Electrically Released Brakes ERS VAR11-01 FT = 4100 N
|
|
- Jack Patrick
- 5 years ago
- Views:
Transcription
1 SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing TUV SUD Industrie Service WARNER ELECTRIC EUROPE Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex Tél. +33 (0) , Fax + 33 (0)
2 Declaration of conformity: During the design of this product, the EU directives applicables were taken into account. An attestation of conformity is available on request. For Incorporating the product, the manufacturer of a machine or system need to take into account the EU directives applicables. Summary of the directives and standards used: Directives: 2006/95/EC Low voltage equipment directive 95/16/EC Lifts directive 2004/108/EC Electromagnetic compatibility directive Standards: DIN VDE 0580 Electromagnetic devices and components, General requirements EN 81-1 Safety rules for the construction and installation of lifts - Part 1: Electric lifts NFC Industrial electrical apparatus. Electromagnetic apparatus for mechanical applications. Requirements. CONTENTS 1 Technical specifications 2 2 Precautions and restrictions on use Restrictions on use Precautions and safety measures 3 3 Installation Transport - storage Handling Montage Hand lever configuration Installation 4 1 Technical specifications Hand release 4 Maintenance Adjusting the airgap Adjusting the microswitch Brake exchange 5 5 Electrical connection Important recommendations Grounding Connector / free wires 6 6 Spare parts 7 7 Tools 7 8 Troubleshooting 7 Airgap Grounding screw M5 Friction pads Counternuts Screws for airgap adjustment Holes for mounting pins Table 1 Warner Electrie Reference Fig. 1 Detection screw, stroke measure Fig. 2 ERS VAR11-01 FT = 4100 N Customer s friction disc Nominal static torque Nm (See curve on customer s drawing) Maximum linear speed m/s 10 (outside diameter of the disc) Nominal airgap mm 0,35 Maximum airgap after wear mm 0,6 Overexcitation voltage (+5% /-10%)(1sec) VDC 103,5 207 Holding voltage (+5% /-10%) VDC ,5 Power (holding) (20 C) W 44,4 51 Power (overexcitation) (20 C) W Cyclic duration factor (%) ED 60 Weight kg 14,3 Maximum force on the hand lever N 1000 WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 2/7
3 Symbol designating an action that might damage the brake Symbol designating an action that might be dangerous to human safety Symbol designating an electrical action that might be dangerous to human safety 2 Precautions and restrictions on use 2.1 Restrictions on use For the brake to comply with directive 95/16/ EC, the integrator must observe the general conditions for installation, as stated in the EC type-examination certificate ref. ABV775/1 of 03/05/2010 from TÜV SÜD Industrie Service. These brakes are designed to work in dry conditions. Any contact with oil, grease, water or abrasive dust causes a decrease in torque. Warning : It is the responsibility of the customer to install the necessary protection to prevent pollution of the friction surfaces and to ensure that these same friction surfaces are thoroughly degreased and clean before mounting the brake. Torque subject to decrease in case of water contamination. Warning : brake must be replaced after water contamination. This product is not suitable for use according to ATEX/94/9/EC. These units are designed for use in an ambiant temperature between 0 C and +40 C maximum. Warning : at low temperature, any freezing of the friction face, due to condensation, generates a loss of torque. It is the responsability of the customer to take measures to avoid this problem. It is mandatory to follow instructions and datas given in documentation and marking of the units, in order to ensure the performance of the brake. This brake may only be used in a horizontal axis. The customer must be careful not to alter the factory-set airgap and the working clearance of the brake and the hand lever. Protection class: Mechanical : IP10 Electrical : IP54 Insulation class: F 155 C This brake is designed for static applications. Any dynamic braking is restricted to emergency braking and test braking. This brake can in no way replace the safety braking system used during lift descent. Nominal torque is reached by burnishing of brake in customer plant. Recommended: permanent sliding 11 RPM during 300 s. If maximum rotation speeds are exceeded, the guarantee is no longer valid. When switching on DC-side the coil must be protected against voltage transients. 