2 Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9 TMPC Meter Stack Modules TMPC Residential Meter Stack Modules TMPC Main Tenant Circuit Breakers Commercial Meter Stack Modules TMPC Meter Stack Accessories Meter Centre Diagrams and Dimensions Meter Centre Wiring Diagrams Ordering Information

3 Meter Centres and Tenant Breakers Meter Centre Tap Boxes for 4 Jaw, 5 Jaw and 7 Jaw Stacks (jumper kits and ground bus kits NOT required) TMPC3L4R Tap box 400A max., 1ph or 3ph; (1) 600MCM max or (2) 250MCM max. TMPC3L6R Tap box 600A max., 1ph or 3ph; (2) MCM max. TMPC3L8R Tap box 800A max., 3ph; (4) MCM Note: Use this tap box when 3 X 250MCM at 600A TMPC3FT8 Feed-thru tap box 800A max., 1ph or 3ph; (4) MCM in and out Meter Centre and Tenant Breakers for 5 Jaw and 4 Jaw Stacks (jumper kits and ground bus kits NOT required) TMPC8612R Meter stack, 6HI, 125A max., 5 Jaw, 3ph Hor. Bus; note: 3ph incoming TMPC8312R Meter stack, 3HI, 125A max., 5 Jaw, 3ph Hor. Bus; note: 3ph incoming TMPC612R Meter stack, 6HI, 125A max., 4 Jaw, 1ph Hor. Bus; note: 3ph incoming TMQRL P 100A stack brk for 125A stacks, 208v TMQRHL P 100A stack brk for 125A stacks, 208v TMQRL P 125A stack brk for 125A stacks, 208v TMQRHL P 125A stack brk for 125A stacks, 208v Meter Centre and Tenant Breakers for 7 Jaw Stacks (jumper kits and ground bus kits NOT required) TMPC312410R Meter stack, 4HI, 100A max., 7Jaw, 3ph in and out TMQG P 100A stack brk for 100A stacks, 208v TMPC312420R Meter stack, 4HI, 200A max., 7Jaw, 3ph in and out TMQE P 100A stack brk for 200A stacks, 208v TMQE P 125A stack brk for 200A stacks, 208v TMQE P 150A stack brk for 200A stacks, 208v TMQE P 200A stack brk for 200A stacks, 208v Meter Centre Accessories for all Stacks TMPCP Blank Meter socket cover 2

4 Industrial Multi-Metering Designed for Main and Sub-Service switching and Metering of residential, commercial, and industrial applications. Suitable for single-phase, three-wire 120/240 Vac or three-phase, four-wire 120/208 Vac systems, and sub service ratings of 100, 125 and 200 Amp. Available with a selection of Meter modules that have three or six Meter sockets and a main service module that can be provided with a choice of Lug, Breaker or Fusible device. Metering also available for applications that require 7 jaw, 3 phase in, 3 phase out [4w/4w] with one or four socket(s). GE Industrial Meter centres are designed to meet CSA requirements for cold Metering. 3

5 Main Service Modules Main Service Modules - 5 Jaw and 7 Jaw Design Offering: main terminal/lug compartment, main circuit breaker, main fusible switch. Mechanically and electrically built for use with TMPC modular Metering stacks. Due to 800A cross bus rating on 5 Jaw design, if main is rated higher than 800A, modular Metering stacks must be centre fed from the main service module. Type 3R enclosure (rainproof). Residential Modular Metering Stacks - 5 Jaw Design Mechanically and electrically built to bolt-up with main service modules and commercial modular Metering stacks. Offered with four horizontal cross bus (for 3-phase incoming voltage systems). All devices include fifth jaw as standard Type 3R enclosure (rainproof). 4

6 Main Service Modules Commercial Modular Metering Stacks - 7 Jaw Design Mechanically and electrically built to bolt-up with main service modules and commercial modular Metering stacks. All commercial modular Metering stacks contain four horizontal cross. Applications: - Light commercial multiple Metering projects - 3ph in 3ph out (4W/4W) - Type 3R enclosure bus. 5

7 Main Service Modules Main Service Modules Main Terminal Box Main Terminal Box. Main Circuit Breaker. Main Fusible Switch. Three-phase mains couple to any modular Metering stack TMPC for both 5 and 7 jaw stacks. 3-phase mains require 3-phase bussed stacks. These modular Metering stacks are TMPC styles. Since TMPC 5 Jaw Meter stacks have a horizontal bus rating of 800A, any main device rated more than 800A needs to centre feed these downstream Meter stacks. Enclosures EEMAC, 3R. All main service modules include both left and right horizontal bus closure plates. Feed through cable connection tap box available for TMPC design. For Service Entrance rating or grounding, use GRDKIT. Main Circuit Breaker Main Fusible Switch 6

