Solenoid-driven Diaphragm Metering Pump

Size: px
Start display at page:

Download "Solenoid-driven Diaphragm Metering Pump"

Transcription

1 Solenoid-driven Diaphragm Metering ump

2 Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide discharge-volume range, various control functions...and many more. TACMINA's lineup of solenoiddriven diaphragm-type metering pumps, highly reliable and top-quality pumps, will answer all kinds of customers' chemical injection requirements.

3 Selection Guide by Application and Function Selection Guide Small Capacity Small Capacity S-size only S-size only Standard High-viscosity Boiler Z Manual Setting Multi Functions Z M T No-input Digital-input/output Timer Control Z Middle Capacity ZD ZI ZD Zi Advanced Functions ZD Zi4 Zi8 No-input Digital-input & Digital-Input/Output& Analog-Output Zi/ZD Large Capacity For Sodium Hypochlorite For Sodium Hypochlorite DCL Standard CL ARZ High-viscosity type CLZ Advanced Functions DCL CL CLZ AR Automatic Air-release Application DCL DCLM DCLT CL CLM CLT CLZ ARZ Digital-input/output Timer Control Digital-input/output Timer Control No-Input No-input Explanation & Corrosion-resistance Table Related Equipment & Option OTHER AR DCL/CL/CLZ

4 By Application For Injection of General Chemicals Series Small Capacity Z Manual Setting Small Capacity Multi Functions M T Middle Capacity ZD Zi Zi4 Zi8 Advanced Functions Large Capacity Advanced Functions w/ Relief Valve w/ Relief Valve Max. discharge volume Max. discharge pressure Max. allowable viscosity Relief valve function Signal Liquid-end material ml/min L/h R 1.8 R R US G/h Ma bar psi ma. s No-input R R R M T Digital-input/output Timer Control ZD No-input Zi4 Digital-input & Zi8 /VDF/SUS /VDF/SUS /VDF Reference page GO to 5 GO to 7 GO to 13 GO to 17 For Injection of Boiler / High-pressure Series Small Capacity Z Manual Setting Small Capacity Multi Functions M T For Injection of High-viscosity Chemicals Small Capacity Multi Functions M T Middle Capacity ZD ZD Large Capacity Advanced Functions w/ Relief Valve w/ Relief Valve ml/min Max. discharge volume L/h US G/h Ma Max. discharge bar pressure psi Max. allowable viscosity ma. s Relief valve function Signal Liquid-end material R R * 1 No-input M T Digital-input/output Timer Control Digital-input/output M T Timer Control No-input Reference page GO to 5 GO to 7 GO to 7 GO to 13 GO to 17 1 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of *the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.

5 For Injection of Sodium Hypochlorite Series DCL Air Block In-Line Automatic Air-release DCL DCLM DCLT CL In-Line Automatic Air-release CL CLM CLT CLZ ARZ Automatic Air-release Selection Guide w/ Relief Valve w/ Relief Valve w/ Relief Valve R R 100R 100 R R 100R ml/min Max. discharge volume L/h US G/h Ma Max. discharge pressure bar psi Max. allowable viscosity ma. s 50 Relief valve function Signal Liquid-end material DCL Digital-input/output DCLM DCLT Timer Control CL Digital-input/output CLM CLT Timer Control 100 Acrylic(MMA) R R 100R 100 No-input Reference page GO to 21 GO to 23 By Function For details on each product, see the reference page for the respective model or "Explanation" on page 26. Series Small Capacity Middle Capacity Large Capacity For Sodium Hypochlorite Function Z M T ZD Zi4 Zi8 DCL CL DCLM CLM DCLT CLT CLZ ARZ Signal (No. of ports) Digital Input Output Analog Input ower supply to Flow Checker Stroke speed Manual Discharge volume ercentage ulse-input proportional control proportional control Interval operation Auto Timer control Control Count operation(batch control) External operation-signal control External stop-signal control 2-point Level Switch control* 1 ECO mode SAFE mode Relief valve function Alarm function Memory-read error (LCD display only) Tank-level alarm w/1-point Level Switch w/2-point Level Switch Error/ Alarm ulse-input error Analog-Input error (display only) (display only) Lower discharge-volume alarm* 2 Easy calibration function Momentary discharge-volume display function* 2 (display only) 1 When 2-point Level Switch is used * 2 When Flow Checker is used *

6 Small Capacity Z Manual Setting No-input w/ Relief Valve (R/R/100R) (//100) Wide Voltage Range ower Supply AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V ( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. Simple Structure Minimum number of parts allows easy maintenance. Solenoid Discharge joint ump shaft Adjusting Dial for Easy Operation Manual adjustment from 15 to 0 pulses per minute ump head Diaphragm Dust & Water resistance Suction joint IEC standard: I65 or equivalent Avoid condensation and immersion in water. I65 Stroke-speed adjustment dial Extensive Range of Liquid-end Materials For details, refer to the "Liquid-end Material" table on the following page. w/ Relief Valve w/ Relief Valve VTCE/ Material: Application example:transfer/ inject ion of general chemicals VTCET (for injection of boiler chemicals) Material: Application example:transfer/ inject ion of boiler chemicals w/ Relief Valve FTCE/FTCF/FTCT Material: VDF Application example:transfer/ inject ion of special chemicals(e.g. strong and mixed acids) 6TCT Material: Stainless steel(sus316) Application example:transfer/ inject ion of solutions/special chemicals

7 Specification: Z Specification Max. discharge volume* 1 Max. discharge pressure* 1 Stroke speed Stroke length ml/min L/h US G/h Ma bar psi 4 x 9 Discharge side ( braided hose) Connection 6 x 8 (hose/tube: I.D x O.D) Suction side 1/4" x 3/8" Relief /air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Operation mode Manual Rated voltage ower No. of phases/frequency supply Maximum current ower consumption Weight Code R/ R/ 100R/100 VTCET VTCE FTCE FTCF FTCT 6TCT for injection of VTCE FTCE FTCF FTCT 6TCT VTCE FTCE FTCF FTCT 6TCT boiler chemicals x 8 1/4" x 3/8" 6 x 8 (FE) 1/4" x 3/8" (FE) x 8 () ( ) x 6 (nylon tube) 4 x 9 ( braided hose) to 0 strokes/min (dial setting) 6 x 11 ( braided hose) 6 x 8 1/4" x 3/8" Fixed at 1.0 mm 6 x 8 1/4" x 3/8" 4 x 6 (soft hose) 50 ma. s 6 x 8 (FE) 1/4" x 3/8" (FE) Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 AC 100 to 240 V ( 10%) 1-phase/50 or Hz 2.0 A Max.: 200 VA/Ave.: 15 W 1.7 kg x 8 () 35 to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) Less than 1,000 m Less than 85 db Setting stroke speed (15 to 0 strokes/min) w/ manual dial 6 x 11 ( braided hose) 6 x 8 1/4" x 3/8" (no freezing allowed) x 8 1/4" x 3/8" x 8 (FE) 6 x 8 1/4" x 3/8" () (FE) 1 Conditions:Clean water,room temperature. * Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". Z R VTCE 4x9 W S JL 1 (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug [for injection of general chemicals] R : ml/min (w/ Relief Valve) R : ml/min (w/ Relief Valve) 100R : 100 ml/min (w/ Relief Valve) : ml/min : ml/min 100 : 100 ml/min [for injection of boiler chemicals] R : ml/min (w/ Relief Valve) : ml/min art VTCE FTCE FTCF FTCT 6TCT VTCET Liquid-end Material ump head Diaphragm Check ball O-ring Valve seat Joint Ball stopper Item Accessory Hose/ Tube* 1 Relief /air-release hose* 1 Anti-siphon check valve * 4 x 9 6 x 11 6 x 8 E/FE/ 1/4" x 3/8" E/FE 4 x 6 A W : Standard BW : Boiler S : Standard CE : CE marking-compatible for injection of ( boiler chemicals ) EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire Also refer to the "Corrosion-resistance Table" on page 26. VTCET VTCE FTCE FTCF FTCT 6TCT EDM EDM Fluoro-rubber Special fluoro-rubber VTCE FTCE FTCF (R1/2) EDM EDM VDF ower cable (2 m) is attached. R/R/100R //100 FTCT 6TCT VDF Ceramic Special fluoro-rubber Fluoro-rubber afulo Special fluoro-rubber VDF (valve stopper) VTCET for injection of ( boiler chemicals ) 3 m Discharge side : 2 m Suction side : 1 m 1 m* 2 1 m* 2 (R1/2 or R3/8) (R1/2) Foot valve Ceramic weight * 2 Hose pump for air-release INSULOK for Relief /air-release hose* 3 1 piece 1 piece ump mounting nuts/ bolts 2 sets (M5 x ) Operation manual 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. 2 This hose is already attached to R/R/100R models. 3 This accessory is supplied with models with the simple relief valve R3 1 6 (A) EDM SUS316 SUS316 (valve stopper) External Dimension (mm) VTCE/ FTCE/FTCF/FTCT VTCET B D C E G 110 (F) (A) B C D E (F) G The shape and dimensions differ slightly depending on the liquid-end material and connection type. The mounting pitch allows mounting from 87 to 110 mm. Z