2.2 Precautions and safety measures During maintenance, make sure that the mechanism to be braked by the brake, is stopped and that there is no risk of it accidentally starting up. All intervention have to be made by qualified personnel, owning this manual. Any modification made to the brake without the express authorisation of a representative of Warner Electric, in the same way than any use out of the contractual specifications accepted by "Warner Electric", will result in the warranty being invalidated and Warner Electric will no longer be liable in any way with regard to conformity. 3 Installation 3.1 Transport / storage These devices are delivered in a package guaranteeing the preservation of the product providing it is by surface transportation. In case of a specific request (air or sea transport, long-term storage, etc) contact our factory. 3.2 Handling Avoid any impact to the brake so that its performance is not impaired. Never lift the brake by its cables 3.3 Installation mounting In case of long storage, check the brakes, before setting the drives, in order to avoid, in case of large temperature variation, any risk of sticking from the friction material, able to hindrance the start of the drive. Data for customer friction disc: Material: steel (150 to 250 HV) or cast iron, thickness of the friction disc: 15 mm +0/-0,1, roughness of the friction faces: Ra 1,6. Protection: dry phosphatizing or Nitriding. Geometric tolerances: 0,1 Friction face / Pulley axis 0,1 WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 3/7
4 Data for mounting pins: Material: steel (min. 900 N/mm2), diameter 25h8, roughness: Ra 0.8. Protection: dry phosphatizing or Nitriding 0,1 Support axis / Pulley axis Engage the brake, armature attracted under voltage or with hand release, on his disc. Mount the mounting pins, then the connecting bar and tighten with the indicated torque for the locknuts Hand lever configuration According to the hand lever side of actuation, the customer must fit the pins, for limitation of the hand lever travel, in the selected position. Dimension of the pin out of the magnet: 6 max. (see Fig. 7). Release right 4 Maintenance 4.1 Adjusting the airgap Check the airgap at each maintenance inspection. Reminder: This brake is intended for a static application as a safety brake. Any dynamic braking is restricted to emergency and test braking. Normal use will not lead to any noticeable wear on the lining. Fig. 3a Release left The airgap adjustment must be reset before the max. airgap is reached. This to eliminate any functional problems because of the hand release travel. Slide two feeler gauges 0,3 mm thick in the airgap, avoiding the dampers, between the armature and the magnet (Fig. 5). Energize magnet. Screw Friction pad Nut Armature Fig. 3b Airgap Disc Installation The brake is delivered pre-assembled with pre-set microswitches and airgaps. Hand release Connecting bar Counternut Feeler gauge Feeler gauge Fig. 5 Tighten the airgap adjusting screws H M12 (18 A/F), until you reach contact, with a torque of 2 Nm. Mounting pins Tighten the counter nut (18 A/F) with a torque of 40 Nm ± 4 Nm in holding the screw to avoid it rotating. Disc Fig. 4 Screws for airgap adjustment WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 4/7
5 Checking airgap area, see Fig. 6. Checking airgap area Microswitch connection : According to versions, the brake is supplied either with a male connector, or with free wires of 1500 mm length (see chapter 5.3). Normally closed (Connector version) Normally closed or normally opened, with the choice. (free wires version) Black Red "NC" Blue "NO" 4.3 Brake exchange All works on the electrical connections have to be made with power off. Fig Adjusting the microswitch Slide a wedge 0,10 mm thick close to the screw between the face of the magnet and the moving armature. Switch on the current and tighten the adjusting screw H M5 (8/flat) in contact with the microswitch until you reach the commutation point. Check that it functions correctly by a few successive draws and releases (see Fig. 7). Fit again a 0,10 mm thick gauge and check if the adjustment is stable. Fit a 0,15 mm thick gauge and check that the microswitch is not actuated. During maintenance, make sure that the mechanism to be braked by the brake, is stopped and that there is no risk of it accidentally starting up. All intervention have to be made by qualified personnel, owning this manual. Disconnect the electrical connection, of the brake. Remove the brake. Clean the friction surfaces with a clean dry doth. These brakes are designed to work in dry conditions. Any contact with oil, grease, water or abrasive dust causes a decrease in torque. Detection screw Nut Airgap Detection screw, stroke measure Microswitch Pin: 6 max. see Mount the new brake, following the instructions in chapter 3.3. Warning: after replacement, it is necessary to make a dynamic braking test, in order to validate the installation. Fig. 7 Operation microswitch Current range 10 ma min. to 100 ma max. at 24 VDC Maximum electrical lifetime of the microswitch ensure only by switching under resistive load. WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 5/7
