CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.
|
|
- Bernice Lindsey
- 5 years ago
- Views:
Transcription
1 CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS
2 POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall This ultra-compact 63 A busbar system can be installed quickly, easily and safely... offering flexible access to standard, clean earth, dual and three The compact flexible choice phase power circuits. 134
3 POWER TRACK 1 2 Easy connections with complete safety... Push the connectors together, slide the cover over and create a safe, secure coupling which can only be released by inserting a screwdriver into the locking point 3 4 With a track height of 17 mm and an overall height of just mm (including tap-offs), even the smallest of floor voids can be serviced 17mm mm With multiple tap-off points, floor boxes can be supplied pre-wired in numerous configurations to meet individual requirements 135
4 standard Two bar and earth 63amp Power Track system. Standard Feeder Unit, Track Lengths and Standard Feeder Unit Standard Track Lengths SFU 1.2 metres, 4 Tap-Offs STL metres, 6 Tap-Offs STL metres, 8 Tap-Offs STL metres, 10 Tap-Offs STL metres, 12 Tap-Offs STL36 SEC Standard Feeder Unit Joining Track Lengths Arena-Walsall Standard Track Length When assembled all sliders must be pushed fully home to ensure earth continuity. Standard Feeder Unit 125 Standard Track Length 2-20/25mm knock-out entries. Terminal Capacity 16mm 2 max. Supplied complete with terminal block, lid and turnbuckle fastener. Terminal Block Connection Track Housing Manufactured from pre-galvanized sheet steel to BS4678 part Track Conductor (x2) Manufactured from high conductivity copper. Track Insulator Manufactured from extruded PVC. Sockets / Plug / Slider Shutters Manufactured from mineral filled nylon. Feed Pins Simply push-fit end cap on to unused ends of track lengths
5 standard Standard Tap-Offs Standard Flexible Bend & Mark 1 Adaptor Standard Tee Units & Four Way Standard Tap-offs Standard Flexible Bend Standard Tee Unit 3 Metres, Unfused STO3U 3 Metres, Fused STO3F 5 Metres, Fused STO5F All Tap-offs comply with Section 7 of BS7671: 2001 (Blue Book). For compliance to Section 7 of BS7671: 1992 (Yellow Book) see page 145. Mark 1 to Standard Adaptor SFB1 SMA Left feed Centre feed Right feed Standard Four Way STU/A STU/B STU/C SFW Standard Flexible Bend Standard Tee Unit (Centre Feed) Standard tap-offs are denoted by a silver label with a black border. These tap-offs can also be used with the Dual Circuit Power Track. Mark 1 to Standard Adaptor Standard Four Way 43 Cable Length - 3 or 5 metres Unfused tap-offs are rated at 32amp. Fused tap-offs are supplied with a standard BS amp fuse. Tap-off length refers to the cable and not the conduit length. The conduit is 200mm shorter than the cable length. Standard Flexible Bend 1 metre Comprises a length of 25mm conduit with a plug-in feed at each end, pre-wired with 10mm 2 tri-rated cable. Cable length = 1 metre Other lengths are available to order. Can be used as a bend or an offset. Mark 1 to Standard Adaptor STU/A Left feed. STU/B Centre feed. Plug Pins (x2) Earth / Fuse Clips Manufactured from phosphor bronze. Cable 4mm 2 LSF. Conduit Manufactured from galvanized steel and comes complete with a 20mm gland. 1 metre Used for joining an existing run of Mark 1 Track Length to updated run of Standard Track Length. Mark 1 Track Length STU/C Right feed. Tees and Four Ways are supplied complete with slider. 137
6 clean earth Three bar and earth 63amp Power Track system with additional fully floating clean earth bar. Clean Earth Feeder Unit, Track Lengths and Clean Earth Feeder Unit Clean Earth Track Lengths CFU 1.2 metres, 4 Tap-Offs CTL metres, 6 Tap-Offs CTL metres, 8 Tap-Offs CTL metres, 10 Tap-Offs CTL metres, 12 Tap-Offs CTL36 SEC Clean Earth Feeder Unit Joining Track Lengths Arena-Walsall Clean Earth Track Length When assembled all sliders must be pushed fully home to ensure earth continuity. Clean Earth Feeder Unit 125 Clean Earth Track Length /25mm knock-out entries. Terminal Capacity 16mm 2 max. Supplied complete with terminal block, lid and turnbuckle fastener. Terminal Block Connection 75 Track Housing Manufactured from pre-galvanized sheet steel to BS4678 part Track Conductor (x3) Manufactured from high conductivity copper. Track Insulator Manufactured from extruded PVC. Sockets / Plug / Slider Shutters Manufactured from mineral filled nylon. Feed Pins Simply push-fit end cap on to unused ends of track lengths
