Parker Global Air Preparation System
|
|
- Antonia Reeves
- 6 years ago
- Views:
Transcription
1 Parker Global Air Preparation System Catalogue -UK March
2 -UK COMPLIANT DECLARATION OF COMPLIANCE (ROHS) European Directive //EU RoHS (Restriction us of certain Hazardous Substances in electrical and electronic equipment), restricts the use of the substances in the manufacture of specified electrical equipment. Lead: Product containing lead and its compound (except for applications of lead as an alloying element by weight in steel up to.%, in aluminium up to.% and in copper alloys up to % and in circuit board solder) must not exceed.% by weight Mercury: The concentration level must not exceed.% by volume Cadmium: The concentration level must not exceed.% by volume Hexavalent Chromiou: This is a corrosive protective finish used on our product line. Where this finish is utilized the Chromate solution is Hexavalent (Chrome ) free. Polybrominated Biphenyls (PBB): The concentration level must not exceed.% by weight. This substance is not know to be in any of our products. Polybrominated Diphenyl Esters (PBDE): The concentration level must not exceed.% by weight. This substance is not know to be in any of our products. Global Air Preparation products supplied by Parker Hannifin have been designed and manufactured in accordance with sound engineering practice, as defined by Article of Pressure Equipment Directive 9//EC. ATEX Following Ignition Hazard Assessments performed on the non-electrical Global Air Preparation products they are in accordance with the requirements of EN -:9, it was considered that the equipment does not contain its own source of ignition, and therefore is not within the scope of directive 9/9/EC. The products can be used in a Group II Category environment assuming that the ATEX Directive and the following conditions are complied with: Installation and maintenance of the product must be undertaken by qualified personnel. Do not mount the products in an area where impact may occur. Filters must be used to limit the introduction of particles and to capture particles generated in service. Supply air quality must be within ISO 8-: Class... Maximum working temperature to be as stated on product label. WARNING pulsating pressure and/or a closed circuit can generate heat. Deposits of dust on the product must not exceed mm thickness. Refer to technical file for surface areas of plastics. The unit must be earthed via the compressed air supply line. The unit must not come into contact with liquid solvents, acids or alkalis Refer to technical file for chemicals known to be incompatible. Product cleaning must be undertaken using a method complying with the specifications of the ATEX zone, preferably by using mild soap and water or antistatic products. Regulators, Filter Regulators: Do not use Regulators or Filter Regulators within systems that can create vibration within the Regulator / Filter Regulator unit. Solenoid Operated Valves: Are suitable for use in an ATEX environment, (Group II Category ) providing ATEX approved solenoids are fitted. Technical file available on request. Global Air Preparation product range is in compliance with REACH to ensure continued compliance additions to the list of SVHC (Substance of Very High Concern) are reviewed periodically. Global Air Preparation product range has been third party Shock & Vibration tested independently in accordance to EN : 999, Category Global Air Preparation product range has been designed and tested in accordance with ISO flow testing, envelope integrity, and catalog data presented. Filters ISO 8- & ISO 8-: 99 Regulators- ISO 9- & ISO 9-: Lubricators- ISO - & ISO -: 9 WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled Offer of Sale. Copyright,,. All Rights Reserved
3 -UK Introduction... - Atex Declaration... Shock & Vibration... Combinations P Mini Series... P Compact Series... P Standard Series...8 Dimensions...9 Filters P Mini Series... - P Compact Series... - P Standard Series... - Coalescing & Adsorber Filters P Mini Series... - P Compact Series P Standard Series... - Regulators P Mini Series... - P Mini Common Port Regulator Series... - P Compact Series... - P Compact Semi-Precision Regulator Series P Compact Common Port Regulator Series... - P Standard Series... - Filter / Regulators P Mini Series... - P Compact Series... - P Compact Semi-Precision Series P Standard Series... - Lubricators P Mini Series... - P Compact Series... - P Standard Series... - Proportional Regulators P Mini Series & P Compact Series Dump Valve Soft Start Valve... - Combined Soft Start / Dump Valve... - Solenoid Operators... - Combined Soft Start / Dump Valve Machine Directive - EN ISO Global Products Fitted with Pressure Sensor... Redundant Safety Exhaust Valve Ball Valve / Lockout Valve...8 Manifold Blocks...8 Pressure Sensors Kits & Accessories P Mini Series...8 P Compact Series...8 P Standard Series...88 Kits Pressure Switch PPS Safety Guide
4 -UK Introduction Parker Global Air Preparation System Global. Modular. Performance you need, wherever you need it. Full featured particulate and coalescing filters, regulators, filter/regulators, and lubricators are available with a wide range of standard options to meet air preparation needs. The comprehensive Global Air Preparation System is available in three body sizes with either BSPP or NPT to accommodate thread type requirements. Individual units can easily be assembled into various combinations, utilizing patented modular lightweight body connectors.
5 -UK Introduction Comprehensive Offering P Mini Series /" ports mm body width P Compact Series /", /8" and /" mm body width P Standard Series /" and /" mm body width Filters µ particulate,.µ and.µ coalescing, and adsorber available as standard Transparent or metal bowl with manual or auto float drains standard Regulators Available as stand alone, common port and electronic proportional Both relieving and nonrelieving versions available Filter / Regulators Compact design for space savings Available with all the same standard options as the filters and regulators Lubricators Combinations Accessories Proportional oil delivery over a wide range of air flows Fill under pressure Compact design for space savings Easily assembled Many configurations available Solenoid operated soft start, quick dump, and soft start/ quick dump valves Manifold blocks Ball style lockout / shutoff valve Repair kits, gauges, etc.
6 -UK Introduction Together we can power your application with clean, dry air Fast cycle times, high product quality, and low downtime all require a clean, dry pneumatic system to function properly. Parker has what it takes to make sure pneumatic systems perform at their best. Clean, dry pneumatic systems with Parker Global Air Preparation Key Stage As air is compressed to bar ( psig) and higher, the relative humidity quickly reaches % RH and air temperatures can reach between C and C ( F and 9 F). Particulate Oil For every C (F) that the air cools after leaving the heat of the compressor, % of the moisture condenses into liquid into the system. The excess moisture condenses and collects in the receiver tank and distribution lines. This condensate must be removed. Bulk liquid separators remove condensed liquids after the aftercooler, receiver, or anywhere within the distribution system. Bulk liquid separators also help protect downstream filters in the system where excess cooling takes place. Particulate filters are used for the removal of solid particle contaminants down to micron, as well as the removal of condensed liquids Note: Water and oil, in vapor form, pass through general purpose particulate filters. This type of filter should be used as a prefilter for the coalescing (oil removal) filter. Coalescing filters are designed to remove water and oil aerosols (not vapor) and particulate from air streams down to. micron in size. Installed in pairs, Particulate and Coalescing filters ensure a continuous supply of high quality air. Water Oil Vapor Water Vapor
7 -UK Introduction Stages Function Application Description Parker Global Air Preparation Solution Air Compressor All pneumatic systems Air leaving the compressor room at 9ºC (ºF) releases 9% of its moisture into the piping system when it cools to 8ºC (ºF) Customer supplied Bulk Liquid Removal Basic pneumatic systems Removes bulk liquid contamination and protects filters where excess cooling takes place in the distribution piping PTF Bulk Liquid Separator Particulate Filtration Basic pneumatic systems Removes solid particulates down to micron, and the separation of bulk contaminants. P, P, P Particulate Filter Coalescing Filtration Systems requiring highest quality air. Removes liquid aerosols and submicron particulates (not vapor) down to. micron. P, P, P Coalescing Filter Air Dryers Systems requiring air with reduced moisture content Removes water vapor from air stream. Dew point reduced down to -'C membrane and -'C desiccant. PXJ Membrane Dryer PTJ Regenerative Desiccant Dryer Hydrocarbon Removal Systems requiring highest quality air for critical applications Removal of odors and trace vapors for critical applications. P, P, P Activated Carbon (Adsorber) Filter Clean Dry Air Refrigeration, membrane and desiccant dryers lower the air s dew point by removing water vapor, providing appropriately dry air for the downstream application. Hydrocarbon and oil vapors are removed using filters utilizing activated carbon. These airborne hydrocarbons are often left over from the compressor oils.
8 -UK Introduction A completely modular air preparation system Easy to adjust nonrising knob with snap-lock, preventing accidental change of set pressure Ball Valve Filter / Regulator Pressure gauge Padlock slide Quick release bayonet-type integral bowl and bowl guard assembly Bowl guard with multiple viewing slots Manual drain with pipe-away, auto drain available 8
9 -UK Introduction Soft Start / Dump Valve -piece Patented modular body connector US Patent number,8,89 Coalescing Filter NPT or BSPP porting available Aluminum body 9
10 -UK Introduction Air Preparation P Mini Series mm body width /" Ported Flows up to: dm /s (SCFM) Filter () Coalescer. (.) Regulator (8) Filter/Regulator () Lubricator 9 () Features: Space saving integral gauge Manifold style regulators available OSHA compliant shut-off valves Soft-Start & Quick Dump valves Electronic Proportional Regulator P Compact Series mm body width /", /8", & /" Ported Flows up to: dm /s (SCFM) Filter 9 (8) Coalescer () Regulator 8 () Filter/Regulator () Lubricator (9) Features: Manifold style regulators available OSHA Compliant shut-off valves Soft-Start & Quick Dump valves Electronic Proportional Regulator P Standard Series mm body width /" & /" Ported Flows up to: dm /s (SCFM) Filter (8) Coalescer () Regulator () Filter/Regulator 8 () Lubricator () Features: OSHA Compliant shut-off valves Soft-Start & Quick Dump valves (Utilizes P size only) Electronic proportional regulator (Utilizes P size only)
11 -UK Introduction Valves and Actuators Mini Series Complimentary Products The P Mini Series FRL s and accessories are well matched for use with these Parker valves and actuators. Isys Micro Moduflex OSP-P PD Compact Series Complimentary Products PA The P Series FRL s & accessories are well matched for use with these Parker valves and actuators. Isys ISO Isys HA / HB PD OSP-P Standard Series Complimentary Products The P Series FRL s & accessories are well matched for use with these Parker valves and actuators. Isys ISO Isys HA / HB PD OSP-P
12 -UK Introduction Complete Pneumatic System Common Port Manifold Regulators Multiple output pressures (P, P, P, etc.) with common inlet (P) Available in two sizes P and P Balanced valve design for accurate pressure regulation Outlet pressure ports in front and rear of unit. Multiple spring ranges available P P P P P Electronic Proportional Regulator Electro-Pneumatic regulator Integrated systems control Accurate output pressure Micro parameter settings Selectable I/O parameters Quick, full flow exhaust LED display indicates output pressure No air consumption in steady state Multiple mounting options Protection to IP PP Mini Series PP Compact Series Semi Precision Regulator and Filter/Regulator Available in P compact series Fine adjustment sensitivity Good repeatability and minimal pressure drop Good flow capacity Light gray knob for easy identification Optional Tamperproof Kits One facilitates the permanent tamperproofing of the Regulator and Filter/Regulator units Hinged black part clamps over control knob and is locked in place after sliding yellow cover over it Other allows for removable lockout/tagout tamperproofing - Four pad lock location holes tagout - Hinged locking clamp secures over existing knob via yellow cover which is slid over into place Additional Options (Consult factory for availability) T-Handle (P only) Preset and Tamperproof Preset Pressure Limiter
13 -UK Introduction Application Guide FRL to Valve: The chart below contains recommendations for the correct selection of Global Air Preparation units to suit the number and size of valves in a typical application. P Mini Series P Compact Series P Standard Series Number of valves that would actuate at once 8 9 Moduflex Isys Micro HB / Viking Xtreme Moduflex HA / Global ISO See Larger Parker FRL Offering Actuator to FRL: The chart below contains recommendations for the correct selection of Global Air Preparation units suitable for each cylinder size. If you have a tube length over m, choose one tube size larger than the chart. The table is based on a Maximum cylinder speed of.m/s Cyl Ø mm Cyl Ø inches (/) (/) (9/) (/) () 8 (-/8) Cylinder bore size (-/) (-/) (-/) () (-/) () 8 (-/) () Tube Ø mm Tube Ø inches (/) (/) (/) (/) (/) Tube diameter external (/) (/) 8 (/) 8 (/) 8 (/) (/8) (/8) (/) (/) Number of cylinders actuating at once 8 9 P Mini Series P Compact Series P Standard Series See Larger Parker FRL Offering Note: Data listed above is simply a guideline for a typical application only. Proper sizing and correct flow requirements must be taken into account.
14 -UK ATEX We DECLARATION Parker Hannifin Manufacturing Austria GmbH Badener Straße Wiener Neustadt Austria Product Series Category Filter* PFB, PFB, PFA for zone, Regulator PRB, PRB, PRA for zone, Filter regulator* PEB, PEB, PEA for zone, Lubricator* PLB, PLB, PLA for zone, Ball Valve & Slide Valve PVB, PVB, PVB for zone, Manifold PMA, PMA, PMA for zone, For non-fitted solenoid product Soft start & Dump Valve PTA, PTA for zone, Soft Start Valve PSA, PSA for zone, Dump Valve PDA, PDA for zone, *Filter, Filter Regulator and Lubricator This evaluation applies to products fitted with metal bowls only. Following Ignition Hazard Assessments performed on the non-electrical products listed above, in accordance with the requirements of EN -:9, it was considered that the equipment does not contain its own source of ignition, and therefore is not within the scope of directive 9/9/EC. The products can be used in a Group II Category environment assuming that the ATEX Directive and the following conditions are complied with: Installation and maintenance of the product must be undertaken by qualified personnel. Do not mount the products in an area where impact may occur. Filters must be used to limit the introduction of particles and to capture particles generated in service. Supply air quality must be within ISO 8-: Class... Maximum working temperature to be as stated on product label. WARNING pulsating pressure and/or a closed circuit can generate heat. Deposits of dust on the product must not exceed mm thickness. Refer to technical file for surface areas of plastics. The unit must be earthed via the compressed air supply line. The unit must not come into contact with liquid solvents, acids or alkalis Refer to technical file for chemicals known to be incompatible. Product cleaning must be undertaken using a method complying with the specifications of the ATEX zone, preferably by using mild soap and water or antistatic products. Regulators, Filter Regulators: Do not use Regulators or Filter Regulators within systems that can create vibration within the Regulator/Filter Regulator unit. Solenoid Operated Valves: Are suitable for use in an ATEX environment, (Group II Category ) providing ATEX approved solenoids are fitted. Technical file available on request. Approved by: Engineering Manager Air Preparation EMEA
15 -UK Shock & Vibration Validated for transport applications Position of T-Brackets for multiple units As you would expect from a member of the Rail Industry Association, Global air preparation meets the test specification standards enabling the Global series to be used as a validated product in a variety of rail applications. Railway Industry Association CEI/ICE 999- Category (BS EN :999) Recommended mounting / fixation method for use in transportation applications. The use of a port block kit and T-bracket should be used at all times (angle / L-brackets should not be used in rail applications) Additional security is recomended with the use of vibration proof adhesive on the wall mounting screws to the port / connector block Inlet (P) and Outlet (P) ports should always have a T-Bracket fixation to eliminate product canterlever stress L brackets should not be used in the use for rail service For illustration purposes only
16 -UK P Series Popular Combinations: Inlet pressure bar ( psig), Secondary pressure. bar (9. psig), bar (. psig) pressure drop. Filter + Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Pulse drain Weight /" dm /s (scfm) PCBGEMNTLNW. kg (. lbs) PCBGEBNTLNW. kg (. lbs) Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Pulse drain Weight /" dm /s 8 (scfm) PCAGEMNTLNW. kg (. lbs) PCAGEBNTLNW.kg (. lbs) Ball Valve + Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Pulse drain Weight /" dm /s 8 (scfm) PQAGEMNTLNW. kg (. lbs) PQAGEBNTLNW.kg (. lbs) Ball Valve + Filter/Regulator Combinations + Poly bowl micron element, 8 bar Regulator + Gauge and Wall Mounting Brackets Port size Flow Manual drain Weight Pulse drain Weight /" dm /s 8 (scfm) PQNGEMNTW. kg (.88 lbs) PQNGEBNTW. kg (.88 lbs) P E N L N W Combination Combination Shut off + Combi C Q Combination type F/R+L A F+R+L B F/R N Thread type BSPP NPT 9 Port size / Bowl type Poly bowl with bowl guard Metal bowl without sight glass Note: All bowl types are the same for each component Example: If a G is specified for a F+L, both units would get a poly bowl with bowl guard. G M Drain type Manual drain Pulse drain M B Adjustment range With square gauge bar * V bar S 8 bar ** T Without gauge bar Y bar L 8 bar N bar H Add only for options with Lubricator * Unit comes with - bar, gauge respectively ** Unit comes with - bar, gauge respectively Option not available with F+R+L Bar gauges fitted to BSPP PSI gauges fitted to NPT
17 -UK P Series Popular Combinations: Inlet pressure bar ( psig), Secondary pressure. bar (9. psig), bar (. psig) pressure drop. Filter + Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s (scfm) PCBGEMNGLNW.9 kg (.8 lbs) PCBGEANGLNW.9 kg (.8 lbs) /8" dm /s 8 (scfm) PCBGEMNGLNW.9 kg (.8 lbs) PCBGEANGLNW.9 kg (.8 lbs) /" dm /s 8 (scfm) PCBGEMNGLNW.9 kg (.8 lbs) PCBGEANGLNW.9 kg (.8 lbs) Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s (scfm) PCAGEMNGLNW. kg (. lbs) PCAGEANGLNW. kg (. lbs) /8" dm /s (scfm) PCAGEMNGLNW. kg (. lbs) PCAGEANGLNW. kg (. lbs) /" dm /s 9 (scfm) PCAGEMNGLNW. kg (. lbs) PCAGEANGLNW. kg (. lbs) Ball Valve + Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /8" dm /s (scfm) PQAGEMNGLNW. kg (. lbs) PQAGEANGLNW. kg (. lbs) /" dm /s 9 (scfm) PQAGEMNGLNW. kg (. lbs) PQAGEANGLNW. kg (. lbs) Ball Valve + Filter/Regulator Combinations + Poly bowl micron element, 8 bar Regulator + Gauge and Wall Mounting Brackets Port size Flow Manual drain Weight Auto drain Weight /8" dm /s (scfm) PQNGEMNGW. kg (. lbs) PQNGEANGW. kg (. lbs) /" dm /s 9 (scfm) PQNGEMNGW. kg (. lbs) PQNGEANGW. kg (. lbs) P E N L N W Combination Combination C Shut off + Combination Q Option not available with F+R+L and /" port size () Combination type F/R+L A F+R+L B Thread type Port size BSPP / NPT 9 /8 / Bowl type Poly bowl with bowl guard Metal bowl with sight glass G S Drain type Auto drain Manual drain A M Adjustment range With round gauge - bar; - psi;. MPa Z bar; psi;. MPa M 8 bar; psi;.8 MPa G Without gauge bar Y bar L 8 bar N bar H Add only for options with Lubricator F/R N Note: All bowl types are the same for each component Example: If a G is specified for a F+L, both units would get a poly bowl with bowl guard.
