Solenoid-driven Diaphragm Metering Pump

Size: px
Start display at page:

Download "Solenoid-driven Diaphragm Metering Pump"

Transcription

1 Solenoid-driven Diaphragm Metering ump

2 Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide discharge-volume range, various control functions...and many more. TACMINA's lineup of solenoiddriven diaphragm-type metering pumps, highly reliable and top-quality pumps, will answer all kinds of customers' chemical injection requirements.

3 Selection Guide by Application and Function Selection Guide Small Capacity Small Capacity S-size only S-size only Standard High-viscosity Boiler Z Manual Setting Multi Functions Z M T No-input Digital-input/output Timer Control Z Middle Capacity ZD ZI ZD Zi Advanced Functions ZD Zi4 Zi8 No-input Digital-input & Digital-Input/Output& Analog-Output Zi/ZD Large Capacity For Sodium Hypochlorite For Sodium Hypochlorite DCL Standard CL ARZ High-viscosity type CLZ Advanced Functions DCL CL CLZ AR Automatic Air-release Application DCL DCLM DCLT CL CLM CLT CLZ ARZ Digital-input/output Timer Control Digital-input/output Timer Control No-Input No-input Explanation & Corrosion-resistance Table Related Equipment & Option OTHER AR DCL/CL/CLZ

4 By Application For Injection of General Chemicals Series Small Capacity Z Manual Setting Small Capacity Multi Functions M T Middle Capacity ZD Zi Zi4 Zi8 Advanced Functions Large Capacity Advanced Functions w/ Relief Valve w/ Relief Valve Max. discharge volume Max. discharge pressure Max. allowable viscosity Signal ml/min L/h Ma bar Relief valve function Liquid-end material ma. s R R R R R R No-input M T Digital-input/output Timer Control ZD No-input Zi4 Digital-input & Zi8 /VDF/SUS /VDF/SUS /VDF Reference page GO to 5 GO to 7 GO to 13 GO to 17 For Injection of Boiler / High-pressure Series Small Capacity Z Manual Setting Small Capacity Multi Functions M T For Injection of High-viscosity Chemicals Small Capacity Multi Functions M T Middle Capacity ZD ZD Large Capacity Advanced Functions w/ Relief Valve w/ Relief Valve Max. discharge volume Max. discharge pressure Max. allowable viscosity ml/min L/h Ma bar Relief valve function Signal Liquid-end material ma. s R R No-input M T Digital-input/output Timer Control Digital-input/output M T Timer Control No-input Reference page GO to 5 GO to 7 GO to 7 GO to 13 GO to 17 1 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of *the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.

5 For Injection of Sodium Hypochlorite Series DCL Air Block In-Line Automatic Air-release DCL DCLM DCLT CL In-Line Automatic Air-release CL CLM CLT CLZ ARZ Automatic Air-release Selection Guide w/ Relief Valve w/ Relief Valve w/ Relief Valve Max. discharge volume Max. discharge pressure Max. allowable viscosity Signal ml/min L/h Ma bar ma. s Relief valve function Liquid-end material R 60R 100R R 60R 100R DCL Digital-input/output DCLM DCLT Timer Control 60 CL Digital-input/output CLM CLT Timer Control 100 Acrylic(MMA) R 60R 100R No-input Reference page GO to 21 GO to 23 By Function For details on each product, see the reference page for the respective model or "Explanation" on page 26. Series Small Capacity Middle Capacity Large Capacity For Sodium Hypochlorite Function Z M T ZD Zi4 Zi8 DCL CL DCLM CLM DCLT CLT CLZ ARZ Signal (No. of ports) Digital Input Output Analog Input ower supply to Flow Checker Stroke speed Manual Discharge volume ercentage ulse-input proportional control proportional control Interval operation Auto Timer control Control Count operation(batch control) External operation-signal control External stop-signal control 2-point Level Switch control* 1 ECO mode SAFE mode Relief valve function Alarm function Memory-read error (LCD display only) Tank-level alarm w/1-point Level Switch w/2-point Level Switch Error/ Alarm ulse-input error Analog-Input error (display only) (display only) Lower discharge-volume alarm* 2 Easy calibration function Momentary discharge-volume display function* 2 (display only) 1 When 2-point Level Switch is used * 2 When Flow Checker is used *

6 Small Capacity Z Manual Setting No-input w/ Relief Valve (R/60R/100R) (/60/100) Wide Voltage Range ower Supply AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V ( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. Simple Structure Minimum number of parts allows easy maintenance. Solenoid Discharge joint ump shaft Adjusting Dial for Easy Operation Manual adjustment from 15 to 0 pulses per minute ump head Diaphragm Water- & Dust-proof Specifications IEC standard: I65 or equivalent Avoid condensation and immersion in water. Outdoor Use Suction joint Stroke-speed adjustment dial Extensive Range of Liquid-end Materials For details, refer to the "Liquid-end Material" table on the following page. w/ Relief Valve w/ Relief Valve VTCE/ Material: Application example:transfer/ inject ion of general chemicals VTCET (for injection of boiler chemicals) Material: Application example:transfer/ inject ion of boiler chemicals w/ Relief Valve FTCE/FTCF/FTCT Material: VDF Application example:transfer/ inject ion of special chemicals(e.g. strong and mixed acids) 6TCT Material: Stainless steel(sus316) Application example:transfer/ inject ion of solutions/special chemicals

7 Specification: Z Specification Max. discharge volume* 1 Max. discharge pressure* 1 Stroke speed Stroke length ml/min L/h Ma bar 4 x 9 Discharge side Connection 6 x 8 (hose/tube: I.D x O.D) Suction side 1/4" x 3/8" Relief /air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Operation mode ower supply Weight Manual Rated voltage No. of phases/frequency Maximum current ower consumption R/ 60R/60 100R/100 VTCET VTCE FTCE FTCF FTCT 6TCT for injection of VTCE FTCE FTCF FTCT 6TCT VTCE FTCE FTCF FTCT 6TCT boiler chemicals x 8 1/4" x 3/8" 6 x 8 (FE) 1/4" x 3/8" (FE) x 8 (TFE) ( ) x 6 (nylon tube) 4 x to 0 strokes/min (dial setting) 6 x 11 6 x 8 1/4" x 3/8" Fixed at 1.0 mm 6 x 8 1/4" x 3/8" 4 x 6 (soft hose) 50 ma. s 6 x 8 (FE) 1/4" x 3/8" (FE) Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 2.0 A Max.: 200 VA/Ave.: 15 W 1.7 kg x 8 (TFE) 35 to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m Less than 85 db Setting stroke speed (15 to 0 strokes/min) w/ manual dial 6 x 11 6 x 8 1/4" x 3/8" (no freezing allowed) x 8 1/4" x 3/8" x 8 (FE) 6 x 8 1/4" x 3/8" (TFE) (FE) Z Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". Z R VTCE 4x9 W S JL (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug [for injection of general chemicals] R : ml/min (w/ Relief Valve) 60R : 60 ml/min (w/ Relief Valve) 100R : 100 ml/min (w/ Relief Valve) : ml/min 60 : 60 ml/min 100 : 100 ml/min [for injection of boiler chemicals] R : ml/min (w/ Relief Valve) : ml/min art VTCE FTCE FTCF FTCT 6TCT VTCET Liquid-end Material ump head Diaphragm Check ball O-ring Valve seat Joint Ball stopper 4 x 9 6 x 11 6 x 8 E/FE/TFE 1/4" x 3/8" E/FE 4 x 6 A W : Standard BW : Boiler S : Standard CE : CE marking-compatible for injection of ( boiler chemicals ) EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire Also refer to the "Corrosion-resistance Table" on page 26. VTCET VTCE FTCE FTCF FTCT 6TCT EDM EDM Fluoro-rubber Special fluoro-rubber EDM EDM VDF VDF TFE Ceramic Special fluoro-rubber Fluoro-rubber afulo Special fluoro-rubber TFE VDF TFE (valve stopper) EDM TFE SUS316 TFE SUS316 TFE (valve stopper) Item Accessory Hose/ Tube* 1 Relief /air-release hose* 1 Anti-siphon check valve * VTCE FTCE FTCF (R1/2) ower cable (2 m) is attached. R/60R/100R /60/100 FTCT 6TCT VTCET for injection of ( boiler chemicals ) 3 m Discharge side : 2 m Suction side : 1 m 1 m* 2 1 m* 2 (R1/2 or R3/8) (R1/2) Foot valve Ceramic weight * 2 Hose pump for air-release INSULOK for Relief /air-release hose 1 piece 1 piece ump mounting nuts/ bolts 2 sets (M5 x ) Operation manual 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. 2 This hose is already attached to R/60R/100R models. External Dimension (mm) R3 1 6 VTCE/ FTCE/FTCF/FTCT VTCET (A) B D C E G 110 (F) (A) B C D E (F) G The shape and dimensions differ slightly depending on the liquid-end material and connection type. The mounting pitch allows mounting from 87 to 110 mm.

