3 Pin Schuko Converter Plug Technical Data & Fitting Instructions
|
|
- Magdalene McCarthy
- 6 years ago
- Views:
Transcription
1 3 Pin Schuko Converter Plug Technical Data & Fitting Instructions Description The 3 Pin Schuko Converter Plug (SCP3) is an adapter that converts the European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug to the BS l363 system format. The plug is designed and manufactured to meet the requirements of BS It complies fully with the LVD and Plug and Socket safety regulations. The design of the clamping method ensures the body of the European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug is enclosed. Classification - Adapter, Single portable, - Re-wireable plug, - Fused, - Normal use, - Converts European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug to the BS l363 format. - Suitable for Class 1 and 2 devices (earthed and unearthed). - Not Suitable for any other plug system. Certification - BSi Kitemark to BS 5733 Relevant Standards - BS 5733 Electrical Accessories BS 1363 Plug Features BS 1362 Fuse link Rating - Voltage 240V ac - Current 13 amps max, - Load 3000 watts max. - Frequency 50 Hz - Environmental Protection IP 3X (STD BS1363 accessory rating). - Fuse 13 amp BS Flammability V2 (external Casing) - Mechanical Strength mm - Colour Black or White - Weight 60 grams typical - Finish Plain and fine sparkle - Retaining Screw Plain or Tamperproof Note: - Tolerance as per relevant British Standard Safety Design Features - Double mechanical interlocks to prevent the SCP3 from being inserted into the socket outlet without the cover and retaining screws being properly secured. - Hinged cover - External fuse access, opening of SCP3 not required - No loose parts - Plug features designed to meet the requirements of BS Meets the requirements of the DTI Plug and Socket regulations. 1 of 10
2 Installation System The 3 Pin Schuko Converter Plug (SCP3) is designed for use within the BS1363 Plug and Socket system only, as defined by the IEE Wiring Regulations BS 7671 Fitting The 3 Pin Schuko Converter Plug (SCP3) should be fitted as follows (see full details below): 1. Open SCP3 2. Insert the Schuko Plug into the SCP3. 3. Close lid 1 4. Tighten retaining screws 2 to 0.4N.m (4.08Kgf.cm). 5. Assembly complete NOTE 1: - If the cover does not close fully, this may mean that the Schuko Plug has not been correctly fitted, check, and rectify before use. NOTE 2: - This torque setting is for hand screwdrivers, if required, please contact us for guidance regarding power screwdriver settings Service Conditions - Temperature Range - Storage -40 o C to +80 o C Ambient - Working -05 o C to +35 o C 95% RH Ambient - Altitude 2000m above sea level max. - Not subject to exposure to direct radiation from the sun - Abnormal Condition - Avoid pollution by smoke, chemical and flammable fumes salt laden spray, periods of high humidity > 95% relative humidity (RH) 2 of 10
3 SCP3 FITTING INSTRUCTIONS Straight Schuko A B Diagram 1 Product received closed Insert thumbs at A and B and pull open lid. Product now ready to use, see diagram 2 3 of 10
4 Diagram 2 Get plug and install in to clips, and close lid aligning clips, see diagram 3. 4 of 10
5 C D Diagram 3 Close lid Ensure clips C and D align and click home, see diagram 4. 5 of 10
6 E Diagram 4 Lid now secured by clips, and ready to screw up as shown, tighten screws to a torque of 0.4 Nm (Maximum) Fitting complete 6 of 10
7 SCP3 FITTING INSTRUCTIONS Right Angle Schuko A B Diagram 1 Product received closed Insert thumbs at A and B and pull open lid. Product now ready to use, see diagram 2 7 of 10
8 Diagram 2 Get plug and install in to clips, and close lid aligning clips, see diagram 3. 8 of 10
9 C D Diagram 3 Close lid Ensure clips C and D align and click home, see diagram 4. 9 of 10
10 E Diagram 4 Lid now secured by clips, and ready to screw closed (2 screws E ) as shown, tighten screws to a torque of 0.4 Nm (Maximum) Fitting complete 10 of 10
Underfloor to desk 231
Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.
More informationi RANGE HYDROPATH Technology The home of
i RANGE HYDROPATH Technology The home of Input Voltage 87-240V AC Input Frequency 47-63 Hz Material Specifications Main unit: Anodised Aluminium End plates: UL V-0 rated polycarbonate Water and Dust Protection
More informationTechnical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...
