Meter Mounting Equipment DTE Energy Area
|
|
- Denis Houston
- 6 years ago
- Views:
Transcription
1 Meter Mounting Equipment DTE Energy Area
2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman Milbank Quality Metering Products for over 7 Years Milbank Manufacturing Company was established in 97 by Charles A. Milbank. Originally, the company manufactured high voltage switches; however, by 9 Milbank devoted itself primarily to the manufacture of sheet metal enclosures and related equipment for the electrical generation and distribution industry. Today we are an industry leader in the manufacture of electrical meter sockets. Through a national network of manufacturer s representatives we provide wholesale electrical distributors with quality electrical products for the utility, contractor, industrial and OEM markets. As the meter standards have changed, Milbank has been successful in adapting its product line to these changes. Our full scale engineering department designs products to meet customer specifications and satisfy all utility requirements. Milbank s employee base of over,000 with our five manufacturing facilities comprising almost 0,000 square feet gives us the flexibility to schedule, produce, and ship orders quickly. Currently, Milbank manufactures over 0,000 different catalog items, and this list continues to grow. Our unique product offering includes: Residential & Commercial Meter Sockets; Residential & Commercial Meter Pedestals; RV/MH Power Outlets, Pedestals, and Transformers; Commercial & Industrial Electrical Enclosures; Circuit Breakers; Disconnects & Safety Switches; Safety Sockets; Utility & Residential Secondary Pedestals; Hubs and related accessories. If you don t find a unit in this catalog to service your needs, send us your specifications and we will be happy to work with you. Our success has come from a loyal customer base that can rely on us to build quality products at a fair price in a timely manner. Our willingness and ability to design and produce new products to meet our customer demands is an important factor to remain competitive in today s electrical market. Milbank has been serving the electric utility & wholesale distribution industries for over 7 years with innovative, quality engineered products. So remember us for all of your meter mounting and related requirements, and we will be happy to serve you as we have in the past with dependable service and quality products! We take great pride in being one of the few family-owned businesses left in our industry. We are a third generation run business and truly believe that... FAMILY MAKES A DIFFERENCE!
3 TABLE OF CONTENTS Catalog Number Logic DISCONNECTS U Amp Non-Fusible AC Disconnect U Amp Fusible AC Disconnect U Amp Fusible AC Disconnect U8-0GR Amp Non-Fused AC Disconnect / 0 Amp GFCI Receptacle U88-O-0GB Amp Spa Box with GFCI Protection U88-O-0GB Amp Spa Box with GFCI Protection U88-O Spa Box with Breaker Provision & GFCI Protection TABLE OF CONTENTS SINGLE POSITION DTE NO. U787-O-TG Amp, Terminal, OH/UG ZSW U700-RL-TG Amp, Terminal, OH/UG ZSU U70-RL-TG Amp, Terminal, OH ZS SINGLE POSITION HEAVY DUTY LEVER BYPASS U980-RXL Amp, Terminal, W, OH/UG N/A U970-RXL Amp, 7 Terminal, UG, W ZS-00H, ZS-00P U9-O Amp, Terminal, UG, W ZSU MULTIPLE POSITION (HORIZONTAL GANGS) U-X Position, 00 Amp / Pos., Terminal, W, OH/UG ZS CT ENCLOSURES AND SOCKETS UC7-O Amp, 8 Terminal, Transformer Rated, Prewired with Test Switch ZS-0-S UC7-O Amp, Terminal, Transformer Rated, Prewired with Test Switch ZS-0-9S CONDOMINIUM METER BANKS U-RXL Position, Amp / Pos., Terminal, Not Bussed U8-X Position, Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, Amp / Pos., Terminal, 00 Amp Main Bus Rating U88-RXL Position, 00 Amp / Pos., Terminal, Not Bussed U8-X Position, 00 Amp / Pos., Terminal, 0 Amp Main Bus Rating U8-X Position, 00 Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, 00 Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, 00 Amp / Pos., Terminal, 00 Amp Main Bus Rating U8-X Position, 00 Amp / Pos., Terminal, 00 Amp Main Bus Rating MOBILE HOME U-O-00S Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions U-O-00S Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions U-O-00S/ Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions, K AIC Rated U7-O-00S Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions U7-O-00S Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions U7-O-00S/ Position Pedestal, 00 Amp / Pos., Terminal, Circuit Breaker Provisions, K AIC Rated ACCESSORIES MISCELLANEOUS Conduit & Ampacity Information Energization of Electrical Equipment Additional Milbank Products
4 LOGIC LOGIC
5 0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS U800 (No deadfront required) U80 PROFILE Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements in the NEC and also complies with article 0- in the NEC. To insure the safest conditions, we designed our disconnect pullers to be removable or they may be reinstalled in the off position. Another safety feature is the padlock provision on the front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state of the art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, non-fading finish. TECHNICAL INFORMATION U80 0 & 0 AMP FUSIBLE / NON-FUSIBLE AIR CONDITIONER DISCONNECTS AMP TYPE MAX H.P. WT. # 0 FUSIBLE U FUSIBLE U NONFUSIBLE U LINE & LOAD WIRE RANGE GROUND WIRE RANGE DIMENSIONS WIRE RATING CU AL CU/AL D W H CU C AL C #-# AWG #-# AWG #- AWG 9 0 /7 0 #-# AWG #-# AWG #- AWG 9 0 /7 0 #-# AWG #-# AWG #- AWG 8 0 /7 0 /7 U800 is UL Listed without deadfront. Line and load terminations are fully insulated. U80 & U80 std. quantity is per carton. U800 std. quantity is 0 per carton.
