Arena-Walsall power track system standard

Size: px
Start display at page:

Download "Arena-Walsall power track system standard"

Transcription

1 standard Standard track length SL12 Standard feeder unit SFU Standard tap-off SO3U Standard SFB 1 Dimensions and technical information (p ) wo bar and earth 63 power track system Pack Cat. Nos. rack lengths and feeder unit Standard track lengths Recommended spacing between two clamps no greater than one metre 1 SL metres, 4 tap-offs 1 SL metres, 6 tap-offs 1 SL metres, 8 tap-offs 1 SL metres, 10 tap-offs 1 SL metres, 12 tap-offs Standard feeder unit Supplied with to be 1 SFU 2 x 20/25 mm knockout entries Standard tap-offs SL12 SFU ll tap-offs conform to Section 607 of BS 7671 : 2001 hese tap-offs can also be used with the dual circuit power track Standard 1 SFB1 Comprises a length of 25 mm conduit with a plug-in feed at each end, pre-wired with 10 mm 2 tri-rated cable Standard tee units Supplied with slider and 1 SU Left feed 1 SU B Centre feed 1 SU C Right feed Standard four way 1 SFW Supplied complete with slider and two end caps ccessories 1 Spare hold down clamp SFB1 SU B SFW 1 SO3U 3 metres, unfused 1 SO3F 3 metres, fused 1 SO5F 5 metres, fused 2 Bar + Earth SO3F 1 Spare end cap Standard power track is denoted by a white label with a black flash 194

2 clean earth track length CL12 feeder unit CFU tap-off CO3U CFB 1 Dimensions and technical information (p ) hree bar and earth 63 power track system including an independant clean earth copper bar Pack Cat. Nos. rack lengths and feeder unit track lengths Recommended spacing between two clamps no greater than one metre 1 CL metres, 4 tap-offs 1 CL metres, 6 tap-offs 1 CL metres, 8 tap-offs 1 CL metres, 10 tap-offs 1 CL metres, 12 tap-offs feeder unit Supplied with to be 1 CFU 2 x 20/25 mm knockout entries tap-offs ll tap-offs conform to Section 607 of BS7671 : 2001 hese tap-offs can also be used with the dual circuit power track 1 CO3U 3 metres, unfused 1 CO3F 3 metres, fused 1 CO5F 5 metres, fused CL12 CFU Clean Earth CO3U 1 CFB1 Comprises a length of 25 mm conduit with a plug-in feed at each end, pre-wired with 10 mm 2 tri-rated cable tee units Supplied with slider and 1 CU Left feed 1 CU B Centre feed 1 CU C Right feed four way 1 CFW Supplied with slider and two end caps ccessories 1 Spare hold down clamp CFB1 CU B CFW 1 Spare end cap power track is denoted by a white label with a red flash 195

3 dual circuit track length DL12 feeder unit DFU tap-off DO3U DFB 1 Dimensions and technical information (p ) Five bar and earth 50 power track system incorporating both standard and clean earth systems within one enclosure Pack Cat. Nos. rack lengths and feeder unit track lengths Recommended spacing between two clamps no greater than one metre 1 DL metres, 4 tap-offs 1 DL metres, 6 tap-offs 1 DL metres, 8 tap-offs 1 DL metres, 10 tap-offs 1 DL metres, 12 tap-offs feeder unit Supplied with to be 1 DFU 2 x 20/25 mm knockout entries tap-offs ll tap-offs conform to Section 607 of BS 7671 : 2001 hese tap-offs must only be used with the dual circuit power track ll tap-offs from standard and clean earth track can also be used 1 DO3U 3 metres, unfused 1 DO3F 3 metres, fused 1 DO5F 5 metres, fused DL12 DFU Dual Circuit D03U 1 DFB1 Comprises a length of 25 mm conduit with a plug-in feed at each end, pre-wired with 10 mm 2 tri-rated cable tee units Supplied with slider and 1 DU Left feed 1 DU B Centre feed 1 DU C Right feed four way 1 DFW Supplied with slider and two end caps ccessories 1 Spare hold down clamp DFB1 DU B DFW 1 Spare end cap power track is denoted by a white label with a black and red flash For pre-wired floor boxes and grommets, see p. 200, 204 Contact us on

