Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer

Size: px
Start display at page:

Download "Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer"

Transcription

1 Bulletin, A, B, D Transformers Product Overview Transformers Bulletin A B D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer Features Single, dual, and multi-tap primary voltages Single phase EN - finger-safe protection RoHS compliant / Hz, Hz, or Hz Optional Fusing Dual/Multi-tap RoHS compliant Single phase / Hz Optional Fusing Dual/Multi-tap RoHS compliant Single phase Hz only Optional Fusing Indoor/outdoor non-ventilated enclosure Single phase Exceeds requirements of the Uniform Building (UBC) and California Title Copper windings provided for all transformers rated kva and below Aluminum windings provided for all transformers rated kva and above NEMA Type R rated enclosures / HZ or Hz Output Power VA VA VA. kva Input Voltage/ Primary Voltage Output Voltage/ Voltage Insulation V ( Hz) V V ( Hz) VA Class C ( C temp. rise) V (/ Hz) V V V (/ Hz) V V VA Class C ( C temp. rise) VA Class C ( C temp. rise) VA Class C ( C temp. rise) Class C ( C temp. rise) Certifications culus, CE culus culus UL, CSA Standards CSA C. No.., EN, UL -, - CSA C. No.., UL -, - CSA C. No.., UL -, - CSA C. No. M, UL Product Selection Page - Page - Page - Page - - Publication A-CAA-EN-P

2 Bulletin Product Overview/Catalog Number Explanation Cat. No. -B-HXJX--N Control Circuit Transformer, - pole Fuse Block with Optional Cat. No. -R Fuse Cover Cat. No. -C-BASX--N Control Circuit Transformer, Non-Fused Catalog Number Explanation Bulletin Multi-Tap Transformers VA Rating Description [VA] A B C D E F G H J K L M Bulletin Transformers VA Rating Description [VA] A B C D E F G H J K L M a a Bulletin Global Bulletin Global are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed or panel-mount primary and secondary fuse block. A dual primary and secondary fuse block is pre-wired and mounted on top of the transformer up to VA. VA Single, dual, and multi-tap primary voltages Single phase EN - finger-safe protection RoHS compliant A M N a b c d b Primary and Voltage Primary M V, V V ( Hz) M V, V V ( Hz) M V, V V, V ( Hz) M V, V, V XV ( Hz) M V, V, V V ( Hz) A BADX N a b c d b Primary and Voltage Primary HX V ( Hz) AX V ( Hz), V ( Hz) BA XV ( Hz), XV ( Hz) CX V ( Hz), V ( Hz) DX V ( Hz) JX V ( Hz) SX V ( Hz), V (Hz) JK V ( Hz), V ( Hz) Table of Contents Product Selection... - Approximate Dimensions... - Accessories... - Standards Compliance UL -, UL - EN CSA C. No.. Certifications culus Listed (File No. E; Guide No. XPTQ, XPTQ) CE Fuse Block Options Block Options Primary, Primary, Primary, Primary, N c d Factory Installed Options Description No Fusing, No Cover Fuse Block Options Block Options Primary, Primary, Primary, Primary, N c d Factory Installed Options Description No Fusing, No Cover When the primary voltage code BA is selected and a V AC secondary is desired, the secondary voltage code SX should be selected. VA rating codes G, H, or J with primary voltage over V have only culus approval. Not available for use with primary voltage code BA. VA rating codes H M are only available with no fuse block option (). Publication A-CAA-EN-P -