8 Small Capacity Multi Functions M T Digital-input/output Timer Control Higher Safety Three types of safety functions that realize higher rank risk management SAFE mode for preventing abnormal pressure buildup While the discharge valve is closed, the liquid transfer force is controlled to prevent pressure buildup. Relief valve function for releasing abnormal pressure When the pressure exceeds the setting value, the relief valve operates automatically. Alarm function for notifying abnormal pressure When abnormal pressure builds up due to clogging of the pipes or while the discharge valve is closed, an alarm is emitted to warn this condition. To use the SAFE mode, set the stroke length to 100%. The SAFE mode is not available for -200, boiler type and high-pressure type. The function is disabled at the factory default setting. Standard type pump discharge pressure: 0.7Ma. Boiler-type pump discharge pressure: 1.5Ma. The Relief valve function cannot be selected for SUS type, high-viscosity type, and high-pressure type pumps. When the alarm function is used together with the SAFE mode, an alarm is emitted for pressure lower than the normal pressure. This function is disabled at the factory default setting. Safety function selection flow revents abnormal pressure buildup Outputs an alarm when abnormal pressure builds up Requires a discharge pressure of 0.7Ma minimum SAFE mode SAFE mode Alarm function Relief valve function Alarm function

9 Function correspondence table /M/T DCL/DCLM/DCLT CL/CLM/CLT General chemical model High-viscosity Boiler High-pressure Sodium hypochlorite R/60R/100R /60/ /100 R R/60R/100R /60/100 Relief valve function SAFE mode Alarm function ECO mode A circle ( ) is indicated for the corresponding function that can be set. A cross ( ) is indicated for the corresponding function that must not be set even though it istechnically possible. Superior Eco-friendly erformance Automatically cuts power-on time in accordance with the discharge pressure High pressure 1.0Ma The power of conventional pumps was always turned on for a specific period regardless of the discharge pressure. The ECO mode of pumps always monitors operation conditions and automatically shortens the power-on time during low-pressure operation in order to reduce power consumption. 1 cycle 1 cycle 1 cycle 1 cycle ower-on time to solenoid ower consumption reduction example: -60 model Operating pressure: 1.0Ma Number of strokes: 0 strokes/min. Average power consumption: 18W Low pressure 0.1Ma Operating pressure: 0.1Ma Number of strokes: 0 strokes/min. Average power consumption: 8W Up to 55% reduction of power consumption Optimal Ease of Use Operability Wide power supply range Water-&Dust-proof structure Easy maintenance Outdoor use Simple key operations and user interface enable intuitive operation. Operation can be performed using a voltage between AC100 and 240V (±10%). IEC standard: I65 or equivalent The liquid-end parts are easy to disassemble and replace by simply detaching four bolts. Flexible installation methods High-brightness display Wide variety of liquid-end components VDF Stainless steel For high-viscosity liquids The head can be moved in three directions. The high-brightness LED is clearly visible even in low-light environments. For boiler For highpressure liquids Acrylic for sodium hypochlorite

10 Wide-ranging Control Functions Realize Ideal Chemical Injection Systems Common functions M T Manual operation Strokes/minute control You can set the range between 1 and 0 strokes per minute in 1-stroke units. Discharge volume control ( only) You can set the range between 0.1 and the maximum discharge volume in 0.1mL-per minute units. External operation & stop control The pump can be turned on and off using a input signal from an external device. Relief valve side pipe (air purge hose) Level meter Chemical liquid tank Synchronous pulse control A single pulse can be output for a single pump operation. The output pulse can be input to a second pump to perform synchronous operation. olyaluminum chloride Flow meter (pulse/analog) Sodium hydroxide Sodium hypochlorite Alarm output When the pump is used in combination with a level meter and checker, an alarm is output during abnormal pressure buildup. Alarm Example: For a single stroke (ump A), controls such as three strokes (ump B) and 2 strokes (ump C) can be enabled. ulse input-based proportional control ulse frequency-division The pump performs a single injection operation for 'n' times of input pulse signals. Setting range: n = 1 to 999 Setting example: n = 3 ulse frequency-magnification T *1 For T, this is available only when using timer function. The pump performs the injection operation 'n' times for a single input pulse signal. Setting range: n = 1 to 999 Setting example: n = 3 *1 Signal Signal ump operation ump operation Analog input signal-based proportional control M Automatic operation The pump operates for a specified number of strokes in the range of 0 to 0 strokes per minute in accordance with the setting value (set point, proportional band), upon receiving an analog input signal (4 to 20mA). (1) Set point (S) setting S setting range: 0 to 100% Discharge volume Fixed B, variable S (2) roportional band (B) setting B setting range: -999 to 999% Fixed S, variable B

11 Input signal Output signal Control Item Digital Number of ports Analog Type Number of ports Digital Type Manual operation Number of strokes Discharge volume control ulse proportional control Analog proportional control Timer control External operation & stop input signal (pulse type) Stop signal, pulse signal Sync pulse, alarm output 0.1 to maximum discharge volume (Enables setting in 0.1mL/minute units) M (analog type) Stop signal, pulse signal Sync pulse, alarm output 1 to 0 (Enables setting in 1-stroke units) T (timer type) Stop signal, pulse signal Sync pulse, alarm output Timer control Interval mode ump operation can be turned on and off in accordance with the setting of the timer. You can set any ON and OFF period for one pattern each in the range of 1 to 9999 minutes. Setting example: ON period: 5 minutes OFF period: 3 minutes 5 minutes 5 minutes 5 minutes DAY mode T The pump operates automatically everyday using the same ON and OFF timing that is set. You can set up to nine program patterns within the range of 0:00 to 24:00 in 1-minute unit. DAY mode cannot be used together with the WEEK mode. Setting example: ON time: OFF time: 3 minutes 3 minutes 3 minutes When both interval mode and pulse operation are simultaneously set, the pump will operate in accordance with pulse frequency-division or pulse frequency-magnification setting within the ON time set for the DAY mode and interval mode. WEEK mode The pump automatically operates every week at the same ON and OFF time being set for the day of the week. You can set one program pattern for each day of the week. You can set the ON time from 0:00 to 24:00 and OFF time within the range 0:00 to 48:00 in 1-minute unit. WEEK mode cannot be used together with DAY mode. Setting example Mon Tue Wed Thu Fri Sat Sun Mon Tue ON time Mon Time that can be set OFF time for each program ON time ump operation time Tue OFF time ON time Wed OFF time ON time Thu OFF time ON time Fri OFF time ON time Sat OFF time ON time Sun OFF time When the pulse proportional control operation is set, the pump will operate in accordance with the pulse frequency-division or pulse frequency-magnification set for this operation. When both interval mode and pulse proportional control operation are simultaneously set, the pump will operate in accordance with pulse frequency-division or pulse frequency-magnification set for this operation.*1 *1 The number of strokes will be the value set in each program. The following combination of functions can also be used besides the abovementioned combination. Interval mode External operation control DAY mode External operation control DAY mode ulse proportional control Interval mode ulse proportional control External stop control WEEK mode External stop control WEEK mode

12 code Not all model combinations are possible. When selecting the pump model, first check Specification and Liguid-end material. VTCE 49 W S JL Series name (discharge volume standard) Liquid-end material Hose standard (size/material) Joint specification Applicable standard ower plug : Standard (pulse input) type M: Analog input type T: Timer control type [General chemical liquid injection model w/relief valve] R : ml/min 60R : 60mL/min 100R : 100mL/min [General chemical liquid injection model] : ml/min 60 : 60mL/min 100 :100mL/min 200 :220mL/min*1 [Boiler chemical liquid injection model w/relief valve*1] R : 28mL/min VTCE FTCE FTCF FTCT 6TCT VTCET E/FE/TFE 1/4" 3/8" E/FE 4 6 A W : Standard BW : Boiler S : Standard CE : CE marking -compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire [Boiler chemical liquid injection model*1] : 28mL/min [High-pressure chemical liquid injection model *1] : 25mL/min VTCET RC 1/4 FNT 1/4 : High-pressure [High-viscosity chemical liquid injection model] 60 : 60mL/min 100 : 100mL/min V : High-viscosity *1 SAFE mode cannot be used. Specifications Specification Max.discharge volume*1 Max.discharge pressure*1 Stroke speed Stroke length Connection (hose/tube:i.d x O.D) Viscosity of transfer liquid Temperature of transfer liquid Ambient temperature Environmental resistance Insulation class Weight kg ml/min L/h Ma bar Discharge side Suction side Air-release R/ R/ 60R/ VTCE/ FTCE/FTCF FTCT 6TCT VTCET(boiler) VTCET(high-pressure) VTCE/ FTCE/FTCF FTCT 6TCT (high-viscosity) /1.0 * /1.0 * /10 * /10 * strokes/min (Enables setting in 1-stroke units) mm (Enables adjustment using the dial) 6 x 11 6 x 8 6 x 8(FE) 4 x 6(A) Rc1/4 6 x 8 6 x 8(FE) 12 x 18 6 x 8(TFE) 6 x 8 6 x 8(TFE) 1/4"x3/8" 1/4"x3/8"(FE) 4 x 9 4 x 9 1/4"x3/8" 1/4"x3/8"(FE) 1/4" x 3/8" 4 x 6 (soft hose) - 4 x 6 (soft hose) - 50mas or less 3,000mas or less*3 0 40(no freezing allowed) 0 40 IEC standard:i65 or equivalent (water-&dust-proof) B x 9( braidedhose) 6 x 8 1/4"x3/8" *1 Conditions:Clean water, room temperature. *2 0.7Ma (7bar) for models w/relief valve(r type) whereas 1.0Ma (10bar) for models w/o relief valve. *3 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. Specification Max.discharge volume*1 Max.discharge pressure*1 Stroke speed Stroke length Connection (hose/tube:i.d x O.D) ml/min L/h Ma bar 100R/ VTCE/ FTCE/FTCF FTCT 6TCT (high-viscosity) VTCE/ strokes/min (Enables setting in 1-stroke units) mm (Enables adjustment using the dial) Discharge side 6 x 11 6 x 8 6 x 8(FE) 6 x 8 6 x 8(TFE) 1/4"x3/8" 1/4"x3/8"(FE) Suction side 1/4" x 3/8" 12 x 18 6 x 11 6 x 8 1/4" x 3/8" Air-release 4 x 6 (soft hose) - - Viscosity of transfer liquid 50mas or less 3,000mas or less*2 50mas or less Temperature of transfer liquid 0 40(no freezing allowed) Ambient temperature 0 40 Environmental resistance IEC standard:i65 or equivalent (water-&dust-proof) Insulation class B Weight kg *1 Conditions:Clean water, room temperature. *2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.

