WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

Size: px
Start display at page:

Download "WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C"

Transcription

1 FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD --- INSTALLED HEATER MODEL FAC FYA FCD FXC FHC 1 KFCEH001N KFCEH0501N , KFCEH01C , KFCEH001N KFCEH501C , KFCEH01N0* KFCEH001N KFCEH601C KFCEH3001F KFCEH3101C15* KFCEH301F0* KFCEH3301C0* KFCEH KFCEH , , KFCEH301F* 0, 060 0, 060 0, 060 0, , , , 006 7, KFCEH3501F30* 0, 060 0, 060 0, 060 0, , , , 006 *Intelligent Heat Staging Capable FKD FVB FEA FE5A FIG. FACTORY INSTALLED FAC, FYA HEATER MODEL MKFCEH0501N05 01, 0 MKFCEH001N0 01, 030 MKFCEH001N MKFCEH1501F FIG. HEATER MODEL FF1E 13 KFDEH001D KFDEH001D KFDEH1001D MKFDEH001D MKFDEH001D MKFDEH1001D FIG. FACTORY INSTALLED FCD FXC HEATER MODEL 11 MKFCEH0501N05 01, 0 01, 0 11 MKFCEH001N0 030, MKFCEH001N MKFCEH1501F FAN COIL WITH COOLING ONLY CONTROL Fig. Model 1 FEA / FE5A FVB / FKD FCD / FXC FAC / FYA

2 SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT HEATER VA: 1.7 HTR1 OR OR OR OR DISC DISC WD -- FAC-- 01 HTR1 ORN VIO Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Use 60 Amp class K Fuses Only, For Replacement. 6 PLUG FU HTR 60A 60A CIRCUIT BREAKER LINE FUSE EQUIPMENT GROUND HEATER TIFIER TIME DELAY ITFIER PLUG AND EPTACLE LABEL ( 3 ) REV. B Fig A07001 SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT PLUG 11 7 HTR1 6 HTR3 1. Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Use 60 Amp class K Fuses Only, For Replacement. ORN 5 ORN HEATER VA: 5.1 ORN 3 VIO HTR R E C 1 EQUIPMENT GROUND HEATER IDENTIFIER RESISTOR LABEL (3) HTR1 HTR3 FOR 3 PHASE WIRING Denotes wire to be moved for 3 phase conversion. Dashed wire (- - -) indicates wiring after conversion. 1. Disconnect E wire from limit switch 3(), cut, strip, and connect to field wire.. Disconnect LOW wire from and connect to. 3. Disconnect E wire from relay terminal and connect to. 6 ITFIER PLUG AND EPTACLE REV. B Fig A0700

3 PLUG SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT L L 1 INTERNAL PROTECTION 1 MAY BE EITHER FUSES OR CIRCUIT BREAKERS HTR1 6 HTR3 GRY GRY Use Copper Wire (75 c Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Use 60 Amp Class K Fuses Only, For Replacement. HEATER VA: 3. ORN VIO FU FU ITFIER TIME DELAY ITFIER PLUG AND EPTACLE LABEL (3) HTR1 HTR3 FU HTR L 1 60A 60A 60A 60A L FU FU CIRCUIT BREAKER LINE FUSE EQUIPMENT GROUND HEATER IDENTIFIER RESISTOR REV. B 6 WD -- FAC-- 01 Fig A07003 PLUG SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT Use Copper Wire (75 c Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. 1 Phase Heaters Are Shown Wired For Single Supply Circuit. 5. Use 60 Amp Class K Fuses Only, For Replacement. HEATER VA: 5.1 L L 1 INTERNAL PROTECTION 1 MAY BE EITHER FUSES OR CIRCUIT BREAKERS HTR3 HTR1 6 LS HTR 5 ORN VIO 3 FU GRY Fig FU R E C 6 1 IDENTIFIER RESISTOR ITFIER TIME DELAY ITFIER PLUG AND EPTACLE LABEL (3) HTR1 HTR3 L 1 60A 60A 60A 60A L LS 3 & HTR FU FU CIRCUIT BREAKER FU LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM. BLOCK HTR HEATER REV. A A0700 3

