2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information
|
|
- Griffin Patrick
- 6 years ago
- Views:
Transcription
1 Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. Except as noted, terminals comply with Underwriters Laboratories Standards UL 486A and UL 486B. Unless otherwise specified, F- circuit breakers are factory equipped with load terminals only. Amperes Terminal Body Material Ordering Information F- circuit breakers and molded case switches have load terminals only as standard equipment. When standard line-end terminals (same as standard load-end terminals) are required, add Suffix L to the circuit breaker catalog number. When nonstandard or optional line and/ or load terminals are required, order by style number. Specify if factory installation is required. Wire AWG Wire mm Package of Three Terminals Standard Pressure Terminals 0 (EHD) Steel Cu/AI T0FB 100 Steel Cu/AI 14 1/ T100FB 5 Aluminum Cu/AI 4 4/ TA5FD Optional Pressure Terminals 50 Aluminum Cu/AI TA50FB 100 Aluminum Cu/AI 14 1/ TA100FD 00 Stainless steel Cu 4 4/ T150FB 5 Copper Cu 4 4/ T5FD 5 Aluminum Cu/AI kcmil TA5FDK3 3 5 Aluminum Cu/AI kcmil TA5FDK Use on FDE, HFDE and FDCE electronic trip only. Not for use with ED, EDH, EDC breakers. 3 Includes terminal shield kit. Adds approximately 3 inches (76.) to breaker height. Available for use on three-pole breaker only. 4 Replacement use only. Volume 4 Circuit Protection CA E August V4-T-147
2 .3 Molded Case Circuit s Series C Washer Wire Clamp 3T0FB 3T100FB, 3T150FB 3TA5FD Assemble wire clamp to bottom of conductor as shown. Insert collar enclosing conductor as shown. Locate nut on top of conductor and tighten securely with screw and washer. Caution: must surround conductor. Washer Washer 3TA50FB 3TA100FD 3TA5FDK3 (Up to 150 mm ) Assemble collar on top of conductor as shown. Tighten securely with screw and washer. Nut slides onto conductor and is held in position by a screw and lockwasher. Extrusion Clip Insert collar enclosing conductor and center on extrusion on collar. Install clip with legs on top of conductor and snap end around bottom of collar. Assemble collar on top of conductor as shown. Tighten securely with screw and washer. Terminal shield must be used with this collar. Note: For 185 mm, use 3TA5FDK1. Same illustration for 3TA5FDK V4-T-148 Volume 4 Circuit Protection CA E August 016
3 Molded Case Circuit s Series C.3 Product Selection FD Series C High Performance Ratings Product Amperes 480 Vac (UL) 600 Vac (UL) FDC 3P thermal-magnetic only With limiter FD IC Rating 00 kaic at 600 Vac 1 Ampere Rating Limiter Terminals Amperes Load Terminals (For Line Mounted Limiters Only) with Line Side Mounted Current Limiter 1 Line and load terminal included. Two interphase barriers provided, mounted on line end of limiter, catalog number FJ1PBK. 3 Four interphase barriers provided, () line end of breaker, () load end of limiter. 4 Load side breaker terminations included for units configured with line mounted limiters. with Load Side Mounted Current Limiter 3 Thermal-Magnetic 40 FDC3040Q01 FDC3040YQ0 45 FDC3045Q01 FDC3045YQ0 50 FDC3050Q01 FDC3050YQ0 60 FDC3060Q01 FDC3060YQ0 70 FDC3070Q01 FDC3070YQ0 80 FDC3080Q01 FDC3080YQ0 90 FDC3090Q01 FDC3090YQ0 100 FDC3100Q01 FDC3100YQ0 110 FDC3110Q01 FDC3110YQ0 15 FDC315Q01 FDC315YQ0 150 FDC3150Q01 FDC3150YQ0 175 FDC3175Q01 FDC3175YQ0 00 FDC300Q01 FDC300YQ0 Terminal Body Material Wire mm AWG Wire / of s Standard Pressure Terminals 50 Aluminum Cu/Al #8 350 (1) TA50FJ 4 Amperes Terminal Body Material Wire AWG Wire mm Package of Three Terminals Standard Pressure Terminals 100 Steel Cu/AI 14 1/ T100FB 5 Aluminum Cu/AI 4 4/ TA5FD Volume 4 Circuit Protection CA E August V4-T-71