13 Control function specifications Item M T Number of ports Digital Analog Input signal Specifications Digital Open collector or non-voltage pulse Open collector or non-voltage pulse Open collector or non-voltage pulse Analog DC 4-20mA Type Stop signal ulse signal Stop signal Analog signal Stop signal ulse signal Number of ports Digital Output signal Specifications Type Open collector Sync pulse Alarm output Open collector Sync pulse Alarm output Open collector Sync pulse Alarm output Manual operation ulse proportional control Number of strokes Discharge volume control Division Magnification 0.1 to maximum discharge volume (Setting in 0.1mL/min. units enabled) 1/9991/ to 0 (Enables setting in 1-stroke units) Analog proportional control roportional band/set point method Interval 1 pattern19999 DAY 9pattern Control Timer WEEK 7pattern DAY + Interval WEEK + Interval Timer + ulse proportional control Division Magnification 1/9991/ External operation signal External stop signal Operation sync pulse Alarm output Accessories ower cable(2m) is attached. ower supply specifications Item General chemical model Boiler High pressure High viscosity VTCE FTCE FTCF FTCT 6TCT VTCET VTCET Item R/ R/ Boiler High pressure 60R/60 100R/ Hose Tube 3m 3m 3m 3m Discharge side: 2 Suction side: 1 Suction side: 1 3m Rated voltage Number of phases Frequency Maximum current V Hz A AC V±10 Single phase 50/60Hz Air purge hose with relief valve*1 1 * Maximum power consumption VA Anti siphonal check valve 1setR1/2) (R1/2 or R3/8) 1set R1/2) Average power consumption Cable W Cabtyre cable Foot valve 1set Ceramic weight 1set Hose pump 1set Cable ties (INSULOK ) for relief hose (spare)*3 1 1 Signal cable 2m ump attachment bolts and nuts 2 sets (M5x) Instruction manual 1copy *1 This hose is already attached to models with the simple relief valve. *2 This hose is not supplied with 200-type models. *3 This accessory is supplied with models with the simple relief valve. External dimensions The shape and dimensions differ slightly depending on the liguid-end material and connection type.

14 Middle Capacity ZD ZD No-input Zi Advanced Functions Zi4 Zi8 Digital-input & Common Functions Direct Entry of Injection Amount The injection amount can be set according to three patterns: [By stroke speed] Setting range: 1 to 0 strokes/min (minimum setting increment: 1 stroke/min) [By discharge volume] Setting range: 0.1 to (maximum discharge volume of selected model) ml/min (minimum setting increment: 0.1 ml/min) [By percentage] Setting range: 1 to 100% (minimum setting increment: 1% (3 strokes/min)) Extensive Range of Liquid-end Materials Wide Voltage Range ower Supply AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V ( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. High-viscosity The ZD series can also be used for the injection of polymer coagulant. When transferring high-viscosity liquids, the maximum discharge volume may be lower * than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. VTCE/ Material: Application example: Transfer/ inject ion of general chemicals 6TCT Material: Stainless steel (SUS316. 4) Application example: Transfer/ inject ion of solutions/special chemicals FTCT Material: VDF Application example: Transfer/ inject ion of special chemicals (e.g. strong and mixed acids) (high-viscosity type*) Material: Application example: Transfer/injection of high-viscosity liquids rovided for ZD series only. * ZD 20 0 Simple Key Layout STROKE LENGTH Stroke-length adjustment dial % ilot lamp LCD panel START/STO key MODE key U key DOWN key 3-directional ump Head Separate-type Head & Controller Zi STROKE LENGTH Stroke-length adjustment dial % * ilot lamp LCD panel w/ backlight* START/STO key MODE key U key DOWN key Backlight is provided only on Zi8. This feature is limited depending on the operating conditions. Consult us for details. Water- & Dust-proof Specifications IEC standard: I65 or equivalent Avoid condensation and immersion in water. Outdoor Use

15 ZD Quick & Easy Calibration The ZD Series is provided with easy calibration function for accurate pump calibration. Just push the button to automatically discharge 0 strokes' worth of chemical and enter the actual discharge volume that you will be measuring. This is all you need to do for accurate calibration. Zi4 Zi8 External operation & stop control The pump can be turned on and off using a input signal from an external device. Level meter Zi4 Zi8 Analog-Input roportional Control The injection amount (stroke frequency: 0 to 0 strokes/min) can be set according to the analog input signal (Zi4: 4 to 20 ma, Z i8: 0 to 20 ma or 4 to 20 ma) from an ex ter nal device. Conventional system ph meter ph C ph Control Controller INV. Zi ph meter ph C Controller Zi4 Zi8 Zi4 Zi8 Chemical liquid tank ulse-input roportional Control & External Stop Input Control ump ON/OFF can be controlled by an external stop input signal. Also, the injection amount (1/9999 to 9999 strokes/pulse) can be set according to the pulse input signal from an external device. Main piping ulse-transmitting flow meter Level Switch Zi/ZD Zi Residual Chlorine Control Zi4 Zi8 For details on the Level Switch, see "Option" on the back cover. Conventional system INV. Zi Zi8 Controller C R Residual chlorine meter Zi C Controller R Residual chlorine meter 2-point Level Switch Control Control such as alarm display and output, and pump stop is performed in accordance with the remaining amount of chemicals. 2-point Level Switch Motor Driven ump. Inverter required Zi. Inverter not required Zi8 Count (batch) & Interval (timer) Operation. Narrow control range of 1:10 (6 to 60 Hz). Wide control range of 1:0 (1 to 0 strokes/min) Count setting 1 to 9999 strokes (x1, x10, x100, x1000) Start/Stop signal Interval setting. Raw liquid must be diluted since the discharge volume per stroke is large.. Raw liquid can be injected since the discharge volume per stroke is small. ON time : 1 to 9999 min OFF time : 1 to 9999 min Zi8

16 Specification: ZD Specification Max. discharge volume* Max. discharge pressure* Stroke speed Stroke length ml/min L/h Ma bar Discharge side Connection (hose/tube: I.D x O.D) Suction side Air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Operation mode ower supply Weight Manual Rated voltage No. of phases/frequency Maximum current ower consumption VTCE FTCT STCT VTCE FTCT STCT x 18 9 x 12 3/8" x 1/2" x 15 (TFE) to 0 strokes/min (digital setting) 0.2 to 1.5 mm (manual dial) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to x 18 9 x 12 3/8" x 1/2" 35 to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m Less than 85 db (no freezing allowed) x 15 (TFE) Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Specification: Zi4/Zi8 AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 3.0 A Max.: 500 VA/Ave.: W 4.0 kg 4.2 kg 6.0 kg 4.0 kg 4.2 kg 6.0 kg Conditions: Clean water, room temperature * Specification Max. discharge volume* 1 Max. discharge pressure* 1 Stroke speed Stroke length Connection (hose/tube: I.D x O.D) Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input Signal Operation mode Discharge side Suction side Air-release ml/min L/h Ma bar ower supply to Flow Checker* 4 ower supply Weight Digital* 3 Input Output Manual Analog-Input proportional control* 5 ulse-input proportional control* 5 Count operation (batch control) Auto Interval operation (timer control) External stop input control 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption VTCE FTCT STCT VTCE FTCT STCT x 18 9 x 12 3/8" x 1/2" to 0 strokes/min (digital setting) 0.2 to 1.5 mm (adjustable by manual dial) 12 x 15 (TFE) 4 x 6 (soft hose) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m Less than 85 db Zi4 : 1 port : Analog signal (4 to 20 ma DC, input resistance: approx.110 )* 2 Zi8 : 1 port : Analog signal (4 to 20 ma DC, 0 to 20 ma, input resistance: approx. 110 )* 2 Zi4 : 1 port : High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 2 1 port : ump stop signal (no-voltage contact or open collector, input resistance: approx. 2 k, min. pulse width: 50 msec (ON time)) Zi8 : 2 ports: High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 2 2 ports: Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Reset/Restart signal, Alarm reset signal, Flow Checker signal (only when Flow Checker is used), (4 selectable) Level Switch signal (only when Level Switch is used) Zi8 only : 2 ports: ulse signal (3 ma DC, 25 V or less) Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Operation end signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), (2 selectable) ulse-input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used) Zi8 only Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Control possible by roportional Band (B/variable range: 1 to 999%) setting/shift (S/variable range: 0 to 100%) setting Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting Zi8 only : 1 to 9999 strokes (x1, x10, x100, x1000) Zi8 only : ON time: 1 to 9999 min/off time: 1 to 9999 min "ST" flashing display, pump stopped x 18 9 x 12 3/8" x 1/2" Zi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 3.0 A Max.: 500 VA/Ave.: W 4.0 kg 4.2 kg 6.0 kg 4.0 kg 4.2 kg 6.0 kg * 1 Conditions: Clean water, room temperature * 2 Combined use of analog input signal and high-speed * pulse signal not possible. * 3 For a detailed explanation on signals, see "Digital Signal" on page 26. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 14. * x 15 (TFE) 4 For details on the Flow Checker, see "Option" on the back cover. 6 When 2-point Level Switch is used