8 Main Terminal Boxes Main Terminal Box Top/bottom feed Phase and neutral lugs included with the following devices. Terminal box CSA listed short circuit rating is the least AIC rating of any installed main tenant breaker - to a maximum of 100 kaic RMS symmetrical amperes. Enclosure type 3R rainproof, order Myers type hubs for outdoor use. Refer to page 17 for dimensions. Ampere Rating 120/240V AC 1-Phase, 3-Wire System Voltage 120/208V AC 3-Phase, 4-Wire Line Side Lug and Wire Sizes Lugs included with Terminal Box 400 Use 3 Phase TMPC3L4R (1) #6-600 kcmil or (6) (7) (2) 1/0-250 kcmil 600 Use 3 Phase TMPC3L6R (2) kcmil 800 TMPCL8R TMPC3L8R (4) kcmil 1200 TMPCL12R (1) TMPC3L12R (1) (4) kcmil (1) Main devices with a rating of greater than BOOA can be used in centre feed applications only with residential type Meter stacks. (2) To obtain (4) 1/0-300 kcmil or (2) 1/0-750 kcmil cables per phase - order catalogue number TMPP3L8BLK, one lug kit per cable tap box required. (3) To obtain (6) 1/0 300 kcmil or (3) 750 kcmil cables per phase - order catalogue number TMPP3L12BLK, one lug kit per cable tap box required. (4) For compression lug landing kit, order TMPPLK2 Kit includes lug landings for 3 phases and neutral (5) For compression lug landing kit, order TMPP3LKBLK. Kit includes lug landings for 3 phases and neutral. (6) To obtain (1) 750 kcmil cables per phase - order catalogue number TMPPLK2,one lug kit per pole or neutral required. (7) To obtain (3) 1/0-250 kcmil cables per phase - order catalogue number 3MTB600BLK, one lug kit per cable tap box required. (4) (6) (7) (2) (5) (3) (5) 7

9 Main Circuit Breakers Main Circuit Breaker Phase and neutral lugs included with the following devices. Top/Bottom feed. For shunt trip mains, order the field installable shunt trip kit. Main breaker included. Enclosure type 3R use Myers type hubs for outdoor use. Can be factory supplied as Reverse Fed. Must be specified at time of purchase. Main Ampere Rating Main Circuit Breaker Type Feed A/C 120/240V AC 1-Phase 3-Wire System Voltage 120/20BV AC a-phase 4-Wire Catalogue # Catalogue # 200 SGH Top/Bottom 65k TMPCSB4R + SRPG400A200 TMPC3SB4R + SRPG400A SGH Top/Bottom 65k TMPCSB4R + SRPG400A250 TMPC3SB4R + SRPG400A250 SGH Top/Bottom 100k TMPCSHB4R + SRPG400A250 TMPC3SHB4R + SRPG400A250 SGH Top/Bottom 65k TMPCSB4R + SRPG400A300 TMPC3SB4R + SRPG400A300 SGL Top/Bottom 100k TMPCSHB4R + SRPG400A300 TMPC3SHB4R + SRPG400A300 SGH Top/Bottom 65k TMPCSB4R + SRPG400A350 TMPC3SB4R + SRPG400A350 SGL Top/Bottom 100k TMPCSHB4R + SRPG400A350 TMPC3SHB4R + SRPG400A350 SGH Top/Bottom 65k TMPCSB4R (2)(6) TMPC3SB4R (2)(6) SGL Top/Bottom 100k TMPCSHB4R (2)(6) TMPC3SHB4R (2)(6) SGH Top/Bottom 65k TMPCSB6R + SRPG600A500 TMPC3SB6R + SRPG600A500 SGL Top/Bottom 100k TMPCSHB6R + SRPG600A500 TMPC3SHB6R + SRPG600A500 SGH Top/Bottom 65k TMPCSB6R (2) TMPC3SB6R (2) SGL Top/Bottom 100k TMPCSHB6R (2) TMPC3SHB6R (2) (1) Main devices with a rating of greater than 800A can be used with residential modular stacks but only as a centre fed main. (2) Add CL to end of catalogue number for compression lug pad (includes lug pads for lines and neutral). (3) If (3) kcmil are needed, order TCAL124. Order one kit per pole. (4) If additional neutral lugs are needed, order TMP3B12NLK [(3) 1/0-750 kcmil or (6) 1/0-300 kcmil]. (5) If (2) kcmil are needed, order TCAL124. Order one kit per pole. (6) If (1) 750 kcmil are needed, order 800 Amp SK frame/400 Amp Rating Plug and TCAL124 Lugs. Line Side Lug and Wire Sizes, Lugs included with Main Breaker (2) 3/0-250 kcmil or (1) 2/0-500 kcmil (4) (2) kcmil (4) 700 SKH Top/Bottom 65k TMPCSB8R + SRPK800A700 TMPC3SB8R + SRPK800A700 (3) kcmil 800 SKH Top/Bottom 65k TMPCSB8R (2) TMPC3SB8R (2) 900 SKH Top/Bottom 65k TMPCSB10R (1)(2) + SRPK1200A900 TMPC3SB10R (1)(2) + SRPK1200A SKH Top/Bottom 65k TMPCSB10R (1)(2) TMPC3SB10R (1)(2) 1200 SKH Top/Bottom 65k TMPCSB12R (1)(2) TMPC3SB12R (1)(2) (4) 4/0-500 kcmil (4) (5) (3) (4) 8

