Metering systems 0368EN April /4 domestic water unit outputs

Size: px
Start display at page:

Download "Metering systems 0368EN April /4 domestic water unit outputs"

Transcription

1 068EN pril 08 / domestic water unit outputs 07U98 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions and flow Pulse output with M-us presetting ( pulse = 0 liters) pacer for water meter for installation on site rackets for fitting in user modules rass shut-off valves with full port, chrome-plated ball, PTFE seals Check valve with POM resin body and inner parts, stainless steel spring CE marking (MID compliance) Water meter error quality diagram Y00 Y0 Description Domestic water unit outputs are used to meter domestic water consumptions. They include a pair of shut-off valves, a single-jet water meter (GEY90-9) and a spacer to replace the water meter. The water meter is equipped with a totalizer to read consumptions; a pulse output enables smart metering via M-us. The check valve integrated in the shut-off valve with a green handle provides highly reliable readings. The handles of the other shut-off valves are blue or red respectively for domestic cold or hot water outputs. Error % Q Q Q Q GEY90, GEY9 (/ ) Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Horizontal, 0,0 0,00, Vertical, 0,06 0,00, Versions and product codes Codice Tipo di acqua sanitaria ttacchi Interasse di montaggio [mm] Q / Q =,6 Q / Q = 80 (hozrizontal installation) Q / Q = 0 (vertical installation) Y00 fredda /" 0 Y0 calda /" 0 Operation Technical data Max. working temperature: 0 C for domestic cold water meter 90 C for domestic hot water meter Max. working pressure: 6 bar (0 bar with plastic spacer) hut-off valve Losses of pressure Check valve,0, Domestic water meter p [bar] oiler room or aqueduct User module (domestic water) 0, 0,0 0,0,0 Q [m /h] 0,0 Product code Connections Kv Y00 Y0 /",

2 068EN pril 08 / domestic water unit outputs 07U98 Installation Comply with rules provided for use (installation, fitting, etc.), operation, recalibration and replacement of water meters. lso refer to assembly instructions. Data centralization Water meter data can be remoted with energy meters GE and centralization components GE-. Dimensions Product code [mm] [mm] b b Y Y tandards of reference CE marking MID (0//EU) hut-off valve Plastic spacer for water meter hut-off valve with integrated check function Domestic water meter upport unit The two shut-off valves ( - ) are connected to the spacer () and sealing is provided by special gaskets. We recommend replacing the water meter with the spacer to flush the system before installing the water meter. To install the domestic water output in the user modules, use the two support units (): metering cabinets are equipped with special guides; the plate must be installed inside the guide (); the clip (b) must be installed on top of the guide and tightened using the screw (). We recommend preinstalling the support assembly before fitting the plate into the guide so that the only operation required is tightening of the screw. Once the system has been flushed, the spacer () can be replaced with the water meter (). fter installing all parts, test the system under pressure. Product specifications Y00 Domestic cold water meter output. Connections /. Two shut-off valves with blue and green handles, chrome-plated ball, PTFE seals. Check valve with POM resin body and inner parts, stainless steel spring. Domestic cold water single-jet meter, with pulse output (REED contact), nominal flow rate, m³/h, center distance 0 mm. Plastic spacer for system flushing. rackets for cabinet installation. Output length 6 mm. Max. working temperature 0 C. Max. working pressure 6 bar. CE marking (MID compliance). Y0 Domestic hot water meter output. Connections /. Two shut-off valves with red and green handles, chrome-plated ball, PTFE seals. Check valve with POM resin body and inner parts, stainless steel spring. Domestic hot water single-jet meter, with pulse output (REED contact), nominal flow rate, m³/h, center distance 0 mm. Plastic spacer for system flushing. rackets for cabinet installation. Output length 6 mm. Max. working temperature 90 C. Max. working pressure 6 bar. CE marking (MID compliance). Follow flow directions shown on water meter. Nota. For additional information on domestic water meters GEY90-9, refer to technical sheet 07EN. dditional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini.p.. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini.p.. Via per lzo, an Maurizio d Opaglio (NO) Italy

