Molded Case Circuit Breakers
|
|
- Georgina Aubrey Wilkinson
- 5 years ago
- Views:
Transcription
1 Handle Ties Provide simultaneous switching of 2 adjacent handles. Do not provide common trip. For Use With Standard Wt Lb/ Breaker Frame(s) Package Std Pkg BQ, BQH, HBQ, B6, BLH, HBL (2 Pole) QTH3 0 1/4 Padlocking Devices For locking breaker in OFF position. BQXD, BQ, BQH, HBQ, BL, BLH, HBL ECQLD3 10 1/4 One pole BL, BLF, BE, BAF ECPLD1 3 1/4 Two-pole BL, BLF and BE ECPLD2 3 1/4 All QJ HL /4 All BQD, CQD BQDPLD 1 1/8 All ED ED2HPL 1 1/4 All FD FD6PL1 1 1/4 All JD, LD, LMD JD6HPL 1 1/4 All MD, ND, PD, RD MN6PLD 1 1/4 Filler Plates BQ, BQH, HBQ, BL, BLH, HBL QF3-UL 1 1/4 Handle Blocking Devices For holding breaker in ON or OFF position. Not a lockout/tagout device. BL, BLH, HBL, BQXD, BQ, BQH, HBQ ECQL1 2 1/4 QJ2, QJH2, QJ2H, HQJ2H QJHS1 2 1 All BQD, CQD, NGG BQDHBD 1 1/4 All ED E2HBL 1 1/4 All FD FD6HB1 1 1/2 All JD, LD, LMD JD6HBL 1 1/2 All MD, ND, PD, RD MN6BL 1 1/2 FD Padlocking Device FD6PLI ECQTH3 Filler Plate QF3-UL Padlocking Device ECQLD3 Handle Extensions For replacement. One extension shipped with breaker. All MD, ND, PD, RD EX Replacement Terminal Cover NGG RTCG3 10 1/4 FD Handle Blocking Device FD6HB1 Handle Blocking Device ECQL1 Handle Extension EX11 Sold only in standard package quantities. -69
2 Mounting Clips For Use With of Standard Wt Lb Breaker Frame(s) Poles Package Std Pkg BQ, BQH 1 MB0 20 1/4 Face Mounting Plates 1 FP /2 BQ, BQH, BQXD 2 FP FP /2 1 CQDFMB1 1 1/4 CQD, CQD6 2 CQDFMB2 1 1/4 3 CQDFMB3 1 1/4 BQ-GFCI 1 FP FMPG1 1 1/4 NGG 2 FMPG2 1 1/4 3 FMPG3 1 1/4 MB0 Face Mounting Plates FP98 FP908 FP9 FP96 Shallow Mounting Brackets BQ, BQH 1 6 SMB /4 Back Mounting Plates BQ, BQH, BQXD Mounting Screw Kits CQD, CQD6 CQDSMK 1 1 1/4 All ED (CED6 requires 2 kits) MSE6 1 1/4 MSE NNG MSKG2 1 1/4 All QJ MSQJ 1 1 All FD (CFD6 requires 2 kits) 2 BR2 10 1/4 3 BR3 10 1/4 4 BR4 10 1/4 ED2, ED4, ED6, HED4 1 E2BMB 1 1/4 MSF6 1 1/4 MSF All JD, LD MSJ6 1 1/4 All LMD MSLMD 1 1/4 All MD, ND, MSMN 1 1/4 All PD, RD MSPR6 1 2 MI Mechanical Interlocks For Use With Panel Plug-in Standard Wt Lb Breaker Type(s) Mounted Mounted Package Std Pkg BQ ECQML 10 1/4 All QJ CSO 1 1 All FD MI444 MI444 Complete with two breakers All JD, LD MI All LMD MI All MD MI All ND MI All PD, RD MI40 MI40 STD STDMIF32 SMB6 (6 shown) Back Mounting Plate BR2 Mounting Screw Kit MSE6 QML Mechanical Interlock MI444 Note: CSO = Consult Sales Office Kit consists of 4 screws and washers. Consists of 1 screw and washers (order 100). Consists of 1 screw and washers (order 0). With mechanical interlock in place, no accessory can be installed into circuit breaker right pole. Addition of the mechanical interlock will prevent accessory installation in the left pole. Sold only in standard package quantities. Multiply List Price Each times package quantity for full price. Each package contains strips of 6 each. Each strip can be broken at perforations for 1, 2 or 3-pole use. Mechanical interlock is not designed for use within Siemens panelboards. -70
