Appendix ISO /03/05/07/08

Size: px
Start display at page:

Download "Appendix ISO /03/05/07/08"

Transcription

1 ppendix ISO /03/05/07/08

2 Fluid Recommendations Viscosity & Cleanliness Recommendation Minimum Optimum Maximum ISO Cleanliness 6.0 cst cst 2158 cst 20/18/15 (45 SUS) ( SUS) (10000 SUS) Introduction Hydraulic fluids are one of the vital components of hydraulic system. roper selection of oil assures satisfactory life and operation of system components. he purpose of this section is to provide readers with the knowledge required to select the appropriate fluids for use in systems that employ Eaton hydraulic components Viscosity and emperature Viscosity is the measure of a fluid s resistance to flow. he most important characteristics to consider when choosing a fluid to be used in a hydraulic system is viscosity. he fluid must be thin enough to flow easily but thick enough to maintain adequate lubricating film between components and to maintain proper sealing at the operating temperatures of the hydraulic system. For viscosity requirements, see table. Viscosity of any fluid is relative to temperature, as the fluid warms the viscosity decreases and vice versa. When choosing a fluid, it is important to consider the start-up and operating temperatures of the hydraulic system. high VI fluid shows relatively small change of viscosity with temperature. ubricants used for hydraulic applications may contain viscosity index improvers (VII). hey refer to these fluids as viscosity index improved or multiviscosity fluids. he viscosity of these fluids may drop down in use due to shearing ofvi improvers used in the formulations. nti-wear hydraulic oils containing polymeric thickeners, viscosity index improvers (VII) are generally used for wide band operating temperature applications hese fluids experience temporary and permanent viscosity loss during use in hydraulic system. Check the extent of viscosity loss (shear stability) to avoid hydraulic service below the recommended minimum viscosity. Oil with good shear stability is recommended for wide band temperature applications. Multi-grade engine oils, Fs, UOs, etc., also contain VIIs, and viscosity loss will be encountered during use. Cleanliness Cleanliness of the fluid in a hydraulic system is extremely important. More than 70% of all failures are caused by contamination Eaton recommends that the fluid used in its hydraulic components be maintained per ISO Cleanliness level requirements vary with the hydraulic components. he cleanliness of a hydraulic system is dictated by the cleanliness requirements of the most stringent component in the system. Cleanliness requirements for specific products are given in the table. OEM s and distributors who use Eaton hydraulic components in their hydraulic systems should provide these requirements in their designs. Contact Eaton filter representative for filtration information. Fluid Maintenance he condition of a fluid has a direct effect on the performance and reliability of the system. Maintaining proper fluid viscosity, cleanliness level, water content, and additive level is essential for excellent hydraulic system performance. Routine fluid condition monitoring is recommended. Fluid Selection remium grade anti-wear (W) petroleum based hydraulic fluids will provide the best performance with Eaton hydraulic components. ubricants that pass Eaton Vickers 35V25 high pressure vane pump test (Eaton S- 373 test procedure, SM specification D 6973) are considered good quality antiwear hydraulic fluids. utomotive crank case oils with merican etroleum Institute (I) letter designation SF, SG, SH, SJ, or higher per SE J 183 classes of oils are recommended for applications using Eaton DG valves utomotive crankcase oils generally exhibit less shear stability compared to industrial anti-wear hydraulic fluids, which can result in higher loss of viscosity during service life. Other mineral oil based lubricants commonly used in hydraulic systems are automatic transmission fluids (F) and universal tractor transmission oils (UO). Synthetic hydrocarbon base stocks, such as polyalphaolefins (O) are also used to formulate hydraulic fluids, engine oils, Fs and UOs lternate fluids are recommended when specific properties, such as fire resistance biodegradability etc., are necessary for the application. Keep in mind that alternative fluids may differ from W petroleum fluids in properties. dditional Notes When choosing a hydraulic fluid, all the components in the system must be considered. Viscosity limitations has to meet the most stringent component requirements. For any system where the fluid is non-petroleum oil, set the target one ISO code cleaner for each particle size, than that of petroleum fluids. Keep adequate fluid level in the reservoir. ake fluid level reading when the system is cold. For more details, refer to Eaton Fluid Recommendation Document # Contact your Eaton representative, if you have specific questions about the fluid requirements of Eaton hydraulic components. -2 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

3 abulation of bolt kits and seal kits Direction control single stage I Size 2 (D02) olt kit (metric) Seal kit Seal kit comments DG4V-2 DG2V-2 DG17V-2 DG21V II Size 3 (D03) olt kit (metric) Seal kit Seal kit comments Seal kit for DG4V 360 din Seal kit for DG4V 360 flying lead DG4V Seal kit for F6-DG4V3(S) Seal kit - DG4V-3M-* Seal kit - F6-DG4V- 3M-* Soft shift seal kit DG4V F F6 DG3/4V Nitrile Viton (F3) DG3V DG17V DG18V DG20V III. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DG4V C DC Direction Control wo stage I. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DG3V-5/ DG5V-5 II. Size 7 (D07) olt kit (metric) Seal kit Seal kit comments DG3V-7/ DG5V III. Size 8 (D08) olt kit (metric) Seal kit Seal kit comments DG3V-8/ DG5V SNDRD 10 Design F3 IV. Size 10 (D10) olt kit (metric) Seal kit Seal kit comments DG3V-10/ DG5V SNDRD 10 Design F3 Direction Control Stak Valves I. Size 2 (D02) olt kit (metric) Seal kit Seal kit comments DGMC DGMR DGMR DGMX DGMC-2 Not available DGMDC DGMFG DGMFN DGMFD II. Size 3 (D03) olt kit (metric) Seal kit Seal kit comments DGMC DGMR DGMR DGMX-3 Not available DGMDC DGMC DGMFN III. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DGMC DGMR DGMR DGMX2-5 Not available DGMDC DGMC DGMFN EON Industrial Valve Catalog E-VVI-SS001-E October

4 Subplates and Connection lates for Four-ort Directional Valves ISO 4401, 02/03/05/07/08 General Description his range of subplates and auxiliary connection plates offers an economical way of mounting the range of Vickers directional control valves and associated stackable auxiliary valves. Size 02 he 2 to 6 multi-station subplates, available on sizes 02 and 03 provide very compact control assemblies when used together with Vickers SystemStakM valves. Size 03 he varied maximum pressure ratings of this current range of subplates, etc., are clearly indicated in the Schedule of lates and Subplates for each size. lates having machined O-seal recesses are supplied complete with O-seals. ll Vickers 02 and 03 valves and auxiliary plates are fitted with a location pin to ensure correct orientation of the mounting surfaces. When a subplate is not used, a machined pad must be provided for the valve mounting. his pad must be flat within 0,01 mm per 100 mm ( per 1 ) and smooth within 0,8 μm (32 μn), over the area designated in the appropriate ISO 4401 standard. Size 02 Size 05 Size 07 X Size 08 X Size 10-4 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

5 able of Contents Size 02 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-2--1* DGM-2-C1-1* DGM-2-C2-1* DGM-2-1-1*-R DGM-2-1-1*-S DGM-2-2-1*-R DGM-2-2-1*-S DGOM-2-1*-R DGM R DGM S DGM-2-3-1*-R DGM-2-3-1*-S DGMS-2-1E-1*-R DGMS-2-1E-1*-S DGMS-2-2E-1*-R DGMS-2-2E-1*-S DGMS-2-3E-1*-R DGMS-2-3E-1*-S DGMS-2-4E-1*-R DGMS-2-4E-1*-S DGMS-2-5E-1*-R DGMS-2-5E-1*-S DGMS-2-6E-1*-R DGMS-2-6E-1*-S Mounting Surface to ISO 4401 lanking plate Cast iron 0,24 (0.53) Crossover plate -; - Cast iron 0,21 (0.46) Crossover plate -; - Cast iron 0,21 (0.46) apping plate, ports and Cast iron 0,28 (0.62) apping plate, ports and Cast iron 0,28 (0.62) Orifice plate Cast iron 0,12 (0.27) daptor plate, DG4M4 to size 02 Cast iron 0,6 (1.2) daptor plate, size 03 to 02 Cast iron 0,43 (0.95) Single-station subplate; side ports,,, luminium 0,13 (0.29) Size 2 DG4M4 Size 2 Size 3 Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 2-station luminium 1,36 (3.0) 3-station luminium 1,85 (4.1) Valve station 1 Valve stations Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 4-station luminium 2,36 (5.2) 5-station luminium 2,87 (6.3) 6-station luminium 3,37 (7.4) 2 2 Valve station 1 Valve stations * Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. EON Industrial Valve Catalog E-VVI-SS001-E October

