Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Size: px
Start display at page:

Download "Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014"

Transcription

1 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits PowerMark Gold Load Centers Product Features and Benefits PowerMark Gold and Plus Load Centers Product Number Guides Q-Line Plug-in Circuit Breakers Special Purpose Circuit Breakers PowerMark Gold and Plus Single-Phase Load Centers Main Lug Convertible to Main Breaker Main Breaker Factory Installed PowerMark Plus Three-Phase Load Centers Main Circuit Breakers or Main Lugs Factory Installed PowerMark Gold Load Centers Specialty Panels PowerMark Gold Meter Socket Load Centers Field Installed Accessories Wiring Diagrams Load Centers and Meter Socket Load Centers Knockouts BuyLog Catalog 1-1

2 Q-Line Circuit Breakers Reliability and Economy Special Purpose Circuit Breakers PowerMark Gold Main Circuit Breakers Arc Fault Circuit Interrupter CB3 Ground Fault Circuit Interrupter Switching Neutral HID Lighting Breaker High Magnetic Breaker Molded Case Switch Surge Arrester TQ Breaker Copper stabs, tin-plated for corrosion resistance, make the connection reliable and permanent. Heat-resistant thermoset cases and covers add stability and structural rigidity. Trips are easy to spot because handles trip to the center position. The dedicated calibration screw is cemented (not simply papered over) to prevent shifting. The result is stable calibration for optimum trip performance. At 1/2, THQP breakers are half the width of standard breakers, permitting the use of smaller load centers that save money and space in both new construction and service upgrades. They feature the same high-performance design, and meet the same stringent standards as other Q- Line breakers. Our 1 THQL will remain the breaker of choice for many contractors. In applications where space and cost are not critical, they re an excellent choice. But when size and money are driving considerations, THQP breakers are the smart choice. Enclosed circuit breakers make it easy and efficient to install exterior main breakers. Maximum protection against all-too-common electrical fires comes from the new technology built into GE s arc fault circuit interrupters (AFCIs). With its ability to detect and interrupt arcing caused by damaged wire insulation or a frayed extension cord, the AFCI takes home and family protection to a new, higher level. THQLSURGE surge arresters are easy to install and protect the whole house computers, fax machines, televisions, stereos, VCRs and other sensitive electronic equipment from destructive surges. The NEC requires ground fault protection of receptacles outdoors and in garages, bathrooms and spa areas. These ground fault circuit interrupters eliminate the need for separate GFCI receptacles, protect against short circuits and overloads, and prevent shock by detecting very low levels of current leaks and immediately shutting off power to the circuit. 1-2 BuyLog Catalog

3 PowerMark Gold Load Centers Highest Quality and Convenience PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. UL Listed (Panelboards No. 67) Suitable for Use as Service Entrance Equipment when installed in accordance with National Electrical Code 60 C/75 C Conductor Rating Single phase, A, 2-42 circuits Main lug models field convertible to main breaker Main breaker 22kAIC standard - factory installed All load centers top or bottom feed Indoor and outdoor rated enclosures Indoor fronts combination surface/flush Copper bus with tin plating standard 1 Split neutrals extend the full length of the interior for ease of wiring Entire main lug line converts easily to main breaker Combination surface/flush front with spring-reinforced pan Combination slotted/robertson square-drive screws on neutral, 2 ground, front and breaker lugs Front packed in inner carton for added protection Field installable feed-through lugs up to 200A Straight-through main wiring Main breaker is clearly marked and circuit numbers are stamped on front Isolated ground bar is available Compact box maintains optimum wire-bending space One-piece interior removes and reinstalls easily Full-length neutrals are easier to wire, 2 reducing installation time and cost Minimum 100% neutral terminations Sturdy copper bus and galvanized box increase durability and reliability Accepts GE Q-Line branch circuit breakers, including GE s exclusive 1/2" THQPs Main breaker configuration allows top or bottom feed without modification Combination slotted/robertson square-drive speeds screw wiring All holes rated for 14-4 wire 100% rated split neutral on each side 2 Tie bar may be removed to split neutral/ground Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site. A complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. The PowerMark Gold line includes a wide range of outdoor as well as indoor units. Accessories and Options Door lock and handle Equipment ground kits Sub-feed and feed-thru lugs Front filler plates Handle lock and ties Main lug load centers offer an economical solution for subpanels and similar applications. All main lug units 125A and above convert easily to main breaker. Hardware kits Main breaker retainers Neutral kits Universal raintight hubs 1 Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs circuit and above. GE s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kAIC ratings, and all the accessories needed to complete the job. Safety accessories convenient and easy to install THQLSURGE whole house surge protector Arc fault circuit interrupter breaker, 1- or 2-pole Ground fault circuit interrupter breaker, 5mA and 30mA Generator transfer panel 30A or 60A, indoor or outdoor GE AC disconnects BuyLog Catalog 1-3