8 Small Capacity Multi Functions M T Digital-input/output Timer Control Higher Safety Three types of safety functions that realize higher rank risk management SAFE mode for preventing abnormal pressure buildup While the discharge valve is closed, the liquid transfer force is controlled to prevent pressure buildup. Relief valve function for releasing abnormal pressure When the pressure exceeds the setting value, the relief valve operates automatically. Alarm function for notifying abnormal pressure When abnormal pressure builds up due to clogging of the pipes or while the discharge valve is closed, an alarm is emitted to warn this condition. To use the SAFE mode, set the stroke length to 100%. The SAFE mode is not available for -200, boiler type and high-pressure type. The function is disabled at the factory default setting. Standard type pump discharge pressure: Ma. Boiler-type pump discharge pressure: 1.5Ma. The Relief valve function cannot be selected for SUS type, high-viscosity type, and high-pressure type pumps. When the alarm function is used together with the SAFE mode, an alarm is emitted for pressure lower than the normal pressure. This function is disabled at the factory default setting. Safety function selection flow revents abnormal pressure buildup Outputs an alarm when abnormal pressure builds up Requires a discharge pressure of Ma minimum SAFE mode SAFE mode Alarm function Relief valve function Alarm function

9 Function correspondence table /M/T DCL/DCLM/DCLT CL/CLM/CLT General chemical model High-viscosity Boiler High-pressure Sodium hypochlorite R/R/100R // /100 R R/R/100R //100 Relief valve function SAFE mode Alarm function ECO mode A circle () is indicated for the corresponding function that can be set. A cross ( ) is indicated for the corresponding function that must not be set even though it istechnically possible. Superior Eco-friendly erformance Automatically cuts power-on time in accordance with the discharge pressure High pressure 1.0Ma The power of conventional pumps was always turned on for a specific period regardless of the discharge pressure. The ECO mode of pumps always monitors operation conditions and automatically shortens the power-on time during low-pressure operation in order to reduce power consumption. 1 cycle 1 cycle 1 cycle 1 cycle ower-on time to solenoid ower consumption reduction example: - model Operating pressure: 1.0Ma Number of strokes: 0 strokes/min. Average power consumption: 18W Low pressure 0.1Ma Operating pressure: 0.1Ma Number of strokes: 0 strokes/min. Average power consumption: 8W Up to 55% reduction of power consumption Optimal Ease of Use Operability Wide power supply range Dust & Water resistance Easy maintenance I65 Simple key operations and user interface enable intuitive operation. Operation can be performed using a voltage between AC100 and 240V (±10%). IEC standard: I65 or equivalent The liquid-end parts are easy to disassemble and replace by simply detaching four bolts. Flexible installation methods High-brightness display Wide variety of liquid-end components VDF Stainless steel For high-viscosity liquids The head can be moved in three directions. The high-brightness LED is clearly visible even in low-light environments. For boiler For highpressure liquids Acrylic for sodium hypochlorite

10 ECO SAFE L Manual strokes/min 1/n ml/min STO n CAL ECO SAFE L Manual strokes/min 1/n ml/min STO n CAL ECO SAFE L Manual strokes/min 1/n ml/min STO n CAL ECO SAFE L Manual strokes/min 1/n ml/min STO n CAL Wide-ranging Control Functions Realize Ideal Chemical Injection Systems Common functions M T Manual operation Strokes/minute control The stroke speed can be set in increments of 1 stroke per minute. Discharge volume control ( only) The discharge volume can be set in increments of 0.1mL per minute. Signal distribution The following connections are possible without using a signal distributor. ulse signal You can connect multiple instances of this pump in parallel. External operation & stop control The pump can be turned on and off using a input signal from an external device. Synchronous pulse control A single pulse can be output for a single pump operation. The output pulse can be input to a second pump to perform synchronous operation. Example: For a single stroke (ump A), controls such as three strokes (ump B) and 2 strokes (ump C) can be enabled. Alarm output When the pump is used in combination with a level meter and checker, an alarm is output during abnormal pressure buildup. olyaluminum chloride Flow meter (pulse/analog) Sodium hydroxide Sodium hypochlorite Open collector or no-voltage contact signal Analog signal Analog signal 0.5 ma n pumps You can connect multiple instances of this pump in parallel. * The pumps operate in a linked manner. To operate pumps separately, install a signal distributor. 0.5mA COM mA COM 110 ulse input-based proportional control ulse frequency-division The pump performs a single injection operation for 'n' times of input pulse signals. Setting range: n = 1 to 999 Setting example: n = 3 Signal ump operation The pump performs the injection operation 'n' times for a single input pulse signal. Setting range: n = 1 to 999 Setting example: n = 3 Signal ump operation ulse frequency-magnification *1 For T, this is available only when using timer function. *1 Analog input signal-based proportional control M Automatic operation The pump operates for a specified number of strokes in the range of 0 to 0 strokes per minute in accordance with the setting value (set point, proportional band), upon receiving an analog input signal (4 to 20mA). (1) Set point (S) setting S setting range: 0 to 100% Discharge volume Fixed B, variable S (2) roportional band (B) setting B setting range: -999 to 999% Fixed S, variable B

11 Input signal Output signal Control Item Digital Number of ports Analog Type Number of ports Digital Type Manual operation Number of strokes Discharge volume control ulse proportional control Analog proportional control Timer control External operation & stop input signal (pulse type) Stop signal, pulse signal Sync pulse, alarm output 0.1 to maximum discharge volume (Enables setting in 0.1mL/minute units) M (analog type) Stop signal, pulse signal Sync pulse, alarm output 1 to 0 (Enables setting in 1-stroke units) T (timer type) Stop signal, pulse signal Sync pulse, alarm output Timer control Interval mode ump operation can be turned on and off in accordance with the setting of the timer. You can set any ON and OFF period for one pattern each in the range of 1 to 9999 minutes. Setting example: ON period: 5 minutes OFF period: 3 minutes 5 minutes 5 minutes 5 minutes DAY mode T The pump operates automatically everyday using the same ON and OFF timing that is set. You can set up to nine program patterns within the range of 0:00 to 24:00 in 1-minute unit. DAY mode cannot be used together with the WEEK mode. Setting example: ON time: OFF time: 3 minutes 3 minutes 3 minutes When both interval mode and pulse operation are simultaneously set, the pump will operate in accordance with pulse frequency-division or pulse frequency-magnification setting within the ON time set for the DAY mode and interval mode. WEEK mode The pump automatically operates every week at the same ON and OFF time being set for the day of the week. You can set one program pattern for each day of the week. You can set the ON time from 0:00 to 24:00 and OFF time within the range 0:00 to 48:00 in 1-minute unit. WEEK mode cannot be used together with DAY mode. Setting example Mon Tue Wed Thu Fri Sat Sun Mon Tue ON time Mon Time that can be set OFF time for each program ON time ump operation time Tue OFF time ON time Wed OFF time ON time Thu OFF time ON time Fri OFF time ON time Sat OFF time ON time Sun OFF time When the pulse proportional control operation is set, the pump will operate in accordance with the pulse frequency-division or pulse frequency-magnification set for this operation. When both interval mode and pulse proportional control operation are simultaneously set, the pump will operate in accordance with pulse frequency-division or pulse frequency-magnification set for this operation.*1 *1 The number of strokes will be the value set in each program. The following combination of functions can also be used besides the abovementioned combination. Interval mode External operation control DAY mode External operation control DAY mode ulse proportional control Interval mode ulse proportional control External stop control WEEK mode External stop control WEEK mode