18 -UK P Series Popular Combinations: Inlet pressure bar ( psig), Secondary pressure. bar (9. psig), bar (. psig) pressure drop. Filter + Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s 9 (scfm) PCBGEMNGLNW.8 kg (. lbs) PCBGEANGLNW.8 kg (. lbs) /" dm /s (scfm) PCBGEMNGLNW.8 kg (. lbs) PCBGEANGLNW.8 kg (. lbs) Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s (scfm) PCAGEMNGLNW. kg (. lbs) PCAGEANGLNW. kg (. lbs) /" dm /s (scfm) PCAGEMNGLNW. kg (. lbs) PCAGEANGLNW. kg (. lbs) Ball Valve + Filter/Regulator + Lubricator Combinations, Poly bowl micron element, 8 bar ( psig) regulator + gauge and wall mounting brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s (scfm) PQAGEMNGLNW. kg (. lbs) PQAGEANGLNW. kg (. lbs) /" dm /s (scfm) PQAGEMNGLNW. kg (. lbs) PQAGEANGLNW. kg (. lbs) Ball Valve + Filter/Regulator Combinations + Poly bowl micron element, 8 bar Regulator + Gauge and Wall Mounting Brackets Port size Flow Manual drain Weight Auto drain Weight /" dm /s (scfm) PQNGEMNGW. kg (. lbs) PQNGEANGW. kg (. lbs) /" dm /s (scfm) PQNGEMNGW. kg (. lbs) PQNGEANGW. kg (. lbs) P E N L N W Combination Combination C Shut off + Combination Q Option not available with F+R+L Thread type BSPP NPT 9 Port size / / Drain type Auto drain Manual drain A M Adjustment range With round gauge - bar; - psi;. MPa Z bar; psi;. MPa M 8 bar; psi;.8 MPa G Add only for options with Lubricator Combination type F/R+L A F+R+L B F/R N Bowl type Poly bowl with bowl guard Metal bowl with sight glass G S Note: All bowl types are the same for each component Example: If a G is specified for a F+L, both units would get a poly bowl with bowl guard. 8
19 -UK P, P, P Series Popular Combination Dimensions PC 8 (.) (.) 9 Round (.8) Gauge 8 Square (.9) Gauge 9. (.) (.) (.) (.) 9 Round (.8) Gauge 8 Square (.9) Gauge 9. (.) (.8) (.8) (.8).9 (.9) (.8) 9. (.9) mm (/") I.D. Tube Barb fitting. Bowl (.) Removal Clearance mm (/") I.D. Tube Barb fitting Bowl (.) removal clearance PC 9 (.8). (.). Round (.) Gauge 98. Square (.8) Gauge. (.8). (.) 98 (.8) 9 (.). Round (.) Gauge 98. Square (.8) Gauge. (.8) (.9) (.9). (.) (.9) (.9) 9. (9.) Bowl 8 removal (.8) clearance. (Manual and Auto Drain.) mm (/) I.D. tube barb fitting Bowl 8 removal (.8) clearance. (Manual and Auto Drain.) PC (.). (.) (.). (.8). (.) (9.) 8 (.) (.). (.8) (.9) (.9) (.9) (.9) 9 (.) 8 (9.).8 mm (.9) I.D. Tube Barb fitting Bowl removal clearance. (.) (Manual and Auto Drain.).8 mm (.9) I.D. Tube Barb fitting Bowl removal clearance. (.) (Manual and Auto Drain.) 9
20 -UK P Series Mini Particulate Filter - P Symbols Manual drain Pulse drain Integral /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction One hand operation for easy element cartridge removal Positive bayonet latch to ensure correct & safe fitting Options: PFB E N Basic series Global modular mini particulate filter PFB Thread type BSPP NPT 9 N Mounting No bracket Drain type Port size / M B Manual drain Pulse drain Bowl type Bold items are most common. Element µ Element E G M Poly bowl with bowl guard Metal bowl without sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - manual drain () ().8 (.9) (.8) (.8) PFBEGMN /" Poly bowl - pulse drain () () 9. (.) (.8) (.8) PFBEGBN /" Metal bowl - manual drain () ().8 (.9) (.8) (.8) PFBEMMN /" Metal bowl - pulse drain () () 9. (.) (.8) (.8) PFBEMBN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. (.9 psig) pressure drop.
21 -UK P Series Specifications Flow capacity* / dm /s ( scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration Useful retention micron cm (. US oz.) Port size BSPP / NPT / Weight. kg (. lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates) Within ISO 8-: Class (Particulates) Flow Charts / Filter Pressure Drop - (psig) Pressure Drop - bar..... Primary Pressure - bar Primary Pressure - psig Flow - dm /s Flow - (scfm) Material Specifications Body Body cap Bowl Bowl guard Element retainer Baffle Filter element Seals Aluminum ABS Polycarbonate Nylon Acetal Acetal Sintered polyethylene Nitrile Dimensions Repair and Service Kits (.8).8 (.9) (.8) (.9). (.8) 9. (.) Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / w/o sight gauge manual drain PKBBMM Plastic bowl / Bowl guard pulse drain PKBBGB Metal bowl / w/o sight gauge pulse drain PKBBMB µ particle filter element PKAESE C-bracket (fits to body) PKAMW T-bracket with body connector PKAMT Body connector PKACB Manual Drain mm (/) I.D. tube barb fitting Bowl removal (.) clearance Pulse Drain
22 -UK P Series Compact Particulate Filter - P Symbols Manual drain Auto drain Integral /", /8" or /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Options: PFB E N Basic series Global modular compact particulate filter PFB Thread type BSPP NPT 9 N Mounting No bracket Drain type Port size / /8 / G M Manual drain A Auto drain Bowl type Poly bowl with bowl guard Bold items are most common. Element µ Element E S Metal bowl with sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - manual drain () () 9. (.9) (.) (.) PFBEGMN /" Poly bowl - auto drain () () 8. (.) (.) (.) PFBEGAN /" Metal bowl - manual drain () () 9. (.9) (.) (.) PFBESMN /" Metal bowl - auto drain () () 8. (.) (.) (.) PFBESAN /8" Poly bowl - manual drain (8) () 9. (.9) (.) (.) PFBEGMN /8" Poly bowl - auto drain (8) () 8. (.) (.) (.) PFBEGAN /8" Metal bowl - manual drain (8) () 9. (.9) (.) (.) PFBESMN /8" Metal bowl - auto drain (8) () 8. (.) (.) (.) PFBESAN /" Poly bowl - manual drain 9 (8) () 9. (.9) (.) (.) PFBEGMN /" Poly bowl - auto drain 9 (8) () 8. (.) (.) (.) PFBEGAN /" Metal bowl - manual drain 9 (8) () 9. (.9) (.) (.) PFBESMN /" Metal bowl - auto drain 9 (8) () 8. (.) (.) (.) PFBESAN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. (.9 psig) pressure drop.
23 -UK P Series Specifications Flow capacity* / dm /s ( scfm) /8 dm /s (8 scfm) / 9 dm /s (8 scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration Useful retention micron cm (. US oz.) Port size BSPP / NPT /, /8, / Weight.8 kg (. lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates) Within ISO 8-: Class (Particulates) Material Specifications Body Aluminum Body cap ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Bowl guard Nylon Deflector Polypropylene Element retainer / Baffle Acetal Filter element Sintered polyethylene Seals Nitrile Sight gauge Metal bowl Nylon Dimensions (.) (.) (.8). (.) Flow Charts PFB /" Filter Pressure Drop - (psig) Pressure Drop - bar..... PFB /8" Filter Pressure Drop - (psig) PFB /" Filter Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar..... Primary Pressure - bar Primary Pressure - psig Flow - dm /s Flow - (scfm) Primary Pressure - bar Primary Pressure - psig..... Primary Pressure - bar Primary Pressure - psig Flow - dm /s 8 Flow - (scfm) 8 Flow - dm /s 8 Flow - (scfm) 9. (.9) 8. (.) Repair and Service Kits mm (/) I.D. tube barb fitting Manual Drain Bowl 8 removal (.8) clearance Automatic Drain Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / Sight gauge manual drain PKBBSM Auto drain PKADA µ particle filter element PKAESE L-bracket (fits to body) PKAML T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB
24 -UK P Series Standard Particulate Filter - P Symbols Manual drain Auto drain Integral /" or /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Options: PFA E N Basic series Global modular standard particulate filter PFA Thread type BSPP NPT 9 N Mounting No bracket Drain type Port size / / M A Manual drain Auto drain Bowl type Bold items are most common. Element µ Element E G S Poly bowl with bowl guard Metal bowl with sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - manual drain (8) () (8.9) (.8) (.8) PFAEGMN /" Poly bowl - auto drain (8) () (8.) (.8) (.8) PFAEGAN /" Metal bowl - manual drain (8) () (8.9) (.8) (.8) PFAESMN /" Metal bowl - auto drain (8) () (8.) (.8) (.8) PFAESAN /" Poly bowl - manual drain 8 () () (8.9) (.8) (.8) PFAEGMN /" Poly bowl - auto drain 8 () () (8.) (.8) (.8) PFAEGAN /" Metal bowl - manual drain 8 () () (8.9) (.8) (.8) PFAESMN /" Metal bowl - auto drain 8 () () (8.) (.8) (.8) PFAESAN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. (.9 psig) pressure drop.
25 -UK P Series Specifications Flow capacity* / dm /s (8 scfm) / 8 dm /s ( scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration Useful retention micron 8 cm (.8 US oz.) Port size BSPP / NPT /, / Weight. kg (. lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates) Within ISO 8-: Class (Particulates) Material Specifications Body Aluminum Body cap ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Bowl guard Nylon Deflector Polypropylene Element retainer / Baffle Acetal Filter element Sintered polyethylene Seals Nitrile Sight gauge Metal bowl Polycarbonate Flow Charts / Filter Pressure Drop - (psig) Pressure Drop - (psig) Pressure Drop - bar / Filter..... Pressure Drop - bar Primary Pressure - bar Primary Pressure - psig Flow - dm /s 8 Flow - (scfm) Primary Pressure - bar Primary Pressure - psig Flow - dm /s 8 Flow - (scfm) Dimensions Repair and Service Kits (.8) (8.9) (.8) (.) (.) (8.) Plastic bowl / Bowl guard manual drain PKABGM Metal bowl / Sight gauge manual drain PKABSM Auto drain PKADA µ particle filter element PKAESE L-bracket (fits to body) PKAML T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB mm (/) I.D. tube barb fitting Manual Drain Bowl removal (.) clearance (Manual & Auto Drain) Use mm or /8" Flex Tubing Automatic Drain
26 -UK P Series Mini Coalescing and Adsorber Filters - P Symbol Integral /" ports (NPT & BSPP) Removes liquid aerosols and sub micron particles Oil free air for critical applications, such as air gauging, pneumatic instrumentation and control Differential Pressure Indicator (DPI) standard on Coalescing Filters Positive bayonet latch to ensure correct and safe fitting Adsorbing activated carbon element removes oil vapors and most hydrocarbons Note: To optimize the life of coalescing element, it is advisable to install a PF pre-filter with a micron element upstream of the coalescing filter. To optimize the life of an Adsorber it is advisable to install a P Coalescing Filter upstream of the Adsorber. Adsorber element should be replaced approximately every hours of service. Options: PFB N Basic series Global modular mini coalescing filter PFB Thread type BSPP NPT 9 N Mounting No bracket Drain type Port size / B M Pulse drain) Manual drain Bowl type Bold items are most common. Element.µ Element C.µ Element with DPI D µ Element 9 µ Element with DPI Q Adsorber A G M Poly bowl with bowl guard Metal bowl without sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl -. micron - manual drain. (.) ().9 (.9) (.8) (.8) PFBDGMN /' Poly bowl -. micron - pulse drain. (.) (). (.9) (.8) (.8) PFBDGBN /" Metal bowl -. micron - manual drain. (.) ().9 (.9) (.8) (.8) PFBDMMN /' Metal bowl -. micron - pulse drain. (.) (). (.9) (.8) (.8) PFBDMBN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. ( psig) pressure drop.
27 -UK P Series Specifications Flow capacity. micron coalescing. dm /s ( scfm). micron coalescing. dm /s (. scfm) Activated carbon adsorber dm /s (. scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration. and. micron Adsorber Max. oil carryover (ppm O C ( O F) Useful retention cm (. US oz.) Port size BSPP / NPT / Weight. kg (. lbs) Inlet pressure. bar (9. psig), Pressure drop. bar ( psig), Saturated Element. Useful retention refers to volume below the quiet zone baffle. Without pressure indicator (DPI) max. pressure for metal bowl version is bar ( psig). Material Specifications Body Aluminum Body cap ABS Bowl Plastic bowl Polycarbonate Metal bowl Aluminum Filter element. and. micron Borosilicate cloth Adsorber Activated carbon Seals Nitrile Flow Charts P -. micron flow Pressure Drop - (psig) P -. micron flow Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar Primary Pressure - bar Primary Pressure - psig Primary Pressure - bar Primary Pressure - psig Flow - dm /s Flow - (scfm). 8 Saturated Element Flow 8 Flow - dm /s Flow - (scfm). 9. Saturated Element Flow. 9. Dimensions Repair and Service Kits (.8). (.8).8 (.9) (.8) (.9). (.8). (.8) 9. (.) Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / w/o sight gauge manual drain PKBBMM Plastic bowl / Bowl guard pulse drain PKBBGB Metal bowl / w/o sight gauge pulse drain PKBBMB µ coalescing filter element PKAES9.µ coalescing filter element PKAESC Activated carbon adsorber filter element PKAESA C-bracket (fits to body) PKAMW T-bracket with body connector PKAMT Body connector PKACB Differential pressure indicator (replacement) PKBRQ Manual Drain mm (/) I.D. tube barb fitting Bowl removal (.) clearance Pulse Drain
28 -UK P Series Compact Coalescing and Adsorber Filter - P Symbol Integral /", /8" or /" ports (NPT & BSPP) Removes liquid aerosols and sub micron particles Oil free air for critical applications, such as air gauging, pneumatic instrumentation and control Differential Pressure Indicator (DPI) standard on Coalescing Filters Positive bayonet latch to ensure correct & safe fitting Adsorbing activated carbon element removes oil vapors and most hydrocarbons Options: Note: To optimize the life of coalescing element, it is advisable to install a PF pre-filter with a micron element upstream of the coalescing filter. To optimize the life of an Adsorber it is advisable to install a P Coalescing Filter upstream of the Adsorber. Adsorber element should be replaced approximately every hours of service. PFB N Basic series Global modular compact coalescing filter PFB Thread type BSPP NPT 9 Mounting N No bracket Drain type Manual drain Auto drain Port size / /8 / G S M A Bowl type Poly bowl with bowl guard Metal bowl with sight gauge Bold items are most common. Element.µ Element C.µ Element with DPI D µ Element 9 µ Element with DPI Q Adsorber A Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl -. micron, manual drain () (). (8.) (.) (.) PFBDGMN /" Poly bowl -. micron, auto drain () (). (8.) (.) (.) PFBDGAN /" Metal bowl -. micron, manual drain () (). (8.) (.) (.) PFBDSMN /" Metal bowl -. micron, auto drain () (). (8.) (.) (.) PFBDSAN /8" Poly bowl -. micron, manual drain () (). (8.) (.) (.) PFBDGMN /8" Poly bowl -. micron, auto drain () (). (8.) (.) (.) PFBDGAN /8" Metal bowl -. micron, manual drain () (). (8.) (.) (.) PFBDSMN /8' Metal bowl -. micron, auto drain () (). (8.) (.) (.) PFBDSAN /" Poly bowl -. micron, manual drain () (). (8.) (.) (.) PFBDGMN /" Poly bowl -. micron, auto drain () (). (8.) (.) (.) PFBDGAN /" Metal bowl -. micron, manual drain () (). (8.) (.) (.) PFBDSMN /" Metal bowl -. micron, auto drain () (). (8.) (.) (.) PFBDSAN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. ( psig) pressure drop. 8
29 -UK P Series Specifications Flow capacity. micron coalescing dm /s ( scfm). micron coalescing dm /s ( scfm) Activated carbon adsorber dm /s (8 scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration. and. micron Adsorber Max. oil carryover (ppm O C ( O F) Useful retention cm (. US oz.) Port size BSPP / NPT /, /8, / Weight Inlet pressure. bar (9. psig), Pressure drop. bar ( psig), Saturated Element. Useful retention refers to volume below the quiet zone baffle.. kg (. lbs) Flow Charts P -. micron flow Pressure Drop - (psig) P -. micron flow Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar Primary Pressure - bar Primary Pressure - psig.. Primary Pressure - bar Primary Pressure - psig Saturated Element Flow Flow - dm /s 8 Flow - (scfm) Saturated Element Flow Flow - dm /s 8 Flow - (scfm) Dimensions Material Specifications (.) (.) (.8) 8. (.9) Body Body cap Aluminum ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Filter element. and. micron Borosilicate cloth Adsorber Seals Activated carbon Nitrile Sight gauge Metal bowl Polycarbonate mm (/) I.D. tube barb fitting Manual Drain. (8.) Bowl 8 removal (.8) clearance. (8.) Automatic Drain Repair and Service Kits Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / Sight gauge manual drain PKBBSM Auto drain PKADA µ coalescing filter element PKAES9.µ coalescing filter element PKAESC Activated carbon adsorber filter element PKAESA L-bracket (fits to body) PKAML T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB Differential pressure indicator (replacement) PKARQ 9
30 -UK P Series Standard Coalescing and Adsorber Filter - P Symbol Integral /" or /" ports (NPT & BSPP) Removes liquid aerosols and sub micron particles Oil free air for critical applications, such as air gauging, pneumatic instrumentation and control Differential Pressure Indicator (DPI) standard on Coalescing Filters Positive bayonet latch to ensure correct & safe fitting Adsorbing activated carbon element removes oil vapors and most hydrocarbons Note: To optimize the life of coalescing element, it is advisable to install a PF pre-filter with a micron element upstream of the coalescing filter. To optimize the life of an Adsorber it is advisable to install a P Coalescing Filter upstream of the Adsorber. Adsorber element should be replaced approximately every hours of service. Options: PFA N Basic series Global modular standard coalescing filter PFA Thread type BSPP NPT 9 N Mounting No bracket Drain type Port size / / M A Manual drain Auto drain Bowl type Bold items are most common. Element.µ Element C.µ Element with DPI D µ Element 9 µ Element with DPI Q Adsorber A G S Poly bowl with bowl guard Metal bowl with sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl -. micron, manual drain (8) () (9.) (.8) (.8) PFADGMN /" Poly bowl -. micron, auto drain (8) () 9 (9.) (.8) (.8) PFADGAN /" Metal bowl -. micron, manual drain (8) () (9.) (.8) (.8) PFADSMN /" Metal bowl -. micron, auto drain (8) () 9 (9.) (.8) (.8) PFADSAN /" Poly bowl -. micron, manual drain (8) () (9.) (.8) (.8) PFADGMN /" Poly bowl -. micron, auto drain (8) () 9 (9.) (.8) (.8) PFADGAN /" Metal bowl -. micron, manual drain (8) () (9.) (.8) (.8) PFADSMN /" Metal bowl -. micron, auto drain (8) () 9 (9.) (.8) (.8) PFADSAN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. ( psig) pressure drop.
