Lighting Havells Application Lamp Product No. Of Lamp Mounting Type Ballast Type Source Version Lamp Wattage ignitor Type Type

Size: px
Start display at page:

Download "Lighting Havells Application Lamp Product No. Of Lamp Mounting Type Ballast Type Source Version Lamp Wattage ignitor Type Type"

Transcription

1 Havells Item ogic ighting Havells Application Product o. Of Mounting Source Version Wattage ignitor H C C B = C = Commercial D = Domestic E = Emergency F = Flood ight G = Control Gear Box I = Industrial R = Roadway S = Sources V = Vapour Proof W = Well Glass Y = Spare Parts B = Blended MV C = CF F = Flourescent G = HPMV H = Tungsten Halogen = GS M = Metal Halide S = Sodium Vapour T = T5 FT W = Elliptical HID only Y = Tubular HID only Z = Both E/T HID To Choose from Commercial range mirror optic AS series 36W with multiple variables. Variables on Category louvres, ormal EM on Category louvres, 6.0W EM 1 Category ouvres, 6.0W EM 2 Category louvres, HF individual < 33% HCCC Category louvres, HF individual < 10% HCCC13361 A = MS white painted CAT III reflector (1) B = Specular finish Al. CAT III reflector (1) C = Specular finish Al. CAT II reflector (2) = on Category ouvre P = Polycarbonate ouvre HCC HCC HCCB = 1 2 = 2 3 = 3 4 = 4 CF s 09 = 9W CF 11 =11W CF 13 = 13W CF 18 = 18W CF/FP/FT 26 = 26W CF 36 = 36W FP/FT FT / T5 s 02 = 20W FT 04 = 40W FT 08 = 8W T5 FT 14 = 14W T5 FT 21 = 21W T5 FT = W T5 FT 54 = 54W T5 FT HID s 70 = 70W SV/MH 80 = 80W MV 12 = 125W MV 15 = 150W SV/MH 25 = 250W MV/SV/MH 40 = 400W MV/SV/MH 60 = 600W SV 10 = 1000W SV/MH For Commercial Fixture 1 = Armstrong ceiling 2 = Gypsum Board 3 = Recess mounting 4 = Surface mounting 6 = uxlon ceiling 7 = Pendent mounting For HID uminaires A = Short distance Ignitor suitable for SV only B = ong distance Ignitor suitable for SV/MH C = Super Imposed Ignitor D = Short distance Ignitor suitable for SV/MH For Fixture Fitted With 3 = 2700K 4 = 4000K 5 = 5000K 6 = 6500K FT/ FP OCB 07 = 2V, 18/20W FT/FP OCB 09 = 2V, 36/40W FT/FP OCB 11 = V, 36/40W FT/FP OCB 15 = V, 18/20W FT/FP OCB CF OCB 17 = 7/9/11W CF OCB 18 = 13W CF OCB 20 = 18W CF OCB 21 = 26W CF OCB Electronic s 26 = 1X36/40W FT EB THD<33% 27 = 2X36/40W FT EB THD<33% 32 = 1XW T5 FT EB THD<33% 33 = 2XW T5 FT EB THD<33% = 1X36/40W FT DB THD 10% 29 = 2X36/40W FT DB THD<10% 50 = 1XW T5 FT DB THD<10% 51 = 2XW T5 FT DB THD<10% 6

2 Guide to Symbols 7

3

4 A high intensity discharge lamp generally shows peculiar negative resistance characteristic, while striking the lamp it exhibits a very high impedance thus drawing no current. As starter circuit ignites, the arc establishes the current path between two electrodes. The impedance reduces fast and current rises. Unless this inrush current is controlled, lamp arc tube may lead to active failure. normally ensures that this current supplied to lamp is limited and established to desired level. Often therefore it is called current limiting device. popular in India are of two types : a) Electromagnetic b) Electronic. While electromagnetic ballast offer low power factor and compensating circuits are needed to improve it, electronic ballast invariably offer better power factor and are ideal for reliable ignition especially even at low voltage areas. Electromagnetic Selection of proper ballast not only ensures prolonging maintenance cycle but also helps optimization of lamp performance. A ballast like most electrical components, generates heat due to its ohmic resistance and magnetic losses. It is the temperature of the choke coil during operation that is important. The max permissible coil temperature tw is required to be marked on ballast. A tw value of 120 C is achieved with coil insulating class E. Under the specified conditions average ballast life of ten years may be expected for a continuous operations at coil temperature specified in tw C. However a 10 C temperature rise above tw C value will halve its expected life. A 20 C above tw value, a ballast life of not more than 2.5 years of continuous operation be expected. If ballast has no tw marking, a maximum of 105 C is assumed for the coil temperature. (Class A insulation tw is 105 C, Class E insulation tw is 120 C and for Class F insulation tw is 150 C.) Another value to be marked on any ballast is the coil temp rise Dt. This is differentiation between the absolute coil temp and ambient temp in standard condition. (This is measured as specified in IEC 920 (E 60920). Common values for Dt are from 50 C to 70 C in steps of 5 C). A ballast selected therefore marked with say tw 120 and Dt 70 will have specified 10 years average life in continuous operation at standard condition at an ambient temperature of 120 C-70 C = 50 C. If ambient around ballast is higher, shorter ballast life will result unless adequate air circulation in cooling is applied within gear compartment. The ambient temperature of 50 C indicated is not a room temperature or environmental temperature but is a temperature of the microenvironment of the ballast. in luminaire or control gear, the air temperature around it is higher than outside ambient temperature. Therefore higher temperature has to be added to coil temperature rise Dt to find absolute coil temperature tc = t2 + Dt. losses published are maximum cold values. Published Dt & tw ratings are for standard conditions and shall vary differently in different enclosures if measured. For perennial low voltage areas ballast lower tappings rating can be used. A caution is however needed if voltage shows tendancy to rise beyond the rated voltage in late night hours, if used in lower tapping; premature failure of ballast may be inevitable. Electronic To over come the heat, ignition at low voltage and circuit compensation problems, it is prudent to select more refined yet energy saving ballast commonly available for fluorescent and selectively available for low wattage HID circuits. The vagaries of Indian mains supply across the country must protect the ballast from malfunction. Multiple types of ballasts are available in market. A guidance therefore is necessary for unsuspecting purchaser, following are few of the tips: Instant start EB is essentially cold start ballast and do inflict damage to filament of FT if used in multi switching (>3 cycles/ day) installation. life is reduced. Rapid start EB is (pre-heat) warm start ballast and prolongs the life of FT to its declared life and is ideal for multi switching installation. Circuit protection to be built-in are: In-rush current protection a must in Instant Start EB, while Rapid Start it is not warranted. Source aging protection will lead to safety of the ballast during aging of lamp. Over voltage auto shut off circuit. It will ensure that the circuit shuts off in case of mains voltage over shoots the specified designed voltage (0 - V) Preheat current in warm start EB should be reduced to minimum once the filament temperature reaches 700K. Else the continuous pre-heat current leads to premature failure of filament. Published series in this catalogue of industrial and domestic electronic ballast confirm to relevant standards. Our digital ballast series are Active Circuits (APFC) and are constant wattage output ballast for wide range of mains voltage variance ( V). The service life of our Digital ballast in standard condition is in excess of hours with failure rate of less than 2 for every 100 ballast installed in 3 phase 4 wire balanced circuit installations. Our complete range of electronic ballasts operate at >40 KHz and are immune to infra-red remote operations. These are designed for complete hum and flicker free operations for your safety. Published data is as per specified test procedures laid in relevant BIS & IEC publications. These are measured in stand alone condition at 2V, 50Hz for domestic products and V, 50Hz for industrial products at perfect sinusoidal wave form. At actual working environment due to variance in mains supply wave form and frequency this publish data may show changes if THD and frequency level of the utility supply is not as per the norms. ote: All types of ballast especially HID and electronic, are exposed to premature failure if these are run with the lamps reaching its end of service life. It is advisable therefore to ensure that lamps/tubes are replaced at the end of its service life rather than awaiting lamp failure to occure. 9