7 clean earth Clean Earth Tap-Offs Clean Earth Flexible Bend & Mark 1 Adaptor Clean Earth Tee Units & Four Way Clean Earth Tap-offs Clean Earth Flexible Bend Clean Earth Tee Unit 3 Metres, Unfused CTO3U 3 Metres, Fused CTO3F 5 Metres, Fused CTO5F All Tap-offs comply with Section 7 of BS7671: 2001 (Blue Book). For compliance to Section 7 of BS7671: 1992 (Yellow Book) see page 145. CFB1 Mark 1 to Clean Earth Adaptor CMA Left feed Centre feed Right feed Clean Earth Four Way CTU/A CTU/B CTU/C CFW Clean Earth Flexible Bend Clean Earth Tee Unit (Centre Feed) Clean Earth tap-offs are denoted by a silver label with a red border. These tap-offs can also be used with the Dual Circuit Power Track. Mark 1 to Clean Earth Adaptor Clean Earth Four Way 43 Cable Length - 3 or 5 metres Unfused tap-offs are rated at 32amp. Fused tap-offs are supplied with a standard BS amp fuse. Tap-off length refers to the cable and not the conduit length. The conduit is 200mm shorter than the cable length. Clean Earth Flexible Bend 1 metre Comprises a length of 25mm conduit with a plug-in feed at each end, pre-wired with 10mm 2 tri-rated cable. Cable length = 1 metre Other lengths are available to order. Can be used as a bend or an offset. Mark 1 to Clean Earth Adaptor CTU/A Left feed. CTU/B Centre feed. Plug Pins (x3) Earth / Fuse Clips Manufactured from phosphor bronze. Cable 4mm 2 LSF. Conduit Manufactured from galvanized steel and comes complete with a 20mm gland. 1 metre Used for joining an existing run of Mark 1 Track Length to updated run of Clean Earth Track Length. Mark 1 Track Length CTU/C Right feed. Tees and Four Ways are supplied complete with slider. 139
8 dual circuit Five bar and earth 63amp Power Track system incorporating both standard and clean earth systems within one enclosure. Dual Circuit Feeder Unit, Track Lengths and Dual Circuit Feeder Unit Dual Circuit Track Lengths DFU 1.2 metres, 4 Tap-Offs DTL metres, 6 Tap-Offs DTL metres, 8 Tap-Offs DTL metres, 10 Tap-Offs DTL metres, 12 Tap-Offs DTL36 SEC Dual Circuit Feeder Unit Joining Track Lengths Arena-Walsall Dual Circuit Track Length When assembled all sliders must be pushed fully home to ensure earth continuity. Dual Circuit Feeder Unit 125 Dual Circuit Track Length /25mm knock-out entries. Terminal Capacity 16mm 2 max. Supplied complete with terminal block, lid and turnbuckle fastener. Terminal Block Connection 75 Track Housing Manufactured from pre-galvanized sheet steel to BS4678 part Track Conductor (x5) Manufactured from high conductivity copper. Track Insulator Manufactured from extruded PVC. Sockets / Plug / Slider Shutters Manufactured from mineral filled nylon. Feed Pins Simply push-fit end cap on to unused ends of track lengths
9 dual circuit Dual Circuit Tap-Offs Dual Circuit Flexible Bend Dual Circuit Tee Units & Four Way Dual Circuit Tap-Off Dual Circuit Flexible Bend Dual Circuit Tee Unit 3 Metres, Unfused DTO3U 3 Metres, Fused DTO3F 5 Metres, Fused DTO5F DFB1 Left feed Centre feed Right feed DTU/A DTU/B DTU/C All Tap-offs comply with Section 7 of BS7671: 2001 (Blue Book). Dual Circuit Four Way For compliance to Section 7 of BS7671: 1992 (Yellow Book) see page 145. DFW Standard and Clean Earth tap-offs may also be used with Dual Circuit Power Track, see pages and 139. Dual Circuit Flexible Bend Dual Circuit Tee Unit (Centre Feed) Dual Circuit tap-offs are denoted by a silver label with a black and red border. These tap-offs can only be used with the Dual Circuit Power Track. Dual Circuit Four Way 43 Cable Length - 3 or 5 metres Unfused tap-offs are rated at 32amp. Fused tap-offs are supplied with a standard BS amp fuse. Tap-off