GE Ballast HID Electromagnetic nomenclature

Size: px
Start display at page:

Download "GE Ballast HID Electromagnetic nomenclature"

Transcription

1 Distributor Ballast Kits GE stocks a comprehensive inventory of quad and 5-tap HID voltage ballast kits. The kits contain the appropriate core and coil, capacitor, ignitor (where required), mounting bracket, mounting hardware and instructions to allow the stocking distributor to meet the needs of their customer while minimizing their investment in component parts. The quad ballast kit has color-coded leads to identify voltages and operates at 120/208/240/277. The 5-tap HID ballast kits also include 480-volt applications and are listed as ML5, though GE also offers single-voltage kits for 480-volt with 120-volt taps for stand-by lighting. Also available for metal halide and high pressure sodium applications is the 5-tap ballast-lamp replacement kit listed as -55. This easy-tocarry, convenient, all-in-one kit, ensures ballast-lamp compatibility by including the lamp as well. s and capacitors, where required, are included with the quad and 5-tap ballast kits. Capacitors Most GE capacitors and ignitors are sold in ballast kits that come pre-wired and reduce labor cost. Capacitors and ignitors are also sold separately. Power factor capacitors are used to reduce the negative effects that inductive devices (HID ballast) have on power factor ratings. GE sells a complete line of capacitors that must be properly matched to the lamp and HID ballast. GE capacitors have bleed-in resistors and use biodegradable, nontoxic (no PCBs) dielectric fluid. GE il-filled Capacitors are packaged in metal cases (up to 520V ratings). All GE capacitors are designed for 60,000 hours of continuous life. Dry Capacitors do not contain oil and are manufactured with plastic casing. Dry casings are rated up 100 C maximum. Dry capacitors are designed and rated for AC voltages below at 50 or 60Hz. s s are also sold in individual cartons for replacement needs. s supply a high voltage pulse to ionize the gas creating the glow discharge. nce the lamp is started the ignitor stops providing the pulse. s are designed to last thousand of hours; however, if the lamp fails or the socket is empty, the ignitor will continue to pulse. The lamps should be replaced or the fixture turned off to prevent premature failure of the ignitor. Standard ignitors are supplied with metal halide ballast 150 watts or less, pulse start metal halide and high-pressure sodium ballast. There are several different ignitors that meet the needs of many GE lamp and ballast combinations. The appropriate ignitor is listed in the catalog under the ballast specifications. Potted Core and Coil Ballast GE potted core and coil ballasts are designed for applications requiring quieter or cooler operation than provided by standard coil and coil ballast. The potting material is sand-filled polyester which provides excellent sound-deadening and heat-transfer qualities. F-Can Ballast GE F-Can ballast is recommended for indoor applications and where ballast noise must be minimized. F-Can ballast are encased in fluorescent ballast-type cans and potted with asphalt insulating materials to minimize noise. Ballast Date and Temperature s Date s GE HID core and coil ballast manufacturing date codes are located on the top end of the core. They are printed in white and indicate year, month manufactured, and order the ballast was manufactured in the month. A code of would indicate manufacture date of 07 (year 2007), 01 (month of January), and would be the manufacturing sequence. UL Bench Top Temperature To help with UL inspection, the UL Bench top code is listed on the GE label on the core and coil ballast as 1029X. X is the temperature code and represented by the following temperature classifications: A, B, C, D, E and F. UL Bench Top Letter A B C D E F Temperature Range for Class H (180C) Ballast Less than 75C 75C < 80C 80C < 85C 85C < 90C 90C < 95C 95C < 100C GE Ballast HID Electromagnetic nomenclature G E M M L T A C 5 D - 5 GE Ballast M = EM Ballast GEH = Mercury GEM = Metal Halide GEP = Pulse Start Metal Halide GES = HPS Watts: 1000W Voltage: MLT = Quad ML5 = Multi 5 T = Trivolt 48T = 480/120 tap 277 = 277V 230 = 230V Type: : R = Reactor A = I = CWI = Iso Reg L = High Reactance/lag M = Mag Lag C = Core & Coil Cu A = Core & Coil Aluminum F = F Can W = Weatherproof E = Encased/Potted I = Indoor Encased Frame Size: E = E & I 3 = 3x4 4 = 4-3/4 5 = 5-3/4 X = non C & C Capacitor: D = Dry Film = il Film Pack Type: -5 = Dist. Kit -55 = Dist. Kit & -1 = C & C -1B = C & C w/welded bracket -60 = C & C no capacitor -61 = C & C w/ welded bracket, no cap 18-4 See page E-1 for warranty information.