6 AC DISCONNECT / SPA BOX Combination AC Disconnect / 0 Amp GFCI Receptacle Together in Box AC DISCONNECT / SPA BOX AMP TYPE U8-0GR MAX H.P. 0 amp, Non-Fused AC Disconnect Duplex 0 amp GFCI Receptacle Type R Enclosure with In-Use Cover WT. # 0 NONFUSIBLE U8-0GR 0 Meets NEC # 0. Requirements * UL Listed as Power Outlet Type R Enclosure In-Use Cover** Duplex Ground Connector Concentric Knockouts AC DISCONNECT, 0 Volt 0 amp, Non-Fused GFCI RECEPTACLE 0 amp LINE & LOAD CONNECTOR WIRE RANGE Reset/Test Button Padlock provision CU AL CU/AL #-# AWG #-# AWG * NEC #0. Heating, Air- Conditioning and Refrigeration Equipment Outlet....The receptacle shall be located on the same level and within 7. m ( ft.) of the heating, airconditioning and refrigeration equipment. * NEC #0.08 Ground-Fault Circuit Interruptor protection for personnel. GROUND CONNECTOR WIRE RANGE DIMENSIONS WIRE RATING #- AWG D W H CU C AL C /7 0 /7 To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position. All units are designed with a padlock provision on the cover for security. **Note: U8-0GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle). *Reprinted with permission from NFPA 70-00, National Electrical Code, Copyright 00, National Fire Protection Association, Quincy, MA 09. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Hot Tub Disconnect or Sub Panel Breaker Enclosure Type R Spa Box with GFCI Protection U88-O-0GB 0 volt ground fault protection UL listed, Type R rainproof Milbank reliability Easy installation pole, 0 amp GFCI breaker protection Compact size: 8-/ H x 7-/ W x -/ D or wire installation, 0 / 0 VAC Standard package of extra one-pole breaker spaces 00 amp overall rating Sub Panel Breaker Enclosure Use as a 00 amp, circuit sub panel enclosure U88-O has provision for () -pole or () -pole small frame breakers AMP 0 0 TYPE WT. # BREAKER PROVISION U88-O 7 BREAKER BREAKER U88-O-0GB U88-O-0GB 8 8 LINE & LOAD CONNECTOR WIRE RANGE GROUND CONNECTOR WIRE RANGE CU AL CU/AL #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 #-/0 DIMENSIONS D W H
7 / 00 AMP & TERMINAL-RINGLESS 00 VAC U787-O-TG U70-RL-TG U700-RL-TG / 00 AMP & TERMINAL-RINGLESS 00 VAC AMP TERMINAL RINGLESS DTE NO. SERVICE HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS D W H CONCENTRIC K.O. S ZSW-00 UG U787-O-TG BLANK #-/0 #-/ AMP TERMINAL RINGLESS DTE NO. SERVICE HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS D W H CONCENTRIC K.O. S ZS-00 OH U70-RL-TG H.O. #-0 kcmil #-0 kcmil 8 8, ZS-00 ZSU-00 OH UG U700-RL-TG* H.O. #-0 kcmil #-0 kcmil 8, FIFTH TERMINAL: For field mounted fifth terminal order catalog number T8K for amp unit. For 00 amp units, order KT. CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral. *UNDERGROUND SERVICE: A closing plate must be used when the U700-RL is used for underground service. Order closing plate catalog number A7 as extra. For overhead service, order hub separately. See page. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 7