3 Rotary Door Mounted Operating Handles Types 1, 3, 3R,, 4 4X For Use With Breaker Frames Complete Mechanism Standard Depth Variable Depth Handle Only Breaker Operator Shaft Only Length (inches) EG RHVE64X RHVE4X ED a CRHOESD CRHOEVD RHOEBO 2 RHOSSD FD CRHOFSD CRHOFVD RHOFBO RHOSVD CRHOH JD, LD CRHOJSD CRHOJVD c RHOJBO 16 RHOSXD LMD CRHOLMSD CRHOLMVD RHOLMBO 3 RHONSSD MD, ND RHONSD RHONVD RHOH RHONBO PD, RD RHONSVD 24 RHONSXD For 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. Rotary Door Mounted Operating Handles Types 1 & For Use With Breaker Frames Standard Depth Variable Depth Handle and Shaft Breaker Operator CQD, NGG RHOCQVD RHOH62 CQDOP ED D11CEU1 D11CEU2 FD D11CFU1 D11CFU2 JD, LD, LMD D11CJU2 RHOH D11CEU2 CRHOH Through Door Mounted Operating Handles Types 1 & Standard Depth Variable Depth For Use With Breaker Frames CQD, NGG FMHOS QJ OH9498 VH ED E2RH1 E2RHV FD F6RH1 F6RHV Door Latch Kits Type Right Hand Left Hand 2 point latch DKR2 DKL point latch DKR3 DKL Rotary Door Mounted Operating Handles Standard Depth F6RH1 Variable Depth F6RHV9 a For use on 3-pole ED frame only. b Meets the requirements of NFPA 79, section for locking external operator disconnecting devices. c For 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. d For extended shaft support order catalogue number RHONSB2. Consult Siemens Sales Office for NFPA-79 Compliance. -71
4 Max-Flex, Flange Mounted Variable Depth Operators c Frames NGG ED FD JD, LD, SJD, SLD LMD MD, ND, PD, RD, SMD, SND, SPD NEMA Type Complete Kit MFKG3R3 Handle Only MFHM3R 4 (x) MFKG4X3 MFHM4X FHOE036 a FHOH FHOF036 FHOH FHOJ036 FHOH FHOLM036 FHOH FHON048 FHOHN 4 (x) FHOHN4 Breaker Operator MFMG FHOEBO a FHOFBO FHOJBO FHOLMBO FHONBO 36" Cable MFCF036 FHOEC036 FHOFC036 FHOJC036 FHOJC036 FHONC048 b Max-Flex handles are available with solid black handles instead of the customary red for on flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter i to the catalogue number (e.g. FHOHI). Cable Max Flex Breaker Operator Handle Alternate Length Cable Only ED FD JD/LD/LMD MD/ND/PD/RD Inches 048 FHOEC048 FHOFC048 FHOJC048 FHONC FHOEC060 FHOFC060 FHOJC060 FHONC FHOEC072 FHOFC072 FHOJC072 FHONC FHOEC084 FHOFC084 FHOJC084 FHONC FHOEC096 FHOFC096 FHOJC096 FHONC096 0 FHOEC0 FHOFC0 FHOJC0 FHONC0 144 FHOEC144 FHOFC144 FHOJC144 FHONC144 Handle Auxiliary Switch For use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C). For Use With ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max Flex HAS1 Fixed Depth Flange Mounting Minimum Left Hand Mount Right Hand Mount Enclosure NEMA Frames Depth Type ED , 3R, FDFBEL FDFBER 4, 4X FDFBEL4 FDFBER4 FD , 3R, FDFBFL FDFBFR 4, 4X FDFBFL4 FDFBFR4 Max-Flex handles are available with solid black handles instead of the customary Red for On flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter i to the catalogue number (e.g. FHOHI). FDFBFR For 1- or 2-pole breaker order FHOED036 complete kit or FHOEDBO breaker operator only. b 48 inch cable is standard length for M through R frame Max-Flex operators. c Meets requirements of NFPA 79, section for locking external operator disconnecting devices -72
