SPEEDFAX TM 2011 Molded Case Circuit Breakers Contents

Size: px
Start display at page:

Download "SPEEDFAX TM 2011 Molded Case Circuit Breakers Contents"

Transcription

1 SPEEDFAX TM 2011 Molded Case Circuit Breakers Contents What s New in Circuit Breakers -3-4 Federal Specifications Classification -5 Catalog Numbering System -6-8 s Load Center Breakers Arc Fault and Ground Fault Breakers -19 QP, 1 Inch Breakers -20 QT, ½ Inch Breakers -21 Special Application Breakers -22 QD ¾ Inch Breakers -23 Main and Branch Breakers Circuit Breaker Dimension Drawings -26 Circuit Breaker Lug Data -2 Surge Protection -28 Panelboard Mounted Circuit Breakers BL 240V Breakers -29 BL 240V Arc Fault and Ground Fault Breakers -30 Special Application 240V Panelboard Mounted Breakers -31 BQD 100A Frame 480/2V Breakers -32 NGB 125A Frame 600/34V Breakers -33 Internal Accessories for BQD and NGB Breakers -34 EB 125A Frame 600/34V Breakers and Internal Accessories General Application Circuit Breakers BQ 240V Breakers -3 BQXD 240V DIN Rail Mounting Breakers -38 QJ 225A Frame 240V Breakers -39 CQD 100A Frame 480/2V Breakers -40 NGG 125A Frame 600/34V Breakers -41 Internal Accessories for CQD and NGG Breakers -42 EG 125A Frame 600/34V Breakers and Internal Accessories Sentron Thermal Magnetic and Electronic Circuit Breakers ED 125A Frame 600V Breakers and Internal Accessories FD 250A Frame 600V Breakers and Internal Accessories JD/SJD 400A Frame Breakers and Internal Accessories LD/SLD 600A Frame Breakers and Internal Accessories LMD 800A Frame Breakers and Internal Accessories MD/SMD 800A Frame Breakers and Internal Accessories ND/SND 1200A Frame Breakers and Internal Accessories PD/SPD 1600A Frame Breakers and Internal Accessories -0-2 RD 2000A Frame Breakers and Internal Accessories -3 Magnetic Trip Only ETI Motor Circuit Protectors -4-6 Adjustable Instantaneous Magnetic Trip Settings - -9 Molded Case Switch Circuit Disconnect -80 Digital Solid State Sentron Sensitrip III Series Trip Units WL Power Circuit Breakers Electronic and Communications Accessories -8 Lug Information Breaker Modifications -91 Internal Accessories Feature Combinations -92 External Accessories Unusual Operating Conditions (continued on next page) Residential L Commercial L Industrial

2 SPEEDFAX TM 2011 Molded Case Circuit Breakers Contents VL Thermal Magnetic and Electronic Circuit Breakers Technical Overview Trip Unit Overview DG 150A Frame and Internal Accessories FG 250A Frame and Internal Accessories JG 400A Frame and Internal Accessories LG 600A Frame and Internal Accessories MG 800A Frame and Internal Accessories NG 1200A Frame and Internal Accessories PG 1600A Frame and Internal Accessories Molded Case Switch -134 Motor Circuit Protector -135 VL 600 Volt DC Circuit Breakers -136 External Accessories Accessory Locations -152 Suffix for Factory Mounted Internal Accessories -153 Technical Data Unusual Operating Conditions General Technical Series Short Circuit Ratings Sentron IEC 9402 AC Interrupting Ratings -16 Typical Specifications -168 Superseded Circuit Breakers Residential L Commercial L Industrial

3 Molded Case Circuit Breakers Introduction What s new in molded case circuit breakers: Siemens BL and NGB circuit breaker families are now eligible to be marked NAVAL for use on non-combat vessels. These breakers meet the requirements of UL 489 Supplement SB. Consult your local sales office for availability. BL NGB Now available from stock Siemens offers distribution lugs for the NGG circuit breaker family for use in UL 508A control panels. These lugs will accept up to (6) copper wires from #14 to #4 gauge or aluminum wires from #6 to #4 gauge. Siemens now offers a line of VL circuit breakers which are rated for use at 600VDC with interrupting ratings between 42KAIC and 65KAIC. BQD and NGB handle ties are now released for use where single pole breakers are using shared neutrals and must be locked out simultaneously. + LOAD Circuit Breaker and Surge Protective Device (SPD) By installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuits (1). - UL and CSA, Meets UL rd Edition - Easy to install and perfect for retrofit - Offer in 15 or 20 amps - LEDs provide protection status (1) See warranty for detailed coverage information. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -3

4 Molded Case Circuit Breakers Revised 02/25/16 Introduction Ordering In the FD through RD frames, you may order molded case circuit breakers three basic ways: b As separately ordered frames, trip units and lugs b As frame, trip unit and lugs ordered as one catalog number and shipped unassembled or assembled b As Frame and Trip Unit shipped assembled and with the trip unit made non-removable, in compliance with UL 489 requirements that to be reverse fed the circuit breaker must not have an interchangeable trip unit. These two options are described in the following: Components Ordered Separately To get the components for a 3-pole, 400 Amp standard interrupting circuit breaker, you would order the frame (JD63F400), the trip unit (JD63T400) and six lugs (TA2J6500). This option is normally useful only if you stock and use large volumes of product and wish to reduce your inventory cost. You may stock, for example, a smaller number of frames (JD63F400) and a variety of trip units (JD63T300, JD63T350, etc.) and assemble breakers as you need them. Frame, Trip Unit and Lugs Ordered Together If you order the catalog number JD63B400, you will receive a frame, a trip unit and 6 lugs in separate packages. By suffixing this number with L (e.g. JD63B400L), you will receive frame, trip unit and lugs assembled in one container. Pursuant to UL 489, a product ordered thus will have the markings LINE and LOAD, and may not be reverse fed (with power flowing from the OFF end of the breaker toward the ON end). Non-Interchangeable Trip Breakers If you place an X after the frame size designator (e.g. JXD63B400), you will receive a frame and trip unit assembled, with the trip unit made non-removable. If you suffix an L to this catalog number (e.g. JXD63B400L), you will receive the breaker, non-removable trip unit and lugs assembled. Unless you anticipate a specific need to change the breaker s ampere rating in the future, this is the preferred ordering method, as the products are assembled to Siemens specifications in our factories. These breakers are suitable for use reverse fed according to UL 489, since the trip unit is not removable. The smaller frames (QJ, ED and below) do not have removable trip units, and consequently are shipped only as assembled products. To add lugs, see the ordering instructions on each product s catalog page. 500V DC Wiring Configuration Connecting Breakers for DC Application Most Siemens thermal magnetic trip MCCBs are applicable on direct current (dc) systems. Generally, for 250 V dc systems a two pole breaker is used, with one pole on each leg of the supply circuit. For three pole breakers applied on 500 V undergrounded DC systems, it is important to connect the power supply zig-zag through the breaker as shown in the figure below. This assures that the Voltage between phases on the breaker terminals is uniformly distributed. See below for an alternative connection diagram. For a list of Sentron breakers with the DC ratings, please refer to pages -11 to V MAX. 300 V MAX. Load/Carga/ Charge -4 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