4 three phase Single phase track length PL12 Single phase feeder unit PFU Single phase tap-off PO3UR hree phase PFB 1 Dimensions and technical information (see p ) Four bar and earth 50 power track system. hree phased bars, one neutral bar and earth Pack Cat. Nos. rack lengths and feeder unit hree phase track lengths Recommended spacing between two clamps no greater than one metre 1 PL metres, 4 tap-offs 1 PL metres, 6 tap-offs 1 PL metres, 8 tap-offs 1 PL metres, 10 tap-offs 1 PL metres, 12 tap-offs hree phase feeder unit Supplied with to be 1 PFU 2 x 20/25mm knockout entries ap-offs for three phase power track Single phase tap-offs ll tap-offs conform to Section 607 of BS 7671 : 2001 BS 7671 : 2001 amendment No.2 fixed wiring hese tap-offs must only be used with the 3 phase power track 1 PO3UR 3 metres, unfused reconfigurable 1 PO3FR 3 metres, fused reconfigurable 1 PO5FR 5 metres, fused reconfigurable hree phase tap-off PL12 PFU ll tap-offs conform to Section 607 of BS7671 : 2001 his tap-off must only be used with the 3 phase power track Single Phase PO3FR hree phase 1 PFB1 Comprises a length of 25 mm conduit with a plug-in feed at each end, pre-wired with 10 mm 2 tri-rated cable hree phase tee units Supplied with slider and 1 PU Left feed 1 PU B Centre feed 1 PU C Right feed hree phase four way 1 PFW Supplied with slider and two end caps ccessories 1 Spare hold down clamp 1 Spare end cap SFB1 PU B SFW 1 PO3U 3 metres, unfused (L1, L2 and L3 connected) Single Phase PO3U hree phase power track is denoted by a white label with a blue flash For pre-wired floor boxes and grommets, see p. 200, 204 Contact us on

5 technical information Specification / technical data erminal block connections Electrical data Rated current Rated voltage Frequency Rated short circuit withstand rack conductor resistance - line and neutral rack conductor impedance Volt drops Line and neutral : track ap-off (32-4 mm 2 cable) Flexible bend (10 mm 2 tri-rated cable) Feed unit rack connector Earth fault loop Impedance : L+N track conductors Earth track conductor ap-off (32-4 mm 2 cable) Feed unit rack connector Flexible bend (10 mm 2 tri-rated cable) 63 / V/415 V 50/60 Hz 16 k 3 mω/m 1 43 mω/m 2 86 mv//m 10 mv//m 3 7 mv//m 0 3 mv//m 0 4 mv//m 1 5 mω/m 1 2 mω/m 33 mω (3 metre L/N/E) 0 3 mω 0 4 mω 3 7 mω (1 metre L/N/E) L3 Standard L2 hree phase N L N L N L1 he three phase system is not interchangeable N2 L2 N1 L1 he three types above are compatible and an installation can be downrated from the dual circuit to either standard or clean earth in mid-run by means of a or direct connection (see opposite) rack length ll dimensions in mm Mechanical data Number of conductors PE + 2,3,4 and 5 rack conductor cross section area 13 mm 2 Incoming cable termination capacity 16 mm 2 ap-off cable 32 unfused 4 mm 2 ap-off cable 13 fused L/N : 2 5 mm 2, E : 4 mm 2 ap-off conduit 16 mm/20 mm diameter Feeder conduit entry 20 mm/25 mm diameter IP rating IP 40 (when fully assembled) Maximum profile height 47 mm including tap-off rack height 17 mm Material specification rack housing rack conductors rack insulator Sockets, track connectors, track ends ap-off plugs End shutters and track shutters ap-off / cable ap-off / feeder and connector pins echnical information Galvanised steel High conductivity copper Self extinguishing PVC extrusion Nylon Nylon Glass filled nylon LSF/PVC Brass Certification sta Certified and tested to BS EN : 1999 and BS EN : 2000 Manufactured within a S BEB approved ISO 9001:2000 facility Feeder units ap-offs Overall height : 47 mm with feeder unit and tap-off wo 20/25 mm knockout entries Supplied complete with terminal block, lid and turnbuckle fastener and ll dimensions in mm 60 Section of the Wiring Regulations require any conductor exceeding 3 m in length to have a fault current protective device (e.g. fuse) at the point where current carrying capacity is reduced (tap-off plug) ll tap-offs over 3 m will be supplied with a BS fuse fitted within the plug If the system is to be protected by a 32 breaker then unfused tap-offs exceeding 3 m may be specified at time of order Other pre-wired tap-off lengths are available on request Unfused tap-offs are rated at 32 Fused tap-offs are supplied with a standard BS fuse mm IEE Wiring regulations Legrand fully complies with BS 7671 : 2001 Section 607 requirements ll items comply with the relevant paragraphs of Section 607 of BS 7671 : 2001 Cable length - 3 or 5 m ap-off length refers to the cable and not the conduit length he conduit is 250 mm shorter than the cable length 198