6 5 Electrical connection Microswitch Brake ERS VAR11-01 operates on a direct current supply. Polarity does not affect the way the brake operates. Coil 5.1 Important recommendations All works on the electrical connections have to be made with power off. Make sure that the nominal supply voltage is always maintained. A lack of power results in a reduction to the maximum airgap. Emergency braking : for emergency braking the switching OFF must be connected on DC current side, in order to obtain short engaging time of the brake. Service braking : for service braking, the switching OFF and the switching ON must be connected on AC current side, in order to obtain silent switching. The connecting wires must be thick enough to help prevent sudden drops in voltage between the source and the brake. Length of cable 0 to 10 m from 10 to 20 m Cross section 1,5 mm 2 2,5 mm 2 Tolerances on the supply voltage at the brake terminals +5% / -10% (NF C ). 5.2 Grounding To be compliant with VDE 580, the customer must ground the brake (see Fig. 1). Grounding screw and safety washer supplied. Fig. 8 The brake version with free wires is supplied with conduit box where it is possible to connect a protective sheath. When connecting the conduits on the conduit box ( Fig. 9), the customer must avoid any restraint, able to prevent the self-floating of the brake. Conduit box 5.3 Connector / free wires According to versions, the brake is supplied either with a male connector (Fig.8), which is linked to the coil and the microswitch, or with free wires of 1500 mm length (Fig. 9). Male connection supplied with the brake AMP male connector ref : AMP contact ref Female connection (not supplied) : AMP female connector ref : AMP contact ref (indicative) Fig. 9 Protective sheath connection WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 6/7
7 6 Spare parts Part Friction pads Microswitch Thank you to join to your request for spare part, the reference and the part number of the brake, (see example below). Nominal voltage Power Date of the manufacture Reference Tangential force /---- Part number of the brake Batch of production Serial number 95/16/EC certification by the TÜV SÜD Industrie Service 7 Tools Tools Function Feeler gauge Airgap & microswitch adjustment Open jawed spanner 18 mm A/F Airgap adjustment Torque wrench (measurement range > 50 Nm) with open ended spanner attachement 18 mm A/F Airgap adjustment Open jawed spanner 8 mm A/F Microswitch adjustment Multimeter Voltage checking 8 Troubleshooting and fault elimination Fault Cause Troubleshooting Remedy Brake does not release Brake does not engage Nuisance braking Supply voltage too low Power supply is interrupted Airgap too large Worn friction pads Coil is damaged Airgap too small Overexcitation time too short Voltage present at switch off position Grease on friction faces Hand release lever actuated Holding voltage too low State of microswitch incorrect Check and adjust supply voltage Reconnect power supply, check the adjustment of microswitch Re-adjust the airgap (chapter 4.1) Replace pads Replace the brake Re-adjust the airgap (chapter 4.1) Increase overexcitation time Check the microswitch s adjustment and the customer s power supply Clean the disc and replace the brake Release the lever Check and adjust the holding voltage Re-adjust the microswitch Subject to alteration without prior notice WARNER ELECTRIC EUROPE - Rue Champfleur, B.P , F St Barthélemy d Anjou Cedex SM429gb - rev 06/11 7/7
Electrically Released Brakes ERS VAR10 SZ 5000/5000
SM366gb - rev 01/06 S E R V I C E Electrically Released Brakes ERS VAR10 SZ 5000/5000 M A N U A L EC type certificate ABV 604/1 according drawing 1 12 106602 WARNER ELECTRIC EUROPE Rue Champfleur, B.P.
More informationElectromagnetic single disc clutches E210 and E220
SM307gb - rev 11/04 S E R V I C E Electromagnetic single disc clutches E210 and E220 M A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41
More informationGEARLESS Z4 - Z20 A.C.
