T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
|
|
- Justina Perkins
- 5 years ago
- Views:
Transcription
1 Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in = 20/240Vac GF = pole HH = 22kIC QP = 2 Plug-In 2 = 240V GFCI = 65kIC QB = Bolt-on Omit for THQP GF = 2-pole breakers GFCI (all 20/240Vac) F = FCI Recommendations based on standard conditions. Installation must conform to all local and national codes. pplication Selection Recommended Circuit Breaker ppliance verage Watts Volts mps Wire Size 2-inch -inch ir Conditioner Up to,000 BTU #2 THQP20 THQL20 Up to 23,000 BTU #2 THQP220 THQL220 Up to 30,000 BTU #0 THQP230 THQL230 ttic Fan Up to 2 HP #4 THQP5 THQL5 Up to HP #2 THQP20 THQL20 Bathroom or Outdoor Receptacles #4 THQL5GF #2 THQL20GF Bedroom Receptacles (for maximum #4 THQL5F safety; required by 2002 NEC) #2 THQL20F Branch Circuits (Indoor Receptacles) #4 THQP5 THQL #2 THQP20 THQL20 Clothes ryer #0 THQP230 THQL230 ishwasher #2 THQP20 THQL20 oorbell Transformer #4 THQP5 THQL5 Electric Heater #2 THQP20 THQL20 Electric Range #6 THQP250 THQL250 Electric Welder (240V; over 0 away) #6 THQP250 THQL250 Fixed Lighting #4 THQP5 THQL5 Garbage isposal #4 THQP20 THQL20 Hot Tub or Spa #8 THQL240GF #8 THQL250GF Hot Water Heater #0 THQP230 THQL230 Motors (Single Phase) Up to 2 HP #4 THQP5 THQL5 2 to HP #2 THQP20 THQL20 to 2 HP #4 THQP25 THQL25 2 to 3 HP #0 THQP230 THQL230 Refrigerator or Freezer #4 THQP5 THQL5 Sump Pump Up to 2 HP #4 THQP5 THQL5 2 to HP #2 THQP20 THQL20 [ RELIBILITY N ECONOMY. ] Q Line Circuit Breakers 5 Washing Machine #4 THQP5 THQL5 Well Pump Up to 2 HP #2 THQP20 THQL #4 THQP25 THQL25 2 to HP #0 THQP30 THQL #2 THQP220 THQL #8 THQP240 THQL240 Special Safety Circuit Protection Products Included among GE s circuit protection products are several that add the extra measure of safety that is increasingly important to today s new home buyers and remodelers. See page 8 for details. Safety Need Safety Solution mp Rating Ground fault protection for circuits supplying power to outdoor, bathroom, kitchen, garage and spa area receptacles. GFCIs (ground fault circuit interrupters) 5-50 Maximum protection against fires through detection and interruption of arcing caused by damaged wire insulation or extension cords. The 2002 NEC FCIs (arc fault will require this protection in bedroom circuits. circuit interrupters) 5-20 Whole house protection of sensitive electronic equipment computers, fax machines, televisions, stereos, VCRs from electrical surges. Surge arrester N
2 H I G H E R Q U L I T Y. L O W E R I N S T L L E C O S T. H I G H E R Q U L I T Y. L O W E R I N S T L L E C O S T [ HIGHER QULITY. LOWER INSTLLE COST.] PowerMark Gold Load Centers 0 Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site. complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. Main lug load centers offer an economical solution for subpanels and similar applications. ll main lug units 25 and above convert easily to main breaker. GE s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kIC ratings, and all the accessories needed to complete the job. ll PowerMark Gold load centers are designed and built for faster installation and more dependable performance. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 00% neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/robertson screws speed wiring. ll holes are rated for 4-4 wire. 00% rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE s exclusive 2 THQPs. The PowerMark Gold line includes a wide range of outdoor as well as indoor units. ccessories & Options oor lock & handle ground kits Sub-feed & feedthru lugs Front filler plates Handle lock & ties Hardware kits Main breaker retainers Neutral kits Universal raintight hubs