length refers to the cable and not the conduit length. The conduit is 200mm shorter than the cable length. Dual Circuit Flexible Bend 1 metre Comprises a length of 25mm conduit with a plug-in feed at each end, pre-wired with 10mm 2 tri-rated cable. Cable length = 1 metre Other lengths are available to order. Can be used as a bend or an offset. DTU/A Left feed. DTU/B Centre feed. Plug Pins (x5) Earth / Fuse Clips Manufactured from phosphor bronze. Cable 4mm 2 LSF. Conduit Manufactured from galvanized steel and comes complete with a 20mm gland. DTU/C Right feed. Tees and Four Ways are supplied complete with slider. 141
10 three phase Four bar and earth 63amp Power Track system. Three phased bars, one neutral bar and earth. Three Phase Feeder Unit, Track Lengths and Three Phase Feeder Unit Three Phase Track Lengths PFU 1.2 metres, 4 Tap-Offs PTL metres, 6 Tap-Offs PTL metres, 8 Tap-Offs PTL metres, 10 Tap-Offs PTL metres, 12 Tap-Offs PTL36 SEC Three Phase Feeder Unit Joining Track Lengths Arena-Walsall Three Phase Track Length When assembled all sliders must be pushed fully home to ensure earth continuity. Three Phase Feeder Unit 125 Three Phase Track Length /25mm knock-out entries. Terminal Capacity 16mm 2 max. Supplied complete with terminal block, lid and turnbuckle fastener. Terminal Block Connection Track Housing Manufactured from pre-galvanized sheet steel to BS4678 part Track Conductor (x4) Manufactured from high conductivity copper. Track Insulator Manufactured from extruded PVC. Sockets / Plug / Slider Shutters Manufactured from mineral filled nylon. Feed Pins 63 Simply push-fit end cap on to unused ends of track lengths
11 three phase Three Phase Tap-Offs Three Phase Flexible Bend Three Phase Tee Units & Four Way Three Phase Tap-offs Three Phase Flexible Bend Three Phase Tee Unit 3 Metres, Unfused Reconfigurable PTO3UR PFB1 Left feed 3 Metres, Fused Reconfigurable PTO3FR Centre feed 3 Metres, Unfused (L1, L2 & L3 connected) PTO3U Right feed 5 Metres, Fused Reconfigurable PTO5FR Three Phase Four Way PTU/A PTU/B PTU/C PFW Three Phase Flexible Bend Three Phase Tee Unit (Centre Feed) 3 Phase tap-offs are denoted by a white label with a blue border. These tap-offs must only be used with the 3 Phase Power Track. Three Phase Four Way 43 Cable Length - 3 or 5 metres Unfused tap-offs are rated at 32amp. Fused tap-offs are supplied with a standard BS amp fuse. Tap-off length refers to the cable and not the conduit length. The conduit is 200mm shorter than the cable length. Three Phase Flexible Bend 1 metre Comprises a length of 25mm conduit with a plug-in feed at each end, pre-wired with 10mm 2 tri-rated cable. Cable length = 1 metre Other lengths are available to order. Can be used as a bend or an offset. PTU/A Left feed. PTU/B Centre feed. Plug Pins (x4) Earth / Fuse Clips Manufactured from phosphor bronze. Cable 4mm 2 LSF. Conduit Manufactured from galvanized steel and comes complete with a 20mm gland. PTU/C Right feed. Tees and Four Ways are supplied complete with slider. 143
12 clamp and hanger brackets Hold Down Clamp Vertical Hanger Bracket Horizontal Hanger Bracket Hold Down Clamp SHC Vertical Hanger Bracket SVB Horizontal Hanger Bracket SHB Arena-Walsall C Use suitable screws to fasten hold down clamp to floor through two 6mm diameter holes. Simply clip track length into hold down clamp (no additional fastenings required). Recommended spacing between hold down clamps is 2 metres with at least one clamp per length. Supplied in two parts complete with clamping screws A. Use one M8 threaded rod B and four M8 nuts C (one above and below each bracket flange). Recommended spacing between vertical hanger brackets is 1 metre maximum. A B A C Supplied in two parts. Use two M8 threaded rods A and four M8 nuts B (one above and below each bracket flange). Recommended spacing between horizontal hanger brackets is 1 metre maximum. A B A B Threaded Rods page 93 Threaded Rods page