2 HID Electronic and Electromagnetic Ballasts For W HID s GEM400MLTAA W MH Quad A1 C&C ANSI s Voltage 120/208/240/ Mfd GECAP-24/- Voltage (MIN) 450 Distributor Kit W Quartz 360W Quartz System Wattage (W) Nominal Current 4.0 A 2.30 A 2.00 A 1.75 A Ballast Factor Ballast Efficiency Factor Max Input Current 4.0 A 2.30 A 2.00 A 1.75 A Starting Current 3.80 A 3.80 A 3.80 A 3.80 A pen Circuit Voltage 300V 300V 300V 300V Drop ut Voltage 580V 580V 580V 580V Power Factor (>=)% Starting Temp ( F/ C) -22 / / / / -30 Fuse Rating UL Bench Top Rise D or A D or A D or A D or A c Quad ballast (120, 208, 240, 277) Wiring diagram HID W-(C) see example on page Case dimensions Ref Drawing PC2 see page in (117 mm) A 2.17 B lbs 4.25 in x 4.75 in GEM40048TAA4 5/ W MH 480 ANSI s Voltage Mfd GECAP-24/- Voltage (MIN) 400 Distributor Kit W Quartz 360W Quartz 480 System Wattage (W) 460 Nominal Current 1.00 A Ballast Factor 1 Ballast Efficiency Factor 0.90 Max Input Current 1.00 A Starting Current 3.80 A pen Circuit Voltage 295V Drop ut Voltage 560V Power Factor (>=)% 90. Starting Temp ( F/ C) -22 / -30 Fuse Rating 2 UL Bench Top Rise D or A c Wiring diagram HID W-(J) see example on page Case dimensions Ref Drawing PC2 see page in (117 mm) A 2.17 B lbs 4.25 in x 4.75 in See page E-1 for warranty information.

3 HID Electronic and Electromagnetic Ballasts For W HID s GEM1000MLTAA5-5/ W MH Quad ANSI s Voltage 120/208/240/ Mfd GECAP-24/- Voltage (MIN) 540 Distributor Kit W Quartz System Wattage (W) 1,050 1,050 1,050 1,050 Nominal Current 8.80 A 5.10 A 4.40 A 3.80 A Ballast Factor Ballast Efficiency Factor Max Input Current 8.80 A 5.10 A 4.40 A 3.80 A Starting Current 5.60 A 5.60 A 5.60 A 5.60 A pen Circuit Voltage 415V 415V 415V 415V Drop ut Voltage 830V 830V 830V 830V Power Factor (>=)% Starting Temp ( F/ C) -22 / / / / -30 Fuse Rating UL Bench Top Rise D or A D or A D or A D or A c Quad ballast (120, 208, 240, 277) Wiring diagram HID W-(C) see example on page Case dimensions Ref Drawing PC3 see page in (197 mm) 2.75 in (70 mm) 6.1 in (155 mm) A 3.10 B lbs 4.25 in x 6.00 in GEM1000TRIAC W Tri Tap (120/277/347V) ANSI s Voltage 120/277/347 Insulation Class Class N, 200C 24 Mfd GECAP-24/- Voltage (MIN) Hz/ Distributor Kit W MH System Wattage (W) Nominal Current 9.5 A 4.0 A 3.3 A Ballast Factor Ballast Efficiency Factor Max Input Current 10.5 A 4.4 A 3.6 A Starting Current 5.70 A 5.70 A 5.70 A pen Circuit Voltage 305V 305V 305V Drop ut Voltage 72V 166V 208V Power Factor (>=)% Starting Temp ( F/ C) -20 / / / -29 Fuse Rating UL Bench Top Rise E E E c Tri Tap ballast (120/277/347) Wiring diagram HID W-(M) see example on page Case dimensions Ref Drawing PC3 see page A 2.96 in (75 mm) B 4.92 in (125 mm) 24.1 lbs 5.37 in (136 mm) 4.25 in (108 mm) x 6.00 in (152 mm) See page E-1 for warranty information.