4 PowerMark Gold and Plus Load Centers Product Number Guides Product Number Guide for Load Centers (Product number for illustrative purposes only) T M C CU B GE Identification Type M = Main breaker L = Main lug LM = Convertible PL = Main lug (Thermoplastic) Maximum Number 1" Spaces 2, 4, 6 42 Insert for 3-Phase 4-Wire Load Centers Insert for Specials G or T = Factory installed ground bar B = feed main breaker FL = Factory installed feed-through lugs D = Optional door for 6-8 circuit panel. (Doors standard on all units 12 circuits or greater) W = White Front Insert for PowerMark Gold CU = Copper Bus 42 = Copper Bus Full 42 circuit panel Enclosure Type C = Combination surface/flush F = Flush S = Surface R = Outdoor Bus Ampere Rating 40 = 40 Amps 20 = 200 Amps 70 = 70 Amps 22 = 225 Amps 10 = 100 Amps 30 = 300 Amps 12 = 125 Amps 40 = 400 Amps 15 = 150 Amps 60 = 600 Amps Product Number Guide for Q-Line Plug-in Circuit Breakers (Product number for illustrative purposes only) T H QL 1 1* 15 GF GE Identification Interrupting Rating H = 10kAlC HH = 22kAlC X = 65kAlC Type QL = 1" plug-in QP = 1/2" plug-in QB = 1" bolt-on Poles (1, 2, 3) Voltage 1 = 120/240V 2 = 240V Ampere Rating Ground Fault/Arc Fault Circuit Interrupter GF = 1-pole Ground Fault Circuit Interrupter 5 ma GF1= 2-pole Ground Fault Circuit Interrupter 5 ma AF = 1- & 2-pole Arc Fault Circuit Interrupter AF2 = 1- & 2-pole Combination Arc Fault Circuit Interrupter GFEP = 1- & 2-pole Ground Fault Circuit Interrupter 30 ma GF3 = 1- & 2-pole self-test Ground Fault Circuit Interrupter - 5 ma *Omit character for THQP breakers, which are all 120/240V. 1-4 BuyLog Catalog

5 Q-Line Plug-in Circuit Breakers UL Listed (Molded Case Circuit Breakers No. 489) Federal Government Specification Qualified (WC-375B) 60 C / 75 C Conductor Rating Quick Make, Quick Break Box Type Terminals Q-Line Plug-in Circuit Breakers Specifications THQP130 THQP230 THQL1120 Wire Size AWG/kcmil 1 Breaker Type Ampere Rating Cu Al THQP THQL THHQL /0 4-1/0 TXQL /0 2-2/0 1 Solid or stranded for AWG THQL2140 THQL32015 Q-Line Plug-in Circuit Breakers 10,000AIC 22,000AIC 65,000AIC Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module 120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac Ampere Product Product Product Product Product Product Rating Number Number Number Number Number Number Single Pole THQP115 THQL1115 THHQL1115 TXQL THQP120 THQL1120 THHQL1120 TXQL THQP125 THQL1125 THHQL1125 TXQL THQP130 THQL1130 THHQL1130 TXQL THQP135 THQL1135 THHQL THQP140 THQL1140 THHQL THQP145 THQL1145 THHQL THQP150 THQL1150 THHQL1150 Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10 Two-Pole 3 : Incorporates Internal Common Trip Bar 15 THQP215 THQL2115 THQL THHQL2115 THHQL TXQL THQP220 THQL2120 THQL THHQL2120 THHQL TXQL THQP225 THQL2125 THQL THHQL2125 THHQL TXQL THQP230 THQL2130 THQL THHQL2130 THHQL TXQL THQP235 THQL2135 THQL THHQL2135 THHQL THQP240 THQL2140 THQL THHQL2140 THHQL THQP245 THQL2145 THQL THHQL2145 THHQL THQP250 THQL2150 THQL THHQL2150 THHQL THQL2160 THQL THHQL2160 THHQL THQL2170 THQL THHQL2170 THHQL THQL2180 THQL THHQL2180 THHQL THQL2190 THQL THHQL2190 THHQL THQL21100 THQL THHQL21100 THHQL THQL21110 THHQL THQL21125 THHQL21125 Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 Three-Pole 3 : Incorporates Internal Common Trip Bar 15 THQL32015 THHQL32015 TXQL THQL32020 THHQL32020 TXQL THQL32025 THHQL32025 TXQL THQL32030 THHQL32030 TXQL THQL32035 THHQL THQL32040 THHQL THQL32045 THHQL THQL32050 THHQL THQL32060 THHQL THQL32070 THHQL THQL32080 THHQL THQL32090 THHQL THQL32100 THHQL32100 Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3 1 UL Listed as HACR (heating, air conditioning and refrigeration). 2 UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads amp UL Listed as HACR (heating air conditioning and refrigeration). 4 Required for three-phase and High Leg Delta Systems only. References: Accessories Pages 1-24 thru 1-29 Auxiliary Switches and Shunt Trips BuyLog pages 6-40 thru BuyLog Catalog 1-5