13 technical information Certification Asta Certified and tested to BS EN 439-1:1999 and BS EN 439-2:2000. Manufactured within a BSI/ASTA approved BS EN ISO facility. IEE Wiring regulations Legrand fully complies with regulations of BS7671:2001 (IEE Wiring regulations - Blue Book). Section 7 Requirements Tap-Offs All items within this Product Guide comply with the relevant paragraphs of Section 7 of BS7671:2001 (IEE Wiring regulations - Blue Book). If compliance to Section 7 of BS7671:1992 (Yellow Book) is required, then this must be stated clearly at time of order, as an extra protective conductor may be required. Section of the wiring regulations require any conductor exceeding 3m in length to have a fault current protective device (e.g. Fuse) at the point where current carrying capacity is reduced (tap-off plug). All tap-offs over 3m will be supplied by Legrand with a BS amp fuse fitted within the plug. If the system is to be protected by a 32amp breaker then Unfused tap-offs exceeding 3m may be specified at time of order. 4mm 2 LSF cable is used in all fused and unfused tap-offs. System Coding The four systems are colour coded using the following format: System Label Border Background Standard Black Silver Clean Earth Red Silver Dual Circuit Black and Red Silver 3 Phase Blue White The sytem is designed such that locations of all conductors are consistant throughout the standard, Clean Earth and Dual Circuit variants. This means that tap-offs from the Standard and Clean Earth systems can be used with the Dual Circuit track to tap-off the relevant circuit. At any time along a run of Dual Circuit track the installation could be down graded, if required, to either the Standard or Clean Earth systems. 145
14 technical information Specification / Technical Data Electrical Data Arena-Walsall Rated Current Rated Voltage Frequency Rated Short Circuit Withstand Track Conductor Resistance - Line and Neutral Track Conductor Impedance Volt Drops Line and Neutral: Track Tap-Off (32amp - 4mm 2 cable) Flexible Bend (10mm 2 tri-rated cable) Feed Unit Track Connector Earth Fault Loop Impedance: L+N Track Conductors Earth Track Conductor Tap-Off (32amp - 4mm 2 cable) Feed Unit Track Connector Flexible Bend (10mm 2 tri-rated cable) Mechanical Data 63amps 250V / 415V 50/ Hz 16kA 3mΩ/m 1.5mΩ/m 3mV/A / m 10mV/A / m 3.7mV/A / m 0.3mV/A / m 0.4mV/A / m 1.5mΩ/m 1.2mΩ/m 33mΩ (3 metre L/N/E) 0.3mΩ 0.4mΩ 3.7mΩ (1 metre length L/N/E) Number of Conductors PE + 2,3,4 & 5 Track Conductor cross section area 13mm 2 Incoming Cable termination capacity 16mm 2 Tap-Off Cable 32amp Unfused 4mm 2 Tap-Off Cable 32amp Fused 4mm 2 Tap-Off Conduit 16mm / 20mm Diameter Feeder Conduit Entry 20mm / 25mm Diameter IP Rating IP40 (When fully assembled) Maximum Profile Height mm Including Tap-Off Track Height 17mm Material Specification Track Housing Track Conductors Track Insulator Sockets, Track Connectors, Track Ends Tap-Off Plugs End Shutters and Track Shutters Tap-Off / Flexible Bend Cable Tap-Off / Feeder and Connector Pins Galvanized Steel High Conductivity Copper Self Extinguishing PVC Extrusion Nylon Nylon Glass Filled Nylon LSF/PVC Brass 146
15 technical information Typical Layout 3 compartment service outlet box complete with 1 standard twin socket and 1 clean earth red twin socket. Meeting Rooms 3 compartment service outlet box complete with 2 clean earth red twin sockets. 3 compartment service outlet box complete with 2 standard twin sockets. A typical layout might consist of numerous service outlet boxes with both standard and clean earth sockets, e.g. within a call centre. Two boxes with just clean earth sockets (fax, photocopier etc.) and boxes with standard sockets in the meeting rooms. With the Arena- Walsall Power Track the boxes with both standard and clean earth sockets can be fed with a dual circuit tap-off into dual circuit track. The two clean earth boxes can be fed from the dual circuit track with just a clean earth tap-off. The system can then be downgraded by connecting standard track on to the dual circuit track by means of a flexible bend or direct connection. The continuing circuit is then restricted to a standard 2 bar and earth. This will save the contractor time and money by eliminating the need for extra feed cable, feed units and end caps that would be required with separate systems. Call Centre Plant Room 1