5 Molded Case Circuit Breakers Federal Specification Classification W-C-35C/GEN Interrupting Rating Breaker Type (All Circuit Breakers Meet or Exceed Class Symmetrical Amperes a Volts AC 60HZ Poles Range of Current Trip c the Indicated Class Level) 10a b 5, /240 1 or QP, BQ, QT, BL 10b 5, or QP, BQ, BQD, CQD, BL 11a, QP, BQ, BQD, CQD, BL 11b, or QP, BQ, BQD, CQD, BL 12a b 10, /240 1 or QP, BQ, QT, ED2, BL 12b 10, or QP, BQ, QJ2, ED2, BQD, CQD, BL 12c 10, bqd, cqd, NGG, NGB, NEG, NEB 13a 14, ed4, bqd, cqd, NGG, NGB, NEG, NEB 13b 14,000 2/480 1, 2, or ed4, bqd, cqd 14a 22, /240 1 or qph, bqh, blh 14b 22, or qjh2, qj2-h, bqh, bqd, cqd, blh Reference 15a 65, /240 1 or hqp, hbq, ed4, hed4, NGG, NGB, NEG, NEB 15b 65, or ed6, ed4, fxd6, fd6, hed4, bqd, cqd, hqj2h, NGG, NGB, NEG, NEB 16a 100, or cfd6, ced6 16b 100, or ced6, cfd6, cjd6, scjd6, cld6, scld6 1a 200, or , a 14, or ed6, hed6, hhed6 14, , a 18, or fxd6, fd6, cfd6, hfd6 14, , a 22, or fxd6-a, fd6-a, cfd6, hfd6 22, , a 30, or , hfd6, cfd6, jxd6(a), JD6(A), sjd6(a), hjd(a), hjxd6(a), hhjd6, shjd6(a), cjd6, Scjd6, lxd6(a), ld6(a), sld6(a), hld6(a), hlxd6(a), hhld6, sld6(a), shld6(a), cld6, scld6, lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6, smd6, hmd6, hmxd6, shmd6, cmd6, scmd6 65, a 25, or ced6, ed6, hed6, hhed6, fxd6-a, fd6-a 18, HHED6, FXD6-A, FD6-A, hfd6, hhfd6, cfd6, Jd6(a), jxd6(a), sjd6(a), hjd6(a), hjxd6(a), shjd6(a), hhjd6, hhjxd6, cjd6, scjd6, 65, lxd6(a), ld6(a), sld6(a), hld6(a), hlxd6(a), 23a 35, or shld6(a), hhld6, hhlxd6, cld6, scld6, 25, lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6, smd6, hmd6, hmxd6, shmd6, cmd6, scmd6, nd6, nxd6, snd6, hnd6, hnxd6, shnd6, cnd6, scnd6 65, a 50, or , , a 80, or , Applicable Standards UL489 Molded Case Circuit Breakers and Circuit Breaker Enclosures. UL486A Wire Connectors and Solderless Lugs for use with copper wire UL486B Wire Connectors and Solderless Lugs for use with aluminum wire UL943 Ground Fault Interrupters (for personnel protectors) UL108 Molded Case Switches PD6, PXD6, HPD6, HPXD6, CPD6 RD6, RXD6, HRD6, HRXD6, SPD6, SHPD6 HHLD6, CLD6, CMD6, CND6 SCLD6, SCMD6, SCND6, CPD6 UL50 Cabinets and Boxes UL869 Service Equipment NEMA AB-1 Molded Case Circuit Breakers and Molded Case Switches CSA C22.2 No. 5, C22.2 No. 14 Note: (A) Molded case circuit breakers are designed and tested in accordance to applicable portions of UL489 and meet application requirements of the National Electric Code. Unless marked otherwise, circuit breakers are 80% duty rated. (B) Molded case circuit breakers are to be connected with 60 or 5 C wire for circuit breakers having a rated ampacity of 100 amperes or less. Circuit breakers having a rated ampacity greater than 100 amperes shall only be cabled with 5 C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in the article C(1)(2) of the 2005 National Electric Code. a Interrupting ratings are not limited to the values or groups of values listed. However, the values listed are minimum values for the class specified. b Single-unit or duplex construction must be specified. c Use minimum frame size for ampere rating. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -5

6 Sentron Molded Case Circuit Breakers Catalog Numbering System If used on 250A frame and above means non-interchangeable trip breaker with factory assembled frame and trip. Solid state trip and current limiting (S or C in first character) are non-interchangeable only, and the X is omitted. X D Trip Unit Type Omitted Thermal-Magnetic S Sensitrip Electronic Trip Sentron Series Type/Interrupting Range Omitted Standard Rating H High IC Rating HH Extra High IC Rating C Highest IC Rating and Current Limiting Frame Identifier E Type ED M Type MD F Type FD N Type ND J Type JD P Type PD L Type LD R Type RD LM Type LMD Maximum Voltage Vac Vac Vac Number of Poles used to indicate the max. functions for an electronic trip circuit breaker (always 3 poles) (Specific Application Type) B Standard 40 C Breaker M Calibrated for 50 C Application F Frame Only T 40 C Trip Unit Only W 50 C Trip Unit Only S Molded Case Switch L Low Instantaneous Range ETI Breaker A Standard Range ETI Breaker H High Instantaneous Range ETI Breaker Maximum Continuous Current Rating ED Frame 015, 020, 025, 030, 035, 040, 045, 050, 060, 00, 080, 090, 100, 110, 125 FD Frame 00, 080, 090, 100, 110, 125, 150, 15, 200, 225, 250 JD Frame 200, 225, 250, 300, 350, 400 LD Frame 250, 300, 350, 400, 450, 500, 600 LMD Frame 500, 600, 00, 800 MD Frame 500, 600, 00, 800 ND Frame 900, 100 (1000A), 120 (1200A) PD Frame 120 (1200A), 140 (1400A), 160 (1600A) RD Frame 160 (1600A), 180 (1800A), 200 (2000A) Suffix L where applicable indicates a breaker shipped with line/loads lugs installed A used with a switch to show automatic self protection Y 400 Hertz H 100% rated P Load side lugs only NOTE: Position omitted if not used. -6 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

