Switchpoint is set in seconds! Turn screw one revolution, adjust position, tighten. Switchpoint can't be lost. Even if you replace the sensor, the same switchpoint remains because the bracket doesn't move. Cylinder Size 1." 2" 2." 3.2" 4" " 6" 8" Bracket BMF 30-HW-70 BMF 30-HW-70 BMF 30-HW-70 BMF 30-HW-71 BMF 30-HW-71 BMF 30-HW-72 BMF 30-HW-72 BMF 30-HW-72 BMF 30-HW-76 Parker 2 MA 3/4" Ø16.2 M3x0.-6H (2X)

21 BMF 30 Ordering Code Advantages BMF 30-HW-77 BMF 30-HW-82 Cylinder Channel Tie rod 3/4" T-slot e.g. Exlar Bracket Ø Ø19.0 Cylinder & M3x0.-6H (2X) M4x0.7-6H Ø9.0 M3x.0-6H Ø BMF 30 Brackets Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

22 BMF 307 T-slot sensors BMF 307 Series Connection Type BMF 307 Cable + M08 DC Na Connector (S49) BMF 307 PuFlex Cable BMF 307 Cable + M08 DC Na Connector (S49) BMF 307 The BMF 307 magnetic field sensor is a T-slot style that fits many popular pneumatic cylinders such as Festo and SMC. The BMF 307 is a bracketless design featuring an integrated set screw in the housing LED M8x1 Max. 40 PNP NPN Normally-open Normally-closed Normally-open Normally-closed BMF 307K-PS-C-2-SA2-S49-** BMF 307K-PO-C-2-SA2-S49-** BMF 307K-NS-C-2-SA2-S49-** BMF 307K-NO-C-2-SA2-S49-** BMF 307K-PS-C-2-PU-* BMF 307K-PO-C-2-PU-* BMF 307K-NS-C-2-PU-* BMF 307K-NO-C-2-PU-* AC/DC BMF 307K-R-AS-L-3-S49-** Rated operating field strength H nl Assured operating field strength I H a I Hysteresis of I Hn I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U B Voltage drop U d Rated insualtion voltage Ui Rated operating current I e No-load supply current I 0 max. Off-state current Ir Reed contact rating max. Minimum operating current Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range Ta LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C LCP M8 pigtail C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 30 ma C LCP cable, PUR 3 26 AWG 0.7 ms 0.2 ms Vac/Vdc 128 ma at 24 Vac/Vdc 10 W 3 ma 0. µf C IP 6 LCP M8 pigtail C49 ANE-00-VY-00M * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options..22

23 BMF 307 Cylinder & BMF 307 T-slot sensors BMF 307 Cable + M12 DC Micro Connector (S4) LED Max. 46 BMF 307K-PS-C-2-S4-** BMF 307 PuFlex Cable Wiring diagrams Normally-open AC/DC Reed Connector PNP/cable PNP/ NPN/cable PNP/ Normally-closed AC/DC Reed Cable Cylinder & 1.2 ka/m (1 Gauss) 2 ka/m (20 Gauss) 4 % 0.3 %/ C ac/vdc 3.1 V 30 ma C LCP M12 pigtail C04 AEL-00-VY-00M BMF 307K-R-AS-L-3-* 0.7 ms 0.2 ms Vac/Vdc 128 ma at 24 Vac/Vdc 10 W 3 ma 0. µf C IP 6 LCP cable, PVC 2 26 AWG Output current temperature curves BMF 307-HW (14.4) (14) Ø Piston Ø Inch 1 1/4 1 1/ /2 3 4 mm Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors BMF 307-HW BMF 307-HW-73-2 Tube cuffs Piston Ø Cuff Size BMF 307-HW BMF 307-HW Accessories o Product Overview t Technical Reference p Part Number Index

24 BMF 31 Replacement for T-slots BMF 31 The first choice for pneumatic cylinders with T-slot The T-slot has w become established as the standard slot type for pneumatic cylinders. Series Connection Type BMF 31 Cable + M08 DC Na Connector (S49) Rotating Threaded Connector BMF 31 PuFlex Cable To shorten assembly time, the ability to install from above is critical. max. 1, Nm max. 1, Nm The BMF 31 meets every requirement and stands out with its reliable switching characteristics and wide range of sensing performance. For especially demanding applications you can choose between weld immune or temperature rated versions. Features Proven electronics from the BMF line of sensors Can be installed in the T-slot from above Rugged, compact, low-profile housing Extremely reliable switching behavior PNP NPN Normally-open Normally-closed Normally-open Normally-closed BMF 31K-PS-C-2-SA2-S49-** BMF 31K-PO-C-2-SA2-S49-** BMF 31K-NS-C-2-SA2-S49-** BMF 31K-NO-C-2-SA2-S49-** BMF 31K-PS-C-2-PU-* BMF 31K-PO-C-2-PU-* BMF 31K-NS-C-2-PU-* BMF 31K-NO-C-2-PU-* Wiring diagrams Normally-open PNP/Cable PNP/Connector NPN/Cable NPN/Connector Normally-closed PNP/Cable PNP/Connector NPN/Cable NPN/Connector Rated operating field strength H nl Assured operating field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage UB Voltage drop U d Rated insualtion voltage U i Rated operating current Ie No-load supply current I 0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range Ta LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. **Please specify length for the pigtail. Standard lengths are as follows: 00.2 = 0.2 m, 00. = 0. m. Consult the factory for other cable length options. 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 1 ma C PA 66 M8 pigtail culus C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 1 ma C PA 66 cable, PUR 3 26 AWG Output current temperature curves.24

25 BMF 31 Cylinder & BMF 31 for welding applications or use up to 10 C Series Connection Type PNP Normally-open Rated operating field strength I H n I Assured operating field strength I Ha I Noise field strength max. Noise field frequency Hysteresis of I Hn I Temperature drift of turn-on point of I H n I On delay Off delay Supply voltage U B Voltage drop U d Rated insulation voltage Ui Rated operational current I e No-load supply current I 0 max. Off-state current Ir Protected against polarity reversal Short circuit protected Load capacity Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approvals Recommended Other cable length on request. BMF 31M Cable + M12 (S4) Rotating Threaded Connector max. 0.3 Nm Weld Field Immune BMF 31M-PS-W-2-S4-00,3 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 200 ka/m (200 Gauss) Hz 4 % 0.3 %/ C 0 ms 0 ms 4 V 20 ma C Al M12 pigtail culus C04 AEL-00-VY-00M BMF 31M Cable + M8 (S49) Rotating Threaded Connector max. 0.3 Nm Weld Field Immune BMF 31M-PS-W-2-S49-00,3 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 200 ka/m (200 Gauss) Hz 4 % 0.3 %/ C 0 ms 0 ms 4 V 20 ma C Al M8 pigtail culus C49 ANE-00-VY-00M Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper Wiring diagrams 6Connectors Normally-open Cable Connector Output current temperature curves 7Accessories o Product Overview t Technical Reference p Part Number Index

26 BMF 31 for welding applications or use up to 10 C BMF 31 Series Connection Type BMF 31M meter cable out BMF 31M Cable + M8 (S49) Rotating Threaded Connector BMF 31M meter cable out max. 0.3 Nm max. 0.3 Nm max. 0.3 Nm Weld Field Immune temperature rated temperature rated PNP Normally-open BMF 31M-PS-W-2-PU-0 BMF 31M-PS-D-2-SA3-S49-00,3 BMF 31M-PS-D-2-SA3-PU-0 Rated operating field strength I H n I Assured operating field strength I H a I Noise field strength max. Noise field frequency Hysteresis of I H n I Temperature drift of turn-on point of I H n I On delay Off delay Supply voltage U B Voltage drop U d Rated insulation voltage U i Rated operational current I e No-load supply current I 0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacity Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approvals Recommended 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 200 ka/m (200 Gauss) Hz 4 % 0.3 %/ C 0 ms 0 ms 4 V 20 ma C Al m cable, PUR 3 26 AWG culus 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 1 ma C Al M8 pigtail 3 culus C49 ANE-00-VY-00M 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4 % 0.3 %/ C 3.1 V 1 ma C Al m cable, PUR 3 26 AWG culus Other cable length on request. Wiring diagrams Normally-open Cable Output current temperature curves Connector.26