6 able of Contents Size 03 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-3--1* DGM-3-C1-1* DGM-3-C2-1 * DGM-3-1-1*- DGM-3-1-2*-S DGM-3-2-1*- DGM-3-2-2*-S DGVM-3-1*-R DGVM-3-1*-S KDGVM-3-1*-R KDGVM (SE/UNF ports) DGMS-3-1E-1*-R DGMS-3-1E()-1*-S DGM *-R DGM * (UNC valve mounting bolts) DGMS-3-2E-1*-R DGMS-3-2E(X)-1*-S DGMS-3-3E-1*-R DGMS-3-3E(X)-1*-S DGMS-3-4E-1*-R DGMS-3-4E-1*-S DGMS-3-5E-1*-R DGMS-3-5E-1*-S DGMS-3-6E-1*-R DGMS-3-6E-1*-S Mounting Surface to ISO 4401 lanking plate Cast iron 0,5 (1.1) Crossover plate -; - Cast iron 0,5 (1.1) Crossover plate -; - Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) Single-station subplate; rear ports,,, Cast iron 1,3 (2.9) Single-station subplate; rear ports,,, ; side port Cast iron 1,3 (2.9) Single-station subplate; side ports,,, Cast iron 1,3 (2.9) daptor, size 05 to 03 Cast iron 0,6 (1.3) Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 2-station Cast iron 4,0 (8.8) 3-station Cast iron 5,5 (12.1) Size 03 Size 05 Valve station 1 Valve station u u 2 2 u hrough-connection and ports on types DGMS-3-2EX-1*-* and DGMS-3-3EX-1-*. Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 4-station Cast iron 7,0 (15.4) 5-station Cast iron 8,5 (18.7) 6-station Cast iron 10,0 (22.0) Valve station 1 Valve station *Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R or = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. -6 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

7 able of Contents Size 05 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-5--1* 315 bar (4500 psi) DGM-5-C1-1* 315 bar (4500 psi) DGM-5-C2-1* 315 bar (4500 psi) DGM-5-1-1*- 315 bar (4500 psi) DGM-5-2-1*- 315 bar (4500 psi) DGM-5-3-1*- 315 bar (4500 psi) DGM-5-1*-R DGM-5-1*-S 210 bar (3000 psi) DGSM-01-2* bar (3000 psi) DGSME-01-2*-8 EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R 210 bar (3000 psi) 280 bar (4000 psi) KDGSM * (SE/UNF ports) KDGSM * (1 2 SF ports) KDGSM * (3 4 SF ports) 210 bar (3000 psi) Mounting Surface to ISO 4401 lanking plate Cast iron 2,9 (6.4) Crossover plate -; - Cast iron 2,9 (6.4) Crossover plate -; - Cast iron 2,9 (6.4) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports, and Cast iron 0,5 (1.1) daptor plate for pilot ports X and Cast iron 1,4 (3.1) X Single-station subplate; side ports,,, Cast iron 2,0 (4.4) Single-station subplate; rear ports,,, Cast iron 2,0 (4.4) Single-station subplate; rear ports,,, ; and port (side or rear) Cast iron 1,3 (2.9) Single-station subplate; rear ports,,, plus X and Cast iron 2,0 (4.4) X 315 bar (4500 psi) 280 bar (4000 psi) EKDGSM-01-1*-R EDGSM-03-1*-R EDGSM-03X-1*-R EDGSM-03X-1*-S 210 bar (3000 psi) * Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S or 8 suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R or = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. EON Industrial Valve Catalog E-VVI-SS001-E October

8 able of Contents sizes 07 and 08 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure Mounting Surface to ISO 4401 Single-station subplate Cast iron 3,8 (8.4) Cast iron 3,8 (8.4) Cast iron 6,1 (13.4) Cast iron 5,0 (11) Cast iron 5,0 (11) Cast iron 13 (28.6) X DGSM-04 EDGVM-7X EDGVM-7/7Z DGSM-8 EDGVM-8X EDGVM-8/8Z 210 bar (3000 psi) 350 bar (5000 psi) 350 bar (5000 psi) 210 bar (3000 psi) 350 bar (5000 psi) 350 bar (5000 psi) Operating Data Maximum flow rates Hydraulic fluids emperature limits Mounting attitude No functional limitations: dependent on valves used Compatible with all fluids recommended for Vickers sizes 02, 03, 05, 07, and 08 valves s for valves, subject to limits: 20oC to 70oC ( 4oF to 158oF) No restrictions, other than for valves fitted olt Kits for Mounting Valves Valve Size olt hreads Metric Inch orque (threads lubricated) M5-6H M5-6H M6-16H M10 M6 M12-6H M20 #10-24 UNC-2 #10-24 UNC UNC UNC UNC UNC-2 3/4-10 UNC Nm (44-62 lbf in) 7-9 Nm (62-79 lbf in) 9-14 Nm (7-10 Ib.ft.) Nm (36-44 Ib.ft) 9-14 Nm (7-10 Ib.ft.) Nm (79-94 Ib.ft.) Nm ( lb.ft.) Note: If not using Vickers recommended bolt kits, bolts used should be to ISO 898 class 12.9 or better. Use lower torque figures only when specified, e.g. for valves with lower maximum pressure rating. olt extenders available for use with size 05 valves cannot be used with size 05 auxiliary plates featured in this catalog. -8 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

9 Mounting surfaces to ISO 4401 (size 02) Dimensional olerances Dimensional tolerance on interface drawings is ± 0,2 mm (± ) except where otherwise stated. ISO 4401 specifies inch conversion to ± Conversion from Metric ISO 4401 gives dimensions in mm. Inch conversions are accurate to 0.01 unless otherwise stated. Mounting olt appings ISO 4401 gives metric thread tappings. lternative UNC tappings are Vickers recommendations that allow these plates and associated valves to be used up to their recommended maximum pressures, when using Vickers recommended mounting bolt kits, or bolts of an equivalent strength (see catalog 2314 Fixing olt Kits ). It is recommended that Customer s own manifold blocks for UNC bolts should be tapped to the minimum depths given in the footnotes. Vickers Standard Size 02 Interface his interface conforms to ISO ,1 (1. 97) min. 26,5 (1.04) 24,0 (0.95) 19,7 (0.78) 12, 0 (0.47) 2,25 (0.09) 4,3 (0.17) 0,75 (0.03) 22,5 (0.88) 20,25 (0.8) 17,75 (0.7) 11,25 (0.44) 23,25 (0.92) 35,2 (1.39) min. 37,5 (1.48) min. 4 holes, see table for thread options 4 ports Ø 4,75/4,90 (0.187/0.193 dia) Ø 3,40/3,55 x 4,3 deep (0.134/0.140 dia x 0.17 deep) for locating pin Mounting olt apping Options hread Metric M5-6H Inch #10-24 UNC-2 Min. tapping depth for subplates/manifolds in Steel Cast iron 12,3 (0.484) 12,3 (0.484) 12,6 (0.496) 14,9 (0.587) luminium 12,3 (0.484) 14,9 (0.587) Note: his dimension gives the minimum space required for a valve with this mounting surface. he dimension is also the minimum center-to-center pitch of mounting surfaces on a manifold block. EON Industrial Valve Catalog E-VVI-SS001-E October

10 Mounting surfaces to ISO 4401 (size 02) DGM-2--1* lanking late 3rd angle projection Ø 5,75 (0.226 dia.) 20,0 (0.78) 10,0 (0.39) 37,0 (1.46) 35,0 (1.38) Ø 9,0 (0.354 dia.) 50,0 Ø 3,0 (1.97) (0.12 dia.) Nameplate 3,0 (0.12) DGM-2-C*-1* Crossover late Ø 5,75 (0.226 dia.) 20,0 (0.78) 10,0 (0.39) 37,0 (1.46) 35,0 (1.38) Ø 9,0 (0.354 dia.) 50,0 (1.97) Ø3, 0 (0.12 dia.) Nameplate 3,0 (0.12) DGM-2-C1-1* (-, -) DGM-2-C2-1* (-, -) -10 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

11 Mounting surfaces to ISO 4401 (size 02) DGM-2-*-1*-* apping lates 20,0 (0.78) 2 tapped ports for DGM-2-*-1* -R, G 1 / 8 ( 1 / 8 SF) for DGM-2-*-1* -S, 7 / UNF-2 (SE) (for 1 / 4 O.D. tubing) 37,0 (1.46) 35,0 (1.38) 0, 5 (0.02) Ø 3, 0 (0.12 dia.) 60,0 (2.36) 50,0 (1.97) Nameplate 3,0 (0.12) 0,5 (0.02 ) 25,0 (0.98) DGM-2-1-1*-* (orts and ) DGM-2-2-1*-* (orts and ) DGOM-2-1*-R Orifice late ort Restrictor lugs Ø 5,5 (0.216 dia.) 20,0 (0.78) 8,0 (0.31) 37,0 (1.46) 35,0 (1.38) Restrictor plugs are available for use inports,, and. hese can be used for restricting flow or for circuit dampening. Restrictor plugs are not recommended for use above 210 bar (3000 psi) system pressure. 50,0 (1.97) M5 x 0,8-6H Code Orifice diameter art number *00 lank ,0 (0.35) Ø 3,0 (0.12 dia.) 3,0 (0.12) *05 0,5 (0.02) *06 0,6 (0.024) *08 0,8 (0.030) *10 1,0 (0.040) *12 1,2 (0.047) *15 1,5 (0.060) *18 1,8 (0.071) *20 2,0 (0.080) *23 2,3 (0.090) *,, or as required. vailable in multiples of 25 per part number. EON Industrial Valve Catalog E-VVI-SS001-E October