8 8 00 AMP & 7 TERMINAL RINGLESS JAW CLAMPING LEVER 00 VAC 00 AMP & 7 TERMINAL RINGLESS JAW CLAMPING LEVER 00 VAC DTE NO. AMP SERVICE U980-RXL DIMENSIONS D W H HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K AMP TERMINAL RINGLESS W HUB CONNECTORS CU/AL LINE LOAD N/A 00 OH/UG U980-RXL C.P. #-0 kcmil #-0 kcmil U970-RXL CONCENTRIC K.O. S, 00 AMP 7 TERMINAL RINGLESS W DTE NO. AMP SERVICE HUB CONNECTORS CU/AL LINE LOAD DIMENSIONS D W H CONCENTRIC K.O. S ZS-00H ZS-00P 00 OH UG U970-RXL C.P. #-0 kcmil #-0 kcmil 7 8 9, HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. INSULATED NEUTRAL: For field installed insulated neutral for the U970 order kit number K07. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 8
9 0 AMP TERMINAL RINGLESS JAW CLAMPING LEVER 00 VAC 9 DTE NO. ZSU-0 AMP SERVICE U9-O 0 AMP TERMINAL RINGLESS W HUB CONNECTORS CU/AL LINE LOAD 0 UG U9-O BLANK /8 - STUDS /8 - STUDS DIMENSIONS D W H CONCENTRIC K.O. S HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: For connector kits, order as extra K0 (twin 0) or K0 (single 00). Separate kits are required for line and load. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K8., 0 AMP TERMINAL RINGLESS JAW CLAMPING LEVER 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 9
10 0 00 AMP/POSITION TERMINAL HORIZONTAL GANG 00 VAC 00 AMP/POSITION TERMINAL HORIZONTAL GANG 00 VAC DTE NO. ZS-00 NO. OF POS SERVICE HUB CONNECTORS CU/AL LINE U-X 00 AMP/POSITION TERMINAL RINGLESS W LOAD DIMENSIONS D W H CONCENTRIC K.O. S OH/UG U-X C.P. /8 - STUDS #-0 kcmil 8,,, HUBS: For proper hub selection see the hub suffix chart on the accessory page. FIFTH TERMINAL: For field mounted fifth terminal in the 9 o clock position, order catalog number KT. CONNECTORS: Extruded aluminum connectors are tin plated. BUSSING: Bussing is / x aluminum. AMPS: Rated 00 amp per position / 00 amp overall. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog. 0
11 0 AMP 8 & TERMINAL TRANSFORMER RATED TEST SWITCH PROVISION 00 VAC DTE NO. ZS-0-S ZS-0-9S UC7-O- NOTE: Picture is NOT shown with DTE-specified wiring configuration. NO. OF TERMS PIECE COVER RINGLESS WITH PREWIRED TEST SWITCH HUB CONNECTORS CU DIMENSIONS D W H CONCENTRIC K.O. S 8 UC7-O-0 BLANK # - # MAX 8 0 UC7-O- BLANK # - # MAX 8 0 CONNECTORS: Units are supplied with sleeve type connectors (# max).,, 0 AMP 8 & TERMINAL TRANSFORMER RATED TEST SWITCH PROVISION 00 VAC Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
12 CONDOMINIUM METER BANKS CONDOMINIUM METER BANKS NO. OF POS. NO. OF POS. U-RXL U8-X U8-X U8-X U8-X MAIN BUS RATING NOT BUSSED 00 AMP 00 AMP MAIN BUS RATING 00 AMP LINE CONNECTOR SIZE #-/0 AWG */8 - STUD */8 - STUD LINE CONNECTOR SIZE */8 - STUD VERTICAL NO. OF POS. U8-X-/ (Order circuit breakers as extra) AMP/POSITION 00 AMP/POSITION RECTANGULAR NO. OF POS. U88-RXL U8-X U8-X MAIN BUS RATING NOT BUSSED 0 AMP 00 AMP AMP/POSITION 00 AMP/POSITION U8-X MAIN BUS RATING 00 AMP LINE CONNECTOR SIZE #-0 AWG */8 - STUD */8 - STUD LINE CONNECTOR SIZE */8 - STUD U8-X 00 AMP */8 - STUD U8-X 00 AMP */8 - STUD U8-X 00 AMP */8 - STUD U8-X 00 AMP */8 - STUD CONNECTOR KITS * SIZE SINGLE TWIN SUFFIX -K -K -K -K KIT K9 K0 K0 K COMPATIBLE WITH U8- U8- U8- U8- U8- U8- U8- WIRE RANGE #-0 kcmil #-00 kcmil #-0 kcmil #-00 kcmil *CONNECTORS: For line wire connector kits, order separately. FIFTH TERMINALS: For field mounted fifth terminal order catalog number K8. Order one per meter position (9 o clock position only). BREAKERS: Units have provision for one double pole main per meter position. Breakers not included. Order as extra Milbank type Q or QNR or comparable. Refer to accessories section in back of catalog. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