27 BMF 21 Cylinder & BMF 21 Series Connection Type BMF 21 The BMF 21 is designed with an integral swinging bracket arm that allows it to self-adjust across a wide range of cylinder diameters. This makes the BMF 21 ideal for the tie-rod and external rail profile cylinders. PNP NPN Rated operating field strength Hnl Assured operating field strength I H a I Hysteresis of I H n I Temperature drift of turn-on point of I Hn I Turn-on delay Turn-off delay Supply voltage UB Voltage drop U d Rated insulation voltage U i Rated operating current Ie No-load supply current I 0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range Ta LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended Normally-open Normally-open BMF 21 M08 DC Na Connector (S49) BMF 21K-PS-C-2-S49 BMF 21K-NS-C-2-S ka/m (1 Gauss) 2 ka/m (2 Gauss) 4% 0.3%/ C 0. ms 0. ms 3.1 V 30 ma 80 µa 1µF -2 C...+8 C PBT Hardened C49 ANE-00-VY-00M BMF 21 PuFlex Cable BMF 21K-PS-C-2-PU-* BMF 21K-NS-C-2-PU-* 1.2 ka/m (1 Gauss) 2 ka/m (2 Gauss) 4% 0.3%/ C 0. ms 0. ms 3.1 V 30 ma 80 µa 1µF -2 C...+8 C PBT Hardened cable, PUR 3 x 26 AWG Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position * Please specify the cable length for sensor. Standard lengths are as follows: 03 = 3 m, 0 = m. Consult the factory for other cable length options. Power Clamp & Gripper 6Connectors Wiring Diagram Output current temperature curve PNP/Connector NPN/Connector 7Accessories o Product Overview PNP/Cable NPN/Cable t Technical Reference p Part Number Index

28 BMF 21 BMF 21 BMF 21-HW-8 for pneumatic cylinders with tie rods Piston Ø = any Tie rod Ø mm or Pneumatic cylinders with DUO rail Piston Ø = any BMF 21-HW-10 BMF 21-HW-10E for pneumatic cylinders with tie rods Piston Ø mm Tie rod Ø mm or for pneumatic cylinders with integral tie rod (profile) Piston Ø mm Profile width mm BMF 21-HW-11 + Tube Cuff (SCHLAUCHSCHELLE BMF GR. ) for pneumatic cylinders without tie rods/rail Tube cuffs sold separately. Tube cuff sizes available for the following cylinder diameters: Pneumatic Tube Cuff Sizes Tube Cuff Size Piston Ø Cylinder Ø 0 < To order a combination kit of sensor with mounting bracket, include the bracket code in the part number. Example: BMF 21K/HW10-PS-2-C-S49.28

29 BMF 32 Cylinder & BMF 32 Series Connection Type BMF 32 The BMF 32's tough aluminum housing, compact size and rugged electronics make it the sensor of choice in tough industrial applications. The BMF 32 will perform where lesser devices call it quits. The BMF 32 is also available with a weld field immune circuit for demanding arc and reisistance welding applications. PNP Normally-open NPN Normally-open Rated operating field strength H nl Assured operating field strength I Ha I Hysteresis of I H n I Temperature drift of turn-on point of I H n I Turn-on delay Turn-off delay Supply voltage U B Voltage drop Ud Rated insualtion voltage U i Rated operating current I e No-load supply current I0 max. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 6029 Housing material Connection No. of wires gauge Approval Recommended BMF 32 M08 DC Na Connector (S49) BMF 32M-PS-C-2-S49 BMF 32M-NS-C-2-S ka/m ( 1 Gauss ) 2 ka/m ( 2 Gauss ) 4% 0.3%/ C 0.0 ms 0.0 ms 3.1V 30 ma 80 µf 1µF -2 C...+8 C IP67 Al C49 ANE-00-VY-00M To order a combination kit of sensor with mounting bracket, include the bracket code in the part number. Example: BMF 32M/HW12-PS-C-2-S49 BMF 32 M12 DC Micro Connector (S4) BMF 32M-PS-C-2-S4 BMF 32M-NS-C-2-S4 1.2 ka/m ( 1 Gauss ) 2 ka/m ( 2 Gauss ) 4% 0.3%/ C 0.0 ms 0.0 ms 3.1V 30 ma 80 µf 1µF -2 C...+8 C IP67 Al C04 AEL-00-VY-00M Wiring Diagrams PNP/Connector BMF 32 M12 DC Micro Connector (S4) Weld Field Immune NPN/Connector Weld Field Immune BMF 32M-PS-W-2-S4 BMF 32M-PS-W-2-S4 1.2 ka/m ( 1 Gauss ) 2 ka/m ( 2 Gauss ) 4% 0.3%/ C 0.0 ms 0.0 ms 4 V 30 ma 80 µf 0.1 µf -2 C...+8 C IP67 Al C04 AEL-00-VY-00M Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors BMF 32 fits 12mm wide, 60 trapezoidal channel or tie rods and rails with optional brackets. See following page for bracket options. Output current temperature curves 7Accessories o Product Overview t Technical Reference p Part Number Index.29

30 BMF 32 Brackets BMF 32 BMF 32-HW-12 for pneumatic cylinders with trapezoidal rail Mecman EUROMEC Piston Ø = any BMF 32-HW-13 for pneumatic cylinders with tension rod Piston Ø = any Tie rod Ø max. 11 mm BMF 32-HW-14 for pneumatic cylinders with trapezoidal rail Bosch types /31/32/33/ 34/3 Piston Ø = any BMF 32-HW-1 for pneumatic cylinders with tie rods Piston Ø = any Tie rod Ø mm BMF 32-HW-16 for pneumatic cylinders with duo rail or tie rods Piston Ø = any.30

31 BMF 32 Cylinder & BMF 32 BMF 32-HW-18 for pneumatic cylinders with trapzoidal rail SCHLAUCHSCHELLE BMF GR. for pneumatic cylinders without tie rods/rail Pneumatic Tube Cuff Sizes Tube Cuff Piston Ø Cylinder Ø Size 0 < Cylinder & BMF 32-HW-49 for small tie rod cylinders 3/4"-1 1/8" bore e.g. PHD A, AV, HV series Bracket is secured to tie rod and leverage holds sensor firmly in position BMF 32-HW-4 for tie rod cylinders up to 10 mm diameter tie rod Bracket is secured to tie rod and leverage holds sensor firmly in position O M4x0.7-6H Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 9.7 6Connectors Ø9.7 º Ø10.8 R Accessories o Product Overview t Technical Reference p Part Number Index

32 Prox Style Prox Style Housing type Connection type Housing size BMF 07M PuFlex-cable 6. O LED Some advantages of magnetic field sensors in the classic inductive sensor housing: Large sensing distances with small sizes Sensing through walls made of n-ferrous metals like aluminum, without reduced sensing distances Reacts only to magnetic fields; faulty switching by metal shavings or other metal parts Magnet can be flush mounted in steel Protected against polarity reversal Supply voltage Reacts to the rth or south poles Solid-state Wear-free Vibration insensitive Output protected against inductive peaks Short circuit protected PNP Normally-open NPN Normally-open Rated operating field strength Hn Assured operating field strength H a Differential travel Temperature drift Switch on response time Switch off response time Supply voltage UB Voltage drop U d at l e 100 ma Rated insulation voltage U i Rated operational current I e No-load supply current I 0 d./und. Off-state current I r Protected against polarity reversal Short circuit protected Load capacitance Ambient temperature range T a LED Degree of protection per IEC 29 Housing material Connection No. of wires size Approvals Recommended BMF 07M-PS-C-2-KPU-03 BMF 07M-NS-C-2-KPU ka/m (1 Gauss ) 2 ka/m (2 Gauss ) 4 % 0.3 %/ o C 3.1 V 22 ma/ 10 ma C nickel plated brass cable, PUR 3 x 26 AWG Wiring diagrams PNP/Cable PNP/Connector Output current temperature curves NPN/Cable NPN/Connector.32

33 Prox Style Cylinder & Prox Style Ø 6. mm, M8, M12 BMF 07M Cable + M8 (S49) Rotating Threaded Connector Ø 6. BMF 07M-PS-D-2-SA2-S49-00,3 BMF 07M-NS-D-2-SA2-S49-00,3 1.2 ka/m (1 Gauss ) 2 ka/m (2 Gauss ) 4 % 0.3 %/ o C 3.1 V 30 ma C nickel plated brass cable with, PUR culus C49 ANE-00-VY-00M BMF 07M Cable + M12 (S4) Rotating Threaded Connector Ø 6. BMF 07M-PS-D-2-S4-00,6 1,2 ka/m (1 Gauss ) 2 ka/m (2 Gauss ) 4 % 0.3 %/ o C 3.1 V 30 ma C nickel plated brass cable with, PUR culus C49 ANE-00-VY-00M BMF 08M PuFlex-cable 13 M8 M8x1 30. LED BMF 08M-PS-C-2-KPU-03 BMF 08M-NS-C-2-KPU ka/m (1 Gauss ) 2 ka/m ( 2 Gauss ) 4 % 0.3 % / o C 3.1 V 30 ma C nickel plated brass cable, PUR 3 26 AWG BMF 12M M12 DC Micro (S4) 17 M BMF 12M-PS-D-2-S4 BMF 12M-NS-D-2-S4 1.2 ka/m ( 1 Gauss ) 2 ka/m ( 2 Gauss ) 4 % 0.3 % / o C 3.1 V 12 ma/ 10 ma C nickel plated brass C04 AEL-00-VY-00M Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Operating Magnets Magnet type Samarium Cobalt Ferrite Strontium Ferrite Power Clamp & Gripper 6Connectors 7Accessories Ordering codes Nominal Dimensions Thickness Assured operating distance Sa Differential travel MAGNET PLATTE 16x12x mm 3 mm 28 mm 8 mm RUNDMAGNET 10.0x mm 10 mm 1 mm 2 mm RUNDMAGNET 4.0x.0 4 mm mm mm 2 mm o Product Overview t Technical Reference p Part Number Index

