MEG Approval Meter Equipment Group
|
|
- Solomon Barrett
- 5 years ago
- Views:
Transcription
1 MEG Approval Meter Equipment Group
2 MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 97, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com. METERING As a market leader in electrical metering equipment, Milbank has set the standard for quality since 97. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility s requirements. ENCLOSURES Milbank s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments. ENCLOSED CONTROLS Milbank doesn t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.
3 Table of Contents TABLE OF CONTENTS Air Conditioner Disconnects 0-60 amp AC disconnects amp AC disconnect with 0 amp GFCI receptacle... 6 Hot tub disconnects... 7 Single Position Sockets 5 amp, 4 & 5 terminal, ringless amp, 4 & 5 terminal, ringless amp, 5 & 7 terminal, lever bypass, ringless amp, 4 & 5 terminal, lever bypass, ringless amp, 7 terminal, lever bypass, ringless... 0 amp, 4 terminal, lever bypass, ringless... 0 amp, 5 terminal, lever bypass, ringless amp, 7 terminal, lever bypass, ringless amp (480A continuous), 4 & 7 terminal, bolt-in bypass, ringless... 6 Meter Mains amp, 4 terminal, ringless amp, 4 terminal, with load center, ringless amp, 4 terminal, with and without load center, ringless... 0 Multi-Position 00 amp, 4 terminal, ringless amp, 4 terminal, ringless amp, 4 terminal, ringless amp, 5 terminal, ringless, Heavy Duty Lever Bypass amp, 7 terminal, ringless, Heavy Duty Lever Bypass... 5 Multi-Position Meter Mains 00 & 00 amp, 4 terminal, ringless... 6 Pedestals amp, 4 terminal, meter main with load center pedestal Miscellaneous Replacement parts & Accessories Reference information Index... 9
4 4 CATALOG NUMBER LOGIC Catalog Number Logic How our product catalog numbers are derived Milbank drawing number TG: Triplex ground QG: Quadplex ground Lugs (Ø or Ø, 50 or 600 kcmil Single: K, K, K5, K7 Twin: K, K4, K6, K8 Utility specific designation U448-X-QG-5T9-K-BLG-ARE U: UL Listed S: Non-UL Listed UAP: UL, aluminum, painted U: UL Listed S: Non-UL Listed UAP: UL, aluminum, Hub Openings & Closing Plates -O Blank top -RL Small hub opening -R Large hub opening -XL Small closing plate -X Large closing plate -RXL Large hub opening adapted to small closing plate -RRL Large hub opening adapted to small hub opening -PXL Closing plate packed inside 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 -WL hub -YL ¼ hub -ZL ½ hub -DL hub -EL ½ hub -F hub -G ½ hub -H 4 hub BLG: Barrel lock / guard provision painted KK: Horn bypass BL: Barrel lock U7040-RL-TG-KK-5T9-BL-AUT Milbank drawing number TG: Triplex ground QG: Quadplex ground 5th terminal designation 5T6: installed at 6:00 5T9: installed at 9:00 Utility specific designation and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
5 Air Conditioner Disconnects 0-60 Amp Fusible & Non-Fusible 5 AC DISCONNECTS U80 U8 U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and, also, complies with Article in the NEC. To ensure the safest conditions, we designed our disconnect pullouts to be removable so they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, nonfading finish Amp Ø 40 VAC Air Conditioner Disconnects Catalog Number Amp Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Dimensions Wire Rating Range CU/AL CU AL D" W" H" CU C AL C U80 60 Non-Fusible 0.5 #4-# #-# # /75 60 /75 U8 60 Non-Auto 0.5 #4-# #-# # /75 60 /75 U8 0 Fusible.5 #4-# #4-# # /75 60 /75 U86 60 Fusible 0. #4-# #4-# # /75 60 /75 UL listed as Enclosed Pullout Switch Type R rain resistant One-inch concentric knockouts and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
6 6 AC DISCONNECTS Air Conditioner Disconnects 60 Amp With 0 Amp GFCI Receptacle U8-0GWR Specifications Meets NEC #0.6 requirements UL listed as Power Outlet Type R enclosure In-use cover* Duplex ground connector " concentric knockouts Ø, 40 volt 60 amp, non-fused 0 amp GFCI receptacle Reset/test button Weather and tamper resistant Meets NEC #406.8 requirements 60 Amp Ø, 40 VAC Air Conditioner Disconnect with GFCI Receptacle Catalog Number Type Max H.P. Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions Wire Rating CU AL D" W" H" CU C AL C U8-0GWR Non-Fusible 0 6 #4-# #-# # /75 60 /75 Disconnect Pullouts: To ensure the safest conditions, Milbank disconnect pullouts are reversible so they may be reinstalled in the OFF position. Padlock Provision: All units are designed with a padlock provision on the cover for security. *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle). and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
7 Hot Tub Disconnects Type R Enclosures 7 HOT TUB DISCONNECTS U488-O-50GB U488-O-60GB Specifications 40 volt ground fault protection UL listed, Type R rain resistant -pole, 50 or 60 amp GFCI breaker protection Compact size Three or four wire installation Ø, 0/40 VAC Standard package of Two extra one-pole breaker spaces 00 amp overall rating Easy to install 00 Amp Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Catalog Number Breaker Amp Type Weight (lbs.) Line/Load Wire Range Ground Wire Range CU/AL Dimensions CU AL D" W" H" U488-O Breaker Provision 7 #4-/0 #4-/0 #4-/0 7 8 U488-O-50GB 50 Breaker 8 #4-/0 #4-/0 #4-/0 7 8 U488-O-60GB 60 Breaker 8 #4-/0 #4-/0 #4-/0 7 8 and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