12 Mounting surfaces to ISO 4401 (size 02) ISO 02 daptor late DGM R DGM S When replacing a DG4M4, this adaptor plate has been designed in line with our range of subplates and auxiliary plates. wo versions are offered: S SE-UNC ports and/or UNC attaching bolt tappings and/or orifice plugs. R ISO 228 (SF) ports and/or metric attaching bolt tappings and/or orifice plugs. 24,0 (0.94) 10,5 (0.41) 27,0 (1.06) 10,0 (0.39) 51,0 (2.00) 34,95 (1.37) 6,75 (0.26) 24,0 (0.94) 9,3 (0.37) 28,5 (1.12) 58,0 (2.28) 22,5 (0.88) Centerline of DG4V2 valve Centerline of DG4M4 valve -12 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

13 Mounting surfaces to ISO 4401 (size 02) DGM-2-3-1*-R (Metric olt appings) DGM-2-3-1*-S (UNC olt appings) daptor late, Size 03 to 02 For pressures up to Size 02 valves can frequently be used in place of size 03 valves, or generally where the system flow rate is within that of size 02 valves. he DGM-2 adaptor plate bolts to an existing size 03 interface and provides a size 02 mounting face for the smaller valve. Size 2 Size (0.03) 46,0 (1.81) 23,25 (0.92) 4,25 (0.17) 23,0 (0.9) 10,0 (0.39) 48,0 (1.9) 32,5 (1.279) 6,75 (0.26) 60,0 (2.36) 7,0 (0.28) 24,0 (0.95) Ø 10,0 (0.39 dia.) Ø5,75 (0.226 dia.) 9,75 (0.38) 40,5 (1.59) 22, 5 (0.88) 4 holes for valve mounting bolts (see table) 0,75 (0.03) 31,0 (1.22) Size 02 Mounting Face Size 03 Mounting Face (ISO 4401 Size 03) Model DGM-2-3-1*-R DGM-2-3-1*-S Valve mounting bolt tappings M5 x 12,3 (0.48) deep #10-24 UNC x 14,9 (0.587) deep DGMS-2-1E-1*-* Single-Station Subplate, Side apped orts 34,5 (1.36) 20,0 (0.78) 6,5 (0.26) Ø10,0 (0.39 dia.) 75,0 (2.95) 62,0 (2.44) 6,5 (0.26) Ø 5,7 5 (0.226 dia.) 62,0 (2.44) 75,0 (2.95) Model cod e stamped here 18,5 (0.73) Model orts,,, tappings Valve mounting bolt tappings DGM-2-3-1*-R G3 8 (3 8 SF) x M5 x 12,3 (0.48) deep 12,0 (0.47) deep DGM-2-3-1*-S UNF-2 x 14,3 (0.56) deep #10-24 UNC x 14,9 (0.587) deep 4 holes for valve mounting bolts (see table) 4 ports (see table) EON Industrial Valve Catalog E-VVI-SS001-E October

14 Mounting surfaces to ISO 4401 (size 02) DGMS-2-*E-1*-* Multi-Station Subplates (4-station model illustrated) Valve Station Valve Stations Valve Station 1 Valve Stations ,5 (2.93) Ø 5,75 (0.226 dia. thru) 75,0 (2.95) 37,5 (1.47) 37,5 (1.47) 37,5 (1.47) 37,5 (1.47) 32,8 (1.29) Ø10,0 (0.39 dia.) 34,5 (1.36) 20,25 (0.8) 60,0 (2.36) 20,0 (0.78) 37,5 (1.47) 6,0 (0.24) 37,5 (1.47) 2 ports and on all models, tapped per model code, (see table 2) 4 holes per station for valve mounting bolts, tapped per model code (see table 3) 2 ports, and through drilled end-to-end, tapped per model code (see table 2) and ports at each station, tapped per model code (see table 2) 17,25 (0,68) 2 holes for attaching bolts, tapped per model type (see table 3) Model code stamped here 40,0 (1.57) able 1: Dimensions Model DGMS-2-2E-1*-* DGMS-2-3E-1*-* DGMS-2-4E-1*-* DGMS-2-5E-1*-* DGMS-2-6E-1*-* 102 (4.02) 140 (5.5) 178 (7.0) 216 (8.5) 254 (10.0) 90 (3.54) 125 (4.92) 165 (6.5) 200 (7.9) 240 (9.45) able 3: Mounting olt appings Model Valve mounting bolts Manifold rear-mount holes DGMS-2-1E-1*-R M5 x 12,3 (0.48) deep M8 x 1,25-6H DGMS-2-1E-1*-S #10-24 UNC x 14,9 deep UNC-2 able 2: ort appings Model orts, orts, DGMS-2-1E-1*-R G1 2 (1 2 SF) G3 8 (3 8 SF) x 12,0 (0.47) deep DGMS-2-1E-1*-S UNF UNF-2 x 14,3 (0.56) deep -14 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

15 Mounting surfaces to ISO 4401 (size 03) Vickers Standard Size 03 Interface his interface conforms to: ISO plus location pin hole NSI/93.7M (and NF) size 03 CEO R35H , plus location pin hole DIN Form 6 plus location pin hole 4 holes, M5-6H x 12 (0.47) min. full thread depth 30,2 (1.18) 21,5 (0.85) 12,7 (0.5) 0,75 0,1 ( ) 15,5 (0.61) 25,9 (1.01) 31,0 0,1 ( ) 4 ports Ø 6,3 (0.25 dia). For all Vickers size 03 valves this diameter may be increased to Ø 7,5 (0.29) Ø 4,0 x 4,3 min. depth (0.16 dia x 0.17) for locating pin 5,1 (0.20) 70 (2.75) min. 31,75 0,1 ( ) 7,5 (0.29) 40,5 0,1 ( ) 48 (1.89) min. #10-24 UNC-2 optional. Interface with dditional Drain ort he interface conforms to Vickers standard, plus hole ypically used for proportional and other valves requiring an additional drain port, e.g.: KFDG4V-3 KFG4V-3 KSDG4V-3 25,3 (0.99) 46,5 (1.83) Ø4,0 (0.16 dia) EON Industrial Valve Catalog E-VVI-SS001-E October

16 Mounting surfaces to ISO 4401 (size 03) DGM-3--1* lanking late 10,0 (0.4) 73,0 (2.9) Nameplate 46,0 (1.8) 22,0 (0.9) 24,4 (1.0) DGM-3-C*-1* Crossover late he sealing faces shown are for 11-design. For 10-design the sealing face is the same as for DGM-3--1* (transfer passages are drilled). Ensure correct design number is quoted when ordering spare seals. 4 holes Ø 5,6 (0.22 dia) counterbored to Ø9,5 (0.374 dia) 10,0 (0.4) 75,0 (3.0) 46,0 (1.8) 48,5 (1.9) Nameplate 22,0 (0.9) DGM-3-C1-1* DGM-3-C2-1* -16 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

17 Mounting surfaces to ISO 4401 (size 03) DGM-3-1-**-1* apping late, orts and 4 holes Ø5,6 (0.22 dia) 2 tapped ports: For DGM-3-1-1*-, G1/8 ( 1/8 SF) For DGM-3-1-2*S, 7/16-20 UNF-2 (SE) (for 1/4 O.D. tubing) 75,0 (3.0) Nameplate 46,0 (1.8) 48,4 (1.9) 20,0 (0.78) DGM-3-2-**-1* apping late, orts and 4 holes Ø5,6 (0.22 dia) 2 tapped ports: For DGM-3-2-1*-, G1/8 ( 1/8 SF) For DGM-3-2-2*-S, 7/16-20 UNF-2 (SE) (for 1/4 O.D. tubing) 75,0 (3.0) Nameplate 46,0 (1.8) 48,4 (1.9) 20,0 (0.78) EON Industrial Valve Catalog E-VVI-SS001-E October