34 separation Installation Hints The response travel of a magnetic field sensitive sensor is virtually independent of the field strength of typical piston magnets. Still the sensor does t exhibit false switching. When using more than one of the magnetic field switches, the BMF sensors can be mounted directly next to or beside each other. Installation Adjustment and mounting 1. Set piston to end of travel. 2. Slide sensor (with power on) until the output turns on (LED on). Mark the location of the front edge of the sensor on the cylinder body. 3. Continue to slide the sensor until the output is off (LED off). 4. Change direction and slide the sensor back towards the other end of the cylinder. When output turns on, mark location of the same sensor edge (original front edge) on the cylinder body.. The two marks on the cylinder body define the width of the zone of the sensor with this cylinder. Determine the midpoint of the two marks and lock down the sensor so the original front edge is located at this midpoint..34 Use in weld fields Weld-immune magnetic field sensors can be operated in external fields up to a field strength of E max = 200 ka/m. This limit is often exceeded in the direct vicinity of high current lines, e. g. welding equipment. The sensor should therefore be mounted at a distance d min from such lines, as shown in the diagram at right showing the relationship between current and conductor diameter. Weld-immune sensors include: BMF 32M...W... BMF 30M...W... BMF 31M...W... BMF 30K...W...

35 Techlogy Cylinder & BMF Techlogy Comparison Operating principle Solid-state, wear-free operation Radio frequency immunity Required magnetic field strength Switching speed Contact bounce Susceptibility to damage by AC welding fields Susceptibility to false tripping by AC welding fields Works with magnet type Required magnetic polarity orientation BALLUFF Magnetoresistive (MR) Giant Magnetoresistive (GMR) Change of resistance/current Yes Moderate Low to high High No Low WFI versions, ne to low Hall Effect or Reed Magnet* MR Perpendicular or Parallel GMR Parallel BMF Techlogy Comparison Hall Effect Microvolt signal Yes Low High High No Low High Hall Effect Magnet only Perpendicular only Reed Switch Mechanical contact No High High Low Yes High High Reed Magnet only Parallel only Cylinder & Susceptible to double switchpoints Output short circuit protection Output reverse polarity protection Output overload protection Kw your cylinder? Find your sensor. No* Yes Yes Yes Yes Sometimes Sometimes Sometimes Yes No Yes (bipolar) *Always test in actual application. Some Hall Effect magnets will t trigger sensor reliably; others may cause double switch points. No It's that easy with Balluff's Pneumatic Cylinder Sensor Resource Center... - Over 1000 cylinders cataloged - Lifetime warranty on all solid state cylinder sensors Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

36 Precision in a compact housing BIL is the compact displacement sensor for position sensing up to 160 mm. The BIL analog position sensor utilizes n-contact magnetic inductive techlogy to provide continuous, absolute position feedback. BIL Analog Position Sensor Output signal U a Output signal I a Working range s a Linear range s I Voltage V or Current mA mm... mm BIL Features Power and magnet indicator LEDs (AMDO & EMDO) Magnet missing/out of range max output value indication (AMDO & EMDO) Non-contact Wear-free Suitable for harsh environments with potted sensor and electronics Processing electronics integrated, external components Housing cross-section 1 1 mm Applications Robotics/handling Clamping cylinders Packaging Process industry Position sensing on grippers Installation tes When installing and attaching the BIL and magnet, nmagnetizable materials such as alloys, austenitic steels, plastics, etc. are recommended. This applies both to the sensor as well as the magnet. Magnetizable materials can affect the geometry and strength of the field coming from the permanent magnet. Magnetic fields in the area of the BIL can, depending on their orientation and strength, affect the output signal. Ordering code 0-10 Vdc 0-10 Vdc / 4-20 ma Rated operational voltage U e Supply voltage U B Ripple Rated insulation voltage U i Rated sensing distance s e Load resistance R L No-load supply current I 0 at U e Protected against polarity reversal Short circuit protected Supply voltage indication Position marker inside/outside working range Ambient temperature range T a Repeat accuracy R BWN Non-linearity Limit frequency ( 3dB) Measuring speed Temperature coefficient TK typ. in the optimal range min. from C max. Degree of protection per IEC 6029 Housing material Connection Recommended Wiring diagrams BIL AMD0... t used BIL ED0 & EMD0... Connect to either voltage or current output. Recommended distances from magnetizable materials (for optimum function) BIL AMD0-T060A-01-S7 BIL EMD0-T060A-01-S Vdc 10 % of Ue 30 mm at Ua 2 kω, at Ia 00 Ω 30 ma (LED 1) (LED 2) C ±60 µm ±1 mm 100 Hz m/s + µm/k 20 µm/k +2 µm/k PA fiberglass reinforced C7A or C7B Output Curve l a U a BIL AMD0 & EMD all data in mm

37 BIL Sa mm, mm, V or ma distance "D" between magnet and sensor, see page.39 Voltage V or Current ma mm... mm BIL ED0-P060A-01-S7 at U a Vdc, at I a 10 % of Ue 30 mm at Ua 2 kω, at Ia 00 Ω 30 ma C ±60 µm ±0.6 mm 100 Hz m/s µm/k +1 µm/k 2 µm/k PA fiberglass reinforced C7A or C7B Output Curve BIL ED0... unusable area indexing slot 0 V voltage 10 V 4 ma current 20 ma unusable area distance "D" between magnet and sensor, see page.39 unusable area Voltage V or Current ma mm mm 0 V voltage 10 V 4 ma current 20 ma indexing slot BIL ED0-P160A-01-S7 at U a Vdc, at I a 10 % of Ue 80 mm at Ua 2 kω, at Ia 00 Ω 2 ma C ±80 µm ±2.4 mm 300 Hz m/s 40 µm/k +120 µm/k 200 µm/k PA fiberglass reinforced C7A or C7B unusable area Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview The original bracket and screws are recommended for mounting the BIL. Please order accessories separately. See page.39. t Technical Reference p Part Number Index.37

38 Output signal U a Output signal Ia Working range s a Linear range s I Micro-BIL For Analog Position Sensor Voltage V or current ma mm mm BIL 300 mm button Ordering code Field strength axial Hn 3dB width of axial field distribution, typical (axial field strength typ. parallel to ) Rated operational voltage Ue Supply voltage U B Ripple Rated insulation voltage Ui Rated sensing distance s e Load resistance R L No-load supply current I 0 at U e Protected against polarity reversal Short circuit protected Ambient temperature range T a Repeat accuracy R BWN Non-linearity Temperature coefficient TK typical in the optimal range min. from C max. Supply voltage indication Programming indication Degree of protection per IEC 6029 Housing material Connection Recommended BIL ED0-B010P-02/30-S7 10 ka/m typical 2. mm at U a Vdc, at I a 10 % of U e mm at U a 2 kω, at I a 00 Ω 30 ma C ±30 µm ±0.3 mm +4 µm/k +2 µm/k +10 µm/k PA fiberglass reinforced C7A or C7B Wiring diagram V output ma output Connect to either voltage or current output. Micro-BIL is the solution for continuous position sensing on pneumatic miniature grippers with T-slot. The analog output signal allows you to sense end-of-travel and intermediate positions of gripper jaws absolutely and without contact. To use the Micro-BIL a magnet is installed in the gripper. A button is provided for calibrating to various magnetic field strengths. The technical data refers to reference measurements. Different grippers with differing magnetic field strengths may affect the technical data. Output curve.38

39 BIL Cylinder & BIL Accessories Description Dimensions Material Distance "D" Ordering code Description Material Magnet Hard ferrite 2 mm BIL 000-MH-A Bracket stainless steel Magnet PA fiberglass reinforced 1 mm BIL 001-MH-A Bracket stainless steel Analog Set Point Controller M18 1 CuZn nickel plated C7 ENL-04-VY-003M BES _S-1-PU-0 Analog output PNP or NPN rmally- open Input signal V Resolution 8 bits 3 binary switch points Teach-in programming See page 7.34 for technical information Bracket stainless steel Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper Ordering code BIL 01-HW-1 BIL 01-HW-2 BIL 01-HW-3 6Connectors Installation Examples 7Accessories o Product Overview t Technical Reference p Part Number Index