8 8 5 AMP SINGLE POSITION SOCKETS Single Position Sockets 5 Amp 4 & 5 Terminal Ringless 600 VAC U845-XL-TG-HSP 5 Amp 4 Terminal Ringless Single Position ØW Catalog Number Material Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U845-XL-TG-HSP Steel OH C.P. #6-/0 #6-/0 None UAP845-XL-TG-HSP Aluminum OH C.P. #6-/0 #6-/0 None Amp 5 Terminal Ringless Single Position ØW Catalog Number Material Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U845-XL-TG-5T-HSP Steel OH C.P. #6-/0 #6-/0 None UAP845-XL-TG-5T-HSP Aluminum OH C.P. #6-/0 #6-/0 None Fifth Terminal: For field-installed fifth terminal, order catalog number 5T8K. Connectors: Extruded aluminum connectors are tin plated. Units are supplied with a triplex ground. Hubs: For proper hub selection, see hub suffix chart on accessories page. MEG APPROVED
9 Single Position Sockets 00 Amp 4 & 5 Terminal Ringless 600 VAC 9 00 AMP SINGLE POSITION SOCKETS U70-RL-TG-HSP U850-XL-TG-HSP-PL U980-O-HSP U7040-O-TG-HSP Amp 4 Terminal Ringless Single Position ØW Catalog Number Material Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 5 U70-RL-TG-HSP Steel OH H.O. #6-50 #6-50 None UAP70-RL-TG-HSP Aluminum OH H.O. #6-50 #6-50 None U850-XL-TG-HSP-PL Steel OH/UG C.P. #6-50 #6-50 None 4 5 U7040-XL-TG-HSP Steel OH/UG C.P. #6-50 #6-50 None UAP7040-XL-TG-HSP Aluminum OH/UG C.P. #6-50 #6-50 None U7040-O-TG-HSP Steel UG Blank #6-50 #6-50 None UAP7040-O-TG-HSP Aluminum UG Blank #6-50 #6-50 None ,,,,,, 7040, U980-O-HSP Steel UG Blank #6-50 #6-50 None Amp 5 Terminal Ringless Single Position ØW, Catalog Number Material Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 5 U7040-XL-TG-5T-HSP Steel OH/UG C.P. #6-50 #6-50 None UAP7040-XL-TG-5T-HSP Aluminum OH/UG C.P. #6-50 #6-50 None 4 8 5,, U980-O-5T-HSP Aluminum UG Blank #6-50 #6-50 None 4 5 Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Fifth Terminal: For field-installed fifth terminal, order catalog number K5T. Connectors: Extruded aluminum connectors are tin plated. Units are supplied with a triplex ground., MEG APPROVED
10 0 5 AMP LEVER BYPASS SOCKETS Single Position Lever Bypass 5 Amp 5 & 7 Terminal Ringless 600 VAC U505-XL-TG-HSP 5 Amp Ringless Lever Bypass Single Position ØW Catalog Number Material Terminal Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U505-XL-TG-HSP Steel 5 OH/UG C.P. #6-/0 #6-/0 Lever , UAP505-XL-TG-HSP Aluminum 5 OH/UG C.P. #6-/0 #6-/0 Lever , 5 Amp Ringless Lever Bypass Single Position Ø4W Catalog Number Material Terminal Service Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U506-XL-TG-HSP Steel 7 OH/UG C.P. #6-/0 #6-/0 Lever , UAP506-XL-TG-HSP Aluminum 7 OH/UG C.P. #6-/0 #6-/0 Lever , Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Connectors: Extruded aluminum connectors are tin plated. MEG APPROVED
11 Single Position Lever Bypass 00 Amp 4 & 5 Terminal Ringless 600 VAC 00 AMP LEVER BYPASS SOCKETS U980-X-HSP U9550-RRL-QG-HSP U955-X-QG-HSP Catalog Number Material Terminal Service Hub Amp Ringless Lever Bypass Single Position ØW 4 Connectors CU/AL Bypass Dimensions 96 Knockouts D" W" H" 4 U980-X-HSP Steel 4 OH/UG C.P. #6-50 Lever U9550-RRL-QG-HSP Steel 5 OH H.O. #6-50 Lever U955-X-QG-HSP Steel 5 OH/UG C.P. #6-50 Lever ,,, UAP955-X-QG-HSP Aluminum 5 OH/UG C.P. #6-50 Lever U96-X-HSP Steel 5 OH/UG C.P. 8"x6 Studs Lever , UAP96-X-HSP Aluminum 5 OH/UG C.P. 8"x6 Studs Lever , Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Fifth Terminal: For field installed fifth terminal on the U980, order K866. Connectors: Extruded aluminum connectors are tin plated. For the U96-X stud-type unit, order connector kits separately. Order two kits to cover both line and load side: K59 (50 kcmil) or K540 (600 kcmil.) See accessories page., MEG APPROVED
12 00 AMP LEVER BYPASS SOCKETS Single Position Lever Bypass 00 Amp 7 Terminal Ringless 600 VAC U9700-RRL-QG-HSP U970-X-QG-HSP U06-X-HSP 00 Amp 7 Terminal Ringless Lever Bypass Single Position Ø4W Catalog Number Material Terminal Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U9700-RRL-QG-HSP Steel 7 OH H.O. #6-50 Lever UAP9700-RRL-QG-HSP Aluminum 7 OH H.O. #6-50 Lever U970-X-QG-HSP Steel 7 OH/UG C.P. #6-50 Lever ,,, UAP970-X-QG-HSP Aluminum 7 OH/UG C.P. #6-50 Lever U06-X-HSP Steel 7 OH/UG C.P. 8" x 6 Studs Lever , UAP06-X-HSP Aluminum 7 OH/UG C.P. 8" x 6 Studs Lever ,, Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Isolated Neutral: For field-installed isolated neutral for U970, order K047. Connectors: Extruded aluminum connectors are tin plated. For the U06 stud-type unit, order connector kits separately. Order kits to cover both line and load side: K08 (50 kcmil) or K44 (600 kcmil.) See accessories page. MEG APPROVED
13 Single Position Lever Bypass 0 Amp 4 Terminal Ringless 600 VAC 0 AMP LEVER BYPASS SOCKETS U46-X-HSP U67-X-HSP U67-X-HSP U9-O-KL-KL-HSP U797-O-KL-KL-HSP U4-O-HSP Amp 4 Terminal Ringless Lever Bypass Single Position ØW Catalog Number Material Service Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" 4 U46-X-HSP Steel OH C.P. 8 x 6 Studs 8 x 6 Studs U67-X-HSP Steel OH C.P. 8 x 6 Studs 8 x 6 Studs U67-X-HSP Steel OH/UG Blank 8 x 6 Studs 8 x 6 Studs U9-O-KL-KL-HSP Steel UG Blank U797-O-KL-KL-HSP Steel UG Blank () #4-600 or () /0-50 () # () #4-600 or () /0-50 () # U4-O-HSP Steel UG Blank 8" x 6 Studs 8 x 6 Studs UAP4-O-HSP Aluminum UG Blank 8" x 6 Studs 8 x 6 Studs Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Order two connector kits to cover both line and load. See accessories page. MEG APPROVED