3 Bulletin Product Overview Selecting a Control Circuit Transformer For proper transformer selection, three characteristics of the load circuit must be determined in addition to the minimum voltage required to operate the circuit. These are total steady-state (sealed) VA, total inrush VA, and inrush load power factor. Total steady-state (sealed) VA is the volt-amperes that the transformer must deliver to the load circuit for an extended period of time the amount of current required to hold the contact in the circuit. Total inrush VA is the volt amperes that the transformer must deliver upon initial energization of the control circuit. Energization of electromagnetic devices takes milliseconds. During this inrush period, the electromagnetic control devices draw many times normal current times normal is typical. Inrush load power factor is difficult to determine without detailed vector analysis of all the load components. Such an analysis is generally not feasible. Therefore, a safe assumption is % power factor. Selection Process. Determine the total inrush VA of the control circuits from the table below. Do not neglect the current requirements of indicating lights and other devices that do not have an inrush VA but are reenergized at the same time as the other components in the circuit. Their total VA should be added to the total inrush VA.. Refer to the table below, Regulation Data Inrush VA. If the supply circuit voltage (Step ) is reasonably stable and fluctuates not more than ± %, refer to the % secondary voltage column. If it fluctuates as much as ± %, refer to the % secondary voltage column. Go down the column selected until at the inrush VA closest to, but not less than, the inrush VA of the control circuit.. Read to the far left side of the chart. The transformer s continuous nominal VA rating is now selected. The secondary voltage that will be delivered under inrush conditions will be either %, %, or % of the rated secondary voltage, depending on the column selected from the table below, Regulation Data Inrush VA. The total sealed VA of the control circuit must not exceed the nominal VA rating of the transformer selected from the table below, Typical Magnetic Motor Starter and Contactor Data Hz, Volt, -Pole.. Refer to the specification tables on the following pages to select a transformer according to the required continuous nominal VA, and primary and secondary voltage combinations. Regulation Data Inrush VA Power Factor Inrush VA at % Power Factor Adjustments Nominal Power VA Rating % % % Factor Multiply By %. %. %. %. %. %. %. %. %. %. Typical Magnetic Motor Starter and Contactor Data Hz, Volt, -Pole Contactor Bulletin NEMA Size VA Inrush VA Sealed - Publication A-CAA-EN-P

4 Bulletin Product Selection Note: Refer to page - for information on how to select a control circuit transformer. Primary V ( Hz) V INPUT OUTPUT V or V Cat. Nos. Primary V ( Hz)/V ( Hz) V ( Hz)/ V ( Hz) V/ V INPUT OUTPUT V or V/V V ( Hz)/ V ( Hz) Primary XV ( Hz) or XV ( Hz) V or V V ( Hz) or V ( Hz) V or V/V Continuous VA V ( Hz) V ( Hz) -A-HXJX--N -A-HXDX--N -A-AXJK--N -A-AXSX--N -A-BAJK--N -A-BASX--N -B-HXJX--N -B-HXDX--N -B-AXJK--N -B-AXSX--N -B-BAJK--N -B-BASX--N -C-HXJX--N -C-HXDX--N -C-AXJK--N -C-AXSX--N -C-BAJK--N -C-BASX--N -D-HXJX--N -D-HXDX--N -D-AXJK--N -D-AXSX--N -D-BAJK--N -D-BASX--N -E-HXJX--N -E-HXDX--N -E-AXJK--N -E-AXSX--N -E-BAJK--N -E-BASX--N -F-HXJX--N -F-HXDX--N -F-AXJK--N -F-AXSX--N -F-BAJK--N -F-BASX--N -G-HXJX--N -G-HXDX--N -G-AXJK--N -G-AXSX--N -G-BAJK--N -G-BASX--N -H-HXJX--N -H-HXDX--N -H-AXJK--N -H-AXSX--N -H-BAJK--N -H-BASX--N -J-HXJX--N -J-HXDX--N -J-AXJK--N -J-AXSX--N -J-BAJK--N -J-BASX--N -K-HXJX--N -K-HXDX--N -K-AXJK--N -K-AXSX--N -K-BAJK--N -K-BASX--N -L-HXDX--N -L-AXSX--N -L-BASX--N -M-HXDX--N -M-AXSX--N -M-BASX--N With -Pole Primary and -Pole Top-Mounted Fuse Block Fuses Not Included -A-HXJX--N -A-HXDX--N -A-AXJK--N -A-AXSX--N -A-BAJK--N -A-BASX--N -B-HXJX--N -B-HXDX--N -B-AXJK--N -B-AXSX--N -B-BAJK--N -B-BASX--N -C-HXJX--N -C-HXDX--N -C-AXJK--N -C-AXSX--N -C-BAJK--N -C-BASX--N -D-HXJX--N -D-HXDX--N -D-AXJK--N -D-AXSX--N -D-BAJK--N -D-BASX--N -E-HXJX--N -E-HXDX--N -E-AXJK--N -E-AXSX--N -E-BAJK--N -E-BASX--N -F-HXJX--N -F-HXDX--N -F-AXJK--N -F-AXSX--N -F-BAJK--N -F-BASX--N -G-HXJX--N -G-HXDX--N -G-AXJK--N -G-AXSX--N -G-BAJK--N -G-BASX--N Top-mounted fuse blocks are not available for transformers VA and higher. V or V V ( Hz) or V ( Hz) Publication A-CAA-EN-P -