5 Deep Drawn Pack Out door heavy duty Deep Drawn (DD) body control gear box housing suitable for single High Pressure Sodium Vapour/ Metal Halide lamp upto 250W. Deep drawn from EDD grade MS body housing with powder coated in siemen s grey shade. Built in tray facilitates housing of ballast, ignitor and capacitor mounting. 3 knock-outs provided help loop-in-loop out connections if required (change the mains i/c connector to proper circuit amp. rating). Fixed with quick release side toggels help secure weather proof cover in normal operation. Hooked in connection for cover ensures easy maintenance of components Mounting brackets at back helps rigid fi xing of CG box on to structure. Bottom knock-out for cable entry for terminating in improved quality glass fi lled connectors. Pre wired with power factor improvement capacitor and impulse ignitor for reliable ignition upto terminal block, copper wound ferromagnetic ballast supplied separately be wired as per instruction. 85±2 113±1 198±2 Ø19 225±2 Front View Capacitor Value (mfd) Cap R Y lgn B mtrs. HGW02170B99 HBW HGW02115B99 HBW HGW02125B99 HBW x70W SV/MH 1x150W SV/MH 1x250W SV/MH For HPSV/ MH lamp with impulse ignitor - HW17000B99 10

6 Deep Drawn Pack Out door heavy duty Deep Drawn (DD) body control gear box housing suitable for single High Pressure Sodium Vapour/ Metal Halide lamp upto 400W. 168±1 Aerodynamic shaped deep drawn from EDD grade MS body housing with powder coated in siemen s grey shade. Built in tray facilitates housing of ballast, ignitor and capacitor mounting. 3 knock-outs provided help loop-in-loop out connections if required (change the mains i/c connector to proper circuit amp. rating). Fixed with quick release side toggels help secure weather proof cover in normal operation. Hooked in connection for cover ensures easy maintenance of components Mounting brackets at back helps rigid fi xing of CG box on to structure. Bottom knock-out for cable entry for terminating in improved quality glass fi lled connectors. Pre wired with power factor improvement capacitor and impulse ignitor for reliable ignition upto terminal block, copper wound ferromagnetic ballast supplied separately be wired as per instruction. 290±1 126±2 Ø19 201±2 Front View HGW02140B99 HBW Capacitor Value (mfd) 1x400W SO/MH Cap R Y lgn For HPSV/ MH lamp with impulse ignitor - HW17000B99 B mtrs. 11

7 Cast-Aluminium Pack Out door heavy duty cast aluminium (CA) body control gear box housing suitable for single High Pressure Sodium Vapour/ Metal Halide lamp upto 250W. Die-cast aluminium body housing with textured powder coated siemen s grey shade. Body mounted ballast, ignitor and capacitor helps better heat dissipation. 3 knock-outs at bottom help loop-in-loop out connections if required (change the mains i/c connector to proper circuit amp. rating). Good quality hardware ensures long life maintenability. Built in mounting arrangement in body housing ensures rigid 1 fi xing on mounting structure. Pre wired with power factor improvement capacitor and impulse ignitor for reliable ignition upto terminal block, copper wound ferromagnetic ballast supplied separately be wired as per instruction. 85±2 90±1 186±2 Ø17 222±2 Front View Capacitor Value (mfd) Cap R Y lgn B mtrs. HGW04170B99 HBW HGW04115B99 HBW HGW04125B99 HBW x70W SO/MH 1x150W SO/MH 1x250W SO/MH For HPSV/ MH lamp with impulse ignitor - HW17000B99 12

8 Cast-Aluminium Pack Out door heavy duty cast aluminium (CA) body control gear box housing suitable for single High Pressure Sodium Vapour/ Metal Halide lamp upto 400W. Die-cast aluminium body housing with textured powder coated siemen s grey shade. Body mounted ballast, ignitor and capacitor helps better heat dissipation. 3 knock-outs at bottom help loop-in-loop out connections if required (change the mains i/c connector to proper circuit amp. rating). Good quality hardware ensures long life maintenability. Built in mounting arrangement in body housing ensures rigid 1 fi xing on mounting structure. Pre wired with power factor improvement capacitor and impulse ignitor for reliable ignition upto terminal block, copper wound ferromagnetic ballast supplied separately be wired as per instruction ±2 1±2 Ø17 Cap 220±2 Front View R Y lgn For HPSV/ MH lamp with impulse ignitor - HW17000B99 B mtrs. HGW03140B99 HBW Capacitor Value (mfd) 1x400W SO/MH

