Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

Size: px
Start display at page:

Download "Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator"

Transcription

1 olier room components 0870E October 2017 oiler room manifold Description The boiler room manifold is a steel multi-function device including derivations for the primary and secondary circuits, automatic air vent valve, drain tap and insulation shell. t is generally used in boiler rooms of heating and cooling systems featuring multiple regulation zones. The manifold allows for easy installation of two or three R586R distribution units, based on the version. ts modular design enables to install two manifolds in series and in turn up to six R586R distribution units, thus satisfying the requirements of large installations. n addition, the manifold includes an adjustable hydraulic separator function to easily control the flows of the primary and secondary circuits. Versions and product codes roduct code rimary side connections Secondary side connections Secondary side number of connections Technical data Operational fluid: water, glycol-based solutions (max. 50 % of glycol) Temperature range: C ax. working pressure: 6 bar Centre distance of secondary side outputs: 125 mm (same centre distance of R586R units) Weight: 7,5 kg (R586SEY02); 13 kg (R586SEY03) erformance Δt delivery return Q1max 1max Q2max Q2max R586SEY02 SO SO R586SEY03 SO SO Optional R20DY016: brass 3-piece straight fitting, 1 1/4 x 1 1/4 Derivation rimary side Q1max Secondary side (single output) Q2max ax. flow [m 3 /h] 3,0 2,0 R588SEY01: pair of wall-mount brackets ote. Use the hydraulic separator function to balance the flows. Completion codes R252Y001: interception ball valve 1 F x nut 1 1/2 F, for installation of R586R distribution unit on secondary side outputs R37KY005: pair of tail pieces 1 F x nut 1 1/2 F (without interception), for installation of R586R distribution unit on secondary side outputs ote. For the installation of R586R distribution unit on secondary side outputs you must order the R252 valves or R37K tail pieces. Completion codes to be ordered depending on the installed R586SEY02 4 R252Y001 2 R37KY005 R586SEY03 6 R252Y001 3 R37KY005 rimary side max. flow Q1max [m 3 /h] 3,0 rimary side delivery-return Δt aterials anifold body: varnished steel ir vent valve, caps, drain tap: CW617 brass nsulation: closed cell e-x foam rimary side max. power 1max [kw]

2 olier room components 0870E October 2017 oiler room manifold Components S S S S 7 4 nstallation manifolds can be installed on the special wall-mount brackets using the two 8 threaded pins on the lower side. To fit the brackets to the wall, use screw anchors suitable for the type of wall and equipment weight egend rimary side outputs R588SE S Secondary side outputs R588SE 1 anifold body 2 utomatic air vent valve 3 Drain tap 4 rass caps, 5 onnet for hydraulic separator function One may choose the inlet direction of the primary side pipes, from left or right side of the manifold, but also from the lower side by using the two lower outputs originally equipped with a 1 1/4 cap. 6 Threaded pins for bracket installation 7 nsulation 8 R252 interception valves or R37K tail pieces Operation can be used both as a basic boiler room manifold and hydraulic separator, based on the installation requirements. On the manifold lower side is an adjustment bonnet OET (components COSED - ref. 5) to mechanically activate or deactivate the hydraulic separator function. 6 mm Open the bonnet completely with a 6 mm llen wrench to put the delivery and return circuits in communication and transform it into a hydraulic separator to balance the secondary side flow, if required. ote. The primary side lower outputs have the same centre distance (240 mm) of the R146 and R146 hydraulic separators size 1 1/4. 6 mm OET OE R252 ball valves, and then R586R distribution units, can be installed on the secondary side outputs. Close the bonnet completely to interrupt the communication path between delivery and return circuits and transform back into a boiler room manifold. R586R R252 OET COSED 6 mm 2