31 -UK P Series Specifications Flow capacity. micron coalescing dm /s (8 scfm). micron coalescing dm /s ( scfm) Activated carbon adsorber dm /s ( scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration. and. micron Adsorber Max. oil carryover (ppm O C ( O F) Useful retention 8 cm (.8 US oz.) Port size BSPP / NPT /, / Weight. kg (. lbs) Inlet pressure. bar (9. psig), Pressure drop. bar ( psig), Saturated Element. Useful retention refers to volume below the quiet zone baffle. Flow Charts P -. micron flow Pressure Drop - (psig) Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar..... Primary Pressure - bar Primary Pressure - psig P -. micron flow Saturated Element Flow. 9. Flow - dm /s 8 Flow - (scfm) Primary Pressure - bar Primary Pressure - psig Saturated Element Flow Flow - dm /s 8 Flow - (scfm) Dimensions Material Specifications (.8) DPI (.8) (.) (.) Body Body cap Aluminum ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Filter element. and. micron Borosilicate cloth Adsorber Seals Activated carbon Nitrile Sight gauge Metal bowl Polycarbonate mm (/) I.D. tube barb fitting Manual Drain (9.) Bowl removal clearance (.) (Manual & Auto Drain) Use mm or /8" Flex Tubing 9 (9.) Automatic Drain Repair and Service Kits Plastic bowl / Bowl guard manual drain PKABGM Metal bowl / Sight gauge manual drain PKABSM Auto drain PKADA µ coalescing filter element PKAES9.µ coalescing filter element PKAESC Activated carbon adsorber filter element PKAESA L-bracket (fits to body) PKAML T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB Differential pressure indicator (replacement) PKARQ
32 -UK P Series Mini Regulator - P Symbols Self relieving regulator with gauge Non relieving regulator Integral /" ports (NPT & BSPP) Robust but lightweight aluminum construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation. Relieving & Non-relieving types Non-rising knob Options: PRB N P Basic series Global modular mini regulator Bold items are most common. PRB Thread type BSPP NPT 9 Port size / Relief Relieving Non-relieving Reverse flow / Relieving B N R P Mounting Plastic panel mount nut Adjustment range With square gauge With round gauge psig bar Z bar; psig;. MPa = * V = * M bar; psig;. MPa = S = G 8 bar; psig;.8 MPa = T = 8 J bar; psig;. MPa Without gauge Y bar; psig;. MPa * Unit comes with - bar or - psig gauge respectively. L bar; psig;. MPa Bar gauges fitted to BSPP N 8 bar; psig;.8 MPa PSI gauges fitted to NPT H bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving (8) (). (.) (.8) (.8) PRBBNNP /" 8 bar ( psig) + gauge (8) (). (.) (.8). (.) PRBBNTP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
33 -UK P Series Specifications Flow capacity* / dm /s (8 scfm) Operating temperature - C to. C (- F to F) Max. supply pressure bar ( psig) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT / Gauge port ( ea.)** BSPP / NPT /8 Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). ** Non-gauge option only. Units with square gauges: - C to. C ( F to F) Flow Charts / Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar. bar 8 psig. psig Flow - dm /s 8 Flow - (scfm) Secondary Pressure - bar Material Specifications Repair and Service Kits Body Adjustment knob Bonnet Diaphragm assembly Valve assembly Springs Seals Panel nut Aluminum Acetal PBT Brass / Nitrile Brass / Nitrile Steel Nitrile Acetal Panel mount nut - aluminum Panel mount nut - plastic Angle bracket (attaches via panel nut) C-bracket (fits to body) T-bracket with body connector Body connector PKAMM PKAMP PKBMR PKAMW PKAMT PKACB Dimensions Gauges NOTE: mm (. in.) hole required for panel nut mounting. (.8).8 (.). (.). Round (.) Gauge. Square (.) Gauge (.8) (.9). (.) Square flush mount gauge - bar KSCRB - bar KSCRB - psig KSCR - psig KSCR Square with adapter kit - bar PG-PR - bar PG-PR - psig PG-PR9 - psig PG-PR9 mm Round /8" center back mount! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. - psig / - bar PD-KABAYN - psig / - bar PD-KABALN - psig / - bar PD-KABANN - psig / - bar PD-KABAHN For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
34 -UK P Series Mini Common - P Regulator - P Symbols P P P P P P Self relieving regulator with gauge Non relieving regulator P P P P P Manifold style regulator with line pressure on both sides Pressure output is at front or rear Inlet port /" (NPT & BSPP) Working port /8" Robust construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Relieving & Non-relieving types Non-rising knob Options: PHB N P Basic series Global modular mini common regulator PHB Thread type BSPP NPT 9 Port size / Working port /8". Relief Relieving Non-relieving Reverse flow / Relieving B N R P Mounting Plastic panel mount nut Adjustment range With square gauge Without gauge psig bar Y bar; psig;. MPa = * V = * L bar; psig;. MPa = S = N 8 bar; psig;.8 MPa = T = 8 H bar; psig;. MPa * Unit comes with - bar or - psig gauge respectively. Bar gauges fitted to BSPP PSI gauges fitted to NPT Bold items are most common. Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving () (). (.) (.8) (.8) PHBBNNP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
35 -UK P Series Specifications Flow capacity* / dm /s ( scfm) Operating temperature Max. supply pressure Adjusting range pressure - C to. C (- F to F) bar ( psig) - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) P Port size (Inlet / Outlet) BSPP / NPT / P Regulated ports ( ea.) BSPP / NPT /8 Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Flow Charts / Common Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar. bar. psig 8 psig Flow - dm /s Flow - (scfm) Secondary Pressure - bar Materials of Construction Body Adjustment knob Bonnet Diaphragm assembly Valve assembly Aluminum Acetal % Glass-filled PBT Brass / Nitrile Brass / Nitrile Dimensions Repair and Service Kits NOTE: mm (. in.) hole required for panel nut mounting. (.8).8 (.). (.) (.8) (.9). (.) Panel mount nut - aluminum PKAMM Panel mount nut - plastic PKAMP Angle bracket (attaches via panel nut) PKBMR T-bracket with body connector PKAMT Body connector PKACB Gauges Square with adapter kit - bar PG-PR - bar PG-PR - psig PG-PR9 - psig PG-PR9 WARNING! Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. mm Round /8" center back mount - psig / - bar PD-KABAYN - psig / - bar PD-KABALN - psig / - bar PD-KABANN - psig / - bar PD-KABAHN For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
36 -UK P Series Compact Regulator P Symbols Self relieving regulator with gauge Non relieving regulator Options: Integral /", /8" or /" ports (NPT & BSPP) Robust but lightweight aluminum construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Relieving & Non-relieving types Non-rising knob PRB N P Basic series Global modular compact regulator Bold items are most common. PRB Thread type BSPP NPT 9 Port size / /8 / Relief Relieving B Non-relieving N Note: Regulators will reverse flow as standard. With square gauge psig bar = * V = * = S = = T = 8 P Mounting Plastic panel mount nut Z M G J Y L N H Adjustment range With round gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Without gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving (8) () (.) (.) (.) PRBBNNP /" 8 bar ( psig) relieving + gauge (8) () (.) (.) 9 (.) PRBBNGP /8" 8 bar ( psig) relieving 8 () () (.) (.) (.) PRBBNNP /8" 8 bar ( psig) relieving + gauge 8 () () (.) (.) 9 (.) PRBBNGP /" 8 bar ( psig) relieving 8 () () (.) (.) (.) PRBBNNP /" 8 bar ( psig) relieving + gauge 8 () () (.) (.) 9 (.) PRBBNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating.
37 -UK P Series Specifications Flow capacity* / dm /s (8 scfm) /8 8 dm /s ( scfm) / 8 dm /s ( scfm) Operating temperature - C to. C (- F to F) Max. supply pressure Adjusting range pressure bar ( psig) - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, /8, / Gauge port ( ea.) BSPP / NPT / Weight. kg (.9 lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Material Specifications Body Adjustment knob Bonnet Diaphragm assembly Valve assembly Aluminum Acetal % Glass-filled nylon Nitrile / Zinc Brass / Nitrile Springs Main regulating valve Steel S.S. Seals Panel nut Dimensions NOTE: 8 mm (.9 in.) hole required for panel nut mounting. (.).8 (.9) 9 Round (.) Gauge (.8) (.) Nitrile Acetal 8. (.) Flow Charts / Regulator Secondary Pressure - (psig) /8 Regulator Secondary Pressure - (psig) / Regulator Secondary Pressure - (psig) Gauges Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Secondary Pressure - bar Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Secondary Pressure - bar Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Secondary Pressure - bar Repair and Service Kits Panel mount nut - aluminum Panel mount nut - plastic Angle bracket (attaches via panel nut) T-bracket with body connector T-bracket Body connector. (.) PKAMM PKAMP PKBMR PKAMT PKAMB PKACB mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB Square flush mount gauge - bar KSCRB - bar KSCRB - psig KSCR - psig KSCR Square with adapter kit - bar PG-PR - bar PG-PR - psig PG-PR9 - psig PG-PR9 For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
38 -UK P Series Compact Semi-Precision Regulator P Symbols Self relieving regulator with gauge Non relieving regulator Options: Integral /", /8" or /" ports (NPT & BSPP) Robust but lightweight aluminum construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Relieving & Non-relieving types Non-rising knob PRB N P Basic series Global modular compact regulator Bold items are most common. PRB Thread type BSPP NPT 9 Port size / /8 / Relief Relieving P Non-relieving E Note: Regulators will reverse flow as standard. Z M G J Y L N H P Mounting Plastic panel mount nut Adjustment range With round gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Without gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving () () (.) (.) (.) PRBPNNP /" 8 bar ( psig) relieving + gauge () () (.) (.) 9 (.) PRBPNGP /8" 8 bar ( psig) relieving () () (.) (.) (.) PRBPNNP /8" 8 bar ( psig) relieving + gauge () () (.) (.) 9 (.) PRBPNGP /" 8 bar ( psig) relieving () () (.) (.) (.) PRBPNNP /" 8 bar ( psig) relieving + gauge () () (.) (.) 9 (.) PRBPNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. 8
39 -UK P Series Specifications Flow capacity* / dm /s ( scfm) /8 dm /s ( scfm) / dm /s ( scfm) Effect of supply pressure variation. bar (. PSIG) for. bar ( PSIG) change in P Operating temperature Max. supply pressure Adjusting range pressure - C to. C (- F to F) bar ( psig) - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, /8, / Gauge port ( ea.) BSPP / NPT / Weight. kg (.9 lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Material Specifications Body Adjustment knob Bonnet Diaphragm assembly Valve assembly Aluminum Acetal % Glass-filled nylon Nitrile / Zinc Brass / Nitrile Springs Main regulating valve Steel S.S. Seals Panel nut Dimensions NOTE: 8 mm (.9 in.) hole required for panel nut mounting. (.) 9 Round (.) Gauge (.8) (.) Nitrile Acetal Flow Charts / Regulator Pressure Drop - (psig) 8 Pressure Drop - bar /8 Regulator Pressure Drop - (psig) / Regulator Pressure Drop - (psig) 8 8 Pressure Drop - bar Pressure Drop - bar Inlet Pressure - bar ( psig) 8. bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s Flow - (scfm) Inlet Pressure - bar ( psig) 8. bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s Flow - (scfm) Inlet Pressure - bar ( psig) 8. bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s Flow - (scfm).8 (.9). (.) Repair and Service Kits Panel mount nut - aluminum Panel mount nut - plastic Angle bracket (attaches via panel nut) T-bracket with body connector T-bracket Body connector 8. (.) PKAMM PKAMP PKBMR PKAMT PKAMB PKACB Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. 9
40 -UK P Series Compact Common - P Regulator - P Symbols P P Self relieving regulator with gauge Non relieving regulator Manifold style regulator with line pressure on both sides. P P P P P P Pressure output is at front or rear. Inlet ports /", /8" or /" (NPT & BSPP) Working port /" Robust construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Relieving & Non-relieving types Non-rising knob Options: PHB N P Basic series Global modular compact regulator Bold items are most common. PHB Thread type BSPP NPT 9 Port size / /8 / Working port /". Relief Relieving B Non-relieving N Note: Regulators will reverse flow as standard. P Mounting Plastic panel mount nut Adjustment range With square gauge With round gauge psig bar Z bar; psig;. MPa = * V = * M bar; psig;. MPa = S = G 8 bar; psig;.8 MPa = T = 8 J bar; psig;. MPa Without gauge Y bar; psig;. MPa * Unit comes with - bar or - psig L bar; psig;. MPa gauge respectively. N 8 bar; psig;.8 MPa H bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving () () (.) (.) (.) PHBBNNP /8" 8 bar ( psig) relieving () () (.) (.) (.) PHBBNNP /" 8 bar ( psig) relieving () () (.) (.) (.) PHBBNNP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
41 -UK P Series Specifications Flow capacity* / dm /s ( scfm) /8 dm /s ( scfm) / dm /s ( scfm) Operating temperature - C to. C (- F to F) Max. supply pressure bar ( psig) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, /8, / Gauge port ( ea.) BSPP / NPT / Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Flow Charts P Common Port Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Secondary Pressure - bar Material Specifications Body Aluminum Adjustment knob Acetal Bonnet % Glass-filled nylon Diaphragm assembly Nitrile / Zinc Valve assembly Brass / Nitrile Springs Main regulating valve Steel S.S. Seals Nitrile Panel nut Acetal Dimensions Repair and Service Kits Panel mount nut - aluminum Panel mount nut - plastic Angle bracket (attaches via panel nut) T-bracket with body connector T-bracket Body connector PKAMM PKAMP PKBMR PKAMT PKAMB PKACB NOTE: 8 mm (.9 in.) hole required for panel nut mounting. (.) (.) (.8).8 (.9)!. (.) WARNING 8. (.) Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB Square flush mount gauge - bar KSCRB - bar KSCRB - psig KSCR - psig KSCR Square with adapter kit - bar PG-PR - bar PG-PR - psig PG-PR9 - psig PG-PR9 For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
42 -UK P Series Standard Regulator - P Symbols Self relieving regulator with gauge Non relieving regulator Integral /" or /" ports (NPT & BSPP) Robust but lightweight aluminum construction Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Relieving & Non-relieving types Non-rising knob Options: PRA N P Basic series Global modular standard regulator Bold items are most common. PRA Thread type BSPP NPT 9 Port size / / Relief Relieving Non-relieving Reverse flow-relieving B N R Z M G J Y L N H P Mounting Plastic panel mount nut Adjustment range With round gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Without gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Part number /" 8 bar ( psig) relieving () () 9 (.8) (.8) PRABNNP /" 8 bar ( psig) relieving + gauge () () 9 (.8) 8 (.) PRABNGP /" 8 bar ( psig) relieving () () 9 (.8) (.8) PRABNNP /" 8 bar ( psig) relieving + gauge () () 9 (.8) 8 (.) PRABNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
43 -UK P Series Specifications Flow capacity* / dm /s ( scfm) / dm /s ( scfm) Operating temperature - C to. C (- F to F) Max. supply pressure bar ( psig) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, / Gauge port ( ea.) BSPP / NPT / Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Material Specifications Body Aluminum Adjustment knob Acetal Body cap ABS Bonnet % Glass-filled nylon Diaphragm assembly Nitrile / Zinc Bonnet % Glass-filled nylon Valve assembly Brass / Nitrile Springs Main regulating valve Steel S.S. Seals Nitrile Panel nut Acetal Flow Charts / Regulator Secondary Pressure - (psig) Secondary Pressure - (psig) 8 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar Secondary Pressure - bar 9 8 / Regulator. bar. psig 8. bar psig. bar 9. psig. bar 8 psig 8 Flow - dm /s 8 8 Flow - (scfm) Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar. bar 8 psig. psig 8 Flow - dm /s 8 8 Flow - (scfm) Dimensions Repair and Service Kits NOTE: mm (. in.) hole required for panel nut mounting. (.8) 8.8 (.) 8 Round.) Gauge (.8) (.) (.) Panel mount nut - aluminum Panel mount nut - plastic Angle bracket (attaches via panel nut) T-bracket with body connector T-bracket Body connector PKAMM PKAMP PKAMR PKAMT PKAMB PKACB 9 (.8)! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. CAUTION: REGULATOR PRESSURE ADJUSTMENT The working range of knob adjustment is designed to permit outlet pressures within their full range. Pressure adjustment beyond this range is also possible because the knob is not a limiting device. This is a common characteristic of most industrial regulators, and limiting devices may be obtained only by special design. For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
44 -UK P Series Mini Filter / Regulator - P Symbols Integral /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Options: PEB E N P Basic series Global modular mini filter / regulator PEB Thread type BSPP NPT 9 Element µ Element E B N Relief Relieving Non-relieving P Mounting Plastic panel mount nut Port size / B M Drain type Pulse drain Manual drain Bold items are most common. Bowl type Poly bowl with bowl guard Metal bowl without sight gauge G M Adjustment range With square gauge With round gauge psig bar Z bar; psig;. MPa = * V = * M bar; psig;. MPa = S = G 8 bar; psig;.8 MPa = T = 8 J bar; psig;. MPa * Unit comes with - bar or - psig Without gauge gauge respectively. Y bar; psig;. MPa Not available with poly bowl with bowl guard. L bar; psig;. MPa Bar gauges fitted to BSPP N 8 bar; psig;.8 MPa PSI gauges fitted to NPT bar; psig;. MPa H Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving - poly bowl - manual drain () ().9 (.9) (.8). (.) PEBEGMBNTP /" 8 bar ( psig) relieving - poly bowl - pulse drain () (). (.) (.8). (.) PEBEGBBNTP /" 8 bar ( psig) relieving - metal bowl - manual drain () ().9 (.9) (.8). (.) PEBEMMBNTP /" 8 bar ( psig) relieving - metal bowl - pulse drain () (). (.) (.8). (.) PEBEMBBNTP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
45 -UK P Series Specifications Flow capacity* / dm /s ( scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration micron Useful retention cm (. US oz.) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT / Gauge port ( ea.)** BSPP / NPT /8 Weight.9 kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). ** Non-gauge option only. Units with square gauges: - C to. C ( F to F) Air quality: Within ISO 8-: 99 Class (Particulates) Within ISO 8-: Class (Particulates)! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. Flow Charts / Filter / Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar bar psig. bar. psig. bar 9. psig. bar 8 psig Flow - dm /s Flow - (scfm) Material Specifications Body Aluminum Adjustment knob Acetal Body cap ABS Bonnet PBT Bowl Plastic bowl Polycarbonate Metal bowl Aluminum Bowl guard Nylon Filter element Polyethylene Seals Nitrile Springs Steel Valve assembly Brass / Nitrile Diaphragm assembly Brass / Nitrile Panel nut Acetal For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. Dimensions Repair and Service Kits (.8). Round (.9) Gauge (.8) (.9). (.89) Plastic bowl / Bowl guard manual drain PKBBGM Plastic bowl / Bowl guard pulse drain PKBBGB Metal bowl / w/o sight gauge pulse drain PKBBMB µ particle filter element PKAESE Panel mount nut - aluminum PKAMM Panel mount nut - plastic PKAMP Angle bracket (attaches via panel nut) PKBMR C-bracket (fits to body) PKAMW T-bracket with body connector PKAMT Body connector PKACB.9 (.9). (.) Gauges Square flush mount gauge - bar KSCRB - bar KSCRB - psig KSCR - psig KSCR mm (/) I.D. tube barb fitting Manual Drain Bowl removal (.) clearance. Square (.) Gauge Pulse Drain For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. Square with adapter kit - bar PG-PR - bar PG-PR - psig PG-PR9 - psig PG-PR9
46 -UK P Series Compact Filter / Regulator - P Symbols Integral /", /8" or /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Options: PEB E N P Basic series Global modular compact filter / regulator PEB Thread type BSPP NPT 9 Element µ Element E B N Relief Relieving Non-relieving P Mounting Plastic panel mount nut Bold items are most common. Port size / /8 / Bowl type Poly bowl with bowl guard Metal bowl with sight gauge G S M A Drain type Manual drain Auto drain Adjustment range With square gauge With round gauge psig bar Z bar; psig;. MPa = * V = * M bar; psig;. MPa = S = G 8 bar; psig;.8 MPa = T = 8 J bar; psig;. MPa Without gauge Y bar; psig;. MPa * Unit comes with - bar or - psig L bar; psig;. MPa gauge respectively. N 8 bar; psig;.8 MPa Not available with poly bowl with bowl guard. H bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving - poly bowl - manual drain (89) (). (.) (.) 9 (.) PEBEGMBNGP /" 8 bar ( psig) relieving - poly bowl - auto drain (89) (). (.) (.) 9 (.) PEBEGABNGP /" 8 bar ( psig) relieving - metal bowl - manual drain (89) (). (.) (.) 9 (.) PEBESMBNGP /" 8 bar ( psig) relieving - metal bowl - auto drain (89) (). (.) (.) 9 (.) PEBESABNGP /8" 8 bar ( psig) relieving - poly bowl - manual drain 8 () (). (.) (.) 9 (.) PEBEGMBNGP /8" 8 bar ( psig) relieving - poly bowl - auto drain 8 () (). (.) (.) 9 (.) PEBEGABNGP /8" 8 bar ( psig) relieving - metal bowl - manual drain 8 () (). (.) (.) 9 (.) PEBESMBNGP /8" 8 bar ( psig) relieving - metal bowl - auto drain 8 () (). (.) (.) 9 (.) PEBESABNGP /" 8 bar ( psig) relieving - poly bowl - manual drain () (). (.) (.) 9 (.) PEBEGMBNGP /" 8 bar ( psig) relieving - poly bowl - auto drain () (). (.) (.) 9 (.) PEBEGABNGP /" 8 bar ( psig) relieving - metal bowl - manual drain () (). (.) (.) 9 (.) PEBESMBNGP /" 8 bar ( psig) relieving - metal bowl - auto drain () (). (.) (.) 9 (.) PEBESABNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
47 -UK P Series Specifications Flow capacity* / dm /s (89 scfm) /8 8 dm /s ( scfm) / dm /s ( scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration micron Useful retention cm (. US oz.) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, /8, / Gauge port ( ea.) BSPP / NPT / Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates); Class (Particulates) Material Specifications Body Aluminum Adjustment knob Acetal Element retainer / Baffle Acetal Bowl Plastic bowl Polycarbonate Metal bowl Zinc Bowl guard Nylon Filter element Sintered polyethylene Seals Nitrile Springs Main regulating / valve Steel / S.S. Valve assembly Brass / Nitrile Diaphragm assembly Nitrile / Zinc Panel nut Acetal Sight gauge Metal bowl Polycarbonate Dimensions Flow Charts / Filter / Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar /8 Filter/Regulator Secondary Pressure - (psig) 8 / Filter/Regulator Secondary Pressure - (psig) Repair and Service Kits. bar. psig. bar 8 psig. bar 9. psig 8. bar psig 8 Flow - dm /s 8 Flow - (SCFM) Inlet Pressure - bar ( psig) Secondary Pressure - bar Secondary Pressure - bar 9 8. bar. psig. bar 9. psig. bar 8 psig 8. bar psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig 8 9 Flow - dm /s 8 8 Flow - (scfm) (.). (.) 9 Round (.) Gauge (.) (.8) 9. (.8). (.) Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / Sight gauge manual drain PKBBSM Auto drain PKADA µ particle filter element PKAESE Panel mount nut - aluminum PKAMM Panel mount nut - plastic PKAMP Angle bracket (fits to panel mount threads) PKBMR T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB Manual Drain mm (/) I.D. tube barb fitting! Bowl 8 removal (.8) clearance WARNING 8 Square (.9) Gauge Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. Automatic Drain Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.