40 .40 Cylinder &

41 Inductive Cylinder Balluff s cylinder-position sensors provide precision end-of-stroke sensing for hydraulic cylinders. The sensor body allows 304 of rotation to eliminate the hassle of postinstallation cable management, which in some competitive designs requires unbolting the flange and breaking the hydraulic seal. A high-pressure, inductive proximity sensor, the Strokemaster provides a 2mm (0.08") sensing range to detect the spud of hydraulic/ pneumatic cylinders and indicate fully retracted or extended position. It mounts with two socket-head cap screws and seals with a Viton O-ring. Withstanding cylinder pressures up to 3000 PSI (207 bar), the embeddable design keeps most of the switch protected within the cylinder, with only a 0.62" (16 mm) high housing exposed outside. Strokemaster sensors are available in 3-wire DC and 2-wire AC/DC versions, both with mini or micro s. Switching frequency is 0 Hz for the AC/DC versions. All units are weld-field immune, short-circuit, and reversepolarity protected. They fit all popular cylinder designs, with standard available probe lengths of 0.912" " (23.16mm mm). Custom probe lengths can be achieved by using factory spacer kits. Probes are made of stainless steel with a high-strength ceramic face. Both DC and AC/DC sensors have all-metal housings. The Strokemaster sensor is CE-certified, and its housing is sealed to IP67 requirements..42 DC.43 AC/DC.44 Technical Information Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

42 DC s n 2 mm Rated operating distance s n Assured operating distance s a Flush 2 mm mm PNP Normally-open! Rated operational voltage U e Supply voltage U B Voltage drop U d at l e Rated insulation voltage U i Rated operational current I e No-load supply current I 0 damped/undamped Off-state current I r Protected against polarity reversal Short circuit/overload protected Load capacitance Repeat accuracy R Ambient temperature range Ta Operating frequency f Utilization categories Function/Operating voltage indication Degree of protection per IEC 6029 Housing material Material of sensing face Connection Approvals High pressure rated up to Standard lengths (L) Recommended BES S 29/0.912" "-S4 2. V 18 ma/ 10 ma / 1.0 µf % C 10 Hz DC 13 / stainless steel/aluminum ceramic micro culus 207 bar (3000 psi) see table on page.44 C04 AEL-00-VY-00M Bolt sensor to cylinder. Position cable to desired orientation (even over mounting bolts). Lock chosen position with one or both of the two integral set screws. Note: Some DC units are also available with S Mini. Consult factory for sensor and cable part numbers..42

43 AC/DC s n 2 mm Rated operating distance s n Assured operating distance sa AC/DC Wiring Diagrams! 30 PNP N/O AC/DC N/O w/ Gnd. 1 GRN RD/BLK RD/WH LED 1 LED 2 Normally-open Rated operational voltage Ue Supply voltage U B Voltage drop U d at l e Rated insulation voltage Ui Rated operational current I e Minimum operational current I m Off-state current Ir Inrush current I k (t = 20 ms) Protected against polarity reversal Short circuit protected Repeat accuracy R Ambient temperature range T a Operating frequency f Utilization categories Function/Operating voltage indication Degree of protection per IEC 6029 Insulation class Housing material Material of sensing face Connection Approvals High pressure rated up to Standard lengths (L) Recommended Flush 2 mm mm BES S 2/0.912" "-S Vac Vac/Vdc 6 V 20 Vac 00 ma ma 1.7 ma at 110 Vac 3 A max./1 Hz % C 0 Hz AC 140/DC 13 / 1 stainless steel/aluminum ceramic micro culus 207 bar (3000 psi) see table on page.44 C21 AE3-00-VY-10F Flush 2 mm mm UNC 1/4-20x3/ UNC 1/4-20x3/ O-ring X 2.62 O-ring X 2.62 ½ UNF-20-2A 7/8-16 UN 7 O12.7 L L O12.7 BES S 2/0.912" "-S 110 Vac Vac/Vdc 6 V 20 Vac 00 ma ma 1.7 ma at 110 Vac 3 A max./1 Hz % C 0 Hz AC 140/DC 13 / 1 stainless steel/aluminum ceramic mini culus 207 bar (3000 psi) see table on page.44 C0 AE1-00-VY-10F 64.2 Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

44 Installation & Spacers Installation Note: Spacer may be required to elevate cylinder sensor to position sensing face in optimal position. Balluff recommends the following guidelines when mounting our sensors: A - Recommended to allow for Spacers mechanical wear (0.02" to 0.047") B - This dimension must be large eugh to allow the sensor to turn off when the rod is present (0.110" to 0.118") Probe length (inches) Below is a table to help you pick out a spacer for custom lengths needed with sensors: Z/Spacers (inches) Example: Need probe length of 1.12" combine sensor BES S2-1.3-S21 with a 0.22" spacer. (1.3" tube length " spacer = 1.12" adjusted length) Note: A difference of 0.00" will still have to be carefully considered when sizing a spacer and sensor to the cylinder. - Spacer kits include a spacer, "O" ring, and appropriate mounting screws. - Other spacer kits may be available: consult factory. To order a spacer kit: Use part number BESA KIT-* (X.XXX) *measured in inches (For both DC and AC/DC devices - there is difference in flange dimensions).44

45 Cylinder & Introduction Inductive Cylinder Balluff offers a world-class line of pressurerated inductive cylinder sensors to service high pressure applications. Designed to withstand severe duty, Balluff high pressure sensors deliver reliable switching performance under demanding industrial conditions. Corrosion-resistant housing materials, highstrength ceramic sensing faces, and special sealing techniques allow dependable service up to 30 bar or 00 bar according to the sensor type. All Balluff high pressure sensors are rated for continuous operation in ambient temperatures up to 90 C, with some versions also hightemperature rated up to 120 C..46 DC 3-wire M8, M12.48 DC 3-wire M16.49 DC 3-wire M18.0 Extended Temperature DC 3-wire M12, M18.1 Extended Range M12.2 Power Clamp & Gripper Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper of Pressure Rated with O-Ring d1: of bore for switch head, 10 H8 = d2: minal thread diameter, 6H L: recommended insertion depth L 0.8 d2 H8 Note: To ensure sealing under extremely high pressure, the sensors are supplied with an O-ring and a PTFE supporting ring. The 1 to 30 chamber is required to avoid damage to the O-ring when the sensor is inserted. thread undercut D DIN 76 6H 0.6 O-ring-cord diameter assembly direction 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

46 DC 3-Wire M8, M12 S n 1. mm Housing size Rated operating distance s n Assured operating distance s a M8 1 flush 1. mm mm M12 1 flush 1. mm mm M12 1 flush 1. mm mm M12 1 flush 1. mm mm O-Ring 12.9 O-Ring 12.9 O-Ring PNP Normally-open! BES S289-BO-D-PU-0 BES S292-BO-D-PU-0 BES S162-S4-D BES S163-S4-D BES S164-S4-D NPN Normally-open $ BES S242-S4-D Rated operational voltage U e Supply voltage U B Voltage drop U d at l e Rated insulation voltage U i Rated operational current I e No-load supply current I0 d./und. Off-state current I r Protected against polarity reversal Short circuit/overload protected Load capacitance Repeat accuracy R Ambient temperature range Ta Operating frequency f Utilization categories Function indication Degree of protection per IEC 6029 Housing material Material of sensing face Connection No. of wires gauge High pressure rated up to Recommended Vdc 1 V 10 ma 0 µa 0.2 µf 1 % C 6000 Hz DC 13 stainless steel ceramic cable 3 x 26 AWG 100 bar (140 psi) 2 V 10 ma/ 2 ma / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M 1. V 8 ma/ 1 ma / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M 1. V 20 ma/ 12 ma / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M Other cable lengths may be available. Additional models may exist. Replacement o-rings and support rings are also available. Consult factory or company website for details. Accessory seal nut: BES 08-DM-1 (see page 7.13) O10e O10e O10e PNP N/O PNP N/C PNP N/O & # NPN N/O NPN N/C NPN N/O & N/C $ % ^.46

47 Cylinder & DC 3-Wire M12 S n 1. mm M12 1 flush 1. mm mm BES S281-S4-D O-Ring 17 M12 1 flush 1. mm mm BES S26-S4-D M12 1 flush 1. mm mm BES S240-D-PU-0 BES S241-D-PU-0 M12 1 flush 1. mm mm BES S249-S4-D M12 1 flush 1. mm mm BES S13-S4-D Cylinder & 1. V 130 ma 2 ma/ 1 ma / 1.0 µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M 2.0 V 10 ma/ 2 ma / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M O10e V 20 ma/ 12 ma 10 µa / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP cable 3 24 AWG 00 bar (7200 psi) 2.0 V 10 ma/ 2 ma 10 µa / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M O10e V 10 ma/ 1 ma 10 µa / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M O10e Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