4 WD -- FAC-- 01 SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT HTR3 6 HTR1 PLUG ORN VIO HEATER VA: Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Use 60 Amp class K Fuses Only, For Replacement. LABEL ( 3 ) HTR1 HTR3 HTR EQUIPMENT GROUND HEATER ITIFIER TIME DELAY ITIFIER PLUG AND EPTACLE REV. B Fig A07005 SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT PLUG LS6 HTR6 6 LS5 HTR5 LS HTR 6 HTR3 6 HTR1 HEATER VA: Use Copper Wire (75ºc Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. 1 Phase Heaters Are Shown Wired For Single Supply Circuit. 5. Use 60 Amp Class K Fuses Only, For Replacement. ORN VIO HTR1 HTR HTR3 LS 1 & 6 GRY Fig LABEL ( 3 ) HTR6 LS & 3 HTR5 LS & HTR REV. A 0 0 EQUIPMENT GROUND HIGH VOLTAGE TERM. BLOCK HEATER ITFIER TIME DELAY ITFIER PLUG AND EPTACLE A07006

5 30KW 1PH SCHEMATIC DIAGRAM LS 6 HTR 6 HTR6 FU5 6 FU6 LS 5 HTR 5 LS HTR 6 FU LS 3 HTR 3 LS HTR 6 FU LS 1 HTR 1 WHT or PNK WHT or PNK ORN VIO GRY PLUG Use Copper Wire (75º c Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. 1 Phase Heaters Are Shown Wired For Single Supply circuit. 5. Use 60 Amp Class K Fuses Only, For Replacement. HEATER VA: 5.1 LS 1 & 6 ITFIER TIME DELAY ITFIER PLUG AND EPTACLE LABEL (3) - 1 PHASE HTR1 HTR HTR3 L5 L6 L LS & 3 1 R E C FU HTR FU5 FU6 FU FU 0 HTR5 LS & REV. A 0 0 CIRCUIT BREAKER LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM. BLOCK HEATER IDENTIFIER RESISTOR WD -- FAC-- 01 Fig A07007 SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT LS6 HTR6 FU5 6 FU6 HTR5 LS5 LS HTR 6 FU HTR3 6 FU HTR1 PLUG WHT or PNK WHT or PNK ORN VIO Use Copper Wire (75 c Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With Nec And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. 1 Phase Heaters Are Shown Wired For Single Supply Circuit. 5. Use 60 Amp Class K Fuses Only, For Replacement. HEATER VA: 5.1 ITFIER TIME DELAY ITFIER PLUG AND EPTACLE HTR1 HTR HTR3 LS 1 & 6 GRY 6 1 LABEL (3) - 3 PHASE HTR6 L5 L6 L FU HTR LS & 3 FU5 FU6 FU FU HTR5 LS & 5 LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM. BLOCK HEATER IDENTIFIER RESISTOR REV. A Fig A0703 5

6 THIS PARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM OR OR DISC DISC OR OR HTR1 SYSTEM TRANSFORMER: 0.0VA FAN COIL/HEATER:.VA REMAINING VA AVAILABLE: 31.6VA R1 WD -- FAC " DIE CUT 1" X 1/" AS SHOWN PLUG P HTR1 ORN R E C VIO A 60A V R G T C C C TRAN 0 V 30 V DIE CUT 1" X 1/" AS SHOWN F.50" HI MED LO SPT P NC FR TRAN FM GRN/ 1. Use copper wire (75*C min.) only between disconnect switch and unit.. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire.. Replace low voltage fuse with no greater than 5 amp fuse. 5. (3) speed motor shown. Optional () speed motor uses HI () and LOW ( or ). 6. Smaller heaters will have fewer components. 7. Connect R to R, G to G, etc., see outdoor instruction for details REV. A NO F R G C C C T 0 V 30 V W WHT C R WHT BARRIER INDOOR THERMOSTAT W3 E VIO W SEE NOTE #7 OUTDOOR UNIT GRY G -LOW -MED -HI GRN/- SEE NOTE #5 FM - CAP FAN MOTOR THERMALLY PROTECTED CIRCUIT BREAKER HTR HEATER CAP CAPACITOR LS LIMIT SWITCH MON LOW MARKED VOLTAGE TERMINAL F FUSE PLUG AND FM FAN MOTOR EPTACLE FIELD POWER PRINTED CIRCUIT P WIRING BOARD FR P FAN RELAY TIFIER FU LINE FUSE R RELAY EQUIPMENT TRAN TRANSFORMER GROUND UNMARKED SPT FAN SPEED TAP LOCATION TERMINAL P NC NO FR SPT MINIMUM MOTOR SPEED SELECTION FAN COIL SIZE MOTOR SPEED ONE HTR LO LO LO LO MOTOR SPEED TWO HTR LO LO LO LO LO LO LO LO Fig A0700 6