13 CONDOMINIUM METER BANKS & 00 amp/pos. (single position) VERTICAL amp/pos. (- position) 00 amp/pos. (- position) D D D " U8-X C B " or 8" A C A /" /" E E E C B 8" " or 7" E E E B C 9" or " /" CONDOMINIUM METER BANKS " CONDOMINIUM METERING BANKS RECTANGULAR amp/pos. (, & position) D 00 amp/pos. (, & position) D FIG. A DIMENSIONS CONCENTRIC K.O. 7" or " 9" or " B, CONCENTRIC K.O. C CONCENTRIC K.O. D E HUB OPENING CONCENTRIC K.O. A C A A A A A B " 7/8" C E E E B E E E " 7/8" Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
14 00 AMP MOBILE HOME METER PEDESTALS TERMINAL RINGLESS 0 / 0 VAC 00 AMP MOBILE HOME METER PEDESTALS TERMINAL RINGLESS 0 / 0 VAC U-O-00S UL Listed File E amp maximum, 0/0 V, W. Ringless type meter socket with horn bypass and stainless steel latch. Short circuit withstand rating 0K AIC, for K AIC, order with suffix. Type R construction for durable outdoor use. Milbank grey polyester powder coat finish. Wire terminations accept copper or aluminum conductors. Line & Neutral: () #-0 kcmil per phase. Line Ground: () #-/0. Load (CB): /0 to 00 kcmil per pole. Load Neutral: () #-0 kcmil. Load Ground: () #-/0, () #/. Commercial grade, plug-in main circuit breaker. Available in 00,, 0 & 00 amp. Type UQFP-M. circuit plated copper interior accepts () -pole or () -pole standard plug-in type circuit breakers. Branch circuit rated to amps max. Acceptable manufacturers: Milbank, Cutler- Hammer, GE or Siemens. Factory or field installable receptacle bridge and receptacle / circuit breaker kits available. See accessories below. SINGLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) U-O-00S UQFP-M Circuit 8 U-O-00S UQFP-M Circuit 8 U-O-00S/* UQFPH-M Circuit 8 DOUBLE PEDESTAL # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs) U7-O-00S () UQFP-M-00 Series 00 Circuit U7-O-00S () UQFP-M-00 Series 00 Circuit U7-O-00S/* () UQFPH-M-00 Series 00 Circuit RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (Sold separately) # RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATION K R Duplex 0 amp, Pole Awg K00-0GR -0R Duplex GFI 0 amp, Pole Awg GFI Rec. K00-TT0 TT0R 0 amp, Pole 0 Awg K R 0 amp, Pole 8 Awg * K00-BRIDGE-POS Self-grounded one position receptacle bridge with hardware K00-BRIDGE-POS Self-grounded two position receptacle bridge with hardware K Stabilizer foot with hardware K0 Pad mount kit with hardware (see note below) KT th terminal for or 9 o clock position K9 Wire kit to convert series wired main breaker to parallel A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available. Consult factory for factory-installed receptacle kits. Receptacle / circuit breaker kits include receptacle, circuit breaker, wire, cover plate and mounting screws. Receptacle bridge K00-BRIDGE-POS or K00-BRIDGE-POS not included with pedestal. Order separately. Pedestals are stocked with series wired main circuit breakers. Order K9 kit to field convert to parallel main lug circuit breaker. For parallel wired main circuit breakers, change S suffix to P (Ex.: U-O-00P). K Stabilizer Foot sold separately. Recommended for double pedestals. Pad mount pedestals available. Order U8 (single meter) or U9 (double meter) prefix. K0 pad mount kit required. Order separately.