3 Catalog Number System For illustrative purposes only. Load Center Selection Guide Main Breaker Load Centers Max. Branch Maximum Spaces Main mp Breaker Rating (mps) Rating THQL 2 THQP Total -pole Base Cu l -pole 2-pole -pole 2-pole Spaces Cat. No. Cat. No. Suffix 2 Suffix TM860 F,S CUGEN TM20 C,R CU TM200 C,R CU TM320 C CU TM242 C,R CU TM22 C,R CU TM62 C CU TM85 R CUFL TM245 C,R CU TM325 C,R CU TM65 C,R CU TM820 R CUFL TM620 C CU TM2020 C,R CU TM3220 C,R CU TM4020 C,R CU Convertible Load Centers Max. Branch Main mp Breaker Rating (mps) Maximum Spaces Cat. No. Rating THQL 2 THQP Total -pole Base Cu l -pole 2-pole -pole 2-pole Spaces Cat. No. Suffix 2 Suffix TLM62 S,F CU, TLM82 S,F CU, TLM242 C,R CU TLM22 C,R CU TLM62 C CU TLM205 C CU TLM245 C,R CU TLM620 C,R CU TLM2020 C,R CU TLM3220 C CU TLM4020 C,R CU Main Lug Load Centers Max. Branch Main mp Breaker Rating (mps) Maximum Spaces Cat. No. Rating THQL 2 THQP Total -pole Base Cu l -pole 2-pole -pole 2-pole Spaces Cat. No. Suffix 2 Suffix TL240 C,R CU TL270 C,R CU T M C CU B GE Identification Type Maximum Number Insert for 3-phase, Bus mpere Rating Enclosure Type Insert for Insert for Specials of Spaces 4-wire Load Centers PowerMark Gold M = Main Breaker = 00 C = Combination Flush CU = Copper Bus G or T = Factory Installed L = Main Lug 2 = 25 and Surface, Indoor Ground Bar LM = Convertible 5 = 50 F = Flush B = Bottom Feed Main Breaker PL = Main Lug, 20 = 200 S = Surface FL = Factory installed Thermoplastic 22 = 225 R = Outdoor Feed-thru Lugs Enclosure 40 = 40 = Optional door for = 60 circuit indoor panels. (oors 70 = 70 are standard on all other units.) (For details on these and other load centers, see the selection tables on the following pages.) TPL42 C,R TL42 C, R [ HIGHER QULITY. LOWER INSTLLE COST. ] PowerMark Gold Load Centers Catalog number is constructed by adding Suffix and Suffix 2 to Base Catalog Number. 2 F = Flush mount indoor S = Surface mount C = Combination flush/surface mount indoor R, R = Outdoor 3 CU = Copper bus CUFL = Copper bus, feed-thru lugs CUGEN = Copper bus, generator panel with dual main circuit breakers = Optional door for 6- and 8-circuit indoor panels (door standard on outdoor panels)
4 S E L E C T I O N T B L E S. S E L E C T I O N T B L E S. S E L E C T I O N T B L E S. S E L E C T I O N T B L E S. [ SELECTION TBLES. ] PowerMark Gold & Plus Load Centers UL Listed (Panelboards No. 67) 60 C/75 C Conductor Rating Indoor Fronts Combination Surface/Flush Suitable for Use as Service Entrance When Installed in ccordance with the National Electrical Code 22kIC RMS Symmetrical, Except Where Noted Main Lug & Convertible Load Centers Single-phase, Three-wire, 20/240 Volts ac, Top Feed Factory Installed Main Lugs (TLM units convertible to main breaker) PowerMark Plus catalog numbers shown in italics 2 Maximum Spaces Indoor Type Enclosure23 Outdoor Type 3R Enclosure3 Main Main Wire Size Ground Kit mpere THQL Total Box No. Box No. WG/ kcmil Order Separately 2 THQP Rating -pole Cat. No. See Cat. No. See Cu-l See Page 6 p 2p p 2p Spaces Page 24 Page 25 Cat. No TL240SCU4 TL240RCU R 4-4 TGK TL270SCU4 TL270RCU R 6-3 TGK TL42C➄ 2 TL42R➅ R TGL TL42CT➄8 2 TL42RT➅ R TGL Installed TL42R2➅ RB -2/0 TGL TPL42C➄7 2 TPL42R➅7 R TGL TPL42CT➄ 2 TPL42RT➅8 R TGL Installed TLM62FCU, SCU0 3B, 3 TLM62RCU0 R2 TGK TLM82FCU, SCU90 