14 4 0 AMP LEVER BYPASS SOCKETS Lever Bypass Single Position 0 Amp 5 Terminal Ringless 600 VAC U949-X-HSP U5864-X-HSP 0 Amp 5 Terminal Ringless Lever Bypass Single Position ØW Catalog Number Material Terminal Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U949-X-HSP Steel 5 OH C.P. 8" x 6 Studs Lever 6 8 4, UAP949-X-HSP Aluminum 5 OH C.P. 8" x 6 Studs Lever 6 8 4, U5864-X-HSP Steel 5 OH/UG C.P. 8" x 6 Studs Lever , UAP5864-X-HSP Aluminum 5 OH/UG C.P. 8" x 6 Studs Lever , Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Order two connector kits to cover both line and load. See accessories page. U5864: The U5864 will not accept twin lugs (the K540 connector will accept conductors /0 50 max). MEG APPROVED
15 Lever Bypass Single Position 0 Amp 7 Terminal Ringless 600 VAC 5 0 AMP LEVER BYPASS SOCKETS U566-X-HSP U0-O-HSP 0 Amp 7 Terminal Ringless Lever Bypass Single Position Ø4W Catalog Number Material Terminal Service Hub Connectors CU/AL Bypass Dimensions Knockouts D" W" H" 4 U566-X-HSP Steel 7 OH/UG C.P. " x Studs Lever , UAP566-X-HSP Aluminum 7 OH/UG C.P. " x Studs Lever , U0-O-HSP Steel 7 UG Blank 8" x 6 Studs Lever Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Lever Bypass: The lever supplies clamping action and operates bypass device. Connectors: Extruded aluminum connectors are tin plated. Order two connector kits to cover both line and load. See accessories page. U566: The U566 will accept an isolated neutral kit K604. / stud lug kits K4 two position #6-50 kcmil of K400 for a single wire #4-600 or () /0-50 kcmil MEG APPROVED
16 6 600 AMP BOLT-IN BYPASS SOCKETS Bolt-In Bypass Single Position 600 Amp (480A Cont.) 7 Terminal Ringless FPL approved only 4667 U4667-X Amp (480A Cont.) Ringless Bolt-In Bypass Single Position FPL Only Catalog Number Approved Utilities Material Terminal Hub Ground Lug Dimensions Knockouts D" W" H" U4667-X-858 FP&L Steel 7 C.P. /0-/ , UA4667-X-859 FP&L Aluminum 7 C.P. /0-/ , U4667-XT-956 FP&L Steel 7 () C.P. /0-/ , UA4667-XT-957 FP&L Aluminum 7 () C.P. /0-/ , Hubs: The -X unit is supplied with a large closing plate in the top. The -XT units are supplied with large closing plates in the top. For proper hub selection, see the hub suffix chart on the accessories page. Isolated Neutral Kit: For an isolated neutral on the 7-terminal sockets, order catalog number Z708-MO. Connectors: The 4-terminal units require a total of 5 connectors. The 7-terminal units require a total of 8 connectors. The 7-terminal units are supplied with two ground lugs. Order line and load connectors as extra. See chart on next page for ordering information. Bolt-In Bypass: These units offer a provision for a utility-supplied bolt-in bypass. MEG APPROVED
17 Bolt-In Bypass Single Position Connector Kits AMP BOLT-IN BYPASS SOCKETS 4 Terminal, ØW Connector Kits Catalog Number Wire Range Type Wire Entry Z7097-AC #6-50 Twin Side Z70469-AC #-500 Twin Side Z7096-AC Z7098-AC Z7099-AC Z AC #6-50 Twin Rear Z70540-AC #6-50 Quad Rear 7 Terminal, Ø4W Connector Kits Z709-AC Z70845-AC Z70540-AC Z AC Bolt-on type lugs for Milbank stud type meter mounting devices are made of 606-T6 aluminum to provide high strength and high conductivity. All lugs are tinplated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug. Catalog Number Wire Range Type Wire Entry Z7096-AC /0-800 Single Side Z709-AC /0-800 Single Front Z7098-AC #4-50 Twin Front Z7099-AC #6-50 Twin Side Z70469-AC #-500 Twin Side Z AC #4-500 Twin Front Z70845-AC #6-50 Triple Front
18 AMP METER MAIN Meter Main Amp 4 Terminal Ringless 0/40 VAC 6 U584-RL-50-HSP 584 UAP504-XL-FMG Amp 4 Terminal Ringless Meter Main ØW Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts Line Load D" W" H" U584-RL-00-HSP Steel OH C.P. #6-50 CB U584-RL-50-HSP Steel OH C.P. #6-50 CB U584-RL-00-HSP Steel OH C.P. #6-50 CB Amp 4 Terminal Ringless Meter Main Load Center ØW Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts Line Load D" W" H" UAP504-XL-FMG* Aluminum OH/UG C.P. #6-50 CB ,, * Wireway: Provided with underground pull section wireway with removable cover. UAP504 Bussing: Load side bus bars and circuit breaker interior are made from plated copper. Breakers: UAP504 Breaker section has provision for six double pole plug-in type circuit breakers. All circuit breakers will be parallel. To comply with NEC wire bending space requirements the maximum breaker amperage is 00 amp restricted to /0 copper conductor. Breaker Chart for UAP504 Manufacturer Compatible Models AIC Rating Siemens QN, QNR, QP 0K Cutler-Hammer BR, HQP, QPGF 0K G.E. TQL, THQL-GF 0K Square D Homeline 0K
19 Meter Main with Load Center Amp 4 Terminal Ringless 0/40 VAC AMP METER MAIN WITH LOAD CENTER U666-XTL-00-HSP Amp 4 Terminal Ringless Meter Main ØW Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts D" W" H" U666-XTL-00-HSP Steel OH/UG () C.P. # U666-XTL-50-HSP Steel OH/UG () C.P. # U666-XTL-00-HSP Steel OH/UG () C.P. # Hubs: Supplied with two closing plates packed inside. Order hubs as a separate item. For proper hub selection, refer to the hub suffix chart on the accessories page. Fifth Terminal: For field installed fifth terminal, order K5T. Breakers: KAIC main breakers factory installed Main Breaker: also available with amp breakers, consult factory. Sub Feed Lugs: #6-50 sub feed lugs provided on 0 circuit interior. Not available on 0 circuit interior. See accessories page for generator interlock kits. MEG APPROVED