9 CA Pack for Double Out door heavy duty cast aluminium (CA) body control gear box housing suitable for double High Pressure Sodium Vapour/ Metal Halide lamps upto 400W. Die-cast aluminium body housing with textured powder coated siemen s grey shade. Body mounted ballast, ignitor and capacitor helps better heat dissipation. 3 knock-outs at bottom help loop-in-loop out connections if required (change the mains i/c connector to proper circuit amp rating). Good quality hardware ensures long life maintenability. Built in mounting arrangement in body housing ensures rigid 1 fi xing on mounting structure. Pre wired with power factor improvement capacitor and impulse ignitor for reliable ignition upto terminal block, copper wound ferromagnetic ballast supplied separately be wired as per instruction ±2 160±2 2±2 Ø17 3±2 Front View Capacitor Value (mfd) mtrs. HGW04225B99 HBW HGW04B99 HBW x250W SO/MH 2x400W SO/MH x33.0 2x42.0 Cap R Y lgn B For HPSV/ MH lamp with impulse ignitor - HW17000B99 14

10 Composite Gear Unit Compact encapsulated electromagnetic copper wound integrated CGU for reliable ignition of 70/150W HID SO/MH lamps for indoor use. Compact size encapsulated copper wound gear integrated with Short distance ignitor and power factor improvement capacitor. Electrical grade steel and double insulated grade enamel wire ensures long and reliable operation. Built in capacitor eliminates external wiring of compensation circuits. Designed for only indoor/ shielded out door environments. Hazardous if used in exposed out door conditions. Designated mains and lamp terminals for ease of direct wiring. Dimension Details ength ( in mm) Width (W in mm) Height (H in mm) (in mm) 1x70W SO/MH 1x150W SO/MH 190±2 210±2 78±2 78±2 65±2 65±2 176±1 194±1 Front View Capacitor Value (mfd) HGW41170D36 HGW41115D36 1x70W SO/MH 1x150W SO/MH * for indore use only. Distance limit between CGU & - 5mtr. AMP CGU MAIS AMP 15

11 ugget Compact encapsulated in engineering plastic FR grade cover, electromagnetic copper wound integrated gear unit for reliable ignition of 70/150W HID SO/MH lamps for indoor use. Cover made-up of heat resistant engg. plastic FR grade to prevent fi re Compact size encapsulated copper wound gear integrated with Short distance ignitor and power factor improvement capacitor Electrical grade steel and double insulated grade enamel wire ensures long and reliable operation Built in capacitor eliminates external wiring of compensation circuits Designed for only indoor/ shielded out door environments. Hazardous if used in exposed out door conditions Designated mains and lamp terminals for ease of direct wiring Dimension Details ~M 68.3± x70W SO/MH 1x150W SO/MH ength ( in mm) 176±2 176±2 Width (W in mm) 81±2 81±2 Height (H in mm) 68.5±2 68.5±2 (in mm) 162±1 162±1 176 Front View Capacitor Value (mfd) HGW42170D36 HGW42115D36 1x70W SO/MH 1x150W SO/MH MAIS CGU AMP AMP 16

12 Open Construction (OC) Industrial grade vaccum impregnated (VPIT) ballast designed to be operated at 220V-V/50Hz mains supply. Suitable for HPMV/SV/MH lamps. Compact in size Designed for V/ 50Hz., AC supply ow loss silicon steel lamination Super enamelled copper wire Vaccum impregnated (VPIT) open construction ow watt loss Better heat dissipation Hum free operation 0 Maximum winding temp. tw- 1 C, Temp. rise., t C ong life Conforms to IS: , IEC 922 & IEC 923 Dimension Details ength ( in mm) Width (W in mm) Height (H in mm) (in mm) H 1x35W MT/MH 1x70W SO/MH 1x150W SO/MH 1x250W SO/MH EW 1x400W SO/MH 1x125W HPMV 1x250W HPMV 1x400W HPMV 117±1 112±1 147±2 147±2 147±2 147±2 147±2 147±2 60±1 64±1 64±1 102±2 102±2 102±2 102±2 102±2 52±1 57±1 57±1 91±2 91±2 91±2 91±2 91±2 92±1 92±1 1±1 134x80 134x80 134x80 134x80 134x80 Front View Connector W Side View 5mtrs. Cap For HPSV/ MH lamp with impulse ignitor - HM05000D99/ HW07000A99 mtrs. Cap R R Y lgn Y lgn B B HBM HBW HBW HBW * HBW HBG HBG HBG x35W MT/MH 1x70W SO/MH 1x150W SO/MH 1x250W SO/MH EW 1x400W SO/MH 1x125W HPMV 1x250W HPMV 1x400W HPMV * Base plate & stack design as per 400W SO/MH OC ballast >0.45 >0.36 >0.41 >0.39 >0.43 >0.52 >0.53 >0.55 For HPSV/ MH lamp with impulse ignitor - HW17000B99 5mtrs. Cap B lgn p For HPSV/ MH lamp with super imposed ignitor - HW27000C99 17

13 Electronic Industrial electronic HID ballast suitable for 35W/70W/150W ceramic Metal Halide lamp. Suitable for 220-V/ 50Hz Ignition time <2 secs Crest (CF) <1.70 Output Frequency >150Hz High power factor (PF) Total Harmonic Distortion (THD) <10% IR radiation immune, hum free operation Advantages: Optimal lamp control & operation Micro processor control & monitoring of operation status Comfortable operation onger lamp life Push-fit type connector ow energy consumption with low heat generation Conforms to IEC 61547/ IEC Programmed APFC regulated high frequency ballast for multiple switching cycle Dimension Details U-OUT=350V AMP H H W 1x35W CMI 1x70W CMI 1x150W CMI ength ( in mm) 110±2 110±2 165±2 Width (W in mm) 75±2 75±2 91±2 Height (H in mm) 33±1 33±1 39±1 (in mm) 96±1 96±1 157x74 Front View Wattloss (W) HBI HBI HBI x35W CMI 1x70W CMI 1x150W CMI