Arena-Walsall power track system standard
standard Standard track length SL12 Standard feeder unit SFU Standard tap-off SO3U Standard SFB 1 Dimensions and technical information (p. 198-199) wo bar and earth 63 power track system Pack Cat. Nos.
More informationelevate your flexibility
elevate your flexibility SOLUFLEX CABLE MANAGEMENT FLOOR SYSTEM / PRODUCT GUIDE Global vision... 21st Century solutions Why choose Legrand? In a word, confidence. Legrand is a world leader in its field,
More informationElectrak power track underfloor power distribution systems
4 www.electrak.co.uk Electrak power track underfloor power distribution systems Tel: 01207 503400 Fax: 01207 501799 Email: sales@electrak.co.uk Because of our policy of continuous improvement, Electrak
More informationElectrak powertrack / underfloor busbar system
design and installation n General installation notes Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm Feed units are provided with one or two 25 mm diameter
More informationUnderfloor to desk 231
Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.
More informationUnderfloor Busbar. Betatrak Underfloor Busbar. 82
Underfloor Busbar Underfloor Busbar Busbars offer an efficient, flexible solution to underfloor power distribution as they use a click fit method for that fast and simple install. To reduce up front labour
More informationadaptable, reliable underfloor power
adaptable, POWERTRACK reliable adaptable, reliable underfloor power 6 THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal
More informationBetatrak Compliance Standard
Betatrak Compliance Standard ASTA Certificate of Verification Tests Laboratory Ref. No: 45673/1 APPARATUS: Rated current 63A, rated voltage 240V/415V, rated impulse voltage 4kV, 50Hz, a range of underfloor
More informationSTERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power
Sterling Busbar is cable management made easy. It is a 63Amp single phase system for use in standard or clean earth power distribution. A safe system to use, due to an internal screw fix Busbar cover and
More informationSnake Bus Power Distribution
Snake Bus Power Distribution ELECTRICAL CHARACTERISTICS Rated Current 50 Amps Rated Voltage 208Y/120 or 480Y/277 Volts Frequency 50/60 Hz Conditional Short Circuit Rating (Protection device) 16 KA Conductor
More informationKAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System
25-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / CONTENTS E-LINE / General 2-3 System 4 Technical Characteristics 5 Standard Busbars 6 Standard Elements 7 Tap Off Plugs 8 Standard
More informationKAP A Plug-in Busbar Distribution System IEC ME 04
EAE Elektrik A.Ş. Akcaburgaz Mahallesi, 119. Sokak, No:1 341 Esenyurt-Istanbul-TURKEY Tel: +9 (212) 866 2 Fax: +9 (212) 886 24 2 www.eae.com.tr 2-32 A Lighting Busbar System Y A N D EN V E IT AL s ISO
More informationRECESSED TRACK (120V) SPECIFICATIONS
RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,
More informationFLOOR DISTRIBUTION SYSTEMS
FLOOR DISTRIBUTION SYSTEMS Time and cost effective energy distribution systems that provide a fast and flexible interface between floor services and the office environment. These systems are quick and
More informationSURFACE TRACK (120/250V) SPECIFICATIONS
SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed
More informationLB - LIGHTING BUSWAY 25-40A
16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationCABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and
More informationCellwatch Electrical Installation
Tech20081110-1-1 Cellwatch Electrical Installation Critical Distances...2 Typical Layout...3 Typical ibmu Placement...4 Typical Control Unit Placement...5 Physical Mounting and Location - General...6 CU
More informationXL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL³ 400 metal distribution cabinets, free-standing Cat. No(s) : 20103/04/05/06/07/08/18/19/23/ CONTENTS PAGE 1. General characteristics...