17 Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". ZD R VTCE 4x9 W S JL (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug [for injection of general chemicals] 0 : 0 ml/min 500 : 500 ml/min VTCE FTCT STCT 12 x 18 9 x 12 E 3/8" x 1/2" E 12 x 15 TFE W : Standard S : Standard CE : CE marking-compatible Zi8 R VTCE 4x9 W S JL Series name 2 (discharge volume standard) 3 Liquid-end material 4 Hose standard (size/material) 5 Joint specification 6 Applicable standard [for injection of general chemicals] Zi4 : Analog/ Digital-Input Zi8 : Analog/ Digital-Input & Digital-Output 0 : 0 ml/min 500 : 500 ml/min VTCE FTCT STCT 12 x 18 9 x 12 E 3/8" x 1/2" E 12 x 15 TFE W : Standard S : Standard CE : CE marking-compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire NON : No Cable 7 ower plug EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire NON : No Cable Accessory When "NON" is selected for power plug, the power cable(2m) is not provided. ZD Zi4/Zi8 Item VTCE FTCT STCT VTCE FTCT STCT Hose/ Tube* 1 Anti-siphon check valve Foot valve Ceramic weight ump mounting nuts/ bolts Operation manual (R1/2 or R3/8) * 2 3 m (R1/2) 2 sets (M5 x ) (R1/2 or R3/8) * 2 * 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. 2 Only when E tube is selected * 3 m (R1/2) Zi/ZD art Liquid-end Material Also refer to the "Corrosion-resistance Table" on page 26. VTCE FTCT STCT (L-size) ump head Diaphragm Check ball TFE Ceramic VDF SUS4 O-ring EDM Fluoro-rubber TFE Valve seat Joint Ball stopper EDM Special fluoro-rubber TFE VDF TFE (valve stopper) SUS4 External Dimension (mm) VTCE/ FTCT/STCT High-viscosity VTCE/ FTCT/STCT The shape and dimensions differ slightly depending on the liquid-end material and connection type. The mounting pitch allows mounting from 87 to 110 mm.

18 ON Large Capacity Advanced Functions Large-capacity Lineup of four models supporting large-capacity injection up to 1000 ml/min Max ml/min High-viscosity The series can also be used for the injection of polymer coagulant. Max. 00ma.s* When transferring high-viscosity liquids, the maximum discharge volume may be lower * than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. Direct Entry of Injection Amount The injection amount can be set according to three patterns: [By stroke speed] Setting range: 1 to 0 strokes/min (minimum setting increment: 1 stroke/min) [By discharge volume] Setting range: 0.1 to (maximum discharge volume of selected model) ml/min (minimum setting increment: 0.1 ml/min) [By percentage] Setting range: 1 to 100% (minimum setting increment: 1% (3 strokes/min)) Wide Voltage Range ower Supply AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. Simple key Layout Stroke-length adjustment dial Water- & Dust-proof Specifications IEC standard: I65 or equivalent Avoid condensation and immersion in water. Outdoor Use ilot lamp Automatic operation lamp Alarm lamp MODE key START/STO key AUTO ALARM 0 START STROKE LENGTH 100% FUNC SET RESET Large 2-row LCD display w/ backlight Function key SET/RESET key Quick & Easy Calibration The Series is provided with easy calibration function for accurate pump calibration. Just push the button to automatically discharge 0 strokes' worth of chemical and enter the actual discharge volume that you will be measuring. This is all you need to do for accurate calibration. STROKE LENGTH 100% Extensive Range of Liquid-end Materials VTCE/ Material: Application example: Transfer/injection of general chemicals (high-viscosity type) Material: Application example: Transfer/injection of high-viscosity liquids For details, refer to the "Liquid-end Material" table on the following page. FTCT Material: VDF Application example: Transfer/injection of special chemicals (e.g. strong and mixed acids)

19 Analog-Input roportional Control 2-point Level Switch Control The injection amount (stroke frequency: 0 to 0 strokes/min) can be set according to the analog input signal (0 to 20 ma or 4 to 20 ma) from an ex ter nal device. Conventional system ph Control Control such as alarm display and output, and pump stop is performed in accordance with the remaining amount of chemicals. 2-point Level Switch ph meter ph C Controller ph meter ph C Controller INV. Count (batch) & Interval (timer) Operation Residual Chlorine Control Count setting 1 to 9999 strokes (x1, x10, x100, x1000) Start/Stop signal Conventional system Interval setting INV. ON time : 1 to 9999 min OFF time : 1 to 9999 min Controller C Controller C Motor Driven ump. Inverter required R Residual chlorine meter. Inverter not required R Residual chlorine meter Example of Safe Hose iping for Fully Demonstrating the erformance of the. Narrow control range of 1:10 (6 to 60 Hz). Wide control range of 1:0 (1 to 0 strokes/min). Raw liquid must be diluted since the discharge volume per stroke is large.. Raw liquid can be injected since the discharge volume per stroke is small. 2 Damper Anti-siphonal check valve ressure gage 3-way joint ulse-input roportional Control & External Stop Input Control 1 Relief valve Return piping ump ON/OFF can be controlled by an external stop input signal. Also, the injection amount (1/9999 to 9999 strokes/pulse) can be set according to the pulse input signal from an external device. Main piping ulse-transmitting flow meter Level Switch Suction valve (w/ built-in strainer) 1 Relief valve This valve automatically relieves excess pressure that occurs in the discharge side piping due to blockage by foreign objects and tightening of the valve to prevent accidents or possible damage to the pump and piping. 2 Damper Install a damper or air chamber when the piping is long or to suppress vibration on the piping. For details on the Level Switch, see "Option" on the back cover.

20 Specification Specification Max. discharge volume* 1 Max. discharge pressure* 1 Stroke speed Stroke length ml/min L/h Ma bar VTCE FTCT high-viscosity VTCE FTCT high-viscosity ( type ) ( type ) to 0 strokes/min (digital setting) 0.3 to 1.5 mm (adjustable by manual dial) Connection (hose/tube: I.D x O.D) Discharge side Suction side 12 x 18 FNT 1/2 12 x 15 (TFE) FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) 12 x 18 FNT 1/2 12 x 15 (TFE) FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input Signal Operation mode ower supply Weight Relief /air-release Digital* 4 Input Output Manual Analog-Input proportional control* 5 ulse-input proportional control* 5 Count operation (batch control) Auto Interval operation (timer control) External stop input control 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption * 1 Conditions: Clean water, room temperature * 50 ma. s 00 ma. s* 2 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m Less than 85 db 1 port : Analog signal (4 to 20 ma DC, 0 to 20 ma, input resistance: approx. 110 )* 3 2 ports: High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 3 2 ports: Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal, (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal 2 ports: ulse signal (10 ma DC, 25 V or less) Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal, (4 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), ulse-input error signal, Analog-Input error signal Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Control possible by roportional Band (B) setting/set oint (S) setting Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting 1 to 9999 strokes (x1, x10, x100, x1000) ON time: 1 to 9999 min/off time: 1 to 9999 min "ST" flashing display, pump stopped [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 4.0 A Max.: 750 VA/Ave.: 100 W 11 kg 00 ma. s* 2 2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. 4 For a detailed explanation on signals, see "Digital Signal" on page When 2-point Level Switch is used * 3 Combined * use of Analog-Input signal and high-speed pulse signal not possible. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 18. * Code (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug 7 General [for injection of general chemicals] specification 0 : 0 ml/min 500 : 500 ml/min 700 : 700 ml/min 1000 : 1000 ml/min [High-viscosity type] 0 : 0 ml/min 500 : 500 ml/min 700 : 700 ml/min 1000 : 1000 ml/min Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". 0 VTCE 12 x18 W S JL VTCE FTCT 12 x x 15 TFE FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) W : Standard V : high-viscosity type S : Standard CE : CE marking-compatible EU : Euro plug* UL : UL plug AU : Australia plug UK : UK plug* JL : Japan lead wire None : Standard X : Special Item Accessory Hose/ Tube* Anti-siphon check valve Strainer ump mounting nuts/ bolts(m5 x ) Operation manual VTCE The 4-pin/8-pin cable (2 m or 5 m selectable) is an option. FTCT (High-viscosity type) 3 m (R1/2 or R3/8) 4 sets For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. *