3 070EN July 08 domestic water unit outputs 07U88 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions and flow Pulse output with M-us presetting ( pulse = 0 liters) pacer for water meter for installation on site rackets for fitting in user modules rass shut-off valves with full port, chrome-plated ball, PTFE seals Check valve with POM resin body and inner parts, stainless steel spring CE marking (MID compliance) Water meter error quality diagram Y00 Y0 Description Domestic water unit outputs are used to meter domestic water consumptions. They include a pair of shut-off valves, a single-jet water meter (GEY9-96) and a spacer to replace the water meter. The water meter is equipped with a totalizer to read consumptions; a pulse output enables smart metering via M-us. The check valve integrated in the shut-off valve with a green handle provides highly reliable readings. The handles of the other shut-off valves are blue or red respectively for domestic cold or hot water outputs. Error % Q Q Q Q GEY9, GEY96 ( ) Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Horizontal,0 0,00 0,080,0 Vertical,0 0,00 0,60,0 Versions and product codes Codice Tipo di acqua sanitaria ttacchi Interasse di montaggio [mm] Q / Q =,6 Q / Q = 80 (horizontal installation) Q / Q = 0 (vertical installation) Y00 fredda " 0 Y0 calda " 0 Operation Technical data Max. working temperature: 0 C for domestic cold water meter 90 C for domestic hot water meter Max. working pressure: 6 bar (0 bar with plastic spacer) hut-off valve Losses of pressure,0, Check valve Domestic water meter oiler room or aqueduct p [bar] User module (domestic water) 0, 0,0 0,0,0 Q [m /h] 0,0 Product code Connections Kv Y00 Y0 ",

4 070EN July 08 domestic water unit outputs 07U88 Installation Comply with rules provided for use (installation, fitting, etc.), operation, recalibration and replacement of water meters. lso refer to assembly instructions. Data centralization Water meter data can be remoted with energy meters GE and centralization components GE-. Dimensions Product code [mm] [mm] b b Y Y tandards of reference CE marking MID (0//EU) hut-off valve Plastic spacer for water meters hut-off valve with integrated check function Domestic water meter upport unit The two shut-off valves ( - ) are connected to the spacer () and sealing is provided by special gaskets. We recommend replacing the water meter with the spacer to flush the system before installing the water meter. To install the domestic water output in the user modules, use the two support units (): metering cabinets are equipped with special guides; the plate must be installed inside the guide (); the clip (b) must be installed on top of the guide and tightened using the screw (). We recommend preinstalling the support assembly before fitting the plate into the guide so that the only operation required is tightening of the screw. Once the system has been flushed, the spacer () can be replaced with the water meter (). fter installing all parts, test the system under pressure. Product specifications Y00 Domestic cold water meter output. Connections. Two shut-off valves with blue and green handles, chrome-plated ball, PTFE seals. Check valve with POM resin body and inner parts, stainless steel spring. Domestic cold water single-jet meter, with pulse output (REED contact), nominal flow rate,0 m³/h, center distance 0 mm. Plastic spacer for system flushing. rackets for cabinet installation. Output length 0 mm. Max. working temperature 0 C. Max. working pressure 6 bar. CE marking (MID compliance). Y0 Domestic hot water meter output. Connections. Two shut-off valves with red and green handles, chrome-plated ball, PTFE seals. Check valve with POM resin body and inner parts, stainless steel spring. Domestic hot water single-jet meter, with pulse output (REED contact), nominal flow rate,0 m³/h, center distance 0 mm. Plastic spacer for system flushing. rackets for cabinet installation. Output length 0 mm. Max. working temperature 90 C. Max. working pressure 6 bar. CE marking (MID compliance). Follow flow directions shown on water meter. Note. For additional information on domestic water meters GEY9-96, refer to technical sheet 07EN. dditional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini.p.. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini.p.. Via per lzo, an Maurizio d Opaglio (NO) Italy