12 code VTCE 49 W S JL Series name (discharge volume standard) Liquid-end material Hose standard (size/material) Joint specification Applicable standard ower plug : Standard (pulse input) type M: Analog input type T: Timer control type [General chemical liquid injection model w/relief valve] R : ml/min R : ml/min 100R : 100mL/min [General chemical liquid injection model] : ml/min : ml/min 100 :100mL/min 200 :220mL/min*1 [Boiler chemical liquid injection model w/relief valve*2] R : 28mL/min [Boiler chemical liquid injection model*2] : 28mL/min [High-pressure chemical liquid injection model *2] : 25mL/min erformance specifications Specification Max.discharge pressure*1 Stroke speed Stroke length Connection (hose/tube:i.d x O.D) Viscosity of transfer liquid Temperature of transfer liquid Ambient temperature Environmental resistance Insulation class ower supply ml/min L/H US G/h Ma bar psi Discharge side Suction side Air-release 4 x 9( braidedhose) 6 x 8 1/4"x3/8" VTCE FTCE FTCF FTCT 6TCT VTCET E/FE/ 1/4" 3/8" E/FE W : Standard VTCET 4 6 A : High-pressure FNT 1/4 [High-viscosity chemical liquid injection model] : ml/min V : High-viscosity 100 : 100mL/min *1 SAFE mode and ECO mode cannot be used. The information pertaining to liquid-end parts only applies to the VTCE/ type.*2 SAFE mode cannot be used. Max.discharge volume*1 Rated voltage No. of phases/frequency Max. current Max. power consumption Avg. power consumption Cable Not all model combinations are possible. When selecting the pump model, first check Specification and Liguid-end material. 4 6 A BW : Boiler S : Standard CE : CE marking -compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire /M/T R/ R/ R/ VTCE/ FTCE/FTCF FTCT 6TCT VTCET(boiler) VTCET(high-pressure) VTCE/ FTCE/FTCF FTCT 6TCT (high-viscosity) /1.0 * /1.0 * /10 * /10 * / / strokes/min (Enables setting in 1-stroke units) mm (Enables adjustment using the dial) 6 x 11( braided hose) 6 x 8 6 x 8(FE) 4 x 6(A) 4 x 6(A) 6 x 8 6 x 8(FE) 12 x 18 6 x 8() 6 x 8 6 x 8() 1/4"x3/8" 1/4"x3/8"(FE) 4 x 9( braided hose) 4 x 9( braided hose) 1/4"x3/8" 1/4"x3/8"(FE) ( braided hose) 1/4" x 3/8" 4 x 6 (soft hose) - 4 x 6 (soft hose) - 50mas or less 3,000mas or less*3 0 40(no freezing allowed) 0 40 IEC standard:i65 or equivalent (dust-&water-resistance) B AC 100 to 240 V (±10%) 1-phase/50 or Hz 2 A 2.5 A 200 VA 250 VA 15 W 18 W Cabtyre cable (510) Weight kg *1 Conditions:Clean water, room temperature.*2 Ma (7bar) for models w/relief valve(r type) whereas 1.0Ma (10bar) for models w/o relief valve. *3 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. /M/T 100R/ Specification VTCE/ FTCE/FTCF FTCT 6TCT (high-viscosity) VTCE/ ml/min Max.discharge volume*1 L/H US G/h Ma Max.discharge pressure*1 bar psi Stroke speed 1 0 strokes/min (Enables setting in 1-stroke units) Stroke length mm (Enables adjustment using the dial) Discharge side 6 x 11( braided hose) 6 x 11( braided hose) 6 x 8 6 x 8(FE) 12 x 18 Connection 6 x 8 6 x 8() 6 x 8 Suction side 1/4"x3/8" 1/4"x3/8"(FE) ( braided hose) 1/4" x 3/8" 1/4" x 3/8" (hose/tube:i.d x O.D) Air-release 4 x 6 (soft hose) - - Viscosity of transfer liquid 50mas or less 3,000mas or less*2 50mas or less Temperature of transfer liquid Ambient temperature Environmental resistance Insulation class 0 40(no freezing allowed) 0 40 IEC standard:i65 or equivalent (dust-&water-resistance) B Rated voltage AC 100 to 240 V (±10%) No. of phases/frequency 1-phase/50 or Hz ower supply Max. current Max. power consumption 2.5 A 250 VA Avg. power consumption 18 W Cable Cabtyre cable (510) Weight kg *1 Conditions:Clean water, room temperature. *2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids.

13 Control function specifications Signal Control Item Digital Manual operation ulse proportional control Analog input Input Output Number of strokes Discharge volume control Division Magnification Analog proportional control Interval DAY Timer WEEK DAY + Interval WEEK + Interval Timer + ulse Division proportional control Magnification External operation signal External stop signal Operation sync pulse Alarm output T M One port: analog signal (DC 4 to 20 ma, input resistance: approximately 110 ) One port: pulse signal One port: pump stop (no-voltage contact or open collector, signal (no-voltage maximum no. of pulses: 1200 pulses/minute, contact or open collector, minimum pulse width: 25 ms [ON period]) maximum no. of pulses: One port: pump stop signal 1200 pulses/minute, (no-voltage contact or open collector, minimum pulse width: maximum no. of pulses: 1200 pulses/minute, 25 ms [ON period]) minimum pulse width: 25 ms [ON period]) One port: solenoid sync pulse signal (DC 25 V, 10 ma or less) One port: batch warning signal (DC 25 V, 10 ma or less) 1 to 0 (Enables setting in 1-stroke units) 0.1 to maximum discharge volume (Setting in 0.1mL/min. units enabled) 1/9991/ pattern (19999min.) 9pattern 7pattern 1/9991/ roportional band/set point method Accessories Item Hose / Tube Air purge hose with relief valve*1 Anti siphonal check valve Foot valve Ceramic weight Hose pump Cable ties (INSULOK ) for relief hose (spare)*3 /M/T General chemical model Boiler High pressure High viscosity VTCE FTCE FTCF FTCT 6TCT VTCET VTCET 3m 3m 3m 3m 1 *2 1set(R1/2) 1 (R1/2 or R3/8) 1set 1set 1set 1 ower cable (2 m) is attached. Signal cable 2m ump mounting nuts / bolts 2 sets (M5x) Instruction manual 1copy *1 This hose is already attached to models with the simple relief valve. *2 This hose is not supplied with 200-type models. *3 This accessory is supplied with models with the simple relief valve. The signal cable is sold separately. The signal cable is included when the M and the chemical injection TS series are purchased as a set. Discharge side: 2 Suction side: set (R1/2) 3m External dimensions The shape and dimensions differ slightly depending on the liguid-end material and connection type. Liquid-end Material VTCE art ump head Diaphragm Check ball O-ring Valve seat acking Joint Ball stopper Valve stopper Compression coil spring Ceramic EDM EDM Ceramic Fluoro rubber Special fluoro rubber FTCE VDF Ceramic EDM EDM VDF, VDF FTCF VDF VDF Ceramic Ceramic Fluoro rubber Special fluoro rubber Special fluoro rubber VDF VDF VDF Also refer to the "Corrosion-resistance Table" on page 26. FTCT 6TCT SUS316 Ceramic SUS316 (High-viscosity) Ceramic Fluoro rubber E SUS4 VTCET (Boiler/High-pressure) Ceramic EDM, SUS4

14 Middle Capacity ZD ZD No-input Zi Advanced Functions Zi4 Zi8 Digital-input & Common Functions Direct Entry of Injection Amount The injection amount can be set according to three patterns: [By stroke speed] Setting range: 1 to 0 strokes/min (minimum setting increment: 1 stroke/min) [By discharge volume] Setting range: 0.1 to (maximum discharge volume of selected model) ml/min (minimum setting increment: 0.1 ml/min) [By percentage] Setting range: 1 to 100% (minimum setting increment: 1% (3 strokes/min)) Extensive Range of Liquid-end Materials VTCE/ Material: Application example: Transfer/ inject ion of general chemicals FTCT Material: VDF Application example: Transfer/ inject ion of special chemicals (e.g. strong and mixed acids) 20 0 Wide Voltage Range ower Supply ZD Simple Key Layout STROKE LENGTH Stroke-length adjustment dial % AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V ( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. ilot lamp LCD panel START/STO key MODE key U key DOWN key 6TCT Material: Stainless steel (SUS316. 4) Application example: Transfer/ inject ion of solutions/special chemicals 3-directional ump Head Zi STROKE LENGTH Stroke-length adjustment dial % * ilot lamp LCD panel w/ backlight* START/STO key MODE key U key DOWN key Backlight is provided only on Zi8. Separate-type Head & Controller Dust & Water resistance IEC standard: I65 or equivalent Avoid condensation and immersion in water. I65 This feature is limited depending on the operating conditions. Consult us for details.

15 ZD Quick & Easy Calibration The ZD Series is provided with easy calibration function for accurate pump calibration. Just push the button to automatically discharge 0 strokes' worth of chemical and enter the actual discharge volume that you will be measuring. This is all you need to do for accurate calibration. Zi4 Zi8 External operation & stop control The pump can be turned on and off using a input signal from an external device. Level meter Zi4 Zi8 Analog-Input roportional Control The injection amount (stroke frequency: 0 to 0 strokes/min) can be set according to the analog input signal (Zi4: 4 to 20 ma, Z i8: 0 to 20 ma or 4 to 20 ma) from an ex ter nal device. Conventional system ph meter ph C ph Control Controller INV. Zi ph meter ph C Controller Zi4 Zi8 Zi4 Zi8 Chemical liquid tank ulse-input roportional Control & External Stop Input Control ump ON/OFF can be controlled by an external stop input signal. Also, the injection amount (1/9999 to 9999 strokes/pulse) can be set according to the pulse input signal from an external device. Main piping ulse-transmitting flow meter Level Switch Zi/ZD Zi Residual Chlorine Control Zi4 Zi8 For details on the Level Switch, see "Option" on the back cover. Conventional system INV. Zi Zi8 Controller C R Residual chlorine meter Zi C Controller R Residual chlorine meter 2-point Level Switch Control Control such as alarm display and output, and pump stop is performed in accordance with the remaining amount of chemicals. 2-point Level Switch Motor Driven ump. Inverter required Zi. Inverter not required Zi8 Count (batch) & Interval (timer) Operation. Narrow control range of 1:10 (6 to Hz). Wide control range of 1:0 (1 to 0 strokes/min) Count setting 1 to 9999 strokes (x1, x10, x100, x1000) Start/Stop signal Interval setting. Raw liquid must be diluted since the discharge volume per stroke is large.. Raw liquid can be injected since the discharge volume per stroke is small. ON time : 1 to 9999 min OFF time : 1 to 9999 min Zi8