20 0 0 AMP MULTI-POSITION SOCKETS Meter Main & Meter Main w/ Load Center 0 Amp 4 Terminal Ringless 0/40 VAC U667-X-/00-HSP U5890-X- /00-HSP U589-X- /00-HSP Amp 4 Terminal Ringless Meter Main ØW Lever Bypass Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts Line Load D" W" H" *U667-X-HSP Steel OH/UG C.P. 8 x 6 Studs U667-X-/50-HSP Steel OH/UG C.P. 8 x 6 Studs CB U667-X-/00-HSP Steel OH/UG C.P. 8 x 6 Studs CB Amp 4 Terminal Ringless Meter Main ØW Lever Bypass Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts Line Load D" W" H" U5890-X-/50-HSP Steel OH/UG C.P. 8 x 6 Studs CB U5890-X-/00-HSP Steel OH/UG C.P. 8 x 6 Studs CB Amp 4 Terminal Ringless Meter Main w/ Load Center ØW Lever Bypass Catalog Number Material Service Hub Connectors CU/AL - Line Dimensions Knockouts Line Load D" W" H" 4 U589-X-/00-MLK-HSP Steel OH/UG C.P. 8 x 6 Studs CB HSP : Has a stainless steel hasp Short Circuit Current Withstand Rating: K AIC standard. Breakers: Units come with main breakers. *U667-X-HSP breaker sold separately. Fifth Terminal: For field mounted fifth terminal order catalog number K865. MEG APPROVED
21 Multi-Position Sockets 00 Amp 4 Terminal Ringless 00 VAC 00 AMP MULTI-POSITION SOCKETS U49-XL-HSP Amp per Position 4 Terminal Ringless Multi-Position ØW Catalog Number Positions Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" U49-XL-HSP C.P. #6-50 #6-/0 None , U49-XL-HSP C.P. #6-50 #6-/0 None 4 8 6, U494-XL-HSP 4 C.P. #6-50 #6-/0 None , U495-XL-HSP 5 C.P. #6-50 #6-/0 None , U496-XL-HSP 6 C.P. #6-50 #6-/0 None , Hubs: Units are supplied with closing plate at each end. For proper hub selection, see the hub suffix chart on the accessories page. Fifth Terminal Kit: For field-mounted fifth terminal, order catalog number 5T8K in the 6 o clock position. Connectors: Extruded aluminum connectors are tin plated. Bonding ground is furnished. Bussing: Units include 5 6" x aluminum bussing. MEG APPROVED
22 50 AMP MULTI-POSITION SOCKETS Multi-Position Sockets 50 Amp 4 Terminal Ringless 00 VAC U-X-HSP Amp per Position 4 Terminal Ringless Multi-Position ØW Catalog Number Positions Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 5 U-X-HSP C.P. Studs #6-50 None U-X-HSP C.P. Studs #6-50 None U4-X-HSP 4 C.P. Studs #6-50 None U5-X-HSP 5 C.P. Studs #6-50 None U6-X-HSP 6 C.P. Studs #6-50 None Hubs: Units are supplied with closing plates. For proper hub selection, see the hub suffix chart on the accessories page. Fifth Terminal Kit: For field-mounted fifth terminal, order catalog number K5T. Connectors: Line wire section is supplied with 8-6 studs with hex head nuts and captive Belleville washers. Order connector kits separately. One kit per unit. See accessories page. MEG APPROVED
23 Multi-Position Sockets 00 Amp 4 Terminal Ringless 00 VAC 00 AMP MULTI-POSITION SOCKETS U5-X-HSP Amp per Position 4 Terminal Ringless Multi-Position ØW Steel Catalog Number Aluminum Catalog Number Positions Hub Connectors CU/AL Dimensions Knockouts Line Load D" W" H" 4 5 U5-X-HSP UAP5-X-HSP C.P. Studs # U5-X-HSP UAP5-X-HSP C.P. Studs # U54-X-HSP UAP54-X-HSP 4 C.P. Studs # U55-X-HSP UAP55-X-HSP 5 C.P. Studs # U56-X-HSP UAP56-X-HSP 6 C.P. Studs # Hubs: Units are supplied with closing plates. For proper hub selection, see the hub suffix chart on the accessories page. Fifth Terminal Kit: For field-mounted fifth terminal, order catalog number K5T. Connectors: Line wire section is supplied with /8-6 studs with hex head nuts and captive Belleville washers. Order connector kits separately. One kit per unit. See accessories page MEG APPROVED
24 4 00 AMP MULTI-POSITION SOCKETS HD Lever Multi-Position Sockets 00 Amp 5 Terminal Ringless 600 VAC U87-XT-HSP Amp per Position 5 Terminal Ringless Multi-Position ØW Catalog Number Positions Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U87-XT-HSP () C.P. 8"-6 Studs #6-50 Lever U87-XT-HSP () C.P. 8"-6 Studs #6-50 Lever U874-XT-HSP 4 () C.P. 8"-6 Studs #6-50 Lever U875-XT-HSP 5 () C.P. 8"-6 Studs #6-50 Lever U876-XT-HSP 6 () C.P. 8"-6 Studs #6-50 Lever ,,,,, Hubs: Units are supplied with two closing plates. For proper hub selection, see the hub suffix chart on the accessories page. Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Connectors: For line side connector kits, order separately. Order one kit per unit. See accessories page. MEG APPROVED
25 HD Lever Multi-Position Sockets 00 Amp 7 Terminal Ringless 600 VAC 5 00 AMP MULTI-POSITION SOCKETS U7-XT-HSP Amp per Position 7 Terminal Ringless Multi-Position Ø4W Catalog Number Positions Hub Connectors CU/AL Dimensions Knockouts Bypass Line Load D" W" H" 4 U7-XT-HSP () C.P. 8"-6 Studs #6-50 Lever U7-XT-HSP () C.P. 8"-6 Studs #6-50 Lever U74-XT-HSP 4 () C.P. 8"-6 Studs #6-50 Lever U75-XT-HSP 5 () C.P. 8"-6 Studs #6-50 Lever U76-XT-HSP 6 () C.P. 8"-6 Studs #6-50 Lever ,,,,, Hubs: Units are supplied with two closing plates. For proper hub selection, see the hub suffix chart on the accessories page. Bypass: Lever supplies clamping action on meter spades and also operates bypass device. Connectors: For line side connector kits, order separately. Order one kit per unit. See accessories page. MEG APPROVED
26 AMP HORN BYPASS MULTI-POSITION Multi-Position Meter Mains 5 & 00 Amp 4 Terminal Ringless 0/40 VAC U854-X-HSP U866-X-HSP 5 Amp Per Position 4 Terminal Multi-Position Sockets Ringless Catalog Number amp Positions Service Hub Main Bus Rating amp Connector Size Dimensions Line Load D" W" H" U85-X-HSP 5 OH/UG CP 00 8" x 6 Stud CB U85-X-HSP 5 OH/UG CP 00 8" x 6 Stud CB U854-X-HSP 5 4 OH/UG CP 400 8" x 6 Stud CB U855-X-HSP 5 5 OH/UG CP 400 8" x 6 Stud CB U856-X-HSP 5 6 OH/UG CP 400 8" x 6 Stud CB Amp per Position 4 Terminal Multi-Position Sockets Ringless Catalog Number amp Positions Service Hub Main Bus Rating amp Connector Size Dimensions Line Load D" W" H" U86-X-HSP 00 OH/UG CP 50 8" x 6 Stud CB U86-X-HSP 00 OH/UG CP 00 8" x 6 Stud CB U864-X-HSP 00 4 OH/UG CP 400 8" x 6 Stud CB U865-X-HSP 00 5 OH/UG CP 600 8" x 6 Stud CB U866-X-HSP 00 6 OH/UG CP 600 8" x 6 Stud CB Connector Kits* Size Suffix Kit Number Compatible With Wire Range Single Twin -K K59 U85-56, U86-66 #6-50 -K K540 U854-56, U # K K50 U854-56, U86-66 #6-50 -K4 K54 U #-600 Breaker Chart Manufactuer amp 5 or less Cutler Hammer BR, WBJ QP, BR Siemens QNR QP G.E. THQ THQ Square D. _ Homeline Fifth Terminal: For field mounted fifth terminal, order catalog number K8. Order one per meter position. Breakers: Units have provision for one double pole main per meter position. Breakers not included. See breaker chart. Knockouts: See next page for drawings and knockout configurations. MEG APPROVED