4 HID Accessories and Replacement Capacitors HID Electronic and Electromagnetic Ballasts gelighting.com Ballasts Type Use with ANSI Types Watts New GE Description M GEM250ML5AC w MH M 58 or H 37 5-Tap (120/208/240/277/) Kit Capacitor Description Cap. uf UL Replacement Capacitor Desc. Actual electrial voltage of capacitor both ends riginal Replacement GECAP-15/ MF N/A T8 Instant Start M GEM250ML5AC w MH M 58 or H 37 5-Tap (120/208/240/277/) M GEM250MLTAC w MH M 58 or H 37 Quad M GEM250TRIAC w MH M 58 or H 37 Quad SC-TC 1-400w 120/277 Enclosed & Potted F-can GECAP-15/ MF N/A GECAP-15/ MF N/A GECAP-15/- 370V MF N/A T8 Programmed Start SCTC000I 1-400w 120/277 Enclosed & Potted GEM40048TAC w MH M 59 or H GEM400ML5AA w MH or H33 5-Tap (120/208/240/277/) Al C&C GEM400MLTAA w MH M 59 or H 33 Quad Al C&C GEM400TRIAC w MH M 59 or H 33 Quad Al C&C GEM100048TAC w MH M 47 or H GEM1000ML5AA w MH M 47 or H 36 5-Tap (120/208/240/277/) GEM1000MLTAA w MH M 47 or H 36 Quad GECAP-24/ MF N/A GECAP-24/ MF N/A GECAP-24/ MF N/A GECAP-24/- 370V MF N/A GECAP-24/ MF N/A GECAP-24/ MF N/A GECAP-24/ MF N/A T8 Dimming T5 Electronic Programmed Start GEM1000TRIAC w MH M 47 or H 36 Quad 540V M GEM150048TAC w MH M MFD 525V M GEM1500MLTAC w MH M 48 Quad 32MFD 525V GECAP-24/ MF N/A GECAP-32/525V- GECAP-32/525V- N/A GECAP-32/525V- GECAP-32/525V- N/A T12 Electronic & High utput M GEMH20-MLF W M V Electronic HID Pulse Start M GEMH39-MSF W M V Electronic HID C GEMH50-MSF W M110 M/C V M GEMH50-MSF W M110 M/C V M GEMH50-MSF W M110 M/C V C GEMH70-MSF W M98 M/C V C GEMH70-SLJ-MV 1-70W M98 M/C V-277V M GEMH70-MSF W M98 M/C V M GEMH70-MSF W M98 M/C V Magnetic Sign M GEMH70-MSF W M98 M/C V M GEMH70-SLJ-MV 1-70W M98 M/C V-277V M GEMH70-MSF W M98 M/C V Compact Fluorescent M GEMH70-SLJ-MV 1-70W M98 M/C V-277V C GEMH100-SLJ-MV 1-100W M90 M/C V- 277V M GEMH100-SLJ-MV 1-100W M90 M/C V- 277V See page E-1 for warranty information HID Electronic & Electromagnetic