6 Special Purpose Circuit Breakers 60 C / 75 F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip Page Updated 11 / 2014 Arc Fault 2 UL Listed Arc-Fault Circuit Interrupters No Ampere Rating 1 Pole, 120/240 Volts ac 1 Product Number 15 THQL1115AF2 20 THQL1120AF2 22,000 AIC 15 THHQL1115AF2 20 THHQL1120AF2 Std. Pkg. 10 Cartons of 1 As of Jan. 1, 2008, 2005 NEC requires combination AFCI. 1 Combination AFCI compliant with 2008 NEC and later 2 For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more details on our Arc Fault products. Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker UL Listed (Available December 2014) Ampere Rating 1 Pole, 120 Volts ac Product Number 15 THQL1115DF 20 THQL1120DF 22,000 AIC 15 THHQL1115DF 20 THHQL1120DF Std. Pkg. 10 Cartons of 1 Ground Fault UL Listed Ground Fault Circuit Interrupters No Class A (5 milliamperes ground fault trip level). 1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac 15 THQL1115GF THQL2115GF1 20 THQL1120GF THQL2120GF1 30 THQL1130GF THQL2130GF1 40 THQL2140GF1 50 THQL2150GF1 22,000 AIC 15 THHQL1115GF 20 THHQL1120GF 30 THHQL1130GF Std. Pkg. 10 cartons of 1 10 cartons of 1 Ground Fault Self Testing 3 UL943 Ed5 (5 milliamperes ground fault trip level) 22,000 AIC 1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac 15 THQL1115GF3 THQL2115GF3 20 THQL1120GF3 THQL2120GF3 30 THQL1130GF3 THQL2130GF3 15 THHQL1115GF3 20 THHQL1120GF3 30 THHQL1130GF3 Std. Pkg Check for availability PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load Centers (Includes mounting base) UL Listed. Description Ampere Rating Product Number Lug Size 100 THQMV100D 125 THQMV125D Main Circuit Breaker Kits 150 THQMV150D (cu), 22,000 AIC 175 THQMV175D 2/ THQMV200D 225 THQMV225D Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is converted to main breaker. Arc Fault THQL1115DF THQL1120GF THQMVXXXD 1-6 BuyLog Catalog

