Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C
|
|
- Sylvia Goodwin
- 5 years ago
- Views:
Transcription
1 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units. 70 ka at 45 Vac and 65 ka at 480 Vac RG Circuit /Frame Frame RG Performance at 480 Vac H = 65 kaic C = 00 kaic Poles 3 = Three 4 = Four s 60 = = = 500 RG Circuit /Frame for OPTIM 60 and 90 RGH 65K RGC 00K Poles 3 = Three 4 = Four RG H ZG E C Trip Unit 33 = 30+ Electronic LS 3 = 30+ Electronic LSI 35 = 30+ Electronic LSG 35B = 30+ Electronic LS(A), GFA, no trip 36 = 30+ Electronic LSIG 36B = 30+ Electronic LSI(A), GFA, no trip 38 = 30+ Electronic ALSI w/ Maintenance Mode 39 = 30+ Electronic ALSIG w/ Maintenance Mode 39B = 30+ Electronic ALSI(A) w/ Maintenance Mode and GFA, no trip RGH 3 6 T33 W s 6 = = = 500 Trip Function Digitrip 60 T6 = LI T6 = LSI T63 = LS T64 = LIG T65 = LSG T66 = LSIG Digitrip 90 T9 = LI T9 = LSI T93 = LS T94 = LIG T95 = LSG T96 = LSIG Blank = 80% rated C = 00% rated (except 500A) Terminations M = Metric tapped line/load conductors E = Imperial tapped line/load conductors W = No terminals Feature Blank = No feature B0 = High load alarm B = Ground fault ZG = Zone selective interlocking Modification Suffix R = Ground fault remote RES trip E = 00% protection (new design 30) RES trip unit P = 00% prot. neut. 4P RES trip unit V3 = Electronic trip without ambient temperature marked on trip unit W = w/o terms K = Molded case switch. Volume 4Circuit Protection CA EApril 04 V4-T-7
2 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Product Selection 70 ka at 45 Vac and 65 ka at 480 Vac RGH with Digitrip 30+ High Interrupting CapacityU e 690 Vac, 70 ka I cu at 45 Vac at 40 C 00 ka at Both 45 Vac and 480 Vac RGH with Digitrip 30+ High Interrupting CapacityU e 690 Vac, 70 ka I cu at 45 Vac Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A For SCR application, use 000 ampere frame. Order terminals separately. Mounting hardware not included. 3 Ground fault equipped trip units available with remote indicating panel. Add R to catalog number, for example, RGH36035RW. 4 Unprotected left pole neutral. Add P to catalog number for 00% protected left pole neutral, add E for 60% protected, for example, RGH46033PW, RGH46033EW. RG MCCBs have English threading on line and load conductors. Use suffix M for metric threading. V4-T-7 Volume 4Circuit Protection CA EApril x I n 00 00A Neutral CT for LSG and LSIG RGH36033E RGH3603E RGH36035E RGH36036E RGFCT60A RGH30033E RGH3003E RGH30035E RGH30036E RGFCT00A RGH35033E RGH3503E RGH35035E RGH35036E RGFCT50A at 40 C Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A RGH46033E RGH4603E RGH40033E RGH4003E RGH45033E RGH4503E 8 x I n 00 00A
3 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) ka at Both 45 Vac and 480 Vac RGC with Digitrip 30+ Very High Interrupting CapacityU e 690 Vac, 00 ka I cu at 45 Vac at 40 C RGC with Digitrip 30+ Very High Interrupting CapacityU e 690 Vac, 00 ka I cu at 45 Vac, continued Molded Case Switches 5 Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A 8 x I n 00 00A Neutral CT for LSG and LSIG RGC36033E RGC3603E RGC36035E RGC36036E RGFCT60A RGC30033E RGC3003E RGC30035E RGC30036E RGFCT00A RGC35033E RGC3503E RGC35035E RGC35036E RGFCT50A at 40 C Circuit Frame Including Digitrip RMS 30 Electronic Trip Unit with Adjustable Plugs L Adjustable Long Delay Pickup (By Adjustable Plug) S Adjustable Short Delay Pickup with Fixed Short Delay Time (I t Response) or Adjustable Short Delay Time (Flat Response) I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous G Adjustable with Adjustable (Flat Response) LS LSI LSG 3 LSIG 3 8 x I n 8 x I n 8 x I n 00 00A RGC46033E RGC4603E RGC40033E RGC4003E RGC45033E RGC4503E RGK360KSE RGK300KSE RGK460KSE RGK400KSE 8 x I n 00 00A For SCR application, use 000 ampere frame. Order terminals separately. Mounting hardware not included. 3 Ground fault equipped trip units available with remote indicating panel. Add R to catalog number, for example, RGH36035RW. 4 Unprotected left pole neutral. Add P to catalog number for 00% protected left pole neutral, add E for 60% protected, for example, RGH46033PW, RGH46033EW. 5 Molded case switch will trip above 7,500 amperes. RG MCCBs have English threading on line and load conductors. Use suffix M for metric threading.. Volume 4Circuit Protection CA EApril 04 V4-T-73