5 Telemand Motor Operator AC Hinged to List Breaker Frame Voltage Open Down Price $ EDexcept CED 0 MOE MOE6240 ED motor operator opens downward. Breaker DC Hinged to AC Hinged to Frame Voltage Open Right Voltage Open Right 24 MOF6024DC 0 MOF FD 48 MOF6048DC 240 MOF MOF6DC MOJ6024DC 0 MOJ JD, LD 48 MOJ6048DC 240 MOJ MOJ6DC 24 MOLMD6024DC 0 MOLMD LMD 48 MOLMD6048DC 240 MOLMD MOLMD6DC MD, ND, 0 MOMN PD, RD 240 MOMN To order FD through RD motor operators with Left side hinges, add L to catalogue number (e.g. MOF60L). Dimensions Frame A B C D E F ED FD JD, LD, LMD MD, ND, PD, RD Operating Currents On In-Rush Running Time In-Rush Running Time Reset (Amps) (Amps) (msec) (Amps) (Amps) (msec) (Amps) MOE MOE MOF60/L MOF6240/L MOLMD60/L MOJ60/L MOJ6240/L MOMN60/L MOMN6240/L Off FD, JD, LD, LMD, MD, ND, PD, RD Frames Front View Bottom View For inches / millimeters conversion, see Application Data section. -73
6 Plug-In Mounting Assemblies, Including Base and Tulip Assemblies Line Side Load Side Steel Switchboard For Use With Mounting Plate Breaker Frames Poles All ED 2 PC PC except CED 3 PC PC PL2616 CED 2 PC PC PC PC PL2617 All FD 2 PC PC except CFD 3 PC PC PL4762 CFD 2 PC PC PC PC PL4763 /Dimensions Base All JD 2 PC PC except CJD 3 PC PC PL796 Kit CJD, SCJD 3 PCCJD PCCJD PL797 All LD 2 PC PC except CLD 3 PC PC PL696 Kit CLD, SCLD 3 PCCLD PCCLD PL797 All MD 2 PC PC PC PC PL9698 All ND 2 PC PC664 c PC PC PL9699 Tulip Assemblies Separately 2 Pole 3 Pole For Frame ED TCE2 TCE FD TCF2 TCF JD TCJ2 TCJ LD TCL2 TCL MD TCM2 TCM ND TCN2 TCN Switchboard Mounting Plate RS476 Tulip Assemblies RS47 Rear-Connecting Studs For Use Extension With Behind Line Side Load Side Breaker Ampere Breaker Frames Rating Description (inches) 100 Line Side (Short) 2.38 RS All ED 100 Load Side (Short) 2.38 RS Line Side (Long) 4.88 RS Load Side (Long) 4.88 RS2642 All FD 20 Short 3. RS476 RS Long 7.06 RS47 RS All JD 400 Short.8 RS774 RS Long RS773 RS All LD CJD, SCJD CLD, SCLD 600 Short.8 RS784 RS Long RS783 RS Add required shield kit. CLRSJL3 4.0 LM(X)D6, 800 Short.8 RS788 RS HLM(X)D6 Long RS787 RS All MD, 00 Short.0 RS786 RS ND 00 Long 8.00 RS78 RS Circuit Breaker With Rear-Connecting Studs Built to order. Allow 7 9 weeks for delivery. Furnished at no extra charge when ordered with plugin mounting assembly. Each piece catalogue number consists of (1) mounting block assembly and required tulip assemblies (2) for 2-pole, (3) for 3-pole For vertical bus mounting for horizontal, substitute PC66 for PC664 and PC667 for PC666. Price includes one current stud, insulating tube, stud nuts and terminal shields, when required. For proper electrical clearance, studs must alternate between short and long stud lengths on circuit breaker poles (e.g. SLSLSL or LSLSLS). -74
Section 8. Switchboards. Contents. Sentron SMP, FCI, FCII Switchboards Type SMP. Selection Construction Details Specification Type FCI, FCII
Section Switchboards Contents Sentron SMP, FCI, FCII Switchboards Type SMP Features Selection Construction Details Specification Type FCI, FCII Features Selection Construction Details Specifications Protective
More informationMolded Case Circuit Breakers Reference Guide
Molded Case Circuit Breakers Plug-In Breakers Panelboard Breakers QT QP, QPP QPH, QPPH HQP, HQPP HQPPH QPJ BL BLH HBL BQD, BQD NGB NEB HEB Page 1-25 1-27, 1-29 1-27, 1-29 1-24, 1-29 1-24, 1-29 1-29 -18-18
More informationtype P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards
type P Lighting and Power Distribution Panelboards Specifications Main Breaker: 400A Maximum Main Lugs only: 400A Maximum Voltages: 480Y/277V AC Maximum 250V DC Maximum 3Ø3W, 3Ø4W, Ø3W, Ø2W General P panelboards