16 Specification: ZD Specification Max. discharge volume* Max. discharge pressure* Stroke speed Stroke length ml/min L/h US G/h Ma bar psi Discharge side Connection (hose/tube: I.D x O.D) Suction side Air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Operation mode ower supply Weight Manual Stroke speed Stroke length Rated voltage No. of phases/frequency Maximum current ower consumption Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input VTCE FTCT STCT VTCE FTCT STCT x 18 ( braided hose) 9 x 12 3/8" x 1/2" x 15 () to 0 strokes/min (digital setting) 0.2 to 1.5 mm (manual dial) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to x 18 ( braided hose) 9 x 12 3/8" x 1/2" 35 to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) Less than 1,000 m Less than 85 db (no freezing allowed) x 15 () Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Specification: Zi4/Zi8 Specification Max. discharge volume* 1 Max. discharge pressure* 1 Connection (hose/tube: I.D x O.D) Signal Operation mode Discharge side Suction side Air-release ml/min L/h US G/h Ma bar psi ower supply to Flow Checker* 4 ower supply Weight Digital* 3 Input Output Manual Analog-Input proportional control* 5 ulse-input proportional control* 5 Count operation (batch control) Auto Interval operation (timer control) External stop input control 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption AC 100 to 240 V ( 10%) 1-phase/50 or Hz 3.0 A Max.: 500 VA/Ave.: W 4.0 kg 4.2 kg 6.0 kg 4.0 kg 4.2 kg 6.0 kg to 0 strokes/min (digital setting) 0.2 to 1.5 mm (adjustable by manual dial) Conditions: Clean water, room temperature * VTCE FTCT STCT VTCE FTCT STCT 12 x 18 ( braided hose) 9 x 12 3/8" x 1/2" 12 x 15 () 4 x 6 (soft hose) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) Less than 1,000 m Less than 85 db Zi4 : 1 port : Analog signal (4 to 20 ma DC, input resistance: approx.110 )* 2 Zi8 : 1 port : Analog signal (4 to 20 ma DC, 0 to 20 ma, input resistance: approx. 110 )* 2 Zi4 : 1 port : High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 2 1 port : ump stop signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time)) Zi8 : 2 ports: High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 2 2 ports: Low-speed pulse signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Reset/Restart signal, Alarm reset signal, Flow Checker signal (only when Flow Checker is used), (4 selectable) Level Switch signal (only when Level Switch is used) Zi8 only : 2 ports: ulse signal (3 ma DC, 25 V or less) Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Operation end signal, Lamp alarm signal, Low tank-level alarm signal (only when 2-point Level Switch is used), (2 selectable) ulse-input error signal, Analog-Input error signal, Lower discharge-volume alarm signal (only when Flow Cheker is used) Zi8 only Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Control possible by roportional Band (B/variable range: 1 to 999%) setting/shift (S/variable range: 0 to 100%) setting Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting Zi8 only : 1 to 9999 strokes (x1, x10, x100, x1000) Zi8 only : ON time: 1 to 9999 min/off time: 1 to 9999 min "ST" flashing display, pump stopped x 18 ( braided hose) 9 x 12 3/8" x 1/2" Zi8 only : [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped AC 100 to 240 V ( 10%) 1-phase/50 or Hz 3.0 A Max.: 500 VA/Ave.: W 4.0 kg 4.2 kg 6.0 kg 4.0 kg 4.2 kg 6.0 kg * 1 Conditions: Clean water, room temperature * 2 Combined use of analog input signal and high-speed * pulse signal not possible. * 3 For a detailed explanation on signals, see "Digital Signal" on page 26. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 14. * x 15 () 4 For details on the Flow Checker, see "Option" on the back cover. 6 When 2-point Level Switch is used

17 Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". ZD 0 VTCE 12x18 W S JL (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug 0 : 0 ml/min W : Standard S : Standard 500 : 500 ml/min CE : CE marking-compatible VTCE FTCT STCT 12 x 18 9 x 12 E 3/8" x 1/2" E 12 x 15 EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire NON : No Cable Zi8 0 VTCE 12x18 W S JL Series name 2 (discharge volume standard) 3 Liquid-end material 4 Hose standard (size/material) 5 Joint specification 6 Applicable standard 7 ower plug Zi4 : Analog/ Digital-Input Zi8 : Analog/ Digital-Input & Digital-Output 0 : 0 ml/min 500 : 500 ml/min VTCE FTCT STCT 12 x 18 9 x 12 E 3/8" x 1/2" E 12 x 15 W : Standard S : Standard CE : CE marking-compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire NON : No Cable Accessory When "NON" is selected for power plug, the power cable(2m) is not provided. ZD Zi4/Zi8 Item VTCE FTCT STCT VTCE FTCT STCT Hose/ Tube* 1 Anti-siphon check valve Foot valve Ceramic weight ump mounting nuts/ bolts Operation manual (R1/2 or R3/8) * 2 3 m (R1/2) 2 sets (M5 x ) (R1/2 or R3/8) * 2 * 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table on page Only when E tube is selected * 3 m (R1/2) Zi/ZD Liquid-end Material Also refer to the "Corrosion-resistance Table" on page 26. VTCE FTCT STCT art ump head Diaphragm Check ball Ceramic VDF SUS4 O-ring EDM Fluoro-rubber Valve seat Joint Ball stopper EDM Special fluoro-rubber VDF (valve stopper) SUS4 External Dimension (mm) VTCE/ FTCT/STCT High-viscosity VTCE/ FTCT/STCT The shape and dimensions differ slightly depending on the liquid-end material and connection type. The mounting pitch allows mounting from 87 to 110 mm.

18 ON Large Capacity Advanced Functions Large-capacity Lineup of four models supporting large-capacity injection up to 1000 ml/min Max ml/min High-viscosity The series can also be used for the injection of polymer coagulant. Max. 00ma.s* When transferring high-viscosity liquids, the maximum discharge volume may be lower * than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. Direct Entry of Injection Amount The injection amount can be set according to three patterns: [By stroke speed] Setting range: 1 to 0 strokes/min (minimum setting increment: 1 stroke/min) [By discharge volume] Setting range: 0.1 to (maximum discharge volume of selected model) ml/min (minimum setting increment: 0.1 ml/min) [By percentage] Setting range: 1 to 100% (minimum setting increment: 1% (3 strokes/min)) Wide Voltage Range ower Supply AC V( 10%) There is no need to worry about site power supply voltage or voltage fluctuations since it can be used with AC100 to 240 V( 10%) power supplies. You can also keep it in stock safely since it can be used for a variety of sites and applications. Simple key Layout Stroke-length adjustment dial Dust & Water resistance IEC standard: I65 or equivalent Avoid condensation and immersion in water. I65 ilot lamp Automatic operation lamp Alarm lamp MODE key START/STO key AUTO ALARM 0 START STROKE LENGTH 100% FUNC SET RESET Large 2-row LCD display w/ backlight Function key SET/RESET key Quick & Easy Calibration The Series is provided with easy calibration function for accurate pump calibration. Just push the button to automatically discharge 0 strokes' worth of chemical and enter the actual discharge volume that you will be measuring. This is all you need to do for accurate calibration. STROKE LENGTH 100% Extensive Range of Liquid-end Materials VTCE/ Material: Application example: Transfer/injection of general chemicals (high-viscosity type) Material: Application example: Transfer/injection of high-viscosity liquids For details, refer to the "Liquid-end Material" table on the following page. FTCT Material: VDF Application example: Transfer/injection of special chemicals (e.g. strong and mixed acids)

19 Analog-Input roportional Control 2-point Level Switch Control The injection amount (stroke frequency: 0 to 0 strokes/min) can be set according to the analog input signal (4 to 20 ma DC) from an ex ter nal device. Conventional system ph Control Control such as alarm display and output, and pump stop is performed in accordance with the remaining amount of chemicals. 2-point Level Switch ph meter ph C Controller ph meter ph C Controller INV. Count (batch) & Interval (timer) Operation Residual Chlorine Control Count setting 1 to 9999 strokes (x1, x10, x100, x1000) Start/Stop signal Conventional system Interval setting INV. ON time : 1 to 9999 min OFF time : 1 to 9999 min Controller C Controller C Motor Driven ump. Inverter required R Residual chlorine meter. Inverter not required R Residual chlorine meter Example of Safe Hose iping for Fully Demonstrating the erformance of the. Narrow control range of 1:10 (6 to Hz). Wide control range of 1:0 (1 to 0 strokes/min). Raw liquid must be diluted since the discharge volume per stroke is large.. Raw liquid can be injected since the discharge volume per stroke is small. 2 Damper Anti-siphonal check valve ressure gage 3-way joint ulse-input roportional Control & External Stop Input Control 1 Relief valve Return piping ump ON/OFF can be controlled by an external stop input signal. Also, the injection amount (1/9999 to 9999 strokes/pulse) can be set according to the pulse input signal from an external device. Main piping ulse-transmitting flow meter Level Switch Suction valve (w/ built-in strainer) 1 Relief valve This valve automatically relieves excess pressure that occurs in the discharge side piping due to blockage by foreign objects and tightening of the valve to prevent accidents or possible damage to the pump and piping. 2 Damper Install a damper or air chamber when the piping is long or to suppress vibration on the piping. For details on the Level Switch, see "Option" on the back cover.