15 ACCESSORIES INTERCHANGEABLE UNIT HUBS HUB ADAPTER PLATE (Converts opening to opening) S8 SMALL RL"OPENING (STANDARD) SUFFIX WL YL ZL DL EL SIZE MILBANK NO. A7 A7 A7 A77 A78 LARGE R OPENING (HEAVY DUTY) SUFFIX F G H SIZE MILBANK NO. A80 A8 A8 REMOVABLE HUB CLOSING PLATE DESCRIPTION SUFFIX CAT. # STANDARD (for -RL opening) LARGE (for -R opening) -XL A7 -X A90 ACCESSORIES CLOSING COVERS METAL CLOSING PLATE (for ringless sockets) CP- HUB SUFFIX CHART O Plain Top WL For -RL Opening RL Small Hub Opening YL For -RL Opening R Large Hub Opening ZL For -RL Opening XL Small Closing Plate DL For -RL Opening X Large Closing Plate EL For -RL Opening Large Hub Opening F For -R Opening RXL adapted to small Closing Plate G For -R Opening RRL Large Hub Opening adapted to small Hub Opening H For -R Opening METER CLOSING PLATE (Grey Plastic) 00 FOR CONDO METERING BANKS (-00 AMP) K8 FIFTH TERMINALS PLUG-IN FIFTH TERMINAL T8K (Fits in round hole of old style block) HEAVY DUTY JAW CLAMPING K8 HEAVY DUTY JAW CLAMPING K8 FIFTH TERMINAL KT (Fits in square hole of new style 00 amp block) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
16 ACCESSORIES SINGLE CONNECTOR KITS For use with /8 - stud type units only TWIN DISCONNECT SLEEVE M- ACCESSORIES SUFFIX K K KL SUFFIX K K7 # K9 K0 K0L # K08 K ( per set) -0 kcmil -00 kcmil or () /0-0 kcmil -00 kcmil or () /0-0 kcmil Non-rotating ( per set) -0 kcmil -00 kcmil or () /0-0 kcmil SUFFIX K KL K SUFFIX Replaces the load side slide-in nut assembly on Milbank 00 amp sockets. Allows for a 00 amp tap location in addition to the #-0 kcmil load-side connector. K0 Includes Safety Barrier Extensions for applications over 00 VAC. K977-INT INTERNAL HEX K0-INT INTERNAL HEX K K8 # K0 K0L K # K K08 ( per set) -0 kcmil -0 kcmil Non-rotating -00 kcmil ( per set) -0 kcmil -00 kcmil LOAD TAP CONNECTORS ( per set) AMPS PLUG-IN BREAKER COMPATIBILITY CHART CUTLER-HAMMER SIEMENS (WESTINGHOUSE) (ITE) SIEMENS MURRAY / CROUSE-HINDS G.E. SQ-D -00 HQP / BR / WBJ Q / QN MD Q LINE 00 QUICKLAG P / BR / HQP QP MP Q LINE HOMELINE ISOLATED NEUTRAL KIT K07 MILBANK -POLE 00 AMP LARGE FRAME 0K AIC & K AIC AMPS 0K AIC PLUG-IN K AIC PLUG-IN 0K AIC PLUG-IN K AIC PLUG-IN 0K AIC BOLT-ON K AIC BOLT-ON 0K AIC BOLT-ON 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X UQFP- UQFPH- UQFP-M- UQFPH-M- UQFB- UQFBH- UQFB--X 0 UQFP-0 UQFPH-0 UQFP-M-0 UQFPH-M-0 UQFP-0 UQFBH-0 UQFP-0-X 7 UQFP-7 UQFPH-7 UQFP-M-7 UQFPH-M-7 UQFB-7 UQFBH-7 UQFB-7-X 00 UQFP-00 UQFPH-00 UQFP-M-00 UQFPH-M-00 UQFB-00 UQFBH-00 UQFB-00-X Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment in this catalog.