5 HID Accessories and Replacement Capacitors HID Electronic and Electromagnetic Ballasts gelighting.com Ballasts Type High Pressure Sodium Use with ANSI Types Watts See page E-1 for warranty information. New GE Description M GEP320TRIAC w PS M132 or M154 TRI- Voltage CMH GE-MH-250- CMH GEMH250- M GE-MH-250- M GEMH250- Kit Capacitor Description Cap. uf 21MFD M GEP350277RCE w PS M Reactor 22.5MFD M GEP350MLTAC w PS M131 Quad M GEP350TRIAC w PS M131 Quad CMH GE-MH-250- CMH GEMH250- M GE-MH-250- M GEMH250- UL Replacement Capacitor Desc. Actual electrial voltage of capacitor both ends riginal Replacement GECAP-21/- GECAP-21/- 22.5MFD 22MFD M GEP40048TAC w PS M135 or M M GEP400MLTAC w PS M135 or M155 Quad M GEP400TRIAC w PS M135 or M155 Quad M GE-MH-250- M GEMH250- M GEP400MLTAC w PS M135 or M155 Quad GECAP-225/- GECAP-22.5/ GECAP-225/- GECAP-22.5/ V GECAP-22.5/- 26MFD GECAP-24/ MF GECAP-24/ MF GECAP-26/525V- 360V MF M GEP40048TAC w PS M135 or M M GEP75048TAC w PS M MFD M GEP750MLTAC w PS M149 Quad M GEP750TRIAC w PS M149 Quad M GEP1000ML5AC w PS M141 5-Tap (120/208/240/277/) M GEP1000MLTAC w PS M141 Quad M GEP1000TRIAC w PS M141 Quad S GES50MLTLC3D w HPS S68 Quad S CTC000I 1-70w S62 120/277 E & P F-can built-in starter 28MFD 28MFD 25MFD 5MFD 280V GECAP-24/ MF GECAP-24/ MF GECAP-28/- GECAP-28/ MH750-1B GECAP-28/- GECAP-28/ MH750-1B GECAP-28/- 405V GECAP-28/ MH750-1B GECAP-24/ MF HPS1000-4B GECAP-24/ MF HPS1000-4B V MF HPS1000-4B GECAP-5/300V-D GECAP-5/300V-D HPS150-3A S U000I 1-70w S Reactor-NPF S GES50TRILC w HPS S62 Quad 5MFD 300V S GES7048TLC3D w HPS S62 7MFD 300V V GECAP-7/300V-D HPS150-3A GECAP-7/300V-D GECAP-7/300V-D HPS150-3A T8 Instant Start T8 Programmed Start T8 Dimming T5 Electronic Programmed Start T12 Electronic & High utput Magnetic Sign Compact Fluorescent HID Electronic & Electromagnetic

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

GECAP24400V0 Capacitor For 400W MH BLST

GECAP24400V0 Capacitor For 400W MH BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 GECAP24400V0 Capacitor For 400W MH BLST G.E. Lighting (blst) Catalog Number Manufacturer Description per unit Product

More information

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly

More information

GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt

GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt G.E. Lighting (blst) Catalog Number Manufacturer Description per

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

ELECTROMAGNETIC HID BALLASTS

ELECTROMAGNETIC HID BALLASTS ELECTROMGNETIC HID BLLSTS CONTENTS 234 235 239 242 245 246 247 249 How to Read a Table Pulse Start Metal Halide Ballasts Standard Metal Halide Ballasts High Pressure Sodium Ballasts Guide Guide Cross Reference

More information

MAGNETIC HID BALLASTS

MAGNETIC HID BALLASTS Philips dvance HID ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, HID lamps are

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

71A D 400W 277V MH Ballast

71A D 400W 277V MH Ballast 3804 South Street 75964-7263, TX acogdoches Phone: 936-569-7941 Fax: 936-560-4685 716031500 400W 277V MH allast Philips dvance Catalog umber 716031500 Manufacturer Philips dvance escription allast, Contents

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

MMagneTek ELECI RONIC FLUORESCENT BALLAST R'!AiB Tria d ' loiiiiiitrlllll-..lhod Now'lodloologv. Univefsal Voltage.