10 Main Fusible Switches Main Fusible Switches Fuses not included. Main lugs and neutral included with device. Enclosure type 3R rainproof, order Myers type hubs (page 12) for outdoor use. 100 kaic rating on switches with Class T fuses installed. If converted to Class H, the AIC rating is 10k and if converted to Class R, or J fusing the AIC rating is 200k. Ampere Rating Feed 120/240V AC 1-Phase, 3-Wire System Voltage 120/20BV AC 3-Phase, 4-Wire Catalogue # Catalogue # Class Fuse Clips Fuses Not Included Line Side Box Lugs and Wire Sizes included with Switch Bottom TMPCFB4R TMPC3FB4R T (1) (2) 1/0-300 kemil or (1) 750 kcmil (4) Top TMPCFT4R TMPC3FT4R T (1) (2) 1/0-300 kemil or (1) 750 kcmil (5) Bottom TMPCFB6R TMPC3FB6R T (2) (2) #2-600 kcmil (4)(7)(9) Top TMPCFT6R TMPC3FT6R T (2) (2) #2-600 kcmil (5)(7) Bottom TMPCFB8R TMPC3FB8R T (2) (4) #3/0-750 kcmil (4) Top TMPCFT8R TMPC3FT8R T (2) (4) #3/0-750 kcmil (5) 1200 Bottom TMPCFB12R (6) TMPC3FB12R (6) L (4) #2 to 500 kcmil (8) (1) If Class H fuse clips are needed, use catalogue number WCG3HK400. If Class R fuse clips are needed, order catalogue number DS56FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. Kits are field installable and each kit will convert 1 pole. (2) If Class H fuse clips are needed, use catalogue number WCG3HK600. If Class R fuse clips are needed, order catalogue number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. Kits are field installable and each kit will convert 1 pole. NOTE: Class J Fuse Clip Kit for 400 and 600A use TMPCJ6 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. (3) lf compression lugs are being used, order TMPP3F8CLL1. This compression lug kit includes four pads (3 poles and neutral). (4) If compression lugs are being used, order 3MFS800CLKT Top Feed. This compression lug kit includes four pads (3 poles and neutral). (5) For top feed application cables must be looped. (6) To obtain (1) 750 kcmil order 1 MFS600BLK one lug kit per pole required. (7) To obtain (3) 750 kcmil cable per phase order TMPIF12NLK, one lug kit per pole required. (8) If additional neutral lugs needed order 1MFS1200LKN (3) 750 kcmil! cables per phase. 9

11 TMPC Meter Stack Modules A. Barrier Meter socket and tenant main breaker/wireway sections are separated by a solid metal barrier to guard unmetered bus against power theft. B. Tenant Breaker Reliable busbar-to-busbar connection. 200 ampere modules accept bolt-on breakers (not Sal) amperes. 125 ampere modules accept ampere plug-on breakers. C. Factory Phase Balanced All Meter centres are factory phase balanced for ease and speed of installation. D. Neutral Assembly A convenient termination for neutral conductors is in the wireway of each module. E. Enclosed Horizontal Bus Added security because a nonremovable barrier exercises 800 ampere horizontal bus passing through tenant breaker section on 5 Jaw design. F. Equipment Ground Bar Factory installed in side gutter, a standard feature that s movable to the top or bottom gutter. G. Continuous Ground A convenient lay-in lug is attached to the back of all cells. No longer do you need to purchase ground bar kits. Just remove knockouts and run your ground cable from cell to cell. H. Raintight Cap Shipped on all TMPC Meter modules. Enclosure type 3R rainproof. I. Knockouts Tangential in top and bottom, concentric in removable backwall plate J. Superior Finish Rust inhibiting phosphate primer and grey baked enamel is standard. All outdoor enclosures are of galvanized steel construction K. Meter Socket Our unique Meter socket base is installed without any fasteners reducing chances for hot spots, easily replaceable, and improves connection to vertical bus. L. Bus Connection Mains and modules slip together quickly, smoothly with front-accessible captive bolts securing the juncture without removing socket interiors or bus access plate. No additional Bus Links required. Main bus joint bolts torque to 25 foot pounds. M. Separate Wireway Cover Separate covers allow easy access to tenant breaker and wireway section, permit work on breakers or in wireway without disturbing Meters or Meter covers (not shown). N. Vertical Busbar One-piece vertical busbar removes most of the standard electrical joints to the Meter socket. Eliminating any chance of hot spots from multiple connection points. O. Horizontal Mounting Rail To speed up and simplify installations, a two piece Mounting Rail is included with each Meter stack. Swing away feet located at the top and bottom of structure can be utilized for wall mounting (not shown). P. Padlock HASP Included for additional security when required (not shown). 10