3B, 3 TLM82RCU0 R2 TGK TLM22CCU 4 TLM22RCU R3 TGL TLM22CCUG 4 TGK24 Installed 6-2/ TLM62CCU 4 TGK2 or TGK TLM242CCU 7 TLM242RCU R4 TGK2 or TGK TLM205CCU 8 TGK32-3/0 (Cu) 2-3/0 (l) TLM245CCU 9 TLM245RCU R6 TGK24 or TGK TLM220RCU R5 TGK TLM620CCU 8 TLM620RCU R5 TGK TLM620CCUG 8 TGK32 Installed TLM2020CCU 9 TLM2020RCU R6-250 (Cu) 2/0-250 (l) TGK24 or TGK TLM2020CCUG 9 TGK42 Installed TLM3220CCU 2 TGK TLM4020CCU 3 TLM4020RCU R8 TGK TLM4222CCU 4 TLM4222RCU R8-300 (Cu) 2/0-300 (l) TGK TL2440F,S 6 TL2440R R9 (2) TGL2 (2) 2/ TL4240F,S 2 6 TL4240R 2 R9 (2) TGL TL4260F,S 2 7 TL4260R 2 R9 (2) (Cu) (2) (l) (2) TGL circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For bottom feed door handle, see page amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately (see page 7). 3 TPL load center enclosures are thermoplastic; TL and TLM load center enclosures are galvanized steel. 4 No door. ➄ No door, 0kIC. 6 0 kic. 7 Maximum branch or main circuit breaker rating: 90 amp with Cu, 70 amp with l amp maximum branch capacity. 9 FCU indicates flush mount enclosure; SCU indicates surface mount enclosure. dd to catalog number for optional door (example: TLM62SCU). 0 For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 7. For main breaker, order TQMH000. lso order 2-pole THQL, THHQL or TQL circuit breaker. See page 6. 2 Not suitable for use as service entrance equipment.
5 [ SELECTION TBLES. ] Commercial Load Centers Three-phase, Four-wire, 208Y/20 Volts ac, Top Feed 2 Factory Installed Main Lugs [ SELECTION TBLES. ] Commercial Load Centers PowerMark Plus Load Centers MaximumSpaces Indoor Type Enclosure Outdoor Type 3R Enclosure3 Main Main Ground Kit Wire Size mpere " THQL Total Box No. Box No. Order Separately WG/kcmil Rating -pole Cat. No. See Cat. No. See See Page 6 Cu/l -pole 2-pole 3-pole4 Spaces Page 24 Page 25 Cat. No TL242C 4 TL242R R3 6-2/0 TGL TL845C 6 TL845R R4-3/0 Cu or TGL2+ TGL TL2445C 7 TL2445R R4 2/0-3/0 I TL8420C 7 TL8420R R4 TGL2+ TGL TL30420C 0 TL30420R R6-250 Cu or TL42420C➄ 3 TL42420R➄ R8 2/0-250 I TL30422C➄ Cu or TL42422C➄ 5 TL42422R➄ R8 2/0-300 I TL24440F,S 6 TL24440R R9 (2)2/ TL24440F,S➄ 6 TL42440R➄ R TL42460F,S➄ 7 TL42460R➄ R9 (2) Cu or (2) l lso UL Listed for 3-phase 4-wire 240/20 volts ac delta and 3-phase 3-wire 240 volts ac branch breakers installed circuit indoor devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For bottom feed door handle, see page mp phase and mp 3 phase devices have removable closing cap. Larger mpere devices require field cut openings. Order hubs separately. See page 7. 4 Three pole plug-in breakers available through 00 mps. ➄ Not suitable for use as service entrance equipment. 4 Three-phase, Four-wire, 208Y/20 Volts ac, Top Feed 2 Factory Installed Main Breaker 22kIC RMS Symmetrical PowerMark Plus Load Centers MaximumSpaces Indoor Type Enclosure Outdoor Type 3R Enclosure3 Main Main Ground Kit Wire Size mpere " THQL Total Box No. Box No. Order Separately WG/kcmil Rating -pole Cat. No. See Cat. No. See See Page 6 Cu/l -pole 2-pole 3-pole4 Spaces Page 24 Page 25 Cat. No TM240C 6 6-/0 Cu or TGL TM840C 6 TM840R R4 4-/0 I TGL2+TGL TM3042C TM3042R R7-3/0 Cu or 2/0-3/0 I TM2445C 0 TM2445R R6-3/0 Cu or TM3045C TM3045R R7 2/0-3/0 I TM4245C 3-300MCM Cu or TM24420C 0 R6 2/0-300MCM l TM30420C 2 TM30420R R7-250 Cu or TM42420C 4 TM42420R R8 2/0-250 I TM42422C 5 TM42422R R8-300 Cu or 2/0-300 I TM42430F,S 7 ()6-600 or (2)2/ TM42440F,S 7 TM42440R R ()6-600 or (2)2/ lso UL Listed for 3-phase 4-wire 240/20 volts ac delta and 3-phase 3-wire 240 volts ac branch breakers installed mp phase and mp 3 phase indoor devices available with main breaker bottom mounted at same list price. dd B suffix to catalog number, e.g. TM24420CB. UL Listed mp phase and mp 3 phase devices have removable closing cap. Larger mpere devices require field cut openings. Order hubs separately. See page 7. 