4 .4 Molded Case Circuit s Definite Purpose Features Base Mounting Hardware English base mounting hardware is included with GP frame only. For all other frames, order base mounting hardware separately as per the table to the right. Both line and load terminals are included with GP- Definite Purpose breakers. For all other frames, add L for line and load terminals to be included or W for no terminals. Accessories End Cap Accessory Kit End caps for line and load conductor termination are optional with each breaker. End caps secure the conductor with a ring-type connector. The kit includes one end cap, three cap screws, three nuts and three lock washers. Series C Accessories For internal accessories, see Page V4-T-73. For external accessories, see Page V4-T-304. Base Mounting Hardware English Metric GP Included FP BMH1 BMH1M KP BMH3 BMH3M LP BMH4 BMH4M MP BMH5 BMH5M Note: Base mounting hardware, is included with GP- breakers. A separate catalog number is not required. Line and Load Termination Optional Termination 1 Package of three terminals. Replacement use only. End Cap Accessory Kit Awg Wire (mm) Wire Bolt Size English Bolt Size Metric Torque Lb In Torque Nm GP Wire #14 1/ Cu only Included Amperes Awg Wire Wire with Control Wire Termination FP 100 #14 #10 Cu/Al 3T100FB #8 Cu/Al 3T100FB #6 #4 Cu/Al 3T100FB #3 4/0 Cu/Al 3T100FB 1 00 #3 4/0 Cu only 3T150FB 1 5 #4 4/0 Cu/Al 3TA5FB 1 5 #6 300 Cu/Al 3TA5FDK3 1 5 #6 300 Cu/Al 3TA5FDK 1 KP (1) Cu/Al TA350K 400 3/0 50 () Cu/Al 3TA400K 1 3TA400KCW LP () Cu/Al TA60LD TA60LDCW () Cu/Al 3TA603LDK 1 3TA603LDKCW MP 800 3/0 400 (3) Cu/Al TA800MA TA800MACWT () Cu/Al TA801MA TA801MACWT V4-T-334 Volume 4 Circuit Protection CA E August 016
5 Molded Case Circuit s Specialty s.6 Accessories Selection Guide and Ordering Information Enclosures 1 General Purpose Surface or flush mounting ampere range 600 Vac, 500 Vdc 1 enclosed breakers are designed for use in commercial buildings, apartment buildings and other areas where a general purpose enclosure is applicable. The breaker is front operable and is capable of being padlocked in either the ON or OFF position. Ratings through 100 amperes are listed with Underwriters Laboratories as approved for service entrance application. Both surface and flush mounted enclosures are available. 3R Rainproof Surface Mounting Interchangeable hubs (through 400 amperes) ampere range 600 Vac, 500 Vdc This general purpose outdoor service center employs a circuit breaker inside a weatherproof sheet steel breaker enclosure to serve Enclosure Selection Data Amperes FG 15 5 JG KG LG NG Enclosure Class 1 3R 1 1 3R 1 1 3R 1 1 3R 1 1 3R 1 as a main disconnect and protective device for feeder circuits. Ratings through 100 amperes are listed by Underwriters Laboratories as suitable for service entrance application. 1 Dustproof Surface Mounting No knockouts or other openings ampere range 600 Vac, 500 Vdc The 1 enclosure is designed in line with specifications for special industry applications where unusually severe conditions involving oil, coolant, dust and other foreign materials exist in the operating atmosphere. The handle padlocks in the OFF position and the cover is interlocked with the handle mechanism to prevent opening the cover with the circuit breaker in the ON position. Ratings through 100 amperes are listed by Underwriters Laboratories as suitable for service entrance application. SFDN5 RFDN5 JFDN5 SJDN50 RJDN50 JJDN50 SKDN400 RKDN400 JKDN400 SLDN600 RLDN600 JLDN600 SNDN100 RNDN100 JNDN100 Options and Accessories Standard Terminals Max. Amp Rating Neutral Kits, Insulated and Groundable Internal Accessories Auxiliary Switch AWG Wire mm FG / T100FB 1 FG / TA5FD 1 JG kcmil TA50KB KG kcmil TA350K KG 400 3/0 50 kcmil () TA400K 1 LG kcmil () TA603LDK NG kcmil () TA700NB1 NG /0 400 kcmil (3) TA1000NB1 NG 100 4/0 500 kcmil (4) TA100NB1 Max. Enclosure Rating (Amperes) Main Lug Size Cu/Al Ground Lug Size Cu/Al 100 (1) 14 1/0 (1) 14 1/0 INK (1) kcmil (1) kcmil INK (1) kcmil or (1) kcmil INK400 () 1/0 50 kcmil 600 () kcmil (1) kcmil INK (3) 1/0 to 750 kcmil or (4) 1/0 to 750 kcmil Factory Mounted 1A-1B Field Kit (1) 6 50 kcmil INK100 Factory Mounted A-B Field Kit FG 3 A06 A1X1PK A13 AX1RPK JG A06 A1XPK A13 AXPK KG A06 A1X3PK A13 AX3PK LG A06 A1X4PK A13 AX4PK NG A06 A1X5PK A13 AX5PK Shunt Trip Factory Field Kit Rating Mounted FG Vdc S0 SNT1LP03K JG 1 4 Vdc S4 SNTP04K KG 1 4 Vdc S4 SNT3P04K LG 1 4 Vdc S0 SNT4LP03K NG 1 4 Vdc S0 SNT5LP03K 1 Package of three terminals. Other accessories are available. Same as standard frame breakers. 