More informationSolenoid coil Types BB, BE, BF, BG, and BN
Data sheet Solenoid coil Types BB, BE, BF, BG, and BN The coils are specially designed to operate in the aggressive environment of high humidity and temperature fluctuations that you find in most refrigeration
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationTechnical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications ETS12-01-04 Specification ETS12-01-04 Ver 3 Contents 1. Purpose and Scope...
More informationPAT120, PAT150 and PAT150R
PAT120, PAT150 and PAT150R Simple tick or cross, pass or fail indication plus measurement Battery powered with rechargeable options Safe 250 V insulation and leakage test for surge-protected and IT equipment
More informationT2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc
GE Power Conversion MVR1600-4601: 690V, 1600Adc FEATURES/SPECIFICATIONS Rated at 690 Vac, 1600 Adc (nominal). Thyristor/Diode based Rectifier Bridge Module. Air Cooled. Protected Pre-charge circuit. RELATED
More informationRail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals
Ecolec 300 The Ecolec 300 series is a rail mounted, compact, Class 1 electricity meter, available as a single or three phase meter showing the consumption of the installation. The compact rail mounted
More informationSolenoid coil for control in potentially explosive areas Type BZ
Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used
More informationRopox Shower & Changing Bed
Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,
More informationAMTRON Xtra (E/R), Trend E, Premium (E/R)
The MENNEKES AMTRON Wallbox is a charging station for use in private and semi-public areas, such as private land, company car parks and depots. Charging acc. Mode 3 (IEC 61851) Vehicle connectors and charging
More informationTechnical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)
Ergon Energy Corporation Limited Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear ETS12-01-03 Specification ETS12-01-03 Ver 3 Contents 1. Purpose and Scope...
More informationHigh Performance Thermal Circuit Breaker
High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation
More informationDimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,
Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully
More informationChapter. Installation and. In this Chapter...
Chapter Installation and 2 Wiring In this Chapter... Ambient Conditions...2 2 Installation Considerations...2 2 Mounting Instructions...2 3 Controller and Panel Cutout Dimensions...2 4 Safety Information...2
More informationTWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A
TWIN FAN Installation and Wiring Instructions Models:- ITC and ITC-DS Maximum load : 220-240V 50Hz ~ 9A and 380-415V 50Hz 3 ~ 9A IMPORTANT - READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION.
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationMCset kv Medium voltage equipment
Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide
More information18 Watt LED Spotlight with Magnetic Base - Articulating Light Head Tilting - IP65-25' Cord w/ Plug
18 Watt LED Spotlight with Magnetic Base - Articulating Light Head Tilting - IP65-25' Cord w/ Plug Part #: MLBLT-18W-LED-25 Page: 1 The MLBLT-18W-LED-25 from Larson Electronics offers high purity optics,
More information1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings
1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the
More informationDZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection
DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage
More informationEmergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply
EM readyapply BASIC W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and battery
More information1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings
1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationLED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord
LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord Part #: WAL-DL-LED-12 Page: 1 Made in the USA The WAL-DL-LED-12 from Larson Electronics is a LED Drop Light / Work Light
More informationInstruction Manual. Vortex Mixers
Instruction Manual Vortex Mixers TABLE OF CONTENTS Package Contents............... 1 Warranty............... 1 Installation............... 2 Maintenance & Servicing............... 2 Environmental Conditions...............
More informationSPECIFICATION FOR. MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons)
SPECIFICATION FOR MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons) INDEX MAINTENANCE REPORTS MANUFACTURER S REQUIREMENTS PERMIT TO WORK CERTIFICATION GUIDANCE MINOR REPAIRS Platform
More informationOPERATOR S MANUAL Please read all the information in this booklet before using the unit.
TECHNE UCAL400 + Calibrator OPERATOR S MANUAL Please read all the information in this booklet before using the unit. Unit Serial number: 4/02 Issue 1 TECHNE is a registered Trademark of Techne Incorporated.
More informationTechnical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear ETS12-01-02 Specification ETS12-01-02 Ver 3 Contents 1. Purpose
More informationStandard Interlock Safety Switches
Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening
More informationDistribution boards. 68 Q-DIN Range
Complete electric boards system for energy distribution in commercial, industrial and costrucion sites places. Available in both empty and wired version, in compliance with the IEC 61439 Standard: Versions
More informationMAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.
INSULATION TESTER EARTH MAX. AC 600V LINE AC -+ HOLD V k M LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 CAT.III 600V INSTRUCTION
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationRUZ- _/_ Protection (3) Isolation Option (4)
Features Unregulated Converters Description Dual output from a single input rail 1kVDC or 2kVDC input/output basic isolation 1kVDC output/output isolation Power sharing on outputs Optional continuous short
More informationOpen Chassis Star-Delta Starter User Guide
Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...
