5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Size: px
Start display at page:

Download "5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection"

Transcription

1 .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box MTBE = Main terminal box with utility pull box MCBE = Main circuit breaker with utility pull box 3 MTB 400 R C Bus Material C = Copper bus Blank= Aluminum bus Accessories and Additional Options BLK= Box lug kit (accessory) CLK= Compression lug (accessory) B = Bottom feed T = Top feed UG= Pull box Blank= No options Enclosure R = NEMA 3R Rating 400A 600A 800A 1000A 100A 1400A 1600A 000A When Ordering: 1. Determine catalog number of Main Service Module.. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T-1 or V1-T-13). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T-136 through V1-T-137. V1-T-10 Volume 1 Residential and Light Commercial CA E February 01

2 .11 Product Selection Main Terminal Box Phase and neutral lugs are included Top or bottom feed: For top feed, use Myer type hub Indoor or outdoor Terminal box UL listed short-circuit rating is the least AIC rating of any installed main tenant breaker to a maximum of 100,000 rms symmetrical amperes Main Terminal Box Main Terminal Box Rating Line Side Lug and Wire Sizes Included 10/40 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Aluminum Bus 400 (1) #6 600 or () 1/0 0 kcmil Use three-phase 3MTB400R 600 () 0 00 kcmil Use three-phase 3MTB600R 800 (4) 0 00 kcmil 1MTB800R 3MTB800R 100 (4) 0 00 kcmil 1MTB100R 3MTB100R Aluminum Bus (EUSERC) 400 Crimp lug landing pads (no lugs included) 1MTBE400R 3MTBE400R Notes 800 Crimp lug landing pads (no lugs included) 1MTBE800R 3MTBE800R Copper Bus 400 (1) #6 600 or () 1/0 0 kcmil Use three-phase 3MTB400RC 600 () 0 00 kcmil Use three-phase 3MTB600RC 800 (4) 0 00 kcmil 1MTB800RC 3MTB800RC 100 (4) 0 00 kcmil 1MTB100RC 3MTB100RC 1600 (6) 00 kcmil 1MTB1600RC 3MTB1600RC 100A main devices must be center fed when installing 800A residential meter stacks. 1600A main devices must be center fed when installing A residential and commercial meter stacks. For compression lug landing kits for 600A units, order 3MTB600CLK. Kit includes lug landings for three phases and neutral. For 800A units, to obtain (4) 1/0 300 kcmil or () 1/0 70 kcmil cables per phase order catalog number 3MTB800BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). For 100A units, to obtain (6) 1/0 300 kcmil or (3) 70 kcmil cables per phase order catalog number 3MTB100BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). For 800A and 100A units, for compression lug landing kits, order 3MTB100CLK. Kit includes lug landings for three-phase and neutral. Meets EUSERC electrical requirements and eliminates the need to add additional pull box section. For 1600A units, to obtain (4) 70 kcmil cables per phase order catalog number 3MTB1600BLK, one lug kit per main terminal box ordered. For a 1600A compression lug landing kit, order catalog number 3MTB1600CLK. Volume 1 Residential and Light Commercial CA E February 01 V1-T-103