12 TMPC Residential Meter Stack Modules - 5 Jaw Design TMPC Residential Meter Stack Modules - 5 Jaw Design Stacks with 1-phase horizontal bus are rated 240/120V, 1-phase, 3-wire. Stacks with 3-phase horizontal bus are rated 208Y/120V, 3-phase, 4-wire but can be used on 240/120V, 3-phase, 4-wire delta systems. All 3-phase horizontal bus modules have 4-wire, 800A cross bus and all stacks are factory balanced for ease of installation. Short circuit ratings up to 100,OOOA RMS symmetrical depending upon Ale rating of installed main tenant circuit breakers and main device. Lay-in Lug is attached to back of every cell. Removal of K/O allows ground cable to run from cell to cell. Main tenant feeders can exit top or bottom. Knockouts are available at all exit locations. Type 3R enclosure. If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap. Provision for 2-pole breaker. Plug-on type for 125A Meters and bolt-on type for 200A Meters. Circuit breakers not included. Available in three and six Meter socket configuration, 5 jaw standard. Amperes per Meter Socket 125 Number of Meter Sockets 3 Bus Ampacity Enclosure Type Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor 1-Phase Horizontal Bus (3 Horizontal Bus Bars - A, B and Neutral) (1) Fifth jaw at 9 o clock position included as standard. Can be field adjusted to the 3, or 6, or 12 o clock position. 3-Phase Horizontal Bus (4 Horizontal Bus Bars - A, B, C and Neutral) Main Tenant Breaker Type For Specific Catalogue Number refer to pages 22 to 23 (1) - TMPC8312R Plug on Type TMQRL TMQRHL TMPC612R (1) TMPC8612R (1) TMQL TMPC320R (1) TMPC8320R (1) TMQRD TMQ Bolt-on Type TMQRHD Wire Sizes: Neutral and Ground Lugs Each stack includes a neutral and ground bar. If an extra ground bar is needed order 1 MMGBK Lug in Meter Socket Modules Wire Size, AI/Cu Branch Neutral #6-2/0 125A socket module Branch Neutral #1/0-300 kcmil 200A socket module Equipment Ground Bar #14-#2 125A socket module Equipment Ground Bar #14-2/0 200A socket module Optional Ground Bar (1 MMGBK) #6-2/0 11

13 TMPC Main Tenant Circuit Breakers 5 Jaw Design TMPC Main Tenant Circuit Breakers 5 Jaw Design The following breakers are to be used on TMPC6 and TMPC8 modular Metering stacks. 120/240V AC - field installed. Plug-in type circuit breakers used with TMPC 125A modular stacks (1) (2) Bolt-on circuit breakers used with TMPC 200A modular stacks # of Poles Main Tenant Circuit Breaker Ampere Rating 10,000 AIC 22,000 AIC 25,000 AIC 42,000 AIC 100,000 AIC Catalogue Number Catalogue Number Catalogue Number Catalogue Number 2 60 TMQRL2160 TMQRHL TMQL TMQRL2170 TMQRHL TMQL TMQRL2180 TMQRHL TMQL TMQRL2190 TMQRHL TMQL TMQRL21100 TMQRHL TMQL TMQRL21110 TMQRHL TMQL TMQRL21125 TMQRHL TMQL Catalogue Number TMQV22060MM TMQV22070MM TMQV22080MM TMQV22090MM TMQRD TMQRHD TMQV22100MM TMQRD TMQRHD TMQV22125MM TMQRD TMQRHD TMQV22150MM TMQRD TMQRHD TMQV22175MM TMQRD TMQRHD TMQV22200MM TMQV22225MM TMQV TMQV TMQV TMQV TMQV TMQV TMQV TMQV TMQV TMQV32225 (1) Mounting hardware kit for TMQRD AND TMQRHD type (bolt-on) breakers included in 200A Meter stack. (2) Load side lugs included with 200 Amp Stack Breaker. Feed through Cable Connection Tap Box - 5 Jaw and 7 Jaw Design Ampere Rating Entry Side System Voltage 120/208V 3ph 4W H W D 800 Top/Bottom TMPC3FT8 (1) 46 1/8 26 1/2 8 1/2 Conductors Per Phase CU/AL IN and OUT Lugs supplied with Box (4) kcmil IN (4) kcmil OUT 1200 Top/Bottom TMPC3FT12 (2) 50 3/4 26 5/8 9 same as above 1) To obtain (4) 1/0-750 kcmil or (8) 1/0-300 kcmil cables per phase - order catalogue number TMPCFT8LUG. 2) To obtain (3) #2-750 kcmil (2 in/2 out) cables per phase - order catalogue number TMPCFT12LUG. NOTES: Feed through Tap Boxes are required when cables enter and exit at the same end of the Meter Centre. No KO s are provided. Cable connection Tap Boxes may be used for Subfeeds. Mount on opposite end to main cable entry. 12