More informationINTEGRID TRACK (120V) SPECIFICATIONS
INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to
More informationINDEX Bustrunking System Standard & Specifications Technical Parameters Copper Aluminum Components
INDEX Bustrunking System.. (1) Standard & Specifications.. (2) Technical Parameters Copper.. (3-4) Aluminum.. (5-6) Components Straight Length (Feeder & Plug in type).. (7) Uniblock Joint, Edge Elbow &
More informationSpec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number
Spec Sheet: IEC309 Switched Socket, Horizontal 16A Part Numbers Part Number EU67HSS316 EU67HSS416 EU67HSS516 Description IEC309 16A 3 Pin switched socket IEC309 16A 4 Pin switched socket IEC309 16A 5 Pin
More informationXL Distribution enclosures WORKSHOP SPECIFICATIONS
800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged
More informationGreater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE
Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to
More informationInteract Underfloor Power
Interact Underfloor Power 77 technical hotline +44 (0)1268 563720 raised floor systems range introduction features and benefits Interact Underfloor Power is a low profile powertrack system catering for
More informationHIGH POWERBAR COPPER UL857
HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 E+I Engineering s High Powerbar (HPB) UL857 range is a 600 Volt totally encased, non-ventilated, low impedance busduct. The range is available from
More informationTWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A
TWIN FAN Installation and Wiring Instructions Models:- ITC and ITC-DS Maximum load : 220-240V 50Hz ~ 9A and 380-415V 50Hz 3 ~ 9A IMPORTANT - READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION.
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More information2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED
2 CIRCUIT TRACK SURFACE TRACK COLOR INSTALLATION PROFILE WHITE POWDER COAT SILVER ANODIZED PLASTER FLANGE RECESSED VISIBLE FLANGE RECESSED BLACK ANODIZED Page 1/9 SURFACE TRACK SYSTEM : compose your system
More informationXL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A
XL 3 -N 125 250 SimPly, EfficiEnt And SAfE 3 - PHASE distribution boards up to 250 A the global specialist in ElEctricAl And digital building infrastructures Xl 3 -n Comprehensive and reliable range for
More informationRelax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationWavePro LT Busway Cost effective solution for electrical distribution
Busway Cost effective solution for electrical distribution 1/ Busway 20 year life Mylar wrap insulation Up to 5000A for both Feeder and Plug-In IP 40/42/55/65 protections 50% AL housing ground with internal
More informationExplosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS
Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any
More informationPOWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.
BUSBAR TRUNKING SYSTEM BUSWAY A 6A Your Idea System! POWERFLOW Series Series COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD. COMPAC ELECTRIC s.r.l. No.6, Ln. 24, Sec. 2, Zhonghua S. Rd., XinWu Township,
More informationLow Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM
Low Voltage Systems MNS BS - front & rear access switchboards Tested, tried & trusted solutions Power and productivity for a better world TM MNS BS Tested, tried and trusted MNS - Global system design
More informationGAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura
Modular-C\Standardized Motor Control Centres\ M600204.15 PT Guna Era Manufaktura Catalogue 2015 GAE MCC Modular-C Standardized Motor Control Centres General Definition Type-tested low-voltage switchgear
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More information3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.