3 Field installation on the FG is not UL listed. Volume 4 Circuit Protection CA E August V4-T-345
6 .6 Molded Case Circuit s Specialty s DC Terminal Wire s Ampacity Note: RGHDC breakers include six rear connectors as standard. Molded Case Switches Eaton s DC molded case switches are used in applications requiring a compact, high-capacity disconnect. They are UL 489 listed and have automatic high instantaneous current protection. These devices do not provide overload protection. Molded Case Switches Note 1 Four-pole frame with two-pole connected in parallel. Terminal Body Material Wire AWG Wire / of s mm of Terminals Included Standard Terminal EGEDC, EGSDC, EGHDC 100 Aluminum Cu/Al 14 1/ TA15EF HFDDC 0 Steel Cu/Al (1).5 4 (1) 3 3T0FB 100 Steel Cu/Al 14 1/0 (1).5 50 (1) 3 3T100FB 5 Aluminum Cu/Al 4 4/0 (1) 5 95 (1) 3 3TA5FD JGEDC, JGSDC, JGHDC 50 Stainless steel Cu (1) (1) 1 T50FJ HJDDC 50 Aluminum Cu/Al kcmil (1) (1) 1 TA50KB HKDDC 5 Aluminum Cu/Al kcmil (1) (1) 1 TA300K 350 Aluminum Cu/Al kcmil (1) (1) 1 TA350K 400 Aluminum Cu/Al 3/0 50 kcmil () (1) 3 3TA400K LGEDC, LGSDC, LGHDC 400 Aluminum Cu/Al 500 (1) (1) 1 TA350LK 630 Aluminum Cu/Al 500 kcmil () () 1 TA63L 630 Aluminum Cu/Al 500 kcmil () () 3 3TA63LK HLDDC 500 Aluminum Cu/Al 3/0 350 kcmil () () 1 TA60LD 600 Aluminum Cu/Al kcmil () () 3 3TA603LDK HMDLDC 600 Aluminum Cu/Al kcmil () 1 TA700MA1 800 Aluminum Cu/Al 3/0 400 kcmil (3) 1 TA800MA NBDC 700 Aluminum Cu/Al 3/0 400 kcmil (3) (3) 1 TA1000NB1 800 Aluminum Cu/Al 3/0 400 kcmil (3) (3) 1 TA1000NB1 900 Aluminum Cu/Al 3/0 400 kcmil (3) (3) 1 TA1000NB Aluminum Cu/Al 3/0 400 kcmil (3) (3) 1 TA1000NB1 100 Aluminum Cu/Al 4/0 500 kcmil (4) (4) 1 TA100NB1 Continuous Ampere Rating at 40 C Interrupting Capacity (Volts DC) Poles in Series With Without 600 Vdc HFDDC3100KL HFDDC3100KW HFDDC3150KL HFDDC3150KW HFDDC35KL HFDDC35KW JGKDC350KSG JGKDC350KSW HJDDC350K HJDDC350KW HKDDC3400K HKDDC3400KW 65 3 LGKDC3400KSG LGKDC3400KSW LGKDC3630KSG LGKDC3630KSW 35 3 HLDDC3600K HLDDC3600WK HMDLDC3800K HMDLDC3800WK 500 Vdc EGK3100KSG EGK3100KSW 50 Vdc HFDDC100KL HFDDC100KW HFDDC150KL HFDDC150KW 5 50 HFDDC5KL HFDDC5KW HLDDC100K 1 HLDDC100WK 1 V4-T-356 Volume 4 Circuit Protection CA E August 016
7 Molded Case Circuit s Specialty s.6 Accessories Amperes End Cap Terminals For Use with Ring Terminals External Accessories Padlockable Handle Lock Hasp Wire AWG Wire (No. s) E F/E FM 100 Cu/AI #14 1/0 (1) 3T100FB (package of three) 150 Cu #4 4/0 (1) 3T150FB (package of three) E J/E JM 50 Cu #4 350 (1) T50KB E K/E KM/E KW 5 Cu #3 350 (1) T300K 350 Cu (1) T350K 400 Cu /0 50 () 3T400K (three-pole kit) E LME/E LMZ 400 Cu/AI (1) 3TA631LK E L/E LM/E LW 400 Cu/AI 4/0 600 (1) 3TA401LDK (three-pole kit) 600 Cu () T60LD E M/E MM/E MW 600 Cu () /0 500 kcmil T600MA1 600 Cu/AI () kcmil TA700MA1 800 std. Cu/AI (3) 3/0 400 kcmil TA800MA 800 Cu/AI () kcmil TA801MA 800 Cu (3) 3/0 300 kcmil T800MA1 E N/E NM 700 Cu /0 500 () T700NB Cu 3/0 500 (3) T1000NB1 100 Cu 3/0 400 (4) T100NB Cu/AI (4) TA1600RD 000 Cu/AI 600 (6) TA000RD Amperes Metric E F/E FM 150 KPEK1 KPEMK1 E J/E JM 50 KPEK KPEMK E K/E KM/E KW 400 KPEK3 KPEMK3 E LME/E LMZ 400 L3RTWK E L/E LM/E LW 600 KPEK4 KPEMK4 E F/E FM E J/E JM E K/E KM/E KW E LME/E LMZ E L/E LM/E LW E M/E MM/E MW E N/E NM E R/E RM PLK1 PLK3 PLK3 LPHL HLK4 HLK4 PLK5 HLK6 Imperial Volume 4 Circuit Protection CA E August V4-T-391