3761 en - 2016.09 / e This manual is to be given to the end user GEARLESS Z4 - Z20 A.C. drive for lift Installation and maintenance manual LEROY-SOMER Installation and maintenance manual GEARLESS Z4 -
More informationPneumatic Single Disc and Dual Disc Brakes P250 and P620
P-208-WE SM318-gb-02/09 Pneumatic Single Disc and Dual Disc Brakes P20 and P20 Service Manual We, WARNER ELECTRIC EUROPE,, rue Champfleur, B.P. 2009, F-49182 St Barthélemy d Anjou Cedex declare that the
More informationHydraulic Multi-Disc Brake H420 P-2067-WE SM320gb - rev 02/09
Hydraulic Multi-Disc Brake H420 P-2067-WE SMgb - rev 02/09 Service Manual We, WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélemy d Anjou Cedex declare that the brakes made in
More informationElectromagnetic Toothed Clutch E330
P-2041-WE SM310-gb-11/04 Electromagnetic Toothed Clutch E330 Service Manual We: WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélemy d Anjou Cedex declare that the clutches made
More informationHydraulic Multidisc Clutch H 110 VAR00 P-2066-WE SM301gb - rev 02/09
Hydraulic Multidisc Clutch H 1 VAR00 P-2066-WE SM301gb - rev 02/09 Service Manual We, WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélémy d Anjou Cedex, declare that the clutches
More informationInstallation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes
Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the clutch and damage may be caused by not observing it Table of contents: Page1: - Table of contents
More informationInstallation and Operating Instructions for ROBA-stop -silenzio Type 896._3_. Sizes
Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the clutch and damage may be caused by not observing it. Table of contents: Page 1: - Table of contents
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationInstallation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7
Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other
More informationInstallation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9
Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:
More informationWrap spring clutches & brakes CB & Super CB Series
SM592-gb - 02/08 S E R V I C E Wrap spring clutches & brakes CB & Super CB Series M A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41 21
More informationInstallation and Operational Instructions for ROBA-stop Holding Brake Type _._
Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:
More informationD58 Series Brake Instructions
D58 Series Brake Instructions 4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsbrakes.com Safety information 2 Safety information 2.1 Persons responsible for the safety
More informationType 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...
More informationSolenoid Operator 0513 / 1213
nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating
More informationSolenoid Operator 0516 / 1216
nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More informationInstallation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)
Spring-Set Disc Brakes P/N 8-078-98-06 effective /7/ Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex wrench
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationSERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016
SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or
More informationType 6213 EV, 6281 EV
Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions
More informationTina 4A Connection block
Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read
More informationDSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min
83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7
More informationInstallation and Operational Instructions for ROBA-stop -silenzio Type 896. _. Sizes
Please read these Operational Instructions carefully and follow them accordingly! Contents: Ignoring these Instructions can lead to lethal accidents, malfunctions, brake failure and damage to other parts.
More informationERD Electrically Released Brakes
ERD Electrically Released Brakes P-229 819-0453 Installation Instructions Warner Electric s ERD series spring set, electrically released brakes are designed to hold a load when the power to the brake is
More informationOperating and maintenance handbook Brake motors series CCL
Operating and maintenance handbook Brake motors series CCL Rev. 01 SAFETY BRAKE SERIES CCL Specifications of the brake series CCL The electromechanic spring brake series CCL is a direct current brake.
More informationSafety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.
27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....
More informationOperating Instructions Garlock Butterfly Valves DN : mm / 2-24
Operating Instructions Garlock Butterfly Valves DN : 50-600 mm / 2-24 PN : 10 / 16 Type: GAR-SEAL SAFETY-SEAL STERILE-SEAL MOBILE-SEAL Conformity declaration... 14 0 Introduction... 15 1 Proper use...
More informationHeat Meter Integrator
Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationINSTALLATION MANUAL FOR EVO BRAKES
INSTALLATION MANUAL FOR EVO BRAKES DATE OF CREATION: 18/03/2013 DATE OF REVIEW: 13/11/2017 REACH: EVO-01/EVO-05 REVIEW: ES13 1 / 31 ÍNDICE 1 SAFETY INSTRUCTIONS:... 3 1.1 Symbols used:... 3 1.2 General
More informationInstallation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes
Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions can lead to lethal accidents, malfunctions, brake failure and damage to other parts. These Installation
More informationProportional Solenoid for Hydraulics ATEX + IECEX
Proportional Solenoid for Hydraulics ATEX + IECEX 4 Product group Function Armature space pressure tight, rated pressure 50 bar Magnetic force vs. stroke characteristic linear in the adjustment range Large
More informationOperating Instructions Pedestrian Turnstile Type MPT 33
Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11
More informationInstallation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)
Spring-Set Disc Brakes P/N 8-078-98-0 effective 6/6/0 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex
More informationInstallation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _.
Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents: Page
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationBAH series Use and Maintenance Manual
Page 1 of 15 BAH 225-280 series Use and Maintenance Manual Page 2 of 15 We would like to thank you for trusting us and buying our product. Field of application Before starting the motor, it s necessary
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationCharacteristics of model K brake
Characteristics of model K brake The brake model K is a spring applied d.c. brake. It has been designed to stop rotational movement of machine shaft. However the user has to ensure that the brake is in
More informationROBATIC ROBA -quick ROBA -takt. Reliable coupling and braking.