6 ap-offs for three phase power track Single phase tap-offs hree phase tap-off ypical Layout he example opposite shows a typical layout consisting of numerous service outlet boxes with both standard and clean earth sockets in the call centre, two boxes with just clean earth sockets (fax, photocopier, etc) and boxes with standard sockets in the meeting rooms. Boxes with both standard and clean earth sockets can be fed with a dual circuit tap-off into a dual circuit track. he two clean earth boxes can be fed from the dual circuit track with just a clean earth tap-off PO3FR / PO5FR (fused) PO3UR (unfused) PO3U (unfused) he system can then be downgraded by connecting standard track on to the dual circuit track by means of a or direct connection. he continuing circuit is then restricted to a standard two bar and earth. his will save the contractor time and money by eliminating the need for extra cable and feeder units that would be required with separate systems ees and four ways Supplied complete with slider, lid, turnbuckle fasteners and end cap(s) Four way ee unit Left feed tee unit Component Cat. No./ Centre feed tee unit Component Cat. No./B Right feed tee unit Component Cat. No./C rack length (1 800 mm) rack length (1 200 mm) Flexible bends 1 metre Flexible bend End cap Cat. No. 19 Feeder unit ll dimensions in mm Meeting rooms Hold down clamp 80 Black Each power track length is supplied already fitted with sliding clamps. 2 clamps on each 1 2, 1 8 and 2 4 metre length 3 clamps on each 3 0 and 3 6 metre length Call centre R Red ll dimensions in mm 128 Vertical hanger bracket C Supplied in two parts complete with clamping screws () Use one M8 threaded rod (B) and four M8 nuts (C) (one above and below each bracket flange) Recommended spacing between vertical hanger brackets is 1 metre maximum B C R Red / Black Plant room Horizontal hanger bracket Supplied in two parts Use two M8 threaded rods () and four M8 nuts (B) (one above and below each bracket flange) Recommended spacing between horizontal hanger brackets is 1 metre maximum B B 3 compartment service outlet box complete with 1 standard twin socket and 1 clean earth red twin socket. 3 compartment service outlet box complete with 2 clean earth red twin sockets. 3 compartment service outlet box complete with 2 standard twin sockets. 199

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS. CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS www.legrand.co.uk POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall

More information

elevate your flexibility

elevate your flexibility elevate your flexibility SOLUFLEX CABLE MANAGEMENT FLOOR SYSTEM / PRODUCT GUIDE Global vision... 21st Century solutions Why choose Legrand? In a word, confidence. Legrand is a world leader in its field,

More information

Electrak powertrack / underfloor busbar system

Electrak powertrack / underfloor busbar system design and installation n General installation notes Electrak powertrack is a compact system that can be installed in floor voids as low as 48 mm Feed units are provided with one or two 25 mm diameter