48 DC 3-Wire M12, M16 S n 1. mm Housing size Rated operating distance s n Assured operating distance s a M12 1 flush 1. mm mm M12 1 flush 1. mm mm M12 1 flush 1. mm mm M16 1 flush 1. mm mm M16x1 O14e7 O-Ring O-Ring Ø1 14 PNP Normally-open! BES S20-D-PU-0 BES S262-S4-D BES S13-D-PU-0 BES S178-D-PU-0 BES S12-S4-D Rated operational voltage U e Supply voltage U B Voltage drop U d at l e Rated insulation voltage U i Rated operational current Ie No-load supply current I 0 d./und. Off-state current I r Protected against polarity reversal Short circuit/overload protected Load capacitance Repeat accuracy R Ambient temperature range T a Operating frequency f Utilization categories Function indication Degree of protection per IEC 6029 Housing material Material of sensing face Connection No. of wires gauge High pressure rated up to Recommended Other cable lengths may be available. Additional models may exist. Replacement o-rings and support rings are also available. Consult factory or company website for details. 2.0 V 10 ma/ 2 ma 10 µa / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP cable 3 24 AWG 30 bar (000 psi) O10e V 10 ma/ 2 ma 10 µa / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP 00 bar (720 psi) C04 AEL-00-VY-00M O10e V 10 ma 10 µa 0. µf % C 1000 Hz DC 13 IP 68 stainless steel EP cable, PUR 3 x 26 AWG 00 bar (720 psi) 1. V 8 ma/ 1 ma 10 µa / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 30 bar (000 psi) C04 AEL-00-VY-00M M16x1 O14e7 PNP N/O PNP N/C PNP N/O & # NPN N/O NPN N/C NPN N/O & N/C $ % ^.48

49 Cylinder & DC 3-Wire M16, M18, Ø 10 mm, Ø 36 mm S n 1. mm, 3 mm O-Ring 22 M16 1 flush 1. mm mm 14 M16x1 O14e BES S149-S4-D BES S16-S4-D O-Ring M18 1 flush 1. mm mm M18x1 O14e7 13 M20 8 BES S144-S4-D 73 M18 1 flush 3 mm mm BES S190-S4 Ø 10 mm/ø 36 mm flush 1. mm mm BES S260-S4-D Cylinder & 1. V 1 ma/ 12 ma 10 µa / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 30 bar (000 psi) C04 AEL-00-VY-00M M16x1 O14e V 8 ma/ 1 ma 10 µa / 0. µf % C 1000 Hz DC 13 IP 68 stainless 430F EP 30 bar (000 psi) C04 AEL-00-VY-00M M18x1 O14e V 130 ma 2 ma/ 12 ma / 1.0 µf % C 400 Hz DC 13 IP 68 stainless 430F PEEK 00 bar (720 psi) C04 AEL-00-VY-00M 2.0 V 10 ma/ 2 ma 10 µa / 1.0 µf % C 2000 Hz DC 13 IP 68 stainless 430F EP 30 bar (000 psi) C04 AEL-00-VY-00M 3.8 Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

50 DC-3 Wire M12, M18 s n 1. mm Extended Duty Housing size Rated operating distance s n Assured operating distance s a M12 1 flush 1. mm mm M12 1 flush 1. mm mm M18 1 flush 1. mm mm Ø10e7 Ø10e7 O-Ring O-Ring O-Ring Extended Temperature Extended Temperature Extended Temperature PNP Normally-open! BHS B13V-PSD1-S04 BHS B249V-PSD1-S04 BHS E308V-PSD1-S04 Rated operational voltage U e Supply voltage U B Voltage drop U d at l e Rated insulation voltage U i Rated operational current I e No-load supply current I 0 d./und. Off-state current I r Protected against polarity reversal Short circuit/overload protected Load capacitance Repeat accuracy R Ambient temperature range Ta Operating frequency f Utilization categories Function indication Degree of protection per IEC 6029 Housing material Material of sensing face Connection No. of wires gauge High pressure rated up to Recommended 2. V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic 00 bar (720 psi) C04 AEL-00-VY-00M 2. V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic 00 bar (720 psi) C04 AEL-00-VY-00M 2. V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic 00 bar (720 psi) C04 AEL-00-VY-00M Extended Temperature Models Provide high pressure rating of 00 bar Allow use in higher ambient temperature environments up to 120 C! PNP N/O.0

51 Extended Duty Cylinder & DC-3 Wire M12 s n 2. mm O-Ring M12 1 flush 2. mm mm Ø10e Extended Range BHS B13V-PSD2-S V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic bar (720 psi) C04 AEL-00-VY-00M O-Ring M12 1 flush 2. mm mm Ø10e Extended Range BHS B249V-PSD2-S V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic 00 bar (720 psi) C04 AEL-00-VY-00M O-Ring M12 1 flush 2. mm mm Ø10e Extended Range BHS B26V-PSD2-S V 8 ma 10 µa 0. µf % C 400 Hz DC 13 IP 68 stainless steel ceramic 6 00 bar (720 psi) C04 AEL-00-VY-00M Simulation (FEM method) of the stress distribution under high pressure on housing and ceramic cap Extended Range Models Provide extended sensing ranges of 2. mm High pressure rated to 00 bar Temperature rated to +90 C Cylinder & Selection Guide Magnetic Field BMF 103 BMF 273 BMF 303 BMF 30 BMF 307 BMF 31 BMF 21 BMF 32 BMF Prox Style Installation/ BIL Magneto- Inductive Cylinder Position Power Clamp & Gripper 6Connectors 7Accessories o Product Overview t Technical Reference p Part Number Index

52 Power Clamp & Gripper Clamp & Gripper Description Rated operating distance s n The Power Clamp & Gripper Large Sensing Coils 2 mm Small Sensing Coils 2 mm Small Sensing Coils 2 mm These sensors are specifically designed for use in power clamp and gripper applications. These devices incorporate two sensors into one unit, reducing the number of sensors and connection systems required for applications. Each sensor has two sensing coils (chicklets) that are used to detect whether the clamp/ gripper is in the open or closed position. 20 Cable length LED 1 LED 2 LED The base has a compatible mounting configuration for the cartridges used by the major clamp manufacturers. PNP N/O BES Z02KR2-PSC20F-P*-S04-V BES Z02KR1-PSC20F-P*-S04-V BES Z02KR3-PSC20F-P100-S04-V Rated operational voltage Load current Leakage current Voltage drop Repeatability Hysteresis Pulse protection Noise protection Short circuit protection Overload protection Weld field immunity Approvals Protection class Housing material Material of sensing face Cable material Operating temperature LED Connector * Cable lengths are: * P100 = 100 mm * P16 = 16 mm * P200 = 200 mm 10 ma 10 ma 2. V 2 % % 1600 Gauss culus, CE plastic plastic PUR C Gn = PWR, Org = S1, Rd = S2 C04 AEL-00-VY-00M 10 ma 10 ma 2. V 2 % % 1600 Gauss culus, CE plastic plastic PUR C Gn = PWR, Org = S1, Rd = S2 C04 AEL-00-VY-00M 10 ma 10 ma 2. V 2 % % 1600 Gauss culus, CE plastic plastic PUR C Gn = PWR, Org = S1, Rd = S2 C04 AEL-00-VY-00M Features Superior LED visibility Weld-field immune Shielded construction Short circuit protection Overload protection Transient ise protection False pulse protection Reverse polarity protection culus and CE certified.2

Normally-open. Normally-open

Normally-open. Normally-open Series BMF 07 Series BMF 07 BMF 07 PNP Normally-open BMF 07K-PS-C--S49- BMF 07K-PS-C-- Non-contact, wear-free piston sensing Insensitive to contamination Piston sensed through the cylinder wall Can be

More information

Sensors for Pneumatic Cylinders. Product overview for BMF magnetic field sensors

Sensors for Pneumatic Cylinders. Product overview for BMF magnetic field sensors Sensors for Pneumatic Cylinders Product overview for BMF magnetic field sensors Sensors for Pneumatic Cylinders Magnetic field sensors Increase function reliability and uptime for your machines Better

More information

Magnetic Cylinder Sensors with Mounting System

Magnetic Cylinder Sensors with Mounting System Cylinder Sensors Contents mounting system 858 mounting brackets 860 862 mounting brackets 864 866 mounting brackets 868 872 mounting brackets 873 Know your? Find your sensor at www.balluff.us/bmfcenter

More information

Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic.

Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic. Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic. Magnetic sensors, cylinder sensors www.ifm.com/gb/cylindersensors fluid sensors and diagnostic systems position

More information

Inductive Special Properties

Inductive Special Properties Contents pressue high pressure NAMUR magnetic weld immune temperature extended Special Properties sensors special mechanical and/or electrical properties. Use under extremely harsh conditions Resistant

More information

Table of Contents. SH Series Linear Slides

Table of Contents. SH Series Linear Slides Table of Contents SH Series...3-17 Features and Benefits... 3 How To Order... 4 Dimensions...5-7 Specifications and Load Ratings....8-10 Mounting Options... 11 NuMate Mounting System.... 12 Multi-Position

More information

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co. Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard, custom developed products and application components, have made a significant

More information

MAGNETO-INDUCTIVE POSITION DETECTORS

MAGNETO-INDUCTIVE POSITION DETECTORS MAGNETO-INDUCTIVE POSITION DETECTORS Series 88 Type 2 wires APPLICATION This four-wire proximity sensor will monitor stroke end and intermediate positions of pneumatic cylinders equipped with built-in

More information

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432 Pneumatic cylinders, piston-ø 25 mm Single acting DIN ISO 6432 Technical data for series HE Order code HE-16-025 Series Piston-Ø Stroke length (mm) Design and function Single acting pneumatic cylinder

More information

Proximity sensors SMT/SME-10, for C-slot

Proximity sensors SMT/SME-10, for C-slot Proximity sensors SMT/SME-10, for C-slot Proximity sensors SMT/SME Product range overview Design Type of mounting Measuring principle Type Operating voltage range For C-slot Standard Insertable in slot

More information

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line ISO/VDMA Series ISO 6431 and VDMA 24562 Cylinder Line www.asco.com Table of Contents ISO/VDMA Series Features and Benefits 2 How to Order 3 Technical Information 4 Dimensions Tie-Rod Version 5 Mounting

More information

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552 Pneumatic cylinders, piston-ø 32 100 mm Double acting with magnetic piston DIN ISO 15552 Technical data for series SL 050 450 Order code SL-032-0250-050 Series Piston-Ø Stroke length (mm) Type of cylinder

More information

Innovation in pressure sensing Simple-to-set compact electronic pressure switches. Pressure switches

Innovation in pressure sensing Simple-to-set compact electronic pressure switches. Pressure switches Innovation in pressure sensing Simple-to-set compact electronic es Pressure switches PK es with mechanical adjustment dials provide simple setup Extremely durable The PK features a 316 stainless steel

More information

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm Compact cylinders series NYD Double acting with magnetic piston, ISO 21287 M5 to G1/8 Piston Ø 20 to 100 mm 200, 210 220 600, 610 620 Order code NYD-032-125-210 High force cylinder series NYDK and multiple

More information

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line ISO 6431 and VDMA Cylinder Line w w w. n u m a t i c s. c o m

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line ISO 6431 and VDMA Cylinder Line w w w. n u m a t i c s. c o m ISO/VDMA Series ISO 6431 and VDMA 24562 Line Cylinder Line ISO 6431 andcylinder VDMA 24562 w w w. n u m a t i c s. c o m Table of Contents ISO/VDMA Series Features and Benefits 3 How to Order 4 Technical

More information

CPLab / CP Factory. Application module magazine. Data sheets

CPLab / CP Factory. Application module magazine. Data sheets CPLab / CP Factory Application module magazine Data sheets Data sheet: Push-in fitting QSM-M5-4 #153304 Size Mini Nominal size 2.2 mm Type of seal on screw-in stud Sealing ring Container size 10 Design

More information

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors MH-Series Mobile Hydraulic in-cylinder Sensor Model MH Analog Output Data Sheet SENSORS Document Part Number 550824 Revision

More information

SMART STOP TM WELKER SMART STOP DOES ALL STOPPING & SENSING FUNCTIONS IN ONE PART. MINIMIZES ENGINEERING, FIELD SET UP AND OPERATOR ADJUSTMENT TIME.

SMART STOP TM WELKER SMART STOP DOES ALL STOPPING & SENSING FUNCTIONS IN ONE PART. MINIMIZES ENGINEERING, FIELD SET UP AND OPERATOR ADJUSTMENT TIME. ISO 9001 REGISTERED SMART STOP TM TM WELKER SMART STOP DOES ALL STOPPING & SENSING FUNCTIONS IN ONE PART. MINIMIZES ENGINEERING, FIELD SET UP AND OPERATOR ADJUSTMENT TIME. ELIMINATES: n NEED FOR SEPARATE

More information

More Precision. mainsensor Magneto-inductive displacement sensor

More Precision. mainsensor Magneto-inductive displacement sensor More Precision mainsensor Magneto-inductive displacement sensor mainsensor Magneto-inductive sensors for non-contact linear displacement measurement Measuring principle mainsensor is based on an innovative

More information

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA > Series CST-CSV-CSH proximity switches Series CST - CSV and CSH magnetic proximity switches Reed, Electronic» Designed to fit into the grooves provided in the profile barrel of the cylinder» The three

More information

The Latest Sensor Trends

The Latest Sensor Trends Sensing & Feedback Technologies The Latest Sensor Trends Agenda Miniature sensors open up new applications Alternatives to Fiber optics Pneumatic cylinder sensing: Dual systems, analog and lifetime warranties

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm Temposonics Absolute, Non-Contact Positions Sensors M-Series Document Part Number 551218 Revision D Temposonics MT Measuring length 50-1500 mm Redundant Sensor for Mobile Hydraulics Redundant Sensor System

More information

SERIES PA SWING ARM CLAMPS for the Automotive Industry

SERIES PA SWING ARM CLAMPS for the Automotive Industry Pa SERIES PA SWING ARM CLAMPS for the Automotive Industry Ideal for a wide variety of automated part holding and transfer applications Copper Arm Switches Installed ORDERING DATA: SERIES PA CLAMPS INDEX:

More information

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Complete modular designed accessory program More for less - optimal configuration costs Easy maintenance and commissioning

More information

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-RS4

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-RS4 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible Fine adjustment tool and stopper directly mountable on the

More information

AG Series Angular Grippers

AG Series Angular Grippers AG Series Angular Grippers www.numatics.com Table of Contents AG Series Angular Grippers Features and Benefits 3 How to Order 4 Dimensions 5 Specifications and Load Ratings 6 Sensing Part Numbers 7 Quick

More information

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics Temposonics Absolute, Non-Contact Position Sensors M-Series Temposonics MH Measuring length 50-2500 mm Compact Sensor for Mobile Hydraulics Linear, Absolute Measurement in Hydraulic Cylinders Contactless

More information

Linear actuators DFPI

Linear actuators DFPI Linear actuators DFPI Linear actuators DFPI Key features General information Linear actuator for actuating process valves such as gate valves and shut-off valves in process automation systems Linear actuator

More information

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05 Pressure transmitter Type Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement

More information

Climax Pneumatics. ISO 6432 Interchangeable Cylinders Easley, South Carolina

Climax Pneumatics. ISO 6432 Interchangeable Cylinders Easley, South Carolina Climax Pneumatics ISO 6432 Interchangeable Cylinders 1-800-732-8704 Easley, South Carolina End Caps Anodized Aluminum Tube Stainless Steel AISI 304 Piston Seals Rod Bushing Brass ø 8-10 - 12 Polyurethane

More information

GRB. long life Compact Angular gripper SHIPS IN 1-2 days. Major Benefits. Industry Uses

GRB. long life Compact Angular gripper SHIPS IN 1-2 days. Major Benefits. Industry Uses long life Compact Angular gripper SHIPS IN 1-2 days hardened steel jaws have robust design and include dowel holes for precise tooling location steel cover, jaw design, and tight jaw slots minimize external

More information

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety Temposonics Magnetostrictive Position Sensors m SENSORS G-Series Redundant Temposonics GT2 and GT3 Measuring length 25-1500 mm Redundancy for enhanced safety Up to 3 totally separated, independent measuring

More information

Sensors for Fluid Technology.... refi ned quality for optimal products

Sensors for Fluid Technology.... refi ned quality for optimal products Sensors for Fluid Technology... refi ned quality for optimal products BMF/BIL Sensors for Pneumatic Cylinders BAW Inductive Distance Sensors Valve position feedback, soft stopping Magneto-inductive Position

More information

MPS Series Proximity Switches

MPS Series Proximity Switches MPS Series Proximity Switches User Manual Shanghai Yuanben Tech. Co., Ltd. No. 605-10, Jiaan Rd. Jiading Shanghai Shanghai, China (201821) Tel: 086-21-6918301 Fax: 086-21-69168673 Email: postmaster@yuanben.cn

More information

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD ATEX category II 3 G, Ex zone 2 ATEX category II 3 D, Ex zone 22 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible

More information

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors MH-Series Model MB Mobile Hydraulic Sensor with Analog Output Data Sheet SENSORS Document Part Number 551284 Revision A MH-Series

More information

Electronic Sensors Solid State, Reed and Proximity Sensors Feedback Packages

Electronic Sensors Solid State, Reed and Proximity Sensors Feedback Packages Electronic Solid State, Reed and Proximity Feedback Packages & Feedback Contents Hall Effect... 2 Reed Switches... 3 Cordsets... 4 Proximity... 5 Feedback Packages... 8 1 Sensor Specifications Solid State

More information

DB4 GUIDED SLIDE APPLICATIONS: ISO 9001 REGISTERED RETRACTABLE PINS & LOCATORS PUSHERS CROWDERS THRUSTERS SMALL LIFTERS SLIDES

DB4 GUIDED SLIDE APPLICATIONS: ISO 9001 REGISTERED RETRACTABLE PINS & LOCATORS PUSHERS CROWDERS THRUSTERS SMALL LIFTERS SLIDES ISO 9001 REGISTERED DB4 GUIDED SLIDE 1/4" NPT or G1/4 PORTS RAP OR RIGID COUPLER TOOL MOUNTING SURFACE WELKER 70mm BORE PNEUMATIC CYLINDER SOLID STATE CYLINDER SWITCH NAAMS STOPS OR WELKER SMART STOPS