3 .11 Main Circuit Breaker Phase and neutral lugs included. If additional neutral lugs are needed, order 1MCB100NLK for (3) 1/0 70 or (6) 1/0 300 kcmil For shunt trip mains, order the field-installable shunt trip kit in this volume, Tab 1, section 1.1 Main Circuit Breaker Notes For overhead feed, use Myer type hub. Verify local utility approval For compression lugs on 400, 600, 800, 1000 and 100A units, add CL to the end of the part number (includes copper lug pads for lines and neutral) 100A or greater main devices must be center fed when installing 800A residential meter stacks 1400, 1600 and 000A main devices must be center fed when installing 800 and 100A residential and commercial meter stacks Main Circuit Breaker Main Main Circuit 10/40 Vac Breaker Line Side Lug and Wire Sizes Single-Phase, Three-Wire Three-Phase, Four-Wire Rating Type Feed kaic (Lugs Included with Main Breaker) Aluminum Bus 0 KD Bottom 6 () 3/0 0 kcmil or (1) /0 00 kcmil 1MCB0R 3MCB0R 0 HKD Bottom 100 () 3/0 0 kcmil or (1) /0 00 kcmil 1MHCB0R 3MHCB0R 300 KD Bottom 6 () 3/0 0 kcmil or (1) /0 00 kcmil 1MCB300R 3MCB300R 300 HKD Bottom 100 () 3/0 0 kcmil or (1) /0 00 kcmil 1MHCB300R 3MHCB300R 30 KD Bottom 6 () 3/0 0 kcmil or (1) /0 00 kcmil 1MCB30R 3MCB30R 30 HKD Bottom 100 () 3/0 0 kcmil or (1) /0 00 kcmil 1MHCB30R 3MHCB30R 400 KD Bottom 6 () 3/0 0 kcmil or (1) /0 00 kcmil 1MCB400R 3MCB400R 400 HKD Bottom 100 () 3/0 0 kcmil or (1) /0 00 kcmil 1MHCB400R 3MHCB400R 00 LD Bottom 6 () kcmil 1MCB00R 3MCB00R 00 HLD Bottom 100 () kcmil 1MHCB00R 3MHCB00R 600 LD Bottom 6 () kcmil 1MCB600R 3MCB600R 600 HLD Bottom 100 () kcmil 1MHCB600R 3MHCB600R 700 HMDL Bottom 100 (3) 3/0 400 kcmil 1MHCB700R 3MHCB700R 700 MDL Bottom 6 (3) 3/0 400 kcmil 1MCB700R 3MCB700R 800 MDL Bottom 6 (3) 3/0 400 kcmil 1MCB800R 3MCB800R 800 MDL Bottom 6 () kcmil 1MCB800R70 3MCB800R HMDL Bottom 100 (3) 3/0 400 kcmil 1MHCB800R 3MHCB800R 900 ND Bottom 6 (4) 4/0 00 kcmil 1MCB900R 3MCB900R 900 HND Bottom 100 (4) 4/0 00 kcmil 1MHCB900R 3MHCB900R 1000 ND Bottom 6 (4) 4/0 00 kcmil 1MCB1000R 3MCB1000R 1000 ND Bottom 6 () kcmil 1MCB1000R70 3MCB1000R HND Bottom 100 (4) 4/0 00 kcmil 1MHCB1000R 3MHCB1000R 100 ND Bottom 6 (4) 4/0 00 kcmil 1MCB100R 3MCB100R 100 HND Bottom 100 (4) 4/0 00 kcmil 1MHCB100R 3MHCB100R 1400 RD Bottom 100 (4) kcmil 1MCB1400RBC 3MCB1400RBC 1400 RD Top 100 (4) kcmil 1MCB1400RT 3MCB1400RT 1600 RD Bottom 100 (4) kcmil 1MCB1600RBC 3MCB1600RBC 1600 RD Top 100 (4) kcmil 1MCB1600RT 3MCB1600RT 000 RD Bottom 100 (6) # 600 kcmil 1MCB000RBC 3MCB000RBC 000 RD Top 100 (6) # 600 kcmil 1MCB000RT 3MCB000RT If additional neutral lugs are needed, order 1MCB100NLK [(3) 1/0 70 kcmil or (6) 1/0 300 kcmil]. Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). If (3) kcmil are needed, order TA101NB1. Order one kit per pole. Main devices with a rating greater than 800A can be used with 800A residential modular stacks, but only as a center fed main. If (6) # 600 kcmil lugs are needed, order TA000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA000N. Copper bus. Main devices with a rating greater than 100A can be used with residential and commercial modular metering stacks but only as a center fed main. Only to be used in center feed applications with 100A meter stacks. Not to be used with 800A stacks. V1-T-104 Volume 1 Residential and Light Commercial CA E February 01

4 .11 Main Circuit Breaker Main Circuit Breaker Main Circuit Breaker, continued Main Main Circuit 10/40 Vac Breaker Line Side Lug and Wire Sizes Single-Phase, Three-Wire Three-Phase, Four-Wire Rating Type Feed kaic (Lugs Included with Main Breaker) Aluminum Bus (EUSERC Approved) 300 KD Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE300R 3MCBE300R 30 KD Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE30R 3MCBE30R 400 KD Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE400R 3MCBE400R 400 HKD Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE400R 3MHCBE400R 00 LD Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE00R 3MCBE00R 600 LD Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE600R 3MCBE600R 600 HLD Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE600R 3MHCBE600R 800 MDL Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE800R 3MCBE800R 800 HMDL Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE800R 3MHCBE800R 1000 ND Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE1000R 3MCBE1000R 100 ND Bottom 6 Crimp lug landing pads (no lugs included) 1MCBE100R 3MCBE100R 100 HND Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE100R 3MHCBE100R Copper Bus 400 KD Bottom 6 () 3/0 0 kcmil or (1) /0-00 kcmil 1MCB400RC 3MCB400RC 400 HKD Bottom 100 /0 00 kcmil 1MHCB400RC 3MHCB400RC 600 LD Bottom 6 () kcmil 1MCB600RC 3MCB600RC 600 HLD Bottom 100 () kcmil 1MHCB600RC 3MHCB600RC 800 MDL Bottom 6 (3) 3/0 400 kcmil 1MCB800RC 3MCB800RC 800 HMDL Bottom 100 (3) 3/0 400 kcmil 1MHCB800RC 3MHCB800RC 1000 ND Bottom 6 (4) 4/0 00 kcmil 1MCB1000RC 3MCB1000RC 1000 HND Bottom 100 (4) 4/0 00 kcmil 1MHCB1000RC 3MHCB1000RC 100 ND Bottom 6 (4) 4/0 00 kcmil 1MCB100RC 3MCB100RC 100 HND Bottom 100 (4) 4/0 00 kcmil 1MHCB100RC 3MHCB100RC Notes If additional neutral lugs are needed, order 1MCB100NLK [(3) 1/0 70 kcmil or (6) 1/0 300 kcmil]. Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). If (3) kcmil are needed, order TA101NB1. Order one kit per pole. Main devices with a rating greater than 800A can be used with 800A residential modular stacks but only as a center fed main. Volume 1 Residential and Light Commercial CA E February 01 V1-T-10