4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG with Digitrip 60 and 90 at 40 C Long Delay Pickup Long Delay Time Instantaneous Circuit Frame Including Digitrip RMS 60 and 90 Electronic Trip Unit with Plugs Order as Individual Component L Adjustable Long Delay Pickup (I r ) with Adjustable Long Delay Time S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I t or Flat Response) I Adjustable Instantaneous Pickup G Adjustable with Adjustable Ground Fault Time Delay (I t or Flat Response) Order terminals separately. Mounting hardware not included. Not to exceed 00 ampere ground fault pickup. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required. V4-T-74 Volume 4Circuit Protection CA EApril 04 Digitrip RMS Interchangeable Plug (Order as Individual Component) LI LS LSI LIG LSG LSIG Fixed Plug 4 Seconds 6 x I r 6 x M and M 0.5 I.0 n 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M RGH with Digitrip 60 High Interrupting CapacityU e Max. 690 Vac, 70 ka I cu at 45 Vac RGH36T6WP44 RGH36T63WP44 RGH36T6WP44 RGH36T64WP44 RGH36T65WP44 RGH36T66WP RP6R6A RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A RGH30T6WP49 RGH30T63WP49 RGH30T6WP49 RGH30T64WP49 RGH30T65WP49 RGH30T66WP RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A RGH35T6WP53 RGH35T63WP53 RGH35T6WP53 RGH35T64WP53 RGH35T65WP53 RGH35T66WP RP6R5A RP6R5A RP6R5A50 RGC with Digitrip 60 Very High Interrupting CapacityU e Max. 690 Vac, 00 ka I cu at 45 Vac RGC36T6WP44 RGC36T63WP44 RGC36T6WP44 RGC36T64WP44 RGC36T65WP44 RGC36T66WP RP6R6A RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A RGC30T6WP49 RGC30T63WP49 RGC30T6WP49 RGC30T64WP49 RGC30T65WP49 RGC30T66WP RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A RGC35T6WP53 RGC35T63WP53 RGC35T6WP53 RGC35T64WP53 RGC35T65WP53 RGC35T66WP RP6R5A RP6R5A00 Includes 500A rating plug 500 RP6R5A50
5 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG with Digitrip 60 and 90, continued at 40 C Long Delay Pickup Long Delay Time Instantaneous Order terminals separately. Mounting hardware not included. Not to exceed 00 ampere ground fault pickup. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required. Circuit Frame Including Digitrip RMS 60 and 90 Electronic Trip Unit with Plugs Order as Individual Component L Adjustable Long Delay Pickup (I r ) with Adjustable Long Delay Time S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I t or Flat Response) I Adjustable Instantaneous Pickup G Adjustable with Adjustable Ground Fault Time Delay (I t or Flat Response). Digitrip RMS Interchangeable Plug (Order as Individual Component) LI LS LSI LIG LSG LSIG Fixed Plug 4 Seconds 6 x I r 6 x M and M 0.5 I.0 n 4 Seconds 6 x I r 4 Seconds 6 x I r 6 x M and M 4 Seconds 6 x I r 6 x M and M x In 4 Seconds 6 x I r x In 4 Seconds 6 x I r 6 x M and M x In RGH with Digitrip 90 High Interrupting CapacityU e Max. 690 Vac, 70 ka I cu at 45 Vac RGH36T9WP44 RGH36T93WP44 RGH36T9WP44 RGH36T94WP44 RGH36T95WP44 RGH36T96WP RP6R6A RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A RGH30T9WP49 RGH30T93WP49 RGH30T9WP49 RGH30T94WP49 RGH30T95WP49 RGH30T96WP RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A RGH35T9WP53 RGH35T93WP53 RGH35T9WP53 RGH35T94WP53 RGH35T95WP53 RGH35T96WP RP6R5A RP6R5A00 Includes 500A rating plug 500 RP6R5A50 RGC with Digitrip 90 Very High Interrupting CapacityU e Max. 690 Vac, 00 ka I cu at 45 Vac RGC36T9WP44 RGC36T93WP44 RGC36T9WP44 RGC36T94WP44 RGC36T95WP44 RGC36T96WP RP6R6A RP6R6A00 00 RP6R6A0 50 RP6R6A5 Includes 600A rating plug 600 RP6R6A RGC30T9WP49 RGC30T93WP49 RGC30T9WP49 RGC30T94WP49 RGC30T95WP49 RGC30T96WP RP6R0A00 00 RP6R0A0 50 RP6R0A5 600 RP6R0A60 Includes 000A rating plug 000 RP6R0A RGC35T9WP53 RGC35T93WP53 RGC35T9WP53 RGC35T94WP53 RGC35T95WP53 RGC5T96WP RP6R5A RP6R5A00 Includes 500 A rating plug 500 RP6R5A50 Volume 4Circuit Protection CA EApril 04 V4-T-75