3 olier room components 0870E October 2017 oiler room manifold The modular design enables to install two manifolds in series so that up to six R586R distribution units can be installed; this is the ideal solution for large installations with proper balancing. To install the manifolds in series, use the special R20DY016 3-piece fittings. R20DY016 Warning. The power available on the primary side (1max) will be the same given in the erformance table, even when installing multiple manifolds in series. The boiler room manifold can be installed in any position, both vertically and horizontally. Warning. For vertical or upside down installations, do not install the air vent valve; replace it with a 1/2 cap if necessary. 3

4 olier room components 0870E October 2017 oiler room manifold Example of application diagram pplication diagram for heating-only system with complete of R586RY101 for high-temperature radiator zone + R586RY102 for low-temperature radiant zone and mixing valve actuator controlled by Kbus thermoregulation. T.. Kbus T.. R586R Dimensions G H H H G H H H D C F E G H H H H H D C F E D C F E roduct code. of secondary circuit derivations C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] [mm] [mm] G H R586SEY02 H H H 2 H R586SEY

5 olier room components 0870E October 2017 oiler room manifold Dimensions of installations in series nstalled codes [mm] [mm] R586SEY02 + R586SEY02 + R586R units nstalled codes R586SEY02 + R586SEY03 + R586R units [mm] [mm] nstalled codes [mm] [mm] R586SEY03 + R586SEY03 + R586R units

6 olier room components 0870E October 2017 oiler room manifold roduct specifications R586SEY02 oiler room steel multi-function manifold with connections for primary and secondary circuits (two derivations on secondary circuit), automatic air vent valve, drain tap and insulation shell. Generally used in boiler rooms of heating and cooling systems featuring multiple regulation zones. Optional installation of two manifolds to install up to six distribution units and meet the requirements of very large systems. ncludes hydraulic separator function with mechanical activation. Operational fluids: water, glycol-based solutions (max. 50 % of glycol). Temperature range: C. ax. working pressure: 6 bar. Centre distance of secondary circuit outputs: 125 mm. R586SEY03 oiler room steel multi-function manifold with connections for primary and secondary circuits (three derivations on secondary circuit), automatic air vent valve, drain tap and insulation shell. Generally used in boiler rooms of heating and cooling systems featuring multiple regulation zones. Optional installation of two manifolds to install up to six distribution units and meet the requirements of very large systems. ncludes hydraulic separator function with mechanical activation. Operational fluids: water, glycol-based solutions (max. 50 % of glycol). Temperature range: C. ax. working pressure: 6 bar. Centre distance of secondary circuit outputs: 125 mm. dditional information For additional information please check the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.. Via per lzo, San aurizio d Opaglio (O) taly 6

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone 0687N November 017 Modular manifolds for domestic water systems with outputs connection 1/ or /4 urocone R580 - R585 R580 R585 escription iacomini has introduced the R585 (with shut-off valve) and R580

More information

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB ydraulic separator-manifold SPO 559 series RT SO 01 M 21654 01084/16 replaces dp 01084/13 unction The SPO, a device which combines the functions of hydraulic separator and distribution manifold, is used

More information

Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Boiler room components 0459EN February 2018 Manual reset safety pressure switch 0459EN February 08 Manual reset safety pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts

More information

Actuator for mixing valves 0262EN March 2016

Actuator for mixing valves 0262EN March 2016 06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe

More information

548 hydraulic separator

548 hydraulic separator hydraulic separator 120 C 120 105 C 105 120 Serie 548 120 C 105 C 105 548 imensions C B Function The ltecnic 548 hydraulic separator combines several different components, each of which performs a specific

More information

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They

More information

Metering systems 0368EN April /4 domestic water unit outputs

Metering systems 0368EN April /4 domestic water unit outputs 068EN pril 08 / domestic water unit outputs 07U98 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions

More information

FCU Floor Control Unit

FCU Floor Control Unit Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options

More information

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB Motorised temperature regulating unit for heating and air conditioning systems 67...WYP - 67...UPM series CCREDITED ISO 9 FM 65 CLEFFI 5/7 G replaces dp 5/ G Function The motorised temperature regulating