20 Specification Specification ml/min Max. discharge volume* 1 L/h US G/h Ma Max. discharge pressure* 1 bar psi Stroke speed Stroke length VTCE FTCT high-viscosity VTCE FTCT high-viscosity ( type ) ( type ) to 0 strokes/min (digital setting) 0.3 to 1.5 mm (adjustable by manual dial) Connection (hose/tube: I.D x O.D) Discharge side Suction side 12 x 18 ( braided hose) FNT 1/2 12 x 15 () FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) 12 x 18 ( braided hose) FNT 1/2 12 x 15 () FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input Signal Operation mode ower supply Weight Relief /air-release Digital* 4 Input Output Manual Analog-Input proportional control* 5 ulse-input proportional control* 5 Count operation (batch control) Auto Interval operation (timer control) External stop input control 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption * 1 Conditions: Clean water, room temperature * Code 2 ports: High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 3 2 ports: Low-speed pulse signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal, (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal 2 ports: ulse signal (10 ma DC, 25 V or less) Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal, (4 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), ulse-input error signal, Analog-Input error signal Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] (discharge volume standard) 2 Liquid-end material 3 Hose standard (size/material) 4 Joint specification 5 Applicable standard 6 ower plug 7 General [for injection of general chemicals] specification 0 : 0 ml/min 500 : 500 ml/min 700 : 700 ml/min 1000 : 1000 ml/min [High-viscosity type] 0 : 0 ml/min 500 : 500 ml/min 700 : 700 ml/min 1000 : 1000 ml/min 50 ma. s 00 ma. s* 2 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) Less than 1,000 m Less than 85 db 1 port : Analog signal (4 to 20 ma DC, input resistance: approx. 110 )* 3 VTCE FTCT Control possible by roportional Band (B) setting/set oint (S) setting Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting 12 x x 15 FNT 1/2 FNT 3/4 MNT 3/4 V 20 (Union Joint) 1 to 9999 strokes (x1, x10, x100, x1000) ON time: 1 to 9999 min/off time: 1 to 9999 min "ST" flashing display, pump stopped [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped AC 100 to 240 V ( 10%) 1-phase/50 or Hz 4.0 A Max.: 750 VA/Ave.: 100 W 11 kg W : Standard V : high-viscosity type S : Standard CE : CE marking-compatible EU : Euro plug* UL : UL plug AU : Australia plug UK : UK plug* JL : Japan lead wire 00 ma. s* 2 2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. 4 For a detailed explanation on signals, see "Digital Signal" on page When 2-point Level Switch is used * 3 Combined * use of Analog-Input signal and high-speed pulse signal not possible. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 18. * Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". 0 VTCE 12 x18 W S JL None : Standard X : Special Item Accessory Hose/ Tube* Anti-siphon check valve Strainer ump mounting nuts/ bolts(m5 x ) Operation manual VTCE The 4-pin/8-pin cable (2 m or 5 m selectable) is an option. FTCT (High-viscosity type) 3 m (R1/2 or R3/8) 4 sets For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. *

21 Specification Specification ml/min Max. discharge volume* 1 L/h US G/h Ma Max. discharge pressure* 1 bar psi Stroke speed Stroke length Discharge side Connection (hose/tube: Suction side I.D x O.D) Relief /air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Analog-Input Signal Operation mode ower supply Weight Digital* 4 Input VTCE 12 x 18 ( braided hose) FNT 1/2 50ma. s FTCT 12 x 15 () FNT 1/2 1 port : Analog signal (4 to 20 ma DC, input resistance: approx. 110 )* 3 high-viscosity ( type ) FNT 3/4 MNT 3/4 V 20 (Union Joint) 00ma. s* 2 12 x 18 ( braided hose) FNT 1/ x 15 () FNT 1/2 2 ports: High-speed pulse signal (no-voltage contact or open collector, max. number of pulses: 7500 pulse/min, min. pulse width: 4 msec (ON time))* 3 2 ports: Low-speed pulse signal (no-voltage contact or open collector, min. pulse width: 50 msec (ON time)) Signal assignments : Unassigned, ulse signal, Stop signal, Start signal, Reset/Restart signal, Alarm reset signal, (4 selectable) Level Switch signal (only when Level Switch is used), Compulsive MAX operation signal 2 ports: ulse signal (10 ma DC, 25 V or less) Output Signal assignments : Unassigned, Solenoid-operation sync pulse signal, In-operation signal, Running signal, Operation end signal, Lamp alarm signal, (2 selectable) Low tank-level alarm signal (only when 2-point Level Switch is used), ulse-input error signal, Analog-Input error signal Manual Digital settings: 3 patterns [stroke speed (1 to 0 strokes/min, in 1 stroke/min increments), discharge volume (in 0.1 ml/min increments), percentage (1 to 100%, in 1% increments)] Analog-Input Control possible by roportional Band (B) setting/set oint (S) proportional setting control* 5 ulse-input proportional Control possible by Frequency-division (1/1 to 1/9999) setting/multiplication (1 to 9999) setting control* 5 Count operation 1 to 9999 strokes (x1, x10, x100, x1000) (batch control) Auto Interval operation (timer control) ON time: 1 to 9999 min/off time: 1 to 9999 min External stop input control "ST" flashing display, pump stopped 2-point Level Switch control* 6 Rated voltage No. of phases/frequency Maximum current ower consumption ump head Diaphragm Check ball O-rings Valve seat Joint Ball stopper Ball guide Compressed coil spring VTCE/ 1000 VTCE FTCT [Low tank-level alarm] "E-02" displayed and alarm output / [Lower tank-level alarm] "ST" flashing display and pump stopped VTCE FTCT EDM EDM Fluoro-rubber Special fluoro-rubber 1 to 0 strokes/min (digital setting) 0.3 to 1.5 mm (adjustable by manual dial) Ambient temperature: 0 to 40 / Transferring liquid: 0 to to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) FTCT Less than 1,000 m Less than 85 db AC 100 to 240 V ( 10%) 1-phase/50 or Hz 4.0 A Max.: 750 VA/Ave.: 100 W 11 kg Ceramic VDF VDF (valve stopper) 50 ma. s (no freezing allowed) * 1 Conditions: Clean water, room temperature * * 3 Combined * use of Analog-Input signal and high-speed pulse signal not possible. * 5 For details, see "Analog-Input roportional Control" and "ulse-input roportional Control" on page 18. * Liquid-end Material art high-viscosity ( type ) FNT 3/4 MNT 3/4 V 20 (Union Joint) (high-viscosity type) Fluoro-rubber Special fluoro-rubber SUS4 00 ma. s* 2 2 When transferring high-viscosity liquids, the maximum discharge volume may be lower than the specified volume depending on the characteristics of the liquid and operating conditions. Consult TACMINA separately when transferring high-viscosity liquids. 4 For a detailed explanation on signals, see "Digital Signals" on page When 2-point Level Switch is used External Dimension (mm) Also refer to the "Corrosion-resistance Table" on page 26. () C B A A D E D C B A E F B A A B C D E A B C D E F 0/ /500/ /500/ A B

22 For Sodium Hypochlorite DCL DCL DCLM DCLT Digital-input/output Timer Control CL CL CLM CLT Digital-input/output Timer Control CLZ CLZ No-input Two mechanisms for preventing gas lock Easy-to-check trapped air The transparent acrylic pump head, which has an innovative design to minimize dead space, enables the operator to check the trapped air at a glance. In-line type automatic air-release mechanism DCL and CL series are equipped with an air-release mechanism designed using a new concept. The in-line air-release mechanism of these models assures the elimination of air that is trapped in the pump head and automatically prevents the discharge trouble caused by gas lock. Conventional design Air New design Chemical liquid and air Chemical liquid Air is discharged from a dedicated air purge port. Chemical liquid leaks into the air purge port side under some conditions and the discharge volume becomes unstable. Standby state The pressure inside the discharge side and pump head becomes equal and the air is compressed. Discharge process The smaller volume of air after it is compressed is discharged together with the liquid. Air block mechanism DCL series pumps are equipped with a degassing joint as standard equipment. The degassing joint prevents intrusion of air that causes gas lock. revents intrusion of maximum 15cc of air. Air Liquid Suction Air-release performance Air purge time [sec.] Comparison of the time required to purge air that is trapped in the pump head between CL and previous models (CLZD, ARZD). Test conditions (Discharge pressure: 1.0Ma, air volume: 0.1mL) Approx. 66% reduction revious model CL type revious model AR type Test conditions (Discharge pressure: 1.0Ma, air volume: 0.5mL) Approx. % reduction Unable to purge air Air purge time [sec.] revious model CL type revious model AR type revention of trouble caused by crystallization Anti siphonal check valve that prevents clogging at the injection point Injection point (no injection state) Conventional pumps DCL/CL series Main pipe (raw water) Crystallization caused by reaction between sodium hypochlorite and calcium in raw water. Main pipe (raw water) The check valve cap closes to prevent crystallization caused by reaction between sodium hypochlorite and calcium in raw water. Alarm function for notifying injection trouble When injection trouble occurs, an alarm is emitted to warn this condition. For details, see Higher Safety on page 7. Usage recaution ] When diluting sodium hypochlorite, use pure water or water processed with a water softener. Otherwise the pump may malfunction or discharge trouble may result.