7 VL Molded Case Circuit Breakers Catalog Numbering System Revised 11/15/13 Interrupting Class N Normal H High L Very High C Trip Unit Only Frame Family D Type DG F Type FG J Type JG Breaker Type L Type LG M Type MG N Type NG E Global DG Frame Only 600 Y/34 V G Global interchangeable (UL, IEC, CE, CSA, NOM, CCC ) J 240V rated JG frame, Non-interchangeable only K Global, Non-interchangeable (DG, LG-frame) M Motor Circuit Protector P Motor Circuit Protector (DG Only) P Type PG R Molded Case Switch (DG, LG-frame) S Molded Case Switch T Trip Unit Only V Thermal Magnetic, standard 40 C ambient, 600VAC 25kA, UL/CSA (LG frame) W 100% rated, Non-interchangeable (DG, LG-frame) X Global Non-interchangeable Y 100% rated, Non-interchangeable Number of Poles 2, 3 Trip Unit F Frame only, without trip unit S Molded Case Switch B Thermal Magnetic, standard 40 C ambient A Electronic w/ LCD, LSI or 3P (neutral protected) L Magnetic Only, Motor Circuit Protector - Low G Electronic w/ LCD, LSIG, 3P/4W (selectable residual or instantaneous range return type ground fault protection) J Magnetic Only, Motor Circuit Protector - Low K Electronic with LCD, LSI and GF alarm only, 3P/4W instantaneous range (LG-frame) (selectable residual or return type ground fault alarm) M Magnetic Only, Motor Circuit Protector - Standard R Electronic LI or 3P (neutral protected) instantaneous range T Electronic LSI or 3P (neutral protected) Y Magnetic Only, Motor Circuit Protector - Standard V Electronic, LSIG or 3P/4W, residual ground fault protection instantaneous range (LG-frame) W Electronic, LIG or 3P/4W, residual ground fault protection H Magnetic Only, Motor Circuit Protector - High instantaneous range Continuous Current Rating For DG use 050, 060, 00, 080, 090, 100, 110, 125, 150 For FG use 100, 110, 125, 150, 15, 200, 225, 250 For JG use 250, 300, 350, 400 For LG use 400, 500, 600 For MG use 600, 00, 800 For NG use 800, 900, 100 (1000A), 120 (1200A) For PG use 120 (1200A), 140 (1400A), 160 (1600A) Terminations B Load End Standard (cu/al) Lugs L Line & Load Standard (cu/al) Lugs X No Lugs (use only if accessory suffixes are to follow) Accessories Auxiliary and Alarm Switch Combinations Suffix Description A1 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames DG to LG) Note: A1 and A3 include 1NO and 1NC switch for A2 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames DG to LG) alarm purposes, only one of these switches may A3 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames DG to LG) be used as there is only one space for an alarm. A3 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames MG to PG) A4 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames MG to PG) Shunt Trips RB 24 VDC RM VAC RC VDC RN VAC RD VDC RS VAC LCD = Liquid Crystal Display RE 250 VDC RV VAC LI = Long Delay & Instantaneous trip functions LSI = Long Delay, Short Delay, & Instantaneous trip functions Under Voltage Releases UA 12 VDC UN VAC LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions GF = Ground Fault UB 24 VDC UP 208 VAC 3P = 3-pole UC 48 VDC UR VAC 4W = 4-wire UD VDC US 2 VAC UE VDC UT VAC UG 60 VDC UU VAC UK 24 VAC Select Frames Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -

8 VL Circuit Breakers Catalog Numbering System If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples below for a detailed explanation. The 15 digit number is achieved by placing X s in positions not being occupied by an accessory/modification. Contact Siemens for circuit breakers configured with accessories. Auxiliary Switch Example: H F G 3 B L A 2 X X X X Standard 9-digit Aux. Switch Completes Cat # Revised 02/26/12 Selection Shunt Trip / UVR Example: H F G 3 B L X X U N X X Standard 9-digit UVR Completes Cat # Shunt Trip / Auxiliary Switch Example: H F G 3 B L A 2 R N X X Standard 9-digit Aux. Shunt Completes Switch Trip Cat # Non-Interchangeable Trip Breakers Example: H F X 3 B L Standard 9-digit -8 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

9 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers Plug-In Breakers Panelboard Breakers Revised 0/20/14 QT QP, QPP b QPH, QPPH b HQP, HQPP b HQPPH b QPJ i BL BLH HBL BQD, BQD6 NGB NEB HEB Page , , , , Poles 1, 2 1, 2, 3 1, 2, 3 1, 2, 3 g 2 2, 3 1,2,3 1,2,3 1,2,3 1,2,3 1,2,3 1,2,3 1,2,3 Amperes cd cd cg Pole 120/ / / / / / / / /240 Volts (50/60 Hz) 2 Pole 120/ / / /2 600/34 600/34 600/34 3 Pole /2 600/34 600/34 600/34 120V 10,000 10,000 22,000 65, V 10,000 10,000 22,000 65, ,000 10, V V UL AC 480/2V Ratings 480V Interrupt 600/34V Ratings 600V /240V l CU l CS IEC /415V l CU /60 Hz l CS V l CU l CS 125/250 V DC Interrupting 2-Pole DC Rating 3-Pole A Height 10-60A 3.12 Dimensions in Inches Overcurrent Devices Accessories & Modifications Individual Enclosures A i Pole Width 2-Pole 2.00 a 2.00 b 2.00 b b i Pole 2.00 a i Depth Thermal and Fixed magnetic Trip u u u u u u u u u u u u u Thermal and Adjustable Magnetic trip Adjustable Magnetic trip only Motor Circuit Protector Molded Case Switch uf u u Undervoltage Trip u u u Shunt Trip uf uf uh uh u u u u u u u Auxilary Switch uh u u u u u u u Alarm Switch u u u u Mechanical Interlock u u Fungus Proofing (ref. page -91) u u u u u u u Type 1 - Indoor Surface u u u u u Type 1 - Indoor, Flush u u u u Type 3R - Outdoor-Rainproof u u u u QP BL, BLH, HBL BQD, BQD6 NGB NEB/HEB For inches / millimeters conversion, see Application Data section. For Plug-in Breakers, see Load Centers & Circuit Breakers section. a BQD6 CSA certified 600Y/34V 15 0A only. b Types QPP, QPPH, HQPP and HQPPH are special 2-pole configurations for metering equipment. Amperage range = A, width = 4 in. c Single pole breakers available in ratings 10 0A only. d 125A, 2-pole 120/240V AC only. f Not applicable to types QPP and QPPH. g Single pole circuit breakers available in ratings 15-0A only, 125A available as a 2-pole only. h Not applicable to type HQPP and HQPPH. i Fits only Siemens EQIII load centers. Breaker is 2 or 3 poles wide. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -9