14 Copper Industrial grade vaccum impregnated (VPIT) ballast designed to be operated at 220V-V/ 50Hz mains supply. Also available in low loss (ACCURA) version. Compact in size Designed for V/ 50Hz., AC supply ow loss silicon steel lamination Super enamelled copper wire Vaccum impregnated (VPIT) open construction ow watt loss (less than12w) Better heat dissipation Hum free operation Maximum winding temp. tw C, Temp. rise., Dt C ong life Conforms to IS: 1534(Part1) of 1977 W Dimension Details ength ( in mm) Width (W in mm) Height (H in mm) (in mm) H 1x18/20W FT/FP- 1x36/40W FT/FP- 1x26W P-C 137±2 137±2 137±2 41±1 41±1 41±1 33±1 33±1 33±1 115±1 115±1 115±1 Side View Cap For Single tube of 18/20/36/40W FT with universal starter (FSU) Cap S HBF HBF HBC x18/20W FT/FP- 1x36/40W FT/FP- 1x26W P-C Wattloss (W) >0.42 >0.52 >0.50 S For twin tubes of 18/20W FT with 110V starter (FS2) S 19

15 CF Electronic Compact, high frequency, energy effi cient electronic ballast suitable for 2 pin & 4 pin CF. 2 Pin/4 Pin CF electronic ballast: Economical solution for energy saving in low voltage areas of rural India. Suitable for non-retrofi t CF. Rated Voltage : V/ 50Hz (PF) : >0.55 Crest (CF) : <1.80 Output Frequency : KHz Total Harmonic Distortion (THD) : <140% 4 Pin 86±1 2 Pin 99±2 tc 45±0.5 4 Pin CF electronic ballast: Economical solution for energy saving in low voltage areas of rural India. Suitable for non-retrofi t CF. Rated Voltage : V/ 50Hz (PF) : >0.90 Crest (CF) : <2.0 Output Frequency : KHz Total Harmonic Distortion (THD) : <50% Advantages: Compact in size, energy effi cient and with universal mounting holes for easy replacement of electromagnetic ballast. Ideal for areas of low voltage pick-ups ±0.5 Side View Wattloss (W) 4Pin CF EB HBC07115 HBC * HBC Pin/4Pin CF EB HBC07114 HBC x9/11/13W CF 1x18W CF 1x26W CF 1x9/11/13W CF 1x18W CF >0.90 >0.90 >0.55 >0.55 >0.55 4Pin Pin * ot suitable for FP- 20

16 Industrial Electronic - High Performance Industrial electronic ballast suitable for single or twin T12/ T10/ T8/ T5 linear fl uorescent lamps. In-built preheat start and cut-off circuits ensure enhanced lamp life with failure resistant ballast. Suitable for 220-V/ 50Hz Ignition time <2 secs Crest (CF) <1.90 Output Frequency >40KHz High power factor (PF) >0.95 Total Harmonic Distortion (THD) <33% IR radiation immune, hum free operation Circuit designed for higher (0V) mains voltage & ageing protection W H Advantages: onger lamp life Push-fi t type connector Striation free operation ow energy consumption with low heat generation Programmed warm start (pre-heat) circuit enables lamps for multiple switching cycles Conforms to E 609 & E Dimension Details Side View 1x14W T5 FT 2x14W T5 FT 1xW T5 FT 2xW T5 FT 1x54W T5 FT 1x36/40W FT 2x36/40W FT 2x18/20W FT 1x24W FT 2x24W FT ength ( in mm) Width (W in mm) Height (H in mm) (in mm) 254±1 254±1 E BAAST Wattloss (W) E For Single BAAST HBT HBT # HBT HBT # HBT HBF HBF # HBF HBT01124 HBT01234 # 1x14W T5 FT 2x14W T5 FT 1xW T5 FT 2xW T5 FT 1x54W T5 FT 1x36/40W FT 2x36/40W FT 2x18/20W FT 1x24W FT 2x24W FT >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 For Twin # Independent lamp opration feature available in electronic ballast suitable for twin FT. 21

17 Olympian Electronic Compact, high frequency, energy effi cient ballast suitable for single T12/T8 linear fl uorescent lamp or 18/36W FP-. Available in basic circuit or with over voltage and end of life protection circuits. Olympian electronic ballast: Suitable for domestic/ indusrial application. Suitable for linear fl uorescent (FT) lamp/ fl uorescent parallel lamp (FP-). Designed to protect from high voltage surge (0-315V) and ageing protection. Rated Voltage : 220-V/ 50Hz (PF) : >0.94 Crest (CF) : <1.90 Output Frequency : KHz Total Harmonic Distortion (THD) : <33% 115±2 Advantages: is pre-wired, compact in size, energy effi cient and with universal mounting holes for easy replacement of electromagnetic ballast. Ideal for areas of low voltage pick-ups. ±1 40±2 33±2 1±2 Side View Electronic Wattloss (W) HBF x36/40W FT >0.94 For 1x18/20/36/40W FT Electronic For 1x36W FP- 22

18 Industrial Electronic - Digital PerformanceIndustrial electronic digital performance ballast suitable for single or twin T12/T10/T8/T5 linear fluorescent lamps. Designed for specific hum-free application areas where much lower harmonic distortion desirable. Suitable for 220-V/ 50Hz Ignition time <2 secs Crest (CF) <1.75 Output Frequency >40KHz High power factor (PF) Total Harmonic Distortion (THD) <10% IR radiation immune, hum free operation Circuit designed for higher (0V) mains voltage & ageing protection W H Advantages: onger lamp life Push-fit type connector Striation free operation ow energy consumption with low heat generation Programmed APFC regulated high frequency ballast perfect for multiple switching cycles Conforms to E 609 & E Dimension Details Side View 2x14W T5 FT 2x24W T5 FT HO 1xW T5 FT 2xW T5 FT SIM 2xW T5 FT 1x36/40W FT 2x36/40W FT ength ( in mm) Width (W in mm) Height (H in mm) (in mm) 355±1 254±1 254±1 E BAAST Voltage (V) Current (A) Wattloss (W) E For Single BAAST HBT HBT02242 HBT HBT HBT HBF HBF x14W T5 FT 2x24W T5 FT HO 1xW T5 FT 1xW T5 FT SIM 2xW T5 FT 1x36/40W FT 2x36/40W FT For Twin 23