7 THIS PARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM.50" DIE CUT 1" X 1/" AS SHOWN PLUG P INTERNAL PROTECTION MAY BE EITHER FUSES OR CIRCUIT BREAKERS HTR1 HTR3 6 L R E C ORN VIO 1 L FU FU HTR1 HTR3 SYSTEM TRANSFORMER: 0.0VA FAN COIL/HEATER: 11.VA REMAINING VA AVAILABLE:.VA L 1 60A 60A 60A 60A V TRAN R G T C C C R1 R 0 V 30 V DIE CUT 1" X 1/" AS SHOWN F.50" WD -- FAC-- 01 HI MED LO SPT P NC TRAN FM GRN/ 1. Use copper wire (75*C min.) only between disconnect switch and unit.. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire.. Replace low voltage fuse with no greater than 5 amp fuse. 5. Use 60 amp class K fuses only, for replacement. 6. (3) speed motor shown. Optional () speed motor uses HI () and LOW ( or ). 7. Connect R to R, G to G, etc., see outdoor instruction for details.. If wire crimp is removed an emergency heat relay is required. (See outdoor-thermostat instructions). FR NO F R G C C C T 0 V 30 V W WHT C R WHT BARRIER INDOOR THERMOSTAT W3 E VIO W SEE NOTE #7 OUTDOOR UNIT GRY G REV. A L SEE NOTE #6 FU FU P -LOW -MED -HI GRN/- CIRCUIT BREAKER CAP CAPACITOR MON LOW VOLTAGE F FUSE FM FAN MOTOR FIELD POWER WIRING FR P FAN RELAY FU LINE FUSE EQUIPMENT GROUND SPT FAN SPEED TAP LOCATION NC NO FR SPT FM - CAP FAN MOTOR THERMALLY PROTECTED HTR HEATER LS LIMIT SWITCH MARKED TERMINAL PLUG AND EPTACLE P PRINTED CIRCUIT BOARD TIFIER R RELAY TRAN TRANSFORMER UNMARKED TERMINAL TIME DELAY TIFIER MINIMUM MOTOR SPEED SELECTION FAN COIL SIZE MOTOR SPEED AT 15 KW -- MED LO LO LO LO LO LO Fig A0700 7

8 WD -- FAC-- 01 Fig A07010

9 WD -- FAC-- 01 Fig A07011

10 WD -- FAC Motor speed selection for 01 and 0 sizes with 11 kw heater and heat pump is High. All other heater combinations is Low. when servicing REV. E Fig A