MMagneTek ELECI RONIC FLUORESCENT BALLAST R'!AiB Tria d ' loiiiiiitrlllll-..lhod Now'lodloologv. Univefsal Voltage. ELECI RONIC FLUORESCENT BALLA MATRIX Lamp Type "R" educed "H" armonic (THO< 20%) Low Profile Oly Voltage Instant Start Standard can Programmed Rapid Instant Start Start AccuStartTM Univefsal Voltage Low

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

ER D IN K F IC U ST Q LLA BA

ER D IN K F IC U ST Q LLA BA BALLAST QUICK FINDER BALLAST What is a ballast? A ballast is an integral component of most modern lighting systems. It is primarily designed to perform three critical tasks: Deliver the proper voltage

More information

CORE AND COIL, DRY CAPACITOR, BRACKET, IGNITOR, MOUNTING HARDWARE 3-15/16 INCH L X 2.13 INCH W X 2-3/16 INCH H

CORE AND COIL, DRY CAPACITOR, BRACKET, IGNITOR, MOUNTING HARDWARE 3-15/16 INCH L X 2.13 INCH W X 2-3/16 INCH H 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 llenwatson@elliottelectric.com LU70MULTIKIT Hid Ballast Sylvania-Ledvance Catalog Number Manufacturer Description Weight

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

Lighting Tables for New Equipment 1/1/2018

Lighting Tables for New Equipment 1/1/2018 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00

More information

Lighting Tables for New Equipment 2/24/2015

Lighting Tables for New Equipment 2/24/2015 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Lighting Tables for New Equipment 3/9/2016

Lighting Tables for New Equipment 3/9/2016 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION

More information

SXPJ SERIES S X azz.com/rigalite

SXPJ SERIES S X azz.com/rigalite SXPJ SERIES HID Lighting & Compact for Explosion Fluorescent Proof, Lighting Hazardous for and Hazardous Hostile Locations and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division

More information

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor Mercmaster III HID 50-250 Watt Luminaires Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing and other areas where

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS Overview Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID ballasts bring significant performance improvements to HID lighting systems: Higher efficiency Greater

More information

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation.

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation. Prepared by the Product Administration Group Technical Services Dept. Advance Transformer Co. The High Intensity Discharge (HID) lighting industry has experienced tremendous growth in terms of size, as

More information

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations SXPJ SERIES HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations S X PJ Class I, Division 1, Group C & D Class II, Division 1, Groups E, F & G Class III Zone 1, Groups IIA & IIB Factory

More information

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) 4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D) Cl. I, Div. 1 Groups B (GB suffix),c,d (with suffix GB), IIB IIA Paint Spray (100W max) Application: Hazard Gard luminaires are

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Constant wattage for high intensity discharge (HID) lamps

Constant wattage for high intensity discharge (HID) lamps onstant wattage for high intensity discharge (HID) lamps Index page Introduction 143 onstant wattage control equipment 144 onstant wattage application 145 onstant wattage mercury vapour and metal halide

More information

TORNADOTM BOLLARD PATENTS PENDING

TORNADOTM BOLLARD PATENTS PENDING TORNADOTM BOLLARD PATENTS PENDING Day Tornado Bollard Unlike any bollard available in today s specification pallet, Tornado offers a new form and character for pedestrian scale lighting. Tornado adds an

More information

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2S40SC35I 2 F34T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

Lighting: Explosionproof Area HID. Applications. Standard Materials

Lighting: Explosionproof Area HID. Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent S A F Class I, Division 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844

More information

VEL2P75S35I 2-F96T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description

More information

Applications. Standard Materials

Applications. Standard Materials Code Master Jr. HID Factory Sealed Luminaires Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 50 W, 70 W, 00 W, 75 W PSMH. 75 W MH V. Medium Base. For Use with Threaded Metal Conduit. Class I, Division

More information

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 Integrally Ballasted. 50 W, 70 W, 00 W, 50 W HPS; 75 W PSMH. 75 W MH. Medium Base. For Use with Threaded Metal Conduit. Applications For use in chemical and petrochemical plants, such as manufacturers

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

HID Lamps Ballasts Magnetic Ballasts Electronic Ballasts Electronic Ballasts for Low Wattage Metal Halide

HID Lamps Ballasts Magnetic Ballasts Electronic Ballasts Electronic Ballasts for Low Wattage Metal Halide Introduction This guide is written to help the reader understand, evaluate and specify HID ballasts, both magnetic and electronic. It starts with lamp and ballast basics and concludes with an explanation