6 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Accessories Selection Guide and Ordering Information Line and Load Terminals R-Frame circuit breakers use Cu/Al terminals as standard and copper only terminals as an option. Specify if factory installation is required. Must have terminals for 00% rated and or freeze testing requirements. Line and Load Terminals s Terminal Body Material Wire RG Rear Connector Exploded View AWG/kcmil Wire Range/ of Conductors TA000RD Wire Terminal Note: Order one TA000RDM kit per three poles. number includes bus connection, terminals and hardware for either line side or load side of three-pole breaker. Metric Wire Range mm V4-T-76 Volume 4Circuit Protection CA EApril 04 Hardware Wire Terminals 600 Aluminum Cu/Al Metric (4) TA600RDM 600 Copper Cu Metric 600 (4) T600RDM 000 Aluminum Cu/Al Metric 600 (6) TA000RDM Rear Connectors 000 Copper Metric B06RDM 000 Copper Metric B06RDLM 500 Copper Metric B500RDM Conductor (Viewed from Rear of Circuit and Cut Away for Clarity) Rear Connector (Cu) B06RDM B06RDLM (For 00% Application) (For 600A and 000A Frames) B500RDM for 500A Line/Load Conductors Conductor (Viewed from Front of Circuit ) Securing Hardware Securing Hardware Cu Only Terminal T600RDM 3 (For 600A Frame Only) OR Al/Cu Terminal TA600RDM 3 (For 600A Frame Only) Base Mounting Hardware Supplied by customer. Handle Extension Included with breaker. Additional handle extensions are available. Handle Extension Description Single handle extension HEX6 Order one per polesingle terminals individually packed. Order one TA000RD kit per three poles. number includes bus connection, terminals and hardware for either line side or load side of three-pole breaker. 3 For use with 500A Frame. Do not order separately unless for replacement purposes. Included in breaker carton when 500A frame is ordered. RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
7 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Accessories Allowable Accessory Combinations Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles in the circuit breaker. RG-Frame Accessories Legend Applicable in indicated pole position May be mounted on left or right polenot both Accessory available/modification available Note Contact Eaton.. Reference Three-Pole Four-Pole Description Page Left Center Right Left Center Right Neutral Internal Accessories (Only One Internal Accessory Per Pole) Alarm lockout (Make/Break) V4-T-04 Auxiliary switch (A, B) V4-T-04 Auxiliary switch (A, B) V4-T-04 Auxiliary switch and alarm switch combination V4-T-04 Shunt tripstandard V4-T-04 Undervoltage release mechanism V4-T-05 External Accessories Base mounting hardware V4-T-76 Padlockable handle lock hasp V4-T-0 Key interlock kit V4-T-0 Electrical operator V4-T-0 Handle mechanisms V4-T-407 Handle extension V4-T-76 Digitrip 30 test kit V4-T-0 Modifications (Refer to Eaton) Moisture fungus treatment V4-T-00 Freeze-tested circuit breakers Marine/naval application, UL 489 Supplement SA and SB Volume 4Circuit Protection CA EApril 04 V4-T-77
8 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Technical Data and Specifications UL 489/CSA Interrupting Capacity s Interrupting Capacity (ka Symmetrical s) Circuit Volts AC (50/60 Hz) RGH 3, RGC 3, IEC 947- Interrupting Capacity s Interrupting Capacity (ka Symmetrical s) Circuit Volts AC (50/60 Hz) RGH 3, 4 I cu I cs RGC 3, 4 I cu I cs Utilization Category A circuit breakers. See Page V4-T-70 for trip unit specifications. V4-T-78 Volume 4Circuit Protection CA EApril 04
9 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Dimensions and Weights Approximate Dimensions in Inches (mm) RG-Frame Width Height Depth (393.7) 6.00 (406.4) 9.75 (47.7) (508.0) 6.00 (406.4) 9.75 (47.7) 4.50 (368.3) 0.6 R (4.) 9.70 (46.4) 5.0 (9.5) 4 Holes 0.44 Dia. (.) Front Cover Cutout C L 7.5 (84.) 6.57 (66.9) 3.3 (333.5) C L Handle 7.75 (96.9) Approximate Shipping Weight in Lbs (kg) RG-Frame Complete 5.00 (38.0) 6.00 (406.4) Three-Pole Four-Pole 600 s RGH, RGC 0 (46.3) 35 (6.) 000 s RGH, RGC 0 (46.3) 35 (6.) 500 s RGH, RGC 35 (6.) 8 (8.6) Front View 3-Pole 5.50 (393.7) 8.5 (09.6) Side View 9.00 (8.6).5 (57.).44 R (.) Tee Connectors May Be Rotated (7.5) (330.) Volume 4Circuit Protection CA EApril 04 V4-T-79