48 -UK P Series Compact Semi-Precision Filter / Regulator - P Symbols Options: Integral /", /8" or /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation PEB E N P Basic series Global modular compact filter / regulator PEB Thread type BSPP NPT 9 Element µ Element E P E Relief Relieving Non-relieving P Mounting Plastic panel mount nut Bold items are most common. Port size / /8 / Bowl type Poly bowl with bowl guard Metal bowl with sight gauge G S M A Drain type Manual drain Auto drain Not available with poly bowl with bowl guard. Z M G J Y L N H Adjustment range With round gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Without gauge bar; psig;. MPa bar; psig;. MPa 8 bar; psig;.8 MPa bar; psig;. MPa Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving - poly bowl - manual drain () (). (.) (.) 9 (.) PEBEGMPNGP /" 8 bar ( psig) relieving - poly bowl - auto drain () (). (.) (.) 9 (.) PEBEGAPNGP /" 8 bar ( psig) relieving - metal bowl - manual drain () (). (.) (.) 9 (.) PEBESMPNGP /" 8 bar ( psig) relieving - metal bowl - auto drain () (). (.) (.) 9 (.) PEBESAPNGP /8" 8 bar ( psig) relieving - poly bowl - manual drain () (). (.) (.) 9 (.) PEBEGMPNGP /8" 8 bar ( psig) relieving - poly bowl - auto drain () (). (.) (.) 9 (.) PEBEGAPNGP /8" 8 bar ( psig) relieving - metal bowl - manual drain () (). (.) (.) 9 (.) PEBESMPNGP /8" 8 bar ( psig) relieving - metal bowl - auto drain () (). (.) (.) 9 (.) PEBESAPNGP /" 8 bar ( psig) relieving - poly bowl - manual drain () (). (.) (.) 9 (.) PEBEGMPNGP /" 8 bar ( psig) relieving - poly bowl - auto drain () (). (.) (.) 9 (.) PEBEGAPNGP /" 8 bar ( psig) relieving - metal bowl - manual drain () (). (.) (.) 9 (.) PEBESMPNGP /" 8 bar ( psig) relieving - metal bowl - auto drain () (). (.) (.) 9 (.) PEBESAPNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop. 8
49 -UK P Series Specifications Flow capacity* / dm /s ( scfm) /8 dm /s ( scfm) / dm /s ( scfm) Effect of supply pressure variation. bar (. PSIG) for. bar ( PSIG) change in P Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration micron Useful retention cm (. US oz.) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, /8, / Gauge port ( ea.) BSPP / NPT / Weight. kg (. lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates); Class (Particulates) Material Specifications Body Aluminum Adjustment knob Acetal Element retainer / Baffle Acetal Bowl Plastic bowl Polycarbonate Metal bowl Zinc Bowl guard Nylon Filter element Sintered polyethylene Seals Nitrile Springs Main regulating / valve Steel / S.S. Valve assembly Brass / Nitrile Diaphragm assembly Nitrile / Zinc Panel nut Acetal Sight gauge Metal bowl Polycarbonate Flow Charts / Filter / Regulator Secondary Pressure - (psig) 8 /8 Filter/Regulator Secondary Pressure - (psig) 8 / Filter/Regulator Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar Secondary Pressure - bar bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s 8 Flow - (scfm) Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s 8 Flow - (scfm) Inlet Pressure - bar ( psig) bar psig. bar 9. psig. bar 8 psig. bar. psig Flow - dm /s 8 Flow - (scfm) Secondary Pressure - bar Dimensions Repair and Service Kits (.). (.) 9 Round (.) Gauge (.) (.8) 9. (.8). (.) Plastic bowl / Bowl guard manual drain PKBBGM Metal bowl / Sight gauge manual drain PKBBSM Auto drain PKADA µ particle filter element PKAESE Panel mount nut - aluminum PKAMM Panel mount nut - plastic PKAMP Angle bracket (fits to panel mount threads) PKBMR T-bracket (fits to body connector) PKAMB T-bracket with body connector PKAMT Body connector PKACB Manual Drain mm (/) I.D. tube barb fitting! Bowl 8 removal (.8) clearance WARNING 8 Square (.9) Gauge Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating. Automatic Drain Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting. 9
50 -UK P Series Standard Filter / Regulator - P Symbols Integral /" or /" ports (NPT & BSPP) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction Positive bayonet latch to ensure correct & safe fitting Secondary pressure ranges - bar (- psig), - bar, (- psig), -8 bar (- psig), - bar (- psig) Secondary aspiration plus balanced poppet provides quick response and accurate pressure regulation Options: PEA E N P Basic series Global modular standard filter / regulator PEA Thread type BSPP NPT 9 Element µ Element E B N Relief Relieving Non-relieving P Mounting Plastic panel mount nut Bold items are most common. Port size / / Bowl type Poly bowl with bowl guard Metal bowl with sight gauge G S M A Drain type Manual drain Auto drain Adjustment range With round gauge Z bar; psig;. MPa M bar; psig;. MPa G 8 bar; psig;.8 MPa J bar; psig;. MPa Without gauge Y bar; psig;. MPa L bar; psig;. MPa N 8 bar; psig;.8 MPa H bar; psig;. MPa Not available with poly bowl with bowl guard. Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" 8 bar ( psig) relieving - poly bowl - manual drain 99 () () 9 (.) (.8) 8 (.) PEAEGMBNGP /" 8 bar ( psig) relieving - poly bowl - auto drain 99 () () 8 (.) (.8) 8 (.) PEAEGABNGP /" 8 bar ( psig) relieving - metal bowl - manual drain 99 () () 9 (.) (.8) 8 (.) PEAESMBNGP /" 8 bar ( psig) relieving - metal bowl - auto drain 99 () () 8 (.) (.8) 8 (.) PEAESABNGP /" 8 bar ( psig) relieving - poly bowl - manual drain 8 () () 9 (.) (.8) 8 (.) PEAEGMBNGP /" 8 bar ( psig) relieving - poly bowl - auto drain 8 () () 8 (.) (.8) 8 (.) PEAEGABNGP /" 8 bar ( psig) relieving - metal bowl - manual drain 8 () () 9 (.) (.8) 8 (.) PEAESMBNGP /" 8 bar ( psig) Relieving - Metal bowl - Auto drain 8 () () 8 (.) (.8) 8 (.) PEAESABNGP Standard part numbers shown in bold. For other models refer to Options chart above. Flow with bar ( psig) inlet pressure,. bar (9.) psig) set pressure and bar (. psig) pressure drop.
51 -UK P Series Specifications Flow capacity* / 99 dm /s ( scfm) / 8 dm /s ( scfm) Operating Plastic bowl - C to C (- F to F) temperature Metal bowl - C to. C (- F to F) Supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Standard filtration micron Useful retention 8 cm (.8 US oz.) Adjusting range pressure - bar ( psig) - bar ( psig) -8 bar ( psig) - bar ( psig) Port size BSPP / NPT /, / Gauge port ( ea.) BSPP / NPT / Weight.8 kg (.8 lbs) * Inlet pressure bar ( psig). Secondary pressure. bar (9. psig). Useful retention refers to volume below the quiet zone baffle. Air quality: Within ISO 8-: 99 Class (Particulates); Class (Particulates) Material Specifications Body Aluminum Adjustment knob Acetal Body cap ABS Element retainer / Baffle Acetal Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Filter element Sintered Polyethylene Seals Nitrile Springs Main regulating / Valve Steel / S.S. Valve assembly Brass / Nitrile Diaphragm assembly Nitrile / Zinc Panel nut Acetal Sight gauge Metal bowl Polycarbonate Dimensions (.8) (.) 8 Round (.) Gauge (.8) (.9) Flow Charts / Filter / Regulator Secondary Pressure - (psig) Secondary Pressure - (psig) 8 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar 9 8 / Filter/Regulator. bar 9. psig. bar. psig 8. bar psig. bar 8 psig 8 9 Flow - dm /s 8 8 Flow - (scfm) Repair and Service Kits Plastic bowl / Bowl guard manual drain Metal bowl / Sight gauge manual drain Auto drain Inlet Pressure - bar ( psig) Secondary Pressure - bar 9 8 PKABGM PKABSM PKADA µ particle filter element PKAESE Panel mount nut - Aluminum Panel mount nut - Plastic Angle bracket (fits to panel mount threads) T-bracket (fits to body connector) T-bracket with body connector Body connector 8. bar psig. bar. psig PKAMM PKAMP PKAMR PKAMB PKAMT PKACB. bar 9. psig. bar 8 psig 8 9 Flow - dm /s Flow - (scfm) 9 (.) 8 (.) Gauges mm (") Round /" center back mount - psig / - bar PG-ERB - psig / - bar PG-ERB - psig / - bar PG-ERB Manual Drain mm (/) I.D. tube barb fitting Bowl removal clearance (.) (Manual & Auto Drain) (.8) Use mm or /8" Flex Tubing Automatic Drain For best performance, regulated pressure should always be set by increasing the pressure up to the desired setting.! WARNING Product rupture can cause serious injury. Do not connect regulator to bottled gas. Do not exceed Maximum primary pressure rating.
52 -UK P Series Mini Lubricator - P Symbol Lubricator with drain Integral /" ports (NPT & BSPP) Robust but lightweight aluminum construction Proportional oil delivery over a wide range of air flows Finger tip ratchet control for precise oil drip rate adjustment Options: PLB L N N Basic series Global modular mini lubricator PLB Thread type BSPP NPT 9 Mounting N No bracket Drain type Port size / N No drain closed end Bowl type G Poly bowl with bowl guard Bold items are most common. Lube type Oil mist standard sight dome L M Metal bowl without sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - No drain 9 () (). (.) (.8) (.8) PLBLGNN /" Metal bowl - No drain 9 () (). (.) (.8) (.8) PLBLMNN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. bar (.9 psig) pressure drop.
53 -UK P Series Specifications Flow capacity* / 9 dm /s ( scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Useful retention 8 cm (. US oz.) Port size BSPP / NPT / Weight. kg (.9 lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Material Specifications Body Body cap Aluminum ABS Bowl Plastic bowl Polycarbonate Metal bowl Aluminum Seals Sight dome Suggested lubricant Pick-up filter Nitrile Polycarbonate ISO / ASTM VG Sintered bronze Flow Charts PLB /" Lubricator Pressure Drop - (psig) Pressure Drop - bar..... Primary Pressure - bar. Primary Pressure - psig.. 9. Flow - dm /s 8 Flow - (scfm) Dimensions Repair and Service Kits (.8). (.) (.8) (.9). (.) Plastic bowl / Bowl guard no drain Metal bowl / w/o sight gauge no drain Drip control assembly Fill plug C-bracket (fits to body) T-bracket with body connector Body connector Lubricator oil - VG: ISO 8 - ml Lubricator oil - VG - litre PKBBGN PKBBMN PKAPG PKAPL PKAMW PKAMT PKACB PXKAPPA PYKAPPBB Bowl removal (.) clearance (DO NOT USE OILS WITH ADDITIVES, COMPOUNDED OILS CONTAINING SOLVENTS, GRAPHITE, DETERGENTS, OR SYNTHETIC OILS.)
54 -UK P Series Compact Lubricator - P Symbol Lubricator with drain Integral /", /8" or /" ports (NPT & BSPP) Robust but lightweight aluminum construction Proportional oil delivery over a wide range of air flows Finger tip ratchet control for precise oil drip rate adjustment Fill from top under system pressure Options: PLB L N N Basic series Global modular compact lubricator PLB Thread type BSPP NPT 9 Mounting N No bracket Drain type Port size / /8 / G S N No drain closed end Bowl type Poly bowl with bowl guard Metal bowl with sight gauge Bold items are most common. Lube type Oil mist standard sight dome L Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - No drain () (). (8.) (.) (.) PLBLGNN /" Metal bowl - No drain () (). (8.) (.) (.) PLBLSNN /8" Poly bowl - No drain () (). (8.) (.) (.) PLBLGNN /8" Metal bowl - No drain () (). (8.) (.) (.) PLBLSNN /" Poly bowl - No drain (9) (). (8.) (.) (.) PLBLGNN /" Metal bowl - No drain (9) (). (8.) (.) (.) PLBLSNN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. bar (.9 psig) pressure drop.
55 -UK P Series Specifications Flow capacity* / dm /s (8 scfm) /8 dm /s ( scfm) / dm /s (9 scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Useful retention cm (.9 US oz.) Port size BSPP / NPT /, /8, / Weight. kg (.8 lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Material Specifications Body Body cap Aluminum ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Seals Sight dome Nitrile Polycarbonate Sight gauge Metal bowl Polycarbonate Suggested lubricant Pick-up filter ISO / ASTM VG Sintered bronze Flow Charts / Lubricator Pressure Drop - (psig) Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar /8 Lubricator Primary Pressure - bar Primary Pressure - psig / Lubricator Flow - dm /s Flow - (scfm) Primary Pressure - bar Primary Pressure - psig Flow - dm /s 8 Flow - (scfm) Dimensions (.) (.) (.8) Pressure Drop - (psig) Pressure Drop - bar Primary Pressure - bar Primary Pressure - psig (.) 8 Flow - dm /s 8 Flow - (scfm) Repair and Service Kits. (8.) Bowl 8 removal (.8) clearance Plastic bowl / Bowl guard no drain Metal bowl / w/o sight gauge no drain Metal bowl / Sight gauge no drain Drip control assembly Fill plug L-bracket (fits to body) T-bracket (fits to body connector) T-bracket with body connector Body connector PKBBGN PKBBMN PKBBSN PKAPG PKAPL PKAML PKAMB PKAMT PKACB (DO NOT USE OILS WITH ADDITIVES, COMPOUNDED OILS CONTAINING SOLVENTS, GRAPHITE, DETERGENTS, OR SYNTHETIC OILS.)
56 -UK P Series Standard Lubricator - P Symbol Lubricator with drain Integral /" or /" ports (NPT & BSPP) Robust but lightweight aluminum construction Proportional oil delivery over a wide range of air flows Finger tip ratchet control for precise oil drip rate adjustment Fill from top under system pressure Options: PLA L N N Basic series Global modular standard lubricator PLA Thread type BSPP NPT 9 Mounting N No bracket Drain type Port size / / G N No drain closed end Bowl type Poly bowl with bowl guard Bold items are most common. Lube type Oil mist standard sight dome L S Metal bowl with sight gauge Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Part number /" Poly bowl - No drain () () (9.) (.9) (.9) PLALGNN /" Metal bowl - No drain () () (9.) (.9) (.9) PLALSNN /" Poly bowl - No drain () () (9.) (.9) (.9) PLALGNN /" Metal bowl - No drain () () (9.) (.9) (.9) PLALSNN Standard part numbers shown in bold. For other models refer to Options chart above. Flow with. bar (9. psig) inlet pressure and. bar (.9 psig) pressure drop.