18 Mounting surfaces to ISO 4401 (size 03) Single-Station Subplates, Rear and Side apped orts 4 holes Ø5,6 (0.22 dia) spotfaced to Ø 13,0 (0.51 dia) 4 system connections for rear-entry models, see table 4 system connections for side-entry models, see table 35,0 (1.38) 84,0 (3.3) 20,0 (0.79) 57,25 (2.25) 35,0 (1.38) 12,75 (0.5) 12,75 (0.5) 36,0 (1.42) 59,25 (2.33) 16,3 (0.64) Rear mounting face 16,0 (0.63) ort (see KDGVM-3 models in tables) 72,0 (2.83) 15,75 (0.62) 19,75 (0.78) 6,0 (0.24) 72,0 (2.83) 6,0 (0.24) 84,0 (3.3) 4 holes tapped according to model type (see table): For models with SF ports, M5-6H x 12 (0.47) deep For models with SE ports, #10-24 UNC-2 x 12,7 (0.5) deep ort hreads Model SF ports/m5 mounting bolts: DGVM-3-1*-R KDGVM-3-1*-R DGMS-3-1E-1*-R orts,,, t rear or side Rear Rear Side G3 8 (3 8 SF) x 12,0 (0.47) deep G3 8 (3 8 SF) x 12,0 (0.47) deep G3 8 (3 8 SF) x 12,0 (0.47) deep orts _ G1 8 (1 8 SF) x 12,0 (0.47) deep _ SE ports/#10-24 UNC mounting bolts: DGVM-3-1*-S KDGVM * DGMS-3-1E-1*-S DGMS-3-1E-1*-S Rear Rear Side Side UNF-2 x 14,3 (0.56) deep (SE) UNF-2 x 14,3 (0.56) deep (SE) UNF-2 x 14,3 (0.56) deep (SE) UNF-2 x 12,7 (0.5) deep (SE) _ UNF-2 x 11,6 (0.46) deep (SE) s 11,5 (0.45) from rear mounting face to port center line. -18 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

19 Mounting surfaces to ISO 4401 (size 03) DGM *-R (Metric olt appings) DGM * (UNC olt appings) daptors, Size 05 to 03 For pressures up to 210 bar (3000 psi) Size 3 valves can frequently be used in place of size 5 valves, typically for pilot control functions, or generally where Size 03 Size 05 system flow rate is within that of the size 3 valves. he DGM-3-01 adaptor bolts n to an existing size 05 interface and provides a size 03 mounting face for the smaller valve. 4 holes Ø 7,1 (0.281 dia), counterbored Ø11,1(0.438 dia) 70,00 (2.75) 31,0 (1.22) 14,2 (0.56) 28,4 (1.12) 21,0 (0.83) 5,3 (0.21) 40,5 (1.59) 54,0 (2.12) 90,4 (3.56) Standard port dditional port 18,3 (0.72) 31,75 (1.25) 4 holes tapped: For DGM *-R, M5-6H x 12 (0.47) deep For DGM *, #10-24 UNC-2 x 12,7 (0.5) deep 46,0 (1.81) 0,75 (0.03) 12,0 (0.47) Size 03 Mounting Surface Size 05 Mounting Surface Seals included Supplied complete with bolts for mounting to size 05 interface: M6 bolts with type DGM *-R 1 / 4-20 UNC bolts with type DGM *. EON Industrial Valve Catalog E-VVI-SS001-E October

20 Mounting surfaces to ISO 4401 (size 05) DGMS-3-*E(X)-1*-* Multi-Station Subplates (3-station model illustrated) Valve station 1 Valve stations 2 to hese two ports are: resent in 4-, 5- and 6-station models Optional in 2- and 3-station models, by specifying DGMS-3-2 EX-1*-* or DGMS-3-3 EX-1*-* respectively 2 holes Ø 5,6 (0.22 dia) counterbored to Ø 11,1 (0.438 dia) t each station, 4 holes tapped according to model type (see table): For models with SF ports, M5-6H x 12,0 (0.47) deep. For models with SE ports, #10-24 UNC-2 x 12,7 (0.5) deep. and ports tapped according to model type: For DGMS-3-*E(X)-1*- R: G 1 / 2 ( 1 / 2 SF) For DGMS-3-*E(X)-1*- S: 3 / 4-16 UNF-2 (SE) 68,0 (2.68) 34,0 (1.34) 15,0 (0.6) 38,0 (1.5) 68,0 (2.68) 6,0 (0.24) 15,0 (0.6) 38,0 (1.5) 50,0 (1.97) 50,0 (1.97) 35,0 (1.38) 60,0 (2.36) effective bolt length and ports at each station tapped according to model type: For DGMS-3-*E(X)-1*- R: G 3 / 8 ( 3 / 8 SF) For DGMS-3-*E(X)-1*- S: 3 / 4-16 UNF-2 (SE) Model DGMS-3-2E(X)-1*-* DGMS-3-3E(X)-1*-* DGMS-3-4E-1*-* DGMS-3-5E-1*-* DGMS-3-6E-1*-* 121 (4.8) 171 (6.8) 221 (8.7) 271 (10.7) 321 (12.7) 108 (4.25) 158 (6.22) 208 (8.19) 258 (10.15) 308 (12.12) hrough-connection and ports on types DGMS-3-2EX-1*-* and DGMS-3-3EX-1*-* -20 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

21 Mounting surfaces to ISO 4401 (size 05) Vickers Standard Size 05 Interface his interface conforms to: ISO NSI/93.7M (and NF) size 05 CEO R35H DIN Form 10 16,7 (0.66) 37,3 (1.47) 27,0 (1.06) 50,8 (2.0) 4 holes, M6-6H x 16 (0.63) min. full thread depth 3,2 (0.12) 6,3 (0.25) 21,4 (0.84) 32,5 (1.28) 46,0 0,1 (1.81 0,004) 69,0 (2.72) min. 5 ports Ø 11,2 (0.44 dia) including optional tank port n 1/4-20 UNC-2 optional. 54,0 0,1 ( ) 90,0 (3.54) min. Optional port ( ) Interface with dditional Drain ort he interface conforms to Vickers standard, plus hole ypically used for proportional and other valves requiring an additional drain port, e.g.: KFDG4V-5 KFG4V-5 Interface with dditional ilot orts X and he interface conforms to Vickers standard, plus holes X and ISO ypically used for two-stage directional and proportional control valves requiring additional pilot ports, e.g.: DG5V-5 KDG5V-5 KFDG5V-5 KHDG5V-5 0,5 (0.02) 11,0 (0.433) 8,0 (0.315) 11,0 (0.433) X 62,0 (2.44) Ø 3,0 (0.12 dia) 2 holes Ø 6,3 (0.25 dia) max. EON Industrial Valve Catalog E-VVI-SS001-E October

22 Mounting surfaces to ISO 4401 (size 05) DGM-5--1* lanking late 4 holes Ø 7,14 (0.28 dia) 72,0 (2.84) 70,0 (2.8) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate DGM-5-C*-1* Crossover late 4 holes Ø 7,14 (0.28 dia) lugs each end, G 1 / 2 ( 1 / 2 SF ) 19,5 (0.77) 72,0 (2.84) 70,0 (2.8) 5,0 (0.2) 116,0 (4.6) Nameplate 5, 0 (0.2) 37, 0 (1.46) 2,0 (0.08) sealplate Model Dimension Dimension DGM-5-C1-1* 25,0 (1.0) 40,0 (1.6) DGM-5-C2-1* 40,0 (1.6) 25,0 (1.0) -22 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

23 Mounting surfaces to ISO 4401 (size 05) DGM-5-1-1*- apping late orts and 4 holes Ø 7,14 (0.28 dia) 18,0 (0.71) 72,0 (2.84) 70,0 (2.8) 31,0 (1.2) 2 ports, G 1 / 2 ( 1 / 2 SF) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate orts and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. DGM-5-2-1*- apping late orts and 4 holes Ø 7,14 (0.28 dia) 18, 0 (0.71) 72,0 (2.84) 70,0 (2.8) 45,0 (1.8) 28,0 (1.1) 2 ports, G 1 / 2 ( 1 / 2 SF) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate orts and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. EON Industrial Valve Catalog E-VVI-SS001-E October

24 Mounting surfaces to ISO 4401 (size 05) DGM-5-3-1*- apping late orts, and 4 holes Ø 7,14 (0.28 dia) 18,0 (0.71) 72,0 (2.84) 70,0 (2.8) 31,0 (1.2) 3 ports, G 1 / 2 ( 1 / 2 SF ) 116,0 (4.6) orts, and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. Nameplate 37,0 (1.46) 2,0 (0.08) sealplate DGM-5-1*-*, X and ort daptor lates rovides for external connections to additional pilot ports X and when these ports are not present in subplate/manifold block. ypically used for two-stage directional and proportional valves: DG5V-5 KDG5V-5 KFDG5V-5 KHDG5V-5 X and ports, see table 4 holes Ø 7,14 (0.28 dia) X 44,0 (1.7) X 70,0 (2.8) 72,0 (2.84) Nameplate 32,0 (1.25) 102,0 (4.0) Model DGM-5-1*-R DGM-5-1*-S X and port thread G1 4 (1 4 SF) x 11,0 (0.43) full thread depth UNF x 12,7 (0.5) full thread depth -24 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