More informationEnclosed Circuit Breakers Enclosures Type 1
s Type Selection Figure Figure Figure Type K.O. Number Maximum Weight Fig. Breaker of Current Catalog List Lb./Ship. (inches) 6 Plcs. Plcs. No. Frame Poles Rating Number Price $ Package A B C D E F G H
More informationInstallation Instructions
Item: I-T-E Circuit Breaker Motor Operator For use with: See Table Below Page 1 of 6 Siemens Energy & Automation, Inc. Bellefontaine, Ohio 43311 U.S.A. DESCRIPTION severe injury. installing or servicing.
More informationEnclosed Circuit Breakers
Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,
More informationLighting Panelboards. P2 Panelboards
Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The
More informationAmpere Connectors Suitable for Copper or Aluminum 800 (3) - #3/0 AWG-500 Kcmil 1000 (4) - #3/0 AWG-500 Kcmil 1200 (4) - #3/0 AWB-500 Kcmil
Panelboards Type P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still a space saver
More informationSPEEDFAX TM 2011 Molded Case Circuit Breakers Contents
SPEEDFAX TM 2011 Molded Case Circuit Breakers Contents What s New in Circuit Breakers -3-4 Federal Specifications Classification -5 Catalog Numbering System -6-8 s -9-18 Load Center Breakers Arc Fault
More informationPanelboards. Type P3 Panelboards. General. Revised 04/15/14. Features
11 Panelboards Features Another innovation from Siemens is the P3 panel. It is a smaller, footprint distribution panel to fit a large number of applications that require more (or larger) branch devices
More informationEnclosed Circuit Breakers
s Type Selection Figure Figure Figure Type K.O. Fig. Breaker of Current Catalog Lb./Sip. Plcs. Plcs. No. Frame Poles Rating Number Package A B C D E F G H QP, QPH, HQP EMLS acg 8 5 8 8 5 QP, QPH, EMLS
More informationMolded Case Circuit Breakers
mmmmmmmm Q5A Frame SLCTION Ordering Instructions All BQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix 'L' to catalog number. Lugs will be supplied at no
More informationPanelboards Circuit Breaker / Lighting and Distribution
Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating
More informationBoxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.
Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationEnclosed Circuit Breakers
Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,
More informationPANELBOARDS SECTION 1
SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector
More informationSection 6. Molded Case Circuit Breakers. Contents. VLThermal Mag and Electronic Circut Breakers What s New in Circuit Breakers
Section m Molded Case Circuit Breakers /3 Applicable Standards /3 Reference Guides /5 Panelboard Mtg Circuit Breakers BL, GFCI, AFCI /13 BQ 125A Frame, Switching Neutral, DIN Rail /17 QJ 225A Frame /19
More informationPOWER PRODUCT Molded Case Circuit Breakers Contents
POWER PRODUCT Molded Case Circuit Breakers Contents Introduction -2 Catalogue ing System -3 Reference Guides - Panelboard Mounting Circuit Breakers BL -13 GFCI, AFCI -1 BQ 12A Frame, Switching Neutral,
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationa Alternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens.