2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationTable Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationL-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600
January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC
More information2.3. Molded Case Circuit Breakers. Contents
.3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationTechnical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs
-14 1 Amperes November 08 Eaton s Cutler-Hammer EG Product Description EG breaker is HACR rated. Technical Data and Specifications Table -6. UL 489/IEC 947-2 Interrupting Capacity Ratings Circuit Interrupting
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationL-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W
July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
More informationMolded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.
Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More informationVL Circuit Breaker DG 150A frame
VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,
More informationVL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable
VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic,
More informationSeries G Moulded Case. Circuit Breakers. Series G Moulded Case Circuit Breakers 1
1 Series G Moulded Case Circuit Breakers Description Series G Globally Accepted Breaker General Information........................................... 2 Product Line Overview.........................................
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Series G Circuit Breakers.1 Introduction Product Overview......................................... V4-T- Typical Applications........................................ V4-T-
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
15 0 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased performance in considerably less space than
More informationSupplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents
-1 May 008 Circuit Breakers & Supplementary Protectors Contents Description Page Series C vs. Series G Typical Applications........................................... - Series G Globally Accepted Breaker
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationBulletin 140U R-Frame Molded Case Circuit Breakers
R-Frame Molded Case Circuit Breakers Selection Guide Product Selection Product Selection 2500 A, R-Frame UL 489 Note: Terminal box lugs must be ordered separately. CSA 22.2, No. 5 IEC 60947-2 CE KEMA-KEUR
More information2.2. Molded Case Circuit Breakers. Contents. Motor Circuit Protectors (MCP)
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com. Motor Circuit 480 Vac, Protectors Motor Circuit Protectors () Contents V4-T-80 Volume
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More informationSeries G Moulded Case Circuit Breakers A for IEC & NEMA Applications
15 0 A for IEC & NEMA Applications Product Focus World-class accessories include: Q Circuit breaker W Thermal-magnetic trip unit, integrated on E Frame E Magnetic only trip unit, integrated on E Frame
More information30 ma Ground Fault (Earth Leakage) Modules. Product Description
August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton
More informationCutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed
More informationBULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE
BULLETIN 140U SELECTION GUIDE Product Overview Bulletin 140U 15 1200 A Thermal-Magnetic 15 800 A Electronic 70 1200 A LS Long Time/Short Time LSI Long Time/Short Time/High Instantaneous LSG Long Time/Short
More informationMolded Case. Circuit Breakers. Molded Case Circuit Breakers Contents
January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................
More informationInterrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F
-220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000
More informationCutler-Hammer. January 2001
Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationTable Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
-22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,
More informationPanelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description
.5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationMolded Case Circuit Breakers
SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationMolded Case Circuit Breakers
Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A
More informationInstallation Instructions for R-Frame Circuit Breakers and Molded Case Switches
Instruction Leaflet IL29C107N Effective January 2012 Supersedes IL29C107M 8/11 Installation Instructions for R-Frame Contents Description Page 1. Introduction........................... 2 2. Installation............................
More informationPowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers
PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationSwitchboards Instant Service
January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8
More informationUTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB
PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L
More informationSENTRON VL Series Product Specifications
SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped
More information2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationTYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS
om.c ww w.e lec tri ca lp ar tm an ua ls TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS Proven Technology with the Enhancements and Additional Ratings Our Customers Asked For
More informationMagnum IEC Low Voltage Air Circuit Breakers
Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven
More informationCOMMENTS: PLEASE SEE A/E COMMENTS
OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: BUILDING REFERENCE: SUBJECT: DISTRIBUTION SWITCHBOARDS - RESUBMITTED 1 TIME(S) DATE RECIEVED: v 07, 2014 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationMCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics
Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationS4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs
Molded case circuit breakers S3 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code
More informationSection 3: Molded Case Circuit Breakers
Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More information2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information
Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationModular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide
GE Industrial Solutions Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide TABLE OF CONTENTS Description Page 1.0 General Information...... 1 1.1 Protection..... 1 2.0 UL Listed Devices...
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationCutler-Hammer. January 2001
Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches MS50T3L M2N200T3L Ex9 Series - M na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationCutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers
Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationPower Breakers, Contactors and Fuses
Power Breakers, Contactors and Fuses Family.1 Power Circuit reakers Low Voltage Power Circuit Breakers........................... Magnum DS Low Voltage Power Circuit Breakers................ Magnum MDSL
More information.1 Power Circuit Breakers Power Circuit Breaker Low Voltage Power Circuit Breakers Product Overview Magnum Low Voltage Power Circuit Breakers for Glob
Power Breakers, Contactors and Fuses Family.1 Power Circuit Breakers Low Voltage Power Circuit Breakers.......................... Magnum DS Low Voltage Power Circuit Breakers................ Magnum MDSL
More informationUBW Family UL489 Molded Case Circuit Breakers
UBW Family UL489 Molded Case Circuit Breakers The UBW line offers the quality, realiablity and uncompromising protection that you have come to expect from WEG Molded Case Circuit Breakers UBW Series Product
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001
2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationThermal-Magnetic For Mining Applications Class 600
Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance
More informationCritical Power Switchboards. Selection and Application Guide
Selection and Application Guide Siemens RCIII (rear connected) switchboards utilizing Siemens Type SB Encased Breakers are a perfect solution for your critical power distribution needs. Whether your installation
More informationPower Breakers, Contactors and Fuses
Power Breakers, Contactors and Fuses Power Breakers, Contactors and Fuses Family.1 Power Circuit Breakers Low Voltage Power Circuit Breakers.......................... Magnum DS Low Voltage Power Circuit
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationLSIS UL MCCB & Accessory
LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................
More informationDetail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order
Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationMotor Circuit Breakers C4
Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationType MP-T Type MP-HT Type MP-MT
CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List
More informationMiniature Circuit Breakers
S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationPVGard 600 and 1000 Vdc solar photovoltaic circuit breakers
Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................
More information