25 Mounting surfaces to ISO 4401 (size 05) Subplate with Side orts,,, Maximum ressure 210 bar (3000 psi) Model type: DGSME-01-2*-8 4 holes Ø 10.8 (0.42 dia) through, softfaced Ø 17,5 (0.66 dia) 18,3 (0.6) 12, 7 (0.5) 101,6 (4.0) 79,4 (3.12) 39,6 (1.6) 4 ports,,, : 3 / 4-16 UNF-2 x 14,3 (0.56) full thread depth 69,0 (2.7) 47,7 (1.9) 47,7 (1.9) 68,3 (2.7) 23,1 (0.9) 91,95 (3.62) 114,3 (4.5) 23,1 (0.9) 38,1 (1.5) 33,0 (1.3) 4 holes tapped 1 / 4-20 UNC-2 x 12,7 (0.5) deep EON Industrial Valve Catalog E-VVI-SS001-E October

26 Mounting surfaces to ISO 4401 (size 05) Subplates with Rear orts,,, Maximum ressure 210 bar (3000 psi) Model types: DGSM-01-2*-8 KDGSM * (with rear port ) Maximum ressure 280 bar (4000 psi) Model types: EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R (with side port ) Rear port, KDGSM only: G 1 / 8 ( 1 / 8 SF) x 12,0 (0.47) full thread depth C 101,6 (4.0) 11,5 (0.45) 4 holes Ø 10,8 (0.42 dia) through, spotfaced Ø 17,5 (0.66 dia) 79,4 (3.12) 12,7 (0.5) 11,2 (0.44) 114,3 (4.5) W K E 68,3 (2.7) 47,5 (1.5) 92,1 (3.62) 69,0 (2.7) 68,3 (2.7) F 11,2 (0.44) 23,1 (0.9) J H N M 5,6 (0.22) 90,4 (3.56) G Side port, EKDGSM-01 only : 9 / UNF-2 x 12,7 (0.5) full thread depth 4 holes tapped according to model type: For DGSM-01 and KDGSM-5 models (UNC port threads), 1 / 4-20 UNC-2 x 12,7 (0.5) deep. For EDGSM-01(*) and EKDGSM-01 models (SF port threads), M6-6H x 15,8 (0.62) deep. orts,,, hreads Model 210 bar (3000 psi) DGSM-01-2*-8 KDGSM * 280 bar (4000 psi) EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R ort thread UNF-2 x 14,0 (0.56) full thread depth G1 4 (1 4 SF) x 12,2 (0.48) full thread depth G3 8 (3 8 SF) x 12,2 (0.48) full thread depth G1 2 (1 2 SF) x 15,0 (0.59) full thread depth Dimensions Model C E F G H J K M N W 210 bar (3000 psi) DGSM-01-2*-8 KDGSM * 45,2 (1.78) 42,1 (1.66) 19,0 (0.75) 68,3 (2.69) 45,2 (1.78) 23,8 (0.94) 42,1 (1.7) 31,8 (1.25) 23,9 (0.94) 57,1 (2.25) 280 bar (4000 psi) EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 38,1 (1.5) 40,5 (1.59) 40,5 (1.59) 40,5 (1.59) 13,5 (0.53) 13,5 (0.53) 9,9 (0.39) 9,9 (0.39) 65,5 (2.58) 67,5 (2.66) 70,6 (2.78) 70,6 (2.78) 41,7 (1.64) 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 10,3 (0.41) 12,7 (0.5) 10,7 (0.42) 10,7 (0.42) 40,9 (1.61) 40,5 (1.59) 40,5 (1.59) 40,5 (1.59) 31,8 (1.25) 31,8 (1.25) 31,8 (1.25) 36,5 (1.44) 23,9 (0.94) 23,9 (0.94) 28,6 (1.13) 28,6 (1.13) 62,7 (2.47) 68,6 (2.7) 72,6 (2.86) 72,6 (2.86) -26 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

27 Mounting surfaces to ISO 4401 (size 05) Subplate with Side orts,,,, Maximum ressure 315 bar (4500 psi) Model type: KDGSM * KDGSM * Recommended panel cut-out to clear fittings, Ø 108,0 (4.25 dia) 89,0 (3.5) 75,0 (3.0) ort, G 1 / 4 ( 1 / 4 SF) x 12,0 (0.47), spotfaced to Ø 24,0 (0.94 dia) 42, 0 (1.7) ort, Ø 4,0 (0.16 dia) 80,0 (3.15) 13, 0 (0.51) 4 holes Ø 10,5 (0.41 dia) 46,0 (1.81) 47,5 (1.9) 77,5 (3.1) Z 1,0 (0.04) 23, 0 (0.9) 67,0 (2.6) 115,0 (4.6) 92,0 (3.62) 5,0 (0.2) 40,0 (1.6 ) 12,5 (0.5) 17,0 (0.7) orts,,,, Ø10,5 (0.41 dia) 88,0 (3.5) 120,0 (4.8) 4 holes M6 x 14,0 (0.55) full thread depth art Section - orts,,, Model thread Z diameter KDGSM * KDGSM * G1 2 (1 2 SF) x 14,0 (0.55) full thread depth G3 4 (3 4 SF) x 16,0 (0.63) full thread depth 30,0 (1.18) 33,0 (1.3) EON Industrial Valve Catalog E-VVI-SS001-E October

28 Mounting surfaces to ISO 4401 (Sizes 07 and 08) Vickers Standard Size 07 Interface his interface conforms to: ISO NSI/93.7M (and NF) size 07 CEO R35H DIN Form 16 1,6 0,1 ( ) 15,9 (0.63) 18,3 (0.72) 101,6 0,1 ( ) 88,1 (3.47) 76,6 (3.016) 65,9 (2.59) 50,0 (1.97) 34,1 (1.34) 2 holes Ø4,0 (0.157 dia) x 8,0 (0.31) min. dept h 4 holes M10 x 17,0 (0.67) min. full thread depth 71,5 0,1 ( ) 69,8 0,1 ( ) 57,2 (2.25) 55,6 (2.19) 34,9 (1.38) 14,3 (0.56) X 95,0 (3.74) min. 11,0 (0.43) 130,0 (5.12) min. n 3 / 8-16 UNC optional. 1 / 4-20 UNC optional. 3 holes (ports, X, ) Ø 6,3 (0.25 dia) max. 4 holes (ports,,, ) Ø 17,5 (0.69 dia) max. 2 holes M6-6H x 17,0 (0.67) min. full thread depth Vickers Standard Size 08 Interface his interface conforms to: ISO NSI/93.7M (and NF) size 07 CEO R35H DIN Form 16 94,5 0,1 ( ) 77,0 (3.03) 53,2 0,1 ( ) 29,4 0,1 ( ) 130,2 0,1 ( ) 112,7 (4.437) 100,8 (3.968) 2 holes Ø 7,5 (0.295 dia) x 8,0 (0.31) min. depth orts X,: Ø 11,2 (0.44 dia) max. 17,4 (0.685) 19,0 (0.748) 17,5 (0.689) 5,6 (0.22) 4,8 0,1 ( ) 92,1 0,1 ( ) 74,6 (2.937) 73,0 (2.874) 46,0 (1.181) X 118,0 (4.65) min. 1 / 2-13 UNC optional. Vickers uses port for pressure-centered and other options not in high demand. ort : Ø 11,2 (0.44 dia) max. 153,0 (6.02) min. 6 holes, M12-6H x 20,0 (0.78) min. full thread depth orts,,, : Ø 23,4 (0.92 dia) max. -28 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

29 Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 350 bar (5000 psi) Maximum ressure orts,,,, X, DGSM-8-1*-** (UNF/SE ports; UNC mounting bolts) X 120,0 (4.73) 60,0 (2.36) 75,0 (2.95) 96,0 (3.78) 35,0 (1.38) 60,0 (2.36) 13,0 (0.51) 21,5 (0.85) 9,0 (0.35) 160,0 (6.3) 184,0 (7.25) 30,0 (1.18) X 150,0 (5.9) 140,0 (5.51) X 36,5 (1.44) 52,5 (2.07) 91,5 (3.6) 107,5 (4.23) 4 holes Ø 9,0 (0.35 dia) through, spotfaced Ø 14,5 (0.57 dia) 6 tapped holes for valve mounting, see table 29,0 (1.14) 61,0 (2.4) For port tappings according to model code, see table ort and olt hreads Model orts,,, orts, X, Mounting bolt tapping EDGVM-7-D-1*-R G1 (1 SF) x 19,0 (0.75) full thread depth G1 4 (1 4 SF) x 12,0 (0.47) full thread depth 4 x M10 2 x M6 EDGVM-7Z-D-1*-S UN-2 x 19,0 (0.75) full thread depth UNF-2 x 12,7 (0.5) full thread depth 4 x UNC 2 x UNC 33 EON Industrial Valve Catalog, Section September 2012 EON Industrial Valve Catalog E-VVI-SS001-E October