5 .11 Main Fusible Switches Fuses not included Main lugs and neutral included with device 100 kaic rating on switches with Class T fuses installed. If converting to Class H, the kaic rating is 10 and if converted to Class R, the kaic rating is 00 Note: This is the fuse rating, switch still rated at 100 kaic. Main Fusible Switches Main Fusible Switches Rating Feed Aluminum Bus Notes 800A top and bottom fed units are supplied with Class T fuse clips as standard. The Class T fuse clips are field convertible to Class L by repositioning. No kit is needed Barrier kits available for fusible switches: Bottom feed 3MFSBBK, Top feed 3MFSTBK Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) 10/40 Vac Single-Phase, Three-Wire If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS6FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS6FK kit will convert three poles. If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS66FK kit will convert three poles. Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral). If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral). IMFS100LK (3) 70 kcmil/phase (one kit/phase). IMFS100LKN (3) 70 kcmil (neutral). Three-Phase, Four-Wire 400 Bottom T () 1/0 300 kcmil or (1) 70 kcmil 1MFS400RB 3MFS400RB 400 Top T () 1/0 300 kcmil or (1) 70 kcmil 1MFS400RT 3MFS400RT 600 Bottom T () # 600 kcmil 1MFS600RB 3MFS600RB 600 Top T () # 600 kcmil 1MFS600RT 3MFS600RT 800 Bottom T (4) 3/0 70 kcmil 1MFS800RB 3MFS800RB 800 Top T (4) 3/0 70 kcmil 1MFS800RT 3MFS800RT 100 Bottom T (4) # 600 kcmil 1MFS100RB 3MFS100RB Copper Bus 400 Bottom T () 1/0 300 kcmil or (1) 70 kcmil 1MFS400RBC 3MFS400RBC 400 Top T () 1/0 300 kcmil or (1) 70 kcmil 1MFS400RTC 3MFS400RTC 600 Bottom T () # 600 kcmil 1MFS600RBC 3MFS600RBC 600 Top T () # 600 kcmil 1MFS600RTC 3MFS600RTC 800 Bottom T (4) 3/0 70 kcmil 1MFS800RBC 3MFS800RBC 800 Top T (4) 3/0 70 kcmil 1MFS800RTC 3MFS800RTC 100 Bottom T (4) # 600 kcmil 1MFS100RBC 3MFS100RBC V1-T-106 Volume 1 Residential and Light Commercial CA E February 01

6 .11 Main Fusible Switch with Utility Pull Box Fuses not included Includes lug landing pads on line side and neutral Spacer kit 3MMBSK required when stacks are mounted on right-hand side in EUSERC areas 100 kaic rating on switches with Class T fuse clips installed Main Fusible Switch with Utility Pull Box Utility Pull Box Includes lug landing pads on line side and neutral Requires cable connection in field to main device; does not include cross bus Pull Box Rating Feed Aluminum Bus Main Fusible Switch with Utility Pull Box Rating Feed Aluminum Bus Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) Note Pull box section includes landing studs for line side compression lugs. Wire sizes refer to fusible switch line side connection. 10/40 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire 400 Bottom T 1MFS400RUG 3MFS400RUG 600 Bottom T 1MFS600RUG 3MFS600RUG 800 Bottom T, L 1MFS800RUG 3MFS800RUG 100 Bottom T, L 1MFS100RUG 3MFS100RUG Copper Bus 400 Bottom T 1MFS400RUGC 3MFS400RUGC 600 Bottom T 1MFS600RUGC 3MFS600RUGC 800 Bottom T, L 1MFS800RUGC 3MFS800RUGC 100 Bottom T, L 1MFS100RUGC 3MFS100RUGC Line Side Lug Information Load Side Lug Information for Cable Connection to Main Disconnect 10/40 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire 400 Bottom 1/0 70 kcmil or () 1/0 300 kcmil 1UGPB400R 3UGPB400R 800 Bottom () 1/0 70 kcmil or (4) 1/0 300 kcmil 1UGPB800R 3UGPB800R 100 Bottom (4) # 600 kcmil 1UGPB100R 3UGPB100R Copper Bus 400 Bottom 1/0 70 kcmil or () 1/0 300 kcmil 1UGPB400RC 3UGPB400RC 800 Bottom () 1/0 70 kcmil or (4) 1/0 300 kcmil 1UGPB800RC 3UGPB800RC 100 Bottom (4) # 600 kcmil 1UGPB100RC 3UGPB100RC Volume 1 Residential and Light Commercial CA E February 01 V1-T-107