21 Specification Specification ml/min Max. discharge volume* 1 L/h Ma Max. discharge pressure* 1 bar Stroke speed Stroke length Discharge side Connection (hose/tube: Suction side I.D x O.D) Relief /air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input Signal Operation mode ower supply Weight Digital* 4 Input VTCE 12 x 18 FNT 1/2 50ma. s FTCT 12 x 15 (TFE) FNT 1/2 high-viscosity ( type ) FNT 3/4 MNT 3/4 V 20 (Union Joint) 00ma. s* 2 Less than 85 db 1 port : Analog signal (4 to 20 ma DC, 0 to 20 ma, input resistance: approx. 110 )* 3 12 x 18 FNT 1/2 12 x 15 (TFE) FNT 1/2 2 ports: High-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 3 2 ports: Low-speed pulse signal (no-voltage contact or open collector, input resistance: approx. 2 k, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal, (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal 2 ports: ulse signal (10 ma DC, 25 V or less) Output Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal, (2 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), ulse-input error signal, Analog-Input error signal Manual Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Analog-Input Control possible by roportional Band (B) setting/set oint (S) proportional setting control* 5 ulse-input proportional Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting control* 5 Count operation 1 to 9999 strokes (x1, x10, x100, x1000) (batch control) Auto Interval operation (timer control) ON time: 1 to 9999 min/off time: 1 to 9999 min External stop input control "ST" flashing display, pump stopped 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption * 1 Conditions: Clean water, room temperature * art ump head Diaphragm Check ball O-rings Valve seat Joint Ball stopper Ball guide Compressed coil spring 1000 VTCE FTCT [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped VTCE FTCT EDM EDM Fluoro-rubber Special fluoro-rubber 1 to 0 strokes/min (digital setting) 0.3 to 1.5 mm (adjustable by manual dial) Ambient temperature: 0 to 40 / Transferring liquid: 0 to to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 4.0 A Max.: 750 VA/Ave.: 100 W 11 kg TFE Ceramic VDF TFE TFE VDF TFE(valve stopper) 50 ma. s (no freezing allowed) high-viscosity ( type ) FNT 3/4 MNT 3/4 V 20 (Union Joint) (high-viscosity type) Fluoro-rubber Special fluoro-rubber SUS4 00 ma. s* 2 2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. 4 For a detailed explanation on signals, see "Digital Signals" on page When 2-point Level Switch is used Liquid-end Material * 3 Combined * use of Analog-Input signal and high-speed pulse signal not possible. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 18. * Also refer to the "Corrosion-resistance Table" on page 26. External Dimension (mm) VTCE/ FTCT () C B A A D E D C B A E F B A A B C D E A B C D E F 0/ /500/ /500/ A B

22 For Sodium Hypochlorite DCL DCL DCLM DCLT Digital-input/output Timer Control CL CL CLM CLT Digital-input/output Timer Control CLZ CLZ No-input Two mechanisms for preventing gas lock In-line type automatic air-release mechanism DCL and CL are equipped with an air-release mechanism designed using a new concept. The in-line air-release mechanism of these models assures the elimination of air that is trapped in the pump head and automatically prevents the discharge trouble caused by gas lock. Conventional design Air New design Chemical liquid and air Chemical liquid Air block mechanism Air Liquid Air is discharged from a dedicated air purge port. Chemical liquid leaks into the air purge port side under some conditions and the discharge volume becomes unstable. Standby state The pressure inside the discharge side and pump head becomes equal and the air is compressed. Air-release performance Discharge process The smaller volume of air after it is compressed is discharged together with the liquid. Comparison of the time required to purge air that is trapped in the pump head between CL and previous models (CLZD, ARZD). Test conditions (Discharge pressure: 1.0Ma, air volume: 0.1mL) Test conditions (Discharge pressure: 1.0Ma, air volume: 0.5mL) Suction Air purge time [sec.] revious model CL type revious model AR type Approx. 60% reduction CL Air purge time [sec.] Unable to purge air revious model CL type revious model AR type Approx. 60% reduction CL Easy-to-check trapped air The transparent acrylic pump head, which has an innovative design to minimize dead space, enables the operator to check the trapped air at a glance. Anti siphonal check valve that prevents clogging at the injection point Injection point (no injection state) Conventional pumps DCL/CL series Main pipe (raw water) Crystallization caused by reaction between sodium hypochlorite and calcium in raw water. Main pipe (raw water) The check valve cap closes to prevent crystallization caused by reaction between sodium hypochlorite and calcium in raw water.

23 code Not all model combinations are possible. When selecting the pump model, first check Specification and Liguid-end material. DCL ATCF 4 9 W S JL Series name Control type (discharge volume standard) Liquid-end material Hose standard (size/material) Joint specification Applicable standard ower plug DCL : Air block and in-line type automatic airrelease functions CL : In-line type automatic air-release function None : Standard (pulse input) type M : Analog input type T : Timer control type W/ relief valve R: ml/min 60R: 60mL/min 100R: 90mL/min W/O relief valve : ml/min 60 : 60mL/min 100 : 90mL/min ATCF E 1/4" 3/8"E W: Standard S: Standard CE: CE marking -compatible EU:Euro plug UL :UL plug AU:Australia plug UK:UK plug JL:Japan lead wire CLZ None : No-input W/ relief valve R: ml/min W/O relief valve : 50mL/min ATCF E 1/4" 3/8"E W: Standard S: Standard CE: CE marking -compatible EU:Euro plug UL :UL plug AU:Australia plug UK:UK plug JL:Japan lead wire Specifications Specification Max.discharge volume Max.discharge pressure Stroke speed Stroke length Connection (hose/tube:i.d O.D) ml/min L/H Ma bar Discharge side Suction side Air-release - Degassing joint*3 1/4" 3/8" (soft hose) Viscosity of transfer liquid Temperature of transfer liquid Ambient temperature Environmental resistance Weight kg *1 Conditions:Clean water, room temperature. *2 0.7Ma (7bar) for models w/relief valve(r type) whereas 1.0Ma (10bar) for models w/o relief valve. *3 rovided for the DCL series only. DCL CL CLZ R 60R 100R R 60R 100R R 60R 100R to 0 strokes/min (Enables setting in 1-stroke units) 15 to 0 strokes/min (dial setting) 0.51 mm (Enables adjustment using the dial) Fixed at 1.0 mm /4" 3/8" /4" 3/8" /4" 3/8" /4" 3/8" /4" 3/8" /4" 3/8" 4 6 (soft hose) 4 6 (soft hose) /4" 3/8" /4" 3/8" /4" 3/8" /4" 3/8" /4" 3/8" (soft hose) mas or less 040(no freezing allowed) /4" 3/8" Liquid-end materials Accessories ower cable(2m)is attached. Item DCL CL CLZ Item DCL CL CLZ External dimensions DCL/DCLM/DCLT CL/CLM/CLT CLZ ump head Diaphragm Check ball O-ring Valve seat acking Joint Degassing joint Ball stopper AcrylicMMA TFE Ceramic Fluoro rubber Special fluoro rubber TFE Hose/tube Air purge hose with relief valve*1 Degassing joint Anti siphonal check valve Foot valve Cable ties (INSULOK ) for relief hose (spare)*2 Signal cable ump attachment bolts and nuts (hose already attached) 2m 3m 1m (R1/2) 1piece Operating instructions 1 copy *1 The air purge hose with relief valve is already attached to this pump. *2 This accessory is supplied for models with the relief valve (R type). (120) DCL/CL/CLZ Air purge port Air purge port 76 Air purge port 1 (206) 152 R (150.5) 87

24 For Sodium Hypochlorite AR Automatic Air-release ARZ No-input Automatic Relase of Air in ump Head Dead space inside the pump head has been limited to the bare minimum to prevent air entry and build up. Should air get into the pump, it is automatically released. Main piping Injection point Air-release piping At-a-glance Inspection of Air Entry The transparent acrylic pump head allows you to check at-a-glance if air has entered. Discharge piping Discharge Hose joint Air release Suction ARZ Air-release joint ump head Hose joint Suction piping Suction Bubbles or gas that occur in the chemical tank are sucked into the pump head. Air release The bubbles or gas pass through the Air-release joint and are fed back to the chemical tank along the Air-release piping. Discharge After all the bubbles or gas are discharged from the pump head, the chemical is discharged from the discharge side. revention of Clogging at Injection oint When injecting sodium hypochlorite, it reacts with calcium in the raw water that flows through the main piping and forms crystals at the injection point. The "Anti-siphon check valve with a duck-bill cap" was developed to solve this problem. This check valve solves all of your worries when injecting sodium hypochlorite, including overfeed and siphoning. Injection oint (when liquid is not being injected) Conventional check valve Main piping (raw water) Crystals form due to reaction with calcium in raw water. Main piping (raw water) AR The cap closes to prevent reaction with raw water and crystallization.