More information6491B / H07Z-R / BS EN Cable
6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More informationMetrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.
Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk
More informationSTERLING BUSBAR. Sterling Busbar is cable management made easy. It is a 63Amp. single phase system for use in standard or clean earth power
Sterling Busbar is cable management made easy. It is a 63Amp single phase system for use in standard or clean earth power distribution. A safe system to use, due to an internal screw fix Busbar cover and
More information1200W INVERTER GENERATOR
1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use
More informationUnderfloor Busbar. Betatrak Underfloor Busbar. 82
Underfloor Busbar Underfloor Busbar Busbars offer an efficient, flexible solution to underfloor power distribution as they use a click fit method for that fast and simple install. To reduce up front labour
More informationnual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual
nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual Copyright Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission
More informationPlug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30
CONTROL DEVICE REFERENCE STANDARDS UNSWITCH SOCKET OUTLETS EN 60669-1 Switches for household and similar fixed-electrical installation. Part 1: general requirements. Rated current: 10A-13A-15A-16A Rated
More informationElectrak power track underfloor power distribution systems
4 www.electrak.co.uk Electrak power track underfloor power distribution systems Tel: 01207 503400 Fax: 01207 501799 Email: sales@electrak.co.uk Because of our policy of continuous improvement, Electrak
More informationINDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
More informationData sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX
PCB terminal with proven clamping yoke connection at 5.00 and 5.08 mm pitch. Conductor outlet direction 90, 135 and 180. Suitable for conductor cross-sections up to 2.5 mm². 0.13-2.50 mm² (IEC) / 26-14
More informationActionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership
Actionpac LNS4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly
More informationTECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY.
TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY. 1.0 SCOPE: This specification covers the design, manufacturing and testing of LT Distribution
More informationSpec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number
Spec Sheet: IEC309 Switched Socket, Horizontal 16A Part Numbers Part Number EU67HSS316 EU67HSS416 EU67HSS516 Description IEC309 16A 3 Pin switched socket IEC309 16A 4 Pin switched socket IEC309 16A 5 Pin
More informationDRAFT COPY, NOT FOR DISTRIBUTION
GENERAL INFORMATION This manual contains relevant information concerning the technical aspects of using the Mediheat MH900/12 Portable Fluid Bag Warmer, and should be read by all persons expected to operate
More informationTGK Prefabricated Substation Technical Data
TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary
More informationALLDATA Online Toyota Truck Tacoma 4WD V6-4.0L (1GR-FE) - Service and... Service and Repair 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Page 1 of 9 Service and Repair FRONT WIPER MOTOR REMOVAL 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 2. REMOVE FRONT WIPER ARM HEAD CAP a. Using a screwdriver wrapped with protective tape, remove
More informationSpec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number
Spec Sheet: IEC309 Panel Socket, Angled 16A IP67 Part Numbers Part Number EU67SA316 EU67SA416 EU67SA516 Specification Description IEC309 16A 3 Pin panel socket, angled, IP67 IEC309 16A 4 Pin panel socket,
More informationGE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work
GE Consumer & Industrial Power Protection New SecoGear 12-24kV GE imagination at work General SecoGear metal-clad switchgear is designed and manufactured with advance technology and has been comprehensively
More informationCABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.
CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS www.legrand.co.uk POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall
More informationUsers Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery
MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine
More informationPY, SPY; FSQC, FP; EPC; AP
Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names
More informationSolid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations
Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage
More information1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems
Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationmulticond Power capacitors Data sheet: multicond
Power capacitors multicond Monitoring Optimizing Recording multicond are one-phase and three-phase power capacitors for reactive current compensation, developed for networks with many harmonics. Apart
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationOPERATING INSTRUCTION
11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER
More informationOPERATIONS MANUAL. Mini Centrifuge Model MCF Certified
OPERATIONS MANUAL Mini Centrifuge Model MCF-2360 Certified Contents 1. Safety 2 2. Introduction 7 3. Package Contents 7 4. Specifications 8 5. Features 8 6. Parts of the Mini Centrifuge 9 7. Installation
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationCLIMATE. Climate and temperature chambers.
Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate
More informationMustang V-6 Cold Air Intake P/N: ( A600) Application: Ford Mustang 3.7L Manual or Automatic Transmission
2015-2017 Mustang V-6 Cold Air Intake P/N: 421828 (131537-9A600) Application: 2015-2017 Ford Mustang 3.7L Manual or Automatic Transmission Installation Instructions Before installing your ROUSH Performance
More informationINTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS
INTER PLANT STANDARD STEEL INDUSTRY SOFT STARTER FOR VOLTAGE UP TO 690 V AC IPSS: 1-10-040-15 IPSS NO CORRESPONDING IS 0. FOREWORD 0.1 This interplant standard has been prepared by the Standard Committee
More informationLexium integrated drives
Description ILp for CANopen, PROFIBUS DP, RS ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and a brushless DC motor.
More informationELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationProportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB
Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar
More informationGeneral safety and installation information.
Read these instructions before connecting and using your PowerBright Pure Sine Power Inverters. Failure in observing this warning may result in injury to persons and damage to equipment. General safety
More informationCORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT
TECHNOLOGIES ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT Enjoy the peace of mind ESS-ESD PRODUCT CATALOGUE CORE VALUES PEACE OF MIND EFFICIENCY FAIRNESS RESPONSIBILITY CUSTOMER ORIENTATION GROWING DEVELOPED
More informationQF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)
QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Dual Mount 1 pole Dual Mount 2 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent
More informationEASY CHARGE Waterproof portable Battery Charger
EASY CHARGE Waterproof portable Battery Charger 1.1 AND 4.3 AMP MODELS EN NL, DE, FR, ES, IT USER S MANUAL WWW.MASTERVOLT.COM/EASYCHARGE-PORTABLE 10000009117/04 2 EN / EasyCharge 1.1 and 4.3 Amp - User
More informationNPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations
Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification
More information: B3; B5; B14; B34; B35; V1
ATT WE series (Eff1) are 3-phase TEFC Cast-Iron high efficiency general purpose induction motors, which are designed to meet or exceed the requirements for energy efficiency such as: European Eff1, Australia
More information1329I Integrated Drive/Motor CE Filter Option Kit
Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the
More informationSeries 80 Mighty Mouse Technical Reference Complete Product Specification
Summary Performance Specifications Current Rating (Maximum): Size #23 Contact: 5 A., Size #20 contact: 7.5 A., Size #16 contact: 13 A., Size #12 contact: 23 A. Test Voltage (Dielectric Withstanding Voltage)
More informationCentral Battery Systems Loadstar AC/DC Systems
The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape
More informationOPERATING INSTRUCTION
11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail
More informationSystem 3 ZB1PS Device Chassis. Operator s Manual
System 3 ZB1PS Device Chassis Operator s Manual System 3 ZB1PS Operator's Manual Copyright 2007 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or transmitted
More informationBT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet
BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet Go to www.fluke.com to register your product, download manuals, and find more information. A Warning identifies conditions and procedures that are
More information500 Watt Portable LED Work Area Light Cart ft cord - 60,000 Lumens V AC
500 Watt Portable LED Work Area Light Cart - 100 ft cord - 60,000 Lumens - 120-277V AC Part #: WAL-WBC-500LTL-LED-100 Page: 1 Made in the USA The WAL-WBC-500LTL-LED-100 Cart Mounted LED Work Area Light
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationEmpty enclosures IEC 62208
374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series
More informationINSTALLATION AND USER INSTRUCTIONS
INSTALLATION AND USER INSTRUCTIONS Industrial Applications HydroFLOW i Range 45i, 60i, 100i, 120i, 160i Hydropath Holdings Ltd Hydropath House, Unit 7, The Midway Nottingham, NG7 2TS, UK Tel: +44 (0) 115
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationActuators for Fire and Smoke Protection Dampers
OpenAir TM Actuators for Fire and Smoke Protection Dampers GRA126.1E/... GRA326.1E/... Electric motor driven actuators for 2-position control, nominal torque 4 Nm, with spring return to failsafe position,
More information100 Watt Hand Lamp - Inline Transformer - Vapor Proof - VAC to VDC - 100' Foot SOOW Cord
100 Watt Hand Lamp - Inline Transformer - Vapor Proof - VAC to VDC - 100' Foot SOOW Cord Part #: VPL-120X12-100 Page: 1 Marine grade construction, an industrial 100 cord, and a stainless steel hook ensure
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationAI352 ATEX INLINE CONNECTOR TERMINATION PROCEDURE (Rev 6 02May07)
IMPORTANT NOTE Hawke International does not recommend the use of their ControlEx Connectors in applications where rigid PVC / SWA / PVC power cabling (typically to BS 6346 standards) is used in portable
More informationEnclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models
Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with
More information