7 .11 Main Bolted Pressure Contact Switches Add suffix ST to catalog number for shunt trip Fuses not included 100 kaic rating on switches with Class L fuses installed Main Bolted Pressure Contact Switches 10/40 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Line Side Box Lugs and Wire Sizes (Included) Rating Feed Class Fuse Clips (Fuses Not Included) 100 Bottom L 1BPS100RB 3BPS100RB (6) #4 600 kcmil 100 Top L 1BPS100RT 3BPS100RT (6) #4 600 kcmil 1600 Bottom L Use three-phase 3BPS1600RB (6) #4 600 kcmil 1600 Top L Use three-phase 3BPS1600RT (6) #4 600 kcmil 000 Bottom L Use three-phase 3BPS000RB (6) #4 600 kcmil 000 Top L Use three-phase 3BPS000RT (6) #4 600 kcmil V1-T-108 Volume 1 Residential and Light Commercial CA E February 01

8 .11 Main Circuit Breaker with Busway Connection Verify proper left/right bus/main phasing. Note: Right means that the bus duct is to the right of the main and left means that the bus duct is to the left of the main. (See Dimension/ Layout section for clarification.) Main Circuit Breaker with Busway Connection Rating Feed Three-Phase, Four-Wire Internal Ground or Housing Ground Standard T or TO Opposite Phasing Right or Left Side 400 Bottom 3MFS400BCRGTO Internal TO Right 600 Bottom 3MFS600BCRGTO Internal TO Right 800 Bottom 3MFS800BCRGTO Internal TO Right 400 Bottom 3MFS400BCLGTO Internal TO Left 600 Bottom 3MFS600BCLGTO Internal TO Left 800 Bottom 3MFS800BCLGTO Internal TO Left 400 Bottom 3MFS400BCRGT Internal T Right 600 Bottom 3MFS600BCRGT Internal T Right 800 Bottom 3MFS800BCRGT Internal T Right 400 Bottom 3MFS400BCLGT Internal T Left 600 Bottom 3MFS600BCLGT Internal T Left 800 Bottom 3MFS800BCLGT Internal T Left 400 Bottom 3MFS400BCRNTO Housing TO Right 600 Bottom 3MFS600BCRNTO Housing TO Right 800 Bottom 3MFS800BCRNTO Housing TO Right 400 Bottom 3MFS400BCLNTO Housing TO Left 600 Bottom 3MFS600BCLNTO Housing TO Left 800 Bottom 3MFS800BCLNTO Housing TO Left 400 Bottom 3MFS400BCRNT Housing T Right 600 Bottom 3MFS600BCRNT Housing T Right 800 Bottom 3MFS800BCRNT Housing T Right 400 Bottom 3MFS400BCLNT Housing T Left 600 Bottom 3MFS600BCLNT Housing T Left 800 Bottom 3MFS800BCLNT Housing T Left 400 Bottom 3MCB400BCRGT Internal T Right 400 Bottom 3HMCB400BCRGT Internal T Right 600 Bottom 3MCB600BCRGT Internal T Right 600 Bottom 3HMCB600BCRGT Internal T Right 800 Bottom 3MCB800BCRGT Internal T Right 800 Bottom 3HMCB800BCRGT Internal T Right 1000 Bottom 3MCB1000BCRGT Internal T Right 1000 Bottom 3HMCB1000BCRGT Internal T Right 100 Bottom 3MCB100BCRGT Internal T Right 100 Bottom 3HMCB100BCRGT Internal T Right 400 Bottom 3MCB400BCLGT Internal T Left 400 Bottom 3HMCB400BCLGT Internal T Left 600 Bottom 3MCB600BCLGT Internal T Left 600 Bottom 3HMCB600BCLGT Internal T Left 800 Bottom 3MCB800BCLGT Internal T Left 800 Bottom 3HMCB800BCLGT Internal T Left 1000 Bottom 3MCB1000BCLGT Internal T Left 1000 Bottom 3HMCB1000BCLGT Internal T Left 100 Bottom 