More information

Electrak power track underfloor power distribution systems

Electrak power track underfloor power distribution systems 4 www.electrak.co.uk Electrak power track underfloor power distribution systems Tel: 01207 503400 Fax: 01207 501799 Email: sales@electrak.co.uk Because of our policy of continuous improvement, Electrak

More information

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

adaptable, reliable underfloor power

adaptable, reliable underfloor power adaptable, POWERTRACK reliable adaptable, reliable underfloor power 6 THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak powertrack / underfloor busbar is perfect for cavity floor installations. With minimal

More information

Underfloor Busbar. Betatrak Underfloor Busbar. 82

Underfloor Busbar. Betatrak Underfloor Busbar. 82 Underfloor Busbar Underfloor Busbar Busbars offer an efficient, flexible solution to underfloor power distribution as they use a click fit method for that fast and simple install. To reduce up front labour

More information

Betatrak Compliance Standard

Betatrak Compliance Standard Betatrak Compliance Standard ASTA Certificate of Verification Tests Laboratory Ref. No: 45673/1 APPARATUS: Rated current 63A, rated voltage 240V/415V, rated impulse voltage 4kV, 50Hz, a range of underfloor

More information

STERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power

STERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power Sterling Busbar is cable management made easy. It is a 63Amp single phase system for use in standard or clean earth power distribution. A safe system to use, due to an internal screw fix Busbar cover and

More information

FLOOR DISTRIBUTION SYSTEMS

FLOOR DISTRIBUTION SYSTEMS FLOOR DISTRIBUTION SYSTEMS Time and cost effective energy distribution systems that provide a fast and flexible interface between floor services and the office environment. These systems are quick and

More information

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System 25-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / CONTENTS E-LINE / General 2-3 System 4 Technical Characteristics 5 Standard Busbars 6 Standard Elements 7 Tap Off Plugs 8 Standard

More information

Cellwatch Electrical Installation

Cellwatch Electrical Installation Tech20081110-1-1 Cellwatch Electrical Installation Critical Distances...2 Typical Layout...3 Typical ibmu Placement...4 Typical Control Unit Placement...5 Physical Mounting and Location - General...6 CU

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Snake Bus Power Distribution

Snake Bus Power Distribution Snake Bus Power Distribution ELECTRICAL CHARACTERISTICS Rated Current 50 Amps Rated Voltage 208Y/120 or 480Y/277 Volts Frequency 50/60 Hz Conditional Short Circuit Rating (Protection device) 16 KA Conductor

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A TWIN FAN Installation and Wiring Instructions Models:- ITC and ITC-DS Maximum load : 220-240V 50Hz ~ 9A and 380-415V 50Hz 3 ~ 9A IMPORTANT - READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION.

More information

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) Author: IET Publications (edited by Mark Coles) Book details Author: IET Publications (edited by Mark Coles) Year: 2011 Format: Paperback,

More information

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number Spec Sheet: IEC309 Switched Socket, Horizontal 16A Part Numbers Part Number EU67HSS316 EU67HSS416 EU67HSS516 Description IEC309 16A 3 Pin switched socket IEC309 16A 4 Pin switched socket IEC309 16A 5 Pin

More information

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

KAP A Plug-in Busbar Distribution System IEC ME 04

KAP A Plug-in Busbar Distribution System IEC ME 04 EAE Elektrik A.Ş. Akcaburgaz Mahallesi, 119. Sokak, No:1 341 Esenyurt-Istanbul-TURKEY Tel: +9 (212) 866 2 Fax: +9 (212) 886 24 2 www.eae.com.tr 2-32 A Lighting Busbar System Y A N D EN V E IT AL s ISO

More information

cavity floor service outlet boxes

cavity floor service outlet boxes Reversible lid 2 cable outlets with sponge foam to prevent ingress Rapid fit /remove mechanism adjusts for flooring thickness Durabable ABS trim and lid surround Full range of power and data module plates

More information

Switched on street lighting

Switched on street lighting Switched on street lighting lucy fused products The Lucy fused product range features the popular Trojan street lighting isolators, the Titan range of street lighting cut outs with many classleading features,