More information

Table of Contents. ISO/VDMA Series

Table of Contents. ISO/VDMA Series Table of Contents ISO/VDMA Series...3-22 Features and Benefits... 3 How to Order.... Technical Information... 5 Dimensions Profile Version...6-7 Tie-Rod Version...8-9 Mounting Parts...-16 Switches... 17

More information

5 mm contact pin pitch PCB or 95 series sockets

5 mm contact pin pitch PCB or 95 series sockets 1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket

More information

WBG Series Wide Body Grippers

WBG Series Wide Body Grippers WBG Series Wide Body Grippers www.numatics.com Table of Contents WBG Series Parallel Grippers Features and Benefits 3 How To Order 3 WBGS 60 Dimensions & Technical 4 WBGS 90 Dimensions & Technical 5 WBGL

More information

INTEGRATED HYDRAULIC BRAKE ACTUATORS

INTEGRATED HYDRAULIC BRAKE ACTUATORS INTEGRATED HYDRAULIC BRAKE INTEGRATED HYDRAULIC BRAKE INTEGRATED HYDRAULIC BRAKE The integrated hydraulic brake is comprised of a pneumatic cylinder that acts as an actuator and an oleo-dynamic circuit

More information

3RG4 BERO Inductive Proximity Switches

3RG4 BERO Inductive Proximity Switches 3RG40 11 3RG40 11 0AA00 10/14 3RG40 11 0AB00 10/14 3RG40 11 0AF00 10/13 3RG40 11 0AF05 10/18 3RG40 11 0AF33 10/17 3RG40 11 0AG00 10/13 3RG40 11 0AG05 10/18 3RG40 11 0AG33 10/17 3RG40 11 0CC00 10/14 3RG40

More information

Electronic pressure switch with two switching outputs

Electronic pressure switch with two switching outputs Electronic pressure switch with two switching outputs RE 30278/04.14 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /2/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code 2

More information

PRODUCT CATALOG COMPACT HYDRAULIC SPACE-SAVING, LONG-LASTING DEVICES FOR DEMANDING DESIGN REQUIREMENTS.

PRODUCT CATALOG COMPACT HYDRAULIC SPACE-SAVING, LONG-LASTING DEVICES FOR DEMANDING DESIGN REQUIREMENTS. PRODUCT CATALOG COMPACT HYDRAULIC SPACE-SAVING, LONG-LASTING DEVICES FOR DEMANDING DESIGN REQUIREMENTS. TABLE OF CONTENTS 3 Compact Hydraulic 4 Product Features 4 Features and Benefits 5 How to Order 6

More information

Table of Contents ISO

Table of Contents ISO Table of Contents ISO 6432...3-12 Features and Benefits...3 How to Order....4 Dimensions Single Rod End, Single and Double Acting...5 Single and Double Acting-Double Rod...6 Mounting Accessories...7-10

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS Temposonics Magnetostrictive Position Sensors m SENSORS M-Series Temposonics MH Measuring length 50-2500 mm Compact Sensor for Mobile Hydraulics Linear, Absolute Measurement in Hydraulic Cylinders Contactless

More information

E Series Economic Tie-Rod Cylinder Line

E Series Economic Tie-Rod Cylinder Line Series Economic Tie-Rod Cylinder Line www.numatics.com Table of Contents E Series Features and Benefits 3 How to Order 4 Basic E-Series Cylinders 5 Cushioned Cylinders 5 Basic E-Series Dimensions 5 E-Series

More information

Universal Magnetic Field Sensors

Universal Magnetic Field Sensors Universal Magnetic Field Sensors www.turck.com The BIM-UNT, a universal magnetic field sensor, is the latest addition to the inductive-magnetic family of switches by TURCK. It has the ability to detect

More information

E Series Economic Tie-Rod Cylinder Line

E Series Economic Tie-Rod Cylinder Line E Series Economic Tie-Rod Cylinder Line w w w. n u m a t i c s. c o m Table of Contents E Series Features and Benefits 3 How to Order 4 Basic E-Series Cylinders 5 Cushioned Cylinders 5 Basic E-Series Dimensions

More information

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb) Mounting TURCK inductive proximity sensors are manufactured with a shielded coil, designated by Bi in the part number, and a nonshielded coil, designated by Ni in the part number (See page C7). Embeddable

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display

More information

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm Temposonics Absolute, Non-Contact Position Sensors M-Series / SIL2* Temposonics MH Measuring Length 50-2500 mm Compact Sensor for Mobile Hydraulics Linear, absolute Measurement in Hydraulic Cylinders Non-Contact

More information

PNEUMATIC 180 ANGULAR GRIPPER

PNEUMATIC 180 ANGULAR GRIPPER PNEUMATIC 180 ANGULAR GRIPPER Major Benefits Jaws rotate completely clear of work area eliminating an otherwise required axis of travel Three standard jaw rotations available: 60, 90, and 180 One piece

More information

Allen-Bradley Parts. Contents. Inductive Proximity Sensors

Allen-Bradley Parts. Contents. Inductive Proximity Sensors Contents General Information Quick Selection Guide....................... page 2 2 Technical Definitions and Terminology......... page 2 5 Introduction................................ page 2 7 Applications...............................

More information

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors M-Series Mobile Hydraulic in-cylinder Sensor Model MH CANopen, CAN J1939 Output Data Sheet SENSORS Document Part Number 551027

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Operating pressure: -4.5-74 psi electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display Units displayed Switching logic Ambient

More information

PMS - PKS / PMW - PKW series

PMS - PKS / PMW - PKW series features / series warranty warranty Innovative housing (double enclosure) Cutting oils resistant (for machines tool) Immersion proof (sealing IP 67/68) High frequency switching Complementary output (NO+NC),

More information

ACTUATORS POSITION SENSOR

ACTUATORS POSITION SENSOR POSITION SENSOR 1 2 SUMMARY P INTRODUCTION PAGE 4 P LTS POSITION SENSOR PAGE 5 P LTL POSITION SENSOR PAGE 9 SUMMARY P LTE POSITION SENSOR PAGE 12 3 INTRODUCTION INTRODUCTION Magnetic position sensors are

More information

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power

More information

40 Series - Miniature PCB relays A. Features

40 Series - Miniature PCB relays A. Features 1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole

More information

Climax Pneumatics Cnomo NFE Cylinders

Climax Pneumatics Cnomo NFE Cylinders Climax Pneumatics Cnomo NFE 49001 Cylinders End Caps Tube Tie Rods Seals Piston Rod Diecast Aluminum Anodized Aluminum Zinc Coated or Stainless Steel Polyurethane Chromium Coated Steel Working Pressure

More information

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater T E M P O S O N I C S I I I ANALOG P r o d u c t S p e c i f i c a t i o n s F e a t u r e s Superior resolution and repeatability Absolute displacement and velocity measurement Modular, non-contacting

More information

P1Z Series Guided Version

P1Z Series Guided Version Rodless Pneumatic ylinder Magnetically oupled orrosion resistant Guide carriage and endcaps in anodized aluminium Load fixing by 4 tapped holes onto the guide carriage ylinder mounting End cap with mounting

More information

Contents R2 1. Inductive Proximity Sensors

Contents R2 1. Inductive Proximity Sensors Contents General Information Quick Selection Guide...................... page R2 2 Technical Definitions and Terminology........ page R2 5 Introduction............................... page R2 7 Applications..............................

More information

WG Series Double Guided Wedge Grippers

WG Series Double Guided Wedge Grippers WG Series Grippers www.numatics.com Table of Contents WG Series Parallel Gripper Features & Benefits 3 How To Order 4 WGS50 Dimensions 5 WGS50 Technical Specifications 5 WGL50 & WGS90 Dimensions 6 WGL50

More information

Climax Pneumatics. Cnomo NFE Cylinders Easley, South Carolina

Climax Pneumatics. Cnomo NFE Cylinders Easley, South Carolina Climax Pneumatics Cnomo NFE 49001 Cylinders 1-800-732-8704 Easley, South Carolina End Caps Tube Tie Rods Seals Piston Rod Diecast Aluminum Anodized Aluminum Zinc Coated or Stainless Steel Polyurethane

More information

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Fixed Displacement Bent Axis Axial Piston Motors TMB 700 HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC

More information

HIGHLY SENSITIVE, SAFE AND RELIABLE SENSOR TECHNOLOGY FOR PNEUMATIC CYLINDERS

HIGHLY SENSITIVE, SAFE AND RELIABLE SENSOR TECHNOLOGY FOR PNEUMATIC CYLINDERS HIGHLY SENSITIVE, SAFE AND RELIABLE SENSOR TECHNOLOGY FOR PNEUMATIC CYLINDERS 2 Sensor technology for pneumatic cylinders Expertise The choice is yours We offer a wide range of sensors for pneumatic cylinders