More information

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset 0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically

More information

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB otorised ball zone valves with -contact control -.. BY - series 00 0/ GB replaces 0/ GB unction The motorised zone valves permit automatically shutting off the medium in air conditioning or hydraulic and

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function Hydroixer motorized temperature mixing unit 67 series CCREDITED CLEI 09/ N ISO 900 6 ISO 900 No. 000 unction The 67 series Hydroixer provides a modulating three-point floating type non-spring return motorized

More information

Pump Stations for Heating Circuits

Pump Stations for Heating Circuits Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu

More information

599 Series Zone Valve Bodies:

599 Series Zone Valve Bodies: 599 Series Zone Bodies: Two-Way and Three-Way VE VV-1 Description Features The 599 Series two-way and three-way Zone s with a 1/10-inch (2.5 mm) stroke. Direct-coupled, universal bonnet Application Ordering

More information

599 Series Zone Valve Bodies:

599 Series Zone Valve Bodies: 599 Series Zone odies: Two-Way and Three-Way Technical Instructions VE VV- VE065R VE066R Description Features pplication Ordering a The 599 Series two-way and three-way Zone s with a /0-inch (.5 mm) stroke.

More information

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with

More information

SINGLE-PIPE AND TWIN-PIPE VALVES. Technical documentation 0185EN

SINGLE-PIPE AND TWIN-PIPE VALVES. Technical documentation 0185EN SNE-PPE AND TN-PPE VAVES Technical documentation 0185EN Single-pipe and twin-pipe valves SUARY 2 Twin-pipe valves with thermostatic option 8 Single-pipe valves with thermostatic option 13 Single-pipe and

More information

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE TECHNICAL BROCHURE aesthetic performance flexibility thermal comfort PREMIUM QUALITY MECHANICAL STRENGTH IMPROVE CHANGE LIGHTNESS savings high resistance to corrosion low and high temperature systems FULL

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA Motorized ball valves with -wire control 644-644 series SO 900 M 64 SO 900 No. 000 0/ N Replaces 0/07 N unction Zone valves are used to automatically shut-off the flow, redirect or modulate hot and chilled

More information

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG FUNCTION ICMA distribution manifolds are manufactured starting from a special profile of brass bar drawn into CW617-N. They can be divided into: Distribution manifolds with or without connection fittings

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

M1000/M3000/M4000/M8000 Series

M1000/M3000/M4000/M8000 Series il mist filter /000/000/8000 Series or measurement and instrumentation, etc. in oil content inhibited circuit. S symbol T VB. Specifications escriptions 000 000 8000 ppearance Working fluid ompressed air

More information

CT3202.0_01 EN February 2018

CT3202.0_01 EN February 2018 UNDERFLOOR HEATING / RADIATOR HEATING COMPACT BRASS MODULAR MANIFOLDS (centre distance 37 mm) CT3202.0_01 EN February 2018 o o o Super compact: e.g. 11 ways (version code 3211.06.10) in just 60 cm; Insertion

More information

MANIFOLDS & WATER TEMPERATURE CONTROL

MANIFOLDS & WATER TEMPERATURE CONTROL MANIFOLDS & WATER TEMPERATURE CONTROL Overview Water based underfloor heating (UFH) systems work by turning the entire floor into one large low temperature radiator which is heated via a network of pipes

More information

Inspection boxes and accessories

Inspection boxes and accessories 06 Inspection boxes and accessories 06 Metal inspection boxes 159 TUTTO plastic inspection boxes 163 page METAL INSPECTION BOXES 16 Sheet steel boxes and compatible manifolds In order to make box selection

More information

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8 Table of Contents Introduction 3 Application 3 Chapter 2: Operation 4 Manifold Function 4 Chapter 3: Components 5 Required Parts 5 Manifold without Actuators without Pressure Bypass Kit 5 Pump Kit (QHMPK_)