5 Bulletin Product Selection Note: Refer to page - for information on how to select a control circuit transformer. Primary V ( Hz)/V ( Hz) V V Cat. Nos. Primary V, V, V ( Hz) V or V/V Continuous VA V ( Hz)/V ( Hz) V ( Hz)/V ( Hz) V/V ( Hz) -A-CXJK--N -A-CXSX--N -A-M--N -B-CXJK--N -B-CXSX--N -B-M--N -C-CXJK--N -C-CXSX--N -C-M--N -D-CXJK--N -D-CXSX--N -D-M--N -E-CXJK--N -E-CXSX--N -E-M--N -F-CXJK--N -F-CXSX--N -F-M--N -G-CXJK--N -G-CXSX--N -G-M--N -H-CXJK--N -H-CXSX--N -H-M--N -J-CXJK--N -J-CXSX--N -J-M--N -K-CXJK--N -K-CXSX--N -K-M--N -L-CXSX--N -L-M--N -M-CXSX--N -M-M--N With -Pole Primary and -Pole Top-Mounted Fuse Block Fuses Not Included -A-CXJK--N -A-CXSX--N -A-M--N -B-CXJK--N -B-CXSX--N -B-M--N -C-CXJK--N -C-CXSX--N -C-M--N -D-CXJK--N -D-CXSX--N -D-M--N -E-CXJK--N -E-CXSX--N -E-M--N -F-CXJK--N -F-CXSX--N -F-M--N -G-CXJK--N -G-CXSX--N -G-M--N Transformers VA with V primary do not carry the CE mark. Top-mounted fuse blocks are not available for transformers VA and higher. - Publication A-CAA-EN-P

6 Bulletin Specifications Fuse Sizing Charts Important: Select the fuse to protect the control circuit conductors in accordance with the National Electrical. Primary Fuse Sizing Chart (When Only Primary Protection is Used) Maximum Amp Rating for Current Limiting Fuses Based on Transformer Primary Voltage and the National Electrical VA V V V V V V V V V V V V V V Primary Fuse Sizing Chart (When Primary and Protection is Used) Maximum Amp Rating for Current Limiting Fuses Based on Transformer Primary Voltage and the National Electrical VA V V V V V V V V V V V V V V Fuse Sizing Chart Maximum Amp Rating for Current Limiting Fuses Based on the National Electrical VA V V V V V Publication A-CAA-EN-P -

7 Bulletin Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Transformer without Fusing VA A B C D E F G H J K -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Transformer with Fuse Holder and Covers -/ (.) -/ (.) -/ (.) Approximate Shipping Wt. lb (kg) Without Top-Mounted Fuse Block -/ (.) -/ (.) -/ (.) -Pole Primary and -Pole Top-Mounted Fuse Block -/ (.) -/ (.) -/ (.) Transformer with Fuse Holder and Covers VA A B C D E F G H J K -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Transformer without Fusing Approximate Shipping Wt. lb (kg) Without Top-Mounted Fuse Block -/ (.) -/ (.) -/ (.) -Pole Primary and -Pole Top-Mounted Fuse Block -/ (.) -/ (.) -/ (.) - Publication A-CAA-EN-P

8 Bulletin Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Transformer without Fusing VA A B C D E F G H J K -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) -/ (.) -/ (.) -/ (.) Transformer with Fuse Holder and Covers -/ (.) Approximate Shipping Wt. lb (kg) Without Top-Mounted Fuse Block -/ (.) -Pole Primary and -Pole Top-Mounted Fuse Block -/ (.) VA A B C D E F G H -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) (.) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) / (.) / (.) / (.) / (.) / (.) Transformer without Fusing / (.) / (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Publication A-CAA-EN-P Approximate Shipping Wt. lb (kg) Without Top-Mounted Fuse Block -/ (.) -/ (.) -/ (.) -/ (.) (.) -