11 PANELBOARDS Panelboards P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still
More informationSentron SMP Switchboards
8 SWTBOARDS Sentron SMP Switchboards onstruction Details Simplified system design. A typical SMP switchboard consist of a floor mounted, wall supported service section, and a distribution section. The
More informationMolded Case Circuit Breakers
Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A
More informationPOWER PRODUCT Molded Case Circuit Breakers Contents
POWER PRODUCT Contents Introduction -2 Catalogue ing System -3 Reference Guides - Panelboard Mounting BL -13 GFCI, AFCI -1 BQ 12A Frame, Switching Neutral, DIN Rail -16 BQD, BQD6-18 QJ 22A Frame -19 CQD
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron ED Breakers 240V 480V 600V ED2 0KAIC ED4 65KAIC 8KAIC ED6 65KAIC 25KAIC 8KAIC -, 2- & 3-pole up to 25A for circuit protection up to 600 volt circuits (UL/CSA/IEC) General
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationSiemens SPD TOTAL HOME SURGE PROTECTION
TOTAL HOME SURGE PROTECTION All Appliances Coax Phone Purge damaging surges at the source and protect home electronics with Siemens SPD - Home Entertainment - Kitchen & Laundry Appliances - Home Security
More informationPOWER PRODUCT Panelboards Contents
POWER PRODUCT Panelboards Contents Features, Reference Guide & General Specifications -2-7 Factory Assembled Panelboard Coding System -8 Type P1 Specifications -9 - Unassembled panelboard -11-12 Main Lug
More informationIntroduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3
Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change
More informationDisconnect Enclosures
Wall-Mount Enclosures Type 12 Flange-Mount....................................................................... 296-298 Wall-Mount Enclosures Type 4 & 4X Premier Series 2-Point or 3-Point Locking..........................
More informationMolded Case Circuit Breakers
SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A
More informationRXT. Model: Model RXT Automatic Transfer Switch
Model: RXT Automatic Transfer Switch -- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers 600V Circuit Breakers Sentron ED Breakers 240V 480V 600V ED2 10KAIC ED4 65KAIC 18KAIC ED6 65KAIC 25KAIC 18KAIC 1-, 2- & 3-pole up to 125A for circuit protection up to 600 volt
More informationRXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Available Models. Automatic Transfer Switch Amps
Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationRXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Automatic Transfer Switch Amps
Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationaalternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens.
Panelboards P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still a space saver with
More information22.000A IR. Catalog Number. Price $
Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List
More informationRetail Reference Guide
www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology
More informationDisconnect Enclosures
llen-radley * Do not install s in this depth enclosure. 1494V Disconnect Mechanism llen-radley Fuse lip Rating Fuse Mechanism mp lass (when enclosure depth is:) installed. Fit and function of all equipment
More informationSelection and application guide. Panelboards P1 thru P5.
Selection and application guide Panelboards P1 thru P5 www.usa.siemens.com/panelboards 1 SECTION Contents PAGE Introduction 2 General Specifications 3-5 Catalog Numbering System 6 A detailed Table of
More informationDisconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle
Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies
More informationTYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS
TYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: 14 gauge steel. Seams are continuously welded and ground smooth. External mounting feet. Door and body stiffeners in larger enclosures
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More informationRevised P1 Panelboards
Panelboards (Introduced January 2015) Data Sheet The Panelboards are now available in both Feed-thru (FT) and Non-Feed-thru (NFT) variations. There is a savings of 6 of box height when a NFT version is
More informationModifications. Marine 50 C Ambient Calibration
1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH
More informationAE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets
FMD ENCLOSURES AE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets Superior in design, Rittal's AE flange mounted disconnect enclosures have fewer moving parts, which reduces assembly and installation
More informationUHD Heavy Duty Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D
UHD Heavy Duty Enclosures - NEMA 12 3UHD Shown Application Designed to accept the following dis connect switches and circuit breakers: ABB Controls fl ange mounted variable depth operating mechanisms for
More informationMolded Case Circuit Breakers
Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B210 15 B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235
More informationType MP-T Type MP-HT Type MP-MT
CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List
More informationCircuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13
Circuit Breakers Lug-In/Lug-Out with INSTA-WIRE 03/06/3 All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix L to catalog number. Consult Siemens
More informationModifications. Marine 50 C Ambient Calibration
1-Pole Bolt-On (1V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 B1 B1H B1HH B1 B1H B1HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH 40 B140 B140H B140HH
More informationDisconnect Enclosures
llen-radley 1494V or 1494U Disconnect Mechanism llen-radley Fuse lip Rating Fuse Mechanism mp lass (when enclosure depth is:) for Switches mp Volt 8 10 12 16 DS30 30 (non) (non) -- 5.75 146 6.37 162 73
More informationDisconnect Enclosures
Disconnect Ordering Information ABB Controls Disconnect switch: flange operated switch (fusible or nonfusible) shaft: DSFHS-2 handle: DSFHN-HS4 Circuit breaker: circuit breaker: ABB operating mechanism
More informationTYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS
TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: Finish: Type 4 enclosures are painted ANSI 61 gray polyester powder outside and inside. Type 4X enclosures are unpainted.