10 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers General Purpose Breakers BQ BQH HBQ QJ2 QJH2 QJ2-H HQJ2 CQD NGG Page Ratings AC DC Poles 1, 2, 3 1, 2, 3 1, 2, 3 2, 3 2, 3 2, 3 3 1, 2, 3 1, 2, 3 1-Pole Amperes, Continuous 2-Pole Pole Pole / / /240 Volts (50/60 Hertz) 2-Pole /2 600/34 3-Pole V 10,000 22,000 65,000 65,000 65,000 UL Interrupting Rating 240V 10,000 22,000 65,000 10,000 22,000 42,000 65,000 65,000 65,000 Symmetrical RMS Amperes 480V 14,000 c 25, /34V 10,000 b 14,000 Volts 2-Pole 125/ /250 Interrupting Rating DC Amperes 14,000 14, A H height A Dimensions in A inches 1-Pole Width 2-Pole Pole Depth Overcurrent Thermal and Fixed Magnetic Trip u u u u u u u u u Devices Molded Case Switch u u Undervoltage Trip u Shunt Trip u u u u a u a u a u a u u Accessories & Auxiliary Switch u u u u a u a u a u a u u Modifications Alarm Switch u u u u Individual Enclosures Revised 01/1/12 Mechanical Interlock u u u u Fungus Proofing (ref. page -91) u u u u u u u u u Type 1 Indoor Surface u u u u u u u u Type 1 Indoor, Flush u u u u u u u u Type 3R Outdoor-Rainproof u u u u u u u u BQ, BQH, HBQ QJ2, QJH2, QJ2-H CQD NGG For inches / millimeters conversion, see Application Data section. a 3-pole breakers only (factory installed only). b Type CQD6 CSA only. ccqd breakers are rated 14,000 KAIC at 480/2V. d HQJ2 breakers are also rated 208VAC. -10 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

11 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers General Purpose Breakers NEG HEG ED2 ED4 ED6 HED4 HHED6 CED6 Page AC Poles 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3 1, 2, 3 1 d, 2, 3 1, 2, 3 2, 3 2, 3 Amperes, Continuous Volts 50/60HZ 1-Pole 34 g 34 g Pole 3-Pole 600/34 600/ UL 120V 10, , V 85, ,000 10,000 65,000 65, ,000 e 100, ,000 2V 22,000 a 65,000 b 34V 30, V 35,000 65,000 18,000 25, ,000 65, ,000 Ratings Interrupt Rating 600V 22,000f 25,000 f 18,000 18, ,000 DC Symmetrical RMS Amperes 220/240V Icu 85, ,000 65,000 Ics 42,000 50,000 1,000 IEC 94-2 Icu 40,000 0,000 35, /415V 50/60HZ Ics 20,000 35,000 19, V Icu 18,000 Ics 15,000 2-Pole, 250V DC Interrupting Ratings 35,000 42,000 5,000 30,000 30,000 30,000 30,000 3-Pole, 500V DC Interrupting Ratings c 18,000 50,000 H height Dimensions in 1-Pole inches Width 2-Pole Pole Pole Depth Thermal and Fixed Magnetic Trip u u u u u u u u Overcurrent Thermal and Adjustable Magnetic Trip Devices Adjustable Magnetic Trip only u u Motor Circuit Protector Accessories & Modifications Individual Enclosures Molded Case Switch u u u u u u Undervoltage Trip u u u u u u u u Shunt Trip u u u u u u u u Auxiliary Switch u u u u u u u u Alarm Switch u u u u u u u u Mechanical Interlock u u Rear Connection Studs u u u u u u u u Electric Motor Operator u u u u u u Plug-In Mounting Assembly (3-4 Pole Only) u u u u u u u u Fungus Proofing (ref. page -91) u u u u u u u u Type 1 Indoor Surface u u u u u u Type 1 Indoor, Flush u u u u u u Type 3R Outdoor-Rainproof u u u u u u Type Flammable Gas Atmosphere u u u u u Type 9 Combustion Dusttight u u u u u Type 5, 12 Lint, Fine Dust, Oils, Coolants u u u u u u Type 12K Semi-Dusttight u u u u u u NEG, HEG ED, HED, HHED For inches / millimeters conversion, see Application Data section. a 1-pole only. b A: 25,000 AIR at 2V AC/15-30A: 65,000 AIR at 2V AC. c For DC UPS system application. d Single pole ED6 (15 30A) 30kA, (35 100A) 18 ka. CSA Only. e Single pole HED4, 15-30A: 65,000 AIR at 240V AC; single pole HED4, A: 25,000 AIR at 240V AC. f NEG and HEG breakers are rated at 600/34V. g 1-pole NEG breaker is rated 240V, 2V and 34V. 1-pole HEG breaker is rated 240V, 2V and 34V. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -11

12 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers General Purpose Breakers FD6A, HFD6, HHFD6, JD6-A, HJD6-A, HHJD6-A, FXD6A HFXD6 HHFXD6 CFD6 JXD2-A JXD6-A HJXD6-A HHJXD6-A CJD6 Page Ratings AC DC Poles 2, 3 2, 3 2, 3 3 2, 3 2, 3 2, 3 2, 3 3 Amperes, Continuous Volts 50/60HZ Interrupt Rating Symmetrical RMS Amperes 2-Pole Pole 240V 65, , , ,000 65,000 65, , , ,000 UL 480V 35,000 65, , ,000 35,000 65, , , /240V 600V 22,000 25,000 25, ,000 25,000 35,000 50, ,000 Icu 65, ,000 65, ,000 Ics 33,000 50,000 33,000 50,000 IEC /415V Icu 35,000 65,000 40,000 65,000 50/60HZ Ics 18,000 33,000 20,000 33, V Icu Ics 2-Pole 250V DC Interrupting Ratings 30,000 30,000 50,000 30,000 30,000 30,000 50,000 3-Pole, 500V DC Interrupting Ratingsa 18,000 25,000 50,000 25,000 35,000 50,000 H height Dimensions in inches Width 2-Pole 3-Pole Depth Thermal and Fixed Magnetic Trip Thermal and Adjustable Magnetic Trip u u u u u u u u u Overcurrent Adjustable Magnetic Trip Only u u u u Devices Motor Circuit Protector Accessories & Modifications Individual Enclosures Molded Case Switch u u u u u Undervoltage Trip u u u u u u u u u Shunt Trip u u u u u u u u u Auxiliary Switch u u u u u u u u u Alarm Switch u u u u u u u u u Mechanical Interlock u u u u u u u u u Rear Connection Studs u u u u u u u u u Electric Motor Operator u u u u u u u u u Plug-In Mounting Assembly u u u u u u u u u Fungus Proofing (ref. page -91) u u u u u u u u Type 1 Indoor Surface u u u u u u u u u Type 1 Indoor, Flush u u Type 3R Outdoor-Rainproof u u u u u u u u Type Flammable Gas Atmosphere u u u u u u u Type 9 Combustion Dusttight u u u u u u u Type 5, 12 Lint, Fine Dust, Oils, Coolants u u u u u u u u u Type 12K Semi-Dusttight u u u u u u u For inches / millimeters conversion, see Application Data section. a For DC UPS application. -12 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