27 Meter Main with Load Center Pedestal Amp 4 Terminal Ringless 0/40 VAC 7 METER MAIN W/ LOAD CENTER PEDESTAL Grade Level 4 Specifications U56-O-00S-FMG UL listed File E90945 K545 stabilizer foot included with pedestal for field installation 00 amp maximum, 0/40 V, ØW Ringless type meter socket with stainless steel latch Pedestals with factory installed breakers are KAIC Type R construction for durable outdoor use ASA 6 grey polyester powder coat finish Wire terminations accept copper or aluminum conductors Line & Neutral: () #6-50 kcmil per phase, Line Ground: (4) #4-/0 Load (CB): /0 to 00 kcmil per pole for 00 amp breaker. Load neutral: () #6-50 kcmil Load ground: () #4-/0, (4) #4 6 Commercial grade, plug-in main circuit breaker. Available in 00, 5, 50 & 00 AMP. Type UQFPH-M. 4 circuit plated copper interior accepts () -pole or (4) -pole standard plug-in type circuit breakers. Four branch circuits rated 5 amp max. Acceptable manufacturers: Cutler-Hammer, GE, Siemens or Square D Homeline MEG APPROVED
28 AMP METER MAIN W/ LOAD CENTER PEDESTAL Meter Main with Load Center Pedestal Amp 4 Terminal Ringless 0/40 VAC Amp Meter Main with Load Center Pedestal Ringless Catalog Number Powerheads Amp Main Breaker Interior Dimensions Knockouts D" W" H" U56-O-00S-FMG Single 00 UQFP-M-00 (Series) 4 circuit , U56-O-5S-FMG Single 5 UQFP-M-5 (Series) 4 circuit , U56-O-50S-FMG Single 50 UQFP-M-50 (Series) 4 circuit , U56-O-00S-FMG Single 00 UQFP-M-00 (Series) 4 circuit , U56-O-00P-FMG Single 00 UQFP-M-00 (Parallel) 4 circuit , U56-O-5P-FMG Single 5 UQFP-M-00 (Parallel) 4 circuit , U56-O-50P-FMG Single 50 UQFP-M-00 (Parallel) 4 circuit , U56-O-00P-FMG Single 00 UQFP-M-00 (Parallel) 4 circuit , U56-O-FMG Single Breaker provision 4 circuit , U57-O-00S-FMG Double 00 () UQFP-M-00 (Series) 4 circuit , U57-O-5S-FMG Double 5 () UQFP-M-5 (Series) 4 circuit , U57-O-50S-FMG Double 50 () UQFP-M-50 (Series) 4 circuit , U57-O-00S-FMG Double 00 () UQFP-M-00 (Series) 4 circuit , U57-O-00P-FMG Double 00 () UQFP-M-00 (Parallel) 4 circuit , U57-O-5P-FMG Double 5 () UQFP-M-00 (Parallel) 4 circuit , U57-O-50P-FMG Double 50 () UQFP-M-00 (Parallel) 4 circuit , U57-O-00P-FMG Double 00 () UQFP-M-00 (Parallel) 4 circuit , U57-O-FMG Double Breaker provision 4 circuit , Parallel to Series Conversion: For field converting from parallel wired to series wired order K594. Fifth Terminal: For field installed fifth terminal, order K5T. Penta Bolt Locking: For field installed pedestal fronts penta bolt locking, order K509. Receptacles: Consult factory for installed receptacle assemblies. Pad Mount Units: Pad mount pedestals are available. Order U58 (single meter) or U59 (double meter) prefix. K505 pad mount kit required. Order separately. MEG APPROVED
29 Meter Main with Load Center Pedestal 00 & 00 Amp 4 Terminal Ringless 0/40 VAC 9 00 & 00 AMP METER MAIN W/ LOAD CENTER PEDESTAL Grade Level U696-O-00-0GR-HSP 00 & 00 Amp Meter Main with Load Center Pedestal Ringless Connectors CU/AL Dimensions Knockouts Catalog Number Amp Service Interior Line Load D" W" H" U696-O-00-0GR-HSP 00 UG () #6-50 kcmil () #6-50 kcmil 8 circuit U696-O-00-0GR-HSP 00 UG () #6-50 kcmil () #6-50 kcmil 8 circuit Specifications & Features UL listed 00 amp maximum, 0/40 volt, single phase, three wire meter socket Short circuit withstand rating of K AIC Type R construction for durable outdoor use, one piece post lockable and sealable Direct bury pedestal Circuit breaker: available with 00 or 00 amp main breaker 8-circuit load center with feed through lugs Acceptable branch breaker manufacturers: Cutler-Hammer, GE, Siemens, or Square D Homeline Milbank grey polyester powder coat finish Wire terminations accept copper or aluminum conductors Line & neutral: () #6-50 kcmil per phase Line ground: (4) #4-/0 Load neutral: () #6-50 kcmil Load ground: () #4-/0, (4) #4/6 0 amp GFCI receptacle and 0 amp breaker factory installed. receptacles factory installed option available Stainless steel hasps Receptacles: Consult factory for installation of () 0 amp GFCI receptacle assemblies. Field installed 5th terminal kits MEG APPROVED
30 0 REPLACEMENT PARTS & ACCESSORIES Replacement Parts & Accessories For U56 U59 Pedestals K595-4 K595-0GR K595-GR K595-6GR K K595-/450 Z508 Lug landing base Z8994-SC With receptacle openings Z96 Without receptacle openings Z070 Hinged cover and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
31 Replacement Parts & Accessories For U56 U59 Pedestals REPLACEMENT PARTS & ACCESSORIES Q0 0 amp, pole circuit breaker Q0 0 amp, pole circuit breaker Q50 50 amp, pole circuit breaker Z MO 0 amp GFI receptacle NEMA 5-0GR Z70776-MO 0 amp receptacle NEMA TT-0 Z MO 50 amp receptacle NEMA 4-50R and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