1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction
More information3 Pin Schuko Converter Plug Technical Data & Fitting Instructions
3 Pin Schuko Converter Plug Technical Data & Fitting Instructions Description The 3 Pin Schuko Converter Plug (SCP3) is an adapter that converts the European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS
Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 03-0054 CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS EPN, LPN, SPN This standard details the procedures to be undertaken
More informationOn-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)
(BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) Author: IET Publications (edited by Mark Coles) Book details Author: IET Publications (edited by Mark Coles) Year: 2011 Format: Paperback,
More informationDistribution Blocks & Bus-bar Solutions
Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided
More informationBUSBAR TRUNKING SYSTEMS a
BUSBAR TRUNKING SYSTEMS 25-63 a Contents 4-9 General features Light and Power. The solution that comes from above 4 The enhanced LB PLUS range 6 Simplified installation for increased performance 8 10-12
More informationSafety Lampholders and Pendants
Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring
More informationype UP T Busplugs Low Voltage Switchboard Equipment
Busplugs Type UP Low Voltage Switchboard Equipment Publication UP 2013 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents Descriptive
More informationDuraplug. wiring devices portable power
220 Duraplug wiring devices portable power www.mkelectric.co.uk range introduction features and benefits The Duraplug range of heavy duty products has become a virtual byword for durability, strength and
More informationCLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001
CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS
More informationCEL Isolators Helix Cut Outs
CEL Isolators Helix Cut Outs www.charlesendirect.com Isolators-CutOuts 8pp.indd 1 24/11/2010 23:03 INTRODUCTION CEL offers a comprehensive range of LSI Lockable Safety Isolators and Helix Cut Outs all
More informationAlphabet By Ledra Brands
700 Track 700 Track 700 Track is a 1 circuit, 20A rated, line voltage track system. Its lightweight, compact elegant design is easy to install saving on overall project costs. The track is a 120v 1-circuit
More information1.1 Scope Characteristics General system description 1-2
TABLE OF CONTENTS 1. INTRODUCTION 1.1 Scope 1-2 1.2 Characteristics 1-2 1.3 General system description 1-2 2. BOXES 2.1 Box overview 2-2 2.2 Box accessories 2-2 2.3 Box fittings 2-9 2.3.1 Flanges for increasing
More informationSelection and Application Guide. busway system. Cost-effective Power Distribution Compact Design
Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationCOMMANDO. Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units.
WIRING DEVICES COMMANDO RANGE INTRODUCTION Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units. The Commando range is
More informationSpec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number
Spec Sheet: IEC309 Panel Socket, Angled 16A IP67 Part Numbers Part Number EU67SA316 EU67SA416 EU67SA516 Specification Description IEC309 16A 3 Pin panel socket, angled, IP67 IEC309 16A 4 Pin panel socket,
More informationZucchini Low-Medium Power
Zucchini Low-Medium Power High Power CATALOGUE 2010 CATALOGUE 2010-2011 ZHP08C/GB Coordination table with Legrand DPX MCCBs SL, MS, SB, MR Switch-Busbar coordination table. Contingent short circuit ka
More informationAustralian Wiring Instructions:
Australian Wiring Instructions: Generator/Switch Wiring: Remove the generator controller fascia and identify wire #44 going to the circuit breaker in the external connection box, this wire is the active
More informationMEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV
CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection
More informationMR - MEDIUM RATING A
88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118
More informationSTANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011
Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV
More informationPOWERBUS 225 Busway and Plug-In Units
Busway and Plug-In Units Class 5600 CONTENTS Schneider Electric Brands Description Page Product Descriptions.................................................. 3 POWERBUS 225 Busway System.....................................
More information4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A
2 Table of contents General information... 4 Elements of the conductor rail supply line... 4 Innovative connection method... 5 Technical properties... 6 Construction of the line section... 6 Line section...