57 -UK P Series Specifications Flow Charts Flow capacity* / dm /s ( scfm) / dm /s ( scfm) Operating Plastic bowl - C to C ( F to F) temperature Metal Bowl - C to. C ( F to F) Max. supply Plastic bowl bar ( psig) pressure Metal bowl bar ( psig) Useful retention 8 cm (. US oz.) Port size BSPP / NPT /, / Weight. kg (. lbs) * Inlet pressure. bar (9. psig). Pressure drop. bar (.9 psig). Material Specifications Body Body cap Aluminum ABS Bowls Plastic bowl Polycarbonate Metal bowl Aluminum Seals Sight dome Nitrile Polycarbonate Sight gauge Metal bowl Polycarbonate Suggested lubricant Pick-up filter ISO / ASTM VG Sintered bronze / Lubricator Pressure Drop - (psig) Pressure Drop - (psig) Pressure Drop - bar Pressure Drop - bar Primary Pressure - bar Primary Pressure - psig..... / Lubricator Flow - dm /s 8 8 Flow - (scfm) Primary Pressure - bar Primary Pressure - psig Flow - dm /s 8 8 Flow - (scfm) Dimensions Repair and Service Kits (.9) (.) (9.) (.9) (.) Plastic bowl / Bowl guard no drain Metal bowl / w/o sight gauge no drain Metal bowl / Sight gauge no drain Drip control assembly Fill plug L-bracket (fits to body) T-bracket (fits to body connector) T-bracket with body connector Body connector Lubricator oil - VG: ISO 8 - ml Lubricator oil - VG - litre PKABGN PKABMN PKABSN PKAPG PKAPL PKAML PKAMB PKAMT PKACB PXKAPPA PYKAPPBB (DO NOT USE OILS WITH ADDITIVES, COMPOUNDED OILS CONTAINING SOLVENTS, GRAPHITE, DETERGENTS, OR SYNTHETIC OILS.) Bowl (.) removal clearance
58 -UK Proportional Regulators Proportional Regulators - PP & PP PP Series Bottom exhaust PP Series Bottom exhaust Very fast response times Accurate output pressure Micro parameter settings Selectable I/O parameters Quick, full flow exhaust LED display indicates output pressure No air consumption in steady state Multiple mounting options Protection to IP PP flows to 9 dm/s ( scfm) PP flows to dm/s ( scfm) Options: PPA A Body size Global modular mini (/") Global modular compact (/") Bold items are most common. PPA PPA Thread type BSPP NPT 9 Port size Global modular mini (/") Global modular compact (/") Version Bottom ported exhaust (NC) Bottom ported forced exhaust (NO) Side ported exhaust (NC) Side ported forced exhaust (NO) A E B C When the supply voltage is lost the unit will automatically exhaust the regulated pressure to bar (atmospheric pressure) Z S D Power supply volts Pressure range - bar (-9 PSIG) - bar (- PSIG) - bar (- PSIG) Control signal V -V A - ma Input connector M (-pin) Output signal D Digital, PNP P PNP or -V N NPN or -V M -ma fixed D) Digital PNP output only, no analog output selectable P) Digital PNP and analogue -V outputs selectable, by means of parameter. (Factory default -V) N) Digital NPN and analog - V outputs selectable by means of parameter. Factory default -V) M) Analog -ma output only. Note: On all analog outputs the F.S. value can be adjusted by means of parameter 8. PP Mounting brackets PP Mounting brackets Description Part number Description Part number L-Bracket mounting kit PHKAML L-Bracket mounting kit PKKAML Foot bracket mounting kit PHKAMC Foot bracket mounting kit PKKAMC L-Bracket Foot Bracket L-Bracket Foot Bracket Cables Description Part number mtr. cable with moulded straight Mx connector P8L-MCAA-M mtr. cable with moulded 9 degree Mx connector P8L-MCRA-M Note: These brackets fit both Proportional Regulators and Combined Soft Start & Dump Valves. Dimensions see page 8. 8
59 -UK Proportional Regulators Technical Information Working medium Compressed air or inert gasses, filtered to µ. Supply pressure Max. Operating Pressure: bar unit:... bar (. psig) bar unit:.... bar ( psig) Min. Operating Pressure... P Pressure +. bar (. psig) Pressure control range Available in three pressure ranges, - bar (-9 psig), - bar (-. psig) or - bar (- psig). Pressure range can be changed through the software at all times. (parameter 9) Temperature range C up to + C ( F up to F) Weights: PP =.9 kg (. lbs) PP =. kg (. lbs) Air consumption No consumption in stable regulated situation. Display The regulator is provided with a digital display, indicating the output pressure, either in bar or psig. The factory setting is as indicated on the label, can be changed through to software at all times (parameter ) Supply voltage VDC +/- % Power consumption Max..W with unloaded signal outputs Control signals The electronic pressure regulator can be externally controlled through an analogue control signal of either -V or -ma. (parameter ). Output signals As soon as the output pressure is within the signal band a signal is given of VDC, PNP Ri = kohm Outside the signal band this connection is V. Connections (In case of output signal (Option D) Central M connector -pole The electrical connections are as follows: Pin No. Function Color V Supply Brown to V Control Signal Ri = k W to ma Control Signal Ri = W White V (GND) Supply Blue V Alarm Output Signal Black Schematic 9
60 -UK Proportional Regulators Technical information Dead band The dead band is preset at.% of Full Scale*, adjustable via parameter. Accuracy Linearity: = <.% of Full Scale.* Proportional band The proportional band is preset at % of Full Scale.* Fail safe operation If the PP / PP unit has an or A in the th digit of the model number When the supply voltage drops, the electronic control reverts to the fail safe mode. The last known output pressure is maintained at approximately the same level depending upon air consumption. The digital display indicates the last known pressure setting. When the supply voltage is reinstated to the correct level, the valve moves from the fail safe mode and the output pressure immediately follows the control signal requirement. The display indicates the actual output pressure. Note: In the event of loss of both power and inlet pressure the unit will exhaust downstream pressure. If the PP / PP unit has an E in the th digit of the model number When the supply voltage drops, the electronic control reverts to Forced Exhaust Mode and will automatically exhaust the downstream (regulated) pressure. When the supply voltage is reinstated to the correct level the unit will return to normal operation and follows the control signal requirement. The display indicates the actual pressure. If the unit has been programmed in manual mode (not with a control signal) the unit will EXHAUST and the regulator will need to be reset when power is applied. Full exhaust Complete exhaust of the regulator is defined as P % Full Scale * Full scale (F.S.) For bar (9 psig) versions this will be bar (9 psig), for the bar ( psig) version full scale will be bar ( psig). Degree of protection IP EU conformity CE: standard EMC: according to directive 89//EEC The new pressure regulator is in accordance with: EN --: EN --: EN --: EN --: These standards ensure that this unit meets the highest level of EMC protection. Mounting position Preferably vertical, with the cable gland on top. Materials: PP & PP Magnet Core...Steel Solenoid Valve Poppet... FPM Solenoid Valve Housing...Techno Polymer Regulator Body (PP & PP versions)... Aluminum Regulator Top Housing...Nylon Valve Head... Brass & NBR Remaining Seals... NBR Advanced functionality Pilot valve protection When the required output pressure can not be achieved because of a lack of input pressure the unit will open fully and will display NoP. Approximately every seconds the unit will retry. The output pressure will then be approximately equal to the inlet pressure. As soon as the input pressure is back on the required level, the normal control function follows. Safety exhaust Should the control signal fall below. volts the valve will automatically dump downstream system pressure. Input protection The unit has built-in protection against failure and burnout resulting from incorrect input value, typically: The VDC supply is incorrectly connected to the setpoint input, the display will show OL, as an overload indication. The unit will need to be rewired and when correctly connected will operate normally. The overload indicator OL will also appear should the wrong input value be applied or the wrong input value be programmed: - m instead of - V. To correct this a different set point value should be input or the unit reprogrammed to correct the set point value acceptance. (via parameter ). Response time PP PP to bar msecs msecs to bar msecs msecs to bar msecs 8 msecs to bar 8 msecs msecs To fill volume of: cm - PP cm - PP connected to the outlet of the regulator. Settings The regulator is pre-set at the factory. If required, adjustments can be made. Flow Charts PP Regulator / Ports Secondary Pressure - (psig) 8 Inlet Pressure - bar ( psig) Secondary Pressure - bar 9 8 PP Regulator / Ports Secondary Pressure - (psig) 8 Flow - dm /s Flow - (scfm) Inlet Pressure - bar ( psig) Secondary Pressure - bar Flow - dm /s 8 8 Flow - (scfm)
61 -UK Proportional Regulators How to change parameters Pressing the Accept key acc for more than seconds, will activate parameter change mode. The user can then select the parameters by pressing up or down key. (display will show Pxx). When parameter number is correct, pressing accept again will enter parameter number.(display will show parameter value). Pressing the up or down key will change the parameter itself. (display will flash indicating parameter editing mode). Pressing the accept key will accept the new parameter value. (all digits will flash whilst being accepted). After releasing all keys, the next parameter number will be presented on the display. (you may step to the next parameter). When no key is pressed, after seconds the display will show the actual output pressure. When the unit is initially powered up allow approximately seconds for the unit to boot-up before changing parameter settings. Only parameter numbers,,, 8, 9,, 8, 9,,, and are accessible to edit. All other parameters are fixed. Manual mode: When keys DOWN and UP are pressed during startup, (connecting to the V power supply) manual mode is activated. This means that the user is able to in/decrease the output pressure of the regulator, by pressing the UP or DOWN key. During this action the display will blink, indicating that the manual mode is activated. After powering up again, the unit will revert back to normal mode. Back to Factory Setting After start up. (Power is on) Entering this value in parameter will store the calibrated factory data into the working parameters. (Default calibration data is used) Parameter Number Reset Back to Factory Settings Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. Edits parameter. = standard factory settings. If other than, use Up or Down Arrow and accept Accepts and saves new parameter setting. Sequences to next parameter. Set Control Signal The unit is factory set for - V control signal. If - ma control signal is required, change parameter. Parameter Number Set Control Signal in Volts or Milliamps Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. = V = ma Edits parameter. Accepts and saves new parameter setting. Sequences to next parameter.
62 -UK Proportional Regulators Set Output Signal Parameter is used to set the type of output signal to your PLC. This parameter is used as follows: Output Signal option = Digital Output PNP Factory set at Non Adjustable Output Signal option P = Digital PNP or Analog -V Factory set at for Analog Signal Convert to Digital PNP by changing parameter to setting Output Signal option N = Digital NPN or Analog -V Factory set at Analog Signal Convert to Digital NPN by changing parameter to Output Signal option M = Analog - ma Factory set at Non Adjustable Parameter Number Set Output Signal Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (Value, or ) Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. = m factory default for PH with analog options Edits parameter. = digital (NPN or PNP) = analog..v = analog.. ma Accepts and saves new parameter setting. Sequences to next parameter. Adjust Span Analog Output Signal Set value is a % of Full Analog range. As an example for a -V output signal, the original factory setting of % will give you an adjustment of -V. If you reset Parameter 8 to %, the new output range would be -V or % of the full range. In the event that the output signal is to low, in a certain application, you can adjust it by increasing Parameter 8 to a maximum value of % of scale. Note that all values are nominal and that an actual measurement may be required to ensure signal strength. Parameter Number 8 Adjust Span Analog Output Signal Step Press or or - seconds Until Display Reads Flashing Decimal (For bar versions value = 9) Flashing Decimal (Value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no. 8. Displays current parameter value. Edits parameter. Accepts and saves new parameter setting and implements the new analog signal span. Sequences to next parameter.
63 -UK Proportional Regulators Adjust Digital Display If necessary, adjustments can be made to the digital display when using an external pressure sensor. Parameter Number 9 Adjust Digital Display Value (Pressure Calibration) Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal Flashing Description Accesses changeable parameters. Accesses parameter no. 9. Displays current digital display Use up or down arrows and accept to adjust the display value if using an external pressure sensor. Accepts and saves new parameter setting. Sequences to next parameter. Set Pressure Scale Units with NPT port threads are supplied with a factory set psig pressure scale. Use parameter to change scale to bar. Parameter Number Set Pressure Scale in psig or bar Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. = psig = bar = MPA Edits parameter. Accepts and saves new parameter setting. Sequences to next parameter.
64 -UK Proportional Regulators Preset Minimum Pressure If there is a need for a pre-set Minimum pressure, use parameter 8. (Note: preset pressure is affected by % P9.) Parameter Number 8 Set Minimum Preset Pressure Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no. 8. Displays current parameter value. Incremental value is: bar unit: x mbar x % P9 bar unit: x mbar x % P9 Edits parameter. Accepts and saves new parameter setting. Sequences to next parameter. Set Pressure Correction Pressure correction allows the user to set a Maximum pressure as a percentage of secondary pressure F.S. Example: If F.S. is bar, set parameter 9 to for Maximum preset pressure of bar. Pressure correction also affects the Minimum preset pressure in parameter 8. Example: If F.S. is bar and parameter 8 is set to a value of ( bar), and parameter 9 is set to %, then the actual Minimum preset pressure seen is. bar. Parameter Number 9 Set Maximum Preset Pressure Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no. 9. Displays current parameter value. Incremental value is: % of F.S. Edits parameter. Accepts and saves new parameter setting. Sequences to next parameter.
65 -UK Proportional Regulators Behavior Control The regulation speed of the pressure regulator can be modified by means of one parameter. (P ) The value in this parameter has a range from -. A higher value indicates slower regulation speed, but will be more stable. Parameter Number Set Behavior Control Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. Edits parameter = custom set* = fastest (narrow proportional band) = fast = normal = slow = slowest (proportional band is broad) Accepts and saves new parameter setting. Sequences to next parameter. * When the value is entered, you are able to create your own custom settings true parameters, and. Fine Settings Set Proportional Band Proportional band is used for setting the reaction sensitivity of the regulator. The displayed value is X mbar and has a range between (. bar) and (. bar). Parameter Number Set Proportional Band (P Must be Set to ) Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. Incremental value is: x mbar Edits parameter. Accepts and saves new parameter setting. Sequences to next parameter.
66 -UK Proportional Regulators Set Deadband Deadband is the Minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X mbar and has a range between ( mbar) and ( mbar). Parameter Number Set Deadband (P Must be Set to ) Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. Incremental value is x mbar Edits parameter. Accepts and saves new parameter Sequences to next setting. parameter. Proportional Effect Parameter Number Set Proportional Effect (P Must be Set to ) Step Press or or - seconds Until Display Reads Flashing Decimal Flashing Decimal (value between and ) Flashing Description Accesses changeable parameters. Accesses parameter no.. Displays current parameter value. Edits parameter. = fastest regulation = slowest regulation. Accepts and saves new parameter setting. Sequences to next parameter. Parameter Number 9 Displays Current Software Version Step Press or - seconds Until Display Reads Flashing Decimal Description Accesses changeable parameters. Accesses parameter no. 9. Displays current parameter value. XXX = current software version
67 -UK Proportional Regulators PP PP. (.) pin M Connector. (.) pin M Connector. (.). (.99) 89 (.). (.9). (.). (.) 8. (.) (.) (.9) (.8). (.8) (.9) 8. (.). (.) (.9) 8. (.) L-Bracket L-Bracket (.8) (.9) (.98) (.9) (.98) (.8) (.8) (.) (.8) (.8) (.9) (.8) (.) (.9) (.) Foot Bracket Foot Bracket (.) (.) (.) (.) (.9) (.) (.) (.) (.) (.)(.) Ø (.8) holes (.) (.) Ø (.8) holes 8 (.) (.9) 8 (.) (.9) Dimensions are in mm (Inches)
68 -UK PD / PD Series Dump Valve Symbol Modular design with /" or /" integral ports (NPT & BSPP) The -way, -position function automatically dumps downstream pressure on the loss of pilot signal Solenoid or air pilot options High flow & exhaust capability Silencer included Remotely operated dump valves automatically shut off upstream pressure and exhaust the downstream pressure when the pilot pressure is released. To maintain these units in the open position a pilot supply to the air pilot operated version or an electrical signal to the solenoid operated version must be maintained. The valve will automatically dump when the holding signal is removed. Options: PDA N Solenoid type only Body size Dump valve (/") Dump valve (/") Note: P unit used for both P & P series Bold items are most common. PDA PDA Thread type BSPP NPT 9 Port size Global modular mini (/") Global modular compact (/") Pilot type P External air pilot S Solenoid pilot Actuator interface G mm solenoid (P only) C mm solenoid P Threaded Air Pilot C A D Solenoid voltage Solenoid / Coil not fitted CN VDC non locking manual overide GN VAC non locking manual overide FN VAC non locking manual override (P series only) Solenoid type None (For P series - operator is fitted to valve) mm (P series only) mm CNOMO coil (P only) mm CNOMO coil (M connection) (P only) Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Weight kg (lbs) Part number /" Solenoid operated (not included) () (). (.) (.) (.). (.8) PDASGN /" VDC Solenoid & cable plug () () (.) (.) (.). (.9) PDASGNCCN /" External air pilot operated () (). (.) (.) (.). (.8) PDAPPN /" Solenoid operated (not included) (8) (). (.) (.9). (.).9 (.) PDASCN /" VDC mm coil & cable plug incl. (8) (). (8.9) (.9). (.).9 (.) PDASCNACN /" External air pilot operated (8) (). (.) (.9). (.).8 (.9) PDAPPN Includes exhaust silencer Standard part numbers shown in bold. For other models refer to Options chart above. 8
69 -UK PD / PD Series Technical Information Fluid: Max. pressure solenoid operated: Max. pressure air pilot operated: Min. operating pressure: Compressed air bar ( psig) bar ( psig) bar ( psig) Temperature Max.* solenoid operated: - C to C ( F to F) Temperature Max.* air pilot operated: - C to 8 C (- F to F) Air pilot port: /8" Exhaust port: PD - /" / PD - /" Gauge port: PD - /8" / PD - /" Typical flow with. bar inlet pressure and bar PD dm /s ( scfm) pressure drop: PD dm /s (8 scfm) * Air supply must be dry enough to avoid ice formation at temperatures below + C Snap pressure: Full flow when downstream pressure reaches % of the inlet pressure Material Specifications Body: Body cover: Seals: Mounting Brackets Description L-bracket mounting kit Foot bracket mounting kit Aluminum Polyester Nitrile NBR Part number PD PHKAML PHKAMC Flow Charts PDA /" Remote Dump Valve Secondary Pressure - (psig) Secondary Pressure - bar Inlet Pressure -. bar (9. psig) 8 PDA /" Remote Dump Valve Secondary Pressure - (psig) 8 8 Secondary Pressure - bar. bar 8 psig. bar. bar. psig 8 psig. bar. psig bar 9. bar psig. psig Flow - dm /s 8 Flow - (scfm) Inlet Pressure -. bar (9. psig) 8. bar. psig. bar 8 psig. bar. psig. bar 9. psig. bar 9. psig. bar 8 psig bar. psig bar. psig 8. bar psig 8. bar psig 9. bar. psig bar psig 8 Flow - dm /s 8 8 Flow - (scfm) Note: For solenoid operators and cable plugs (connectors) see pages to. Dimensions PD PD (.8) (.) (.) (.) 8 (.). (.) /8" Gauge Port. (.). (8.9). (.8) 9. (.) /" Gauge Port (.) (.) (.8) (.) (.9). (.) (.) For mounting brackets see page 8. (.9) (.) 9
70 -UK PS / PS Series Soft Start Valve Symbol Modular design with /" or /" integral ports (NPT & BSPP) The -way, -position function provides for the safe introduction of pressure Adjustable slow start Solenoid or air pilot options High flow Parker Global Series Soft Start Valves, provide for the safe introduction of pressure to machines or systems. Soft Start Valves, allow the pressure to gradually build to the set point before fully opening to deliver full flow at line pressure. Options: The controlled introduction of pressure can be an important safety factor and prevent damage to tooling when air pressure is introduced at machine or system start up. Note: Soft Start Valves must be installed downstream of a / valve with exhaust capability PSA N Solenoid type only Body size Soft start Soft start Note: P unit used for both P & P series Bold items are most common. PSA PSA Thread type BSPP NPT 9 Port size Global modular mini (/") Global modular compact (/") Actuator interface Internal Pilot G mm solenoid (P only) C mm solenoid P* Threaded air pilot Pilot type P External air pilot S Solenoid pilot Y Internal air pilot C A D Solenoid voltage Solenoid / Coil not fitted CN VDC non locking manual overide GN VAC non locking manual overide FN VAC non locking manual override (P series only) Solenoid type None (For P series - Operator is fitted to valve) mm (P series only) mm CNOMO coil (P only) mm CNOMO coil (M connection) (P only) Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Weight kg (lbs) Part number /" Solenoid operated (not included) () (). (.) (.) (.). (.8) PSASGN /" VDC Solenoid & cable plug () (). (.) (.) (.). (.9) PSASGNCCN /" Internal air pilot operated () (). (.) (.) (.). (.8) PSAYN /" External air pilot (/8" threaded) () (). (.) (.) (.). (.8) PSAPPN /" Solenoid operated (not included) 8 () (). (.) 88 (.). (.8).8 (.) PSASCN /" VDC mm coil & cable plug 8 () (). (8.9) 88 (.). (.8).9 (.) PSASCNACN /" Internal air pilot operated 8 () (). (.) (.9). (.8).9 (.) PSAYN /" External air pilot (/8 threaded) 8 () (). (.) (.9). (.8).8 (.) PSAPPN Standard part numbers shown in bold. For other models refer to Options chart above.