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification

More information

Floor boxes... choice, flexibility and easy installation

Floor boxes... choice, flexibility and easy installation Floor boxes... choice, flexibility and easy installation 2, 3 and 4 compartment raised access loor boxes and slab boxes offer complete versatility. Floor boxes are available pre-wired with power track

More information

Interact Underfloor Power

Interact Underfloor Power Interact Underfloor Power 77 technical hotline +44 (0)1268 563720 raised floor systems range introduction features and benefits Interact Underfloor Power is a low profile powertrack system catering for

More information

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL³ 400 metal distribution cabinets, free-standing Cat. No(s) : 20103/04/05/06/07/08/18/19/23/ CONTENTS PAGE 1. General characteristics...

More information

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001 CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS

More information

INDEX Bustrunking System Standard & Specifications Technical Parameters Copper Aluminum Components

INDEX Bustrunking System Standard & Specifications Technical Parameters Copper Aluminum Components INDEX Bustrunking System.. (1) Standard & Specifications.. (2) Technical Parameters Copper.. (3-4) Aluminum.. (5-6) Components Straight Length (Feeder & Plug in type).. (7) Uniblock Joint, Edge Elbow &

More information

Safety Lampholders and Pendants

Safety Lampholders and Pendants Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring

More information

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010 Candidate Code No. Result Date Int For Board Use Only ER38 Version of AS/NZS 3000 used (tick ONE Box) 2000 2007 & Amend 1 ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010 QUESTION AND ANSWER BOOKLET

More information

ANZI Transfer Switch and Generator Wiring Installation Addendum

ANZI Transfer Switch and Generator Wiring Installation Addendum ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE

More information

titan Street lighting cut outs fused products

titan Street lighting cut outs fused products titan Street lighting cut outs fused products The Titan2 Cut out is supplied as standard with many class-leading features that make the installer s task considerably easier. Take for instance the cam lever

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show. 1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Australian Wiring Instructions:

Australian Wiring Instructions: Australian Wiring Instructions: Generator/Switch Wiring: Remove the generator controller fascia and identify wire #44 going to the circuit breaker in the external connection box, this wire is the active

More information

COMMANDO. Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units.

COMMANDO. Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units. WIRING DEVICES COMMANDO RANGE INTRODUCTION Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units. The Commando range is

More information

Installing a Downstream Distribution Panelboard

Installing a Downstream Distribution Panelboard Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to

More information

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD. BUSBAR TRUNKING SYSTEM BUSWAY A 6A Your Idea System! POWERFLOW Series Series COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD. COMPAC ELECTRIC s.r.l. No.6, Ln. 24, Sec. 2, Zhonghua S. Rd., XinWu Township,

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

My Reserve 500 Install Guide

My Reserve 500 Install Guide My Reserve 500 Install Guide System Overview Diagram Warnings Disclaimer of Liability and Warranty: This guide does not replace the Owner s Guide and Installation Instructions supplied with the components.

More information

HIGH POWERBAR COPPER UL857

HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 E+I Engineering s High Powerbar (HPB) UL857 range is a 600 Volt totally encased, non-ventilated, low impedance busduct. The range is available from

More information

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011 Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV

More information

Duraplug. wiring devices portable power

Duraplug.  wiring devices portable power 220 Duraplug wiring devices portable power www.mkelectric.co.uk range introduction features and benefits The Duraplug range of heavy duty products has become a virtual byword for durability, strength and

More information

Screed Floor system LIMOGES Cedex. Phone : Fax :

Screed Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 4 2.Installation process 5 to 10 3.Products details 11 to 24 4.Technical characteristics 25 to 26 1 RANGE. Optional

More information

Plexo 3 weatherproof cabinets

Plexo 3 weatherproof cabinets 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Plexo 3 weatherproof cabinets CONTENTS PAGES 1. Description, use.....1 2. Range, equivalence table...1 3. Overall dimensions...2