13 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers General Purpose Breakers LD6, HLD6, HHLD6, LMD6, HLMD6, MD6, HMD6, LXD6 HLXD6 HHLXD6 CLD6 LMXD6 HLMXD6 MXD6 HMXD6 CMD6 Page Poles 2, 3 2, 3 2, 3 3 2, 3 2, 3 2, 3 2, 3 3 Ratings AC DC Amperes, Continuous Volts 50/60 HZ 2-Pole 3-Pole V 65, , , ,000 65, ,000 65, , ,000 UL 480V 35,000 65, , ,000 50,000 65,000 50,000 65, , V 25,000 35,000 50, ,000 25,000 50,000 25,000 50,000 65,0001 Interrupt Rating Icu 65, ,000 65, ,000 65, ,000 Symmetrical RMS 220/240V Amperes Ics 33,000 50,000 33,000 50,000 33,000 50,000 IEC 94-2 Icu 40,000 65,000 40,000 65,000 40,000 65, /415V 50/60HZ Ics 20,000 33,000 20,000 33,000 20,000 33, V Icu 1 Ics 2-Pole 250V DC Interrupting Ratings 30,000 30,000 50, ,000 30,000 30,000 30,000 30, Pole, 500V DC Interrupting Ratingsa 35,000 50, ,000 50,000 25,000 50,000 50,000 H height Width Depth Thermal and Adjustable Magnetic Trip u u u u u u u u u Overcurrent Adjustable Magnetic Trip Only u u u u u u Devices Motor Circuit Protector Molded Case Switch u u u u u Accessories & Modifications Individual Enclosures Undervoltage Trip u u u u u u u u u Shunt Trip u u u u u u u u u Auxiliary Switch u u u u u u u u u Alarm Switch u u u u u u u u u Mechanical Interlock u u u u u u u u u Rear Connection Studs u u u u u u u u u Electric Motor Operator u u u u u u u u u Plug-In Mounting Assembly u u u u u u u Fungus Proofing (ref. page -91) u u u u u u u u u Type 1 Indoor Surface u u u u u u u u u Type 1 Indoor, Flush u Type 3R Outdoor-Rainproof u u u u u u u u Type 5, 12 Lint, Fine Dust, Oils, Coolants u u u u u u u u Type Flammable Gas Atmosphere u u u Type 9 Combustion Dusttight u u u u Type 12K Semi-Dusttight u u u u u u u u For inches / millimeters conversion, see Application Data section. a For DC UPS application. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -13

14 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers General Purpose Breakers ND6, HND6, PD6, d HPD6, d NXD6 HNXD6 CND6 PXD6 d HPXD6 d CPD6 d Page Poles 2, 3 2, Amperes, Continuous Volts 50/60 HZ 3-Pole V 65, , ,000 65, , ,000 UL 480V 50,000 65, ,000 50,000 65, , V 25,000 50,000 65,000 25,000 50,000 65,000 AC Ratings Interrupt Rating Icu 65, ,000 Symmetrical RMS 220/240V Ics 33, ,000 Amperes IEC 94-2 Icu 40, , /415V 50/60HZ Ics 20, , V Icu Ics 1 2-Pole 250V DC Interrupting Ratings 30, ,000 30,000 30,000 30,000 30,000 DC 3-Pole, 500V DC Interrupting Ratings a 25, ,000 50,000 25,000 50,000 50,000 Circuit breakers require Connect-all Height Dimensions in mounting block. Dimensions shown Width inches are for circuit breaker only. Depth Thermal and Adjustable Magnetic Trip u u u u u u Overcurrent Adjustable Magnetic Trip Only Devices Motor Circuit Protector Molded Case Switch u u u Undervoltage Trip u u u u u u Shunt Trip u u u u u u Auxiliary Switch u u u u u u Accessories & Alarm Switch u u u u u u Modifications Mechanical Interlock u u u u u u Rear Connections Studs u u u Electric Motor Operator u u u u u u Plug-in Mounting Assembly u u u Fungus Proofing (ref. page -91) u u u u u u Mounting Block (required) u u u Type 1 Indoor Surface u u u u u u Type 1 Indoor, Flush Type 3R Outdoor-Rainproof u u u Individual Enclosures Type Flammable Gas Atmosphere u u u Type 9 Combustion Dusttight Type 5, 12 Lint, Fine Dust, Oils, Coolants Type 12K Semi-Dusttight u u u For inches / millimeters conversion, see Application Data section. a For DC UPS application. b 2-pole design. c 3-pole design. d Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. -14 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

15 Molded Case Circuit Breakers Thermal-Magnetic Trip Breakers & Electronic Trip Breakers General Purpose Breakers Solid State Trip Circuit Breakers RD6, a HRD6, a RXD6 a HRXD6 a SJD6 SHJD6 SCJD6 SLD6 SHLD6 SCLD6 Page Ratings Poles Amperes, Continuous Volts 50/60 HZ 3-Pole V 65, ,000 65, , ,000 65, , ,000 UL 480V 50,000 65,000 35,000 65, ,000 35,000 65, , V 25,000 50,000 25,000 35, ,000 25,000 35, ,000 AC Interrupt Rating Symmetrical RMS 220/240V Icu Ics Amperes IEC Icu 380/415V DC 50/60HZ Ics 500V Icu Ics 2-Pole 250V DC Interrupting Ratings 30,000 30,000 3-Pole, 500V DC Interrupting Ratings a 25,000 50,000 H height Dimensions in Width 3-Pole inches Depth Solid State Trip u u u u u u Thermal and Adjustable Magnetic Trip u u Overcurrent Adjustable Magnetic Trip Only Devices Motor Circuit Protector Molded Case Switch u Undervoltage Trip u u u u u u u u Shunt Trip u u u u u u u u Auxiliary Switch u u u u u u u u Accessories & Alarm Switch u u u u u u u u Modifications Mechanical Interlock u u u u u u u u Individual Enclosures Rear Connections Studs u u u u u u Electric Motor Operator u u u u u u u u Plug-In Mounting Assembly u u u u u u Fungus Proofing (ref. page -91) u u u u u u u u Mounting Block (required) u u Type 1 Indoor Surface u u u u u u u u Type 1 Indoor, Flush Type 3R Outdoor-Rainproof u u u u Type Flammable Gas Atmosphere u u u u Type 9 Combustion Dusttight u u u u Type 5, 12 Lint, Fine Dust, Oils, Coolants u u u u u u Type 12K Semi-Dusttight u u u u u u Selection For inches / millimeters conversion, see Application Data section. a Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -15

