1 Product description General The automatic sliding damper AUDA is a compressed air powered damper for tight and rapid closure. Because the damper is opened and closed automatically, the extraction is always focused on the connections, extraction points or machines that for the time being are in use. This maximizes the extraction power and reduces the energy consumption. Because of this you will also have cleaner end-products and machinery, cleaner floors and a healthier working environment. AUDA complies with the requirements of the EU machinery directive (98/37/EG). Damper with mounted Reed-contact Damper with mounted microswitch Solenoid valve 1 / 6

2 Design In its standard form, the damper is made of zinc-plated steel plate but it can also be supplied in a stainless steel implementation. Installation can be carried out in an optional position. As standard, the pipe connections on the damper are equipped with clamp rims. The damper can also be delivered with a straight rim depending on the diameter (see measure table). The damper can also be delivered with connections for rolled edges or with flanges. Air tightness is achieved using flexible rubber gaskets and sealing rings. Dimensions greater than 200 mm only have sealing rings. In its standard form, the damper can cope with a maximum of +80ºC. The damper can also be supplied with sealing rings made of Teflon and will then be able to cope with a higher temperature. The damper is opened and closed by one or two compressed air cylinders, depending on the diameter. The cylinder is maneuvered by a magnetic port connected to the machinery or to a maneuver switch. With a micro switch mounted on the damper the fan can for example be turned on or off when the damper is opened or closed. 1. Pneumatic cylinder 2. Connection 1/8" - 6 mm hose 3. Hose 6 mm 4. Connection 1/8" - 6 mm hose 5. Solenoid valve 6. Silencer / adjustment 7. Cable terminal 8. Coil 230 V AC or 24 V AC/DC (other voltages are available) 9. Screw for manual operation of solenoid valve 10. Sealings 11. Damper housing 12. Damper blade 2 / 6

3 Technical data Diameter A B C Height Weight (kg) Damper blade Damper housing 50* ,3 2 1,5 63* ,3 2 1,5 76* ,0 2 1, ,0 2 1, ,3 2 1,5 102* ,3 2 1,5 108* ,0 2 1, ,0 2 1, ,0 2 1,5 127* ,0 2 1, ,0 2 1,5 152* ,0 2 1, ,2 2 1, ,2 2 1, ,2 2 1,5 202* ,2 2 1, ,5 3 2, ,5 3 2, ,1 3 2, ,1 3 2, , , , ,0 *These dampers have straight edge, all others with pull-ring edge. 3 / 6

4 Installation and maintenance NB! Service switches or lockable master switches for fans must be turned off when working with the damper. Installation When positioning the damper, the risk of personal injury must be taken into account. The damper must therefore be installed outside the working zone, e.g. at least 2.1 m above floor level. The pipe connections are, as standard, equipped with clamp rims. Installation can be carried out in an optional position but we recommend horizontal. Connecting pipe work is to be suspended in such a way that the damper is not subjected to rupturing forces. These can cause the damper to jam or become stuck. Electrical installation Before starting the electrical installation the damper must be connected to the duct work otherwise the connections on the damper should be covered securely Electrical connection must be carried out by a qualified electrician. Before Start-up 1. Check that the damper blade runs smoothly. (Should be done after the mechanical installation.) 2. Check that the damper is opened and closed when intended. Regular maintenance The damper is maintenance-free. When required, it can be cleaned using a cloth dipped in ethylated spirits. Fault finding when the damper blade is jamming or stuck 1) The damper needs to be cleaned 2) There are rupturing forces in the pipe system. (Incorrect fitting) 3) The damper blade is damaged 4) Loose sealing s 4 / 6

5 Spare parts When ordering spare parts, please specify the damper designation and size. Beteckning SPDA-01 SDPA-02 SPDA-06 SPDA-07 SPDA-08 SPDA-09 Beskrivning Solenoid valve Coil Microswitch Microswitch bracket Reed sensor Bracket for Reed sensor 5 / 6

6 Manufacturer s declaration in accordance with EU machinery directive 98/37/EG Manufacturer: Scandvent AB Tel: Box 4134 Fax: S LUND SWEDEN info@scandvent.se Automatic slide damper AUDA- Order no. The machinery may not go into service until the machine or plant it is to be included in complies with the requirements of the EU machinery directive Lund Peter Nilsson Scandvent AB 6 / 6