Reliable coupling and braking Equipment Technology Packaging Machinery Conveyors and Materials Handling Equipment Door drives Indexing tables ROBATIC ROBA -quick ROBA -takt www.mayr.de Electromagnetic
More informationDatasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.
Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount
More informationCAUTION CM-SE CM-S21 CM-S41
CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and
More informationType MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation
Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung
More informationDC Single-Acting High Performance Solenoids
DC Single-Acting High Performance Solenoids 1 Product group G TC A Function Increasing magnetic force vs. stroke characteristic Push and pull type Construction Robust closed cylindrical design Fastening
More informationElectrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180
Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180 P-273-8-WE 819-0531 Installation Instructions Vented Enclosed Version Optional Warner Electric s MBFB series of Electrically
More informationProportional Solenoids for Hydraulics G RC Y 037, 045, 063
Proportional Solenoids for Hydraulics 4 Product group G RC Y 037, 045, 063 According to DIN VDE 0580 Armature space pressure tight Nominal operating pressure (dynamic) Magnetic force vs stroke graph horizontal
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15
17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationInstallation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)
Spring-Set Disc Brakes P/N 8-078-98-0 effective 03/6/4 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex
More informationInstallation and Operational Instructions for ROBA-stop -M Brake Type 891. _. _ Sizes 2 500
Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. These Installation
More informationInstallation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11
Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the brake and any damage may be caused by not observing it. Table of contents: Page 1: Page 2: Page 3:
More informationPilot control unit with end position lock for the remote control of directional valves
Pilot control unit with end position lock for the remote control of directional valves RE 64 553/02.07 1/12 Replaces : 05.05 Type 4THF6 or 5THF6 Series 2X Contents Functional description, section, symbol
More information2-port seat valves PN16 with flanged connection
4 330 Acvatix 2-port seat valves PN16 with flanged connection VVF40.. Grey cast iron EN-GJL-250 valve body DN 15...150 k vs 1.9...315 m 3 /h Can be equipped with SAX..-electromotoric or SKD..-, SKB..-
More informationInstallation and Operating Instructions Electric Vibrators HV/VFL Series
Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084
More informationSOLENOID VALVES AND PNEUMATIC VALVES
A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly
More informationCOMBIBOX. Program Schedule. Design. COMBIBOX clutch-brake-combination type 10 / 09 / 06. Attachments
clutch-brake-combination 10 / 09 / 06 with an energised to engage single sided clutch / brake... 10 with an energised to engage single sided clutch without brake... 09 with an energised to engage single
More informationDSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min
83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)
More informationPlease read these Operational Instructions carefully and follow them accordingly!
Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. These Installation
More informationFocus on Sci. & Tech. Grasp Details
Focus on Sci. & Tech. Grasp Details B Series Safety brake, adopts modular design and has multiple functions, which can facilitate super rapid response with its professionally designed for low power electromagnetic
More informationElectromagnetic Clutch and Brake Combinations Series EM/EMER/EP
A L T R A I N D U S T R I A L M O T I O N Electromagnetic Clutch and Brake Combinations Series EM/EMER/EP Contents Sizing & Selection... page Clutch / Brake Combinations EM / EMER VAR 01... page 6 EM /
More informationTina 10A/B/C Adaptor unit
Original instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationEPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19
, IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex
More informationMGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5
MGV25.X USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5 Ver. 3.7 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11
More informationCO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080
CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are
More informationDatasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.
Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow
More informationCharacteristics of model T-Mec brake
Characteristics of model T-Mec brake These traditional AC brakes, besides their tested reliability, have the following characteristics: Very strong structure; Quick operating times. They can be considered
More informationOn/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet
SPECIALISTS IN ELECTROMAGNETIC SOLENOIDS DEVICESAND SOLUTIONS On/Off- Solenoid to RL 94/9/EG (ATEX 95) 4 Product Group G HP E Pamphlet To DIN VDE 0580 and RL 94/9/EG (ATEX 95) Pressure-tight armature space,
More informationInstallation, Service and Parts List Series 56,800 for Class I & II, Division 2 Manual Adjust Brakes
Spring-Set Disc Brakes P/N 8-078-905-8 effective /0/0 Installation, Service and Parts List Series 56,800 for Class I & II, Division Manual Adjust Brakes Tools required for installation and servicing: /8
More informationULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2
AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationOPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L
OPERATION & MAINTENANCE MANUAL 3005/ /12 en Ed. 01 1.2012 SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L CONTENTS 1. SAFETY RULES 1.1. General safety instructions 1.2. Safety precautions 1.3. Intended use
More informationTina 11A Connection block
Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationINSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator
INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator Serial #: Date Installed: Your Dealer: READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE. SAVE THESE INSTRUCTIONS. Introduction
More information! CAUTION! Damages on the machine possible.