16 Molded Case Circuit Breakers Electronic Trip Breakers Selection Solid State Trip Circuit Breakers SMD6 SHMD6 SCMD6 SND6 SHND6 SCND6 SPD6 a SHPD6 a Page Poles Amperes, Continuous Volts 50/60HZ 3-Pole V 65, , ,000 65, , ,000 65, ,000 Ratings AC Interrupt UL 480V 50,000 65, ,000 50,000 65, ,000 50,000 65,000 Rating 600V 25,000 50,000 65,000 25,000 50,000 65,000 25,000 50,000 Symmetrical 380/415V Icu RMS IEC Ics Amperes 50/60HZ Icu 690V Ics height Dimensions in Width inches Depth Overcurrent Devices Solid State Trip u u u u u u u u Undervoltage Trip u u u u u u u u Shunt Trip u u u u u u u u Auxiliary Switch u u u u u u u u Alarm Switch u u u u u u u u Accessories & Mechanical Interlock u u u u u u u u Modifications Rear Connection Studs u u u u u u Electric Motor Operator u u u u u u u u Plug-In Mounting Assembly u u u u u u Fungus Proofing (ref. page -91) u u u u u u u u Type 1 Indoor Surface u u u u u u u u Type 1 Indoor, Flush Type 3R Outdoor-Rainproof u u u u u u Individual Enclosures Type Flammable Gas Atmosphere Type 9 Combustion Dusttight Type 5, 12 Lint, Fine Dust, Oils, Coolants u u u u u u Type 12K Semi-Dusttight u u u u u u For inches / millimeters conversion, see Application Data section. a Requires connect-all mounting block assembly. Dimensions shown are for circuit breaker. b Breaker has rating plugs which can be changed within each frame rating. -16 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

17 Molded Case Circuit Breakers Page Breaker Frame Family GG EG DG FG JG Continuous Amps A A A A 0 400A Poles 1, 2, 3 1, 2, 3, 4 2, 3 2, 3 2, 3 Max. Volts AC 600Y/34V 600Y/34V 600V 600V 600V Breaker Type NGG NEG HEG NDGA HDGA LDGA NFGA HFGA LFGA NJGA HJGA LJGA Interrupting Class N N h N H L N H L N H L 240Vac Interrupting UL 480Vac Rating RMS 600Vac 14 (600Y/34) Ratings Symmetrical 220/240Vac 65/33 85/43 100/50 65/65 100/5 200/150 65/65 100/5 200/150 65/65 100/5 200/150 Amperes l CU /l CS 380/415Vac 25/ /30 0/35 40/40 0/0 100/5 40/40 0/0 100/5 45/45 0/0 100/5 AC 50/60Hz 690Vac 12/6 12/6 12/6 12/6 12/6 12/6 12/6 15/8 15/8 DC 250Vdc (2-Pole) Interrupting 500Vdc (3-Pole) Ratings (UL) b 600Vdc (3-Pole) Pole 5.1H x 1W x 2.8D 5.5H x 1W x 3D Dimensions 2-Pole 5.1H x 2W x 2.8D 5.5H x 2W x 3D 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D in Inches 3-Pole 5.1H x 3W x 2.8D 5.5H x 3W x 3D 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D 4-Pole 5.5H x 4W x 3D Thermal-Magnetic u u u u u Electronic u u u Trip Unit Electronic with LCD u u u Information Interchangeable Trip Unit u u u Reverse Feed (w/non-interchangeable Trip) u u u u u Communications Capability u u u Molded Case Switch u u u u Specific Motor Circuit Protector u u u u Application Breakers 100% Rated u u 50 C Calibrated u Auxiliary Switch u u u u u Alarm Switch u u u u u Shunt Trip u u u u u Undervoltage Release u u u u Accessories & Mechanical Interlocks u u u u Modifications Electric Motor or Stored Energy Operator u u u u Rear Connecting Studs u u u u Plug-In Mounting Assy. w/trip Interlock u u u u Draw-Out Assembly u u u Handle Mechanism Options u u u u u NEMA 1 Indoor, Surface Mount u NEMA 1 Indoor, Flush Mount u NEMA 3R Outdoor, Rain Proof u Enclosures NEMA 4, 4X Stainless Steel u NEMA, 9 Hazardous Locations NEMA 12 Dust u Terminal Shields u u u u Distribution Lugs u u u u u Ground Sensor (Neutral Transformer) u u u a 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. b DC Interrupting Ratings are not applicable to electronic circuit breakers. Communications available via a COMPRO or COMMOD modules using Profibus or Modbus protocols. Consult Siemens for availability. Non-metallic NEMA 4X enclosure for NGG breakers. Special version, see page GG and EG are not VL family breakers and do not share common VL accessories. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -1

18 Molded Case Circuit Breakers Page Breaker Frame Family LG MG NG PG Continuous Amps A A A A Poles 2, 3 2, 3 2, 3 3 Max. Volts AC 600V 600V 600V 600V Breaker Type NLGB HLGB LLGB NMG HMG LMG NNG HNG LNG NPG HPG LPG Interrupting Class N H L N H L N H L N H L 240Vac Interrupting UL 480Vac Rating RMS 600Vac Ratings Symmetrical 220/240Vac 65/65 100/5 200/150 65/35 100/50 200/150 65/65 100/5 200/100 65/35 100/50 200/100 Amperes l CU /l CS 380/415Vac 45/45 0/0 100/5 50/50 0/0 100/5 50/25 0/35 100/50 50/25 0/35 100/50 AC 50/60Hz 690Vac 12/6 15/8 15/8 20/10 30/15 35/1 20/10 30/15 35/1 20/10 30/15 35/15 DC 250Vdc (2-Pole) Interrupting 500Vdc (3-Pole) Ratings (UL) c 600Vdc (3-Pole) Dimensions 2-Pole 11H x 5.5W x 4.2D 16H x.5w x 4.D 16H x 9W x 6.2D in Inches 3-Pole 11H x 5.5W x 4.2D 16H x.5w x 4.D 16H x 9W x 6.2D Thermal-Magnetic u u u u Electronic u u u u Trip Unit Electronic with LCD u u u u Information Interchangeable Trip Unit u u u Reverse Feed (w/non-interchangeable Trip) u u u u Communications Capability a u u u u Specific Molded Case Switch u u u u Application Motor Circuit Protector u u u Breakers 100% Rated u u u u Auxiliary Switch u u u u Alarm Switch u u u u Shunt Trip u u u u Undervoltage Release u u u u Accessories & Mechanical Interlocks u u u u Modifications Electric Motor or Stored Energy Operator u u u u Rear Connecting Studs u u u u Plug-In Mounting Assy. w/trip Interlock u Draw-Out Assembly u u H handle Mechanism Options u u u u Terminal Shields u u u u Distribution Lugs Ground Sensor (Neutral Transformer) u u u u a Communications available via COMPRO or COMMOD modules using Profibus or Modbus protocol. b 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. c DC Interrupting Ratings are not applicable to electronic circuit breakers. LG frame maximum 500A. Special version, see page Special 600Vac 25kA version available, see page Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