11 THIS PARTMENT MUST BE CLOSED EXCEPT FOR SERVICING CAUTION: ATTENTION: BLOWERMOTOR NOT SUITABLE FOR USE NE CONVIENT PAS AUX ROTATION ON SYSTEMS EXCEEDING INSTALLATIONS DE PLUS DE 150V TO GROUND 150 V A LA TERRE PLUG P COOLING CONTROL ONLY VIO V 0 V TRAN 30 V P STATUS M ECM P 3 ECM P 30 V PLUG GRN/ V PLUG TRAN VIO GRN P SEC SEC1 F U PLUG 5 SE PLUG GRN TROUBLE SHOOTING INFORMATION: MO TOR LED MO TOR FAULT/ACTION OFF NOT RUNNING NONE - CHECK STATUS LED OFF RUNNING MOTOR ON (FLASHING) NOT RUNNING MOTOR / HARNESS ON (FLASHING) RUNNING NONE STATUS LED FAULT / ACTION ON NONE - STANDBY MODE OFF NO LOW VOLTAGE OR CONTROL - CHECK POWER AND FUSE. 16 NO SYSTEM MUNICATIONS - CHECK WIRING OTHER REFER TO SERVICE SCREENS ON USER INTERFACE OR THE FAN COIL TROUBLESHOOTING GUIDE. A B C D OAT CWOY R HUM SYSTEM M. NON-MUNICATING OUTDOOR UNIT MOTOR SYSTEM TRANSFORMER: 0.0 VA FAN COIL:.0 VA REMAINING VA AVAILABLE: 36.0 VA 1. Use Copper Wire (75*c Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. For Use With Communicating Thermostat Only. Connect A To A, B To B, Etc. 6. Communicating Outdoor Units - Connect A To A, B To B, Etc. 7. Non-Communicating Outdoor Units - Connect R To R, Y To Y, Etc. PLUG AND EPTACLE MON EQUIPMENT GROUND ECM FAN MOTOR OAT OUTDOOR AIR THERMISTOR P PRINTED CIRCUIT BOARD P EPTACLE TRAN TRANSFORMER REV. A WD -- FAC-- 01 A0706 Fig

12 WD -- FAC-- 01 A070 Fig

13 WD -- FAC-- 01 A070 Fig

14 WD -- FAC-- 01 NOTES 1. Use Copper Wire (75ºC Min) Only Between Disconnect Switch And Unit.. To Be Wired In Accordance With NEC And Local Codes. 3. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Type Wire.. Replace Low Voltage Fuse With No Greater Than 5 Amp Fuse. 5. (3) Speed Motor Shown Optional () Speed Motor Uses HI () And LOW (E or ). 6. Connect R To R, G To G, Etc. See Outdoor Instruction For Details REV. A A0707 Fig Copyright 007 CAC / BDP D 7310 W. Morris St. D Indianapolis, IN 631 Printed in U.S.A. Edition Date: 01/07 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: WD --- FAC Replaces: FAA -W / WDFAA.1. 1

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD-INSTALLED HEATER MODEL FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL 1 KFCEH0401N03A 18,24 x 001 x 19,25 18,24 18,19,24,25 x 340816-101

More information

Wiring Diagrams (Including Accessories) (50/60 Hz)

Wiring Diagrams (Including Accessories) (50/60 Hz) UNIT 38AKS 028-044 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/230-3-60 460-3-60 575-3-60 230-3-50 346-3-50 380-3-60 400-3-50 Typical Field Wiring Electronic Programmable Thermostat, Liquid Line Solenoid

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL Wiring Diagrams 30HXA, 30HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz DIAGRAM INDEX POWER SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 1 500141 206-271 ALL 2

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 30HK040-060;30HL050,060;30HW018-040 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX UNIT 30 VOLTAGE DIAGRAM TYPE FIGURE LABEL DIAGRAM All Component Arrangement

More information

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S TANDARD FEATURE Multi -tap ECM (electronic commutating motor) motors - all sizes Integrated motor controls, with 90 -sec off TDR function, have replaced integrated circuit board Five available speed tags

More information

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL

More information

Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST , Comfort Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The and the fan coils combine the proven technology of Carrier fan coil units with either Puron, the environmentally

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

Installation Instructions

Installation Instructions 08A0, 09A0, 08A00, 08A00 For Use With Horizontal EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY HORIZONTAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

CAUTION. SMALL ROOFTOP UNITS ACCESSORY ELECTRIC HEATER AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to15TONS TABLE OF CONTENTS !