30 Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 210 bar (3000 psi) Maximum ressure DGSM-04-12S-2* (UNF/SE port threads; UNC mounting bolts) For up to 350 bar (3000 psi) Maximum ressure EDGVM-7X-D-1*-R (SF port threads; metric mounting bolts) X 140,0 (5.51) C D Ø 8,73 (0.344 dia) 25,0 (1.0) Ø 14,5 (0.57 dia) Ø 9,9 (0.389 dia) 12,6 (0.5) E 89,0 (3.5) 92,0 (3.62) 42,5 (1.67) X H G F 69,9 (2.75) 38,1 (1.5) 35,0 (1.38) 14,3 (0.65) M K DGSM-04 Only EDGVM-7X Only J 160,0 (6.3) For port tappings according to model code, see table ort and olt hreads Model orts,,, orts, X, Mounting bolt tapping DGSM-04-12S-2* 1-12 UNF-2 x 19,1 (0.75) full thread depth UNF-2 x 12,7 (0.5) full thread depth 4 x UNC 2 x UNC EDGVM-7X-D-1*-R G3 4 (3 4 SF) x 16,0 (0.63) full thread depth G1 4 (1 4 SF) x 12,0 (0.47) full thread depth 4 x M10 2 x M6 Dimensions Model C D E F G H J K M DGSM-04-12S-2* EDGVM-7X-D-1*-R 121,4 (4.78) 128,6 (5.06) 88,4 (3.48) 93,6 (3.68) 44,2 (1.74) 50,6 (1.99) 56,6 (2.23) 55,6 (2.19) 54,9 (2.16) 52,0 (2.05) 18,3 (0.72) 15,9 (0.63) 121,4 (4.78) 113,6 (4.47) 76,7 (3.02) 79,6 (3.13) 32,3 (1.27) 36,6 (1.44) -30 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

31 Installation dimensions in mm (inches) (sizes 07 and 08) For up to 350 bar (5000 psi) Maximum ressure orts,,,, X, EDGVM-8(*)-1*-R (SF port threads; metric mounting bolts) EDGVM-8-1*-S (UNF/SE port threads; UNC mounting bolts) orts,,,, X, and X EDGVM-8(*)-1*-R (SF port threads; metric mounting bolts) EDGVM-8-1*-S (UNF/SE port threads; UNC mounting bolts) his profile on model types EDGVM-8 and -8Z only ort, see table M orts,,,, see table F N G S X E D C X H R 4 holes Ø ( dia), see table ort X, see table K J 6 tapped holes for valve mounting, see table EDGVM-8(*)-D -1*-* models only ort, see table ort hreads, olt appings and Dimensions Mounting bolt orts,,, orts, X, Model tappings EDGVM-8(-D)-1*-R G3 4 x 16 (0.63) G1 4 x 12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8X(-D)-1*-R G1 x 19 (0.74) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8(-D)-1*-R G11 4 x 21 (0.82) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8(-D)-1*-S UN x UNF x ,1 (0.75) deep 12,7 (0.5) deep UNC-2 EDGVM-8Z(-D)-1*-R G11 2 x 22 (0.86) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep C D E F 54,8 (2.16) 49,6 (1.95) 50,5 (1.99) 50,5 (1.99) 50,5 (1.99) 78,6 (3.09) 73,4 (2.89) 74,2 (2.92) 74,2 (2.92) 74,2 (2.92) 102,4 (4.03) 107,5 (4.23) 128,0 (5.04) 128,0 (5.04) 128,0 (5.04) 126,2 (4.97) 131,4 (5.17) 151,8 (5.98) 151,8 (5.98) 151,8 (5.98) 160 (6.30) 160 (6.30) 185 (7.28) 185 (7.28) 185 (7.28) 74,6 (2.94) 74,6 (2.94) 103 (4.06) ) ) Dimensions Model G H J K M N R S Ø EDGVM-8(-D)-1*-R EDGVM-8X(-D)-1*-R EDGVM-8(-D)-1*-R EDGVM-8(-D)-1*-S EDGVM-8Z(-D)-1*-R 19 (0.75) 33 (1.30) 21 (0.83) 17,5 (0.69) 31 (1.22) 5,6 (0.22) 17,4 (0.685) 27 (1.06) 73 (2.87) 97 (3.82) (2.84) 35 (1.38) 45 (1.77) 119 (4.69) 160 (6.30) 181 (7.13) 202 (7.95) 92,1 (3.63) 130 (5.12) 204 (8.03) 232 (9.13) 10,8 (0.425) 13,5 (0.53) EON Industrial Valve Catalog E-VVI-SS001-E October

32 Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 210 bar (3000 psi) Maximum ressure orts,,,, X, DGSM-8-1*-** (UNF/SE ports; UNC mounting bolts) X 4 holesø 10,8 (0.42 dia), spotfaced Ø17,5 (0.68 dia) 134,9 (5.3) 1,5 (0.05) 40,0 (1.6) 41,3 (1.62) 168,0 (6.6) 67,5 (2.65) X 34,8 (1.4) 92,1 (3.62) 26,2 (1.03) X 79,2 (3.12) 124,0 (4.9) 68,3 (2.7) 111,1 (4.4) 10,6 (0.4) 25,4 (1.0) 32,0 (1.26) 111,1 (4.4) 136,6 (5.38) 4 holes tapped according to model type: For EDGSM-03(X)-1*-R models (SF ports): M6-6H x 16,0 (0.63) full thread depth For EDGSM-03X-1*-S models (UNC ports): ¼ -20 UNC-2 x 16,0 (0.63) full thread depth ort hreads Model orts,,, orts X, DGSM-8-1*-12 11/16-12 UN x 19,1 (0.75) deep 9/16-18 UNF x 12,7 (0.5) deep DGSM-8-1*-16 15/16-12 UN x 19,1 (0.75) deep 9/16-18 UNF x 12,7 (0.5) deep -32 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

33 Mounting surfaces to ISO 4401 (size 10) Millimeters (Inches ) machined pad must be provided for mounting. ad must be flat within 0,127 mm (.0005 inch) and smooth within 1,6 μm (63 microinch). Mounting bolts, when provided by customer, should be SE grade 7 or better. 44,4 (1.75) - ank connection 41,3 (1.62) 34,9 (1.38) 230,1 (9.06) 168,3 (6.62) 147,6 (5.81) 138,6 (5.46) 114,3 (4.50) 82,6 (3.25) 76,2 (3.00) 190,5 (7.50) - ressure connection 7,1 DI (.28 DI) ocation per ISO ,1 DI (.28 DI) ocation per NSI 93.7M-1986 M20 hread ( UNC hread - ilot valve drain connection 198,9 (7.83) 158,8 (6.25) 130,2 (5.12) 123,8 (4.88) 79,4 (3.12) W - External drain 11,2 DI (.44 DI) 2 places 31,8 DI (1.25 DI) 4-laces X - External pilot pressure connection 7,1 DI (.28 DI) ort connection ort connection Required for D pressure centered models only Subplates Subplates must be ordered separately. For 210 bar (3000 psi) applications, order Subplate DGSM-10-24S-11. Subplate not available for 350 bar (5000 psi) applications. Mounting olts olt kits must be ordered separately. Use olt Kit KDG Maximum recommended bolt torque is 210 lb. ft. (286 N.m). ort connection "X" - External pilotpressure connection UNF-2 HD.From rear (2 holes) n16.7 [.657](4 holes for mounting) 35.1 [1.38] [6.25] [4.87] [4.81] 36.6 [1.44] 28.5 [1.12] [12.0] [5.94] 30.7 [1.21] [5.81] [10.5] 38.1 [1.5] UNC-2 HD (6 HOES) ort connection ""-ressure connection 9.5(.375) Drill 26.2(1.03) Deep ""-ilot valve drain Connection (not required for Internally drained models) 44.5 [1.75] 22.9 [.90] [7.75] 28.6(1.125) Drill 22.4(.88) Deep (4 Holes) "" ank connection n28.6(1.125)(4 holes) System ports UN-2 HD. (From rear)(4 holes)-system connections 41.1 [1.62] 75.2 [2.96] [4.5] [6.62] [7.5] n7.1(.281)-7.9(.31) Deep (2 Holes for rest pins) 25.4 [1.00] EON Industrial Valve Catalog E-VVI-SS001-E October

34 Eaton Hydraulics usiness US one Oak Road Eden rairie, MN US el: Fax: Eaton Hydraulics usiness Europe Route de la ongeraie Morges Switzerland el: +41 (0) Fax: +41 (0) Eaton Hydraulics Group sia acific Eaton uilding 4 th Floor, No. 3 ane 280 inhong Rd. Changning District Shanghai China el: (+86 21) Fax: (+86 21) Eaton ll Rights Reserved rinted in US Document No. E-VVI-SS001-E October 2016