17 CONDUIT AND AMPACITY INFORMATION 7 MAXIMUM OF CONDUCTORS IN CONDUIT* TYPE RHW & RHH (without outer covering) THW CONDUCTOR SIZE AWG,MCM 0 8 CONDUIT TRADE SIZES (INCHES) TW THW FEPB ( thru ), RHW and RHH (without outer covering) RH, THHW 0 0 /0 /0 /0 / *This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C. * ALLOWABLE AMPACITIES OF INSULATED COPPER & ALUMINUM CONDUCTORS (W IN CONDUIT) 7 C (7 F) A /0 /0 /0 / *CU B AL or CU-Clad AL A 0 8 /0 /0 /0 / C A = Size: AWG/MCM B = Ampere Rating for Insulation Types: FEPW, RH, RHW, THW, THWN, XHHW, USE, W. C = Ampere Rating for Insulation Types: RH, RHW, THW, THWN, XHHW, USE (Per NEC table 0-) AMBIENT TEMP.C CORRECTION FACTOR AMPACITY CORRECTION FACTORS AMBIENT TEMP.F Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 99 N.E.C. Manual article 0- and ANSI / UL- (except where restricted by line connector size.) These requirements provide for a diversity factor / demand factor being utilized in determining the overall (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed these diversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and non UL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are based on the meter socket being wired with 7 C insulated wire conductor, sized in accordance with Table 0- of the National Electric Code. GANG SOCKET OVERALL AMPACITIES NO. OF METER POSITIONS 00A / POS. AMPACITY 00A 00A 00A A 70A A / POS. AMPACITY 00A A 0A 8A 0A 0A / POS. AMPACITY 00A A 70A 8A 9A 00A / POS. AMPACITY 00A 70A 0A 0A 8A CONDUIT AND AMPACITY INFORMATION Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk ( ) shall not exceed amps for AWG, 0 amps for AWG, and 0 amps for 0 AWG copper: or amps for AWG and amps for 0 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. All meter sockets are 00 Volt rated unless otherwise noted. All meter socket ampacity ratings are continuous duty unless otherwise noted. 7
18 8 ENERGIZATION OF ELECTRICAL EQUIPMENT IMPORTANT NOTE In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. BEFORE ENERGIZING ENERGIZATION OF ELECTRICAL EQUIPMENT A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. ) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. ) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. WHEN ENERGIZING A. Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. ) Take action to prevent/decrease damage to property in the event of failure of the installation. ) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. AFTER ENERGIZING A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. RECOMMENDED TORQUE FOR GENERAL APPLICATIONS* NOMINAL JOINT DESCRIPTION HEAD TYPE TORQUE SIZE SCREW NUT ( INCH LBS. ) / / / BRASS STEEL STEEL STEEL STEEL STEEL STEEL STEEL Brass Nut or Extruded Hole CU or AL Busbar </8 Steel Nut or EH; CU or AL Busbar >/8 Aluminum Extruded Hole Steel Nut or Extruded Hole Aluminum Extruded Hole Steel Nut or EH; CU or AL Busbar Aluminum Extruded Hole ALL ALL ALL ALL ALL ALL ALL HEX 0- in. lbs. -0 in. lbs 0- in. lbs 0- in. lbs 0-0 in. lbs. 0-0 in. lbs. 0-0 in. lbs in. lbs. / STEEL Steel Nut or EH; CU or AL Busbar HEX 00-0 in. lbs. /8 STEEL Steel Nut HEX 0-00 in. lbs. / STEEL Steel Nut HEX 00-0 in. lbs. *Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. EH: Extruded Hole CU: Copper AL: Aluminum 8
19 ADDITIONAL MILBANK PRODUCTS 9 Other quality products available from Milbank ADDITIONAL MILBANK PRODUCTS In addition to your local utility s meter mounting equipment, Milbank also manufactures supporting products, such as... Air Conditioner Disconnects Hot Tub Disconnects RV/Mobile Home Power Outlets Terminal Boxes Temporary Power Outlets Commercial Pedestals Commercial Enclosures CT Enclosures Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches Contact your local distributor or go to to find additional product literature. 9
20 Meter Mounting Equipment & More! Commercial Electrical Enclosures Residential & Commercial Metering Commercial Meter Pedestals Disconnect Devices Current Transformer Enclosures RV/MH Pedestals Temporary Power Outlets Circuit Breakers Distribution Unit Substations Enclosed Circuit Breakers Safety Switches Test Switches REPRESENTATIVE Young and Champagne Co. 700 Intervale Ave Detroit, MI 88 Tel: Fax: MILBANK MFG. CO. PO Box 908 Kansas City, MO -008 Tel: 8-8- Fax: Toll Free: DTE /0 (K)
Meter Mounting Equipment. Northern Indiana Public Service Co.