32 ACCESSORIES Accessories Hubs and Closing Plates -RL Small hub opening -WL A754 -YL A755 -ZL A756 -DL A757 -EL A758 -XL A755 " hub " hub " hub " hub " hub Small closing plate -R Large hub opening -F A80 -G A8 -H A8 -X A9064 -RRL S84 " hub " hub 4" hub Large closing plate Large hub opening adapted to small hub oepning Suffix: Add to catalog number for factory installation of hub. Packaging: Individually packed units for field installation. Abbreviations: H.O. (hub opening), C.P. (closing plate). and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
33 Accessories Connector Kits, Closing Kits & Generator Interlock ACCESSORIES Connector Kits For Use with 8"-6 Stud Type Units Only Bypass Link Single Twin Suffix Part # ( per set) - Ø Suffix Part # ( per set) - Ø K K K K K K or () /0-50* KL K50L 6-50 (non rotating) KL K540L or () /0-50* (non rotating) K4 K Suffix Part # (4 per set) - Ø Suffix Part # (4 per set) - Ø K5 K K6 K K7 K or () /0-50* K8 K K880 (sold in pairs) Note Consult factory for proper connector kits for studded meter sockets. *For () /0-50, conductors must be of same size. Closing Covers Generator Interlock Meter Closing Plate (Ring Type / Ringless) Metal Closing Plate (For Ringless Sockets) Grey Plastic CP Clear Plastic K585 - large QN with small frame Q K580 - large frame QN with large frame QN K580 - small frame Q to small frame Q Disconnect Sleeve Anti-Inversion Clip Isolated Neutral Kit M5-44 Do not use with lever bypass sockets K480 K047 Consult factory for proper isolated neutral for meter sockets and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
34 4 ACCESSORIES Accessories Fifth Terminal, Tap Connectors & Block Assemblies Fifth Terminal 5T8K Amp Plug-In K5T - 00 Amp (Block with Square Hole) K865 - Heavy Duty Jaw Clamping (K866 without Neutral Wire) Tap Connectors ( per set) K4977-INT - Internal Hex K4977-EXT - External Hex K50-INT - Internal Hex (set of 4 w/ barrier) Replaces the load or line side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #6-50 kcmil load-side connector. K50 includes safety barrier extensions for applications over 00 VAC. Three lugs per kit. Triplex Ground K90 (For factory installed triplex ground, add suffix -TG to catalog number) 00 Amp Blocks (single sockets only) 00 Amp Blocks (single sockets only) BL Block Assembly BL Horn Bypass Block Assembly Z AO - Slotted Nut Assembly Z9074-AO - Horn Bypass Nut Assembly Z80965-AC - Neutral without Nut Z9095-AC - Hex Nut Set Screw K457 - Internal Hex Block Assembly (w/ meter support) K458 - External Hex Block Assembly (w/ meter support) K459 - Internal Hex Horn Bypass Block Assembly (w/ meter support) K450 - External Hex Horn Bypass Block Assembly (w/ meter support) Z9665-AO - Internal Nut Assembly Z9664-AO - External Nut Assembly Z84898-AC - Neutral without Nut and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
35 Watthour Meter Forms Standard Forms Transformer Rated or Self-Contained 5 WATTHOUR METER FORMS SC SC TR TR TR and -WIRE FORMS S & S and -WIRE FORMS S & S with BYPASS -WIRE FORM S 5th Term. 9 o clock -WIRE FORM S with BYPASS -WIRE FORM S 5th Term. 6 o clock TR SC SC SC SC -WIRE FORM S with BYPASS ELEMENT -WIRE NETWORK FORM S 5th TERM. 9 o clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 9 o clock ELEMENT -WIRE NETWORK FORM S 5th TERM. 6 o clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 6 o clock TR TR SC SC TR -WIRE FORM 4S -WIRE FORM 4S WITH BYPASS or ELEMENT Ø4W Y or Y FORM 4S FORM 5S Y FORM 6S or ELEMENT Ø4W Y or FORMS 4S & 5S with BYPASS ELEMENT Ø4W Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT ØW, Ø4W, ØW FORM 5S ELEMENT ØW, Ø4W, ØW FORM 5S with BYPASS ELEMENT ØW, Ø4W, ØW FORM S or ELEMENT ØW, Ø4W, ØW FORM S with BYPASS or ELEMENT Ø4W Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT Ø4W Y or FORMS 8S & 9S FORMS 8S & 9S with BYPASS ELEMENT Ø4W Y FORM 6S ELEMENT Ø4W Y FORM 6S with BYPASS and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
36 6 METER FORMS Meter Forms Reference Information DIAGRAM A W with P.T. & C.T. Single Stator Meter(W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM B W with C.T. Single Stator Meter (W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM C W with C.T. s Single Stator Meter (W ) - Form 4S 6T Socket, Test Switch #TS DIAGRAM D W or W Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P C C C C P P C PN C C C P.T. I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD DIAGRAM E W with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM F W with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM G 4W Y with C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM H 4W Y with P.T. s & C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H P P PN C C C C C C P P PN C C C C C C P P P C C C C P C P P C C C LINE PT PT C.T. C.T. LOAD LINE C.T. C.T. LOAD LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. DIAGRAM I 4W Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 P P P PN C DIAGRAM I C C C C C DIAGRAM J 4W Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 P DIAGRAM J P PN C P C C C C C Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