More information

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA ifferential pressure by-pass valve RIT LFFI series / N ISO FM ISO No. Replaces / N Function The differential pressure by-pass valve is used in systems with a fixed speed circulating pump supplying several

More information

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide MrPEX 1 ¼ Stainless Steel Manifold Installation Guide Design MrPEX 1 1/4 Stainless Steel Manifold is made from high quality stainless steel, and is offered in 2 through 12 loop configurations. The manifold

More information

T2 Wall Hung Radiator & UFH Manifolds

T2 Wall Hung Radiator & UFH Manifolds T Wall Hung Radiator & UFH Manifolds T Topway LS Pre-Assembled Heating Manifold A range of nickel plated extruded brass manifolds pre-assembled for immediate installation for both radiator and underfloor

More information

Manifolds series 73A and 77A. Instruction manual

Manifolds series 73A and 77A. Instruction manual KAN-therm System Manifolds series 73A and 77A Instruction manual Manifolds 73A and 77A description and principles of operation................. 18 Manifolds series 73A and 77A valves adjustment............................

More information

3 & 4-Way Rotary Valves

3 & 4-Way Rotary Valves Applications: 3-way Valve 4-way Valve The ESBE 3 and 4-Way rotary valves type F are designed for mixing or diverting applications on heating and cooling systems. The valves are capable of controlling and

More information

Preassembled manifolds with flow meter, series CPRFL

Preassembled manifolds with flow meter, series CPRFL Preassembled manifolds with flow meter, series CPRFL Main features - Available in the versions with : Head connections DN./4 F Side outlet connections /4 M Centre distance between the outlet connections

More information

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating

More information

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS PRICE LIST 07 / 2008 TABLE OF CONTENTS PE-RT (PEOC -PLUS DOWLEX ) Pipe 2 Tools 3 Bend supports & sleeves 4 Slab on grade tubing fastening components 4 Plastic pipe hangers 5 Brass Fittings (Compression)

More information

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB Motorised ball valve for central heating systems 638 series M 21654 003 LI 01196/18 G replaces dp 01196/12 G unction Motorised ball valves allows both automatic shut-off and diversion of the thermal medium

More information

Zone manifold DN 25, DN 32, DN 50. Mounting and operating instructions

Zone manifold DN 25, DN 32, DN 50. Mounting and operating instructions Zone manifold DN 25, DN 32, DN 50 Mounting and operating instructions WOMIX Sportowa 31 89-200 Szubin, Poland phone/fax +48 52 382 44 50, +48 52 382 44 51 www.womix.com.pl e-mail: export@womix.com.pl Central

More information

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function HydroMixer direct distribution unit for heating systems 6 series REDITED LEI ISO 900 M 6 ISO 900 No. 000 07/ N unction The 6 series HydroMixer TM provides high temperature flow direct to secondary heating

More information

Technical documentation SINGLE PIPE AND TWIN PIPE SYSTEM VALVES 0185EN

Technical documentation SINGLE PIPE AND TWIN PIPE SYSTEM VALVES 0185EN Technical documentation SNE PPE AND TN PPE SYSTE VAVES 0185EN ONTENTS 1 TN PPE VAVES TH THEROSTAT OPTON 6 SNE PPE VAVES TH THEROSTAT OPTON 15 SNE PPE / TN PPE VAVES TH THEROSTAT OPTON, R304T SERES 18 ANUA

More information

4 relays DIN actuator

4 relays DIN actuator TECHICA SHEET relays DI actuator Description By means of internal relays, this device executes the controls received from the central unit or from the probe. It is needed to control loads such as - -coils,

More information

IPH Series Double IP Pump

IPH Series Double IP Pump P SRS U P PUP P Series ouble P Pump 3.6 to 125.9cm 3 /rev 3Pa ll the types in this new design (11) series are installation compatible with the previous design (1). ote, however, that there is no longer

More information

Engineered Water Solutions Installation and Commissioning Instructions FCU Floor Control Unit