5 06EN pril 08 ervice water unit outputs 07U788 Main characteristics Module GEY0 with M-us outlet (splittable from water meter) M-us module battery life: indefinite with M-bus feed; one year without M-us feed (activated after first reading of water meter) Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions and flow pacer for water meter for installation on site rackets for fitting in user modules rass shut-off valves with full port, chrome-plated ball, PTFE seals Check valve with POM resin body and inner parts, stainless steel spring CE marking (MID compliance) Error quality diagram Description Unit output Y008 is enhanced for use as third output in service water metering. It includes a pair of shut-off valves, a single-jet water meter (GEY) and a spacer to replace the water meter. The check valve integrated in the shut-off valve with a green handle provides highly reliable readings. The M-us module (GEY0) is included: the water meter output cables are already set with the M-us signal, as opposed to the other domestic water meters that feature a pulse output. Item Y008 can be used also as standard device with domestic cold water. Versions and product codes Product code Type of domestic water Connections Y008 Installation center distance [mm] Y008 fredda - di servizio /" 0 Error % Q Q Q Q GEY (/ ) Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Horizontal, 0,0 0,00, Vertical, 0,0 0,00, Q / Q =,6 Q / Q = 00 (horizontal installation) Q / Q = 0 (vertical installation) Techincal data Max. working temperature: 0 C Max. working pressure: 6 bar (0 bar with plastic spacer) Operation Losses of pressure,0, hut-off valve p [bar] 0, Check valve Domestic cold water meter oiler room or aqueduct User module (domestic water) 0,0 0,0,0 Q [m /h] 0,0 Product code Connections Kv Y008 /",0

6 06EN pril 08 ervice water unit outputs 07U788 Installation Comply with rules provided for use (installation, fitting, etc.), operation, recalibration and replacement of water meters. lso refer to assembly instructions 6 Data centralization Water meter data can be remoted with energy meters GE and centralization components GE-. Dimensions b Product code [mm] [mm] Y b tandards of reference CE marking MID (0//EU) hut-off valve with integrated check function Plastic spacer for water meters hut-off valve Domestic water meter upport unit 6 M-us module GEY0 The two shut-off valves ( - ) are connected to the spacer () and sealing is provided by special gaskets. We recommend replacing the water meter with the spacer to flush the system before installing the water meter. Item Y008 includes three supports to fit the user modules: the user modules are equipped with special guides; the plate must be installed inside the guide (); the clip (b) must be installed on top of the guide and tightened using the screw (). We recommend preinstalling the support assembly before fitting the plate into the guide so that the only operation required is tightening of the screw. Once the system has been flushed, the spacer () can be replaced with the water meter (). fter installing all parts, test the system under pressure. Product specifications Y008 Domestic cold water unit output for service water. Connections /. Two shut-off valves with blue and green handles, chrome-plated ball, PTFE seals. Check valve with POM resin body and inner parts, stainless steel spring. Domestic cold water single-jet meter, with M-us module, nominal flow, m³/h, center distance 0 mm. Plastic spacer for system flushing. rackets for cabinet installation. Output length 6 mm. Max. working temperature 0 C. Max. working pressure 6 bar. CE marking (MID compliance). Note. For additional information on domestic water meters GEY, refer to technical sheet 07EN. Follow flow directions shown on water meter. dditional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini.p.. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini.p.. Via per lzo, an Maurizio d Opaglio (NO) Italy

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone 0687N November 017 Modular manifolds for domestic water systems with outputs connection 1/ or /4 urocone R580 - R585 R580 R585 escription iacomini has introduced the R585 (with shut-off valve) and R580

More information

Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Boiler room components 0459EN February 2018 Manual reset safety pressure switch 0459EN February 08 Manual reset safety pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts

More information

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They

More information

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset 0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically

More information

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator olier room components 0870E October 2017 oiler room manifold Description The boiler room manifold is a steel multi-function device including derivations for the primary and secondary circuits, automatic

More information

Actuator for mixing valves 0262EN March 2016

Actuator for mixing valves 0262EN March 2016 06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

FIVC. Static Balancing Valve. Technical data. Dimensions

FIVC. Static Balancing Valve. Technical data. Dimensions FIVC Static Balancing Valve Grey Cast Iron PN 16 Technical data Main features and materials High tightness (leakproofness class - A according to EN - 12266-1) Compact settlement Environment-friendly Tests

More information

DN 1/4" to 2" Threaded Female BSP -10 C C Max Pressure : Bars Specifications : Reduced bore High pressure Hydraulic type

DN 1/4 to 2 Threaded Female BSP -10 C C Max Pressure : Bars Specifications : Reduced bore High pressure Hydraulic type Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2" Threaded Female BSP -10 C + 100 C Max Pressure : 315 500 Bars Specifications : Reduced bore High pressure Hydraulic type Materials : Galvanized

More information

Electronic Water Meters

Electronic Water Meters 5 341 Electronic Water Meters WFC... WFH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values

More information

Installation Locations and Accessories for Temperature Probes

Installation Locations and Accessories for Temperature Probes Page 1/8 Installation ocations and Accessories for Temperature Probes Ball valves T-pieces Adapter screw fittings Installation accessories The correct selection of installation locations for acquiring

More information

Peter Meyer Ball valves Cryogenic

Peter Meyer Ball valves Cryogenic Peter Meyer Ball valves Cryogenic Features Swiss manufacturer One-piece body design Laser welded, whitout body seal Chambered seats Cryogenic extension Cavity pressure relief system Replaceable packing

More information

RMG Meßtechnik GmbH. Publication No E

RMG Meßtechnik GmbH. Publication No E Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

Installation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500

Installation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 LXLC(R)-50-200 LXLC(R)-250-300 APPLICATION Measuring the volume of cold (hot) water passing through the pipeline FEATURES Magnet-drive,

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

PF Coil 2-6 Supply. Main technical aspects. P. Valente

PF Coil 2-6 Supply. Main technical aspects. P. Valente PF Coil 2-6 Supply Main technical aspects P. Valente PF Coils EI Information Meeting Cadarache, 19 February 2013 This presentation is intended for reference purposes only and is not a legally binding document

More information

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering

More information

M 140 Multi-jet Water Meter Calibrated metering insert for cutting first-time installation, maintenance and refurbishing costs

M 140 Multi-jet Water Meter Calibrated metering insert for cutting first-time installation, maintenance and refurbishing costs M 140 Multi-jet Water Meter Calibrated metering insert for cutting first-time installation, maintenance and refurbishing costs Type. Nominal flow rate Q n 1.5. Dry-dial meter with glass-clear display face.

More information

m-csg Ultra-compact Clean Steam Generation System

m-csg Ultra-compact Clean Steam Generation System Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment. Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS (Rev. 2.0_10-2010) DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS TRVK 2003 to 5003 TRSK 2005 to 5005 INTRODUCTION These instructions are for the maintenance staff in case of repair

More information

Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications

More information

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING! BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ DOSING PUMPS SERIE ACL - AXL - DPZ STORAGE TANKS SERIE SL WATER METER SERIE CD - CW INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization

More information

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be > Domestic Water Meter Type EV, optionally with pulse output Type EV-A prepared for remote acquistion. Nominal flow rate Q n 1.5...