7 Special Purpose Circuit Breakers 60 C / 75 F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip Page Updated 11 / 2014 PowerMark Gold Main Circuit Breaker Kit For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical. Description Product Number Main Circuit Breaker Kit - Order appropriate THQL TQMH kAIC or THHQL 22kAIC breakers separately 1 Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2. Equipment Ground Fault UL Listed Ground Fault Circuit Interrupters No milliampere ground fault trip level 1-Pole, 120/240 Volts ac 2-Pole, 120 Volts ac 15 THQL1115GFEP THQL2115GFEP 20 THQL1120GFEP THQL2120GFEP 30 THQL1130GFEP THQL2130GFEP Std. Pkg. 10 Cartons of 1 10 Cartons of 1 Switching Neutral UL Listed. 10kAIC RMS symmetrical. Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole. 1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral 120/240 Volts ac 120/240 Volts ac 15 THQL21WY15 THQL31WY15 20 THQL21WY20 THQL31WY20 25 THQL21WY25 THQL31WY25 30 THQL21WY30 THQL31WY30 Std. Pkg. 5 cartons of 5 5 cartons of 3 "HID" Lighting UL Listed as HID. HID breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HID lamps, are switched on and off. 1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac 15 THQL1115HID 2 THQL2115HID 20 THQL1120HID 2 THQL2120HID 30 THQL1130HID THQL2130HID 22,000 AIC 15 THHQL1115HID 2 THHQL2115HID 20 THHQL1120HID 2 THHQL2120HID 30 THHQL1130HID THHQL2130HID Std. Pkg. 5 cartons of 10 5 cartons of 5 2 UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads. High Magnetic UL Listed. 10kAIC RMS symmetrical High short circuit setting suitable for circuits with inherent high-inrush load currents. Ampere Rating 1-Pole, 120/240 Volts ac Product Number 15 THQL1115HM 20 THQL1120HM 25 THQL1125HM 30 THQL1130HM 40 THQL1140HM 50 THQL1150HM Std. Pkg. 5 cartons of 10 TQMH000 THQL21WY30 THQL2120HID THQL1140HM Prices and data subject to change BuyLog Catalog 1-7

8 Special Purpose Circuit Breakers 60 C / 75 F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip Molded Case Switches UL Listed Without overload or short circuit protection. 2-Pole 3-Pole 120/240 Volts ac 60 TQL21Y TQL21Y Volts ac 60 TQL22Y60 TQL32Y TQL22Y100 TQL32Y100 Std. Pkg. 5 cartons of 5 5 cartons of 3 Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels Two breakers required for interlocking. Poles Ampere Rating Product Number TQ Circuit Breakers 2 30 THQL2130GEN 2 60 THQL2160GEN 3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers. 10 kaic RMS symmetrical 1-Pole 2-Pole 15 TQ1115 TQ TQ1120 TQ TQ1130 TQ TQ1140 TQ TQ1150 TQ TQ2160 Std. Pkg. 1 carton of 10 1 carton of 5 THQL 120/240 Vac, with Factory Installed Shunt 1 # of Ampere 120/240 Vac Poles Rating Wire Range 2 Interrupting Rating Product Number 1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST (1) 14-8 Cu/12-8 Al 10kA THQL1120ST (1) 14-8 Cu/12-8 Al 10kA THQL1130ST (1) 8-3 Cu/8-3 Al 10kA THQL1135ST (1) 8-3 Cu/8-3 Al 10kA THQL1140ST (1) 8-3 Cu/8-3 Al 10kA THQL1145ST (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1 1 Shunt trip requires one additional pole of space. THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt 1 # of Ampere 240 Vac Poles Rating Wire Range 2 Interrupting Rating Product Number Cu/12-8 Al 10kA THQL2115ST Cu/12-8 Al 10kA THQL2120ST Cu/12-8 Al 10kA THQL2130ST Cu/8-3 Al 10kA THQL2135ST Cu/8-3 Al 10kA THQL2140ST Cu/8-3 Al 10kA THQL2145ST Cu/8-3 Al 10kA THQL2150ST Cu/8-3 Al 10kA THQL2160ST /0 Cu/4-1/0 Al 10kA THQL2170ST /0 Cu/4-1/0 Al 10kA THQL2180ST /0 Cu/4-1/0 Al 10kA THQL2190ST /0 Cu/4-1/0 Al 10kA THQL21100ST Cu/12-8 Al 10kA THQL32020ST Cu/12-8 Al 10kA THQL32030ST Cu/8-3 Al 10kA THQL32040ST Cu/8-3 Al 10kA THQL32050ST Cu/8-3 Al 10kA THQL32060ST /0 Cu/4-1/0 Al 10kA THQL32070ST /0 Cu/4-1/0 Al 10kA THQL32080ST /0 Cu/4-1/0 Al 10kA THQL32090ST /0 Cu/4-1/0 Al 10kA THQL32100ST1 2 Solid or stranded for AWG. *Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company. TQL21Y100 TQ1120 THQL1130ST1 THQL2120ST1 THQL32020ST1 1-8 BuyLog Catalog