More information

Linear Guides Series OSP-E

Linear Guides Series OSP-E inear Guides Series OSP-E Contents Description Page Overview 115-116 Plain Bearing SIDEINE 117-118 Roller Guide POWERSIDE 119-122 Ball Bushing Guide GUIDEINE 123-126 Aluminium Roller Guide PROINE 127-129

More information

pneumatic swing clamps

pneumatic swing clamps pneumatic swing clamps Sizing and Application Chart Series Standard Features Bore Clamping Clamping Force [lbf.]n 90 Series [0.86] 22 [0.] 13 [34] 0 Arm rotates at the top of stroke Shielded rod protects

More information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi 46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils

More information

pneumatic grippers parallel jaws DirectConnect TM DPG Series

pneumatic grippers parallel jaws DirectConnect TM DPG Series pneumatic grippers parallel jaws DirectConnect TM Modular Series DPG Series Grippers Can be Mounted and Operated in Any Orientation Up to 5 million Cycles in Typical Life Cycle Temperature Operating Range

More information

-U- Type discontinued. -H- Note. Available up until Angle grippers HGW Key features. 2 Internet:

-U- Type discontinued. -H- Note. Available up until Angle grippers HGW Key features. 2 Internet: Key features At a glance Double-acting piston drive Self-centring Variable gripping action: External/internal gripping Versatility thanks to externally adaptable gripper fingers Wide range of options for

More information

Table of Contents Tiny Titan Series Features and Benefits How to Order Optional Features

Table of Contents Tiny Titan Series Features and Benefits How to Order Optional Features Table of Contents Tiny Titan Series. 3-22 Features and Benefits.................. 3 How to Order......................... 4 Optional Features..................... 5 Basic and Front Flange Mounts..........

More information

"COMPACT"MAGNETIC POSITION DETECTOR

COMPACTMAGNETIC POSITION DETECTOR Serie 881 "COMPACT"MAGNETC POSTON DETECTOR REED SWTCH TYPE for pneumatic cylinders : PES with tie rods, PES 453 or PEC with profiled barrel and dovetail grooves Detectors intended for use in potentially

More information

SERIES HH WITH HYDRAULIC ROD LOCK

SERIES HH WITH HYDRAULIC ROD LOCK HH LOCK TAB HH Rod Lock HH Options SERIES HH WITH HYDRAULIC LOCK The TRD difference... TRD s floating rod bushing design and RL Series Rod Lock = OPTIMIZED RESULTS and SUPERIOR PERFORMANCE. For rod locks

More information

Electronic pressure switch with integrated analogue output

Electronic pressure switch with integrated analogue output Electronic pressure switch with integrated analogue output RE 30276/03.1 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /1/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code

More information

CKR Compact Modules with Ball Rail Guides and Toothed Belt Drive. The Drive and Control Company

CKR Compact Modules with Ball Rail Guides and Toothed Belt Drive. The Drive and Control Company CKR Compact Modules with Ball Rail Guides and Toothed Belt Drive The Drive and Control Company Bosch Rexroth Corp. Linear Motion and Assembly Technologies CKR RE 8 615 (03.006) Rexroth Linear Motion Technology

More information

Parallel Grippers- DPW DIRECTCONNECT Wide Body Series

Parallel Grippers- DPW DIRECTCONNECT Wide Body Series DPW SERIES 1.196 Parallel Grippers- DPW DIRECTCONNECT Wide Body Series DIRECTCONNECT Connectivity: DIRECTCONNECT Tapped and Dowel mounting on body. Large or Wide Parts: Wide body design provides secure

More information

-H- Note. Feed separators HPV Key features at a glance. Separation of workpieces in the supply process

-H- Note. Feed separators HPV Key features at a glance. Separation of workpieces in the supply process Key features at a glance Separation of workpieces in the supply process Previously Required at least 2 drives, 2 valves and 4 proximity sensors Extensive programming required Today One unit (1 drive, 1

More information

CS1 COMPACT POWERED SLIDE

CS1 COMPACT POWERED SLIDE ISO 9001 REGISTERED CS1 COMPACT POWERED SLIDE WELKER 50mm BORE COMPACT CYLINDER NPT OR G PORTS OPTIONAL SOLID STATE CYLINDER SWITCH AVAILABLE METAL SHROUD KEEPS RAILS COVERED AT ALL TIMES (MOVES WITH )

More information

958A Compact Housing Linear Displacement Transducer

958A Compact Housing Linear Displacement Transducer 958A Compact Housing Linear Displacement Transducer THEINSIDER the most trusted information comes from INSIDE Simplify Installation and Serviceability The Need for Automation is Greater Today Than Ever

More information

2 pole 10 A PCB mount A1 A

2 pole 10 A PCB mount A1 A Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)

More information

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B Temposonics Absolute, Non-Contact Position Sensors M-Series Temposonics MH Measuring Length 50-2500 mm Document Number 551225 Revision B Compact Sensor for Mobile Hydraulics Linear, absolute Measurement

More information

FKHS Series. 3 Jaw Parallel Motion Pneumatic Grippers. Mounting Hole. Sensor Capable. Bottom tapped holes. Dowel Hole & Slot

FKHS Series. 3 Jaw Parallel Motion Pneumatic Grippers. Mounting Hole. Sensor Capable. Bottom tapped holes. Dowel Hole & Slot Catalog No. KHS- KHS Series Jaw Parallel Motion Pneumatic Grippers Mounting Hole Can be mounted from the gripper side Mounting slot for easy sensor installation Sensor Capable Bottom tapped holes Can be

More information

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current 0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket

More information

Steering column and sensor

Steering column and sensor Steering column and sensor Type LAB Series 1 x Nominal voltage 12 to 48 volt Output signal digital, analog and direction (option) HE 11874 / 09.2017 2 LAB HE 11874 / 09.2017 Page Content 4 4 5 6 7 7 8

More information

Ring Style Sensors 98 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) Fax (908)

Ring Style Sensors 98 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) Fax (908) Ring Style Sensors RING STYLE INDUCTiVE PROXIMITY SENSORS Altech Ring Sensors are used for variety of applications including punching and stamping operations to detect small metal parts and for the identification

More information

Bulletin 871P Can Sensors

Bulletin 871P Can Sensors Bulletin 871P Can Sensors Description Bulletin 871P inductive proximity can sensors are self-contained solid state devices, designed specifically for sensing size 202 to 704 metal cans without physical

More information

Electric Mini Slides MSC-EL

Electric Mini Slides MSC-EL Electric Mini Slides MSC-EL R10EN 2604 (11.08) The Drive & Control Company Electric Mini Slides, MSC-EL R10EN 2604 (11.08) Mini Slides, MSC-EL Product Description 4 Selection Guide 6 Maximum thrust 6

More information

PBS Series Power Block Slide

PBS Series Power Block Slide PBS Series Power Block Slide www.numatics.com Table of Contents PBS Series Features and Benefits 3 How To Order 4 Technical Specifications 4 Dimensions 5 Quick Disconnect Cables 6 Switch Information 6-7

More information

EQ Series OEM Aluminum NFPA Interchangeable Cylinder Line

EQ Series OEM Aluminum NFPA Interchangeable Cylinder Line Series OEM Aluminum NFPA Interchangeable Cylinder Line www.numatics.com Table of Contents EQ Series Features and Benefits 3 Standard Mounts 4 How to Order 5 Rod Ends 6 Dimensions 7 How to Order - EQ Series

More information

Brochure. Compact Cylinders. Setting a new standard for: Quality Reliability Value Global Compatibility

Brochure. Compact Cylinders. Setting a new standard for: Quality Reliability Value Global Compatibility Brochure Compact Cylinders Setting a new standard for: Quality Reliability Value Global Compatibility Actuators - Compact Cylinders How to Order MODEL MACQ - Compact Cylinder MAGNET Blank - No Magnet S

More information

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications Delivery address: Mackenrodtstraße 4 Phone: +49 66 600-0 Fax: +49 66 600-607 Phone: +44 79 655 Fax: +44 79 656 Data Sheet 400 Page /6 JUMO MIDAS C8 SW OEM pressure transmitter - seawater Applications Water

More information

Extruded Thrusters. Brochure

Extruded Thrusters. Brochure Extruded Thrusters Brochure Chrome plated stainless steel guide shafts optimize bearing performance Mounting flexibility: Through & C-bore Tapped bottom Tapped rear Bottom T-slots Bronze bushing for heavy

More information

S Series Stainless Steel NFPA Interchangeable Cylinder Line

S Series Stainless Steel NFPA Interchangeable Cylinder Line S Series Stainless Steel NFPA Interchangeable Cylinder Line w w w. n u m a t i c s. c o m Table of Contents S Series Features and Benefits 3 Standard Mounts 4 How to Order 5 Loading and Cushioning 6 Optional

More information

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it!

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it! UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS Sense it! Connect it! Bus it! Solve it! UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDE The position detection of piston on all standard