More information

Assembly and operating Instructions. Bypass Flow Meter DST

Assembly and operating Instructions. Bypass Flow Meter DST Assembly and operating Instructions Bypass Flow Meter 2 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions and exemption from liability... 3 2.3. Intended

More information

Electronic Heat Meters

Electronic Heat Meters 5 333 WFQ2... WFM2... MEGATRON2 Electronic Heat Meters WFM2... WFQ2... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

Water and Chemical Batching. Precision Measurement for Ready-Mix and Concrete Batch Plants. Concrete Meter Overview

Water and Chemical Batching. Precision Measurement for Ready-Mix and Concrete Batch Plants. Concrete Meter Overview Water and Chemical Batching. Precision Measurement for Ready-Mix and Concrete Batch Plants. Concrete Meter Overview Every drop counts. Measure and precisely control the amount of water and chemical additives

More information

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate

More information

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves - Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting

More information

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TA-6-way valve. Standard control valves 6-way valve for change-over systems TA-6-way valve Standard control valves 6-way valve for change-over systems IMI TA / Control valves and Actuators / TA-6-way valve TA-6-way valve The 6-way valve solution enables various control set-ups

More information

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

BALL VALVE SERIES Pneumatic actuator - El-O-Matic B C D E BALL VALVE - 350 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F DIMENSIONS: (mm) Ø DN B PD PE PD C D E F Kg PE C

More information

Oil Meter HZ 3 and HZ 3 RR Mounting Instructions

Oil Meter HZ 3 and HZ 3 RR Mounting Instructions Oil Meter HZ 3 and HZ 3 RR Mounting Instructions Scope of supply 1. HZ 3 oil meter or HZ 3 RR oil meter 2. Lip sealing ring (2 off) 3. Clamps (3 off) 4. Mounting plate 5. Mounting instructions Safety advice

More information

Electronic Water Meters in measuring cell design

Electronic Water Meters in measuring cell design 5 343 SIEMECA Electronic Water Meters in measuring cell design WMC... WMH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

BALL VALVE HIT SERIES Pneumatic actuator - El-O-Matic

BALL VALVE HIT SERIES Pneumatic actuator - El-O-Matic B C D E BALL VALVE - 516 HIT SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F A L DIMENSIONS: (mm) DN L A B PD PD C D E F Kg

More information

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control

More information

Compact Static Heat Meter of High-Tech Composite

Compact Static Heat Meter of High-Tech Composite Compact Static Heat Meter of High-Tech Composite Application The Superstatic 789 is a lightweight and robust compact heat meter consisting of a high-tech composite flow meter, a detachable integrator with

More information

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

BALL VALVE SERIES Pneumatic actuator - El-O-Matic C D E BALL VALVE - 1370 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F L DIMENSIONS: (mm) Ø L C PD PE PD D E F Kg PE D E

More information

Electric Flanged PN16 Cast Iron Ball Valve

Electric Flanged PN16 Cast Iron Ball Valve Electric actuator direct mounted Type: E4813BS Electric actuator fitted via kit Main J3 Smart electric actuator features: LED light for continual visual actuator status feedback. Fully weatherproof smart

More information

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic C D E FIGURE: PD: pneumatic actuator, double acting PE: pneumatic actuator, spring return PEO: pneumatic actuator, spring return, normally open BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

More information

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be S 00 Single-jet Water Meter Unobtrusively upmarket just what it should be > Domestic Water Meter Type EV, optionally with pulse output Type EV-A prepared for remote acquistion. Nominal flow rate Q n.5...

More information

V-7 Valves. Installation and Parts INSTALLATION: M400-10: V2: 03/17. An IDEX Energy & Fuels Business. V7 Valves IOM and Parts

V-7 Valves. Installation and Parts INSTALLATION: M400-10: V2: 03/17. An IDEX Energy & Fuels Business. V7 Valves IOM and Parts V-7 Valves Installation and Parts L I Q UID C O N T R O L S An IDEX Energy & Fuels Business V7 Valves IOM and Parts INSTALLATION: M400-10: V2: 03/17 WWW.LCMETER.COM 1 TABLE OF CONTENTS Description...Page

More information

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT Installation erada 1200 Series CS Faucet S53-325 Battery-Operated Capacitive Sensing Gooseneck Faucet Centershank with 4-inch Trim Plate (Optional: 8-inch or No Trim Plate) Table of Contents Supplies Required..................