9 PowerMark Gold and Plus Load Centers Single-Phase, Three-Wire, 120/240 Vac Main Lugs Convertible to Main Breaker Load Center 1PH Main Lug Indoor NEMA 1 Product Features UL Listed (Panelboards No. 67) 60 /75 C Conductor Rating Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For a listing of CSA Listed load centers, visit geindustrial.com. TLM2020CCU TPL412R Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1 1 1/2 1/2 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type 1 Number Cu-Al Ground Kit Number Surface Top 1A 14-4 TGK4 (order separately) TL240SCU 1, Surface Top 1A 6-3 TGK4 (order separately) TL270SCU 1, Combination Top 2A 1-2/0 TGL1 (order separately) TL412C 1,2,8 Flush/Surface Combination Top 2A 1-2/0 TGL1 installed TL412CT 1,2,3,8 Flush/Surface Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C 1,2,3, Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT 1,2,3, Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU 4, Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD 4, Flush Top 3A 6-1 TGL2 installed TLM612FCUDG 4, Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU 4, Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD 4, Surface Top 3A 6-1 TGL2 installed TLM612SCUDG 4, Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU 4, Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD 4, Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU 4, Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD 4, Surface Top 3A 6-1 TGL2 installed TLM812SCUDG 4, Combination Top /0 Included 10 TLM1212CCU 7,8 Flush/Surface White Combo Top /0 Included 10 TLM1212CCUW 7,8,9 Flush/Surface This table continued on next page BuyLog Catalog 1-9

10 PowerMark Gold and Plus Load Centers Single-Phase, Three-Wire, 120/240 Vac Main Lugs Convertible to Main Breaker Load Center 1PH Main Lug Indoor NEMA 1 Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1 1 1/2 1/2 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground Kit Number Combination Top 4 6-2/0 TGK12 and TGK24 TLM1612CCU 5 Flush/Surface (order separately) Combination Top 4 6-2/0 TGK12 and TLK20 TM1612CCUG 7 Flush/Surface installed Combination Top 7 6-2/0 TGK24 and TGK32 TLM2412CCU 5 Flush/Surface (order separately) White Combo Top 7 6-2/0 TGK24 and TGK32 TLM2412CCUW 5,9 Flush/Surface (order separately) Combination Top 7 6-2/0 TGK24 and TLK20 TLM2412CCUG 7 Flush/Surface installed Combination Top TGK32 TLM1620CCU 6 Flush/Surface (order separately) White Combo Top TGK32 TLM1620CCUW 6,9 Flush/Surface (order separately) Combination Top TGK32 TLM1620CCUG 6 Flush/Surface installed Combination Top TGK32 TLM2020CCU 6 Flush/Surface (order separately) White Combo Top TGK32 TLM2020CCUW 6,9 Flush/Surface (order separately) Combination Top TGK42 TLM2020CCUG 6 Flush/Surface installed Combination Top 9 1-3/0 (Cu), TGK24 and TLK32 TLM2420C42 6 Flush/Surface 2/0-3/0 (Al) (order separately) Combination Top (Cu), TGK32 and TLK20 TLM3220C42 6 Flush/Surface 2/0-250 (Al) (order separately) Combination Top TGK32 TLM3220CCU 6 Flush/Surface (order separately) White Combo Top TGK32 TLM3220CCUW 6,9 Flush/Surface (order separately) Combination Top TGK42 TLM4020CCU 6 Flush/Surface (order separately) White Combo Top TGK42 TLM4020CCUW 6,9 Flush/Surface (order separately) Combination Top (Cu), TGK42 TLM4220CCU 6 Flush/Surface 2/0-300 (Al) (order separately) Combination Top (Cu), TGK42 TLM4222CCU 6 Flush/Surface 2/0-300 (Al) (order separately) 1 No door 10 kaic amp maximum branch capacity. 4 For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max. 5 For main breaker, order TQMH000. See page Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page For main breaker, order THQMVXXXD circuit breaker from page For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28). 8 No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required. 9 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590) 10 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page A separate TGL2 can be added in the unlikey event that another ground bar is required. Note: See page 11-4, AL Series Lighting Panelboards as replacements for A load centers BuyLog Catalog

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Residential. Section 1.

Residential. Section 1. Load enters Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in ircuit reakers...1-5

More information

Section 3: Molded Case Circuit Breakers

Section 3: Molded Case Circuit Breakers Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Load Centers and Circuit Breakers. Section 1.

Load Centers and Circuit Breakers. Section 1. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Section 1. Load Centers and Circuit Breakers.