More information

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options Code Master 2 HID Factory Sealed Floodlights NEC: Class 1, Division 1 and 2, Groups C, D Marine Type Electric Fixtures Outside Type (Salt Water) CEC: V Class I, Division 1 and 2, Groups B, C, D Class II,

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

Standard Grade 14 Inch Reflector. Ordering Information

Standard Grade 14 Inch Reflector. Ordering Information Job Type Dimensions Specifications B A NRTL/C C Damp Location D E Slick- On Quick- On F A B C D E F 9-1/2" 2" 9-1/2" 20-22/32 24-27/32" 9-7/16" 14-1/4" 241 mm 51 mm 241 mm 536-631 mm 240 mm 362 mm 9-1/2"

More information

Installation Instructions

Installation Instructions Bi-Level Control Module For fixtures with CWA transformers and non-encased capacitors, using Metal Halide, Metal Halide (Pulse Start) or High Pressure Sodium lamps between 75-000W Model#s: -250H -400H

More information

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options Applications UL Listed for Outside Type (Salt Water). Ideal in Class I, Division 1 and 2 installations in refineries, in pipeline transportation facilities, at drilling rigs and in production facilities

More information

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480) Del Mar Corrosion resistant, Weather Tight Unit fabricated from spun Aluminum.080 Thick, Full Gasket Keeps out insects and Water. Lens & Removable Door Assembly: Hinged Door Assembly Formed from One Piece

More information

H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS

H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS Super Pulse Start Long Life (SPL) Lamps 41 HID METAL H ALIDE L AMPS Standard and Pulse Start Lamps 50 32100 MP 50W/U/UVS/PS M110/0 12 52312 MH 50W/U/PS

More information

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations. A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires Class I, Division 1 and 2, Groups C, D Class I, Division 1 and 2, Groups B, C, D Applications Ideal for use in chemical and petrochemical plants, such as manufacturers

More information

H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS

H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS H IGH I NTENSITY D ISCHARGE L IGHTING S OLUTIONS Super Pulse Start Long Life (SPL) Lamps 33 HID METAL H ALIDE L AMPS Standard and Pulse Start Lamps 50 32100 MP 50W/U/UVS/PS M110/0 12 52312 MH 50W/U/PS

More information

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle LED HIGH BAY 80W FEATURES LED replacement for 250W Metal Halide Lamp Energy saving up to 68% than conventional lighting 3 years standard warranty Ultra light and compact lamp Flicker free Ultraviolet free,

More information

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear W, W, W, 1W, 2W, W & W DATA SHEE T Lucalox TM XO Elliptical Diffuse W, W, W, 1W, 2W & W Product information

More information

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert

More information

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Bob Trate - CPMR Philips/Advance Ballasts April 20, 2010 Fluorescent Ballast Overview There are several generations and design

More information

Laredo Decorative Wallpack Family

Laredo Decorative Wallpack Family Outdoor Lighting Laredo Decorative Wallpack Family NEW Selections Full Cutoff IDA Compliant Laredo Application Guide Compact LCC 6-1ft mounting height The Laredo Family meets the Strictest Lighting Codes

More information

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109 s s ACS Small Acorn 109 ACL Large Acorn 109 AC3, AC5 Large Type 3 or 5 Acorn 109 BKS Small Buckeye 111 BKL Large Buckeye 111 BK3, BK5 Large Type 3 or 5 Buckeye 111 Small Chestnut 113 Large Chestnut 113

More information

RELB2S40N35I (2)F40T12 120V Ele BLST

RELB2S40N35I (2)F40T12 120V Ele BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RELB2S40N35I (2)F40T12 120V Ele BLST Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category

More information

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast IZT2S32SC 2 Lamp 32/T8 immable Ballast Philips Advance Catalog Number Manufacturer escription Weight per unit Product Category IZT2S32SC Philips Advance Electronic Ballast, High Frequency; Programmed Start;

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances Code Master 2 HID Factory Sealed Luminaires NEC: Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Marine Type Electric Fixtures Outside Type (Salt Water) Class I, Division

More information

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances Integrally Ballasted. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Applications Ideal for use in chemical and petrochemical plants, such as