Meter Mounting Equipment Northern Indiana Public Service Co. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert F. Waldrop, 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop
More informationMeter Mounting Equipment Florida Area Catalog
Meter Mounting Equipment Florida Area Catalog Look for FMG APPROVED for equipment approved for use on Florida Meter Group lines. MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin Robert
More informationMeter Mounting Equipment Wisconsin Area
Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman
More informationNew England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
New England Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides the tools that
More informationMEG Approval Meter Equipment Group
MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationWisconsin Area Catalog
Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationMeter Mounting Equipment Commonwealth Edison
Meter Mounting Equipment Commonwealth Edison MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice
More informationDuke/MEG Approval Meter Equipment Group
Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At
More informationIndiana Meter Mounting Equipment
Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationComEd Service Area Meter Mounting Equipment
ComEd Service Area Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs
More informationREC Municipal Meter Mounting Equipment
REC Municipal Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationMeter Mounting Equipment. GA/AL/FL Panhandle Area
Meter Mounting Equipment GA/AL/FL Panhandle Area 2 MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-966 Bill Martin Robert F. Waldrop, 922-2002 Robert F. Waldrop, II Chairman Katrina Waldrop Henke
More informationOhio Meter Mounting Equipment
Ohio Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures
More informationMeter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market
Meter Mounting Equipment Arkansas, W. Tennessee, N. Mississippi Market MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman
More informationMeter Mounting Equipment
Meter Mounting Equipment Central Hudson Service Area New York State Electric & Gas Service Area National Grid NY Service Area Rochester Gas & Electric Service Area MILBANK OVERVIEW MILBANK OVERVIEW Charles
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area U80 PROFILE U8 Milbank s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Our compact design meets all wire bending space requirements
More informationMeter Mounting Equipment Colorado Area
Meter Mounting Equipment Colorado Area milbank overview milbank overview Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. aldrop, 9-00 Robert F. aldrop, II Chairman Katrina aldrop Henke Vice Chairman
More informationNew Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment
New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com Milbank Overview Energy At Work
More informationLouisiana/Mississippi. Area Catalog
Louisiana/Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions
More informationPennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog
Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy
More informationDTE Energy Area Catalog and Consumers Energy Multi-Position Sockets
DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.483.534 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy
More informationRecreational Vehicle Park Electrical Products & Accessories
Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationFlorida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com
Florida Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationLouisiana & Mississippi Area Catalog
Louisiana & Mississippi Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationTennessee Area Meter Mounting Equipment
Tennessee Area Meter Mounting Equipment MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,
More informationUpstate New York Meter Mounting Equipment
Upstate New York Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.483.534 milbankworks.com MILBANK OVERVIE Milbank Overview Energy At ork since 97 Milbank builds
More informationtot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,
' Stock ',,' ' ' ' *t *«W'-' tt M.. '. #*. ;, '. ''"' f* " ' '-', *
More informationAmeren Service Area Product Catalog
Ameren Service Area Product Catalog MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 6420 877.48.54 milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 927 Milbank builds solutions
More informationPSE&G Long Island Meter Mounting Equipment
PSE&G Long Island Meter Mounting Equipment Milbank Overview Energy At Work since 927 3 MILBANK OVERVIEW Milbank designs and manufactures electrical solutions that move and manage power for the residential,
More informationConsolidated Edison Orange & Rockland Meter Mounting Equipment
Consolidated Edison Orange & Rockland Meter Mounting Equipment 2 MILBANK OVERVIE Milbank Overview Energy At ork since 1927 Milbank designs and manufactures electrical solutions that move and manage power
More informationNew York City Apartment Metering Meter Sockets / Load Centers
s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,
More information6.2. Power Pedestals. Contents
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More information5.2. Power Pedestals. Contents Description
.2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............
More informationContents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at
-1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION
More informationContents. Volume 1 Residential and Light Commercial CA E December
Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................
More informationEquipment. Metering. Metering Equipment 1. Contents
1 July 00 Utilities Servicing Upstate New York Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Niagara Mohawk (NIMO) Utility.................................
More informationMetering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS
Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS REVISED FEBRUARY 2017 TABLE OF CONTENTS Metering Equipment & Installation Standards... 1 Metering Equipment & Installation Standards
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationEquipment. Metering. Metering Equipment 1. Contents
1 May 00 Utilities Servicing Ohio Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility Dayton Power & Light (DP&L)...................................