71 -UK PS / PS Series Technical Information Fluid: Compressed air Max. pressure solenoid operated: bar ( psig) Max. pressure air pilot operated: bar ( psig) Min. operating pressure: bar ( psig) Temperature Max.* solenoid operated: - C to C ( F to F) Temperature Max.* air pilot operated: - C to 8 C (- F to F) Air pilot port: /8" Gauge port: PS - /8" / PS - /" Typical flow with. bar inlet pressure and bar PS dm /s ( scfm) pressure drop: PS 8 dm /s ( scfm) * Air supply must be dry enough to avoid ice formation at temperatures below + C Snap pressure: Full flow when downstream pressure reaches % of the inlet pressure Material Specifications Body: Body cover: Seals: Mounting Brackets Description L-bracket mounting kit Foot bracket mounting kit Aluminum Polyester Nitrile NBR Part number PS PHKAML PHKAMC Flow Charts PSA /" Soft Start Valve Secondary Pressure - (psig) 8 Secondary Pressure - bar Inlet Pressure -. bar (9. psig) 8 Flow - dm /s PSA /" Soft Start Valve Secondary Pressure - (psig) 8 Secondary Pressure - bar. bar 8 psig. bar. bar. psig. bar 8 psig. psig bar. psig 8. bar psig 8 Flow - (scfm) Inlet Pressure -. bar (9. psig) 8. bar. psig. bar 9. psig. bar 9. psig. bar 8 psig. bar. psig. bar 8 psig bar. psig 8. bar psig bar 9. bar psig. psig bar psig 9. bar. psig 8 Flow - dm /s 8 8 Flow - (scfm) Note: For solenoid operators and cable plugs (connectors) see pages to. Dimensions PS - + PS (.) (.) (.) (.) /8" Gauge Port. (.8) 9. (.) /" Gauge Port. (.) Soft Start Function: (.) % (.). (.) Start signal Switching time delay Gradual pressure build up Operating pressure p (=p ) For mounting brackets see page 8. (.9)
72 -UK PT / PT Series Combined Soft Start / Dump Valve Symbol Modular design with /" or /" integral ports (NPT & BSPP) Provides for the safe introduction of pressure The -way, -position function automatically dumps downstream pressure on the loss of pilot signal Adjustable slow start Solenoid or air pilot options High flow & exhaust capability Silencer included Parker Global Series Combined Soft Start / Dump Valves, provide for the safe introduction of pressure to machines or systems. Soft Start / Dump Valves when set, allow the pressure to gradually build to the set point before fully opening to deliver full flow at line pressure. Options: The controlled introduction of pressure can be an important safety factor and prevent damage to tooling when air pressure is introduced at machine or system start up. To maintain these units in the open position a pilot supply to the air pilot operated version or an electrical signal to the solenoid operated version must be maintained. The valve will automatically dump when the holding signal is removed. PTA N Solenoid type only Body size Soft start / dump valve (/") Soft start / dump valve (/") Note: P unit used for both P & P series Bold items are most common. PTA PTA Thread type BSPP NPT 9 Port size Global modular mini (/") Global modular compact (/") Pilot type P External air pilot S Solenoid pilot Actuator interface G mm solenoid (P only) C mm solenoid P Threaded air pilot C A D Solenoid voltage Solenoid / Coil not fitted CN VDC non locking manual overide GN VAC non locking manual overide FN VAC non locking manual override (P series only) Solenoid type None (For P series - Operator is fitted to valve) mm (P series only) mm CNOMO coil (P only) mm CNOMO coil (M connection) (P only) Port size Description Flow dm /s (scfm) Max. bar (psig) Height Width Depth Weight kg (lbs) Part number /" Solenoid operated (not included) () (). (.) (.) (.). (.8) PTASGN /" VDC Solenoid & cable plug () () (.) (.) (.). (.9) PTASGNCCN /" External air pilot operated () (). (.) (.) (.). (.8) PTAPPN /" Solenoid operated (not included) (9) (). (.) 88 (.). (.).8 (.9) PTASCN /" VDC mm coil & cable plug incl. (9) (). (8.9) 88 (.). (.).9 (.) PTASCNACN /" External air pilot operated (9) (). (.) (.9). (.).8 (.9) PTAPPN Includes exhaust silencer. Flow with. bar (9.) psig) inlet and bar (. psig) pressure drop. Standard part numbers shown in bold. For other models refer to Options chart above.
73 -UK PT / PT Series Technical Information Fluid: Max. pressure solenoid operated: Max. pressure air pilot operated: Min. operating pressure: Compressed air bar ( psig) bar ( psig) bar ( psig) Temperature Max.* solenoid operated: - C to C ( F to F) Temperature Max.* air pilot operated: - C to 8 C (- F to F) Air pilot port: /8" Exhaust port: PT - /" / PT - /" Gauge port: PT - /8" / PT - /" Typical flow with. bar inlet pressure and bar PT dm /s ( scfm) pressure drop: PT 8 dm /s ( scfm) * Air supply must be dry enough to avoid ice formation at temperatures below + C Snap pressure: Full flow when downstream pressure reaches % of the inlet pressure Material Specifications Body: Body cover: Seals: Mounting Brackets Description L-bracket mounting kit Foot bracket mounting kit Aluminum Polyester Nitrile NBR Part number PT PHKAML PHKAMC Flow Charts PTA /" Soft Start & Dump Valve Secondary Pressure - (psig) PTA /" Soft Start & Dump Valve Secondary Pressure - (psig) 8 Secondary Pressure - bar 8 Inlet Pressure -. bar (9. psig) 8 Secondary Pressure - bar. bar. psig Flow - dm /s 8 Flow - (scfm) Inlet Pressure -. bar (9. psig) 8. bar 8 psig. bar. psig. bar 8 psig. bar 8 psig. bar. psig. bar 9. psig. bar 9. psig. bar 8 psig. bar. psig bar. psig bar. psig 8. bar psig 8. bar psig bar 9. bar psig. psig 9. bar. psig 8 Flow - dm /s 8 8 Flow - (scfm) bar psig Note: For solenoid operators and cable plugs (connectors) see pages to. Dimensions PT - + PT - + (.8) (.) (.) (.) 8 (.). (.) /8" Gauge Port. (.). (8.9). (.8) 9. (.) /" Gauge Port Soft Start Function: (.) (.) (.8) % (.) (.9). (.) (.) Start signal Switching time delay Gradual pressure build up Operating pressure p (=p ) For mounting brackets see page 8. (.9) (.)
74 -UK Solenoid Operators Solenoid operator - CNOMO Order key P F P N B Operator Type Pressure / Temp Manual / Override CNOMO x Plastic N bar / - O C to + O C B Non locking - monostable - Flush - Brass Technical data - Solenoid operators, coil combinations NC Normal Operator NC Normal Operator with x with x standard coil standard coil Working pressure to bar to bar Ambient temperature - C to C () - C to C () Orifice./.mm./.mm Flow Qn.8 dm /s.8 dm /s Power (DC).W.8W Power (AC).9VA 8.VA Voltage tolerance +/- % +/- % Duty cycle % % Insulation class F F Electric connection Form A Industrial B Protection IP IP Shock & Vibration g g Approval Working media UL/CSA All neutral media such as compressed air and inert gases. () limited to C if use with % duty cycle Transients Interrupting the current through the solenoid coil produces momentary voltage peaks which, under unfavourable conditions, can amount to several hundred times the rated operating voltage. Normally, these transients do not cause problems, but to achieve the maximum life of relays in the circuit (and particularly of transistors, thyristors and integrated circuits) it is desirable to provide protection by means of voltage-dependent resistors (varistors). All connectors/cable plugs EN-8 with LED s include this type of circuit protection. Materials Pilot Valve Body: Armature tube: Plunger & core: Seals: Screws: Coil Encapsualtion material: Polyamide Brass Corrosion resistant Cr-Ni steel FKM (Viton ) Stainless steel Thermoplastic as standard Duroplast for M connection Solenoid coils with Din A or Industrial B connection Voltage mm x mm mm x mm Order code DIN A Weight (Kg) Order code Industrial B Weight (Kg) Standard Standard Direct current V DC PFCA. PFCB.9 V DC PFCA9. PFCB9.9 8V DC PFCA*. PFCB.9 Alternative current V /Hz PFCA. PFCB.9 V /Hz PFCA. PFCB.9 8V /Hz PFCA9 #. V Hz, V Hz PFCA*. PFCB.9 V Hz, V Hz PFCA. PFCB.9 * PFCA is compatible with V AC and 8 V DC # PFCA9 is V DC.8W or 8 V Hz 9.9 VA Solenoid coils with M connection Voltage Order code Form A W (Kg) Order code Form B W (Kg) x x Direct current V DC PFC9. PFC9. Spare Solenoid Operators Solenoid pilot operator CNOMO NC Description Order code Weight (Kg) Non-lock manual override Standard duty PFPNB. Note. Solenoid pilot operators are fitted to the Global range. Order the above part numbers for spares. The operators are supplied with mounting screws and interface O rings. Coils and connectors must be ordered separately. Spare Solenoid Nuts Valves requiring captured exhaust should be fitted with plastic knurled nut Order code PFNP Valves with vented exhaust are fitted with diffuser plastic nut Order code PFND
75 -UK Solenoid Coils & Cable Plugs Solenoid Connectors / Cable Plugs EN-8 With large headed screw suitable for mounting in inaccessible or recess position With standard screw With cable Description Order code Order code Order code mm Form C mm Form B mm Form A ISO Industrial ISO Standard IP P8C-C V DC P8C-CC LED and protection IP V AC P8C-CE LED and protection IP Standard IP P8C-D EVV EV9V without flying lead With LED and protection P8C-DC EVV- EV9V- V AC/DC With LED and protection P8C-DE EVV- EV9V- V AC With LED and protection EVV- EV9V- V AC Standard with m cable IP P8L-C Standard with m cable IP P8L-C V AC/DC, m cable P8L-CC LED and protection IP V AC/DC, m cable P8L-CC EVV-L EV9V-L LED and protection IP V AC/DC, m cable P8L-CAC LED and protection IP V AC/DC, m cable P8L-CE LED and protection IP V AC/DC, m cable P8L-CE EVV-L EV9V-L LED and protection IP V AC, m cable EVV-L EV9V-L LED and protection IP Solenoid Coil & Cable Plug Dimensions (mm) PF - CNOMO - x mm P8C-C P8C-D P8L-C P8L-C EVV P8C-DC P8C-DE P8C-CC P8C-CE EVV- EVV- EVV- P8L-CC P8L-CC P8L-CAC P8L-CE P8L-CE EVV-L EVV-L EVV-L Form C Cable plugs Form C Cable plugs Form B Cable plugs Form A Cable plugs P8C-C P8C-CC P8C-CE P8C-D P8C-DC P8C-DE P8L-C P8LC P8L-CC P8L-CC P8L-CAC P8L-CE P8L-CE EVV,8 M EV9V 8,, 8 Ø,,,
76 -UK Machine Directive - EN ISO 89- Global combined soft start / dump valves to meet Catergory Safetey Standard ISO89- for Catergory, compliant with performance level. (contact the division for details). This product is designed to be used as a component within a system. The single unit alone cannot be considered as a Catergory safetey product. Sensor is energised in the Dump / Exhaust position. Note: For other Technical Data, see pages - Remote operated dump valve & Combined soft start dump valve Port size Description Order code Note / Solenoid operated (not included) PDASC Product is supplied / tested and fitted / Solenoid operated (not included) PTASC with electronic sensor P8S-GPMHX For thread type: NPT 9 (.9) (.) (.). (.) (.) Ordering data /" Gauge Port Electronic sensors, - V DC PNP type, normally open :, m PUR-cable and M screw male connector. (.). (.8) (.) (8.) P8S-GPMHX M V DC Signal + V DC Brown (.9) Black Blue. (.) For solenoid operators and cable plugs (connectors) see pages - (.9)
77 -UK Global Products Fitted with Pressure Sensor Additional methods of pressure monitoring, is to fit a MPS Pressure Sensor in the Global product gauge port. See page 8-8 for details. A reducer Male/Female fitting can be used for P series and Manifold accessories. Reducer, Male/Female BSPP and Metric Thread C C E F L Weight (Kg) Order code G/ G/ G/8 G/ G/... 8 G/ G/... 8 G/ G/ G/... 8 With integrated O-ring seal
78 -UK PT Series Redundant Safety Exhaust Valve Symbol Proven control reliable technology with integrated soft start Soft start application of air to the system when energized; can be adjusted for slower or faster buildup of system pressure Rapid exhaust of downstream air when de-energized to remove stored energy and allow safe access PT Schematic Memory, monitoring, and air flow control functions are integrated into two identical valve elements. Valves lock-out if asynchronous movement of valve elements occurs during actuation or de-actuation, resulting in a residual outlet pressure of less than % of supply. Exh. Pressure Switch Reset can only be accomplished by the integrated electrical (solenoid) reset. Cannot be reset by removing and re-applying supply pressure. Basic / normally closed valve function: Dirt tolerant, wear compensating poppet design for quick response and high flow capacity. LED indicators of main solenoid operation, reset solenoid operation, and status indicator condition. Optional transducer for monitoring of downstream pressure in the system. Dual exhaust silencers included. Not for use with clutch / brake applications. Exh. Exh. Reset port For use in conjunction with a safety relay or safety PLC. Options: PTA R G CN Body size Standard PT Port size /" Operator mm Solenoid G Solenoid Dual M connector without transducer F Voltage VDC with manual override CN Thread type BSPP NPT 9 Type Solenoid pilot + gauge R Mounting Cat w/bracket Triple M connector with transducer G Port size Cv Inlet Outlet Transducer to to Height Width Depth Weight kg (lb) Part number* / / w/o transducer (.8). (.). (8). (.) PTARGFCN / / w/ transducer (.8). (.). (8). (.) PTARGGCN * BSPP port threads. For NPT threads, replace in the part number with a 9. 8
79 SOL. SOL. RESET STATUS SOL -UK PD / PD Series Technical Information Pilot Solenoids: According to VDE 8 Enclosure rating: According to DIN IP Connector socket: According to DIN Form A Three solenoids, rated for continuous duty Standard voltages: VDC Power consumption (each solenoid): for primary and reset solenoids:. Watts on DC Enclosure rating: IP, IEC 9 Electrical connection: M, -pin Ambient temperature: F to F (- C to C) Media temperature: F to F ( C to 8 C) Flow media: Compressed Air, Filtered to Minimum Micron Inlet pressure: to PSIG ( to bar) Pressure switch rating (Status indicator): Amps at Volts DC. Monitoring: Dynamically, cyclically, internally during each actuating and de-actuating movement. Monitoring function has memory and requires an overt act to reset unit after lockout. Mounting orientation: Vertically with pilot solenoids on top Port threads: / NPT, / BSPP Control reliable: Category (Cat ); performance Level e (PLe) in accordance with Machine directive - EN ISO 89- (Certification pending) Repair and Service Kits Description Part number Black grill 8C- Body connector PKACB Cables M, -pin female to flying lead cable, TPE; m (. ft)...rkc.t-/s8 M, -pin male to flying lead cable, TPE; m (. ft)...rsc.t-/s8 Port block kit / NPT...PKA9CP / NPT...PKA9CP / BSPP...PKACP / BSPP...PKACP Pressure switch A- Pressure transducer (Optional) H- T-bracket w/ body connector PKAMT T-bracket (Fits to body connector or port block) PKAMB Silencer(s) /" A Solenoid (Main & reset) B9- Square flush mounting gauge kit, - psig KSCR Valve Wiring -Pin A Code -Pin A Code -Pin A Code Female Connector Female Connector Male Connector (Digital Pressure Transducer (Feedback) (Control Signal) Wiring (optional)) GRAY GRAY Power Input (Equip Ground) Reset BROWN WHITE WHITE BROWN Input Digital (+ Volts DC) (N.O. Status (Sol ) (+ Volts DC) Power + Output Signal Contact) BLACK BLUE (N.C. Status (Common) Contact) BLUE BLACK (Common) (Sol ) Analog Digital Output Signal Output Signal Dimensions %. (.) Control Signal Feedback Pressure Transducer (Optional) Manual Reset - + (+) Increase Time (-) Decrease Time LED Status Lights % % Start signal Switching time delay Gradual pressure build up Operating pressure p (=p ).8 (.8) Inlet Outlet Angle Mounting Bracket 9. (.). (.). (.). (.) Adjustable Soft Start. (.8) 9. (.) (.) (.). (.). (.8). (.) 8X R.. (.) 98. (.8) R. 9. (.). (.) Note: Mounting bracket and installation screws included and required to install unit in the system. 9
80 -UK PT Series Valve de-actuated (ready-to-run): The flow of inlet air pressure to the inlet chamber of the main valve internals is restricted by a fixed orifice and an adjustable flow control as well as an air piloted -way normally closed poppet valve. The flow of inlet air pressure into the crossover passages is restricted by the size of the passage between the stem and the valve body opening. Flow is sufficient to quickly pressurize pilot supply / timing chambers and. The inlet poppets prevent air flow from crossover passages into the outlet chamber. Air pressure acting on the inlet poppets and return pistons securely hold the valve elements in the closed position. (Reset adapter omitted for clarity.) ADJUSTING NEEDLE EXHAUST OUTLET The green Status LED will be illuminated indicating the valve is operational. INLET SOL. SOL. RESET SOL STATUS Valve actuated: Energizing the pilot valves simultaneously applies pressure to both pistons, forcing the internal parts to move to their actuated (open) position, where inlet air flow to crossover passages is fully open, inlet poppets are fully open and exhaust poppets are fully closed. The outlet is then pressurized at a rate allowed by the fixed orifice and the adjusted flow control. Once the air pressure in the outlet chamber reaches approximately % of inlet pressure, the air piloted -way normally closed poppet valve opens fully and the pressure in the inlet, crossovers, outlet, and timing chambers are quickly equalized. The adjustable flow control will control the time it takes for the outlet air pressure to reach approximately % of inlet pressure. De-energizing the pilots quickly causes the valve elements to return to the ready-to-run position. Solenoid, Solenoid and the green Status LED s will be illuminated indicating the valve is operating properly. ADJUSTING NEEDLE EXHAUST OUTLET INLET SOL. SOL. RESET SOL STATUS Soft start function: % % % Start signal Switching time delay Gradual pressure build up Operating pressure p (=p ) 8