More information

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC

More information

Table of Contents T8 Instant Start Ballasts

Table of Contents T8 Instant Start Ballasts Table of Contents T8 Instant Start Ballasts gelighting.com Ballasts Understanding T8 Fluorescent Ballasts...10-2 Understanding Fluorescent Systems...10-3 Fluorescent Ballast Application Notes...10-5 UltraMax

More information

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT MHD2/MHDO SERIES Marine Heavy Duty Outdoor Non-Metallic Fluorescent Non-metallic, glass reinforced polyester housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR

LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera MH HID LED Gen 2, a LED plug-and-play replacement, causes the ballast to

More information

GE Lighting DATA SHEET. Product information. Features. Applications

GE Lighting DATA SHEET. Product information. Features. Applications GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 5W, 7W, W, 15W, 25W, 4W & 6W Lucalox TM XO Elliptical Diffuse 5W, 7W, W, 15W, 25W & 4W DATA SHEET

More information

UL AND CODE COMPLIANCE

UL AND CODE COMPLIANCE BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency

More information

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1 Job Type Dimensions Specifications B A C NRTL/C Damp Location D Slick-On Quick-On E A B C D E 9-1/2" 2" 9-1/2" 26-11/16" 23-1/8" 241 mm 51 mm 241 mm 678 mm 587 mm 9-1/2" 1-1/8" 8-5/8" 25-13/16" 23-1/8"

More information

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by: 1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps

More information

Perimaliter Wallpacks

Perimaliter Wallpacks ENERGY SAVING Outdoor Lighting Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design

More information

Arcstream Double Ended

Arcstream Double Ended GE Lighting Arcstream Double Ended Metal Halide lamps 7W, 15W and 25W Product Information High brightness, high quality white and coloured light with good colour rendition, excellent colour consistency

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID BALLASTS Precision Power. Perfect Light. Ballasts, Drivers, Transformers & Lamps For All Lighting Applications Electronic HID Ballasts Hatch Electronic HID ballasts have been designed from

More information

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent MHD2/MHDO SERIES Marine Heavy Duty Non-Metallic Fluorescent Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III Zone 2, Groups IIA, IIB & IIC UL 844 Hazardous Locations

More information

N2MV Series W Non-metallic

N2MV Series W Non-metallic N2MV Series 50-175W Non-metallic Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations, R, 4, 4X; IP56 L Applications: N2MV series Champ

More information

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting High Bay Lighting Solutions WORKING INSTANTLY, QUIETLY FOR REMARKABLE ENERGY SAVINGS Universal Lighting Technologies

More information

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations 1-24 Applications UL listed for marine type electric fixtures--outside type (salt water). Ideal in Class I, Div. 1 and 2 installations in refineries, pipeline transportation facilities; at drilling rigs

More information

Overall Dimensions. Specifications

Overall Dimensions. Specifications Overall Dimensions EFX B EFX VM Vertical Mount C 13 housing (70-400W) 19 housing (450-1000W) E D H B C D E 13.3 16.8 16.2 7.0 9.8 (33.78cm) (42.67cm) (41.15cm) (17.78cm) (24.89cm) F G H I J 22.2 11.3 6.3

More information

Laredo - Decorative Wallpack Family

Laredo - Decorative Wallpack Family Outdoor Lighting Laredo - Decorative Wallpack Family Full Cutoff New Laredo Application Guide Compact LCC 6-1ft mounting height The Laredo Family meets the strictest lighting codes Full Cutoff Star View

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID BALLASTS Precision. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Electronic HID Ballasts Electronic HID ballasts have been designed from

More information

RPX. Specular louver Semispecular RSX. louver. FUS GLR fuse for each ballast IDS

RPX. Specular louver Semispecular RSX. louver. FUS GLR fuse for each ballast IDS Photometric Drawing for (1) 28W T5 Lamp CATALOG NUMBER FIXTURE OVERALL ROW LENGTH MAX SECTION LENGTH SHIELDING LAMPING (SEE CROSS SECTION) VOLTAGE OPTIONS* EF1P Enform 1 Pendant # # must be specified in