More informationGas Insulated Switchgear
Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology
More information31-SDMS-02 REV. 01 SPECIFICATIONS FOR
31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationNS Feeder pillar up to 3200A
NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,
More informationSingle foot switches - PX and PA series
Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified
More informationPipe Brackets - Pipe Support. Systems Brass Pipe brackets Brass Pipe clips
Select Language Home Profile Products Contact Us Email Resources Brass Sanitary Fittings Brass Cable Glands Cable Gland Accessories Brass Fasteners Pipe Brackets - Pipe Support Systems Brass Pipe brackets
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationCOMPACT BUSWAY 40 & 60 AMP HOUSING
40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV
MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,
More informationHX Range Catalogue. Contact. About Anord Mardix.
H Range Catalogue Contact Anord Mardix IBAR (EMEA) Ltd Castle Mills, Aynam Road Kendal, Cumbria, LA9 7DE UK Email: emea.sales@anordmardix.com Call: +44 (0) 1539 720161 www.linkedin.com/company/anordmardix
More informationScreed Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 4 2.Installation process 5 to 10 3.Products details 11 to 24 4.Technical characteristics 25 to 26 1 RANGE. Optional
More informationCENTRE FEED UNIT UP TO 4000A. Safety
CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support
More informationSwitched on street lighting
Switched on street lighting lucy fused products The Lucy fused product range features the popular Trojan street lighting isolators, the Titan range of street lighting cut outs with many classleading features,
More informationTRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Reduced-profile, single-circuit trac sections for surface or pendant mounting. Compatible with a full range of feed, connector
More informationTwo Circuit Trac System TRAC SECTION, JOINERS & FEEDS
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single
More informationAFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
More informationGas Insulated Metal-clad Switchgear, HMGS!
Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,
More informationArmoured / Un-armoured Cable Gland
Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance
More information4 Pole / 5 Pole Enclosed Conductor System
4 / 5 Pole Conductor System 4 Pole / 5 Pole Enclosed Conductor System Enclosed Conductor system with IP23 Finger proof cellular profile. Available in intensities from 20 Amp 200 Amp Data sheet ref : 10
More informationtitan Street lighting cut outs fused products
titan Street lighting cut outs fused products The Titan2 Cut out is supplied as standard with many class-leading features that make the installer s task considerably easier. Take for instance the cam lever
More informationLSI 20 Series 30A, 120V Surface Busway Components 1
LSI Busway System LSI 20 Series 30A, 120V Surface Busway Components 1 IBEW union made at LSI plant in USA Specification grade heavy duty.075 (1.8mm) extruded aluminum busway 8 foot (2.4m) and 12 foot (3.7m)
More information31-SDMS-01 REV. 03 SPECIFICATIONS FOR
31-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PANEL This specification is property of SEC and subject to change or modification without any notice CONTENTS Clauses: Page No. 1.0 SCOPE
More informationGENERAL INDEX TR60. 6 YELLOW LINE Continuous Conductors. Max 5 Poles. 8 BLUE LINE Pre-Mounted Conductors TR85H5P. YELLOW LINE Continuous Conductors
2 Automation - Lift - Handling System GENERAL INDEX 2 DESCRIPTION 3 BUSBAR LINE VERSIONS LINE TYPE / AMPERAGE COVERAGE 5 TR60 40 A 50 A 60 A 70 A 100 A 140 A 160 A 200 A 320 A 6 YELLOW LINE Continuous
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationCity & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to:
City & Guilds 2381 Test 2382 Level 3 Q1 Which one of these electrical installations does BS 7671:2008 not apply to: Temporary Construction sites Distributor s Equipment Caravans Public Premises Q2 Which
More informationICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical
ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical
More informationNPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations
Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification
More informationOn_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.
1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV
CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description
More informationNT-300 Series Single Circuit Track System & Accessories
NT-300 Series Single Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral copper conductors.
More informationCAST RESIN BAR IP68 BUSBAR SYSTEM
CAST RESIN BAR IP68 BUSBAR SYSTEM 01 www.powerbarsystems.com Powerbar HPB CAST CAST RESIN RESIN BAR CONTENTS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 Introduction Standards Busbar Dimensions
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More informationDistribution boards. 68 Q-DIN Range
Complete electric boards system for energy distribution in commercial, industrial and costrucion sites places. Available in both empty and wired version, in compliance with the IEC 61439 Standard: Versions
More information