37 Energization of Electrical Equipment Important Information for Installers 7 ENERGIZATION OF ELECTRICAL EQUIPMENT Important Note In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. Before Energizing A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. When Energizing A. Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. After Energizing A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. Recommended Torque for General Applications* Nominal Size Screw Joint Description Nut Head Type Torque (Inch Lbs.) 0 Brass Brass Nut or Extruded Hole All 0-5 inch lbs. 0 Steel Copper or Aluminum Busbar /8" All 5-0 inch lbs. 0 Steel Steel Nut or Extruded Hole; CU or AL Busbar > /8" All 0-5 inch lbs. Steel Aluminum Extruded Hole All 0-5 inch lbs. Steel Steel Nut or Extruded Hole All inch lbs. /4 Steel Aluminum Extruded Hole All inch lbs. /4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All inch lbs. 5/6 Steel Aluminum Extruded Hole Hex inch lbs. 5/6 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex inch lbs. /8 Steel Steel Nut Hex inch lbs. / Steel Steel Nut Hex inch lbs. * Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. CU: Copper AL: Aluminum and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
38 8 MATERIALS & FINISHES Materials & Finishes Reference Information Materials Steel Quality The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. Steel Sheet 6 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. (AISI G90) 4 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. Aluminum Extrusion Wire-Terminal: Alloy; 606-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 60-O & 606-O Aluminum Sheet 000 series aluminum sheet, H4, or 505 series aluminum sheet, H. Where applicable thicknesses range from Copper Sheet & Bus Electrolytic copper with tin plating in most applications. Insulating Materials In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. Finish Process Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. Metal Fastners Zinc-coated with a chromate dip. Ratings & Compliance Ratings & Compliance All Milbank electrical enclosures in this catalog are rated Type R Enclosure unless specified otherwise on the product s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 44, File E00), Test Switches (UL 44, File E65), Power Outlets (UL, File E90945), Panelboards (UL 67, File E68) and Pullout Switches (UL 49, File E06). Additional standards are utilized as applicable: Meter Sockets (ANSI C.7), Test Switches (ANSI C.9) and Panelboards (NEMA PB-). and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
39 Index 9 INDEX U5890-X-/50-HSP...0 U5890-X-/00-HSP...0 5T8K...4 A A A A A A A80... A8... A8... A BL BL CP-... K K K50... K50L... K59... K K540L... K54... K08... K08... K44... K44... K K K K K K K K K4977-EXT...4 K4977-INT...4 K50-INT...4 K K K K595-0GR...0 K595-GR...0 K595-/ K595-6GR...0 K K K5T...4 K M Q0... Q0... Q50... S84... U9-O-KL-KL-HSP... U-X-HSP... U-X-HSP... U4-X-HSP... U5-X-HSP... U6-X-HSP... U5-X-HSP... U5-X-HSP... U54-X-HSP... U55-X-HSP... U56-X-HSP... U797-O-KL-KL-HSP... U980-O-5T-HSP...9 U980-O-HSP...9 U0-O-HSP...5 U4-O-HSP... U7-XT-HSP...5 U7-XT-HSP...5 U74-XT-HSP...5 U75-XT-HSP...5 U76-XT-HSP...5 U85-X-HSP...6 U85-X-HSP...6 U854-X-HSP...6 U855-X-HSP...6 U856-X-HSP...6 U86-X-HSP...6 U86-X-HSP...6 U864-X-HSP...6 U865-X-HSP...6 U866-X-HSP...6 U87-XT-HSP...4 U87-XT-HSP...4 U874-XT-HSP...4 U875-XT-HSP...4 U876-XT-HSP...4 U96-X-HSP... U06-X-HSP... U49-XL-HSP... U49-XL-HSP... U494-XL-HSP... U495-XL-HSP... U496-XL-HSP... U505-XL-TG-HSP...0 U506-XL-TG-HSP...0 U566-X-HSP...5 U U8...5 U8-0GWR...6 U8...5 U850-XL-TG-HSP-PL...9 U U949-X-HSP...4 U46-X-HSP... U4667-X U4667-XT U488-O...7 U488-O-50GB...7 U488-O-60GB...7 U56-O-00P-FMG...8 U56-O-00S-FMG...8 U56-O-5P-FMG...8 U56-O-5S-FMG...8 U56-O-50P-FMG...8 U56-O-50S-FMG...8 U56-O-00P-FMG...8 U56-O-00S-FMG...8 U56-O-FMG...8 U57-O-00P-FMG...8 U57-O-00S-FMG...8 U57-O-5P-FMG...8 U57-O-5S-FMG...8 U57-O-50P-FMG...8 U57-O-50S-FMG...8 U57-O-00P-FMG...8 U57-O-00S-FMG...8 U57-O-FMG...8 U584-RL-00-HSP...8 U584-RL-50-HSP...8 U584-RL-00-HSP...8 U5864-X-HSP...4 U589-X-/00-MLK-HSP..0 U666-XTL-00-HSP...9 U666-XTL-50-HSP...9 U666-XTL-00-HSP...9 U667-X-/50-HSP...0 U667-X-/00-HSP...0 U667-X-HSP...0 U67-X-HSP... U67-X-HSP... U696-O-00-0GR-HSP...9 U696-O-00-0GR-HSP...9 U70-RL-TG-HSP...9 U7040-O-TG-HSP...9 U7040-XL-TG-5T-HSP...9 U7040-XL-TG-HSP...9 U845-XL-TG-5T-HSP...8 U845-XL-TG-HSP...8 U9550-RRL-QG-HSP... U955-X-QG-HSP... U9700-RRL-QG-HSP... U970-X-QG-HSP... U980-X-HSP... UA4667-X UA4667-XT UAP5-X-HSP... UAP5-X-HSP... UAP54-X-HSP... UAP55-X-HSP... UAP56-X-HSP... UAP4-O-HSP... UAP96-X-HSP... UAP06-X-HSP... UAP505-XL-TG-HSP...0 UAP506-XL-TG-HSP...0 UAP566-X-HSP...5 UAP949-X-HSP...4 UAP504-XL-FMG...8 UAP5864-X-HSP...4 UAP70-RL-TG-HSP...9 UAP7040-O-TG-HSP...9 UAP7040-XL-TG-5T-HSP...9 UAP7040-XL-TG-HSP...9 UAP845-XL-TG-5T-HSP...8 UAP845-XL-TG-HSP...8 UAP955-X-QG-HSP... UAP9700-RRL-QG-HSP... UAP970-X-QG-HSP... Z Z Z Z70776-MO... Z7096-AC...7 Z7097-AC...7 Z7098-AC...7 Z7099-AC...7 Z709-AC...7 Z70469-AC...7 Z70469-AC...7 Z AC...7 Z70540-AC...7 Z AC...7 Z MO... Z70845-AC...7 Z MO... Z80965-AC...4 Z84898-AC...4 Z8994-SC...0 Z9095-AC...4 Z9074-AO...4 Z AO...4 Z9664-AO...4 Z9665-AO...4 and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without
Duke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationLouisiana & Mississippi Area Catalog
Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationPennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog
Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy
More informationMeter Mounting Equipment DTE Energy Area
Meter Mounting Equipment DTE Energy Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationMeter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationTennessee Area Meter Mounting Equipment
Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationPSE&G Long Island Meter Mounting Equipment
PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationConsolidated Edison Orange & Rockland Meter Mounting Equipment
Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationMeter Mounting Equipment
Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles
More informationMeter Mounting Equipment Commonwealth Edison
Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice
More informationMeter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market
Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman
More informationUpstate New York Meter Mounting Equipment
Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationSelection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting
Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationSelection and Application Guide For use in New England EQUIPMENT
Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationRMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities
RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More information(CT, NH, ME, RI, VT, MA)
Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions
More informationSelection and Application Guide. Meter Mounting Equipment. For use in Iowa and Nebraska.
Selection and Application Guide Meter Mounting Equipment For use in Iowa and Nebraska www.talonmetering.com Meter Mounting Equipment Table of Contents Air Conditioning Disconnects Fused and Non-fused Rating
More informationCurrent Transformer, Termination & Disconnect Cabinets WE Energies Approved
Current Transformer, Termination & Disconnect Cabinets WE Energies Approved 2 TABLE OF CONTENTS Table of Contents Current Transformer Cabinets Overhead Entry... 4 Underground Entry and Underground Exit...
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationSelection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting
Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,
More informationMeter Centers Meter Mounting Devices
Meter Mounting Devices General General Information Materials: 16 gauge, galvanized steel, G-90 Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More information5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets
.1 Metering Products Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac All Eaton sockets are rated All single meter sockets are 600 Vac maximum and either UL labeled and are
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationSelection and application guide. For use in Texas. Meter Mounting Equipment.
Selection and application guide For use in Texas Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and General
More informationCABINET OPTIONS AND DESIGNATORS CODE LETTERS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSupplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT
Supplement to GUIDEBOOK OF REQUIREMENTS for Electric Service APPENDIX A: APPROVED METERING EQUIPMENT 2011 81 APPENDIX A: APPROVED METERING EQUIPMENT TABLE OF CONTENTS Approved Metering Equipment... A-1
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationSelection and application guide. For use in Ohio. Meter Mounting Equipment.
Selection and application guide For use in Ohio Meter Mounting Equipment www.landisandgyr.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction and general
More informationSelection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.
Selection and application guide For use in Kansas, Iowa, Missouri and Illinois Meter mounting equipment www.landisandgyr.com Contents Service Rating Positions Terminals Page Introduction and General Information
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal
DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More informationSPEEDFAX TM 2011 Meter Centers Contents
SPEEDFAX TM 011 Meter Centers Contents Single and Multiple s - -19 General Information - -3 Single Position s - Residential Types -4-5 Multiple Position s Residential Types -6-7 Single Position s Commercial
More informationWPS SERVICE MANUAL. Section Amp and Smaller - Common
Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase
More informationEaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals
Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents
More informationQuik-Spec Electrical Gear
Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationStandard switch modules (type WS) are designed for flexibility, space savings, & durability.
Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800
More informationCommercial & Industrial Product Catalog
Commercial & Industrial Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationCommercial Pedestals Product Catalog
Commercial Pedestals Product Catalog 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationSelection and application guide
Selection and application guide For use in Louisiana and Mississippi Meter Mounting Equipment www.talonmetering.com Meter Mounting Equipment Table of Contents Service Rating Positions Terminals Page Introduction
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More informationEnclosed Controls Product Catalog
Enclosed Controls Product Catalog Milbank Overview Energy At Work since 1927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationSingle Socket and Horizontal Metering
G nergy onnections Single Socket and orizontal Metering T Approved Single Socket Metering T Approved Application Information G s Single Socket Metering products are designed for residential use. They are
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationSingle Socket and Horizontal Metering
Midwest lectric Products Single Socket and orizontal Metering DT Approved Single Socket Metering DT Approved Application Information Midwest s Single Socket Metering products are designed for residential
More information