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description. Vickers ccessories Subplates and Connection lates for Four-ort Directional Valves ISO 4401, 02/03/05/07/08 General Description his range of subplates and auxiliary connection plates offers an economical

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Proportional Valves. Proportional Two-Stage Directional Valves

Proportional Valves. Proportional Two-Stage Directional Valves VICKERS roportional Valves roportional Two-Stage Directional Valves KHDG5V-5/7, 1 Series ressures to 3 bar ( psi) This product has been designed and tested to meet specific standards outlined in the European

More information

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules June 1996 G-459 VICKERS roportional Valves uxiliary Function Modules for roportional Valves Hydrostat, arallel-flow-ath, ilot Shuttle and Tapping Modules Functional Symbols For typical applications of

More information

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s H y d r a u l i c s Hydraulics Vickers TM roportional Directional Valves without Feedback h y d r a u l i c s We Manufacture This product has been designed and tested meet specific standards outlined in

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

Directional Controls

Directional Controls Vickers Directional Controls Solenoid Operated Directional Valves DGV-3 flows to 80 l/min (1 USgpm), * design DGV-3S flows to 0 l/min (10. USgpm), * design ISO 01, size 03; NSI/93.7M-D03 Rev 0/98 G-C-01

More information

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description Vickers SystemStak SystemStak Valves ISO 441 size 7; 315 bar (45 psi); up to 2 L/min (53 USgpm) General Description This range of stackable hydraulic controls are designed to be mounted under a size 7

More information

Pressure Relief Valves

Pressure Relief Valves VICKERS Pressure Relief Valves Unloading Relief Valves EURG1/2-06/10, 13 Design and EURT1/2-06/10, 12 Design Sectional Illustrations EURG* EURT* Basic Characteristics Mounting... Pipe or subplate mounting

More information

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series Contents Introduction General Description 3 Features and Benefits 3 Typical Section View

More information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s H y d r a u l i c s ydraulics Eaton Medium Duty Piston Pump h y d r a u l i c s Model 70122, 70422, 70423, and 70523 or -Flow Compensated Piston Pumps We Manufacture April 1997 Solutions S o l u t i o

More information

Sepehr Hydraulic Asia

Sepehr Hydraulic Asia Vickers Solenoid Operated Directional Valves Explosion Proof ATEX, UL, CSA Sepehr Hydraulic Asia DG4V-3S, X4 & X5 DG4V4-1, X5 Table of Contents Introduction General Description... 3 Features and Benefits...

More information

Directional Controls

Directional Controls VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

Functional Symbols and Application Notes

Functional Symbols and Application Notes Functional Symbols and pplication Notes Model Types KHDG5V Shown Simplified symbol Model Types KHDG5V Shown K()FDG5V symbols identical, but omit pilot-stage LVDTs Simplified symbol T T Detailed symbol

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) Vickers Vane Pumps VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) 5008.00/EN/0596/A A.25 Introduction From the

More information

General specifications 3 5 Applications, features, and benefits 3 Specifications 4

General specifications 3 5 Applications, features, and benefits 3 Specifications 4 able of contents Description age No. General specifications 3 5 pplications, features, and benefits 3 Specifications 4 rinciples of operation 6-7 ost-compensated circuit 7 re-compensated circuit 7 Order

More information

Eaton Heavy Duty Hydrostatic Transmissions

Eaton Heavy Duty Hydrostatic Transmissions Eaton Heavy Duty Hydrostatic Transmissions July, 1995 Ready Mix Concrete Troubleshooting Guide f Eaton Hydrostatic Transmissions used on Concrete Mixers Contents Introduction... 2 Typical Hydrostatic System...

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -

More information

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93 Vickers Vane Pumps Double Thru-drive Vane Pumps High speed, high pressure VQT Series for mobile equipment Released 7/93 612 Introduction Double VQT high performance pumps are fixed displacement units that

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax: GENERL FEURES SNDRD FEURES High ressure/ High Flow: 65 gpm/ psi ilot Operation: Main spool controlled by D0 solenoid pilot valve- allows for addition of modular valves to reduce shifting shock. Oil Immersed,

More information

Char-Lynn HP 30 Motor

Char-Lynn HP 30 Motor Char-Lynn HP 30 Motor Displacements cm 3 /r (in 3 /r) 344 (21.0) 400 (24.4) 434 (26.5) 480 (29.3) 677 (41.3) Engineered for Performance For the past 45 years, Char-Lynn has been recognized as the industry

More information

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications. Vickers Vane Pumps V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications Revised 6/95 560 Introduction Vickers offers the most complete line of hydraulic intravane

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

D03 FluiDyne Valves. ENGINEERING DATA

D03 FluiDyne Valves.   ENGINEERING DATA ENGINEERING D D3 FluiDyne Valves 4 Way, and 3 Postion Solenoid Operated Variety of Voltage and Spool Configurations Same Day Shipments 1 Month Warranty www.fluidynefp.com D3 FluiDyne Valves: 4 Way, and

More information

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated Vickers roportional Valves roportional Directional and hrottle Valves Solenoid Operated KDG4V-3S and KG4V-3S standard performance series K()DG4V-3 and K()G4V-3 high performance series ISO 4401-03 (NF D03)

More information

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications ilot Operated Directional s DIRECIONL CONROLS hese valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow. EIC-E-04-0 Specifications Model Numbers Maximum Flow L/min.

More information

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture. s Eaton Revised June, 1997 c Heavy Duty Hydrostatic Transmissions h i y d l ydraulics r a u u l c a i r s y d Models 33 through 76 Hydrostatic Transmissions We Manufacture Solutions H S o l u t i o n s

More information

Mounting and Assembly of Sandwich Bodies

Mounting and Assembly of Sandwich Bodies Mounting and ssembly of Sandwich odies Mounting of ISO 0 (CEO ) Sandwiches Many of Sun s ISO 0 (CEO ) sandwich bodies are designed for multi-functional use to permit maximum circuit flexibility. With the

More information

PRESSURE SWITCH 1PS / 1PF / 1PT

PRESSURE SWITCH 1PS / 1PF / 1PT RESSURE SWICH 1S / 1F / 1 Ref. No. 98 Release 7/2 1 Non adjustable differential type. Spring loaded sealed piston construction. Encapsulated design for protection against dust. Six pressure ranges available,

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-8; 7 l/min (185 USgpm) 35 bar (5 psi) DG5V-8; 7 l/min (185 USgpm) 35 bar (5 psi) NF D8, ISO-441-8, CEO 8 Introduction General Description he Size 8 Directiona

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NF D10, ISO-4401-10,

More information

Directional Controls

Directional Controls Vickers Directional Controls ilot Operated Directional Valves DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

EMechanically Operated Directional Valves

EMechanically Operated Directional Valves E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow

More information

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8 DIRCINL CNRLS Manually perated Directional s hese valves may be used to manually shift the spool position and change the direction of oil flow. IC--1005-0 Specifications Numbers DMG-01-C -10 DMG-01-D -10

More information

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct

More information

General specifications 3 5 Applications, features, and benefits 3 Specifications 4

General specifications 3 5 Applications, features, and benefits 3 Specifications 4 able of contents Description age No. General specifications 3 5 pplications, features, and benefits 3 Specifications 4 rinciples of operation 6 ost compensated circuit 6 re compensated circuit 6 Order

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are

More information

280 Series Stainless Steel Rotary Direction Control Valve For hydraulics in a harsh environment.

280 Series Stainless Steel Rotary Direction Control Valve For hydraulics in a harsh environment. 280 Series Stainless Steel Rotary Direction ontrol Valve For hydraulics in a harsh environment. he 280 Series is a high pressure, 316 stainless steel, hydraulic rotary direction control valve. It is the

More information

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled RELIEF VALVES Remote ontrol / Direct ype ilot Operated / Solenoid ontrolled Up to 5 Ma (3630 SI), 0 L /m in (06 U.S.GM) ub. E-00 Remote ontrol Relief Valves... age 3 his valve is used as a remote control

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides

More information

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

G SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) G SERIES SHOCKLESS TYPE "G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS

More information

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G VLVES POWER TRNSMISSION T E C H N I C L C T L O G Power transmission POCLIN HYDRULICS Methodology : This document is intended for manufacturers of machines that incorporate Poclain Hydraulics products.

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting Vickers Counterbalance Valve C Series ainfold ounting 315 ar SE Flange ounting 80-560 L/min Subplate ounting Table of Contents Counterbalance Valve General Description...2 Functional Symbols...2 odel Code...3

More information

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi)

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi) Vickers Servo Valves SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi) Released 1/94 653 Introduction Vickers SM4-30 servovalves can provide system closed loop control with

More information

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi)

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi) Vickers Servo Valves SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi) Released 12/93 651 Introduction Vickers SM4-10/12/15 servovalves can provide system closed loop

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -

More information

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models Model Codes P *** -(F)-(M) * *(F)(X) (*)-** -**-(C)-(G)-(L)- ** -**** 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 F V asic models = Fixed displacement type = Variable displacement type 2 Displacement PF and

More information

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN> DFE1 Ordering codes Description example : Diverter valve DFE1/3 18 ES - W 22-12VDC - SE - 1. 4. 5. 3. 5. 2. Valve is supplied painted as standard, with one coat of rimer black antirust paint II 5.