Engineered Water Solutions Installation and Commissioning Instructions FCU Floor Control Unit Engineered Water Solutions Installation and Commissioning Instructions FCU Floor Control Unit Robust pre-assembled M3V control group constructed from PP composite with four swivel joints for connection

More information

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG FUNCTION The pre-assembled ICMA collector kits have the function of optimizing the distribution of heat transfer fluid to floor heating systems in order to improve the control of the thermal emission in

More information

Wirsbo Radiant Heating System

Wirsbo Radiant Heating System January 1, 2009 PAGE 413-1 Wirsbo Radiant Heating System A1180313 WIRSBO hepex Barrier Tube Cross Linked Polyethylene Heat Transfer tubing with EVOH Oxygen Diffusion Barrier 413-0150 5/16" Nominal hepex:

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

MrPEX 1 ½ " Brass Manifold Installation Guide

MrPEX 1 ½  Brass Manifold Installation Guide MrPEX 1 ½ " Brass Manifold Installation Guide Design MrPEX 1 ½" Brass Manifold is made from high quality alloy extruded and chrome plated after machining, and is offered in 2 through 12 loop configurations.

More information

Composite PEX-AL-PEX Tubing

Composite PEX-AL-PEX Tubing 04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected

More information

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG FUNCTION The pre-assembled ICMA collector kits have the function of optimizing the distribution of heat transfer fluid to floor heating systems in order to improve the control of the thermal emission in

More information

D I V I S I O N O F M A R S H B E L L O F R A M

D I V I S I O N O F M A R S H B E L L O F R A M PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally

More information

Installation and Operation Instructions K38 HeatBloC - DN 32

Installation and Operation Instructions K38 HeatBloC - DN 32 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K38 HeatBloC - DN 32

More information

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 82 IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 83 Adjustment knob (sets supply temperature) Mixing Valve 1 Male BSP Threads Mixing Point Supply Inlet from Boiler Temperature Gauge (indicates

More information

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC ML-136043 208/240 V. 8.5kW ML-136045 480 V. 8.5kW 3-PAN PRO ML-136037 208/240 V. 9.25kW ML-136044 480 V. 9.25kW ML-152030 3-PAN LWE 5-PAN BASIC

More information

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide MrPEX 1 ¼ Stainless Steel Manifold Installation Guide Design MrPEX 1 ¼ Stainless Steel Manifold is made from high quality stainless steel, and is offered in 2 through 12 loop configurations. The manifold

More information

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing

More information

MSC-125 and MSC-160 Manifolds for Steam Distribution and Condensate Collection.

MSC-125 and MSC-160 Manifolds for Steam Distribution and Condensate Collection. Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series 95-0055-UK-Rev1.qxd 4-09-2007 10:31 Pagina 1 Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series Main features DOMORADIANT, is a preassembled

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

Product Information. Brass Manifolds. Version A

Product Information. Brass Manifolds. Version A Product Information Brass Manifolds Version A Introduction Infloor offers a complete line of brass manifolds for radiant heating applications. This guide explains the how the manifolds work, the setup

More information

Mild Steel Dosing Pots

Mild Steel Dosing Pots Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

40 geothermal ground loop manifolds

40 geothermal ground loop manifolds 40 geothermal ground loop manifolds GeoCal (key features listed left) This is the first thermoplastic, fully modular manifold system designed specifically for installations using ground source heat pumps.