Cartridge filter SDFC

Cartridge filter SDFC Cartridge filter SDFC General Information: Dust collector type SDFC is a compressed air cleaned cartridge filter for continuous filtration of fine dust. The filter has a built in fan with a capacity of

More information

Cartridge filter SDCC

Cartridge filter SDCC Cartridge filter SDCC General information: Dust collector type SDCC is a compressed air cleaned cartridge filter for continuous filtration of fine dust. The collector is not suitable for filtration of

More information

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION ENGLISH This directions for use contains following products: CK

More information

INSTRUCTION MANUAL MAGNA RAIL

INSTRUCTION MANUAL MAGNA RAIL R ENGLISH NR. 148293 00 INSTRUCTION MANUAL MAGNA RAIL 1999-05-01 List of contents Declaration of conformity, CE Delivery check Mounting instruction (rail, trolley units) Mounting instruction (exhaust pipe,

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel ICP INSTALLATION INSTRUCTIONS manual outside air hood / filter (NPMANDPR004A00) (NPMANDPR005A00) and (NPMANDPR006A00) The package includes the outside air hood, the filter access door and the filter. This

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

Automation for sliding dampers, throttle valves and diverters

Automation for sliding dampers, throttle valves and diverters utomation for sliding dampers, throttle valves and diverters Page: 1/12 The circuit diagrams shown apply to stand- ard systems for sliding dampers, diverters and throttle valves. S2 Open These systems

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

Duct systems. Steel duct Galvanized. Ext. dia. mm. Length m. Material thickness mm

Duct systems. Steel duct Galvanized. Ext. dia. mm. Length m. Material thickness mm teel duct Galvanized Ext. dia. m Material thickness 050 3 m 1,25 4,5 590105003 063 3 m 1,25 5,8 590106303 076 3 m 1,50 8,3 590105003 102 3 m 1,50 11,1 590110203 108 3 m 1,50 11,8 590110803 127 3 m 1,50

More information

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX DAMPERS LSS - R LSS / SOD circular single blade shut off damper SSVent rectangular multiblade shut off damper S.Ventil R1OVL circular single blade weather tight damper/valve RD circular regulating damper

More information

BAAS Component AS 2017 Rev. 01 INSTALLATION, OPERATION AND MAINTENANCE MANUAL - DAMPERS

BAAS Component AS 2017 Rev. 01 INSTALLATION, OPERATION AND MAINTENANCE MANUAL - DAMPERS BAAS Component AS 2017 Rev. 01 INSTALLATION, OPERATION AND MAINTENANCE MANUAL - DAMPERS 1 List of Contents 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL... 3 1.1 GENERAL INTRODUCTION... 3 1.2 SCOPE...

More information

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) TABLE OF CONTENTS 1 EC Declaration of incorporation...1 2 General description...2

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Document Number 463384 VCD, FBH & FBV MODELS Vertical and Horizontal Mount Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance.

More information

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour 1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

USER MANUAL. TSK and TSK V.

USER MANUAL. TSK and TSK V. USER MANUAL TSK and TSK V www.sisteven.com Types of roof fan: TSK TSK V 1. Start All fans produced by SISTEVEN, hereinafter the manufacturer, and the full line of accessories, have been manufactured in

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

SERVICE MANUAL ULTIMATE 200

SERVICE MANUAL ULTIMATE 200 SERVICE MANUAL ULTIMATE 200 This manual is for: 20 200-120 Ultimate 200 std. 120V 60 Hz 20 200-240 Ultimate 200 std. 240V 50 Hz 20 201-120 Ultimate 200 DMX 120V 60 Hz 20 201-240 Ultimate 200 DMX 240V 50

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

Air distribution product

Air distribution product Air distribution product The company C.L.A. was established in 1975 as a manufacturer company of air conditioning system components. Among its customers: dealers, air handling units producers and fans

More information

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

ASSEMBLY INSTRUCTIONS L-LINE KTG ZMA0304GB

ASSEMBLY INSTRUCTIONS L-LINE KTG ZMA0304GB ASSEMBLY INSTRUCTIONS L-LINE KTG ZMA0304GB 2012-12-01 Delivery information Goods inspection Check that the number of packages agrees with the delivery note and that the packing and goods are not damaged.