25 Specification Specification Max. discharge volume* Max. discharge pressure* Stroke speed Stroke length ml/min L/h Ma bar Discharge side Connection (hose/tube: Suction side I.D x O.D) Air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Rated voltage ower No. of phases/frequency supply Maximum current Weight ower consumption Max. Ave The operation modes of the ARZ is the same as those for the Z, respectively x 9 6 x 8 1/4" x 3/8" 2.0 A 200 VA 15 W 1.7 kg ARZ to 0 strokes/min (dial setting) Fixed at 1.0 mm 6 x 11 6 x 8 1/4" x 3/8" 4 x 8 (soft hose) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (water- and dust-proof) Less than 1,000 m Less than 85 db AC 100 to 240 V ( 10%) 1-phase/50 or 60 Hz 2.5 A 250 VA 18 W 1.8 kg Conditions: Clean water, room temperature * Liquid End Material All s art ump head Acrylic (MMA) Diaphragm TFE Check ball Ceramic O-ring Fluoro-rubber Valve seat Special fluoro-rubber Joint Ball stopper Compressed coil spring Hastelloy C Also refer to the "Corrosion-resistance Table" on page 26. * Item Accessory Hose/ Tube* 1 Air-release hose* 1 Anti-siphon check valve Foot valve Ceramic weight ump mounting nuts/ bolts Operation manual All s 3 m 1 m (R1/2) * 2 2 sets (M5 x ) ower cable(2m)is attached * 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. 2 Only when E tube is selected * Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". ARZ 31 CL 4x9 W S JL Series name 2 (discharge volume standard) 3 Liquid-end material 4 Hose standard (size/material) 5 Joint specification 7 ower plug ARZ : Manual setting, No-Input 31 : ml/min CL 4 x 9 61 : 60 ml/min 6 x : 100 ml/min 6 x 8 E 1/4" x 3/8" E W : Standard 6 Applicable standard S : Standard CE : CE marking-compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire External Dimension (mm) ARZ 83 1 R AR (202) 87 (57) (190) 118 The mounting pitch allows mounting from 87 to 110 mm.

26 Application examples Simple water purifying treatment Elevated water tank Residual chlorine meter Control panel DC420mA Distributing reservoir Distribution Control panel Residual chlorine indicator Residual chlorine meter Residual chlorine indicator Residual chlorine indicator ower supply Sampling valve Feedwater Residual chlorine meter Level switch Water lifting pump Circulation pump Elevated water tank Chemical injection system TS Sampling valve Liquid Water-storage tank transfer pump Circulation pump Sodium hypochlorite storage tank Water receiving tank Circulation type bathtub Swimming pool Bathtub Residual chlorine meter ower supply DC420mA FR recorder ower supply Swimming pool C-type holder Residual chlorine meter DC420mA FR recorder ower supply Filter or cartridge strainer ressure reducing valve Level switch Filter or cartridge strainer Sampling valve Sampling valve Hair catcher Circulation pump Filter Heat exchanger Sodium hypochlorite storage tank Balancing tank Hair catcher Circulation pump Filter Heat exchanger Chemical injection system TS Chemical injection for boiler Water treatment of cooling tower Building Cooling tower Boiler Chemical injection system TS Circulation pump Waste water Circulation pump Heat exchanger Neutralization of ph in waste water Dechlorination treatment of RO film process rimary treatment Dechlorination treatment Control panel Chemical injection system TS ph recorder ph meter Sodium hypochlorite storage tank Control panel Dechlorination solvent tank Control panel Residual chlorine meter Raw water Mixer Discharge Industrial water Filter Filter Static mixer Waterstorage tank Static mixer Neutralization tank Tank with ph recording instrument High-pressure pump Residual chlorine meter

27 Explanation Digital Signal Also refer to "Specification" for each model. Input Output Unassigned ulse signal Stop signal Start signal Reset/Restart signal Alarm reset signal Level Switch signal* 1 Compulsive MAX operation signal Unassigned Solenoid-operation sync pulse signal In-operation signal Running signal Operation end signal Lamp a Alarm signal Tank-level alarm signal* 1 ulse-input error signal Analog-Input error signal Selected ports not to be unassigned Input signal required for ulse-input proportional control Signal from an external device to stop the pump Signal from an external device to start the pump Signal from an external device to reset the current value (count, time) during count operation (batch control) or interval operation (timer control) and to restart operation Signal from an external device to reset display/output of errors and alarms Signal from the Level Switch installed in the tank to stop the pump operation When 2-point Level Switch is used... [Low tank-level alarm] "E-02" displayed and alarm output/ [Lower tank-level alarm] "ST" flashing display and pump stopped Signal that forces the pump to run at MAX speed (0 strokes/min) regardless of operation mode Selected ports not to be unassigned One pulse signal to be output per stroke Signal to be output during the operation (including "in standby") Signal to be output during the pump is running (not including "in standby") Signal to be output when the preset number of strokes is reached during count operation (batch control) Signal to be output when one of the following errors and alarms is detected Signal to be output when 2-point Level Switch is used and the volume of the chemical has fallen to the preset (low) level (Low tank-level alarm) For Lower tank-level alarm, "ST" flashing display and pump stopped. However, no signal is output Signal to be output when the number of ulse-input signals momentarily exceeds the buffer size during ulse-input proportional control Signal to be output when the Analog-Input signal goes outside of the specified range during Analog -Input proportional control (In the case of the 4 to 20 ma range, 3 ma or less or 22 ma or more. In the case of the 0 to 20 ma range, 0 ma or less or 22 ma or more) 1 When Level Switch is used * Error & Alarm Also refer to "By Function" on page 4. Error/ Alarm Memory-read error Tank-level alarm* 1 ulse-input error Analog-Input error ump circuit- or program-related error Alarm when the chemical volume has fallen to the preset (low) level Error when the number of ulse-input signals momentarily exceeds the buffer size during ulse-input proportional control Error when the Analog-Input signal goes outside of the specified range during Analog -Input proportional control (In the case of the 4 to 20 ma range, 3 ma or less or 22 ma or more. In the case of the 0 to 20 ma range, 0 ma or less or 22 ma or more) 1 When Flow Checker is used * Corrosion-resistance Table Also refer to "Liquid-end Material" for each model. VTCET Liquid-end material for injection of high-viscosity VTCE FTCE FTCF FTCT ( boiler chemicals) ( type ) 6TCT STCT ATCF Chemical (0 to 40 ) Z/ only * * /ZD/ only Hydrochloric acid HC to 20% to 20% to 38% Sulfuric acid H2SO4 to 60% to 80% to 60% to 80% to 98% 98% Sodium hydroxide NaOH Aqueous ammonia NH4OH Sodium hypochlorite NaC O to 12% to 12% to 12% Hydrogen peroxide H2O2 to % to % to 90% oly-aluminum chloride (AC) Aluminum sulfate A 2 (SO4)3 olymer coagulants to 00ma. s* When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. * The corrosion resistance of materials is greatly affected by temperature, concentration, UV rays, and other environmental conditions. For this reason, this selection table does not completely guarantee safety. The above figures are the corrosion resistance for pump liquid-end materials. Consult TACMINA separately regarding the corrosion resistance of hoses and tubes. OTHER

28 Options Degassing joint Degassing joint is installed at the suction side of a pump. It separates absorbed air bubbles from the liquid to prevent air bubbles from entering the pump head. This joint is supplied with the DCL series as standard equipment. Flow checker Flow checker is highly resistant to acid and alkalis and allows the injection operation of the pump to be checked at low cost. The pump-direct connection type and hose connection type are the two types of volume checkers available. arts kit arts kit includes all required consumables in a set and is more economical than purchasing the parts separately. Since all consumables are packaged in one box, it also makes inventory management easier. Residual pressure exhaustion valve Residual pressure exhaustion valve is directly connected to the discharge side of the pump so that the pipes can be safely purged of abnormal pressure that builds up. It also enables residual pressure and residual liquid to be safely discharged when maintenance services are performed. ulse generator type flowmeter When using this flowmeter in combination with a Tacmina pulse signal input type metering pump, you can construct a simple and low-cost injection system proportional to the required flow rate. Related equipments ump and tank combination Chemical injection system TS Tank capacity /50/120 L Compact design and easy to assemble in equipment and install. You can start operation by simply connecting the power supply and piping. Relief valve (safety valve) Tank capacity 25 to 1000L Relief valve automatically releases excessive pressure that builds up inside the discharge side pipes due to clogging of the pipes or while the discharge valve is closed. It can prevent accidents such as damage to the pump or piping. Flow indicator and photoelectric sensor Tank These optional products enable you to check the injection operation visually as well as by means of a sensor. Back pressure valve Float switch Back pressure valve prevents excessive liquid flow and siphon effect by sealing the outlet port of the liquid with a diaphragm, and by applying just enough force (back pressure) to overcome the fluid inertia force. Float switch will stop the pump when the remaining volume of chemical liquid in the tank becomes low. They also cause an alarm to be emitted to notify you that it is time to refill the liquid. Two types of float switches are available, namely the float type with choices of one-point and two-point type sensors, and the electrode type, which is highly resistant to chemicals. Solution tank E tank tank roduct designs and specifications are subject to change without notice for product improvement. Head Office: Awajimachi, Chuo-ku, Osaka Japan Tel.+81(0) Fax.+81(0) URL trade@tacmina.com EC-054 (2) /4/JSS

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Diaphragm Metering ump www.tacmina.com Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Diaphragm Metering ump www.tacmina.com Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Metering Pump Features Equipped with New Functions for Higher Safety, Superior Eco-friendly Performance, and Optimal Ease of Use Higher Safety Three types of safety functions that realize