3MCB100BCLGT Internal T Left 100 Bottom 3HMCB100BCLGT Internal T Left 400 Bottom 3MCB400BCRNT Housing T Right 400 Bottom 3HMCB400BCRNT Housing T Right 600 Bottom 3MCB600BCRNT Housing T Right 600 Bottom 3HMCB600BCRNT Housing T Right 800 Bottom 3MCB800BCRNT Housing T Right 800 Bottom 3HMCB800BCRNT Housing T Right 1000 Bottom 3MBC1000BCRNT Housing T Right 1000 Bottom 3HMBC1000BCRNT Housing T Right Using this information, select the correct main device catalog number per the selection chart. Main Circuit Breaker with Busway Connection, continued Rating Feed Three-Phase, Four-Wire Internal Ground or Housing Ground Standard T or TO Opposite Phasing Right or Left Side 100 Bottom 3MCB100BCRNT Housing T Right 100 Bottom 3HMCB100BCRNT Housing T Right 400 Bottom 3MCB400BCLNT Housing T Left 400 Bottom 3HMCB400BCLNT Housing T Left 600 Bottom 3MCB600BCLNT Housing T Left 600 Bottom 3HMCB600BCLNT Housing T Left 800 Bottom 3MCB800BCLNT Housing T Left 800 Bottom 3HMCB800BCLNT Housing T Left 1000 Bottom 3MCB1000BCLNT Housing T Left 1000 Bottom 3HMCB1000BCLNT Housing T Left 100 Bottom 3MCB100BCLNT Housing T Left 100 Bottom 3HMCB100BCLNT Housing T Left 400 Bottom 3MCB400BCRGTO Internal TO Right 400 Bottom 3HMCB400BCRGTO Internal TO Right 600 Bottom 3MCB600BCRGTO Internal TO Right 600 Bottom 3HMCB600BCRGTO Internal TO Right 800 Bottom 3MCB800BCRGTO Internal TO Right 800 Bottom 3HMCB800BCRGTO Internal TO Right 1000 Bottom 3MCB1000BCRGTO Internal TO Right 1000 Bottom 3HMCB1000BCRGTO Internal TO Right 100 Bottom 3MCB100BCRGTO Internal TO Right 100 Bottom 3HMCB100BCRGTO Internal TO Right 400 Bottom 3MCB400BCLGTO Internal TO Left 400 Bottom 3HMCB400BCLGTO Internal TO Left 600 Bottom 3MCB600BCLGTO Internal TO Left 600 Bottom 3HMCB600BCLGTO Internal TO Left 800 Bottom 3MCB800BCLGTO Internal TO Left 800 Bottom 3HMCB800BCLGTO Internal TO Left 1000 Bottom 3MCB1000BCLGTO Internal TO Left 1000 Bottom 3HMCB1000BCLGTO Internal TO Left 100 Bottom 3MCB100BCLGTO Internal TO Left 100 Bottom 3HMCB100BCLGTO Internal TO Left 400 Bottom 3MCB400BCRNTO Housing TO Right 400 Bottom 3HMCB400BCRNTO Housing TO Right 600 Bottom 3MCB600BCRNTO Housing TO Right 600 Bottom 3HMCB600BCRNTO Housing TO Right 800 Bottom 3MCB800BCRNTO Housing TO Right 800 Bottom 3HMCB800BCRNTO Housing TO Right 1000 Bottom 3MCB1000BCRNTO Housing TO Right 1000 Bottom 3HMCB1000BCRNTO Housing TO Right 100 Bottom 3MCB100BCRNTO Housing TO Right 100 Bottom 3HMCB100BCRNTO Housing TO Right 400 Bottom 3MCB400BCLNTO Housing TO Left 400 Bottom 3HMCB400BCLNTO Housing TO Left 600 Bottom 3MCB600BCLNTO Housing TO Left 600 Bottom 3HMCB600BCLNTO Housing TO Left 800 Bottom 3HMCB800BCLNTO Housing TO Left 800 Bottom 3HMCB800BCLNTO Housing TO Left 1000 Bottom 3MCB1000BCLNTO Housing TO Left 1000 Bottom 3HMCB1000BCLNTO Housing TO Left 100 Bottom 3MCB100BCLNTO Housing TO Left 100 Bottom 3HMCB100BCLNTO Housing TO Left Volume 1 Residential and Light Commercial CA E February 01 V1-T-109