More information

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS PUSH FITTINGS INSTALLATION AND COMPONENTS SUMMARY 1. USE 1. TECHNICAL DATA 2. INSTALLATION WITH SYNTHETIC PIPES 3. INSTALLATION WITH COPPER PIPES 5. COMPONENTS 9. GUARANTEE June 2010 0135EN ISO 9001 0006/6

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Supercal 539. Compact thermal energy meter

Supercal 539. Compact thermal energy meter Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling

More information

BUE: 3-way flanged valve, PN 16/10 (el.)

BUE: 3-way flanged valve, PN 16/10 (el.) Product data sheet 56.116 BUE: 3-way flanged valve, PN 16/10 (el.) How energy efficiency is improved Efficient use in continuous control systems Features Continuous control of cold and hot water in closed

More information

Volumeter. RMG Meßtechnik GmbH. Publication No E

Volumeter. RMG Meßtechnik GmbH. Publication No E Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

GIACOGREEN Pipes and Fittings in Polypropylene Random

GIACOGREEN Pipes and Fittings in Polypropylene Random GIACOGREEN Pipes and Fittings in Polypropylene Random GIACOMINI s.p.a. 28017 S.Maurizio d Opaglio (Novara) Tel. 0322-923111 Fax 0322-96256 Telex 200035 www.giacomini.com dal 1951 January 2000 GIACOMINI,

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

BUTTERFLY VALVE - 18/28 SERIES Pneumatic actuator - El-O-Matic

BUTTERFLY VALVE - 18/28 SERIES Pneumatic actuator - El-O-Matic B C D FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return BUTTERFLY VALVE - 18/28 SERIES Pneumatic actuator - El-O-Matic G F L The pneumatic actuator is calculated for 6

More information

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected

More information

H. HERMANN EHLERS GMBH

H. HERMANN EHLERS GMBH H. HERMANN EHLERS GMBH Fördern - Messen - Regeln - Dosieren - Verdichten Ingenieurbüro - Werksvertretungen Positive displacement meters series - - An der Autobahn 45 28876 Oyten Tel. 04207/91 21-0 Fax

More information

PORTIONATOR M100. Portionator M100 Meter/Dispense System

PORTIONATOR M100. Portionator M100 Meter/Dispense System PORTIONATOR M100 Portionator M100 Meter/Dispense System METER AND DISPENSE ANY TWO COMPONENT EPOXY, URETHANE, OR SILICONE PULL THE HANDLE AND DISPENSE ONLY AS MUCH AS YOU NEED, EXACTLY WITH PRECISE MIX

More information

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate

More information

DI PUMP PARTS PRICE LIST

DI PUMP PARTS PRICE LIST ITEM 1 2 2A PUMP 5040 Pump Body, 1-1/2" NPT Mech. Seal 1 40058 1 5040 Pump Body, 1-1/2" NPT, Packing 1 40057 1 5040 Pump Body, 1-1/2" 150# Flg., Mech. Seal 1 40787 1 5040 Pump Body, 1-1/2" 150# Flg., Packing

More information

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347-7, cast body with welding ends Type 3347-7, bar stock body with threaded connections Mounting and Operating Instructions EB 8097 EN Edition

More information

Edition 2 May Air Drill. 551 Series. Parts Information. Save These Instructions

Edition 2 May Air Drill. 551 Series. Parts Information. Save These Instructions 16606097 Edition 2 May 2014 Air Drill 551 Series Parts Information Save These Instructions 551 Series Air Drill Diagram 16 110 111 113 114 112 Enlarged detail of Rubber-faced Throttle Valve 17 82 19 18