2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description
Molded Case Circuit s Series C.3 Series C Internal Accessories Contents Description Product Overview.......................... Standards and Certifications.................. Quick Reference...........................
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More information25.5. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.5 Molded Case Circuit Breakers Engine Generator Circuit Breakers Contents Description Engine Generator Circuit Breakers Selection................ Product Selection....................... Accessories Selection
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More information2.3. Molded Case Circuit Breakers. Contents
.3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by
More informationInterrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F
-220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000
More information2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationSwitchboards Instant Service
January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8
More informationTechnical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs
-14 1 Amperes November 08 Eaton s Cutler-Hammer EG Product Description EG breaker is HACR rated. Technical Data and Specifications Table -6. UL 489/IEC 947-2 Interrupting Capacity Ratings Circuit Interrupting
More informationTable Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationL-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W
July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
More informationMolded Case. Circuit Breakers. Molded Case Circuit Breakers Contents
January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationApplications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim
Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationCutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed
More informationPanelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description
.5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,
More informationPVGard 600 and 1000 Vdc solar photovoltaic circuit breakers
Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Series G Circuit Breakers.1 Introduction Product Overview......................................... V4-T- Typical Applications........................................ V4-T-
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationF-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:
-0 Motor ircuit Protectors Vol. 1, Ref. No. [058] -rame Table -188. V A, V NMA Starter Size ont. Amps am Motor ull Load urrent Amps MP Trip MP Table -188. V A, V (ontinued) NMA Starter Size ont. Amps am
More informationProduct Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers
Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More informationL-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600
January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC
More informationElectrical Notes: For PDC-1 provide a minimum of 6 spare circuits.
Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous
More informationCOMMENTS: PLEASE SEE A/E COMMENTS
OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: BUILDING REFERENCE: SUBJECT: DISTRIBUTION SWITCHBOARDS - RESUBMITTED 1 TIME(S) DATE RECIEVED: v 07, 2014 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationCH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001
2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationSeries G Moulded Case. Circuit Breakers. Series G Moulded Case Circuit Breakers 1
1 Series G Moulded Case Circuit Breakers Description Series G Globally Accepted Breaker General Information........................................... 2 Product Line Overview.........................................