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

NSDZ. Swirl diffusers with adjustable air control blades

NSDZ. Swirl diffusers with adjustable air control blades Swirl diffusers with adjustable air control blades NSDZ The diffusers NSDZ are intended to use in low- and medium-pressure ventilation systems. They allow for obtaining the swirl air flow and are especially

More information

operating instruction

operating instruction operating instruction a.560pn #125101 DE, EN, FR, SE Table of Contents Installation... 3 Tool use...4-5 Safety precautions...6-7 Troubleshooting and maintenance... 8 Technical specification... 9 Spare

More information

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage CONTROL UNITS LOCAL EXTRACTORS Fumex s control unit offers a good working environment, adapted to all types of facilities. The right choice of control units is also very energy-saving and provides the

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

SMOKE CONTROL DAMPERS

SMOKE CONTROL DAMPERS SMOKE CONTROL DAMPERS 96 - CPD - 0058 Round DKIR and Rectangular DKIS ORIGINAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! /

More information

Maintenance Information

Maintenance Information Form 16575334 Edition 1 April 2005 Electric Screwdrivers EL, EP and ET 34V DC Series Maintenance Information Save These Instructions WARNING Maintenance procedures have the potential for severe shock hazard

More information

AXIAL FANS Axis / Tubo OPERATION MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Knife gate valve SLF. Data is only for informational purpose. All specifications are subject to change without notice issue 3

Knife gate valve SLF. Data is only for informational purpose. All specifications are subject to change without notice issue 3 Knife gate valve SLF Data is only for informational purpose. All specifications are subject to change without notice. V R 1 2013-02-15 issue 3 Knife gate valve SLF Stafsjö s knife gate valve SLF is a flanged

More information

USER MANUAL. WINN CUT Edger. Read the instructions carefully and understand them before using WinnCut.

USER MANUAL. WINN CUT Edger. Read the instructions carefully and understand them before using WinnCut. USER MANUAL WINN CUT Edger Distributed by: Becker Arena Products Inc. www.beckerarena.com 800-234-5522 Read the instructions carefully and understand them before using WinnCut. This manual contains important

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS 4080 SE International Way. Suite B110, Milwaukie, OR 97222 (503) 654-0867 Fax: (503) 654-4671 email: ftech@filtertechnologyltd.com www.filtertechnologyltd.com DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE)

More information

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury

More information

S E LV Butterfly Valves VA

S E LV Butterfly Valves VA VALVES Butterfly Valves VNE 2 SPECIFICATIONS BUTTERFLY VALVES B SERIES BUTTERFLY VALVES BUTTERFLY VALVES... Butterfly Valves are available in Manual, Air Actuated, or Air Actuated with two Micro switches

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0517 - Iss 5 INTRODUCTION Thank you for selecting this Clarke Electric Hoist.

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

SLV EN 1092 PN 10 ANSI B16.5 Class 150 AS 2129 Table D AS 2129 Table E

SLV EN 1092 PN 10 ANSI B16.5 Class 150 AS 2129 Table D AS 2129 Table E SLV EN 2 PN ANSI.5 Class 0 AS 2 Table D AS 2 Table E Stafsjö s knife gate valve SLV is bi-directional and designed for the most demanding slurry and abrasive applications. It is a full bore valve with

More information

UNI EN ISO EN

UNI EN ISO EN Airplus Safeline eneral Upon implementation of the AIRPLUS T series, air-treatment units, PNEUMAX develops a supply and discharge valve, with an electropneumatic control and spring-return, fitted with

More information

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL... 1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

INSTRUCTION MANUAL ENGLISH CAPTURE AT SOURCE FILTERMAX NR /

INSTRUCTION MANUAL ENGLISH CAPTURE AT SOURCE FILTERMAX NR / INSTRUCTION MANUAL ENGLISH CAPTURE AT SOURCE NR. 898 / -9- Installation Operating Starting Settings Service Repair Accessories Protocols List of contents CE, Declaration of conformity Delivery check IMPORTANT!