19 Analog Dimmable Energy saving HF electronic analog dimmable ballast suitable for dimming single or twin T8/T5/FP- fl uorescent lamps. Designed for use with Aura Energy Management systems for dimming applications. Dimmable Analog (1-10V DC) HF Electronic ballast Rated Voltage : 2V/V AC, 50Hz Control input : 1 10V DC, 0.5mA (PF) : 0.98 Total Harmonic Distortion (THD) : < 15% ong service life Complies with IEC /2-3, IEC /3, E60929, E55015, E ±1 Advantages Energy savings by dimming capabilities (1-100% T8, 3-100% T5, 5-100% FP-) 50% onger lamp life than with conventional ballasts Desired illumination levels creating effi cient working conditions Auto reset after lamp replacement comforms to E 609 & E dimmable Electronic Analog Dimmable Ord. : ACUBT ±1.3±1 360±2 Front View Voltage (V) Dimming evel ACUBP ACUBP0504 ACUBT ACUBT ACUBF ACUBF x18,, 36W T8 FT 1x18, 24, 36, 40W FP- 2x18,, 36W T8 FT 2x18, 24, 36, 40W FP- 1x14, 21,, 35W T5 2x14, 21,, 35W T5 1x54W T5 1x58W T8 2x54W T5 2x58W T %-100% 5%-100% 1%-100% 5%-100% 3%-100% 3%-100% 3%-100% 3%-100% 3%-100% 3%-100% 24

20 Ignitors Electronic ignitors for variety of gas discharge lamps of multiple wattages. Wiring Diagram Designed to give reliable initial ignition voltage pulse to facilitate the discharge in HID arc tubes. Active until the lamp current sets in Designed voltage peak occur at the correct phase angle for ignition HF pulses can be transfered only over short distance as per the Approved load capacity of Ign (pf) guidance below Distance(m) = Actual supply line capacity (pf) Impulse (semi - parallel) & Superimposed pulse SIP (series/parallel) versions available. Seperate wired lead for direct ballast terminations eliminates voltage (pulse) drops at multiple junctions. Short and long distance versions ensure quick and reliable ignition to most of HID lamps under 220/2/V, 50Hz mains supply conditions. For hard strike lamps (aged lamps /MH) higher pulse amplitude may be necessary. Complies with E (safety) and E (Performance) HM05000D99/ HM07000D99 Dimension Details Description ength () Dia (D) HM05000D99 3 lead ignitor (SD) Upto 400W HPSV/MH HW17000B99 3 lead ignitor (D) Upto 400W HPSV/MH HW27000C99 S.I 3 lead ignitor with stud (Al. Can) Upto 400W HPSV/MH HM05000E99 S.I 2 lead ignitor with stud Upto 400W HPSV/MH HM07000D99 D type 3 lead ignitor with stud Upto 400W HPSV/MH Description Suitable upto Distance (in mtrs) o. of Pulses Pulse height (in Kv) HM05000E99 HM05000D99 HW17000B99 HW27000C99 HM05000E99 HM07000D99 3 lead ignitor (SD) 3 lead ignitor (D) S.I 3 lead ignitor with stud (Al. Can) S.I 2 lead ignitor with stud D type 3 lead ignitor with stud Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH 5 mtrs mtrs 5 mtrs 5 mtrs 5 mtrs 1 per cycle 3 per 5 cycle 6 per cycle 5 per cycle 1 per cycle Kv Kv Kv Kv Kv 25

21 Capacitors Housing made up of PVC Film used is MPP (Metallised Poly Propylene) With in-built resistant for protection Wire-end soldered for easy connections Wire open 12.5mm each Wire should be soldered 180mm length black wire 0.5mm2 multi stand 16/0.20mm CAPACITOR IS: MFD ± 10% 250 V AC 50 Hz -10/85/21 MPP.SP. HAVES IDIA TD. D ength ( in mm) Dia (D in mm) Tolerance HZF HZF HZZ HZZ HZZ HZZ HZZ MFD 8 MFD 10 MFD 15 MFD 20 MFD 33 MFD 42 MFD Ø Ø Ø35 Ø35 Ø40 Ø40 Ø ±10% ±10% ±10% ±10% ±10% ±5% ±5% 26

Control gear/ballast. damage to filament of FTL if used in multi switching (>3 cycles/ day) installation. Lamp life is reduced.

Control gear/ballast. damage to filament of FTL if used in multi switching (>3 cycles/ day) installation. Lamp life is reduced. Control gear/ballast A high intensity discharge lamp generally shows peculiar negative resistance characteristic, while striking the lamp it exhibits a very high impedance thus drawing no current. As starter

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

Specification for 400W Industrial Highbay Luminaire and lamp

Specification for 400W Industrial Highbay Luminaire and lamp Specification for 400W Industrial Highbay Luminaire and lamp Sl.No. Description for BHEL Requirement Specified / To be confirmed Supply of High Performance, Integral, Industrial, High Bay, open version

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Lighting Tables for New Equipment 2/24/2015

Lighting Tables for New Equipment 2/24/2015 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---

More information

GECAP24400V0 Capacitor For 400W MH BLST

GECAP24400V0 Capacitor For 400W MH BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 GECAP24400V0 Capacitor For 400W MH BLST G.E. Lighting (blst) Catalog Number Manufacturer Description per unit Product