More informationPROJECT MANAGEMENT Transmittal No 17D
GH Phipps Construction Co. 5995 Greenwood Plaza Blvd. Suite 00 Greenwood Village CO 80-470 PROJECT MANAGEMENT Transmittal No 7D5780-00 PROJECT: Thistle-Valmont Square Interior & Exterior Renovation DATE:
More informationWestinghouse Molded Case Circuit Breakers Engine Generator FG Amperes
Circuit s FG 15-150 Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11 Cutler-Hammer
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
15 0 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased performance in considerably less space than
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More information2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards
Panelboards Solar Applications.7 Contents Description Introduction.............................. Product Selection Guide.................. EZ Box and EZ Trim........................ Type PRL1a...........................
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More informationInstallation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches
Instruction Leaflet IL 0106001E Contents Description Page Introduction.......................... Installation............................ Manual Operation and Thermal Magnetic Trip Unit Adjustment.......................
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating
More information1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch
. Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A
More informationSupplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents
-1 May 008 Circuit Breakers & Supplementary Protectors Contents Description Page Series C vs. Series G Typical Applications........................................... - Series G Globally Accepted Breaker
More informationInstallation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches
Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. DEATH,
More informationTable Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
-22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More information5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection
.11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationCANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range
CANADIAN BROCHURE 2017 Tmax Range 5 ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE Reliable solution ABB solution for enclosed circuit breaker ABB s enclosed circuit breakers offer all the advantages and
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMolded Case Circuit Breakers
SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A
More informationEnclosed Circuit Breakers
Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationEOEM panelboard and switchboard (OPS) Program
Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit
More informationNEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationQuik-Spec Electrical Gear
Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................
More informationMolded Case Circuit Breakers. Conductor Size. Maximum. Maximum. Notes
.6 Molded ase ircuit reakers Eaton s mining service circuit breakers provide short-circuit protection as specified in the code of Federal Regulations 30 FR 75.601-. E 5/400 K frame and 400/600 L frame
More informationInstallation Instructions for TMQV Circuit Breakers and Molded Case Switches
DEH41188 Installation Instrucitons Contents Description Introduction............................. Installation.............................. Manual Operation........................ Inspection and Field
More informationEffective December 2015 Supersedes September 2013
Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationMolded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3. BuyLog Catalog 3-29
Molded Case Circuit Breakers 15-100A Thermal Magnetic Trip Type TEY/TEYF Noninterchangeable Trip Bolt-on 480Y/277V Class Section 3 Page Updated 09 / 2011 TEY and TEYF breakers are one-inch wide per pole,
More informationDisconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle
Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies
More information1.1. Switching Devices
. Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................
More informationCutler-Hammer. January 2001
Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.
More information4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...
.5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,
More informationEnclosed Circuit Breakers
Enclosed Circuit Breakers Complete AssembliesMolded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit,
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationA. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.
16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional
More informationMolded Case Circuit Breakers
Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationType MP-T Type MP-HT Type MP-MT
CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List
More informationMolded Case Circuit Breakers Reference Guide
Molded Case Circuit Breakers Plug-In Breakers Panelboard Breakers QT QP, QPP QPH, QPPH HQP, HQPP HQPPH QPJ BL BLH HBL BQD, BQD NGB NEB HEB Page 1-25 1-27, 1-29 1-27, 1-29 1-24, 1-29 1-24, 1-29 1-29 -18-18
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationMolded Case Circuit Breakers Section 6 Q-Line Circuit Breakers
Q-Line Circuit Breakers Accessories 240V Class Terminals (Lugs) for Q-Line Circuit Breakers Ampere Rating Termination Type Wire Range (Cu/Al) Product Number 15-60 Lug (line only) 14-6/12-2 TQAL3A 15-60
More informationTHQL1120AF2 THQL1120AF2 Arc Fault BRKR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections
More informationMOLDED CASE CIRCUIT BREAKERS
EB -, -, -Poles; Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 EHB -, -, -Poles; 4 Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 -Pole, 77 Volts AC, 5 Volts DC➊ Underwriters Laboratories,
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationSeries G Moulded Case Circuit Breakers A for IEC & NEMA Applications
15 0 A for IEC & NEMA Applications Product Focus World-class accessories include: Q Circuit breaker W Thermal-magnetic trip unit, integrated on E Frame E Magnetic only trip unit, integrated on E Frame
More informationDry-Type Transformers Mini-Power Centers
Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant
More information3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...
.6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationHeavy Duty Safety Switches
eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................
More information