Section 1. Load Centers and Circuit Breakers. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits... 1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Load Centers and Circuit Breakers

Load Centers and Circuit Breakers Midwest lectric Products Load enters and ircuit reakers MLM4020U TQL2140 TQL11202 TQL1115 TQL2120T Midwest Load enters pplication Information Midwest load centers lower your costs by making installation

More information

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers Molded Case Circuit Breakers Section 3 QLine Circuit Breakers Cablein Cableout (luglug) 240V Class TQD 240 Vac, Internal Common Trip # of Ampere 240 Vac Price Poles Rating Interrupting Rating Product Number

More information

Load Centers and Circuit Breakers. Section 1.

Load Centers and Circuit Breakers. Section 1. Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits...1-2 PowerMark Gold Load enters Features and enefits...1-3 PowerMark Gold and Plus Load enters Number Guides...1-4 Q-Line Plug-in

More information

Section 3. Molded Case Circuit Breakers.

Section 3. Molded Case Circuit Breakers. Molded Case Circuit Breakers Section 3 Industrial Circuit Breakers How to Order...3-2 Features...3-4 Quick Reference Guide...3-5 Q-Line Circuit Breakers Plug-In 120/240V Class...3-11 Plug-In 240V Class...3-13

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Molded Case Circuit Breakers. Section 6.  BuyLog Catalog 6-1 Molded Case Circuit Breakers Section 6 Industrial Circuit Breakers How to Order...6-2 Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 120/240V Class...6-14 Plug-In 240V Class...6-16

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

Section 6. Molded Case Circuit Breakers. BuyLog Catalog 6-1. Section Updated 03 / 2014

Section 6. Molded Case Circuit Breakers.   BuyLog Catalog 6-1. Section Updated 03 / 2014 Molded Case Circuit Breakers Section Updated 0 / 014 Section 6 Industrial Circuit Breakers How to Order...6- Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 10/40V Class...6-14

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

Full line. Full service. Full value. GE Residential Products

Full line. Full service. Full value. GE Residential Products Full line. Full service. Full value. GE Residential Products [ ONTENTS] Full line, full service, full value................................. 1 Q Line circuit breakers........................................

More information

Section 8 Stab-lok Circuit Breakers

Section 8 Stab-lok Circuit Breakers Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

Modular Metering Application Guide. Meter Mod * III Product Family

Modular Metering Application Guide. Meter Mod * III Product Family Modular Metering Application Guide Meter Mod * III Product Family Table of Contents Page No. Selection Guidelines and Nomenclature 3 UL Standard Listing and File Numbers for Meter Mod III Product Family

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Retail Reference Guide

Retail Reference Guide www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Molded Case Circuit Breakers. Section 6.  BuyLog Catalog 6-1 GuardEon Circuit Breakers Overview...6-2 Industrial Circuit Breakers How to Order...6-4 Features...6-6 Quick Reference Guide... 6-8 Q-Line Circuit Breakers Plug-In 120/240V Class...6-16 Plug-In 240V Class...

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 WireGuide Load Centers and Breakers -4 PL Series Load Centers Features

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002 Underwriters Laboratories Inc. Marking Guide Molded Case Circuit Breakers 600 Volts or Less April 2002 59 *UL has developed the Molded-Case Circuit Breaker Marking Guide to assist AHJs and installers in

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work GE Energy Industrial Solutions EV Charging Station Application Guide imagination at work EV Charging Station Introduction The GE EV Charging Station offers Level II charging capable of reducing charge

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers Q-Line Circuit Breakers Accessories 240V Class Terminals (Lugs) for Q-Line Circuit Breakers Ampere Rating Termination Type Wire Range (Cu/Al) Product Number 15-60 Lug (line only) 14-6/12-2 TQAL3A 15-60

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information Manufacturer Description Weight per unit Product Category CH2AFIT 2P A Arc Fault Shared /Indpndt Trip BRKR Eaton Corp Features Current Rating AMPERE Interrupting Rating 10 KILOAMPERE Poles 2 Terminal Type

More information

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH 06/3/4 Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Installing a Downstream Distribution Panelboard

Installing a Downstream Distribution Panelboard Job Sheet 5 Installing a Downstream Distribution Panelboard OBJECTIVE To install a downstream distribution panelboard (DDP) on the Mobile Workstation. To mechanically and electrically connect the DDP to

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H Arc-Fault and Ground-Fault s Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked

More information