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES AQT-56 POWERFLO SERIES SERVICE MANUAL Table of Contents Products Checking List 3 General Residential Installation Check List 4 AQT-56ST Softener Timer Control Valve Start-up Procedures 5 AQT-56FT Filter

More information

Telescopic slides 603

Telescopic slides 603 603 Technical information for telescopic slides Construction: consist of two or more ball-bearing supported guide rails mounted one inside another that can be pulled out like a telescope. The load rating

More information

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4E. ( 3 4x18) 3/4E DESCRIPTION 63/2E Six-way ballvalve with ¾ M eurocone ends for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, the control of radiant ceilings, fan coils

More information

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems T-6-way valve NPT threads Standard control valves 6-way valve for change-over systems IMI T / Control valves / T-6-way valve NPT threads T-6-way valve NPT threads The 6-way valve solution enables various

More information

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump

More information

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB otorised ball zone valves with -contact control -.. BY - series 00 0/ GB replaces 0/ GB unction The motorised zone valves permit automatically shutting off the medium in air conditioning or hydraulic and

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

SBMD 75 - BMD 200 BMD BMD 600

SBMD 75 - BMD 200 BMD BMD 600 Positive displacement meters series - - w w w. i s o i l m e t e r. c o m with VEGA II The solutions that count with mechanical counter with ENCODER Positive displacement meters series - - ISOIL PD meter

More information

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50)

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50) VGx-xx-xx Externally Threaded Control all Valves PN25 ( TO DN50) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to VDI2035

More information

BUD: 3-way flanged valve, PN 6 (pn.)

BUD: 3-way flanged valve, PN 6 (pn.) Product data sheet 76.111 BUD: 3-way flanged valve, PN 6 (pn.) How energy efficiency is improved Efficient use in continuous control systems Features Continuous control of cold and hot water in closed

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet V503 Kombi--plus Manual double regulating balancing valve Product specification sheet Application The V503 Kombi--plus is a static, variable orifice doubleregulating balancing valve for the return with

More information

CPLab / CP Factory. Application module magazine. Data sheets

CPLab / CP Factory. Application module magazine. Data sheets CPLab / CP Factory Application module magazine Data sheets Data sheet: Push-in fitting QSM-M5-4 #153304 Size Mini Nominal size 2.2 mm Type of seal on screw-in stud Sealing ring Container size 10 Design

More information

VPI45..Q with pressure test points. Combi valves, PN 25

VPI45..Q with pressure test points. Combi valves, PN 25 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

BALL VALVE SERIES Pneumatic actuator - El-O-Matic B C D E BALL VALVE - 1515 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F A L DIMENSIONS: (mm) DN L A B PD PE PD C D E F Kg

More information

BM 048 BMW F 650 GS Dakar

BM 048 BMW F 650 GS Dakar Öhlins shock absorber 46 HRCS Your Öhlins shock absorber type 46 HRCS features the following adjusters: Compression damping adjuster Adjustments are made on top of the reservoir. Rebound damping adjuster

More information

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance AutoFaucet with urround ensor Technology Installation & Maintenance Instalaion y Mantenimiento Installation Et Maintenance on www.technicalconcepts.com or call 800-551-5155 Looks Clean - Is Clean. AutoFaucet

More information

MOUNTING SYSTEMS SPECIFICATIONS

MOUNTING SYSTEMS SPECIFICATIONS MOUNTING SYSTEMS SPECIFICATIONS GENERAL Mounting Systems shall allow Track Systems to be fastened to or from various surfaces in a wide range of safe and approved methods. Mounting Systems shall have a

More information

SU 201 Suzuki V-storm 1000

SU 201 Suzuki V-storm 1000 Öhlins shock absorber 46 PRCS Your Öhlins shock absorber type 46 PRCS features the following adjusters: Compression damping adjuster (C) Adjustments are made on top of the reservoir. Rebound damping adjuster