23 code Not all model combinations are possible. When selecting the pump model, first check Specification and Liguid-end material. DCL ATCF 4 9 W S JL Series name Control type (discharge volume standard) Liquid-end material Hose standard (size/material) Joint specification Applicable standard ower plug DCL : Air block and in-line type automatic airrelease functions CL : In-line type automatic air-release function None : Standard (pulse input) type M : Analog input type T : Timer control type W/ relief valve R: ml/min R: ml/min 100R: 90mL/min W/O relief valve : ml/min : ml/min 100 : 90mL/min ATCF E 1/4" 3/8"E W: Standard S: Standard CE: CE marking -compatible EU:Euro plug UL :UL plug AU:Australia plug UK:UK plug JL:Japan lead wire CLZ None : No-input W/ relief valve R: ml/min W/O relief valve : 50mL/min ATCF E 1/4" 3/8"E W: Standard S: Standard CE: CE marking -compatible EU:Euro plug UL :UL plug AU:Australia plug UK:UK plug JL:Japan lead wire Specifications Specification Max.discharge volume Max.discharge pressure Stroke speed Stroke length Connection (hose/tube:i.d O.D) ml/min L/H US G/h Ma bar psi Discharge side Suction side R Air-release - Degassing joint*3 1/4" 3/8" (soft hose) Viscosity of transfer liquid Temperature of transfer liquid Ambient temperature Environmental resistance Weight kg *1 Conditions:Clean water, room temperature. *2 Ma (7bar) for models w/relief valve(r type) whereas 1.0Ma (10bar) for models w/o relief valve. *3 rovided for the DCL series only. Liquid-end materials ( braided hose) 6 8 1/4" 3/8" DCL CL CLZ R 100R 100 R R 100R 100 R R 100R ( braided hose) 6 8 1/4" 3/8" to 0 strokes/min (Enables setting in 1-stroke units) 0.51 mm (Enables adjustment using the dial) 4 9 ( braided hose) 6 8 1/4" 3/8" ( braided hose) 6 8 1/4" 3/8" 4 9 ( braided hose) 6 8 1/4" 3/8" ( braided hose) 6 8 1/4" 3/8" 4 6 (soft hose) 4 6 (soft hose) IEC standard:i65 or equivalent (dust-&water-resistance) For the power supply and the control functions, refer to the specifications of series on pages 11 and ( braided hose) 6 8 1/4" 3/8" Accessories ( braided hose) 6 8 1/4" 3/8" to 0 strokes/min (dial setting) Fixed at 1.0 mm 4 9 ( braided hose) 6 8 1/4" 3/8" ( braided hose) 6 8 1/4" 3/8" ( braided hose) 6 8 1/4" 3/8" (soft hose) mas or less 040(no freezing allowed) ( braided hose) 6 8 1/4" 3/8" ower cable(2m)is attached Item DCL CL CLZ Item DCL CL CLZ External dimensions DCL/DCLM/DCLT CL/CLM/CLT CLZ ump head Diaphragm Check ball O-ring Valve seat acking Joint Degassing joint Ball stopper AcrylicMMA Ceramic Fluoro rubber Special fluoro rubber Hose/tube Air purge hose with relief valve*1 Degassing joint Anti siphonal check valve Foot valve Cable ties (INSULOK ) for relief hose (spare)*2 Signal cable ump attachment bolts and nuts (hose already attached) 2m 3m 1m (R1/2) 1piece Operating instructions 1 copy *1 The air purge hose with relief valve is already attached to this pump. *2 This accessory is supplied for models with the relief valve (R type). The signal cable is sold separately. The signal cable is included when the M and the chemical injection TS series are purchased as a set. (120) DCL/CL/CLZ Air purge port Air purge port 76 Air purge port 1 (206) R (150.5) 87

24 For Sodium Hypochlorite AR Automatic Air-release ARZ No-input Automatic Relase of Air in ump Head Dead space inside the pump head has been limited to the bare minimum to prevent air entry and build up. Should air get into the pump, it is automatically released. Main piping Injection point Air-release piping At-a-glance Inspection of Air Entry The transparent acrylic pump head allows you to check at-a-glance if air has entered. Discharge piping Air release ARZ Air-release joint Suction piping Suction Bubbles or gas that occur in the chemical tank are sucked into the pump head. revention of Clogging at Injection oint When injecting sodium hypochlorite, it reacts with calcium in the raw water that flows through the main piping and forms crystals at the injection point. The "Anti-siphon check valve with a duck-bill cap" was developed to solve this problem. This check valve solves all of your worries when injecting sodium hypochlorite, including overfeed and siphoning. Discharge ump head Hose joint Hose joint Suction Air release The bubbles or gas pass through the Air-release joint and are fed back to the chemical tank along the Air-release piping. Discharge After all the bubbles or gas are discharged from the pump head, the chemical is discharged from the discharge side. Injection oint (when liquid is not being injected) Conventional check valve Main piping (raw water) Crystals form due to reaction with calcium in raw water. Main piping (raw water) AR The cap closes to prevent reaction with raw water and crystallization.

25 Specification Specification ml/min Max. discharge volume* L/h US G/h Ma Max. discharge pressure* bar psi Stroke speed Stroke length Discharge side Connection (hose/tube: Suction side I.D x O.D) Air-release Max. allowable viscosity Allowable temperature Ambient humidity Environmental protection Altitude of instrallation location Noise level Rated voltage ower No. of phases/frequency supply Maximum current Weight ower consumption Max. Ave The operation modes of the ARZ is the same as those for the Z, respectively x 9 ( braided hose) 6 x 8 1/4" x 3/8" 2.0 A 200 VA 15 W 1.7 kg ARZ to 0 strokes/min (dial setting) Fixed at 1.0 mm 6 x 11 ( braided hose) 6 x 8 1/4" x 3/8" 4 x 8 (soft hose) 50 ma. s Ambient temperature: 0 to 40 / Transferring liquid: 0 to 40 (no freezing allowed) 35 to 85% RH IEC standard: I65 or equivalent (dust-&water-resistance) Less than 1,000 m Less than 85 db AC 100 to 240 V ( 10%) 1-phase/50 or Hz 2.5 A 250 VA 18 W 1.8 kg Conditions: Clean water, room temperature * Liquid End Material All s art ump head Acrylic (MMA) Diaphragm Check ball Ceramic O-ring Fluoro-rubber Valve seat Special fluoro-rubber Joint Ball stopper Compressed coil spring Hastelloy C Also refer to the "Corrosion-resistance Table" on page 26. * Item Accessory Hose/ Tube* 1 Air-release hose* 1 Anti-siphon check valve Foot valve Ceramic weight ump mounting nuts/ bolts Operation manual All s 3 m 1 m (R1/2) * 2 2 sets (M5 x ) ower cable(2m)is attached * 1 For details on the hose/tube aperture, see "Connection" for the respective model in "Specification" table above. 2 Only when E tube is selected * Code Not all model combinations are possible. When selecting the pump model, first check "Specification" and "Liquid-end Material". ARZ 31 CL 4x9 W S JL Series name 2 (discharge volume standard) 3 Liquid-end material 4 Hose standard (size/material) 5 Joint specification 7 ower plug ARZ : Manual setting, No-Input 31 : ml/min CL 4 x 9 61 : ml/min 6 x : 100 ml/min 6 x 8 E 1/4" x 3/8" E W : Standard 6 Applicable standard S : Standard CE : CE marking-compatible EU : Euro plug UL : UL plug AU : Australia plug UK : UK plug JL : Japan lead wire External Dimension (mm) ARZ 83 1 R AR (202) 87 (57) (190) 118 The mounting pitch allows mounting from 87 to 110 mm.