More information

Switchgear for Luminaires

Switchgear for Luminaires www.eaton.com www.moeller.net Switchgear for Luminaires Technical Paper Dipl.-Ing. Dirk Meyer Mr. Dirk Meyer (Dipl.-Ing.) Division Industrial Automation Division Electromechanical motor starter product

More information

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Induction Compact Fluorescent HID LPQ. Canopy Luminaire Induction Compact Fluorescent HID LPQ Canopy Luminaire LPQ Series Lighting For Life Featuring the Philips QL Induction Lighting System 100,000 Hours of Operation Very Low Maintenance Efficient Operation

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Lighting Tables for New Equipment 3/9/2016

Lighting Tables for New Equipment 3/9/2016 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL Thank you for choosing PARsource Lighting Solutions for your installation. Our fixture designs are initiated by grower feedback, and implemented

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear W, W, W, 1W, 2W, W & W DATA SHEE T Lucalox TM XO Elliptical Diffuse W, W, W, 1W, 2W & W Product information

More information

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W GE Lighting Lucalox PSL Lucalox PSL Tubular Clear 23V 25W, 4W, 6W and 75W Lucalox PSL Tubular Clear 4V 6W and 75W Superb performance and high reliability DATASHEET GE s advanced sodium resistant ceramic

More information

Lighting Tables for New Equipment 1/1/2018

Lighting Tables for New Equipment 1/1/2018 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00

More information

Lo-Pro Canopy Mount Integrated Linear Continuous Surface illumination

Lo-Pro Canopy Mount Integrated Linear Continuous Surface illumination Housing Extruded 6063 T6 aluminum in standard lengths to 8'. onger runs and complex layouts easily accomplished with internal joining system and precision mitred corners. Reflector Specular linear parabolic

More information

WALKIE CAR. design: Martini Staff

WALKIE CAR. design: Martini Staff 150 / 151 WALKIE CAR design: Martini Staff WALKIE CAR 230/300 recessed drive-over Walkie Car 230 Walkie Car 300 Body Light sources Emissions Colours floor-recessed luminaire, die-cast aluminium body and

More information

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 Page LED Roadway Lighting Atlas Basic LED Roadway...1-2 ROADWAY LIGHTING Atlas LED Roadway...3-4 Atlas Evo LED Roadway I...5-6 Atlas Evo LED Roadway

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles.

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles. TUBE TUBE TUBE family is available in 4 different sizes. They are protected from the ingress of dust and water and are used in both outdoor and indoor environments. Operating with PAR, Compact Fluorescent,

More information

GE Lighting DATA SHEET. Product information. Features. Applications

GE Lighting DATA SHEET. Product information. Features. Applications GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 5W, 7W, W, 15W, 25W, 4W & 6W Lucalox TM XO Elliptical Diffuse 5W, 7W, W, 15W, 25W & 4W DATA SHEET

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

High Efficiency Lighting units

High Efficiency Lighting units High Efficiency Lighting units Current Eligibility Criteria Various combinations of Lighting Fitting with Associated Control Gear and Lamp(s) meet the criteria for a High Efficiency lighting Unit. For

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Lighting Induction Code Master 2 Factory Sealed Induction Lighting System NEC/CEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside

More information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof Code Master 2 Factory Sealed Induction Lighting System Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) NEMA 4X

More information

Lamps. In this section.

Lamps. In this section. In this section 7.1 Halogen amps 7.3 Compact Fluorescent amps 7.6 Fluorescent amps 7.7 High Intensity Discharge amps www.ecolifelighting.co.nz amps amps Once the light fittings have been selected, the

More information

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps Reliability with the most essential intellect Philips HF-Essential Electronic ballasts for TL5 lamps HF-Essential - Reliability with the most essential intellect Electronic ballasts for TL5 lamps The cost-saving

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

Component Systems. for Lighting Applications. January 2018

Component Systems. for Lighting Applications. January 2018 Component Systems for Lighting Applications January 2018 Magnetic and Electronic Ballasts Ignitors Capacitors Electronic LVH Converters Emergency Lighting Modules Electronic Fluorescent Ballasts Lampholders

More information

Induction lamps and control gear

Induction lamps and control gear Induction lamps and control gear The QL lamp systems are based on a unique physical principle of light generation: the QL induction technology. The QL induction technology is a breakthrough for professional

More information

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40 GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965

More information

L I G H T W A V UV Electronic Ballast E 2010

L I G H T W A V UV Electronic Ballast E 2010 L I G H T W A V UV Electronic Ballast 2010 E LIGHTWAVE High Frequency Electronic Ballast Function of an UV ballast To provide the proper voltage and current such that a steady plasma can be established

More information

Let's conserve energy for nation's progress. An ISO 9001: Co. IS: Manufacturers of :CAPACITOR GRADE METALLISED

Let's conserve energy for nation's progress. An ISO 9001: Co. IS: Manufacturers of :CAPACITOR GRADE METALLISED An ISO 9001: 8 Co. Manufacturers of :CAPACITOR RADE METALLISED PLASTIC FILM AC CAPACITORS MFD START CAPACITORS DUAL RATIN CAPACITORS BURST PROOF CAPACITORS FLUORESCENT & DISCHARE LAMP CAPACITORS U V LAMP

More information

Lucalox Standard. GE Lighting. Product information. Applications areas

Lucalox Standard. GE Lighting. Product information. Applications areas GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

Call us on: LED...P2-35 SON/Metal Halide...P36-40 Lighting Control Gear...P41-51

Call us on: LED...P2-35 SON/Metal Halide...P36-40 Lighting Control Gear...P41-51 Call us on: 01299 251 058 ED...P2-35 SON/Metal Halide...P36-40 ighting Control Gear...P41-51 ED GU10 GU10 240V Retrofit FIG 1 FIG 2 FIG 3 Aluminium Reflector umens Colour Cap 133420 3.6 35 250 3K GU10

More information

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps T5 T8 TC-F TC-L T5c PC T5 PRO-M lp, 14 80 W T5, T8, compact (CFL) and T5c circular fluorescent lamps Product description Integrated lamp detection Operation of T5 lamps of the same length Average life