More information

VIESMANN VITOTRANS 100 Plate heat exchanger

VIESMANN VITOTRANS 100 Plate heat exchanger VIESMANN VITOTRANS 100 Plate heat exchanger Datasheet Part numbers and prices: see pricelist VITOTRANS 100 Type PWT For transfer stations from heat supply networks, for system separation in heating systems

More information

Product range Solex Technical data and dimensioning. 5 Years

Product range Solex Technical data and dimensioning. 5 Years Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system

More information

10 mm solenoid valves on manifold with multiconnection D-SUB

10 mm solenoid valves on manifold with multiconnection D-SUB 0 mm solenoid valves on manifold with multiconnection D-SUB Air inlet from both sides Exits with ø4 push-in fittings ø4 Panel mounting possible with two M3 screws on the top side 3/2 solenoid valves Electrical

More information

K35 HeatBloC with 3-temperature mixing valve

K35 HeatBloC with 3-temperature mixing valve PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K35 HeatBloC with 3-temperature

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES 19 CONTENTS ROTARY MOTORIZED VALVES INTRODUCTION AND SELECTION GUIDES Series VRG130 DN 15 50, Kvs 0.4 40, PN10 33 34 35 Series VRG140 DN 15 50, Kvs.5 40, PN10 CHANGE-OVER/DIVERTING

More information

Section - B. Air vents

Section - B. Air vents Section - Air vents AIR VENTS EXAMPLE OF APPLICATION 2 1 2 4 5 2 3 3 4 6 1 Automatic air vent valves. 2 Manual air vent valves. 3 Air vent valves with adjustable discharge nozzle. 4 Air vents with float..

More information

51 minim and duco magnetic filters for system treatment

51 minim and duco magnetic filters for system treatment Magnetic filters for heating systems 51 minim and duco magnetic filters for flush out or drain! see fluid condition so you know when to order a system clean upper chamber position to demagnetise & flush

More information

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics ir Service Units Filter pressure regulator + Lubricator - Size Series 00 Construction and working characteristics - Zinc alloy body or reinforced technopolymer body with threaded brass insert connections.

More information

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h)  1/ 1/  8. HYDRAULIC SEPARATOR CT0617.0_03 EN March 2016 o o o Threaded versions equipped with flat seat F union connections, therefore, easy installation and/or maintenance; Self-cleaning: Dirt separator equipped

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

Product and installation manual. Underfloor Heating Composite Manifold

Product and installation manual. Underfloor Heating Composite Manifold Product and installation manual Composite Manifold Contents Introduction 2 Manifold Overview 3 Manifold Design 3 Manifold Dimensions 3 Manifold Installation 4-9 Pack Requirements 4 Required Tools 4 General

More information

15100 VALVES. E. Section Building Automation and Control System Guidelines

15100 VALVES. E. Section Building Automation and Control System Guidelines 15100 VALVES PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 15050 Basic Material and Methods B. Section 15545 Chilled Water System C. Section 15550 Heat Generation D. Section 15790 Coils E. Section 15955

More information

Z2 050 Q -J +CQB 24 -SR -L

Z2 050 Q -J +CQB 24 -SR -L ZoneTight Zone Valve () (½ to ¾ ) Nomenclature Z2 050 Q -J +CQB 24 -SR -L Valve Type Z2 = 2-way Z3 = 3-way ZoneTight Chrome Plated Brass Ball and Brass Stem Valve Size 050 = ½ 075 = ¾ Quick Connect E =

More information

SINGLE-PIPE AND TWIN-PIPE VALVES. Technical documentation 0185EN

SINGLE-PIPE AND TWIN-PIPE VALVES. Technical documentation 0185EN SNE-PPE AND TN-PPE VAVES Technical documentation 0185EN Single-pipe and twin-pipe valves SUARY 3 Twin-pipe valves with thermostatic option Single-pipe valves with thermostatic option 17 Single-pipe and

More information

Supastor SS Direct unvented cylinders

Supastor SS Direct unvented cylinders Supasr SS unvented cylinders unvented cylinders for potable water installations luid low Sequence Mains Water Isolation Valve (Not Supplied) 3 bar Pressure Reducing Valve Safety roup ( Expansion Relief

More information

MANUAL VALVES LOCKSHIELD

MANUAL VALVES LOCKSHIELD 01501-G MNUL VLVS Series 163R,164R,1163R,1164R LOKSHIL Series 193R,194R,1193R,1194R Technology by nature MIN HRTRISTIS Valves and lockshield with soft seal (O-ring) on the plug Lockshields easily adjustable