CAUTION. SMALL ROOFTOP UNITS ACCESSORY ELECTRIC HEATER AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to15TONS TABLE OF CONTENTS ! CR101A00 - CR119A00, CR264A00 - CR269A00, CR288A00 - CR299A00 CR301A00 CRSINGLE037A00 - CRSINGLE054A00 Installation Instructions SMALL ROOFTOP UNITS ACCESSORY ELECTRIC AND SINGLE POINT BOX ELECTRIC COOLING

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Installation Instructions

Installation Instructions H068A00 H069A00 H070A00 POWER EXHAUST ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 12.5to25TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 INSTALLATION... 2 Power Exhaust

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

Installation Instructions

Installation Instructions CR0A00 - CR9A00, CR264A00 - CR269A00, CR288A00 - CR296A00 CRSINGLE037A00 - CRSINGLE054A00 SMALL ROOFTOP UNITS ACCESSORY ELECTRIC AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to2---/2TONS Installation

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU

More information

Installation Instructions

Installation Instructions CALOWAMB001A00 - CALOWAMB011A00 CALOWAMB030A00 - CALOWAMB036A00 SPLIT SYSTEMS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 6to12.5TONS Installation Instructions IMPORTANT: Read these instructions

More information

Installation Instructions

Installation Instructions CRPWREXH068A00 CRPWREXH069A00 CRPWREXH070A00 POWER EXHAUST ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 25 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 INSTALLATION...

More information

Installation Instructions

Installation Instructions CRPWREXH08A0, CRPWREXH09A0, CRPWREXH08A00, CRPWREXH08A00 For Use With Horizontal EconoMi$er IV, EconoMi$er, or EconoMi$er X (W70) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... PACKAGE

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

MV Product Specifications

MV Product Specifications Product Specifications MODULAR VARIABLE SPEED BLOWER CABINET 2, 3, 4, and 5 TONS FEATURES Variable Speed modular blower Supports two stage outdoor units Dehumidification Speed: 80% Airflow Efficient low

More information

Electrical Data Supplement

Electrical Data Supplement 48HC15to25NominalTons Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R---410A) Refrigerant Sizes: 17---28 Electrical Data Supplement FOR MODELS PRODUCED ON OR AFTER JULY 30, 2012

More information

Installation Instructions

Installation Instructions 018A00 CALOWAMB023A00 CALOWAMB037A00 - CALOWAMB042A00 SPLIT SYSTEM AC UNITS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 15 & 20 TONS Installation Instructions IMPORTANT: Read these instructions

More information

Installation Instructions

Installation Instructions Smart Start Assist Kit For use with Single-Phase Residential Geothermal Heat Pumps 8-733-934-497 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY

More information

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY S NH0005 THRU NH005, NP000 THRU NP005, ND006, AND NX006 Supersedes: 0-65-003-D-05 0-65-003-E-0705 GENERAL This instruction covers the installation of

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

AC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A.

AC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A. REPAIR PARTS Models covered in this manual AC18-00C AC18-00C A AC18-05C AC18-05C A AC18-05C B AC18-06C AC18-06C A AC18-06C B AC18-08C AC18-08C A AC18-08C B AC24-00C AC24-00C A AC24-05C AC24-05C A AC24-05C

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

Parts List, Charging Chart, Wiring Diagrams

Parts List, Charging Chart, Wiring Diagrams Parts List, Charging Chart, Wiring Diagrams PHN5 24-60 SERIES 1 Phase R-410A PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST 2-5 PARTS DRAWING 6-17 CHARGING CHART 18 WIRING DIAGRAMS 19-21 Printed

More information

Installation Instructions

Installation Instructions CR101A00-CR112A00, CR103B00,CR104B00, CR113B00 - CR116B00 CR117A00-CR119A00 CR264A00-CR269A00, CR288A00-CR299A00 CR301A00,CR308A00 CR316A00-CR322A00 CRSINGLE037A00-CRSINGLE054A00 Installation Instructions

More information

Installation Instructions

Installation Instructions CRLOWAMB039A00 CRLOWAMB040A00 CRTRXKIT002A00 ACCESSORY MOTORMASTER I HEAD PRESSURE CONTROL KIT 12.5 TON HEAT PUMP Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PRODUCT USAGE... 2 SAFETY

More information

Installation Instructions

Installation Instructions 05A00 053A00 VERTICAL AND HORIZONTAL ECONOMIZER IV ACCESSORY MEDIUM ROOFTOP UNITS 5 to 5 TONS TABLE OF CONTENTS PACKAGE USAGE... SAFETY CONSIDERATIONS... PACKAGE CONTENTS... GENERAL... ACCESSORIES LIST...