81 -UK PT Series Valve fault and lock-out: Whenever the valve elements operate in a sufficiently asynchronous manner, either on actuation or de-actuation, the valve will move to a locked-out position. In the locked-out position, one crossover and its related timing chamber will be exhausted, and the other crossover and its related timing chamber will be fully pressurized. The valve element (side ) that is partially actuated has pilot air available to fully actuate it, but no air pressure on the return piston to fully de-actuate the valve element. Air pressure in the crossover acts on the differential of side stem diameters creating a latching force. Side is in a fully closed position, and has no pilot air available to actuate, but has full pressure on the inlet poppet and return piston to hold the element in the fully closed position. Inlet air flow on side into its crossover is restricted, and flows through the open inlet poppet on side, through the outlet into the exhaust port, and from the exhaust port to atmosphere. Residual pressure in the outlet is less than % of inlet pressure. The return springs are limited in travel, and can only return the valve elements to the intermediate (locked-out) position. Sufficient air pressure acting on the return pistons is needed to return the valve elements to a fully closed position. The red Status LED will be illuminated indicating the valve in fault and lock-out must be reset ADJUSTING NEEDLE EXHAUST OUTLET INLET SOL. SOL. RESET SOL STATUS Valve reset (electrical or manual): The reset procedure is as follows: Remove the electrical signals to the main coils Ensure there is air supplied to the valve Energize the reset solenoid for a minimum of ms Allow a ms delay after de-energizing the reset solenoid and re-energizing the main solenoids The valve will remain in the locked-out position, even if the inlet air supply is removed and re-applied. A remote reset signal must be applied to reset the valve. A momentary, remote electrical signal must be applied to the reset solenoid to apply pressure to the reset pistons in the valve. Actuation of the reset piston physically pushes the main valve elements to their closed position. Inlet air fully pressurizes the crossovers and holds the inlet poppets on seat. Actuation of the reset piston opens the reset poppet, thereby, immediately exhausting pilot supply air, thus, preventing valve operation during reset (Reset adapter added to illustration.). De-actuation of reset pistons causes the reset poppets to close and pilot supply to fully pressurize. Reset air pressure is applied by a / normally closed solenoid, or a manual push button mounted on the reset adapter in the top valve cover. The green Status LED will be illuminated once the valve is reset. ADJUSTING NEEDLE Control Signal Feedback EXHAUST OUTLET INLET Pressure Transducer (Optional) Manual Reset Inlet SOL. SOL. RESET SOL STATUS SOL. SOL. RESET SOL STATUS 8
82 -UK P, P, P Series Ball Valve / Lockout Valve Symbol Features The Ball / Lockout Valve shuts off downstream line pressure in the closed position with a 9 turn of the handle. In the closed position, inlet air pressure is blocked and downstream / system air is exhausted through a threaded port. To prevent unauthorized adjustment, the padlock slide may be assembled on either side. It is recommended that this slide is installed after final system assembly. Note: This padlock slide is a permanent assembly and may not be removed later, any unauthorized tampering will void any warranty claims. The valve can only be locked in the closed position. Ordering Information Model type Port size Exhaust port For thread type: NPT 9 Thread type Flow dm /s (scfm) Modular ball valve flow from left to right P /" /" BSPP (.) PVBLBNN P /8" /" BSPP 9 (9.) PVBLBNN /" /" BSPP (8.) PVBLBNN P /" /" BSPP (.) PVBLBNN /" /" BSPP (8) PVBLBNN Specifications Operating temperature - C to 8 C (- F to F) Max. supply pressure bar ( psig) Port size BSPP / NPT /, /8, /, / Weight P:. kg (. lbs) P:. kg (.9 lbs) P:. kg (. lbs) Material Specifications Body Aluminum Seals PTFE Ball P Stainless Steel P / P Stainless Steel Dimensions P P P (.) (.8) (.8). (.) (.) (.) (.8) (.8) (.). (.) (.8) (.8) (.9) (.8) 8. (.). (.8) 88 (.) 98. (.8). (.8). (.). (.) / Thread Port / Thread Port / Thread Port 8
83 -UK P, P, P Series Manifold Blocks Features Available in /, / & / threaded inlet / outlet ports Two additional top and bottom auxiliary ports standard Can be mounted anywhere in the FRL system Manifold Blocks Model In / Out Auxiliary Auxilliary Thread Order Code Type Port Port Port Type Size Size Size Top Bottom P / / / BSPP PMAN P / / / BSPP PMAN P / / / BSPP PMAN For thread type: BSPP NPT 9 Branch Manifold Dimensions - P. (.8). (.) Top port / Branch Manifold P / / / BSPP PMDN P / / / BSPP PMDN. (.8) (.) (.) Materials of Construction Body Specifications Max Operating Temperature Aluminium. C ( F) 8 (.8) 9 (.) (.) Bottom Port / Max Supply Pressure. bar ( psi) Weight P:.9 kg (. lbs) P:. kg (. lbs) PMD:. kg (. lbs) P:. kg (. lbs) Outlet Port /. (.8). (.) Manifold Block - Dimensions P P Inlet port / P Top port / Outlet port / Inlet port / Top port / Outlet port / Top and bottom aux. ports / Flow (.9) (.8) (.).9 (.9).8 (.88) (.8). (.). (.). (.). (.88). (.) IN (.) 9 (.) OUT (.8).9 (.9).8 (.88).9 (.9).8 (.88) Bottom port / Bottom port / 8
84 -UK Pressure Sensors Pressure Sensors MPS-, -Colour Panel Mount Sensor output: PNP Open collector Transistor output, VDC, ma with Analog output, to ma Output response time less than. milliseconds RoHS Air and non-corrosive gases Sensor face includes icons to show sensor programming status Red Green Display Programming options Outputs change N.O. / N.C. Units of measure change Hysteresis mode Window comparator mode Auto teach mode Output response time Lockout option Password lockout Max. value display Min. value display Zero reset Red / Green LED display options Error output mode MPS- Sensor Only Ordering Numbers Order code Pressure range Electrical output Electrical connection /8 NPSF male /8 BSPP male - inhg () PNP with () -ma M8, Pin MPS-VN-PCI MPS-VG-PCI - PSI () PNP with () -ma M8, Pin MPS-PN-PCI MPS-PG-PCI MPS- Accessories Description Order code M8, -pin, meter cable CB-M8-P-M-PUR M8, -pin, meter cable CB-M8-P-M-PUR Internal circuit for open collector and analog output wiring Sensor pin out with analog output PNP Output (Analog (-ma) +V (Brown) Pin # Brown: VDC Switch main circuit Out (Black) Analog (White) (-ma) V (Blue) Load Max. 8mA + - DC ~V ± % White: to ma Blue: VDC Black: PNP Open Collector Output 8
85 -UK Pressure Sensors Specifications Vacuum (V) Positive (P) Pressure range -. to kpa (-. to PSI) -. to Mpa ( to PSI) Proof pressure. Mpa (PSI). Mpa (8 PSI) Display resolution, Units of measure Media Pressure port Operating temperature Storage temperature Humidity Electrical connection Power supply Display Display refresh., kpa., kgf/cm., bar., PSI., inhg, mmhg Air & non-corrosive gases, kpa., kgf/cm²., bar., PSI - - (N) /8" NPT male, (G) /8 BSPP male both with M female port to F ( to C) - to F (- to C) to 8% RH (no condensation) (C) -pin, M8 connector on mm lead wire to VDC ±%, Ripple (P-P) % or less + / digit, color, -segment RED / GREEN LED Timing update :. ~ sec. (Factory Set Unit:. sec.) Switch output Output signal, PNP, Normally open or closed, LED indicator, ma max. output load Output modes Hysteresis or Window Comparator Response time.ms (chattering-proof function: ms, ms, ms, ms and ms selections) Repeatability ±.% of F.S. ± digit Output current Output current to ma; Linearity ±.% of F.S.; Maximum load impedance Ω at power supply of V; Ω at power supply of V; Minimum load impedance Ω Thermal error to F ( to C) C ( C) + % of F.S. or less at range of to F ( to C) General protection IP, CE marked, EMC-EN--: Current consumption ma (with no load) Vibration resistance to Hz, Double amplitude.mm, XYZ, hrs. Shock resistance 98 m/s² (about G), times/each directions X, Y, Z Noise Resistance Vp-pV, ms,.μs noise simulator Material Housing: ABS (gray), Pressure port: Zinc die-cast, Diaphragm: Silicon Mass. oz. (g) with M8 connector Dimensions /8" Male. (.). ().8 () mmhg inhg PSI BAR Kgf kpa Key Lock Indicator Output Indicator Button ( ) Setting Button MAX WIN N.C. AUTO OUT MAX HYS N.O. MAN ( ) Button Pressure Unit Display Section Colors, Main Display Setting Mode Display Section M Female N: NPT /8, with M female G: G/8, with M female Hex Flat 8
86 -UK P Series Accessories - P Series C-Bracket (Fits to filter and lubricator body) PKAMW. (.) (.) 8 (.8). (.) (.9) (.) (.). (.) 9. Dia (.) (.8) (.) T-Bracket w/ Body Connector (O-ring not shown) PKAMT (.8) (.9) 9 (.) (.9). (.) (.) Body Connector (O-ring not shown) PKACB (.9) Port Block Kit (O-ring not shown) /8 NPT... PKA9CP / NPT... PKA9CP /8 NPT... PKA9CP /8 BSPP... PKACP / BSPP... PKACP /8 BSPP... PKACP (.) (.9) Port Block Kit w/ T-Bracket (O-ring not shown) /8 NPT...PKA9CN / NPT...PKA9CN /8 NPT...PKA9CN /8 BSPP...PKACN / BSPP...PKACN /8 BSPP...PKACN Angle Bracket (Fits to regulator and filter/regulator body) PKBMR PKBMS - with Metal Nut (.98) (. ) (.) (.) 8 (.) (.) (.). (.) Dia. 8
87 -UK P Series Accessories - P Series T-Bracket w/ Body Connector PKAMT Body Connector PKACB 8.9 (.) 8.9 (.) O-Ring O-Ring. Dia. (.8) O-Ring. Dia. (.8) Port Block Kit / NPT... PKA9CP /8 NPT... PKA9CP / NPT... PKA9CP / NPT... PKA9CP / BSPP... PKACP /8 BSPP... PKACP / BSPP... PKACP / BSPP... PKACP Angle Bracket (Fits to regulator and filter/regulator bonnet) PKBMR PKBMS - with Metal Nut. (.) 9. (.) 8. (.) 9. (.). (.). (.8) 8. Dia (.9) (.8) 9.9 (.) (.) L-Bracket (Fits to filter and lubricator body) PKAML (.) 9. (.8) 8 (.) (.88) (.8) 9. (.) (.) (.). (.8) Dia (.) T-Bracket (fits to body connector or port block) PKAMB 9 (.). (.) (.) (.9 ). (.9) (Typ.). (.8) 8
88 -UK P Series Accessories - P Series T-Bracket w/ Body Connector PKAMT Body Connector PKACB 8.9 (.) 8.9 (.) O-Ring O-Ring. Dia. (.8) O-Ring. Dia. (.8) Port Block Kit / NPT... PKA9CP /8 NPT... PKA9CP / NPT... PKA9CP / NPT... PKA9CP / BSPP... PKACP /8 BSPP... PKACP / BSPP... PKACP / BSPP... PKACP Angle Bracket (Fits to regulator and filter/regulator bonnet) PKAMR (.) (.) (98) (.99) 8 (.89) (.) Dia (.) (.) 8. (.) 9 (.9) L-Bracket (Fits to filter and lubricator body) T-Bracket (fits to body connector or port block) PKAML PKAMB (.) 9. (.8) 8 (.) (.) 8 (.88). (.8). Dia (.) 9 (.). (.9) (Typ.) 8 8 (.) (.) 8 (.9). (.) (.). (.8) (.9 ) 88
89 -UK Kits & Accessories Series Description Part number P P P Panel Mount Nut (Plastic) PKAMP PKAMP PKAMP P P P Panel Mount Nut (Aluminum) PKAMM PKAMM PKAMM P P P µ Element Kit PKAESE PKAESE PKAESE P P P µ Element Kit PKAES9 PKAES9 PKAES9 P P P.µ Element Kit PKAESC PKAESC PKAESC P P P Adsorber Element Kit PKAESA PKAESA PKAESA P / P Auto Drain Kit PKADA P P / P Differential Pressure Indicator Kit PKBRQ PKARQ P / P / P Drip Control Assembly Kit PKAPH P P / P Fill Plug Kit PKBRQ PKAPL P P P Lubricator - Plastic Bowl w/ Bowl Guard No Drain PKBBGN PKBBGN PKABGN 89
90 -UK Kits & Accessories Series Description Part number P P P Lubricator - Metal Bowl w/o Sight Gauge No Drain PKBBMN PKBBMN PKABMN P P Lubricator - Metal Bowl w/ Sight Gauge No Drain PKBBSN PKABSN P P P Metal Bowl w/o Sight Gauge & Manual Drain PKBBMM PKBBMM PKABMM P Metal Bowl w/o Sight Gauge & Pulse Drain PKBBMB P P Metal Bowl w/o Sight Gauge & Auto Drain PKBBMA PKABMA P P Metal Bowl w/ Sight Gauge & Manual Drain PKBBSM PKABSM P P Metal Bowl w/ Sight Gauge & Auto Drain PKBBSA PKABSA P P P Plastic Bowl w/ Bowl Guard & Manual Drain PKBBGM PKBBGM PKABGM P Plastic Bowl w/ Bowl Guard & Pulse Drain PKBBGB P P Plastic Bowl w/ Bowl Guard & Auto Drain PKBBGA PKABGA 9
91 -UK Kits & Accessories Series Description Connection Part number P Square Flush Mounting Gauge Kit - bar - bar - psig - psig KSCRB KSCRB KSCR KSCR (.9) (.) (.) P Square Mounting Gauge with Adapter Kit - bar - bar - psig - psig PG-PR PG-PR PG-PR9 PG-PR9 P " Round Gauge - psig / -. bar - psig / - bar /8" /8" KN8 KN8 (.) 9 (.) (.) P mm Round Gauge - psig / - bar - psig / -. bar - psig / - bar /8" /8" /8" KN8 KN8 KN8 (.) (.98) (.) P / P mm Round Gauge - psig / - bar - psig / -. bar - psig / - bar - psig / - bar /" /" /" /" KN KN KN KN 8 (.) (.9) (.9) P P / P Body Connector O-ring (Replacement kit) (Pack of ) PKACY PKACY P P Tamperproof Knob Kit PKBAT PKBAT P P Tamperproof Lockable Kit PKBAL PKBAL 9
92 -UK Pressure Switches Plugs to DIN EN -8, Form A, ISO Standard version Version with LEDs Plugs to DIN EN -8, Form A, ISO Description Type Order code Standard version GSD-DS KL9 Version with LEDs V GSD-DSLV KL Version with LEDs V GSD-DSLV KL 9
93 -UK Pressure Switches Pressure Switches G/8, G/ Break contact Make contact Characteristics Safety pressure relief Pmax bar Port size G/8, G/ Medium and ambient Tmax + O C temperature range Switch back difference Max. - % Voltage Max. 8 V Current. A Degree of protection IP Switching frequency Max. s/min Material Housing Diaphragm Switching function Make contact Break contact Passivated steel Buna N Closes the circuit when the set pressure is reached Interrupts the circuit when the set pressure is reached Dimensions and order instructions Order instructions Port Function Setting Order Type size range code A (bar) PR /.- NC ST / 8 G/ Break contact.- KL9 PR /.- NO ST / 8 G/ Make contact.- KL PR / - NC ST /8 8 G/8 Break contact - KL PR / - NC ST / 8 G/ Break contact - KL PR / - NO ST /8 8 G/8 Make contact - KL8 PR / - NO ST / 8 G/ Make contact - KL Order instructions Port Function Setting Order Type size range code A (bar) PR /.- NO SR / 8 G/ Make contact.- KL PR /.- NC SR / 8 G/ Break contact.- KL PR /.- NO SR / 8 G/ Make contact.- KL PR / - NC SR /8 8 G/8 Break contact - KL PR / - NC SR / 8 G/ Break contact - KL PR / - NO SR /8 8 G/8 Make contact - KL PR / - NO SR / 8 G/ Make contact - KL Plug can be turned 9 O Protective cap can be turned x O View A without plug View A without protective cap Dimensions in mm 9
Parker Global Air Preparation System
Parker Global System Parker Global System A complete air preparation system 7 Parker Global System Parker Global Air Preparation System Global. Economical. Modular. Performance you need, wherever you need
More informationParker Global Air Preparation System. A complete air preparation system
Parker Global Air Preparation System A complete air preparation system Catalogue 0750-UK September 2010 DECLARATIO OF COMPLIACE (ROHS) European Directive 2002/95/EC - RoHS (Restriction of use of certain
More informationParker Global Air Preparation System
Parker Global Air Preparation System Global. Economical. Modular. Performance you need, wherever you need it. The comprehensive Global Air Preparation System is available in three body sizes with either
More informationP31EB 2 E N P. Element. 5µ Element E. Poly bowl with bowl guard Metal bowl without sight gauge. Height mm (inches) Max. bar (psig)
Series ini Filter / Regulator - Symbols Integral /" ports (NT & BS) High efficiency micron element as standard Excellent water removal efficiency Robust but lightweight aluminum construction ositive bayonet
More informationAir Preparation Products. Air Preparation Products. Section E. Air Preparation Products. Catalog PDN1000-3US Parker Pneumatic
Catalog PDN1-3US Section 1 Catalog PDN1-3US Pictorial Index - www.parker.com/pneu/airprep Pictorial Index Global FRL s 3 Port size: 1/4 through 3/4 inch Maximum supply pressure: 3 PSIG Operating temperature:
More informationP31F A 9 2 E G M N. Global Modular Particulate Filters. Air Preparation Products. Global Modular Particulate Filters. Operating information
Catalog PDN-US Global Modular Particulate Filters Integral /", /", /", or /" ports (NPT, BSPP & BSPT) High efficiency micron element as standard xcellent water removal efficiency Robust but lightweight
More informationThe P3Y Modular FRL System
For the most demanding hi-flow industrial applications The P3Y Modular FRL System The P3Y system allows units to be connected together, without the use of pipe connectors, saving space; providing constant
More information74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.
NCA-33 January 1998 Supersedes November 199 EXCELON Series System Features...2 EXCELON Series Product Features... Filters F72G General Purpose Filters... F73G General Purpose Filters...8 F7G General Purpose
More informationFluid Power Products. Kaman Fluid Power is an authorized distributor of Parker Motion Products
Fluid Power Products Kaman Fluid Power is an authorized distributor of Parker Motion Products B.W. Rogers Calkins Fluid Power Catching FluidPower INRUMEC Northwest Hose & Fittings Western Fluid Components
More informationAIR PREPARATION PRODUCTS. Table of Contents
AIR PREPARATION PRODUCTS Table of Contents Page Air Filters................................................. 5-7 Oil Removal Filters......................................... 8-9 Regulators..............................................