4 Three pole plug-in breakers available through 00 mps. Riser Panels 22kIC RMS Symmetrical Maximum Spaces Indoor Type Enclosure Main Main Wire Size Ground Kit mpere THQL Total Box No. WG/ kcmil Order Separately 2 THQP Rating -pole Cat. No. See Cu-l See Page 6 p 2p p 2p Spaces Page 24 Cat. No TLM22CCURP 4 TGK2 or TGK24 6-2/ TLM202CCURP 9 TGK2 or TGK24 Commercial Load Center ccessories ccessory escription Cat. No. Feed-thru Lugs 3-pole, 225, Plug-in2 THLK TMGB24 uxiliary 28 TMGB28 Gutter 33 TMGB33 Enclosures 39 TMGB39 43 TMGB43 43 deep TMGB MCM Lugs TMGT250 Gutter Tap Kits4 500 MCM Lugs TMGT MCM Lugs3 TMGT750 For use with three-phase load centers. 2 22kIC RMS symmetrical. 3 Not for use with riser panels. 4 One tap kit per phase required.
6 imensions (in inches) Box No. Width Height epth R R RB R R R R R R R R R R [ IMENSIONS N KNOCKOUTS. ] PowerMark Gold & Plus Load Centers Outdoor Enclosures Knockouts Symbol B C E F G H J K L M N P Q R S T U V W Y Z BB CC Conduit Size in Inches Mounting provided for universal Hubs HUB [ IMENSIONS N KNOCKOUTS. ] PowerMark Gold & Plus Load Centers W B W Box R W Box R2 G B Box R K 25 Q R K Q Q U R U Q H Box R3, R4, R5, R6, R7 J Box R8 B Box R9 Box R0, R
T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac
More informationT H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.
atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac
More informationSection 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014
Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number
More informationResidential. Section 1.
Load enters Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in ircuit reakers...1-5
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationSection 1. Load Centers and Circuit Breakers.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits... 1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationTHQL1120AF2 THQL1120AF2 Arc Fault BRKR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections
More informationLoad Centers and Circuit Breakers. Section 1.
Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in
More informationFull line. Full service. Full value. GE Residential Products
Full line. Full service. Full value. GE Residential Products [ ONTENTS] Full line, full service, full value................................. 1 Q Line circuit breakers........................................
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationLoad Centers and Circuit Breakers
Midwest lectric Products Load enters and ircuit reakers MLM4020U TQL2140 TQL11202 TQL1115 TQL2120T Midwest Load enters pplication Information Midwest load centers lower your costs by making installation
More informationSection 4 Square D QO Loadcentres
Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationContents. 4 Loadcentres
POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ
More informationRetail Products Catalog
Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product
More informationRetail Reference Guide
www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationQO and HOMELINE Circuit Breaker Load Centers and Enclosures
QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................
More informationLoadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application
Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /
More informationSPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents
SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features
More informationInstalling a Downstream Distribution Panelboard
Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationNEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems
NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely
More informationLearning Module 10: Loadcenters. 101 Basic Series
Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationWestern Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast
Western Section 101 st Annual Meeting Hot Springs, Arkansas September 21, 2005 Charlie Trout Code Breakfast 1.Question: An add on unit for a hydromassage bathtub consists of a small 1-gallon water heater
More informationSERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationSection 8 Stab-lok Circuit Breakers
Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique
More informationLoad Centers
Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our customer s convienience. ll of the urray-branded
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationNQOD Circuit Breaker Panelboards
NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationMolded Case Circuit Breakers Section 3 Q-Line Circuit Breakers
Molded Case Circuit Breakers Section 3 QLine Circuit Breakers Cablein Cableout (luglug) 240V Class TQD 240 Vac, Internal Common Trip # of Ampere 240 Vac Price Poles Rating Interrupting Rating Product Number
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationMain Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS
QO Load Centers > Catalog umber uide QO 1 8 16 M 100 T FT C CP Position 1 rand QO = QO HOM = Homeline Position 2 Phases Only applies to QO lank or 1 = ingle 3 = Three Position 3 paces Maximum number of
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp
More informationSingle- and Three-Phase Through 600 A. Factory Options SUR = Factory integrated surge. Number of 1-Inch (25.4 mm) Spaces. Maximum Number of Circuits
Loadcenters and Circuit reakers Type R Loadcenters and Circuit reakers.2 Standards and Certifications UL Listings ll aton Type R loadcenters are listed under UL File 52977 except the 2 8 circuit loadcenters,
More informationQuik-Spec Coordination Panelboard A fusible panelboards
USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main
More informationApplications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim
Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary
More informationGE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work
GE Energy Industrial Solutions EV Charging Station Application Guide imagination at work EV Charging Station Introduction The GE EV Charging Station offers Level II charging capable of reducing charge
More informationQuik-Spec Coordination Panelboard A fusible panelboards
Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through
More informationModular Metering Application Guide. Meter Mod * III Product Family
Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family
More informationBoxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.
Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts
More informationU075CTL A Surface 50/30/20GFCI Twin Lugs
3804 South Street 75964-7263, TX Nacogdoches hone: 936-569-794 Fax: 936-560-4685 llenwatson@elliottelectric.com U075TL00 00 Surface 50/30/20GFI Twin Lugs Midwest Electric roducts atalog Number Manufacturer
More informationSection 3: Molded Case Circuit Breakers
Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference
More informationSection 2 HomeLine Loadcentres
Section 2 HomeLine Loadcentres Features that Outclass the Competition The quality you expect from Schneider Electric, the industry leader, is built into all HomeLine loadcentres. One example is our exclusive
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationfastfax Rock Solid TM Load Centers General Information
General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.
More informationSingle Socket and Horizontal Metering
GE Energy onnections Single Socket and Horizontal etering EP pproved Single Socket etering EP pproved pplication Information GE s Single Socket etering products are designed for residential use. They are
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationQuik-Spec Electrical Gear
Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationIntroduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3
Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationCircuit Breaker Accessories BREQS125 BRHDK125
anuary 2008 Loadcenters & ircuit reakers Type R Loadcenters & ircuit reakers ircuit reaker ccessories -75 ircuit reaker ccessories TS LW2 RLW2 RQS25 TOW (nstalled) MPL (nstalled) RQLW LW RK25 RML Table
More informationNQOD Circuit Breaker Panelboards
Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection...
OEM Loadcenters Contents s and Certiications................. Product Selection......................... Page V-T-83 V-T-83 Product s a leader in the electrical distribution equipment business, Eaton has
More informationPow-R-Line 3E Panelboard
This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided
More informationQuik-Spec Coordination Panelboard Specifications
Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationSection 7. Circuit Breaker Enclosures. BuyLog Catalog 7-1
NEMA Type 1 Enclosures... 7-2 NEMA Type 3R Enclosures...7-3 NEMA Type 12 Enclosures...7-4 NEMA Type 4/4X Enclosures... 7-5 Hubs and Other Accessories... 7-6 Dimensions and Outline Drawings...7-7 Dimensions
More information4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering
Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant
More informationPanelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description
.5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationPanelboards Circuit Breaker / Lighting and Distribution
Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationCircuit Breaker Enclosures. Section 4.
Circuit Breaker Enclosures Section 4 NEMA Type 1 Enclosures...4-2 NEMA Type 3R Enclosures...4-3 NEMA Type 12 Enclosures...4-4 NEMA Type 4/4X Enclosures...4-5 Hubs and Other Accessories...4-6 Dimensions
More informationLaser Service Factory-assembled Panelboards
Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page
More information!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages
FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4
More informationFor Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses
mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More information22.000A IR. Catalog Number. Price $
Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationTypical AEP Panelboard
Typical AEP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual
More informationGE Energy. GE Panelboards. The right panelboard for any application. imagination at work
GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationPANELBOARDS SECTION 1
SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector
More informationQuik-Spec. Section Contents
Section Contents Page Quik-Spec Coordination Panel Boards......... 238-239 Quik-Spec Power Module Switches and Panels.. 240-241 Quik-Spec DC Safety Switches.................. 242 Quik-Spec Solar Combiner
More informationCABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,