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationHammond Series 1447SN4 & 1447SN4SS EN4DCS all versions ABB Disconnect Switch. Quality Enclosures. Service Excellence.
Single Door Enclosures - NEMA 4, 4X Selection Guide Hammond Series 447SN4 & 447SN4SS EN4DCS all versions ABB Switch Flange operated switch (fusible or non-fusible) Shaft: 8-2 dp enclosures, use DSFHS-2;
More informationMolded Case Circuit Breakers
SPEEDFAX TM 20 Section Dual Function Circuit Breaker Scan to connect online to the most up-todate version of this Section of SPEEDFAX. NGB Circuit Breakers QR Circuit Breakers c o n t e n t s What s New
More informationDisconnect Enclosures
447A Single Door - NEMA, 3 Allen Bradley Inner Panel Included Application Designed to house Allen Bradley 494F flange mounted disconnect switches and 494D flange mounted circuit breaker operators (will
More informationIntroduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection
Table of Contents Introduction... 2 Need for Circuit Protection... 4 Types of Overcurrent Protection Devices... 6 Circuit Breaker Design... 9 Types of Circuit Breakers... 20 Circuit Breaker Ratings...
More informationPOWER PRODUCT Disconnect Switches Contents
4 POWER PRODUCT Disconnect es Contents Compact Non-Fusible es 4-2 Rotary and Toggle Selection 4-4 Dimensions and Wire Ranges 4-5 Type VBII (0-A) Features and Ordering Information 4-6 and Handle Selection
More informationPanelboards 11 PANELBOARDS. Unassembled. Reference. Catalog Numbering System. Branch Breakers
Panelboards Unassembled ing System Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally feed-thru lugs, or a subfeed circuit breaker up
More informationand legacy Motor Control Center Aftermarket Renewal Parts Catalog
tiastar TM and legacy Motor Control Center Aftermarket Renewal Parts Catalog Game Changing Innovation www.usa.siemens.com/mcc Answers for industry. Table of Contents Ordering Processes 1-2 Section Parts
More informationModel: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models
Model: RXT Automatic Transfer Switch 100 - Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationDisconnect Enclosures
40 447A Single Door - NEMA 2, 3... 42-45 UHD Heavy Duty - NEMA 2... 92 447S Single Door - NEMA 2, 3... 47-59 447SN4 Single Door - NEMA 4, 4X... 60 UHD One Door Heavy Duty Disconnect Enclosures - NEMA 2...
More informationModel: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models
Model: RXT Automatic Transfer Switch 100 - Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service
More informationRevised P1 Panelboards
Data Sheet Panelboards (Introduced January 2015) The Panelboards are now available in both Feed-thru (FT) and Non-Feed-thru (NFT) variations. There is a savings of 6 of box height when a NFT version is
More informationIntroduction. Upon completion of Molded Case Circuit Breakers you will be able to: Explain the need for circuit protection
Table of Contents Introduction...2 Need for Circuit Protection...4 Types of Overcurrent Protective Devices...8 Circuit Breaker Design...11 Types of Circuit Breakers...24 Circuit Breaker Ratings...29 Time-Current
More informationPOWER PRODUCT Molded Case Circuit Breakers Contents
POWER PRODUCT Molded Case Circuit Breakers Contents Dual Function Circuit Breaker NGB Circuit Breakers What s New in Circuit Breakers -3-4 Catalogue Numbering System - -7 Reference Guides -8-17 Panelboard
More informationSelection and application guide
Selection and application guide Integrated Power Systems Switchboards www.usa.siemens.com/switchboards Integrated Power Systems Switchboards Contents General Product Information 2-3 General Layout Information
More informationEnclosed Circuit Breakers
Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationSIEMENS. Information and Instruction Guide E Frame TypeCLE A. Molded Case Circuit Breakers. www. ElectricalPartManuals. com. Bulletin IB-2.2.