9 .11 Dimensions Approximate Dimensions in Inches (mm) Dimensions (Not to be Used for Construction Purposes) Main Device Terminal Box Width Height Depth Mounting Center Line of Wall Mounting Bracket Knockouts in Bottom Endwalls Except No KOs for Top Feed Switch or Bolted Pressure Switch Conduit Diameter A B C D E F Inches mm 400 and 600A 13.0 (34.9) 48.7 (138.3) 7.00 (177.8) 4.00 (1371.6) (777.9) (1).0, 3.00, 3.0, 4.00 (1) and 100A 0.00 (08.0) (109.8) 11.7 (98.) 1.00 (304.8) 1.0 (1308.1) (777.9) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, A 3.88 (83.) (17.3) (90.6) (406.4) (168.9) 38.9 (980.) (1) 0.7, 1.00, 1., 1.0 () 3.00, 3.0, 4.00,.00 Main Circuit Breaker with Box Lugs A 0.00 (08.0) (109.8) 11.7 (98.) 1.00 (304.8) 1.0 (1308.1) (777.9) () 0.0, 0.7, 1.00 (4).00,.0, 3.00,3.0, 4.00 (1) 63., 76., 88.9, (1) 1.7 () 1.1, 19.1,.4 (4) 0.8, 63., 76., 88.9, (1) 19.1,.4, 31.8, 38.1 () 76., 88.9, 101.6, 17.0 () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, A 4.88 (63.0) 7.13 (141.0) (378.0) (406.4) 7.13 (141.0) (1117.6) Main Circuit Breaker with Compression Lugs A 0.00 (08.0) (149.4) 11.7 (98.) 1.00 (304.8) 6.00 (161.0) (1117.6) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, 4.00 Main Fusible Switch Bottom feed A Top feed A 0.00 (08.0) (109.8) 11.7 (98.) 1.00 (304.8) 1.0 (1308.1) (777.9) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, (08.0) (109.8) 11.7 (98.) 1.00 (304.8) 1.0 (1308.1) (460.4) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, A 33.0 (80.9).7 (1339.9) (301.8) (406.4) 6. (148.8) 30.7 (781.1) () 3.0, 4.00,.00 (1) 0.7, 1.00, 1., 1.0 Bolted Pressure Switch () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 88.9, 101.6, 17.0 (1) 19.1,.4, 31.8, (97.1) 66.0 (1689.1) 19.0 (49.3) 8.00 (711.) (14.0) (777.9) Main Fusible Switch with Pull Box 400A 0.00 (08.0) (149.4) 11.7 (98.) 1.00 (304.8) 6.00 (161.0) (1117.6) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, and 800A (single-phase) 600 and 800A (three-phase) 0.00 (08.0) (149.4) 11.7 (98.) 1.00 (304.8) 6.00 (161.0) (1117.6) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, (636.) (149.4) 11.7 (98.) (431.8) 6.00 (161.0) (1117.6) () 0.0, 0.7, 1.00 (4).00,.0, 3.00, 3.0, A 33.0 (80.9) 61.0 (16.1) (301.8) (406.4) 6. (167.4) (119.) () 3.0, 4.00,.00 (1) 0.7, 1.00, 1., 1.0 Main Circuit Breaker with Pull Box (EUSERC) () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 1.7, 19.1,.4 (4) 0.8, 63., 76., 88.9, () 88.9, 101.6, 17.0 (1) 19.1,.4, 31.8, A 0.01 (08.) (13.) (83.0) 1.00 (304.8) 6.11 (163.8) 39.7 (1009.6) (4).0, 3.00, 3.0, 4.00 (4) 63., 76., 88.9, A 4.88 (63.0) (147.9) (83.0) (431.8) (1648.0) (1011.) (4).0, 3.00, 3.0, 4.00 (4) 63., 76., 88.9, A (838.) (13.0) 11.3 (87.) (406.4) 6. (167.4) 43.6 (1106.4) (4).0, 3.00, 3.0, 4.00 (4) 63., 76., 88.9, Pull Box 400A (416.1) (1140.0) 7.88 (00.) 8.00 (03.) 4.7 (116.1) 8.63 (77.) () A 4.38 (619.3) (1190.8) (301.8) 1.00 (304.8) 47.7 (11.9) 3. (819.) (3) A 3.0 (8.) 6.88 (1444.8) 1.00 (304.8) 17.7 (40.9) 7.7 (1466.9) 4. (1073.) (4) EUSERC Bussed Pull Section Single-phase 400 and 800A 0.13 (11.3) (149.4) 11. (8.8) 1.00 (304.8) (1648.0) (1117.6) (4).0, 3.00, 3.0, 4.00 (4) 63., 76., 88.9, Three-phase 400 and 800A EUSERC Main Terminal Box Single-phase 400 and 800A Three-phase 400A Three-phase 800A.13 (638.3) (149.4) (301.8) (431.8) (1648.0) (1117.6) (4).0, 3.00, 3.0, 4.00 (4) 63., 76., 88.9, (11.3) (149.4) (301.8) 1.00 (304.8) (1648.0) (1117.6) () 0.0, 0.7, 1.00 () 1.7, 19.1, (11.3) (149.4) (301.8) 1.00 (304.8) (1648.0) (1117.6) (4).00,.0, 3.00, 3.0, 4.00 (4) 0.8, 63., 76., 88.9, (638.3) (149.4) (301.8) (431.8) (1648.0) (1117.6) (4).00,.0, 3.00, 3.0, 4.00 (4) 0.8, 63., 76., 88.9, KO Dwg V1-T-110 Volume 1 Residential and Light Commercial CA E February 01