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 36 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES 2 ALINOX INSULATED CONDUCTOR RAIL Features, advantages and benefit The insulated conductor rail system ALINOX is the most suitable solution

More information

Guidelines How To Wire DRH Modules

Guidelines How To Wire DRH Modules Guidelines How To Wire DRH Modules NOTE: This document mainly provides guidance on wiring in relation to mains (domestic electricity supply) switching applications for this module. The guidelines are based

More information

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET ER47 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Int Time Allowed: Three

More information

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting The Electrical Contractors Association SELECT MEMBERSHIP NUMBER 15019 ELECTRICAL INSTALLATION CERTIFICATE (REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - BS 7671 [IET WIRING REGULATIONS]) EI Copyright The

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number Spec Sheet: IEC309 Panel Socket, Angled 16A IP67 Part Numbers Part Number EU67SA316 EU67SA416 EU67SA516 Specification Description IEC309 16A 3 Pin panel socket, angled, IP67 IEC309 16A 4 Pin panel socket,

More information

Swifts cable ladder ancillary items

Swifts cable ladder ancillary items earth continuity connector If a supplementary bonding conductor for equipotential earthing is required, straight lengths and fittings in all Swifts ladder ranges have fixing holes provided to accommodate

More information

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED 2 CIRCUIT TRACK SURFACE TRACK COLOR INSTALLATION PROFILE WHITE POWDER COAT SILVER ANODIZED PLASTER FLANGE RECESSED VISIBLE FLANGE RECESSED BLACK ANODIZED Page 1/9 SURFACE TRACK SYSTEM : compose your system

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

EASIGO Series INDUSTRIAL PLUGS AND SOCKETS TO BS REFERENCE STANDARDS BS 196: Industrial Plugs & Sockets BS196 FITTINGS (5-30 AMPERES)

EASIGO Series INDUSTRIAL PLUGS AND SOCKETS TO BS REFERENCE STANDARDS BS 196: Industrial Plugs & Sockets BS196 FITTINGS (5-30 AMPERES) ESIGO Series INDUSTRIL PLUGS ND TO BS9-9 REFERENCE STNDRDS BS 9: 9 Industrial Plugs & Sockets BS9 FITTINGS (5-0 MPERES) In90, BS9 was issued as the first British Standard covering industrial plugs and

More information

ENYSTAR Load Centers up to 250 A

ENYSTAR Load Centers up to 250 A PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

BUSBAR TRUNKING SYSTEMS a

BUSBAR TRUNKING SYSTEMS a BUSBAR TRUNKING SYSTEMS 25-63 a Contents 4-9 General features Light and Power. The solution that comes from above 4 The enhanced LB PLUS range 6 Simplified installation for increased performance 8 10-12

More information

WavePro LT Busway Cost effective solution for electrical distribution

WavePro LT Busway Cost effective solution for electrical distribution Busway Cost effective solution for electrical distribution 1/ Busway 20 year life Mylar wrap insulation Up to 5000A for both Feeder and Plug-In IP 40/42/55/65 protections 50% AL housing ground with internal

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

RECESSED TRACK (120V) SPECIFICATIONS

RECESSED TRACK (120V) SPECIFICATIONS RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,

More information

Commando Safetyswitch

Commando Safetyswitch 80 Commando Safetyswitch Commando Safetyswitches are manufactured from Polybutylene Terephthalate (PBT) for maximum impact resistance. The range offers a selection of IP54 and IP65 ratings to cover a variety

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM Low Voltage Systems MNS BS - front & rear access switchboards Tested, tried & trusted solutions Power and productivity for a better world TM MNS BS Tested, tried and trusted MNS - Global system design

More information

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

section-page Table 1. Transfer switching device ratings. Conditional short circuit current Operator s Manual 7000 Series ATS Automatic Transfer Switching Equipment D design 30 through 200 amperes TABLE OF CONTENTS section-page INSTALLATION... 1-1 Enclosures and Mounting... 1-1 Power Connections...