Molded Case Circuit Breakers Reference Guide

Molded Case Circuit Breakers Reference Guide Molded Case Circuit Breakers Plug-In Breakers Panelboard Breakers QT QP, QPP QPH, QPPH HQP, HQPP HQPPH QPJ BL BLH HBL BQD, BQD NGB NEB HEB Page 1-25 1-27, 1-29 1-27, 1-29 1-24, 1-29 1-24, 1-29 1-29 -18-18

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers 600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers 600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers 600V Circuit Breakers Sentron ED Breakers 240V 480V 600V ED2 0KAIC ED4 65KAIC 8KAIC ED6 65KAIC 25KAIC 8KAIC -, 2- & 3-pole up to 25A for circuit protection up to 600 volt circuits (UL/CSA/IEC) General

More information

Enclosed Circuit Breakers

Enclosed Circuit Breakers Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,

More information

Enclosed Circuit Breakers

Enclosed Circuit Breakers Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,

More information

Enclosed Circuit Breakers Enclosures Type 1

Enclosed Circuit Breakers Enclosures Type 1 s Type Selection Figure Figure Figure Type K.O. Number Maximum Weight Fig. Breaker of Current Catalog List Lb./Ship. (inches) 6 Plcs. Plcs. No. Frame Poles Rating Number Price $ Package A B C D E F G H

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers 600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers 600V Circuit Breakers Sentron ED Breakers 240V 480V 600V ED2 10KAIC ED4 65KAIC 18KAIC ED6 65KAIC 25KAIC 18KAIC 1-, 2- & 3-pole up to 125A for circuit protection up to 600 volt

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers mmmmmmmm Q5A Frame SLCTION Ordering Instructions All BQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix 'L' to catalog number. Lugs will be supplied at no

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers SPEEDFAX TM 20 Section Dual Function Circuit Breaker Scan to connect online to the most up-todate version of this Section of SPEEDFAX. NGB Circuit Breakers QR Circuit Breakers c o n t e n t s What s New

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A

More information

Section 6. Molded Case Circuit Breakers. Contents. VLThermal Mag and Electronic Circut Breakers What s New in Circuit Breakers

Section 6. Molded Case Circuit Breakers. Contents. VLThermal Mag and Electronic Circut Breakers What s New in Circuit Breakers Section m Molded Case Circuit Breakers /3 Applicable Standards /3 Reference Guides /5 Panelboard Mtg Circuit Breakers BL, GFCI, AFCI /13 BQ 125A Frame, Switching Neutral, DIN Rail /17 QJ 225A Frame /19

More information

Enclosed Circuit Breakers

Enclosed Circuit Breakers s Type Selection Figure Figure Figure Type K.O. Fig. Breaker of Current Catalog Lb./Sip. Plcs. Plcs. No. Frame Poles Rating Number Package A B C D E F G H QP, QPH, HQP EMLS acg 8 5 8 8 5 QP, QPH, EMLS

More information

POWER PRODUCT Molded Case Circuit Breakers Contents

POWER PRODUCT Molded Case Circuit Breakers Contents POWER PRODUCT Contents Introduction -2 Catalogue ing System -3 Reference Guides - Panelboard Mounting BL -13 GFCI, AFCI -1 BQ 12A Frame, Switching Neutral, DIN Rail -16 BQD, BQD6-18 QJ 22A Frame -19 CQD

More information

POWER PRODUCT Molded Case Circuit Breakers Contents

POWER PRODUCT Molded Case Circuit Breakers Contents POWER PRODUCT Molded Case Circuit Breakers Contents Introduction -2 Catalogue ing System -3 Reference Guides - Panelboard Mounting Circuit Breakers BL -13 GFCI, AFCI -1 BQ 12A Frame, Switching Neutral,

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating

More information

POWER PRODUCT Molded Case Circuit Breakers Contents

POWER PRODUCT Molded Case Circuit Breakers Contents POWER PRODUCT Molded Case Circuit Breakers Contents Dual Function Circuit Breaker NGB Circuit Breakers What s New in Circuit Breakers -3-4 Catalogue Numbering System - -7 Reference Guides -8-17 Panelboard

More information

Enclosed Circuit Breakers

Enclosed Circuit Breakers Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,

More information

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards type P Lighting and Power Distribution Panelboards Specifications Main Breaker: 400A Maximum Main Lugs only: 400A Maximum Voltages: 480Y/277V AC Maximum 250V DC Maximum 3Ø3W, 3Ø4W, Ø3W, Ø2W General P panelboards

More information

a Alternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens.

a Alternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens. 11 PANELBOARDS Panelboards P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

Ampere Connectors Suitable for Copper or Aluminum 800 (3) - #3/0 AWG-500 Kcmil 1000 (4) - #3/0 AWG-500 Kcmil 1200 (4) - #3/0 AWB-500 Kcmil

Ampere Connectors Suitable for Copper or Aluminum 800 (3) - #3/0 AWG-500 Kcmil 1000 (4) - #3/0 AWG-500 Kcmil 1200 (4) - #3/0 AWB-500 Kcmil Panelboards Type P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still a space saver

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

aalternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens.

aalternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens. Panelboards P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still a space saver with

More information

VL Circuit Breaker DG 150A frame

VL Circuit Breaker DG 150A frame VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,

More information

Section 8. Switchboards. Contents. Sentron SMP, FCI, FCII Switchboards Type SMP. Selection Construction Details Specification Type FCI, FCII

Section 8. Switchboards. Contents. Sentron SMP, FCI, FCII Switchboards Type SMP. Selection Construction Details Specification Type FCI, FCII Section Switchboards Contents Sentron SMP, FCI, FCII Switchboards Type SMP Features Selection Construction Details Specification Type FCI, FCII Features Selection Construction Details Specifications Protective