14 TMPC Main Tenant Circuit Breakers - 7 Jaw Design TMPC Main Tenant Circuit Breakers - 7 Jaw Design The following breakers are to be used on TMPC 7 Jaw modular Metering stacks. 120/208V AC - field installed. Use 3 pole tenant breaker (see chart below) Bolt-on type circuit breakers used with TMPC 7Jaw 100A Modular Metering Stacks Bolt-on circuit breakers used with TMPC 7Jaw 200A Modular Metering Stacks Number of Poles Main Tenant Circuit Breaker Ampere Rating 65,000 AIC 100,000 AIC Catalogue # Catalogue # 3 60 TMQG TMQG TMQG TMQE TMQE TMQE TMQE TMQE32200 NOTE: Reference to Bolt-on Breakers, is not the former BQL frame, it represents a commercial grade Bolt-on moulded case frame. 1) Mounting hardware kit for TMQE type breakers included in 200A Meter stack. TMQG mounting hardware is included with the breakers. 2) Mounting hardware kit includes 3TA225FD (#4-4/0) lugs for standard 200A applications. If other lugs are required, they must be purchased separately. Consult GE Feed Through Cable Connection Tap Boxes - TMPC Design Ampere Rating Entry Side System Voltage 120/208V 3ph 4W H W D 800 Top/Bottom TMPC3FT8 (1) 46 1/8 26 1/2 8 1/2 1) To obtain (4) 1/0-750 kcmil or (8) 1/0-300 kcmil cables per phase - order catalogue number TMPCFT8LUG. 2) To obtain (3) #2-750 kcmil (2 in/2 out) cables per phase - order catalogue number TMPCFT12LUG. NOTES: Feed through Tap Boxes are required when cables enter and exit at the same end of the Meter Centre. No KO s are provided. Cable connection Tap Boxes may be used for Subfeeds. Mount on opposite end to main cable entry. Conductors Per Phase CU/AL IN and OUT Lugs supplied with Box (4) kcmil IN (4) kcmil OUT 1200 Top/Bottom TMPC3FT12 (2) 50 3/4 26 5/8 9 same as above 13

15 Commercial Meter Stack Modules - TMP Series 7 Jaw Design Commercial Meter Stack Modules - TMP Series 7 Jaw Design TMP Series Commercial Meter Stack Modules: 7 Jaw Meter stacks are available in 100 and 200 amps. 3 phase in, 3 phase out (4W/4W), 240V AC max. Short circuit ratings up to 100,000A RMS symmetrical depending upon AIC rating of installed main tenant circuit breakers and main device. Lay-in Lug is attached to the back of every cell. Removal of K/O allows ground cable to run from cell to cell. Main tenant feeders can exit top or bottom. Knockouts are available at all exit locations. Type 3R enclosure. If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap. Wire Sizes: Neutral and Ground Lugs Lugs in Meter Socket Modules Wire Size, AI/Cu Branch Neutral - #1/0-300MCM 100A Socket Module Branch Neutral - #1/0-300MCM 200A Socket Module Equipment Ground Bar #6-2/0 100A Socket Module Equipment Ground Bar #6-2/0 200A Socket Module Optional Ground Bar (1 MMGBK) #6-2/0 Each stack includes a neutral and ground bar. If an extra ground bar is needed order 1 MMGBK Amperes per Meter Socket Number of Meters per Stack Bus Ampacity Enclosure Type 3-Phase Horizontal Bus (4 Horizontal Bus Bars - A, B, C and Neutral) Main Tenant Breaker Type For Specific s Indoor & Outdoor TMPC312410R Bolt on Type TMQG 3 pole Indoor & Outdoor TMPC312120R Indoor & Outdoor TMPC312420R Bolt on Type TMQE 3 pole 14

16 TMPC Meter Stack Accessories Accessories for TMPC Modular Metering Stacks Application Lexan Blank Cover Circular cover mounted on device preventing access to Meter socket while Meter is not in place. Includes 4 plastic. TMPCP Wall Mounting Rail Rails are 4 feet ( mm) in length. Bolted on wall for stacks and mains to be hung. TMPZR Indoor Corner Elbow 12 inch (303.8mm) indoor corner elbow ampere, 3-phase, 4-wire. TMPCE12A Indoor Corner Elbow 16 inch (406.4mm) indoor corner elbow ampere, 3-phase, 4-wire. TMPCE12 Lexan Blank Cover without tabs Blank Meter Socket Cover 1PH 125A TMPCB12B Blank Meter Socket Cover 1PH 200A TMPCB20B Blank Meter Socket Cover 3PH 100A TMPCB310C Blank Meter Socket Cover 3PH 200A TMPCB320C TMPCA Lexan Blank Cover Wall Mounting Rail Indoor Corner Elbow 15