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Metering Pump Features Equipped with New Functions for Higher Safety, Superior Eco-friendly Performance, and Optimal Ease of Use Higher Safety Three types of safety functions that realize

More information

Series PZ Pulse Metering Pumps

Series PZ Pulse Metering Pumps BULLETIN PZ- 22 Series PZ Pulse Metering Pumps Manual or programmable A single model accepts either pulse or milliamp signals Operates on any single-phase voltage from 94 vac through 264 vac Pump delivery

More information

PDF-A Electromagnetic metering pumps. EHN series

PDF-A Electromagnetic metering pumps. EHN series PDF-A 0045-03 Electromagnetic metering pumps EHN series The latest electromagnetic metering pump equipped with digital controller & multi-voltage EHN Series is the latest electromagnet drive & diaphragm

More information

Series PZ / PZi / PZiG

Series PZ / PZi / PZiG BULLETIN PZ- 8 Series PZ / PZi / Pulse Metering Pumps US Patent #6,283,717 The Power of Intelligent Pumps Expands! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 (programmable) Features MANUAL EXTERNAL

More information

Excel AD Electromagnetic dosing pump

Excel AD Electromagnetic dosing pump Flow rate Up to 7.6 l/h Pressure Up to 17.3 bar Liquid ends Acrylic, stainless steel, PP, PVC, PVDF, designed for viscous products, designed for degassing products LCD user interface with display of the

More information

Series PZ and PZi Pulse Metering Pumps

Series PZ and PZi Pulse Metering Pumps BULLETIN PZ-3 Series PZ and PZi Pulse Metering Pumps CHEMICAL PUMP CO., INC. US Patent #6,283,717 The Age of Intelligent Pumps Finally Arrives! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 Intelligent

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

APL Direct-driven type

APL Direct-driven type Pump APL Direct-driven type Metered transfer Solving Trouble and Dissatisfaction of Transfer Pumps in a Single Stroke With rotary volumetric pumps and other conventional pumps, there has always been the

More information

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps Overview: Sigma/ 1 (S1Cb) The Sigma/1 motor diaphragm are produced with a high-strength inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion. The

More information

Diaphragm-Type Process Metering Pump

Diaphragm-Type Process Metering Pump Diaphragm-Type Process Metering Pump Z TACMINA Core Technology TACMINA is a specialist manufacturer of chemical pumps that incorporate "diaphragms" as their core technology. For about 50 years now, we

More information

FLEX-PRO TM PERISTALTIC PUMPS

FLEX-PRO TM PERISTALTIC PUMPS FLEX-PRO TM PERISTALTIC PUMPS Applications Chemical Wastewater treatment Chlorination Pulp & Paper Slurries Printing inks Oil based fluids Gaseous fluids Shear sensitive fluids Caustics Chemical Slurries

More information

PKX MA/A. Characteristics

PKX MA/A. Characteristics PKX MA/A The PKX is a PTFE diaphragm type Solenoid Metering Pump that distinguishes itself for its simplicity of use. It has proven reliability and quality and due to it compact design and versatility

More information

Solenoid-driven Diaphragm Metering Pump. SP/SA/ST Series

Solenoid-driven Diaphragm Metering Pump. SP/SA/ST Series Solenoid-driven Diaphragm Metering Pump SP/SA/ST Series INSTALLATION, OPERATION AND MAINTENANCE MANUAL Before beginning operation, read this manual carefully! Ignoring the instructions in this IOM MANUAL

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps Overview: Sigma/ 3 (S3Cb) The Sigma/3 motor diaphragm are produced with a high-strength metal inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion.

More information

Solenoid-driven Diaphragm Metering Pump. PZ Series OPERATION MANUAL

Solenoid-driven Diaphragm Metering Pump. PZ Series OPERATION MANUAL Solenoid-driven Diaphragm Metering Pump PZ Series OPERATION MANUAL Please read this OPERATION MANUAL carefully before use. Operating the pump incorrectly in disregard of these instructions may lead to

More information

DLX MA/MB. Characteristics

DLX MA/MB. Characteristics DLX MA/MB The DLX range of pumps is a proven PTFE diaphragm type Solenoid Metering Pump that distinguishes itself with having a wide range of control options. Since its launch the DLX pump range has given

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

DLX MA/AD. Characteristics

DLX MA/AD. Characteristics DLX MA/AD The DLX range of pumps is a proven PTFE diaphragm type Solenoid Metering Pump that distinguishes itself with having a wide range of control options. Since its launch the DLX pump range has given

More information

Diaphragm Metering Pumps

Diaphragm Metering Pumps DATA BOOK DME/DMS, DMM Diaphragm Metering Pumps DME/DMS TECHNICAL DATA BOOKLET 1. General description, DME/DMS, DMM 1.1 Digital Dosing, DME/DMS............ 3 1.2 DMM.............................. 4 1.3

More information

Hydraulic Diaphragm type Metering Pump

Hydraulic Diaphragm type Metering Pump Hydraulic Diaphragm type Metering Pump For Metering Injection in Petr Hydraulic diaphragm metering pumps have both the high-pressure and high-precision features of plunger type pumps and zero liquid leakage

More information

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration

More information

Solenoid-driven Diaphragm Metering Pump. SM Series

Solenoid-driven Diaphragm Metering Pump. SM Series Solenoid-driven Diaphragm Metering Pump SM Series INSTALLATION, OPERATION AND MAINTENANCE MANUAL Before beginning operation, read this manual carefully! Ignoring the instructions in this IOM MANUAL and

More information

DDA AR-PVC/V/C with access.

DDA AR-PVC/V/C with access. GRUNDFOS DATA BOOKLET DDA 7.5-16 AR-PVC/V/C with access. Grundfos pump 97974077 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/ddafam/97974077/dda-7-5-16-with-access.html

More information

ProMinent Beta Solenoid Diaphragm Metering Pumps

ProMinent Beta Solenoid Diaphragm Metering Pumps Overview: Beta Ideal for basic chemical feed applications (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) ProMinent pk_1_004_1 Capacity range 0.2-8.4 gph, 232-29

More information

Dosing Pump Operational Manual

Dosing Pump Operational Manual Chemical Dosing Specialists Dosing Pump Operational Manual Pump Range WMPSP0110 - WMPSP0408 - WMPSP0607 - WMPSP0805 - WMPSP1204 - WMPSP1502 - WMPSP2001 1- Product Introduction 2 1.1 Product Overview 2

More information

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps pk_2_071 pk_2_104 Overview: Sigma/ 3 Sigma/ 3 Basic Type (S3Ba) Sigma/ 3 Control Type (S3Ca) Ideal for applications requiring automation, large turndown and/or feed verification (see page 133 for spare

More information

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LAROX PERISTALTIC PUMPS FOR METERING The innovative Larox Peristaltic Pumps for Metering (LPP-M) set a new industry standard for peristaltic pump technology.

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

ProMinent delta Solenoid Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps Overview: delta Ideal for applications requiring metering pump accuracy with minimal pulsation (see page 127 for spare parts and page 134 for control cables) Continuous or pulsating dosing Configurable

More information

User manual MTS-32. QUI-1013 Version 1.5 January

User manual MTS-32. QUI-1013 Version 1.5 January Version 1.5 January 2015 User manual MTS-32 Page 2 Contents 1. Introduction... 3 2. Principles of operation... 3 2.1 Principles of MTS-32 ventilation... 3 2.2 Principles of sorbent tube sample collection

More information

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 OPERATING INSTRUCTION Poka Patrol CNA-4mk3 Poka Patrol CNA-4mk3 To use this product properly and safely, please read this manual carefully before

More information

Pump. APLS Sanitary. Direct-driven type. Metered supply

Pump. APLS Sanitary. Direct-driven type. Metered supply Pump APLS Sanitary Direct-driven type Metered supply The Arrival of a Metering Transfer Pump with an Innovative Mechanism Ideal for Sanitary Processes! The APLS Series transfers liquids gently as it is

More information

SOLENOID DRIVEN DOSING PUMPS MX series

SOLENOID DRIVEN DOSING PUMPS MX series SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering

More information

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2-10 MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls

More information

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment Tekna Solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Five times the Flexibility A single outer casing contains 5 different models with flow rates ranging from

More information

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS TECHNICAL BROCHURE BSPDDRIVE C U L US Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS Aquavar SPD variable speed, constant pressure pump controller

More information

ECORICH. Debut of NEW ECORICH. New Products. New Launch with Full Model Change!