More information

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless

More information

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features 11 Panelboards Features Another innovation from Siemens is the P3 panel. It is a smaller, footprint distribution panel to fit a large number of applications that require more (or larger) branch devices

More information

UL 1008 Withstand and Close On Ratings

UL 1008 Withstand and Close On Ratings Power topic #5410785 Technical information from Cummins UL 1008 Withstand and Close On Ratings White Paper By Rich Scroggins, Technical Advisor Electrical distribution system design requires sizing equipment

More information

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13 Circuit Breakers Lug-In/Lug-Out with INSTA-WIRE 03/06/3 All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix L to catalog number. Consult Siemens

More information

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic,

More information

RXT. Model: Model RXT Automatic Transfer Switch

RXT. Model: Model RXT Automatic Transfer Switch Model: RXT Automatic Transfer Switch -- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models

Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models Model: RXT Automatic Transfer Switch 100 - Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service

More information

RXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Available Models. Automatic Transfer Switch Amps

RXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Available Models. Automatic Transfer Switch Amps Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator

More information

RXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Automatic Transfer Switch Amps

RXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Automatic Transfer Switch Amps Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator

More information

Panelboards 11 PANELBOARDS. Unassembled. Reference. Catalog Numbering System. Branch Breakers

Panelboards 11 PANELBOARDS. Unassembled. Reference. Catalog Numbering System. Branch Breakers Panelboards Unassembled ing System Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally feed-thru lugs, or a subfeed circuit breaker up

More information

Selection and application guide. Panelboards P1 thru P5.

Selection and application guide. Panelboards P1 thru P5. Selection and application guide Panelboards P1 thru P5 www.usa.siemens.com/panelboards 1 SECTION Contents PAGE Introduction 2 General Specifications 3-5 Catalog Numbering System 6 A detailed Table of

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models

Model: RXT. Model RXT Automatic Transfer Switch. Standard Features. Standard Interface Board. Available Models Model: RXT Automatic Transfer Switch 100 - Amps Covers have been removed for illustration. Available Models D 100,, and amp standard and service entrance models are available. D 150 and 300 amp service

More information

POWER PRODUCT Panelboards Contents

POWER PRODUCT Panelboards Contents POWER PRODUCT Panelboards Contents Features, Reference Guide & General Specifications -2-7 Factory Assembled Panelboard Coding System -8 Type P1 Specifications -9 - Unassembled panelboard -11-12 Main Lug

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH

More information

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS)

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS) // Automatic Transfer Switches Standard Any Breaker Rated Available Controllers D Decision-Makerr MPAC 1200 D Decision-Makerr MPAC 1500 Ratings Current Voltage, Frequency 30--4000 amps 150--4000 amps 150--4000

More information

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS)

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS) // Automatic Transfer Switches Standard Any Breaker Rated Available Controllers D Decision-Makerr MPAC 1200 D Decision-Makerr MPAC 1500 Ratings Current Voltage, Frequency 30--4000 amps 150--4000 amps 150--4000

More information

Sentron Molded Case Circuit Breakers Series Connected Short Circuit Ratings

Sentron Molded Case Circuit Breakers Series Connected Short Circuit Ratings Sentron Molded Case Circuit Breakers Series Connected Short Circuit Ratings The term Series Connected Short Circuit Rating refers to the application of series circuit breakers in a combination that allows

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B210 15 B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (1V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 B1 B1H B1HH B1 B1H B1HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH 40 B140 B140H B140HH

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Siemens SPD TOTAL HOME SURGE PROTECTION

Siemens SPD TOTAL HOME SURGE PROTECTION TOTAL HOME SURGE PROTECTION All Appliances Coax Phone Purge damaging surges at the source and protect home electronics with Siemens SPD - Home Entertainment - Kitchen & Laundry Appliances - Home Security

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.

More information

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection Table of Contents Introduction... 2 Need for Circuit Protection... 4 Types of Overcurrent Protection Devices... 6 Circuit Breaker Design... 9 Types of Circuit Breakers... 20 Circuit Breaker Ratings...

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

Introduction. Upon completion of Molded Case Circuit Breakers you will be able to: Explain the need for circuit protection

Introduction. Upon completion of Molded Case Circuit Breakers you will be able to: Explain the need for circuit protection Table of Contents Introduction...2 Need for Circuit Protection...4 Types of Overcurrent Protective Devices...8 Circuit Breaker Design...11 Types of Circuit Breakers...24 Circuit Breaker Ratings...29 Time-Current

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A Catalog LV 1 Add-On October 2006 sentron CIRCUIT-BREAKERS 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 00 A Related catalogs Contents Low-Voltage Controls and Distribution SIRIUS

More information

Revised P1 Panelboards

Revised P1 Panelboards Panelboards (Introduced January 2015) Data Sheet The Panelboards are now available in both Feed-thru (FT) and Non-Feed-thru (NFT) variations. There is a savings of 6 of box height when a NFT version is

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

SPEEDFAX TM 2011 Molded Case Circuit Breakers. Contents. Residential L Commercial L Industrial. Revised 01/10/16

SPEEDFAX TM 2011 Molded Case Circuit Breakers. Contents. Residential L Commercial L Industrial. Revised 01/10/16 SPEEDFAX TM 2011 Molded Cse Circuit Brekers 01/10/16 Contents Wht s New in Circuit Brekers -3-4 Federl Specifictions Clssifiction -5 Ctlog Numbering System -6-8 Reference Guides -9-18 Lod Center Brekers

More information

2.3. Molded Case Circuit Breakers. Contents

2.3. Molded Case Circuit Breakers. Contents .3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Installation Instructions

Installation Instructions Item: I-T-E Circuit Breaker Motor Operator For use with: See Table Below Page 1 of 6 Siemens Energy & Automation, Inc. Bellefontaine, Ohio 43311 U.S.A. DESCRIPTION severe injury. installing or servicing.

More information

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950. Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL File E14900 Project 98NK40464 January 11, 1999 REPORT on MOTOR CONTROLLERS MAGNETIC Siemens Energy & Automation Inc. Batavia, IL Copyright 1999 Underwriters Laboratories Inc. Underwriters Laboratories

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

VL Circuit Breakers. MG 800A Frame, VL Series. Selection/Dimensions. Revised 03/08/13. Dimensions, inches (mm) Interrupting Ratings

VL Circuit Breakers. MG 800A Frame, VL Series. Selection/Dimensions. Revised 03/08/13. Dimensions, inches (mm) Interrupting Ratings MG 800A Frame, VL Series Revised 03/08/13 /Dimensions Ordering Information Complete Assembled Breaker A complete factory assembled MG breaker includes the frame, trip unit, and standard line and load lugs,

More information

Thermal-Magnetic For Mining Applications Class 600

Thermal-Magnetic For Mining Applications Class 600 Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information