More information

MACH 3 D10,5 D10,5 D10,5. Light as star

MACH 3 D10,5 D10,5 D10,5. Light as star 11 116 335 379 MACH 3 246 6 6 D1,5 D1,5 D1,5 Light as star The Mach 3 floodlight has been designed to offer the ultimate in technical prowess, especially with regard to new, high-performing sources of

More information

manufacturing & testing facilities - Haridwar, Noida

manufacturing & testing facilities - Haridwar, Noida manufacturing & testing facilities - Haridwar, Noida Contents LED lighting DOMESTIC & RETAIL 6-7 LAMPS & TUBES 8 Professional 9-10 CONVENTIONAL lighting Domestic & Retail 12-13 Commercial 14-16 Industrial

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For T fluorescent lamps ow-profile casing ( x 0 mm cross-section) -year guarantee Properties or h rated

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

Constant wattage for high intensity discharge (HID) lamps

Constant wattage for high intensity discharge (HID) lamps onstant wattage for high intensity discharge (HID) lamps Index page Introduction 143 onstant wattage control equipment 144 onstant wattage application 145 onstant wattage mercury vapour and metal halide

More information

Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with

Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with T8 Standard...High efficiency, smaller diameter, energy-saving and long-life

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

T U N N E L A N D U N D E R P A S S LIGHTING

T U N N E L A N D U N D E R P A S S LIGHTING T U N N E L A N D U N D E R P A S S LIGHTING Indoor Indoor Tunnelite TGX220 Tunnel luminaire suitable for use with 18-58W TL-D lamps. Tunnelite TGX220 Type Features Light source Lamp included Gear Optic

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

VEL2P75S35I 2-F96T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description

More information

MAGNETIC HID BALLASTS

MAGNETIC HID BALLASTS Philips dvance HID ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, HID lamps are

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

FLOODLIGHTS FASTLED DATASHEET

FLOODLIGHTS FASTLED DATASHEET FLOODLIGHTS FASTLED DATASHEET floodlights High-efficiency LED floodlight. Available with colour temperatures 3000 K-4000 K-6000 K RGB (only in the 36-LED version) Equipped with secondary optical beams:

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

FLUORESCENT INDUCTION

FLUORESCENT INDUCTION FLUORESCENT INDUCTION Electrodeless Lamp OPENING NEW FRONTIERS FOR LIGHTING IT IS IMPOSSIBLE TO IMAGINE MODERN LIFE WITHOUT ELECTRIC LIGHTING. WITH THE WIDE AVAILABILITY AND AFFORDABILITY OF TODAY S LIGHTING,

More information

FOLDER-II दर अ स च (एसओआर) SCHEDULE OF RATES [PRICED SOR] (FINANCIAL / PRICE BID)

FOLDER-II दर अ स च (एसओआर) SCHEDULE OF RATES [PRICED SOR] (FINANCIAL / PRICE BID) FOLDER-II दर अ स च (एसओआर) SCHEDULE OF RATES [PRICED SOR] (FINANCIAL / PRICE BID) [Scan copy to be uploaded in Folder II (FINANCIAL/ PRICE BID)] SCHEDULE OF RATES (SOR) - PRICED BID (BIDDER TO MENTION

More information

High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens

High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens Part #: GAU-HB-160LED Page: 1 The Larson Electronics GAU-HB-160LED High Bay LED Light Fixture provides operators with a powerful and energy

More information

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting LEDAZ Solution meets clients every lighting requirement, covering a wide range of product portfolio including LED Reflector, LED Downlight, LED Tube, LED Plug-in Tube, LED Sensor Batten and LED Floodlight.

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID BALLASTS Precision. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Electronic HID Ballasts Electronic HID ballasts have been designed from

More information

The Power Behind Energy

The Power Behind Energy CONTENTS HID ELECTRONIC BALLASTS Page 1 HID DIMMABLE ELECTRONIC BALLASTS Page 6 Copyright DNA UK LTD 11 HID ELECTRONIC BALLASTS Product Features Options of dimmable ballasts via 1-10V or IPM (Intelligent

More information

manufacturing & testing facilities - Haridwar, Noida

manufacturing & testing facilities - Haridwar, Noida manufacturing & testing facilities - Haridwar, Noida Contents LED lighting DOMESTIC & RETAIL 6-8 LAMPS & TUBES 9 Professional 10-13 CONVENTIONAL lighting Domestic & Retail 15-16 Commercial 17-18 Industrial

More information

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing ( x 0 mm cross-section) Properties or h rated duration Compatible with all

More information

APOLO. High/Low bay reflectors

APOLO. High/Low bay reflectors APOLO High/Low bay reflectors APOLO High/Low Bay Reflectors APOLO industrial high/low bay reflector luminaire is Megalite state of the art design for suspended mounting with angle adjustment capability

More information

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

SPECIFICATION SHEET ORION ROAD LANTERN.   IP66 RATED CRI. 230v /50hz ORION ROAD LANTERN Arc shape cooling guide design, resulting in effective heat dissipation and dust removal ability Combined optical lens, ideal for road lighting requirements Power-off protection socket,

More information

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2S40SC35I 2 F34T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

Technical information. Lamp data Light tubes

Technical information. Lamp data Light tubes Light tubes Light tubes produce light when a starter generates an electrical pulse, which starts a discharge of gas in the tube. This discharge generates ultraviolet light that is transformed into visible

More information

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires l d a l POWERSTAR HQI -T 250 400 W Metal halide lamps with quartz technology for enclosed luminaires d a 1 2 GTIN (EAN) HQI-T 250 W/D PRO 4008321677846 250 19000 E40 46 226 150 A 12 1 HQI-T 250 W/N/SI

More information

GE Ballast HID Electromagnetic nomenclature

GE Ballast HID Electromagnetic nomenclature Distributor Ballast Kits GE stocks a comprehensive inventory of quad and 5-tap HID voltage ballast kits. The kits contain the appropriate core and coil, capacitor, ignitor (where required), mounting bracket,

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming S HINE V ENTURE L IGHTING S LED LAMPS Quality retrofit LED lighting products from a leader in the lighting industry Full range dimming Longer life and up to 90% energy savings Long product life and improved

More information

Details and specification for 30 W solar powered LED street lights.