9 Bulletin General Purpose Transformers Accessories Product Selection Fuse Block Kits For Use when Fuse Block is Not Integrated with the Transformer Cat. No. -R -Pole Fuse Block Cat. No. -R -Pole Fuse Block Cat. No. -R -Pole Fuse Block Cat. No. -R -Pole Fuse Block Cat. No. -R Fuse Cover without Fuse These control circuit fusing kits are intended to be used for control circuit transformer protection and protection of control circuits capable of delivering no more than RMS symmetrical amps, V maximum. Description Cat. No. Fuse cover per pole -R One-pole kit panel-mounted (midget fuse) -R Two-pole kit panel-mounted (two Class CC fuses) -R Two-pole kit panel-mounted (two midget fuses) -R Three-pole kit panel-mounted (one midget fuse/two Class CC fuses) -R Three-pole kit panel-mounted (three Class CC fuses) -R Single-pole kit Bulletin line controller mounted (Class CC fuses) -FR One-pole kit panel-mounted ( A Class J fuse) -R One-pole kit panel-mounted ( A Class J fuse) -R For control circuit transformers with a VA or larger rating, it is recommended that Bussmann Type FNQ-R, Ferraz-Shawmut Type ATDR, Littelfuse Type KLDR time delay fuses, or equivalent be used for primary fusing. These kits use only Class CC or Midget fuses (rated. A) such as those offered by the following manufacturers: Bussmann KTK-R Ferraz-Shawmut ATM R Littelfuse KLK Cat. No. -FR is rated for A fuse maximum. Controller mounting applies to size devices only. - Publication A-CAA-EN-P

10 Bulletin General Purpose Transformers Accessories Approximate Dimensions Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Note: Electrical clearance required to top of fuse block. Nameplate -/ (.) -/ (.) -/ (.) / (.) Two Tabs for Std. / x / (. x.) Faston Each End and Binding Head Screws ( - ) / (.) (.) / (.) Dia. Holes / (.) -/ (.) / (.) Cat. No. -R Cat. No. -R (.) Fuse Block (.) / (.) / (.) / (.) -/ (.) -/ (.) Cat. No. -R (.) / (.) Holes for No. Screws This Clip to be for Std. Fuse (Midget), not Class CC (Rejection) / (.) / (.) Two Tabs for Std. / x / (. x.) Faston ( A max.) and - Pressure Plate Screws Typ. Places Cat. No. -R Cat. No. -R -/ / -/ -/ / (.) / (.) Cat. No. -R Publication A-CAA-EN-P -

Control Circuit Transformers

Control Circuit Transformers Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit

More information

Bulletin 1497A Machine Tool Transformers

Bulletin 1497A Machine Tool Transformers Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed

More information

Bulletin 1497A Machine Tool Transformers

Bulletin 1497A Machine Tool Transformers Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Bulletin 505 Full Voltage Reversing

Bulletin 505 Full Voltage Reversing Bulletin 505 Full Voltage Reversing Contactor Accessories Bulletin 500DC Electronic DC Coil Controller Compact size NEMA sizes 0 3 Versatility Fully assembled unit or as a retro fit kit Features LED status

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

CPT Series Control Transformers

CPT Series Control Transformers CPT Series Control s 50 VA to 500 VA 480 VAC Primary 120 VAC Secondary (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in: Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

PH250MQMJ CNTL 250VA 240X X240

PH250MQMJ CNTL 250VA 240X X240 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

Transformer Disconnects Specifying Product Catalog Numbers

Transformer Disconnects Specifying Product Catalog Numbers SPECIFYING PRODUCT CATALOG NUMBERS Transformer Disconnects Specifying Product Catalog Numbers When ordering, specify the following information: Class, Type, VA rating, Enclosure, Voltage code, and Form(s).

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FLQ4 4A 500V TD CT Midget Fuse Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Industrial Control Transformers

Industrial Control Transformers The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.

More information

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FLQ112 1-1/2A 500V TD CT Midget Fuse Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Application Information Need to know how? You ve turned to the right place...literally.

Application Information Need to know how? You ve turned to the right place...literally. Need to know how? You ve turned to the right place...literally. Your problem: Whether your objective is optimum protection of motor control equipment, power or control transformers, cable wiring, or lighting

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Low voltage, branch circuit fuses

Low voltage, branch circuit fuses Low voltage, branch circuit fuses Contents Description Page Fuse holder and block selection guide -2 Class fuse dimensions -5 Fuses by fuse class Class Fuses Volts CC....... LP-CC............... 600V.....

More information

Totally Enclosed Non-Ventilated

Totally Enclosed Non-Ventilated 5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units

More information

Equipment Protection. Transformers 600V or Less

Equipment Protection. Transformers 600V or Less Equipment s or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers,

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

50 Series. Features. Suffix Suffix Series Voltage Combinations

50 Series. Features. Suffix Suffix Series Voltage Combinations Features C 50 Combinations Suffix -052 x 24 ll Copper Windings Rugged coil mounted screw terminals UL Class 105 C insulation system, 55 C temperature rise through 750 UL Class 10 C insulation system, C

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Machine Tool Industrial Control Transformers

Machine Tool Industrial Control Transformers Hammond Power Solutions Inc. Page of Machine Tool Industrial Control Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