More informationMP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers
Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed
More informationRMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities
RMTR-11HOU Meter Mounting & Distribution Equipment Houston Area Utilities History Cooper B-Line Meter Mounting History Cooper B-Line, a leading global manufacturer, purchased Circle AW in 1993. We continue
More informationIntroduction. Upon completion of Basics of Meter Mounting Equipment
Table of Contents Introduction...2 Power Distribution...4 Single-Position and Gang Meter Sockets...9 Meter Combos...27 Overcurrent Protection Device Ratings...38 Uni-Pak Metering...41 Power Mod Modular
More informationMultiple Metering, Horizontal Gang - Non Lever Bypass
Multiple Metering, Horizontal Gang - Non Bypass 100 Amp & 200 Amp Continuous per Position - 600 VAC Application 2-6 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground
More informationDISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual
POWER PROTECTION Series 600 UPS Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz Installation Manual TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.............................................1 1.0
More informationThe Reliable Choice. Field Pocket Guide
The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,
More informationSelection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting
Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information -
More informationMultiple Metering, Vertical Gang
Multiple Metering, Vertical Gang Non 100 Amp Continuous - 600 VAC 200 Amp / 100 Amp Owner s Loop - 600 VAC Application 2-3 meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationSECTION 500 METERING AND ASSOCIATED EQUIPMENT
SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.
More information10 Commercial, Industrial, Agricultural Services
10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three
More informationSelection and Application Guide For use in New England EQUIPMENT
Selection and Application Guide For use in New England EQUIPMENT s Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3 -- 7 Residential, 1 Phase, 3 Wire, 3 Phase,
More information6.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description....................................
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More information9. Non-Residential Services (Commercial, Industrial, and Agricultural)
Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect
More informationPower Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description....................................... Application Description.....................................
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationMetering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering
Metering Products and Meter Breaker Family.1 Meter Sockets Single Meter Sockets...................................... Commercial Lever Bypass Sockets........................... Multiple Position Horizontal
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationModular Metering Application Guide
GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III
More informationCustomer Requirements Meter Socket Configurations
Application Information on meter socket configurations available from Tacoma Power. For enclosed meter pedestals, see standard C-MR-0020 Customer Requirements, Enclosed Meter Pedestal. General Requirements
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationSection 4 Square D QO Loadcentres
Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and
More informationSelection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting
Selection and Application Guide For use in Arkansas, Oklahoma & Texas meter mounting Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase,
More informationPower Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2
Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels. Introduction Product Description............................................. Application Description...........................................
More informationVolume 1 Residential and Light Commercial CA E December
Power Pedestals Power Pedestals Construction Site and RV Parks Marina Power and Lighting Mobile Home Panels.1 Introduction Product Description............................................. 28 Application
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationCABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum
PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationAccessories. Accessories. Meter Mounting Equipment
Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim
More informationStandard switch modules (type WS) are designed for flexibility, space savings, & durability.
Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More information10. METERING General Requirements
10. METERING 10.1 General Requirements A. The Company will not supply service to a Customer whose wiring is designed for resale of electricity through submetering except for recreational campgrounds, marinas,
More informationGroup Meter Main - Without Bypass
100 Amp Vertical 2012 MS60 (closed) 2012 MS60 (open) Application For vertical multi-meter/mains installations - 6 position maximum 225A and 400A main buss Main breaker provisions - breakers not included
More informationCT Metering. CT Metering. Meter Mounting Equipment
Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationIndianapolis Power & Light Company
Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationMP Meter-Pak Meter Centers
Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application
More informationCON EDISON EQUIPMENT
CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More informationMicrolectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units
Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric
More informationPART A General Conductor Requirements
PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND
More informationModular Metering Construction Details
GE Consumer & Industrial Electrical Modular Metering Construction Details Contents Meter Mod III Main Breaker Module, Single Phase, Top or Bottom Feed...........................1 Main Switch Module, Single
More informationTemporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
More information(CT, NH, ME, RI, VT, MA)
Selection and application guide For use in New England States (CT, NH, ME, RI, VT, MA) Meter Mounting Equipment www.talonmetering.com 1 Meter Mounting Equipment Table of Contents Service Rating Positions
More informationINSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH
INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by
More informationModular Metering. Canadian Version
Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationPower Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module
Type WC House Power Module 06/01/13 WC Series House Power Module Power Mod s patented WC family of house power modules offers the ability to combine power distribution to branch circuits within a module
More informationfastfax Rock Solid TM Load Centers General Information
General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More information