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Diaphragm Metering ump www.tacmina.com Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Diaphragm Metering ump www.tacmina.com Safe, Easy and Long-life Relief-valve function, wide voltage range, easy operation, tough body, extensive selection of liquid-end materials, wide

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Metering Pump Features Equipped with New Functions for Higher Safety, Superior Eco-friendly Performance, and Optimal Ease of Use Higher Safety Three types of safety functions that realize

More information

Solenoid-driven Diaphragm Metering Pump

Solenoid-driven Diaphragm Metering Pump Solenoid-driven Metering Pump Features Equipped with New Functions for Higher Safety, Superior Eco-friendly Performance, and Optimal Ease of Use Higher Safety Three types of safety functions that realize

More information

Series PZ Pulse Metering Pumps

Series PZ Pulse Metering Pumps BULLETIN PZ- 22 Series PZ Pulse Metering Pumps Manual or programmable A single model accepts either pulse or milliamp signals Operates on any single-phase voltage from 94 vac through 264 vac Pump delivery

More information

Series PZ / PZi / PZiG

Series PZ / PZi / PZiG BULLETIN PZ- 8 Series PZ / PZi / Pulse Metering Pumps US Patent #6,283,717 The Power of Intelligent Pumps Expands! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 (programmable) Features MANUAL EXTERNAL

More information

Excel AD Electromagnetic dosing pump

Excel AD Electromagnetic dosing pump Flow rate Up to 7.6 l/h Pressure Up to 17.3 bar Liquid ends Acrylic, stainless steel, PP, PVC, PVDF, designed for viscous products, designed for degassing products LCD user interface with display of the

More information

Series PZ and PZi Pulse Metering Pumps

Series PZ and PZi Pulse Metering Pumps BULLETIN PZ-3 Series PZ and PZi Pulse Metering Pumps CHEMICAL PUMP CO., INC. US Patent #6,283,717 The Age of Intelligent Pumps Finally Arrives! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 Intelligent

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps Overview: Sigma/ 1 (S1Cb) The Sigma/1 motor diaphragm are produced with a high-strength inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion. The

More information

PDF-A Electromagnetic metering pumps. EHN series

PDF-A Electromagnetic metering pumps. EHN series PDF-A 0045-03 Electromagnetic metering pumps EHN series The latest electromagnetic metering pump equipped with digital controller & multi-voltage EHN Series is the latest electromagnet drive & diaphragm

More information

Diaphragm Metering Pumps

Diaphragm Metering Pumps DATA BOOK DME/DMS, DMM Diaphragm Metering Pumps DME/DMS TECHNICAL DATA BOOKLET 1. General description, DME/DMS, DMM 1.1 Digital Dosing, DME/DMS............ 3 1.2 DMM.............................. 4 1.3

More information

FLEX-PRO TM PERISTALTIC PUMPS

FLEX-PRO TM PERISTALTIC PUMPS FLEX-PRO TM PERISTALTIC PUMPS Applications Chemical Wastewater treatment Chlorination Pulp & Paper Slurries Printing inks Oil based fluids Gaseous fluids Shear sensitive fluids Caustics Chemical Slurries

More information

Solenoid-driven Diaphragm Metering Pump. SP/SA/ST Series

Solenoid-driven Diaphragm Metering Pump. SP/SA/ST Series Solenoid-driven Diaphragm Metering Pump SP/SA/ST Series INSTALLATION, OPERATION AND MAINTENANCE MANUAL Before beginning operation, read this manual carefully! Ignoring the instructions in this IOM MANUAL

More information

APL Direct-driven type

APL Direct-driven type Pump APL Direct-driven type Metered transfer Solving Trouble and Dissatisfaction of Transfer Pumps in a Single Stroke With rotary volumetric pumps and other conventional pumps, there has always been the

More information

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps Overview: Sigma/ 3 (S3Cb) The Sigma/3 motor diaphragm are produced with a high-strength metal inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion.

More information

ProMinent Beta Solenoid Diaphragm Metering Pumps

ProMinent Beta Solenoid Diaphragm Metering Pumps Overview: Beta Ideal for basic chemical feed applications (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) ProMinent pk_1_004_1 Capacity range 0.2-8.4 gph, 232-29

More information

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

PKX MA/A. Characteristics

PKX MA/A. Characteristics PKX MA/A The PKX is a PTFE diaphragm type Solenoid Metering Pump that distinguishes itself for its simplicity of use. It has proven reliability and quality and due to it compact design and versatility

More information

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps pk_2_071 pk_2_104 Overview: Sigma/ 3 Sigma/ 3 Basic Type (S3Ba) Sigma/ 3 Control Type (S3Ca) Ideal for applications requiring automation, large turndown and/or feed verification (see page 133 for spare

More information

Dosing Pump Operational Manual

Dosing Pump Operational Manual Chemical Dosing Specialists Dosing Pump Operational Manual Pump Range WMPSP0110 - WMPSP0408 - WMPSP0607 - WMPSP0805 - WMPSP1204 - WMPSP1502 - WMPSP2001 1- Product Introduction 2 1.1 Product Overview 2

More information

DLX MA/MB. Characteristics

DLX MA/MB. Characteristics DLX MA/MB The DLX range of pumps is a proven PTFE diaphragm type Solenoid Metering Pump that distinguishes itself with having a wide range of control options. Since its launch the DLX pump range has given

More information

Solenoid-driven Diaphragm Metering Pump. PZ Series OPERATION MANUAL

Solenoid-driven Diaphragm Metering Pump. PZ Series OPERATION MANUAL Solenoid-driven Diaphragm Metering Pump PZ Series OPERATION MANUAL Please read this OPERATION MANUAL carefully before use. Operating the pump incorrectly in disregard of these instructions may lead to

More information

ProMinent delta Solenoid Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps Overview: delta Ideal for applications requiring metering pump accuracy with minimal pulsation (see page 127 for spare parts and page 134 for control cables) Continuous or pulsating dosing Configurable

More information

SOLENOID DRIVEN DOSING PUMPS MX series

SOLENOID DRIVEN DOSING PUMPS MX series SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

Hydraulic Diaphragm type Metering Pump

Hydraulic Diaphragm type Metering Pump Hydraulic Diaphragm type Metering Pump For Metering Injection in Petr Hydraulic diaphragm metering pumps have both the high-pressure and high-precision features of plunger type pumps and zero liquid leakage

More information

GRUNDFOS PRODUCT GUIDE DME, DMS, DMM. Digital Dosing

GRUNDFOS PRODUCT GUIDE DME, DMS, DMM. Digital Dosing GRUNDFOS PRODUCT GUIDE DME, DMS, DMM Digital Dosing Contents General information Performance range page 4 General information, DME, DMS page 5 General information, DMM page 5 Type key page 6 Functions,

More information

DLX MA/AD. Characteristics

DLX MA/AD. Characteristics DLX MA/AD The DLX range of pumps is a proven PTFE diaphragm type Solenoid Metering Pump that distinguishes itself with having a wide range of control options. Since its launch the DLX pump range has given

More information

Solenoid-driven Diaphragm Metering Pump. SM Series

Solenoid-driven Diaphragm Metering Pump. SM Series Solenoid-driven Diaphragm Metering Pump SM Series INSTALLATION, OPERATION AND MAINTENANCE MANUAL Before beginning operation, read this manual carefully! Ignoring the instructions in this IOM MANUAL and

More information

GRUNDFOS PRODUCT GUIDE. DME and DMS. Digital Dosing

GRUNDFOS PRODUCT GUIDE. DME and DMS. Digital Dosing GRUNDFOS PRODUCT GUIDE DME and DMS Digital Dosing Contents General data Performance range, DME 3 Performance range, DMS 3 Digital Dosing 4 Type key 5 Codes 5 Functions Overview of functions 6 Capacity

More information

Diaphragm-Type Process Metering Pump

Diaphragm-Type Process Metering Pump Diaphragm-Type Process Metering Pump Z TACMINA Core Technology TACMINA is a specialist manufacturer of chemical pumps that incorporate "diaphragms" as their core technology. For about 50 years now, we

More information

DDA AR-PVC/V/C with access.

DDA AR-PVC/V/C with access. GRUNDFOS DATA BOOKLET DDA 7.5-16 AR-PVC/V/C with access. Grundfos pump 97974077 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/ddafam/97974077/dda-7-5-16-with-access.html

More information

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 OPERATING INSTRUCTION Poka Patrol CNA-4mk3 Poka Patrol CNA-4mk3 To use this product properly and safely, please read this manual carefully before

More information

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes

More information

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LAROX PERISTALTIC PUMPS FOR METERING The innovative Larox Peristaltic Pumps for Metering (LPP-M) set a new industry standard for peristaltic pump technology.

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

1/16 DIN Temperature Controller E5CS

1/16 DIN Temperature Controller E5CS 1/16 DIN Temperature Controller Automatic Adjustment and ID Control in a 48x48-mm ackage Control accuracy to ±1% of full scale Selectable temperature ranges in C or F Easy-to-read 13.4-mm high LED display

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions GRUNDFOS DATA BOOKLET Oxiperm OCD-164 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Oxiperm OCD-164 Table of contents 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING!

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING! DOSING UNIT WITH TIME CONTROL DOSING PUMP WITH TIME CONTROL SERIE DCK STORAGE TANKS SERIE SL INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed,

More information

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps Overview: Sigma/ 2 control type (S2Cb) The Sigma/2 motor diaphragm are produced with a high-strength inner housing for parts subject to load as well as an additional plastic housing to protect against

More information

ECORICH. Debut of NEW ECORICH. New Products. New Launch with Full Model Change!