1 DATAFLEX is a maintenance free torque measurement shaft with integrated speed measurement. In connection with the RADEX -N steel disc coupling it is a torsionally stiff double cardanic coupling with
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More information70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing
Bulletin No. BK4772S-3 (6/2017) 70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing Read carefully before attempting to assemble, install, operate or maintain the product described.
More informationSAFETY PRODUCTS. ASK-Series Safety Mat Product Manual
SAFETY PRODUCTS ASK-Series Safety Mat Product Manual 2TLC010047M0201_D ORIGINAL INSTRUCTIONS Read and understand this document Please read and understand this document before using the products. Please
More informationSpring-applied single-disc brake. Operating Instructions A00 CLASSIC LINE
CLASSIC LINE Operating Instructions 77 600..A00 Spring-applied single-disc brake Types: 77 60010A00 77 60011A00 77 60013A00 77 60016A00 77 60019A00 77 60024A00 Contents 1. General information... 3 1.1
More informationT1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK
T1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK SERIAL NUMBER NOTIFICATION The information contained in this document is subject to change without prior notice. Navico UK Ltd. shall not be liable for
More informationGIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.
GIB SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) TECHNICAL DATA ENTRY LEVEL tilt sensor with MEMS technology. Space-saving solution, high performances, easy installation. High IP protection level, resistance
More informationStromag Dessau. safety in motion PRODUCT CATALOGUE. NFF4F-LS Brake. for Slow-Running High Torque Drivelines, in harsh environment
Stromag Dessau safety in motion PRODUCT CATALOGUE NFF4F-LS Brake for Slow-Running High Torque Drivelines, in harsh environment ENGINEERING THAT MOVES THE WORLD Applications Holding brake variations with
More informationHydraulic Caliper Disc Brakes SFRA 5
BRAKE SYSTEMS FOR WIND ENERGY Rotor Brake (active) Hydraulic Caliper Disc Brakes SFRA 5 25 PINTSCH BUBENZER is certified according to DIN EN ISO 9001:2000 SFRA 5 (µ = 0,4) SFRA 5 (µ = 0,3) SFRA 5 (µ =
More informationEngineering data sheet
Chapter: Actuators Page: of Sheet No.: Ci ISB Solenoid Actuator Ci ISB Solenoid actuator Item numbers covered by his datasheet 00 Ci ISB Solenoid only 0 Ci ISB Solenoid & Manual General The Solenoid actuator
More informationAngle seat valve with diaphragm actuator VZXA-...-M
Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationFMC-1/2 Tina Muting unit
Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationMG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6
MG300 USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6 Ver. 3.2 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39
More informationType 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation
Type 5411, 5413 3/2 or 4/2 way solenoid valve 3/2 oder 4/2-Wege-Magnetventil Électrovanne 3/2 ou 4/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 THE OPERATING INSTRUCTIONS The
More informationInstallation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0
Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:
More informationHoneywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION
Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.
More informationHANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1
HANDBOOK Ed. 2017 1 CHAPTER 9 ACTUATORS APPLICATIONS The actuators in series 9700, 9720, and 9730 can be assembled using suitable flanged connections, to be purchased separately, to Castel 2-way valves
More informationAngle seat valve with piston actuator VZXA-...-K
Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com
More informationSERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016
SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016 3010/16 en Ed.10.2016 Read these Operating Instructions before performing any transportation, installation, commissioning,
More informationElectromagnetic single-face clutch. Operating Instructions E00 ACTIVE CLUTCH LINE
ACTIVE CLUTCH LINE Operating Instructions 86 011..E00 Electromagnetic single-face clutch Types: 86 01103E00 86 01104E00 86 01106E00 86 01107E00 86 01109E00 86 01111E00 86 01114E00 86 01117E00 86 01121E00
More information