More information

Perimaliter Wallpacks

Perimaliter Wallpacks Perimaliter Wallpacks Perimaliter III PVL3 / PGM3 Perimaliter II PGL Solutions for Perimeter/Area Lighting Perimaliter Wallpacks The Perimaliter wallpack has been the design leader in refractor wallpacks

More information

TRUET5 EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE) t all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TRUET5 EXT (DIMMABLE) www.trulygreensolutions.com

More information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING) INSTALLATION INSTRUCTIONS SECURITY HID Document: CI308X61R0 Date: 2013-4-18 Created By: TMT DCR#: 2013-138 FIGURE 1 FIGURE 2 CAUTIONS: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety

More information

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN3P32SC35I 3-F32T8 120/277V Electronic Philips Advance Manufacturer Description Weight per unit Product Category Features

More information

AC Line / Load Reactors

AC Line / Load Reactors AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100

More information

LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR

LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera Susan Lamp, a LED plug-and-play replacement, causes the ballast to have

More information

PGL350P W PS Wallpack

PGL350P W PS Wallpack 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PGL350P1281 350W PS Wallpack Hubbell Lighting, Inc. Catalog Number Manufacturer Description Weight per unit Product Category

More information

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series Low brightness and uplighting combine to create a pleasing visual environment Softbay Series Keene MAKES LIGHT WORK Softbay is a durable performer in light-to-moderate industrial environments and an enduring

More information

RZT2S54 Electr DMMG Ballast

RZT2S54 Electr DMMG Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RZT2S54 Electr DMMG Ballast Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large PRODUCT SPECIFICATIONS PENDANT: Extruded aluminum body with silver powder coat finish. Clear prismatic acrylic diffuser dome provides soft self-illumination. MOUNTING: 4 solid square fixture hanger attached

More information

Aerovox Corp. Capacitors for HID Lighting Applications. Catalog HID-cap 2004-R0

Aerovox Corp. Capacitors for HID Lighting Applications. Catalog HID-cap 2004-R0 Aerovox Corp. Capacitors for HID Lighting Applications Catalog HID-cap 2004-R0 Table of Contents Introduction...3 Quality Assurance...3 Applications...4 Agency Listings...4 of Aerovox Capacitors:...4 Safety

More information

Control gear/ballast. damage to filament of FTL if used in multi switching (>3 cycles/ day) installation. Lamp life is reduced.

Control gear/ballast. damage to filament of FTL if used in multi switching (>3 cycles/ day) installation. Lamp life is reduced. Control gear/ballast A high intensity discharge lamp generally shows peculiar negative resistance characteristic, while striking the lamp it exhibits a very high impedance thus drawing no current. As starter

More information

Technical Application Guide for UP-SHINE LED Tube Light

Technical Application Guide for UP-SHINE LED Tube Light Technical Application Guide for UP-SHINE LED Tube Light UP-T836W24-R Introduction Up-shine AL+PC LED Tube light adopts LM- 8 2835 SMD LED with high brightness and slight light decay..8mm thickness AL663

More information

Technical Application Guide for UP-SHINE LED Tube Light

Technical Application Guide for UP-SHINE LED Tube Light Technical Application Guide for UP-SHINE LED Tube Light UP-T824W15-O Introduction LED Glass Tube is the most practical and economical energy saving design compared to aluminum & PC tube or complete plastic

More information

ConstantColor CMH Supermini Ultra

ConstantColor CMH Supermini Ultra GE Lighting ConstantColor CMH Supermini Ultra New Generation of Single Ended Ceramic Metal Halide Lamps 35W DATA SHEET Product information GE s low watt CMH lamps have opened new possibilities for lighting

More information

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions ! CAUTION All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards. Improper installation may result in serious injury

More information

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4 (387mm) 15 3 /4 Vektor Project: Series Reflector Mounting Lamping Finish Voltage VE Vektor R Type II Aluminum Reflector Single R5 Type V Aluminum Reflector Double M Single ' Arm M Double ' Arm W Wall T Single Fitter Type:

More information