ECORICH. Debut of NEW ECORICH. New Products. New Launch with Full Model Change! ECORICH HYBRID HYDRULIC UNIT ECORICH New roducts New Launch with Full Model Change! Surpassing IE4 class Exceeds standard of high efficiency motor regulation. Debut of NEW ECORICH Highly efficient IM motors

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump An IDEX Water & Wastewater Business pulsafeeder.com Mechanical Diaphragm Metering Pump Pulsafeeder Expertise Since 1936, Pulsafeeder has been the global leader in fluids handling technology and innovation

More information

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive 1.1 rominent: Innovations In Chemical Feed Technology 1.1. rominent Dosing Dosierstation Station: Comprehensive Verfahrenssicher ccessory ange durch Ensures komplettes rocessing Zubehör Safety Note: Excessive

More information

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps Overview: gamma/ L Ideal for applications requiring automation, large turndown and/or feed verification (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) Capacity

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing

More information

Series PZ and PZi Pulse Metering Pumps

Series PZ and PZi Pulse Metering Pumps BULLETIN PZ-03 Series PZ and PZi Pulse Metering Pumps CHEMICAL PUMP CO., INC. US Patent #6,283,717 The Age of Intelligent Pumps Finally Arrives! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 Intelligent

More information

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes

More information

1/16 DIN Temperature Controller E5CS

1/16 DIN Temperature Controller E5CS 1/16 DIN Temperature Controller Automatic Adjustment and ID Control in a 48x48-mm ackage Control accuracy to ±1% of full scale Selectable temperature ranges in C or F Easy-to-read 13.4-mm high LED display

More information

solenoid driven diaphragm type metering pump

solenoid driven diaphragm type metering pump solenoid driven diaphragm type metering pump Affordable - Versatile - Durable The pump series covers a capacity range of 0.16 3.57 gph (0.6 13.5 l/h) at pressures 145 21 psig. Its compact construction

More information

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type ELADOS EMP III Diaphragm Pump type 00800-01200 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

An Innovative Flow Sensor

An Innovative Flow Sensor NEW Separate-amplifier type digital flow sensor FD-V7 Series An Innovative Flow Sensor PPS PFA 5 liters 2 liters 5 liters 4 liters 2 liters The debut of an innovative, Ultimate convenience has been separate-amplifier

More information

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev.

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev. E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: 54189 Revision : 00 Rev. Date: 03/2016 Note: This manual is a supplement to 54038 Table of Contents

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING! BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ DOSING PUMPS SERIE ACL - AXL - DPZ STORAGE TANKS SERIE SL WATER METER SERIE CD - CW INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization

More information

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 List of Hybrid Unit Models Various specifications for each model. DAIKIN s lineup provides a variety of functions and capacities depending on the machine type.

More information

GRUNDFOS PRODUCT GUIDE DME, DMS, DMM. Digital Dosing

GRUNDFOS PRODUCT GUIDE DME, DMS, DMM. Digital Dosing GRUNDFOS PRODUCT GUIDE DME, DMS, DMM Digital Dosing Contents General information Performance range page 4 General information, DME, DMS page 5 General information, DMM page 5 Type key page 6 Functions,

More information

Mechanical Diaphragm Metering Pump

Mechanical Diaphragm Metering Pump Mechanical Diaphragm Metering Pump sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281) 359-0084 Pulsafeeder Expertise Since 1936, Pulsafeeder

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions GRUNDFOS DATA BOOKLET Oxiperm OCD-164 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Oxiperm OCD-164 Table of contents 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

GRUNDFOS PRODUCT GUIDE. DME and DMS. Digital Dosing

GRUNDFOS PRODUCT GUIDE. DME and DMS. Digital Dosing GRUNDFOS PRODUCT GUIDE DME and DMS Digital Dosing Contents General data Performance range, DME 3 Performance range, DMS 3 Digital Dosing 4 Type key 5 Codes 5 Functions Overview of functions 6 Capacity

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

MIT515, MIT525, MIT1025, MIT1525

MIT515, MIT525, MIT1025, MIT1525 MIT515, MIT525, MIT1025, MIT1525 Measures up to 30 TΩ Safety rated up to CAT IV 1000 V to 3000 m Unique dual-case design - additional user protection Operates from battery or a.c. mains supply Rapid charge

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life ITT BRSDRIVE Goulds Pumps Simplex Variable Speed Submersible Pump Controller C U L US Engineered for life Do you want to Simplify your Commercial Pumping System? Goulds Pumps S-Drive variable speed, constant

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING!

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING! DOSING UNIT WITH TIME CONTROL DOSING PUMP WITH TIME CONTROL SERIE DCK STORAGE TANKS SERIE SL INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed,

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller ITT BSPDDRIVE Goulds Pumps Aquavar SPD (Single Pump Drive) C U L US Do you want to Simplify your Commercial Pumping System? Goulds Pumps SPD variable speed, constant pressure pump controller is designed

More information

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type ELADOS EMP III Diaphragm Pump type 00160-00540 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal

More information

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps Overview: Sigma/ 2 control type (S2Cb) The Sigma/2 motor diaphragm are produced with a high-strength inner housing for parts subject to load as well as an additional plastic housing to protect against

More information

S1-568, S1-1068, S1-1568

S1-568, S1-1068, S1-1568 S1-568, S1-1068, S1-1568 Resistance range up to 35 TΩ 8 ma noise rejection plus 4 filters Safety up to CATIV 1000V to 4000 m Rapid charge Li-ion battery meets IEC62133 Operate with flat battery from an

More information

ELADOS EMP III Diaphragm Pump type electronically controlled

ELADOS EMP III Diaphragm Pump type electronically controlled electronically controlled Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal and low level warning

More information

Hydrochloric Acid Inlet Y Strainer - Recommended for Diaphragm Pump systems.

Hydrochloric Acid Inlet Y Strainer - Recommended for Diaphragm Pump systems. roseries s CHEM-FEED s Engineered Skid Systems by Blue-White Industries, Ltd. Industries,Ind. Ltd. CHEM-FEED s CFS Single pump and dual pump systems Strong, lightweight polyester powder coated welded aluminum

More information

Manual & Automatic Chemical Control

Manual & Automatic Chemical Control Manual & Automatic Chemical Control Contents Etatron Dosing About Etatron Manual Chemical & Essence Dosing 02-03 02-03 04-07 B-V Peristaltic Pumps 04-05 PKX MA/AL Solenoid Pump 06-07 Manual Chemical Dosing

More information

Electronic Metering Pump

Electronic Metering Pump Electronic Metering Pump Pressure (PSI) Pressure (BAR) Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading the way in the development of

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

Diaphragm & Peristaltic Metering Pump

Diaphragm & Peristaltic Metering Pump Diaphragm & Peristaltic Metering Pump Pressure (BAR) Pulsafeeder Expertise Since 1936, Pulsafeeder, Incorporated has been the recognized leader in fluids handling, electronic pump controllers and systems

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

25% reduction in volume * PB1013A/Air-operated type without foot

25% reduction in volume * PB1013A/Air-operated type without foot Process Pump (Diaphragm Pump) Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Smaller, lighter, lmtop size Pa 5% reduction in volume * 11A/Air-operated

More information

motor driven metering pumps

motor driven metering pumps motor driven metering pumps DIAPHRAGM ACTUATED TYPE motor driven dosing pumps diaphragm type Welcome to FWT Dosing Systems FWT (Fluid and Water Technology) is a company formed with specialised experts

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have

More information

SA FLOW METER & FLOW SWITCH (Proximity switches are used for small flow rate)

SA FLOW METER & FLOW SWITCH (Proximity switches are used for small flow rate) SF FLOW METER & FLOW SWITCH Types: SF-M: SF-MA: Instantaneous flow indicator Instantaneous flow indicator + lower (or upper) microswitch SF-MAA: Instantaneous flow indicator + lower & upper microswitches

More information

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual INSTRUCTION MANUAL Notice 2004 Iwaki America Inc. Five Boynton Road, Holliston, MA 01746 USA tel (508) 429-1440 fax (508) 429-1386

More information

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor DX330 L/M/V SERIES Universal Intelligent Controller for Screw Air Compressor Please experience DOTECH s technology based on simplicity, multi-function and safety!! Easier Faster Safer DOTECH, INC http://www.dotech21.com

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

IWAKI METERING PUMPS AX

IWAKI METERING PUMPS AX IWAKI METERING PUMPS The highest reliability system metering Iwaki metering pumps series are compact hydraulic diaphragm pumps designed to meet the exacting requirements of modern advanced chemical processes.

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features ariety of modularized units enable selections of integrated type ejector units suitable for the application. K eries Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2 ZM Q G Y H U B C K KM J JM X XM Features acuum

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Accurate, versatile chemical pumps

Accurate, versatile chemical pumps Watson-Marlow Pumps Group has six world-class factories supported by direct sales operations in 25 countries and distributors in more than 50 countries. For contact details visit our website: www.wmpg.com

More information

motor driven metering pumps

motor driven metering pumps motor driven metering pumps DIAPHRAGM ACTUATED TYPE motor driven dosing pumps diaphragm type Welcome to FWT Dosing Systems FWT (Fluid and Water Technology) is a company formed with specialised experts

More information

Standard valves to ISO Product range overview

Standard valves to ISO Product range overview Standard valves to ISO 15218 Product range overview Function Electrical connection Voltage Manual override Page/Internet Pilot valve to ISO 15218 Width 15 mm Plug connector type C, to EN 175301-803 Plug

More information

Instruction Manual. Dosing Pump type /150l/h

Instruction Manual. Dosing Pump type /150l/h Instruction Manual Dosing Pump type 7800 60/150l/h CONTENTS Page 1. General description 4 1.1 Applications 4 1.2 Type key 5 2. Technical data 6 2.1 Mechanical data 6 2.2 Electrical data 6 2.3 Input/output

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information