17 Meter Centre Diagrams and Dimensions Main Service Modules Main Circuit Breakers, Terminal Boxes Bottom Feed Fusible Switch Top Feed Fusible Switch 16

18 Meter Centre Diagrams and Dimensions Approximate Dimensions (not to be used for construction purposes) Main Device Terminal Box Width Height Depth Mounting Centre Line of Wall Mounting Bracket A B C D E F Knock-Outs in Bottom End walls except No KOs for Top Feed Switch Conduit DiaMeter-Inches inches mm inches mm inches mm inches mm inches mm inches mm inches mm 400 & 600 Ampere 13-1/ / / Terminal Box 800 & 1200 Ampere Main Circuit Breaker with Box Lugs 400 & 800 Ampere Main Circuit Breaker with Compression Lugs 400 & 800 Ampere Main Fusible Switch - Bottom Feed Main Fusible Switch - Top Feed Main Fusible Switch Ampere / / / / / / / / / / / / / / / / / / / / / (1) 2-1/ /2, 4 (1) 1/2 (2) 1/2-3/4-1 (4) /2-4 (2) 1/2-3/4-1 (4) /2-4 (2) 1/2-3/4-1 (4) 2 2-1/2-3-1/2-4 (2) 1/2-3/4-1 (4) 2 2-1/ /2-4 (2) 1/2-3/4-1 (4) 2 2-1/ /2-4 (5) 3-1/2-4-5 (1) 3/ /4-1-1/2 (1) (1) 12.7 (2) (4) (2) (4) (2) (4) (2) (4) (2) (4) (5) (1)

19 Meter Centre Diagrams and Dimensions TMPC, 125A - 5 Jaw Design TMPC8312R TMPC612R / TMPC8612R TMPC, 200A - 5 Jaw Design TMPC, 100A & 200A - 7 Jaw Design TMPC312120R TMPC320R / TMPC8320R TMPC312420R / TMPC312410R 18

20 Meter Centre Wiring Diagrams Wiring Diagrams & Typical Nameplate Information (240VAC max.) All GE meter centres are factory phase balanced 19

21 Ordering Information Meter Stacks TMPC612R TMPC320R TMPC8612R TMPC8312R TMPC8320R TMPC312410R TMPC312120R TMPC312420R 6HI 125A 4jaw, 800A 1ph hor Bus 3HI 200A 4jaw, 800A 1ph hor Bus 6HI 125A 5jaw, 800A 3ph hor Bus 3HI 125A 5jaw, 800A 3ph hor Bus 3HI 200A 5jaw, 800A 3ph hor Bus 4HI 100A 7jaw, 1200A 3ph hor Bus 1HI 200A 7jaw, 1200A 3ph hor Bus 4HI 200A 7jaw, 1200A 3ph hor Bus Feed Through Cable Tap Boxes TMPC3FT8 TMPC3FT12 Feed Through Lugs TMPCFT8LUG TMPCFT12LUG 800A 3ph Feed Thru Tap Box 1200A 3ph Feed Thru Tap Box 800A 750mcm Lug Kit Feed Thru 1200A 750mcm Lug Kit Feed Thru Tap Boxes TMPCL8R 800A 1ph Main Lug Module 1/3R TMPCL12R 1200A 1ph Main Lug Module 1/3R TMPC3L4R 400A 3ph Main Lug Module 1/3R TMPC3L6R 600A 3ph Main Lug Module 1/3R TMPC3L8R 800A 3ph Main Lug Module 1/3R TMPC3L12R 1200A 3ph Main Lug Module 1/3R Elbow Section TMPCE12A TMPCE A 3ph Bussed Elbow A 3ph Bussed Elbow 20