Details and specification for 30 W solar powered LED street lights. Details and specification for 30 W solar powered LED street lights. 2 P a ge Solar LED Lighting System A Solar LED Lighting System is a solar Photovoltaic System designed for outdoor application especially

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

USER MANUAL DOUBLE ENDED LIGHTING SYSTEMS (ALL MODELS) OPEN, ENCLOSED AND SUPER DEEP SYSTEMS

USER MANUAL DOUBLE ENDED LIGHTING SYSTEMS (ALL MODELS) OPEN, ENCLOSED AND SUPER DEEP SYSTEMS USER MANUAL DOUBLE ENDED LIGHTING SYSTEMS (ALL MODELS) OPEN, ENCLOSED AND SUPER DEEP SYSTEMS GENERAL OVERVIEW Thank you for purchasing the Phantom Double-Ended Lighting System. Setup is the same for each

More information

Common to almost all eco-friendly lighting.

Common to almost all eco-friendly lighting. A series on topics of relevance and advances from the Technical Centre, Deki Electronics Ltd, India February 2012 Common to almost all eco-friendly lighting. RoHS compliant film capacitors from Deki. www.dekielectronics.com

More information

APPENDIX B: LISTS OF APPROVED MATERIALS

APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS APPENDIX B: LISTS OF APPROVED MATERIALS B1 Street Lighting MAY 2016 APPENDIX B1 STREETLIGHTING MATERIAL LIST 1.0 LIGHTING 1.1 Electrical Handholes CSA Precast concrete

More information

The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the

The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the COBRAHEAD The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the luminaires The Induction in this Cobrahead Series operate Series well can in cold be temperatures

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812 Type No. Catalog No. Job. Name WL Series APPLICATIONS Applications include low ceiling applications, light industrial manufacturing facilities, offices, lobbies, conference rooms, food processing plants,

More information

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

MUST HAVES. in Quality lighting trusted by sparkies all over the globe. 7 MUST HAVES in 2017 Light is confidence 7 MUST HAVES for 2017 Quality lighting trusted by sparkies all over the globe. 7 MUST HAVES for 2017 Check out the 7 MUST HAVES for 2017. We have chosen 7 of our

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in INDUCTION FIXTURES INDUCTION OVERVIEW INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in existence with many years of positive field test results and which has recently

More information

Transforming Energy.. For Advanced Technology

Transforming Energy.. For Advanced Technology Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial

More information

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle LED HIGH BAY 80W FEATURES LED replacement for 250W Metal Halide Lamp Energy saving up to 68% than conventional lighting 3 years standard warranty Ultra light and compact lamp Flicker free Ultraviolet free,

More information

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01 Page LED Outdoor Commercial Lighting Venus LED Bulkhead...1-2 Vesta LED Bulkhead...3-4 Jupiter LED Bulkhead...5-6 Cube LED Bulkhead...7-8 LED Up-Down

More information

Central Battery Systems

Central Battery Systems Central battery system based emergency lighting is ideal for medium to large installations. For projects where central control and testing is desirable, a central battery system is a viable and cost effective

More information

Protected

Protected 6.1 Protected 6.1 6.2 6.2 PPF1 PPF3 PPF4 PPF13 6.3 6.3 6.4 6.4 PPF11 PPF6 PPF5 PPF7 6.5 6.5 6.6 6.6 PPF8 PPF9 PPF10 PPF12 6.7 6.7 PPF14 1.9 1.9 1.10 1.10 1.11 1.11 1.12 1.10 Namibia- Pg 6 PPF1 Pluto vapourproof

More information

The Denver Pole Mount luminaire with its attractive

The Denver Pole Mount luminaire with its attractive 1.3 denver pole applications Landscaped areas Car parks Amenity areas Retail parks Entrance roads Pedestrian areas The Denver Pole Mount luminaire with its attractive contemporary styling and exceptional

More information

Sistema Easy. Sistema Easy MH page 115. ø 212. Sistema Easy FL page 117. Sistema Easy FL page 117. ø 212. ø 250. design Maurizio Varratta

Sistema Easy. Sistema Easy MH page 115. ø 212. Sistema Easy FL page 117. Sistema Easy FL page 117. ø 212. ø 250. design Maurizio Varratta Sistema Easy design Maurizio Varratta Sistema Easy MH page 115 General light Wall Washer Sistema Easy FL page 117 Sistema Easy FL page 117 General light General light ø 250 114 products.iguzzini.com/sistema_easy_line

More information

S/H/MPC SERIES S/H/MPC SERIES. City Beautification. City Beautification. City Beautification. Technical Data

S/H/MPC SERIES S/H/MPC SERIES. City Beautification. City Beautification. City Beautification. Technical Data City beautification It s about improving the quality of life, the appearance, feeling and atmosphere of where people live, work and play. It s about introducing aesthetics in the lighting of our streets

More information

ArenaVision MVF403 world-class performance

ArenaVision MVF403 world-class performance Lighting ArenaVision MVF403 world-class performance ArenaVision MVF403 ArenaVision MVF403 takes sports floodlighting to the highest level, offering very high light output, optical efficiency, ease of installation,

More information

Amount (Rs) 1.5 sq. mm ISI marked, FR

Amount (Rs) 1.5 sq. mm ISI marked, FR BILL OF QUANTITY FOR ELECTRICAL WORK AT ESI REGIONAL OFFICE, STAFF QUARTERS, SEC-16 AND ASSOCIATED BRANCH OFFICE AND DISPENSARY. Part-II Sr. no SOR No. Details of Items Unit Quantity Rate (Rs) Amount (Rs)

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

BRUDA. Removable control gear plate. Computer aided design reflector. Single piece high-pressure diecast aluminium housing.

BRUDA. Removable control gear plate. Computer aided design reflector. Single piece high-pressure diecast aluminium housing. , designed specifically to allow for tool free maintenance is a single piece high pressure die cast area light. High output computer designed reflector with a removable control gear plate. is equipped

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information