2 SLR Series Line Reactors... 50

2 SLR Series Line Reactors... 50 Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR225 225A 250V TD Class RK5 Dual Elem Fuse-Fusetron Number Manufacturer Description Weight per unit Product Category

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block Littelfuse Catalog Number LH600303C Manufacturer Littelfuse Description

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Harmonization of IEC and North American Safety Standards

Harmonization of IEC and North American Safety Standards Equipment SCCR made easy Harmonization of IEC and North American Safety Standards Dan Neeser Field Application Engineer Eaton s Bussmann Division DanRNeeser@Eaton.com Agenda UL 508C, UL 61800-5-1 and transition

More information

BH-1 modular fuse blocks, 700 V, 400 A

BH-1 modular fuse blocks, 700 V, 400 A Supersedes December 1998 Agency information UL Recognized, Guide IZLT2, File E14853 up to 700 V CSA Certified, Class 6225-01, File 47235 up to 700 V CE RoHS compliant Materials Base - light-weight, high

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Three-phase isolating transformers for photovoltaic and wind-power systems

Three-phase isolating transformers for photovoltaic and wind-power systems BTTTFV SERIES VERY LOW LOSSES THREE PHASE "GREEN ENERGY" TRANSFORMERS DRY TYPE THREE PHASES TRANSFORMERS Rated frequency: 50/60Hz Rated primary voltage: 400V Rated secondary voltage: 400V Group: YNyn0

More information

Bulletin 500FL Feed-Through Wiring Contactors For Non-Motor And Lighting Loads

Bulletin 500FL Feed-Through Wiring Contactors For Non-Motor And Lighting Loads Bulletin 500FL Feed-Through Wiring Contactors For Non-Motor nd Lighting Loads Bulletin 500FL Feed-through wiring electrically held For non-motor loads, lighting, and heating NEM sizes to 300 2- and 3-pole

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

Low Voltage, Branch Circuit Rated Fuses

Low Voltage, Branch Circuit Rated Fuses Low Voltage, Branch Circuit Rated Page Fuse Holder & Block Selection Guide 8-20 Class Fuse Dimensions 2-22 By Fuse Class Class Volts Low Voltage Branch Circuit CC...... LP-CC............... 600V..... 23

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.

More information

UL489 or UL1077? What are your Circuit Protection Requirements?

UL489 or UL1077? What are your Circuit Protection Requirements? UL489 or UL1077? What are your Requirements? An understanding of circuit types and circuit protection products is critical to ensure their proper application. See NEC Sections 100, 430 and 409 for definitions.

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Low Temperature Rise SolaHD low temperature rise transformers feature a 220 C insulation system and temperature rise of only 80 C or 115 C under full nameplate load. Reduction in temperature rise increases

More information

Ferrule fuses. High Speed Fuses

Ferrule fuses. High Speed Fuses Ferrule fuses Table of Contents Basic Catalog Amp Number Volts Range Page FWA 150 5-0 19-193 FWX 50 1-50 19-195 FWH 500 0.5-30 19-199 FWC 00-3 00-01 FWP 90V/700 1-100 0-05 FWK 750 5-0 0-07 FWJ 1000 0-30

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS.

TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS. TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS. NEM VCUUM CONTCTORS NEM VCUUM OPEN TYPE STRTERS NEM VCUUM COMBINTION STRTERS NEM VCUUM PUMP CONTROL PNELS INTRODUCING THE NEW LINE OF LLEN-BRDLEY NEM VCUUM CONTCTORS

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Drive Isolation & Protection

Drive Isolation & Protection Drive Isolation & Protection 2 Drive Isolation Transformers: 7.5 440, Three Phase Special s and Sizes for Drive Applications For SCR (Silicon Control Rectifier) variable speed motor drive applications,

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

Class H & K Fuse Holders - 250/600 Volt

Class H & K Fuse Holders - 250/600 Volt Class H & K - 250/0 Volt Specifications: Approved for 10,000 Amp Withstand Rating and Short Circuit Current Ratings (SCCR) UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant &

More information

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit

More information

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016 Supersedes April 2016 BUSSMANN SERIES CUBEFuse Compact Circuit Protector Base (CCPB) 2011/65/EU Features and benefits: Uses finger-safe, current-limiting Class CF CUBEFuse with Class J performance available,

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules. Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,

More information

CUBEFuse. CUBEFuse catalog numbers (amps)

CUBEFuse. CUBEFuse catalog numbers (amps) The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information