More information

Troubleshooting flow chart for power unit M3593

Troubleshooting flow chart for power unit M3593 Troubleshooting flow chart for power unit M3593 - Motor does not operate. - Motor operates continuosly - Snow plow does not raise. - Snow plow raises up very slow. - Snow plow will not lower. - Snow plow

More information

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator. POWERS Controls No. 6 Pneumatic Damper Actuator Technical Instructions AP 331-3 331-2793 Actuator 331-2857 Actuator with Clevis and Pin 331-3012 Extended Shaft and Frame Mounting Description The POWERS

More information

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR MANAGEMENT FIRE DAMPERS ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE 2 ETPR-E-1 Fire damper Technical catalogue Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the

More information

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC DCV-LC Lab climate control External occupancy detector Lab climate control unit 24VAC + Communication Occupancy DCV-LC 24VAC + Communication AIN Adjustable function AOUT Adjustable function SMART DAMPERS

More information

Guidelines for inspection and servicing. VBG MFC coupling 2018

Guidelines for inspection and servicing. VBG MFC coupling 2018 Guidelines for inspection and servicing VBG MFC coupling 208 General information General The components used to connect a vehicle and trailer are exposed, even during normal use, to very high tensions.

More information

INSTALLATION INSTRUCTIONS 3-POSITION GATE VALVES SIZES Read All Instructions Prior To Installation

INSTALLATION INSTRUCTIONS 3-POSITION GATE VALVES SIZES Read All Instructions Prior To Installation Read All Instructions Prior To Installation MODEL NUMBER: SERIAL NUMBER: UNPACKING Inspect shipping container before unpacking for damages sustained during transit. Any visible damage should be reported

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD Instruction Manual SBV Sanitary Ball Valve TD 451-013 ESE01782-EN7 2016-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

BIG Pressure switch. Products. Functioning. The device change the electric contact condition on the working characteristic pressure be attainment.

BIG Pressure switch. Products. Functioning. The device change the electric contact condition on the working characteristic pressure be attainment. BIG Pressure switch MTM Hydro srl Components and accessories for h.p. cleaners and car wash Via Moglia, 33-12062 Cherasco (CN) tel. (+39) 0172.49.59.30 - fax (+39) 0172.49.54.37 www.mtmhydro.it - info@mtmhydro.it

More information

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-.. Operating Instructions for Polysulfone Paddle Monitor Model: -.. 1. Contents 1. Contents... 2 2. Note... 3 3. Regulation Use... 3 4. Operating Principle... 3 5. Instrument Inspection... 4 6. Mechanical

More information

Marine Fire and Gas Dampers

Marine Fire and Gas Dampers M 3.2/2/EN/ 2 Marine Fire and Gas Dampers Type JFD Telephone + 6 06-678 8188 Telefax + 6 06-678 8288 / 388 E-mail enquiry@troxapo.com www.troxapo.com Contents Description Description 2 Accessories 6 Construction;

More information

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS MicroStart IBC control PAGE REFERENCE Functional description 1 Technical data 2 Functions 2-3 - Push-button - DIP-switches - Operation indications - Alarm

More information

Push-Pull Slide Gate - Series E

Push-Pull Slide Gate - Series E Push-Pull Slide Gate - Series E For Gravity Flow Applications and Vacuum LSP Flanged Top View Available in sizes 2" to 12" Side View Bolt Thru Pipe Flange Connection Top View Stainless steel material contact

More information

SERVICE MANUAL. Chairman. Playman/Robo

SERVICE MANUAL. Chairman. Playman/Robo SERVICE MANUAL Chairman Playman/Robo US How to contact Permobil Permobil Inc. USA 6961 Eastgate Blvd. Lebanon, TN 37090 USA Phone: 800-736-0925 Fax: 800-231-3256 Email: info@permobilusa.com Head Office

More information

Stafsjö Valves AB. SE Stavsjö, Sweden. Tel: +46 (0) Fax: +46 (0) A Bröer Group company

Stafsjö Valves AB. SE Stavsjö, Sweden. Tel: +46 (0) Fax: +46 (0) A Bröer Group company Product: W W Stafsjö s knife gate valve W is a bi-directional valve with full bore. It is made to handle different liquids, especially in water, waste water and biogas plants. The W valve is designed of

More information

1mm GALVANIZED PIPE SYSTEM

1mm GALVANIZED PIPE SYSTEM 1mm GALVANIZED PIPE SYSTEM Product group 1 A modular pipe system Download catalogue 1mm GALVANIZED PIPE SYSTEM Product group 1 v.en.04/2013 Content Assembly methods... 1-8 Pipes... 9-12 Bends... 13-14

More information

delivering pure air for 60 years in all weathers, and improv all the while DLSE + VAV System

delivering pure air for 60 years in all weathers, and improv all the while DLSE + VAV System ! ential, Airwell Resid delivering pure air for 60 years in all weathers, ing and improv all the while DLSE + VAV System 19 20 22 23 24 18 2016 Room by room control [ ZONE CONTROLLER ] q The zone controller