More information

Fixed Displacement Motor AA2FM (A2FM)

Fixed Displacement Motor AA2FM (A2FM) Fixed Displacement Motor 2FM (2FM) Series 6, for Open and Closed Circuits xial Piston, ent xis Design 5800 psi 6500 psi rueninghaus Hydromatik Sizes 5 1000 Nominal Pressure up to Peak Pressure up to (400

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such

More information

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP Electric roportional ressure Reducing Valves Series ER 03.ER - 0912 Electric proportional pressure reducing valves SERIES ER Index of content: Description and main features: age 3 echnical data: age 4

More information

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions s Eaton Revised April, 1996 c Directional Control Valves h i y d l ydraulics r a u u l c a i d r s Model 354, 15 GPM Directional Control Valves Solutions y We Manufacture H S o l u t i o n s Model 354

More information

Sandwich Bodies TECHNICAL PRODUCT INFORMATION

Sandwich Bodies TECHNICAL PRODUCT INFORMATION Sun offers sandwich and subplate mounted bodies for most of its cartridge functions. hese mounting configurations are complete circuit elements that mount under directional control valves. Similar to other

More information

Directional Controls

Directional Controls Vickers Directional Controls Pilot Operated Directional Control Valves DG5S4-10**-53 DG4S4-01-50 Air Gap Pilot Valve DG5S4-10**-80 DG4S4-01-60 Wet Armature Pilot Valve DG5S4-10** -90 DG4V-3S-60 Pilot Valve

More information

Model Model Model Model Back to Back. Medium Pressure Piston Pump Variable Displacement Closed Circuit

Model Model Model Model Back to Back. Medium Pressure Piston Pump Variable Displacement Closed Circuit Medium Pressure Piston Pump Variable Displacement Closed Circuit Model 76 2.3 cm 3 /r [.24 in 3 /r] 23.6 cm 3 /r [.44 in 3 /r] Model 736 4.6 cm 3 /r [2.48 in 3 /r] 49.2 cm 3 /r [3. in 3 /r] Model 724 4.6

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94 Vickers Servo Valves SM4-40 Servovalves Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94 654 Introduction Vickers SM4-40 servovalves can provide system closed loop control with

More information

Directional Control Valves

Directional Control Valves echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available

More information

DIRECT ACTING PRESSURE RELIEF VALVE Model : DPR

DIRECT ACTING PRESSURE RELIEF VALVE Model : DPR A olyhydron Group Company Description DIREC ACING RESSURE RELIEF VALVE Model : DR of 6 Ref. No. Release 05 / 24 Direct acting valve. Guided poppet design. Cushion arrangement for greater stability and

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US echnical Information General Description Series D1VW directional control

More information

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data Service Data Vickers Directional Valves Pilot Operated Directional Valves Eaton Hydraulics, Incorporated 14615 Lone Oak Road Eden Prairie, Minnesota 55344-2287 U.S.A. 5007.04/EN/0799/S DG5V - 8 - S/H -

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Catalog HY14-2500/US Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted

More information

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors: h y d r a u l i c s

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors: h y d r a u l i c s H y d r a u l i c s ydraulics Char-Lynn Hydraulic Motors: http://www.charlynn.com 00--0 h y d r a u l i c s General Purpose Motors We Manufacture No. - October 1 Solutions S o l u t i o n s Features Integrated

More information

XCEL80 Steering Control Units

XCEL80 Steering Control Units XCEL80 Steering Control Units XCEL80 Steering Unit SEPECIFICATION DATA Max. System Pressure 175 bar [2537 psi] Max. Back Pressure 21 bar [305 psi] Rated Flow 75 LPM [20 GPM] Input Torque Powered 1.3-2.4

More information

Motors & Pumps- Hydraulic Pumps, Motors & Power Units

Motors & Pumps- Hydraulic Pumps, Motors & Power Units - Hydraulic umps, Motors & ower Units - Rapid Response...12-1 12-6 Hydraulic umps - Check Valves...12-7 Hydraulic umps - ower Units...12-8 12-9 12MOTORS & UMS Hydraulic umps - Vane ump...12-10 Motors...12-11

More information

Modular valves DO5 (NG 10) 315 bar

Modular valves DO5 (NG 10) 315 bar Modular valves DO5 (N ) 315 bar 2 Modular valves DO5 (N ) 315 bar OSCH OSCH Modular valves DO5 (N ) 315 bar 3 roduct Range ressure relief valves age ressure reducing valves age 4 4 4 Check valves 4 16

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D05H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188) [ (4.188) 49,4 (1.94) /21,8 /.86) 174,7/172,3 (6.88/6.78) 332,9/33,5 (13.11/13.1) "M" is marked if metric port threads No marking if inch port threads AS-568-152 O-ring Vickers 45 65,3 (2.57) 13 (5.1 VMQ

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Catalog PowrFlowTM PVX Vane Pumps

Catalog PowrFlowTM PVX Vane Pumps Catalog PowrFlowTM PVX Vane Pumps Your source for vane pumps for the most demanding applications. What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane Pumps deliver

More information

Service Data Vickers. Directional Controls. Pilot Operated Directional Control Valves DG5S4-10**-*-*-53 I-3624-S. Revised 9/1/86

Service Data Vickers. Directional Controls. Pilot Operated Directional Control Valves DG5S4-10**-*-*-53 I-3624-S. Revised 9/1/86 Service Data Vickers Directional Controls Pilot Operated Directional Control Valves DG5S4-10**-*-*-53 Revised 9/1/86 I-3624-S Installation Table A DG5S4-10**-53 Does DG5S4-10**-E-53 Not DG5S4-10**-X-53

More information

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VAD05M-VMD05M AIR & LEVER OPERTAED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VAD05M-VMD05M AIR & LEVER OPERATED

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D0H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol Drive

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H05 5 gpm (19 L/min) nominal 8000 psi (560 bar) Sliding-spool H05 valves provide true four-way control in a simple

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation. Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Size 06 (D03) Q max 100 l/min (26.4 GPM) p max 250 bar (4600 PSI) RPE*-06 PRM*-06

Size 06 (D03) Q max 100 l/min (26.4 GPM) p max 250 bar (4600 PSI) RPE*-06 PRM*-06 Modular Load Sensing System MLS3-06 Size 06 (D03) Q max 00 l/min (26.4 GM) p max 250 bar (4600 SI) ossible Applications riority module riority module 2 ase module Section module REK distributors Section

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HM(HD)B 270 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3

More information

Solenoid Operated Directional Valve

Solenoid Operated Directional Valve Solenoid Operated irectional Valve G4V-3- esign 1. Product introduction and target applications G solenoid valves are used in hydraulic circuits to start, stop and direct flow. With electronics on board,

More information

Mobile Valves Proportional - Load Sensing

Mobile Valves Proportional - Load Sensing Mobile Valves Proportional - Load Sensing Model CML60 325 bar 60 L/min Up to 8 sections Eaton F(x) Compliant Table of Contents General Information... 3 Model Code Valve Section... 4 Valve Assembly... 5

More information

Product Tips and Features

Product Tips and Features 2.00.01 02/2002. Manifolds & Valve acks roduct ips and Features apping lates apping lates are sandwich adapters designed to provide a means to easily take pressure readings from the work ports. 1. Standard

More information

Housings and Miscellaneous Parts

Housings and Miscellaneous Parts Housings and Miscellaneous Parts Standard and Special Valve Housings, Orifice Disks, Orifice Sizing harts, Pilot Pistons, dapters, djustment Kits and Seal Kits ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1

More information

PowrFlow PVX Vane Pumps

PowrFlow PVX Vane Pumps PowrFlow PVX Vane Pumps POWRFLOW PVX VANE PUMPS YOUR SOURCE FOR VANE PUMPS FOR THE MOST DEMANDING APPLICATIONS What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane

More information

FIXED DISPLACEMENT VANE PUMPS

FIXED DISPLACEMENT VANE PUMPS FIXED DISPLACEMENT VANE PUMPS Single Vane Pumps Double Vane Pumps Thru-Drive Vane Pumps HS - HQ - VH - SERIES Working pressure: up to 210 bar Displacements: from 3 cc to 200 cc Pumps, cartridges and spare

More information

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY SERIES 0-1 - LIHT DUTY Hydraulic Motor RS RS (ll Series) For Light Duty pplications Overview RS Series motors are the most economical model in the White Drive Products product line, but are not low-tech.

More information