More information

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY S NH0005 THRU NH005, NP000 THRU NP005, ND006, AND NX006 Supersedes: 0-65-003-A-0704 0-65-003-B-005 GENERAL This instruction covers the installation of

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz) AIR-COOLED SCREW LIQUID CHILLERS WIRING DIAGRAM New Release Form 201.19-W3 (1104) YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz) TABLE OF CONTENTS PAGE NOMENCLATURE...

More information

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB

More information

Connector Part Information. A1 LT BLU 115 Speaker Return - Right Rear A01 LT BLU 115 Speaker Return - Right Rear

Connector Part Information. A1 LT BLU 115 Speaker Return - Right Rear A01 LT BLU 115 Speaker Return - Right Rear C203 (IP HARNESS TO BODY HARN... C203 (IP HARNESS TO BODY HARNESS) (15318195 116-WAY F METRI-PACK 150,280 SERIES (BLK)) (WIRING SYSTEMS) Document ID# 358707 C203 (IP Harness to Body Harness) Connector

More information

Eclipse 2000 Service Parts

Eclipse 2000 Service Parts This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS 5-799- REV. A (/) ACCESSORY KIT INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY MODELS HE595 THRU 55 AND HH55 & 55 NOTE: Note: These heater accessories may be installed before or after the unit has been

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY MODELS THROUGH 55 AND HH5 & 55 NOTE: These heater accessories may be installed before or after the unit has been set on a curb or slab. Table

More information

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5 TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum

More information

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM Producing Quality Heating & Cooling Equipment For Over 5 Years F SERIES Floor Exposed Vertical Fan Coil Units Nominal Sizes thru 1 CFM MAGIC AIRE F SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN

More information

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current

More information

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT Fan Coils FSM4X60 DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product

More information

Installation Instructions

Installation Instructions 030A00, 031A00, 032A00 CRLOABHP001A00 48/50TC*D14, 50TCQD12, 50HCQD09, 48/50HC*D12 558/580J*14D, 548J*12, 549J*09, 551J/581J*12 RGS150, RAS150, RGH120, RAH120, RHS120, RHH102 LOW AMBIENT OPERATION MOTORMASTERR

More information

Installation Instructions

Installation Instructions PLOWAMB001A00 SMALL ROOFTOP UNITS GAS HEAT/ELETRI OOLING, ELETRI OOLING AND HEAT PUMP UNITS AESSORY MOTORMASTERR II HEAD PRESSURE ONTROLLER 60Hz 3to12---1/2tons Installation Instructions IMPORTANT: Read

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness.

More information

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2 TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2 DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness.

More information

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness.

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

P5RF Series Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

Electrical Data Supplement

Electrical Data Supplement 48/50TC 15---25 Nominal Tons Single Package Rooftop, Horizontal Air Flow Gas Heating/Electric Cooling Unit & Cooling Only/Electric Heat Unit with Puronr (R---410A) Refrigerant Sizes: 18---29 Electrical

More information

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102 INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL-15 CONTENTS GENERAL...2 NOTES, CAUTIONS AND WARNINGS........... 2 REFERENCE...2

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

ARUF Series Multi-Position

ARUF Series Multi-Position Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting

More information

34 FLASH CODE 34 - TBS LOW

34 FLASH CODE 34 - TBS LOW 34 FLASH CODE 34 - TBS LOW Section Page 34.1 DESCRIPTION OF FLASH CODE 34... 34-3 34.2 SAE J1587 EQUIVALENT CODE FOR FLASH CODE 34... 34-3 34.3 TROUBLESHOOTING FLASH CODE 34... 34-4 Figure 34-1 Turbo Boost

More information

WIRING DIAGRAM SYMBOLS

WIRING DIAGRAM SYMBOLS WIRING DIAGRAM SYMBOLS Article Text 1989 Toyota MR2 For Ace Mechanics 123 Main Street San Diego Ca 92126 Copyright 1997 Mitchell International Friday, November 28, 2003 09:15AM ARTICLE BEGINNING WIRING

More information

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

Electrical Data Supplement

Electrical Data Supplement 48TC 3 to 15 Nominal Tons Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R---410A) Refrigerant Sizes: 04---16 Electrical Data Supplement FOR MODELS PRODUCED ON OR AFTER JULY 30,

More information

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3, 3 Phase

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3, 3 Phase TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3, 3 Phase DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness.