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter

More information

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN PROUDLY MADE IN R38089 THE USA Classified by UL to UL 2043 for heat release rate and smoke optical density. ABV-4 ABV-5 ABV-6 Product Information The ABV Automatic Balancing Valves maintain a constant

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)

KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607) KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York 14901 Telephone (607) 734-2211 Fax (607) 734-3288 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL General ECCENTRIC PLUG

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

SERVICE BULLETIN REFERENCES 1983

SERVICE BULLETIN REFERENCES 1983 J a I) SERVICE BULLETIN REFERENCES 1983 19.35 TROUBLE SHOOTING Engine Won t Start or Hard Starting Possible Cause ALL MODELS No fuel in tank. Fuel valve off. Insufficient or excessive priming. Spark plug

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

Extraction arm FX100 Original

Extraction arm FX100 Original Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories,

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

Pneumatic Axial Fan Type Tech. Doc. No. 802

Pneumatic Axial Fan Type Tech. Doc. No. 802 Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: 06.08.13 815340300_en_Version_02 Page 1 of 11 ATTENTION!!! This pneumatic

More information

Safety Instructions. Series 3 E. for Installation, Operation and Maintenance of ABO Buteerfly Valves

Safety Instructions. Series 3 E. for Installation, Operation and Maintenance of ABO Buteerfly Valves Safety Instructions for Installation, Operation and Maintenance of ABO Buteerfly Valves Series 3 E 1 1. All safety instructions should be read carefully; otherwise all manufacturer's warranties become

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA 96 - CPR - 0 ORIGINAL INSTALLATION, MAINTENANCE AND OPERATION MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! / PP-5_0604 DKISMA

More information

Two seal rings will be installed in each piston groove, total of four rings installed in each piston.

Two seal rings will be installed in each piston groove, total of four rings installed in each piston. When seals removal is complete, piston grooves will have exposed metal with no seals. Wipe clean piston grooves (towel). Repeat seals removal for second piston. Note: Deteriorated O-rings will be flattened

More information

Installation TBBD mixing section GOLD/SILVER C SD

Installation TBBD mixing section GOLD/SILVER C SD Installation TBBD mixing section GOLD/SILVER C SD 1. General The TBBD mixing section is available for the GOLD/SILVER C SD in sizes 04-80. The mixing section can be used when it is desirable use recirculated

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010 ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS LS1010 INTRODUCTION Thank you for purchasing this CLARKE Electric Hoist. Before attempting to use

More information

3 PORT MOTORISED VALVE (22 mm)

3 PORT MOTORISED VALVE (22 mm) Salus SBMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 10:56 Page 1 3 PORT MOTORISED VALVE (22 mm) Model No SBMV32 Instruction Manual Salus SBMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 10:56 Page 2 2

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Snow blade SRM-FB 120 CD Angle adjustment mechanical Version

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

The New Filter Valve Technology

The New Filter Valve Technology The New Filter Valve Technology HIGH FLOW, QUICK RESPONSE.. Connections Ports available in NPT, and BSPP G thread to international standards Response Minimized space above the diaphragm guarantees fast

More information

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD Instruction Manual Magnetic Mixer MM UltraPure TD 531-001 ESE01696-EN5 2015-05 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V) INSTRUCTION MANUAL AMS 4000 One Piece Negative Pressure Unit (AMS-4000 NPU 230V) Page 1 of 19 WARNING Asbestos exposure can cause severe and fatal diseases. Approved Code of Practices should be applied

More information

BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions

BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions BKV 4000 Bottom Blowdown Control Valve Installation and Operating Instructions BKV 4000 MKK v10.01-en 1 CONTENTS 1. SAFETY INFORMATIONS... 3 2. DESCRIPTION... 3 3. TECHNICAL SPECIFICATIONS... 4 3.1. BKV

More information

Troubleshooting Manual

Troubleshooting Manual Troubleshooting Manual NOTICE: DO NOT DISCARD THIS MANUAL Models: LEGACY42-IFT PHOENIX42-IFT 1 TABLE OF CONTENTS A. Normal Operation...3 B. Wiring Diagram...4 C. Troubleshooting IntelliFire Touch...5 D.

More information

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electrically Released Brakes ERS VAR11-01 FT = 4100 N SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC

More information