More informationP3Y Series Air preparation system. 3/4 & 1 Body ported
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P3Y Series Air preparation system 3/4 & 1 Body ported Catalogue no.
More informationFilters, regulators, and lubricators
Filters, regulators, and lubricators 28 filters 3/8", 1/2", and 3/4" Ports Technical data Polycarbonate bowl Polycarbonate bowl guard Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain
More informationARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS
ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS For more than years, Ingersoll Rand ARO has been an industry leader in the design and ARO-Flo Series manufacture of compressors, pneumatic tools, and
More informationAir Preparation Products
Air Preparation Products Series Series Filter Regulator Lubricator (FRL) www.asco.com Table of Contents / Series Product Overview 2 Particulate Filter 4 Coalescing Filter 8 Adsorber Activated Carbon 8
More informationAir Preparation Products. Truck Hydraulics Center Section B. Air Preparation Products. Air Preparation Products. Catalog 0650-E
Section 1 R34 Low Temperature Regulators General Industrial Diaphragm operated for fast operation Large Diaphragm to valve area ratio for precise regulation and high flow capacity alanced valve design
More informationBL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units
BL84 - Excelon Plus Modular System > Port Size 3/8" to 3/4" (PTF/ISO G) > Quickclamp connection system offers full modularity > Shut off valve & Filter/regulator with tamper resistant feature > Metal bowl
More information3000 Series filters 3/4" and 1" Ports
38 filters 3/4" and 1" Ports Technical data Metal bowl Metal bowl sight glass Filter body Manual drain Auto drain Standard filter Coalescing filter Seals Filter baffle Aluminum Nylon Aluminum Brass + nitrile
More informationAir Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off
Air Line Modulars Each component is engineered to connect easily without the use of inserts and special tools. Standard buttonhead screws are used to join components, combined with the new modular design
More informationAir Preparation Products. For Low Temperature Service. Parker Hannifin Corporation Pneumatic Division Richland, Michigan
Air Preparation Products For Low Temperature Service Catalog -E Miniature R Series R Regulators Miniature Miniature Regulators /8", /" Basic /8" Body R-C Non- R-MC Features Diaphragm operated for fast
More informationAir Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications
Air Preparation Products Series Filter Regulator (FR) for Process Industry Applications www.asconumatics.eu Table of Contents Series Particulate Filter/Regulator 2 Particulate Filter 5 Regulator 8 Kits
More informationDrain Type Semi-Automatic
INLINE FILTERS Features Pipe or Bracket Mounted Point of Use Filters Quick Release Bayonet Bowl Connection Easy Change Filter Elements Transparent Filter Bowl For Element Inspection Semi Automatic (pull
More informationZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES
INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS Compressed Air Filters 15-1600 scfm FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES Z E K S Z T F C O M P R E S S E D A I R F I
More informationBL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units
BL84 - Excelon Plus Modular System > Port size: 3/8... 3/4 (ISO G/PTF) > Unique Quikclamp connection system offers full modularity > 40 micron particle and high efficiency water removal (> 98%) > Shut
More informationInstallation Components AirCare Air Preparation Systems
Care Preparation Systems Modular Line Filters 602104 602106 602108 * Transparent 602109 nylon liquid level indicator -18 lens. to 79 C Body Bowl Material icle Zinc Aluminum Zinc* Aluminum* Sintered Polypropylene
More informationF200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades
F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction
More informationF200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades
F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction
More information50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an
FRL Products and Accessories High Flow FRL Series 50 Series Filters 44 50 Series Regulators 45 50 Series Pilot Operated Regulators 46 50 Series Lubricators 48 50 Series Filter/Regulator/Lubricator Combinations
More informationColorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US
Colorflow and Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Fully guided poppets are used on Colorflow valves rather than the less durable ball-check type construction.
More informationVALVES. Wilkerson. Filters, Regulators & Lubricators. dixonvalve.com Customer Service:
FACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURI VALVES Wilkerson Filters, Regulators & Lubricators dixonvalve.com Customer Service: 877.963.4966 Filters
More informationStainless Steel FRLs
Stainless steel FRLs Stainless Steel FRLs Units 205 Stainless steel FRLs - PF504 Series - 1/4 Inch Ports PF504 Filter Miniature Features Stainless steel construction handles most corrosive environments
More informationF64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6
Olympian Plus eneral Purpose Filter F, FE eneral purpose filters Olympian Plus plug in system Effective liquid removal and positive solid particle filtration Large filter element area provides minimum
More informationFilters, Gauges, Regulators
Filters, s, Regulators SCFM = Cubic ft/min at Ambient Condition s Sold Separately s...1/4" Flow SCFM...21 s...1/4" Flow SCFM...15 Filters - Construction Mini 1/4" 3000 Regulators Without Mini 1/4" 3100
More informationModel Model 815
Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............
More informationFlow Control Valves Check Valves Gauge Control Valves. Colorflow Valves
Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on
More information12 Series Miniature FRLs
12 Miniature FRLs www.numatics.com Table of Contents 12 Features and Benefits 3 Particulate Filter 4 Coalescing Filter 5 Regulator 6 Particulate Filter/Regulator 7 Coalescing Filter/Regulator 8 Lubricator
More informationMOUNTING BRACKETS. Dimensional Drawing - Mounting Options
/ MOUNTING BRACKETS Dimensions: mm Dimensional Drawing - Mounting Options Series Side Mounting Brackets Kit: PAT503860001 Series Side Mounting Brackets Kit: PAT503860002 E G F C D ØH B A Series A B C D
More informationModuflex FRLs. Moduflex40 P3H Series 1/8 and 1/4 ported. Moduflex60 P3K Series 3/8 and 1/2 ported. Moduflex80 P3M Series 1/2, 3/4 and 1 ported
Moduflex FRLs Moduflex40 P3H Series 1/8 and 1/4 ported Moduflex60 P3K Series 3/8 and 1/2 ported Moduflex80 P3M Series 1/2, 3/4 and 1 ported Catalogue no. PDE2501TCUK-ca Edition: June 2007 Table of Contents
More informationModuflex FRLs. Moduflex40 P3H Series 1/8 and 1/4 ported. Moduflex60 P3K Series 3/8 and 1/2 ported. Moduflex80 P3M Series 1/2, 3/4 and 1 ported
Moduflex FRLs Moduflex40 P3H Series 1/8 and 1/4 ported Moduflex60 P3K Series 3/8 and 1/2 ported Moduflex80 P3M Series 1/2, 3/4 and 1 ported Catalogue no. PDE2501TCUK-ca Edition: June 2006 Table of Contents
More informationInstallation Components AirCare Air Preparation Systems
Modular Line Filters 602104 602106 602108 602109 250 psig / 17 bar Body Material icle Zinc Zinc* * Sintered Polypropylene 40µ 602104 Drain Type Port PTF ¹ ₄ 602106 Manual ³ ₈ A B C Dia. 5.27 / 1.34 0.75
More informationCORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT
CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT Most SHAVO units are available in port sizes from 1/8 to 2 and there is a wide choice of filter elements and regulating and relief spring ranges
More informationManufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS
Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS New Product Introduction 400 PSI High Pressure Regulator Ports: 1/8, 1/4, 3/8 Problem: Most spring activated
More informationAir Preparation Products. Air Preparation Products. Section E. Air Preparation Products. Catalog PDN1000-3US Parker Pneumatic
Section 1 Catalog PDN1000-3US (Revised 05-15-14) Pictorial Index - www.parker.com/pneu/airprep Pictorial Index Global FRL s 3 size: 1/4 through 3/4 inch Maximum supply pressure: 300 PSIG Operating temperature:
More informationDimensional Drawing - Mounting Options
Dimensions: mm Dimensional Drawing - Mounting Options Side Mounting Brackets Kit: PAT50386002 E G F C D B A A B C D E F G 25 11 20 10 6,3 50 1,9 Wall/Panel Bracket Kit: P699AT502467001 K J ØH D M 01813GB-2015/R01
More informationYour Plant Deserves Pure-Aire!
Your Plant Deserves Pure-Aire! PF Series High Efficiency Filters High Technology Filter Elements The Pure-Aire PF Series High Efficiency Unique Push-Fit, Double O-Ring Seal filter-to-head chamfered connection
More informationCOMPRESSED AIR FILTERS
VALUE THROUGH PERFORMANCE D SERIES COMPRESSED AIR FILTERS Combining Advanced Technology with Traditional Deltech Quality D Series Filters D Series Benefits Easy element changeout Bowl is hand-threaded
More informationRAZOR. RAZOR HVLP Spray Guns
RAZOR RAZOR HVLP Spray Guns Provides generous material flow that helps you get the job done quickly Offers exceptional atomization rate Promotes a superior finish Proven effective for clear coat, base
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More informationDY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动
DY Series 1-Piece Ball Valves Catalog 1001C-A July 2012 欧陆传动 aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Contents
More informationRotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003
Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003 PR Series Rotary Plug Valves Introduction Parker PR Series Plug Valves provide positive leak tight shut-off, high flow capacity, and quick
More informationPage General Purpose Filter Replacement Filter Elements Bowl Assemblies Accessories & Optional Extras
New Comprehensive Accessory & Maintenance Kit Listing Page.009 General Purpose Filter Replacement Filter Elements Assemblies Accessories & Optional Extras Page.05 Relief Valve Accessories and Optional
More informationAir Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.
Air Filtration CLEARPOINT energy saving compressed air filtration Truth in Compressed Air. At a Glance CLEARPOINT Filters uring compressed air generation and distribution, contaminants are introduced to
More informationAir service units series X G1/4 to G3/4
Air service units series X FX Filter.042 RX Pressure regulator.044 FRX Filter/regulator.046 OX Lubricator.048 FROX Two-piece air service unit.050 KX Ball valve.052 VMX 3/2-way inline valve.053 DAX Soft
More informationA-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories
Pneumatic Air Supply Manual 718 Filter Stations Section Product Bulletin Issue Date 0907 A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories Oil Removal and Pressure Reducing
More informationR1000/R3000/R4000/R8000 Series
Regulator R/R/R/R Series Compact pressure gauge integrated type : Rc/ to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R R R R Appearance Working fluid Max. working pressure Withstanding
More informationModel Model Model
Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging
More informationModular line 042 1/4. Regulator. Regulator
1 Modular line 1/ Regulator 5..5 3..3 1..1 3,5 1 7 INLET PRESSURE = 1 (1 ),3,,5 1,5 3 1 8 17,5 1 15 1 Regulator * Sensitive high performance model with rolling diaphragm; high stability with low load losses
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationPulse Width Modulation Valves. Models SPW-0 thru -7
November 2017 Bulletin / Bulletin 30-30 30-30 Page 1 Pulse Width Modulation s Models SPW-0 thru -7 Page 2 Bulletin 30-30 Pulse Width Modulation s For Refrigerant Flow Control in Direct Expansion HFC, HCFC
More informationInstallation & Service Instructions
49124597 Revision A August 2015 PacE Flow Controller, Replacement Kit Installation & Service Instructions Save These Instructions Table of contents INTRODUCTION...........................................................................
More informationBalston Stainless Steel Compressed Air Filters for Food Processing and Packaging
Balston Stainless Steel ompressed Air Filters for Food Processing and Packaging Bulletin SSompAirFood over Food.pmd 1 9/28/2005, 12:16 PM Stainless Steel ompressed Air Filters for Food Processing and Packaging
More informationF84V - Excelon Plus Modular System Oil vapour removal filters
> Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Adsorbing type activated
More informationF84G - Excelon Plus Modular System General purpose filter
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 5 or 40 micron particle and high efficiency water removal
More informationAir service units filters, regulators and lubricators
filters, regulators and lubricators Legris offers an extensive range of filters, regulators and lubricators, including individual units and combinations. s - eliminate dust and coagulation from compressed
More informationINSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR
Enidine / Conoflow 105 Commerce Way Westminster, SC 29693 Tel: (864) 647-9521 Fax: (864) 647-7993 WARNING Conoflow s products are designed and manufactured using materials and workmanship required to meet
More informationFILTERS, REGULATORS & LUBRICATORS
FILTERS, REGULATORS & LUBRICATORS Infinity filters remove solid particles and condensate produced by the compressor. The range includes standard filters, regulators and lubricators for points of use. OFR
More informationA-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories
A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Installation Applications The A-4000 Series Oil Removal and Pressure-Reducing Stations (see Figure 1, Figure 2, Figure
More informationFLEXIBLOK FRL Series
FRL Products and Accessories FLEXIBLOK FRL Series STOCKBLOK & MODUBLOK Combinations 14 14/22/32 Series Particulate Filters 20 14/22/32 Series Coalescing Filters 22 14/22/32 Series Regulators 24 14 Series
More informationFluid Power Accessories
Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 PNEUMATIC EXHAUST MUFFLERS Breather Vents 2,3 Exhaust Mufflers 2-5 Reclassifiers / Mufflers 6,7 BREATHER VENTS Speed
More informationPneumatic Valves Viking Lite Series. G1/8 - G3/8 body ported
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Pneumatic Valves Series G1/8 - G3/8 body ported Catalogue May 2015
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter Series Series / For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the F.R.L. combination
More informationF84C - Excelon Plus Modular System Oil removal filter
> Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > High efficiency oil and
More information1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S
16/26 SRIS O M P T & S T N R M O U L R I R P R P R T I O N S Y S T M S WILKRSON FILTRS, RGULTORS N LUBRITORS R26 Regulator F26 Filter L26 Lubricator M16 oalescing Filter B6 Filter/Regulator w/ Optional
More informationStainless Steel FRLs Air Preparation Units
Stainless Steel FRLs Air Preparation Units Catalogue no. PDE2504TCUK-ca Stainless Steel FRLs Air Line Filters /4 Miniature PF504... 4 /2 Standard PF0... 8 Air Line Coalescing Filters /4 Miniature PF50...
More informationINSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR
Enidine / Conoflow 105 Commerce Way Westminster, SC 29693 Tel: (864) 647-9521 Fax: (864) 647-7993 WARNING Conoflow s products are designed and manufactured using materials and workmanship required to meet
More informationModular FRLs. Pneumatic Mini Series G 1 /8 - G 1 /4. Modular Junior Series G 1 /8 to G 3 /8 Modular Maxi Series G 1 /4 to G 3 /4 Modular Series G1
Modular FRLs Pneumatic Mini Series G /8 - G /4 Modular Junior Series G /8 to G 3 /8 Modular Maxi Series G /4 to G 3 /4 Modular Series G Catalogue no. 258G-ca Mini IndexFRLs Mini FRLs Page o. Introduction
More informationSeries Airplus Size 1
Size 48 4 42 * 8 76 55 24 27.5.5 G/4 - G/8 Example : T7BL : size, Lubricator with Technopolymer threads, G/4" connections Inlet pressure (bar) 2,5 4 6, Pressure drop (bar), 2 4 6 8 2 4 6 Flow (Nl/min)
More informationIC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters
Page 1 of 5 ert. No. LRQ 0963008 Manual rain TI-P501-01 H Issue 5 I3, I3, I4 and I4 ISO 9001 Spirax-Monnier International Ultraclean ompressed ir Filters uto rain International Symbol escription The Spirax-Monnier
More informationACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump
ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page
More informationTable of Contents. Proportional & Precision Regulator Instrumentation
Table of Contents Proportional & Precision Regulator Instrumentation...3-27 Features and Benefits... 3 Electropneumatic Transducer...4-5 Economy Miniature Electropneumatic Transducer...6-7 Miniature Electropneumatic
More informationInside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.
Introducing GROZ Air - air control units ALUMINIUM DIE CAST BODY 01 02 WALL MOUNTING BRACKET FILTER UNIT 05 06 SINTERED BRONZE FILTERING ELEMENT (inside) 03 BUILT IN PIPING ADAPTERS PRESS TYPE MANUAL DRAIN
More informationFilters for Compressed Air
Fine Filtration Systems for Industry Product Information Filters for Compressed Air Tel: +49 (0) 6232 24021 Fax: +49 (0) 6232 24025 Email: info@headlinefilters.de Website: www.headlinefilters.de COALESCING
More informationModels P, P, P, , DANGER
Installation and maintenance guide Air filter Models 600104P, 600106P, 600108P, 600112, 600116 Date of issue January 2015 Form number 404646B Section G10 Page 31B DANGER Read manual prior to installation
More informationReady for outdoor use too!
Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior
More informationMetal Processing. SMC Actuators Built to Withstand Tough Environments
Metal Processing SMC products have been used in Metal Processing Applications. With SMC's vast array of pneumatic products, you are sure find the right product to meet your requirements. SMC Actuators
More informationDROPOUT A Unique Liquid Water Removal System
DROPOUT A Unique Liquid Water Removal System DROPOUT Liquid Water Removal Filters Guaranteed 99.999% liquid water removal. Particulate removal to 1 micron. Low cost of ownership. Maintenance free. Includes
More informationBall Valves (B Series) Catalog 4121-B January 2006
Ball Valves (B Series) Catalog 4121-B January 2006 B Series Ball Valves Catalog 4121-B Pressure vs. Temperature Pressure (psig) Temperature ( C) -54-18 10 38 66 93 121 149 177 204 232 6500 6000 448 414
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationAIR LINE ACCESSORIES 372
372 Series AIRPRO IN-LINE FILTERS Compressed air may contain impurities which will cause improper operation of equipment, and in some cases equipment failure. In-line filters will reduce downtime and prevent
More informationProduct Information ROSS CONTROLS
Product Information Minimize Hose Whip Flow Diffuser AIR-FUSE 19 Series ROSS CONTROLS AIR-FUSE Flow Diffusers Minimize Hose Whip 19 Series The ROSS AIR-FUSE Flow Diffuser automatically reduces air flow
More information300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)
INSTRUCTION MANUAL 300 Series Compressed Air Filters Models 302 (grade) through 317 (grade) FORM NO.: 3259480 REVISION: 01/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.
More informationIntroduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality
Pneumatic Actuators Catalog 4123-PA Revised, April 22 Introduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality
More informationBall Valves (B Series) Catalog 4121-B September 1999
Ball Valves (B Series) Catalog 4121-B September 1999 Two-Way B Series Ball Valves Introduction Parker manually, pneumatically, and electrically actuated two-way B Series Ball Valves provide quick 1/4 turn
More informationSUB-LINE FILTERS CONTENTS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORES PRODUCTS SUB-LE FILTERS CONTENTS SUB-LE FILTERS Features, Handling Instructions and Precautions 155 Line Filters Specifications,
More informationP33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Bulletin 0700-B3 ENGINEERING
More informationSinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001
Sinclair Collins Process Control Valves For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi April 2001 The Diaphragm Operated Valves on the following pages are designed for directing, diverting
More information611H Flo-Con Pressure Regulators & Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding 611H Flo-Con Regulators & Valves Catalog F-2, February 2012 Page 2
More informationELECTRONIC CONTROLLER
BRQB011206E THE INSIDE STORY OF THE QB3: IP65 enclosure allows it to withstand the elements and be washed down without harm Precision pressure control vacuum to 150 psi (10.34 bar ) at high flow rate saves
More informationP33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Catalogue PDE675TCUK October
More informationFTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE
FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg
More informationBL68 - Olympian Plus plug-in system Filter/regulators and lubricators
> > Port size: 3/4... /2 (ISO G/ PTF) > > Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More information