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

Products for Indoor Air Quality and Control

Products for Indoor Air Quality and Control Products for Indoor Air Quality and Control Constant Volume Fan Powered Units AC_J Series ECM Motor Technical Guide Page 1 Table of Contents General Information Page Number ECM Motor Introduction 3 Design

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS STANDARD AIR HANDLER FORM NO. -100 (05/2014) APPLICATION 1 1/2-5 ton systems Upflow and horizontal (counterflow capable with kits) Sequenced for demand management External access

More information

1 of 37 2/25/18, 1:04 PM 2 of 37 2/25/18, 1:04 PM 3 of 37 2/25/18, 1:04 PM 4 of 37 2/25/18, 1:04 PM 5 of 37 2/25/18, 1:04 PM 6 of 37 2/25/18, 1:04 PM 7 of 37 2/25/18, 1:04 PM 8 of 37 2/25/18, 1:04 PM 9

More information

FMV156DBF FMV156DCG FMV156DQF FMV156DSF

FMV156DBF FMV156DCG FMV156DQF FMV156DSF Product No. BF CG QF SF Market North America North America North America North America Color black stainless bisque white Volts 120 120 120 120 Watts 950 950 950 950 Wiring Diagram 5995503470 5995503470

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

Installation Instructions

Installation Instructions Single Package Rooftop Cooling Only Sizes 0 --- 07 with Puronr (R---10A) Refrigerant Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS

More information

33 FLASH CODE 33 - TBS HIGH

33 FLASH CODE 33 - TBS HIGH 33 FLASH CODE 33 - TBS HIGH Section Page 33.1 DESCRIPTION OF FLASH CODE 33... 33-3 33.2 SAE J1587 EQUIVALENT CODE FOR FLASH CODE 33... 33-3 33.3 TROUBLESHOOTING FLASH CODE 33... 33-4 Figure 33-1 Turbo

More information

TECHNICAL SUPPORT MANUAL Split System Heat Pump (C,H,T)XH5

TECHNICAL SUPPORT MANUAL Split System Heat Pump (C,H,T)XH5 TECHNICAL SUPPORT MANUAL Split System Heat Pump (C,H,T)XH5 DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

A WORD ABOUT PROPER GROUNDING

A WORD ABOUT PROPER GROUNDING A Word About Proper Grounding Section 5-3 A WORD ABOUT PROPER GROUNDING Due to the wet environment of irrigation equipment, it is very important that your Pierce CP600 Center Pivot Irrigation System be

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... - - - ASCO is there for you even when you re not - SERIES - SERIES SERIES -

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL PACKAGE HEAT PUMP Models: PH242-A PH363-A PH302-A PH363-B General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

GLMV169DBF PLMV169DCG

GLMV169DBF PLMV169DCG Product No. GLMV169DBF PLMV169DCG Market North America North America Color black stainless steel Volts 120 120 Watts 1000 1000 Wiring Diagram 5995503835 5995503835 Owner's Guide TINSEB478MRR0 TINSEB478MRR0

More information

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater

More information

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT L2 L1 LOW SIDE PRESSURE PORT www.source1parts.com E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT HVAC SERVICE PARTS Supersedes:035-13604-001 Rev. E (0603) 035-13604-001 Rev. F (0104) 1

More information

Installation Instructions

Installation Instructions Installation Instructions Part No. 50DJ902791 48/50FP,JP,MP,NP 50FPX,FPY,JPX,JPY 50FB,JB,NB Accessory Outdoor-Air Cfm Kit CONTENTS GENERAL........................................ 1 INSTALLATION................................

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information