10 .11 Approximate Dimensions in Inches (mm) Main Circuit Breakers, Terminal Boxes and Pull Boxes A Bolted Pressure Switch A C E B F E B F D Main CB, Non-Euserc Terminal Box and Pullboxes Top Feed Fusible Switch A C C D EUSERC Main Terminal Box A C.00 (63.0) E B B F D (431.8) Top Feed Switch (No Knockouts) Bottom Feed Fusible Switch and Combination Fusible Switch with Pull Box A C E B F D (431.8) Bottom Feed Switch and Combination Switch/Pullbox Volume 1 Residential and Light Commercial CA E February 01 V1-T-111

11 .11 Approximate Dimensions in Inches (mm) Knockout Outside KO (44) Knockout.4 Knockout 3 Knockout 4 1/ Knockout -1/, 3, 3-1/, 4 KO 1 Required 1 Knockout Required Per Diameter.00 Paint Hole Knockouts for 1/, 3/4 or 1 Conduit.81 Diameter Knockout 1 Required 4 Knockouts for -1/, 3, 3-1/ or 4 Conduit A KO (1) , 3-1/, 4, Knockout Per A0-637 Knockouts Required Knockouts for 1/, 3/4 or 1 Conduit.81 Diameter Knockout 1 Required 4 Knockouts for -1/, 3, 3-1/ or 4 Conduit B C L Stamped ID Mark Diameter Hole /4, 1, 1-1/4, 1-1/ Knockout Per A Knockout Required Diameter Holes Required at X Knockout Knockout 6.0 Ref Knockout Ref Knockout 8 KO (10).0 Dia..0 Paint Ref. Hole.1.0 Dia. Paint Hole KO (10).30 Ref. KO (11) Dia. Knockout 1 Required Knockouts for 1/", 3/4", or 1" Conduit Knockouts for 1/", 3/4", or 1" Conduit KO (10) KO (11) KO (10) KO (10) KO (11) KO (11) Knockouts for -1/", 3", 3-1/" or 4" Conduit V1-T-11 Volume 1 Residential and Light Commercial CA E February 01

12 Volume 1 Residential and Light Commercial CA E February 01 V1-T Approximate Dimensions in Inches (mm) Layout Main Fusible Switch

13 .11 Approximate Dimensions in Inches (mm) Main Circuit Breaker Phasing Right Wall (984.) Meter Center Front (461.) 0.00 (08.0) Floor 6.00 (1.4) C L Horizontal (764.0) Main Circuit Breaker Phasing Left 8.48 Wall (1.4) C L Vertical (764.0) 6.00 (1.4) (984.) Meter Center Front 0.00 (08.0) Floor (461.) 8.48 (1.4) C L Vertical C L Horizontal Main Circuit Breaker Standard T Phasing Right Wall Meter Center Front (984.) (461.) 0.00 (08.0) Floor 6.00 (1.4) C L Horizontal (764.0) Main Circuit Breaker Standard T Phasing Left 8.48 (1.4) Wall C L Vertical (764.0) 6.00 (1.4) (984.) Meter Center Front (461.) 0.00 (08.0) Floor 8.48 (1.4) C L Vertical C L Horizontal V1-T-114 Volume 1 Residential and Light Commercial CA E February 01

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .11 Metering Products Systems for Residential and Commercial Application Systems for Residential and Commercial Applications Product Description Group metering is a service entrance product line that consists

More information

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering Contents Description Systems for Residential and Commercial pplications............................ Meter Packs............................. Type CCV 0/0 V Tenant Main Circuit reaker Type CV 0/0 V Tenant

More information

Meter Centers & Loadcenters Group Metering

Meter Centers & Loadcenters Group Metering June 006 Sheet 1015 5MM, 7MM, 5SS and 7SS Main Circuit s The following breakers are to be used on 5MM, 7MM, 5SS and 7SS modular metering stacks. Series rating information available on Pages 6.1-8 through

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................

More information

Group Meter Main - Without Bypass

Group Meter Main - Without Bypass 100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included

More information

Group Metering & Meter Breakers. Group Metering & Meter Breakers 5-1. Contents

Group Metering & Meter Breakers. Group Metering & Meter Breakers 5-1. Contents Group Metering & Meter reakers - July Group Metering & Meter reakers Contents Description Page Single Meter Sockets............................................ - Group Metering.................................................

More information

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB Panelboards and Lighting Control Metering Service Sections.7 Metering Service Section Contents Description Metering Service Sections Page Catalog Number Selection........................ 482 Product Selection..............................

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Meter Mains - Without Bypass

Meter Mains - Without Bypass - 100 & 200 Amp Application Single meter position Receive ANSI C12.10 watthour meters Surface or flush mount (see chart) 1M1R (closed) U2M2R (open) Construction Ring type NEMA Type 3R ANSI 61 gray E-coat

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Low Voltage Busway Features, Benefits and Functions Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal

More information

Power Mod. Introduction.