22 Ordering Information Main Breaker Section TMPCSB4R TMPCSHB4R TMPCSB6R TMPCSHB6R TMPCSB8R TMPCSB10R TMPCSB12R TMPC3SB4R TMPC3SHB4R TMPC3SB6R TMPC3SHB6R TMPC3SB8R TMPC3SB10R TMPC3SB12R 400A Main Bkr 1 Ph 240V 42KAIC 400A Main Bkr 1Ph 240V 100KAIC 600A Main Bkr 1 Ph 240V 42KAIC 600A Main Bkr 1 Ph 240V 100KAIC 800A Main Bkr 1 Ph 240V 65KAIC 1000A Main Bkr 1 Ph 240V 65KAIC 1200A Main Bkr 1 Ph 240V 65KAIC 400A Main Bkr 3Ph 240V 42KAIC 400A Main Bkr 3Ph 240V 100KAIC 600A Main Bkr 3Ph 240V 42KAIC 600A Main Bkr 3Ph 240V 100KAIC 800A Main Bkr 3Ph 240V 65KAIC 1000A Main Bkr 3Ph 240V 65KAIC 1200A Main Bkr 3Ph 240V 65KAIC Main Switch Section TMPCFB4R TMPCFT4R TMPCFB6R TMPCFT6R TMPCFB8R TMPCFT8R TMPCFB12R TMPC3FB4R TMPC3FT4R TMPC3FB6R TMPC3FT6R TMPC3FB8R TMPC3FT8R TMPC3FB12R 400A Main Sw 1 Ph 240V Bot Feed 400A Main Sw 1 Ph 240V Top Feed 600A Main Sw 1 Ph 240V Bot Feed 600A Main Sw 1 Ph 240V Top Feed 800A Main Sw 1 Ph 240V Bot Feed 800A Main Sw 1 Ph 240V Top Feed 1200A Main Sw 1 Ph 240V Bot Fed 400A Main Sw 3Ph 240V Bot Feed 400A Main Sw 3Ph 240V Top Feed 600A Main Sw 3Ph 240V Bot Feed 600A Main Sw 3Ph 240V Top Feed 800A Main Sw 3Ph 240V Bot Feed 800A Main Sw 3Ph 240V Top Feed 1200A Main Sw 3Ph 240V Bot Fed 21

23 Ordering Information Accessories TMPCP TMPZR TMPC12 TMPC20 TMPBC12 TMPBC20 TSPR3 TMPPLK2 TMPP3L8BLK TMPP3L12BLK TMP3B12NLK TMPP3F8CLL1 TMP3F12NLK TMP1F12NLK TMPCJ6 Lexan Blank Cover Wall Mounting Rail - Resi Style 125A Ring Cover 200A Ring Cover 125A Tenant Breaker Cover 200A Tenant Breaker Cover Sealing Ring-Stnless Screw type 600A 750mcm Lug Kit 800A 750mcm Main Lug Kit 1200A 750mcm Main Lug Kit Neutral Lug Fs Sw Compression Lug Landings 1200A 750mcm Fs Sw Neutral kit 1200A 750mcm Fs Sw Lug Kit J Fuse Clips 400AMP / 600AMP Circuit Breakers TMQRL2160 TMQRL2170 TMQRL2180 TMQRL2190 TMQRL21100 TMQRL21110 TMQRL21125 TMQRHL2160 TMQRHL2170 TMQRHL2180 TMQRHL2190 TMQRHL21100 TMQRHL21110 TMQRHL A 2P 120/240V 10KAIC TMQRL 70A 2P 120/240V 10KAIC TMQRL 80A 2P 120/240V 10KAIC TMQRL 90A 2P 120/240V 10KAIC TMQRL 100A 2P 120/240V 10KAIC TMQRL 110A 2P 120/240V 1 OKAIC TMQRL 125A 2P 120/240V 1 OKAIC TMQRL 60A 2P 120/240V 22KAIC TMQRHL 70A 2P 120/240V 22KAIC TMQRHL 80A 2P 120/240V 22KAIC TMQRHL 90A 2P 120/240V 22KAIC TMQRHL 100A 2P 120/240V 22KAIC TMQRHL 110A 2P 120/240V 22KAIC TMQRHL 125A 2P 120/240V 22KAIC TMQRHL 22