More information

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET ER52 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in

More information

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University Safety Office Reviewed: 17 July 2012 Reviewed: DD Month University Code of Practice for Electrical Safety PART B - Design and Construction of Electrical Equipment within the University The purpose of this

More information

PDI PowerWave 2 Bus System

PDI PowerWave 2 Bus System 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening, low voltage, vertical or horizontal power busway distribution system. System

More information

Spacial SF for Prisma Plus P system

Spacial SF for Prisma Plus P system The Spacial SF range includes specific enclosure models for installing the Prisma Plus P : functional units and vertical and horizontal busbars The panels are subject to type tests according to standard

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines. 1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main

More information

PART 10 ELECTRICAL INSTALLATIONS

PART 10 ELECTRICAL INSTALLATIONS PART 10 ELECTRICAL INSTALLATIONS SECTION SUBJECT 10.1 General 10.2 Cables 10.3 DC systems 10.4 Batteries 10.5 AC systems 10.6 Earthing and bonding 10.7 Motor control 10.8 Lighting 10.9 Remote stops 10.10

More information

Electrical Awareness and Considerations

Electrical Awareness and Considerations Electrical Awareness and Considerations By David Taylor FIHE MIET IEng Objectives Awareness of specifications. Awareness of Distribution Network Operators (DNO) earthing arrangements. Awareness of basic

More information

Pioneer 321 MSR. 2/14 Antwerpsesteenweg Gent - Oostakker T +32 (0) F +32 (0)

Pioneer 321 MSR. 2/14 Antwerpsesteenweg Gent - Oostakker   T +32 (0) F +32 (0) GB Instruction manual 2/14 www.welda.be F +32 (0)9 355 92 01 0 1 INTRODUCTION... 4 2 FRONT PANEL... 4 3 REAR PANEL... 5 4 INSTALLATION... 6 4.1 UNIT ASSEMBLY... 6 4.2 CONNECTIONS TO THE ELECTRICAL MAINS

More information

ype UP T Busplugs Low Voltage Switchboard Equipment

ype UP T Busplugs Low Voltage Switchboard Equipment Busplugs Type UP Low Voltage Switchboard Equipment Publication UP 2013 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents Descriptive

More information

PVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes

PVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes PVC-LINK High Impact, Complete Flexibility Product Catalogue Cable Management System Distribution Enclosure & Weatherproof oxes PVC-LINK High Impact,Complete Flexibility COMPLINCE TO STNDRD PVC-LINK is

More information

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. TENDER SCHEDULE -1-1 2 3 4 5 6 7 1 208 Point Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

workshop specifications Plexo³ IP 65 cabinets

workshop specifications Plexo³ IP 65 cabinets workshop specifications Plexo³ IP 65 THE GLOBL SPECILIST IN ELECTRICL ND DIGITL BUILDING INFRSTRUCTURES With their IP 65 weatherproof protection and optimised dimensions, Plexo³, from 2 to 4 x 18 modules,

More information

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Contents 4 MODE range: introduction 5 MODE

More information

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET ER54 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

CENTRE FEED UNIT UP TO 4000A. Safety

CENTRE FEED UNIT UP TO 4000A. Safety CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

CAST RESIN BAR IP68 BUSBAR SYSTEM

CAST RESIN BAR IP68 BUSBAR SYSTEM CAST RESIN BAR IP68 BUSBAR SYSTEM 01 www.powerbarsystems.com Powerbar HPB CAST CAST RESIN RESIN BAR CONTENTS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 Introduction Standards Busbar Dimensions

More information

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

Floor outlet boxes British Standard

Floor outlet boxes British Standard Mita floor boxes British Standard Product catalogue 2009 P117622 Mita floor boxes > + High capacity Quick-Fix function Pre-wired options Provision for RCD protection All plastic parts are halogen-free

More information

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2

More information

General characteristics

General characteristics Multipole Industrial Connectors General characteristics The multipole connectors for industrial purposes are used in electric and electronic machinery, robots, electric panels, control equipments and wherever

More information

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 03-0054 CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS EPN, LPN, SPN This standard details the procedures to be undertaken

More information