Power Mod. Introduction. Power Mod Siemens is proud to introduce Power Mod with QuickSystem - a new robust and featurerich line of modular metering designed with the contractor in mind. Power Mod features a unique combination

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

CURRENT TRANSFORMER METERING (TRANSOCKETS) WITH OVERHEAD SERVICE ENTRANCE

CURRENT TRANSFORMER METERING (TRANSOCKETS) WITH OVERHEAD SERVICE ENTRANCE 4, 5 & 7-TERMINAL MODULAR METERING UNITS 1Ø 3-Wire 120/240 or s 0-200 s per position M-22 3Ø 3-Wire 240 Volts or 480 Volts (Ungrounded) 0-200 s per position M-22 3Ø 4-Wire 208Y/120 or s 0-200 s per position

More information

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application - and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are

More information

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application - and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS

More information

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Class 320 Metering. Class 320 Metering. Meter Mounting Equipment Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -..........

More information

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Multiple Metering, Horizontal Gang - Non Lever Bypass

Multiple Metering, Horizontal Gang - Non Lever Bypass Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families

Modular Metering Stock Selection Guide. Meter Mod * III and Mini Mod * III Product Families Modular Metering Stock Selection Guide Meter Mod * III and Mini Mod * III Product Families Table of Contents Page No. Nomenclature 3 Main Breaker Module, Single-Phase, 3 Wire, 0/40 Vac 4 Main Breaker Module,

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Multiple Metering, Vertical Gang

Multiple Metering, Vertical Gang Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

5.11. Metering Products. Contents Description Systems for Residential and Commercial

5.11. Metering Products. Contents Description Systems for Residential and Commercial 3MM, 37MM, 3SS and 37SS Main Tenant ircuit reakers V2/EHD2100 ontents Description Systems for Residential and ommercial pplications............................ Meter Packs.............................

More information

Metering NEED. Meter Sockets. Product Description

Metering NEED. Meter Sockets. Product Description Meter Sockets Meter Sockets Single Position (Ring, Ringless and Bypass)........ - Multiple Position Without Tenant Main Breakers.......... - Accessories.......................... -7 Meter Packs (All-in-Ones)

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits.

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits. Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water

More information

6.1 Introduction Product Description... Application Description... Optional Features...

6.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................

More information

Section 6 Electric Metering: Residential

Section 6 Electric Metering: Residential Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features... Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................

More information

EOEM panelboard and switchboard (OPS) Program

EOEM panelboard and switchboard (OPS) Program Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Volume 1 Residential and Light Commercial CA E December

Volume 1 Residential and Light Commercial CA E December Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

PROJECT MANAGEMENT Transmittal No 17D

PROJECT MANAGEMENT Transmittal No 17D GH Phipps Construction Co. 5995 Greenwood Plaza Blvd. Suite 00 Greenwood Village CO 80-470 PROJECT MANAGEMENT Transmittal No 7D5780-00 PROJECT: Thistle-Valmont Square Interior & Exterior Renovation DATE:

More information

Modular Metering Construction Details

Modular Metering Construction Details GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single

More information

Air Conditioning Disconnects

Air Conditioning Disconnects .1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................

More information

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SAFETY SOCKET BOX. Note 8 3 MIN. 3 Max. (200 A) .&. SAFETY SOCKET BOX USE: 1 12/24V 1A & 2A 4 Terminal EUSERC Dwg. No's 34 & 35 (With Factory Installed Test-Bypass Facilities) Refer to SR-452 for the complete Front View Lower-Panel Removed Note 3 3"

More information

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2 Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................

More information

Introduction. Features. Intelligent Technologies Motor Control Center Structures

Introduction. Features. Intelligent Technologies Motor Control Center Structures Intelligent Technologies Technical Data New Information Description Page Intelligent Technologies General............................................. 2 s.......................................................

More information

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets .1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

Power Mod. Standard Tapboxes.

Power Mod. Standard Tapboxes. Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility:

More information

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard... .6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.

More information

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and

More information

Panelboards. Panelboards Contents

Panelboards. Panelboards Contents -1 February 7 Contents Description Page EZ Box and EZ Trim.............................................. -2 Product Selection............................................... -4 Product Description.............................................

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and

More information

REC Municipal Meter Mounting Equipment

REC Municipal Meter Mounting Equipment REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

Single Socket and Horizontal Metering

Single Socket and Horizontal Metering Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

Busway Products Medium Voltage Busway Nonsegregated Phase Bus

Busway Products Medium Voltage Busway Nonsegregated Phase Bus Busway Products Pow-R-Way III Upward Elbow.1 Pow-R-Way III Busway Product Description........................................... 2 Features, Benefits and Functions................................ 12 Standards

More information

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards Panelboards Solar Applications.7 Contents Description Introduction.............................. Product Selection Guide.................. EZ Box and EZ Trim........................ Type PRL1a...........................

More information