More information

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS www.itap.it CREATION AND DIFFUSION OF THE STAINLESS STEEL

More information

ROTARY MOTORIZED VALVES

ROTARY MOTORIZED VALVES ROTRY MOTORIZED VLVES ESE ROTRY VLVES regulate the heating comfort of millions of households. When we decided to develop the next generation of valves and actuators, we started by asking installation engineers,

More information

VICTRIX PRO Wall-hung modular condensing boiler for heating only

VICTRIX PRO Wall-hung modular condensing boiler for heating only PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible

More information

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function Direct supply unit for heating systems 65 series ACCREDITED ISO 9 FM 65 CALEFFI 7/7 GB replaces dp 7/5 GB Function The direct supply unit performs the function of supplying the heating system circuits

More information

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d April 15, 2011 Deluge Trim 227a Order Deluge Valve Separately This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2

More information

Zone manifold DN 25, DN 32, DN 50. Mounting and Operating Instructionsi

Zone manifold DN 25, DN 32, DN 50. Mounting and Operating Instructionsi Zone manifold DN 25, DN 32, DN 50 Mounting and Operating Instructionsi WOMIX Ul. Elizy Orzeszkowej 11 89-200 Szubin tel./fax +48 52 382 44 50 fax +48 52 382 44 51 www.womix.com.pl e-mail: biuro@womix.com.pl

More information

T2 Wall Hung Radiator & UFH Manifolds

T2 Wall Hung Radiator & UFH Manifolds T Wall Hung Radiator & UFH Manifolds T Topway LS Pre-Assembled Heating Manifold A range of nickel plated extruded brass manifolds pre-assembled for immediate installation for both radiator and underfloor

More information

LEVER ACTION BALLVALVES

LEVER ACTION BALLVALVES Pipeline Products LEVER ACTION BALLVALVES ISOLATING, NON-RETURN & PRESSURE REDUCING VALVES GATEVALVES, STOPCOCKS & HOSE UNION BIBCOCKS SAFETY VALVES AND MANIFOLDS FLEXIBLE HOSES, WASHING MACHINE VALVES

More information

Installation and Operation Instructions HeatBloC K31 - DN 25

Installation and Operation Instructions HeatBloC K31 - DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions HeatBloC K31 - DN 25 2015/03

More information

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3 SELETION Terminal Unit Zone Valve 1 Select your valve body Female Thread Solder ouble Union 2 Select your cartridge type hoice of V Hot and hilled Water 50% Glycol Low Pressure Steam Pressure alanced Male

More information

GTFLOW MANIFOLD FEATURES: BENEFITS:

GTFLOW MANIFOLD FEATURES: BENEFITS: GTFLOW MANIFOLD AND ACCESSORIES GTFlow is our line of manifolds which includes all accessories needed for a complete radiant floor system. GTFlow is made with high quality brass which comes to you preassembled

More information

Installation Components AirCare Air Preparation Systems

Installation Components AirCare Air Preparation Systems Care Preparation Systems Modular Line Filters 602104 602106 602108 * Transparent 602109 nylon liquid level indicator -18 lens. to 79 C Body Bowl Material icle Zinc Aluminum Zinc* Aluminum* Sintered Polypropylene

More information

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB. Pre-assembled distribution manifold for radiant panel systems 668...S series ACCREDITED ISO 900 FM 65 ISO 900 No. 000 0/ GB Replaces 0/07 GB Function The distribution manifold for radiant panel systems

More information

LK Manifold RF. Design. Requirements. Documentation

LK Manifold RF. Design. Requirements. Documentation LK Manifold RF Design LK Manifold RF is made of stainless steel, the variants having 2 to 12 floor heating circuits. The manifold is delivered pre-mounted in brackets. The manifold has thermometers on

More information