/ SEMENS nformation and nstruction Guide E Frame TypeCLE A Bulletin B-2.2.8-1 A Molded Case Circuit Breakers Page 2 nformation and nstruction Guide T E E Frame Type CLE A Model ETCL 2 and 3 Poles 15 125
More informationRevised P1 Panelboards. Quick reference guide for selection and application. usa.siemens.com/panelboards
Revised P1 Panelboards Quick reference guide for selection and application usa.siemens.com/panelboards Introducing the Siemens Revised P1 Panelboard Siemens is proud to introduce new, innovative additions
More informationType VBII Visible Blade Disconnect Switches
Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin CWY (painted steel) Or Hoffman Bulletin CWSD (stainless steel) CONCEPT Wall Mounted Disconnect Enclosures
More informationOPERATOR ADAPTER A21ITE
OPERATOR ADAPTER A21ITE Installation Instructions for I T E MAX FLEX (For parts list, see page 2) For floor mounted enclosures with disconnect on the right flange, see pages 3 6 Master Door For one through
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin A19 (painted steel) Or Hoffman Bulletin A19S (stainless steel) Wall Mounted Disconnect Enclosures Rev.
More informationF LANGE MOUNT DISCONNECT
F LNGE MOUNT DISCONNECT E Wallmount FMD s... FMD 1-2 NEM 4 Wallmount Boxes... FMD 3-4 NEM 12 Wallmount Boxes... FMD 5-6 TS8 Freestanding FMD s... FMD 7-8 PS Freestanding FMD s... FMD 9-10 Freestanding
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationDisconnect Enclosures
Type 12 Heavy-Duty Single & Multi-Door Data Sheet pplication Houses electrical controls and equipment Protects against circulating dust, falling dirt and dripping non-corrosive liquids Standards UL 508
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationTYPE 12 FREESTANDING DOUBLE DOOR ENCLOSURE FOR FLANGE-
TYPE 12 FREESTANDING DOUBLE DOOR ENCLOSURE FOR FLANGE- MOUNTED DISCONNECT Construction: 10 gauge steel. Seams continuously welded and ground smooth. Body stiffeners in larger enclosures for extra rigidity.
More informationUL Enclosed Disconnect Switches (Fused and Non-Fused)
Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66
More informationContents. 4 Loadcentres
POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationSN4 SERIES ENCLOSURES NEMA 4 FLANGED SINGLE DOOR DISCONNECT
R 6 SN4 SERIES ENCLOSURES NEMA 4 LANGED SINGLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 3, 4, 12, & 13 JIC EL-1-71 UL ile E64791 SN4242108
More informationF20 SSN4X SERIES ENCLOSURES NEMA 4X FLANGED SINGLE DOOR DISCONNECT
R 20 SSN4X SERIES ENCLOSURES NEMA 4X LANED SINLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 4X, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 4, 4X, 12, & 13 JIC EL-1-71 UL ile E64791
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More informationCATALOG: Distributions & Controls
CATALOG: Distributions & Controls **Wolff Bros. Supply, Inc. reserves the right to substitute like products. Product information is subject to Manufacturer rolling changes and/or typographical errors.
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationUL 1008 Withstand and Close On Ratings
Power topic #5410785 Technical information from Cummins UL 1008 Withstand and Close On Ratings White Paper By Rich Scroggins, Technical Advisor Electrical distribution system design requires sizing equipment
More informationFREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures
118 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST 11 ENCLOSURE Panels (Full & Half Length) For Single-Door Enclosures Panels for single-door enclosures can
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More information