24 Ordering Information Circuit Breakers TMQL2160 TMQL2170 TMQL2180 TMQL2190 TMQL21100 TMQL21125 TMQRD22100 TMQRD22125 TMQRD22150 TMQRD22175 TMQRD22200 TMQRHD22100 TMQRHD22125 TMRHD22150 TMQRHD22175 TMQRHD22200 TMQV22060MM TMQV22070MM TMQV22080MM TMQV22090MM TMQV22100MM TMQV22125MM TMQV22150MM TMQV22175MM TMQV22200MM TMQV22225MM TMQV32060 TMQV32070 TMQV32080 TMQV32090 TMQV32100 TMQV32125 TMQV32150 TMQV32175 TMQV32200 TMQV32225 TMQE32100 TMQE32125 TMQE32150 TMQE32175 TMQE32200 TMQG32060 TMQG32070 TMQG A 2P 120/240V 42KAIC 70A 2P 120/240V 42KAIC 80A 2P 120/240V 42KAIC 90A 2P 120/240V 42KAIC 100A 2P 120/240V 42KAIC 125A 2P 120/240V 42KAIC 100A 2P 120/240V 10KAIC TMQRD 125A 2P 120/240V 10KAIC TMQRD 150A 2P 120/240V 1 OKAIC TMQRD 175A 2P 120/240V 10KAIC TMQRD 200A 2P 120/240V 1 OKAIC TMQRD 100A 2P 120/240V 25KAIC TMQRHD 125A 2P 120/240V 25KAIC TMQRHD 150A 2P 120/240V 25KAIC TMQRHD 175A 2P 120/240V 25KAIC TMQRHD 200A 2P 120/240V 25KAIC TMQRHD 60A 2P 120/240V 100KAIC 70A 2P 120/240V 100KAIC 80A 2P 120/240V 100KAIC 90A 2P 120/240V 100KAIC 100A 2P 120/240V 100KAIC 125A 2P 120/240V 100KAIC 150A 2P 120/240V 100KAIC 175A 2P 120/240V 100KAIC 200A 2P 120/240V 100KAIC 225A 2P 120/240V 100KAIC 60A 3P 120/240V 100KAIC 70A 3P 120/240V 100KAIC 80A 3P 120/240V 100KAIC 90A 3P 120/240V 100KAIC 100A 3P 120/240V 100KAIC 125A 3P 120/240V 100KAIC 150A 3P 120/240V 100KAIC 175A 3P 120/240V 100KAIC 200A 3P 120/240V 100KAIC 225A 3P 120/240V 100KAIC 100A 3P 208V 65KAIC for 200A - 7 jaw stack 125A 3P 208V 65KAIC for 200A - 7 jaw stack 150A 3P 208V 65KAIC for 200A - 7 jaw stack 175A 3P 208V 65KAIC for 200A - 7 jaw stack 200A 3P 208V 65KAIC for 200A - 7 jaw stack 60A 3P 208V 65KAIC for 100A - 7 jaw stack 70A 3P 208V 65KAIC for 100A - 7 jaw stack 100A 3P KAIC for 100A - 7 jaw stack 23

25 Section 2 NOTES: 24

26 GE 41 Woodford Avenue Plainville, CT Information provided is subject to change. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. 2018, General Electric Company and/or its affiliates. All rights reserved DET1032

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module,

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers

More information

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

American Electric Supply, Inc.

American Electric Supply, Inc. American Electric Supply, Inc. 6 S. Maple Street Date: 0/8/204 Corona, CA 92880 Telephone: 95-80-4665 Email: bmcdonald@amelect.com Fax: 95-552-626 Speedi Version: V 0.6 Valued Customer, Bill of Material

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

Evolution Series Switchboards

Evolution Series Switchboards GE Energy Evolution Series Switchboards Quick Reference imagination at work Main Lug Main Device Width (W) Switchboard Frame Neutral Bus Width (W) Switchboard Frame Neutral Bus Cover 3 A Ground Bar 10

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Power Mod. Standard Tapboxes.

Power Mod. Standard Tapboxes. Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Introduction. Upon completion of Basics of Meter Mounting Equipment

Introduction. Upon completion of Basics of Meter Mounting Equipment Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular

More information

Typical AEP Panelboard

Typical AEP Panelboard Typical AEP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Options. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE

Options. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE ADPA ADPA alid ADPA This marine-grade aluminum distribution panel is generally used for highways lighting control. It is a base This mount marine-grade design with aluminum the cables distribution entering

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

Typical ADP Panelboard

Typical ADP Panelboard Typical ADP Panelboard 400/600/800A Installation Consult instructions NEMA PB-1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE BC Hydro Metering Kiosk BCH Metering and distribution kiosk built to BC Hydro distribution standards. Used for applications where secondary services are installed in weatherproof kiosks outside of a main

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

10. METERING General Requirements

10. METERING General Requirements 10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

Australian Wiring Instructions:

Australian Wiring Instructions: Australian Wiring Instructions: Generator/Switch Wiring: Remove the generator controller fascia and identify wire #44 going to the circuit breaker in the external connection box, this wire is the active

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

Small Project Product Selection Guide

Small Project Product Selection Guide Small Project Product Selection Guide At your GE Distributor today! Panelboards Transformers Safety Switches NEMA Combo Starters Lighting Contactors imagination at work Small Projects Same Day When you

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary. GE Industrial Solutions EntellEon * Low-Voltage Power Panel Simple. Responsive. Revolutionary. Introducing EntellEon A More Versatile Alternative to Traditional Power Panels EntellEon, the new low-voltage

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

Introduction. Features. Intelligent Technologies Motor Control Center Structures

Introduction. Features. Intelligent Technologies Motor Control Center Structures Intelligent Technologies Technical Data New Information Description Page Intelligent Technologies General............................................. 2 s.......................................................

More information

Typical AE Panelboard

Typical AE Panelboard Typical AE Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Typical AD Panelboard

Typical AD Panelboard Typical AD Panelboard Installation Consult instructions NEMA PB-1.1 located in the circuit directory on the front door before installing this panelboard. If necessary, order replacement manual from supplier.

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

SynergEX Panelboards for Hazardous Locations

SynergEX Panelboards for Hazardous Locations SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /

More information

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SAFETY SOCKET BOX. Note 8 3 MIN. 3 Max. (200 A) .&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"

More information