More information

Vacuum Breakers. Brass Construction 3/4 MHT Outlet

Vacuum Breakers. Brass Construction 3/4 MHT Outlet Vacuum Breakers Brass Construction 3/4 MHT Outlet MASTER ITEM # DESCRIPTION INNER CAR- TON QTY CARTON QTY HPVVBRB 3/4 FHT x 3/4 MHT Rough Brass 20 200 HPVVBCP 3/4 FHT x 3/4 MHT Chrome Plated 20 200 1 Body

More information

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE OPERATOR MANUAL 635360-X INCLUDING: OPERATION, INTALLATION & MAINTENANCE ELECTRONIC PREET DIGITAL METER FOR UE WITH LUBRICATION FLUID RELEAED: 10-7-04 REVIED: 6-11-10 (REV. 03) READ THI MANUAL CAREFULLY

More information

Edition 2 July Air Impact Wrench. 2934P2 and 2940P2. Parts Information. Save These Instructions

Edition 2 July Air Impact Wrench. 2934P2 and 2940P2. Parts Information. Save These Instructions 04584470 Edition 2 July 2008 Air Impact Wrench 2934P2 and 2940P2 Parts Information Save These Instructions 2934P2 and 2940P2 Air Impact Wrench Exploded Diagram 60 59 16 18 10 15 9 8 7 6 5 4 14 1 13 3 2

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INDEX INDEX... 2 REVISION INDEX... 2 INTRODUCTION... 3 GENERAL WARNINGS... 3 DESCRIPTION... 4 MAIN COMPONENTS... 5 MECHANICAL INSTALLATION... 6 INSTALLATION

More information

C1448, C1848, C2148 Service Parts

C1448, C1848, C2148 Service Parts C8, C88, C8 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C8, C88, C8 ice machines. To avoid costly and time consuming errors, double check

More information

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

BALL VALVE SERIES Pneumatic actuator - El-O-Matic B C D E BALL VALVE - 730 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F A L DIMENSIONS: (mm) Ø L A B PD PE PD C D E F Kg

More information

Type 441 XXL 442 XXL. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Type 441 XXL 442 XXL. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E Type 441 442 Flanged Safety Relief Valves spring loaded Metric Units Facts The-Safety-Valve.com LWN 462.07-E Conventional design 40 Bolted Cap H1 18 Adjusting screw 19 Lock nut 69 Needle bearing 16 Upper

More information

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder

More information

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Installation Instruction Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Table of contents Page 1 Function of Turbotron 1 2 Safety instructions 2 3 Important notes and requirements

More information

SECTION VALVES. A. Extent of Valve Work is indicated on the Drawings and by the Requirements of this Section.

SECTION VALVES. A. Extent of Valve Work is indicated on the Drawings and by the Requirements of this Section. PART 1 GENERAL 1.01 DESCRIPTION OF WORK SECTION 22412 VALVES A. Extent of Valve Work is indicated on the Drawings and by the Requirements of this Section. B. All valves, except those are 2 in diameter

More information

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic C D E BALL VALVE - 30BA SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F DIMENSIONS: (mm) Ø DN C PD PE PD D E F Kg PE D E G

More information

Rated Current. Test Voltage

Rated Current. Test Voltage SINGLE POLE HIGH VOLTAGE CONNECTORS 10 / 20 / 30 / 40kV FEATURES Up to 40kVDC / 30A 100,000 Mating Cycles UL94 V-0 Flammability Rating Extended Temperature Range Central Attachment Low Cost Made in Germany

More information

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL TopStick Fixed installation technology LOW VOLTAGE SWITCH PANEL TopDraw plus The modular system solution Quality, Conformity Increased

More information

Residential Water Meters

Residential Water Meters EnergyMetering Residential Water Meters Multi-jet wet dial meters Multi-jet dry dial meters Positive displacement meters AMR-technology All that counts. Technology of the highest standard Quality and reliability

More information