ECORICH. Debut of NEW ECORICH. New Products. New Launch with Full Model Change! ECORICH HYBRID HYDRULIC UNIT ECORICH New roducts New Launch with Full Model Change! Surpassing IE4 class Exceeds standard of high efficiency motor regulation. Debut of NEW ECORICH Highly efficient IM motors

More information

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING! BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ DOSING PUMPS SERIE ACL - AXL - DPZ STORAGE TANKS SERIE SL WATER METER SERIE CD - CW INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization

More information

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps Overview: gamma/ L Ideal for applications requiring automation, large turndown and/or feed verification (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) Capacity

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Series PZ and PZi Pulse Metering Pumps

Series PZ and PZi Pulse Metering Pumps BULLETIN PZ-03 Series PZ and PZi Pulse Metering Pumps CHEMICAL PUMP CO., INC. US Patent #6,283,717 The Age of Intelligent Pumps Finally Arrives! TYPE PZ (manual) TYPE PZi4 (automatic) TYPE PZi8 Intelligent

More information

Standard valves to ISO Product range overview

Standard valves to ISO Product range overview Standard valves to ISO 15218 Product range overview Function Electrical connection Voltage Manual override Page/Internet Pilot valve to ISO 15218 Width 15 mm Plug connector type C, to EN 175301-803 Plug

More information

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2-10 MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

Hydrochloric Acid Inlet Y Strainer - Recommended for Diaphragm Pump systems.

Hydrochloric Acid Inlet Y Strainer - Recommended for Diaphragm Pump systems. roseries s CHEM-FEED s Engineered Skid Systems by Blue-White Industries, Ltd. Industries,Ind. Ltd. CHEM-FEED s CFS Single pump and dual pump systems Strong, lightweight polyester powder coated welded aluminum

More information

An Innovative Flow Sensor

An Innovative Flow Sensor NEW Separate-amplifier type digital flow sensor FD-V7 Series An Innovative Flow Sensor PPS PFA 5 liters 2 liters 5 liters 4 liters 2 liters The debut of an innovative, Ultimate convenience has been separate-amplifier

More information

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev.

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev. E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: 54189 Revision : 00 Rev. Date: 03/2016 Note: This manual is a supplement to 54038 Table of Contents

More information

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive 1.1 rominent: Innovations In Chemical Feed Technology 1.1. rominent Dosing Dosierstation Station: Comprehensive Verfahrenssicher ccessory ange durch Ensures komplettes rocessing Zubehör Safety Note: Excessive

More information

All-in-one Storage Hybrid System

All-in-one Storage Hybrid System All-in-one Storage Hybrid System The priority of power supply for battery and AC can be settable; There is no gap to switch between on-grid and off-grid in 0ms,and it will never go offline; Efficient Built-in

More information

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type ELADOS EMP III Diaphragm Pump type 00800-01200 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal

More information

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS TECHNICAL BROCHURE BSPDDRIVE C U L US Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS Aquavar SPD variable speed, constant pressure pump controller

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing

More information

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 List of Hybrid Unit Models Various specifications for each model. DAIKIN s lineup provides a variety of functions and capacities depending on the machine type.

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual INSTRUCTION MANUAL Notice 2004 Iwaki America Inc. Five Boynton Road, Holliston, MA 01746 USA tel (508) 429-1440 fax (508) 429-1386

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

GRUNDFOS DATA BOOKLET. DME and DMS DIGITAL DOSING

GRUNDFOS DATA BOOKLET. DME and DMS DIGITAL DOSING GRUNDFOS DATA BOOKLET DME and DMS DIGITAL DOSING Contents General data Performance range, DME 3 Performance range, DMS 3 DME and DMS 4 Digital Dosing 4 Type key 5 Codes 5 Functions Overview of functions

More information

Instruction Manual. Dosing Pump type /150l/h

Instruction Manual. Dosing Pump type /150l/h Instruction Manual Dosing Pump type 7800 60/150l/h CONTENTS Page 1. General description 4 1.1 Applications 4 1.2 Type key 5 2. Technical data 6 2.1 Mechanical data 6 2.2 Electrical data 6 2.3 Input/output

More information

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1) Pressure Gauge Feature The compact-size pressure gauges can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Graphical

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA MT-1 Tracer Meter RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 1 Version: 1.0 Table of Contents Important Safety Instructions...3

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump An IDEX Water & Wastewater Business pulsafeeder.com Mechanical Diaphragm Metering Pump Pulsafeeder Expertise Since 1936, Pulsafeeder has been the global leader in fluids handling technology and innovation

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Oxiperm 164 D for 30 to 2000 g/h

Oxiperm 164 D for 30 to 2000 g/h GRUNDFOS alldos product information Oxiperm 164 D for 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Measurements Measurements Standard system Front installation system 164-xxxDFI

More information

Manual & Automatic Chemical Control

Manual & Automatic Chemical Control Manual & Automatic Chemical Control Contents Etatron Dosing About Etatron Manual Chemical & Essence Dosing 02-03 02-03 04-07 B-V Peristaltic Pumps 04-05 PKX MA/AL Solenoid Pump 06-07 Manual Chemical Dosing

More information

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum

More information

High quality. Dosing pumps, BL series. Features

High quality. Dosing pumps, BL series. Features High quality Dosing pumps, BL series Features Simple operation Flow rate control High quality materials Rugged design Supplied complete The most important question one must ask when choosing a dosing system

More information

Oxiperm 164 C for 150 to 2500 g/h

Oxiperm 164 C for 150 to 2500 g/h GRUNDFOS alldos product information Oxiperm 164 C for 150 to 2500 g/h Preparation of chlorine dioxide from concentrated solutions Measurements Measurements A G C1 C B M H E F C2 C K L NaClO 2 H O 2 HCl

More information

MODEL 3567A. Digital MΩ Tester. Instruction Manual

MODEL 3567A. Digital MΩ Tester. Instruction Manual MODEL 3567A Digital Tester Instruction Manual I-01875 TSURUGA ELECTRIC CORPORATI Contents Page 1. Preface 1 1.1 Preparations prior to use 1 1.1.1 Unpacking 1 1.1.2 Storage 1 1.2 Confirmation prior to use

More information

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor DX330 L/M/V SERIES Universal Intelligent Controller for Screw Air Compressor Please experience DOTECH s technology based on simplicity, multi-function and safety!! Easier Faster Safer DOTECH, INC http://www.dotech21.com

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

Electric actuators for small valves

Electric actuators for small valves 4 895 SSC81, SSC61... Electric actuators for small valves Nominal stroke 5.5 mm SSC31 SSC81 SSC61... SSC31 SSC81 AC 24 V operating voltage 3-position control signal SSC61 AC 24 V operating voltage DC 0..10

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

GRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING

GRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING GRUNDFOS ALLDOS DATA OOKLET DIGITAL DOSING Contents General data Performance range, DME Performance range, DMS Digital Dosing Type key 5 Functions Overview of functions 6 Functional description, DME 7

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type ELADOS EMP III Diaphragm Pump type 00160-00540 Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal

More information

GALA _. Please enter ident code of the device here

GALA _. Please enter ident code of the device here Operating Instructions Manual rominent gamma/ L Solenoid Metering ump rominent GALA _ lease enter ident code of the device here lease read the operating instructions through completely before commissioning

More information

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment Tekna Solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Five times the Flexibility A single outer casing contains 5 different models with flow rates ranging from

More information

Lenntech GRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING

Lenntech GRUNDFOS ALLDOS DATA BOOKLET.  DME and DMS DIGITAL DOSING Lenntech info@lenntech.com www.lenntech.com GRUNDFOS ALLDOS DATA OOKLET DIGITAL DOSING Contents General data Performance range, DME Performance range, DMS Digital Dosing Type key 5 Functions Overview of

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

User manual MTS-32. QUI-1013 Version 1.5 January

User manual MTS-32. QUI-1013 Version 1.5 January Version 1.5 January 2015 User manual MTS-32 Page 2 Contents 1. Introduction... 3 2. Principles of operation... 3 2.1 Principles of MTS-32 ventilation... 3 2.2 Principles of sorbent tube sample collection

More information

ELADOS EMP III Diaphragm Pump type electronically controlled

ELADOS EMP III Diaphragm Pump type electronically controlled electronically controlled Mechanical stroke adjustment Stroke frequency regulation Pulse control Pulse multiplication and division Pulse memory Standard signal control Empty signal and low level warning

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

On-Premise Pro Instruction Manual

On-Premise Pro Instruction Manual On-Premise Pro Instruction Manual 0901133 Rev: A (11/13) Page 1 of 20 TABLE OF CONTENTS Introduction... 4 Features... 4 Pre-installation... 5 Installation... 5 Operating Modes... 6 Programming... 7 Load

More information

Accurate, versatile chemical pumps

Accurate, versatile chemical pumps Watson-Marlow Pumps Group has six world-class factories supported by direct sales operations in 25 countries and distributors in more than 50 countries. For contact details visit our website: www.wmpg.com

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information