1 An Urgent Bulletin from CSA Group Ref No: I Lighting Products No. 73 Date: April 14, 2014 New Service available as of today Apply any time to have your products evaluated Announcing: Publication of Technical Information Letter (TIL) CSA B-81, Interim Certification Requirements for Self Ballasted Tubular LED (TLED) Type A Lamps Class No: , LAMPS - LED - Electrical Safety Only To purchase the Standard, visit us at Who is affected? Manufacturers of Self Ballasted Tubular LED (TLED) lamps. What do you do? 1. This publication provides for new certification services that do not affect your currently certified product designs. 2. Please contact CSA technical staff if you have questions or need information concerning this publication and how it applies to you. 3. If you would like to take advantage of the new certification services, initiate a certification project by contacting our Client Services Centre at Please supply appropriate supporting documentation* and we will inform you of the samples required. *which includes technical information, company name, address, factory locations and CSA file number or master contract number (if assigned), and any other relevant documentation. Should this T.I.L. not be incorporated into the standard within five (5) years, it may be withdrawn and certifications will be cancelled. Background and Rationale: The current edition of CSA Standard C includes a requirement specific to Canada that a TLED Type A device is not allowed unless the ballast or driver in combination with the LED lamp is approved for the application. This Informs announces publication of Technical Information Letter (TIL) No. B-81 which provides interim certification requirements of Tubular LED lamps (TLED) specified as Type A which are intended to replace fluorescent lamps and operate from the ballast that would be provided for the fluorescent lamp, without modifying the original lamp circuitry. These requirements will apply until they are incorporated into a future edition of CSA C22.2 No See TIL No. B-81 as Attachment 1 of this Informs. Introduction: For questions specific to your file or products contact your CSA Group technical staff associate. Go to and enter your Master Contract # and the class numbers associated with this Informs to view your certified products. For technical questions on this Informs Contact Avery Yearwood by phone , fax or avery.yearwood@csagroup.org Visit us at Click on "Contact Us" for the online phone listing of our Offices and Partners Page 1 of 6
2 ATTACHMENT 1 TECHNICAL INFORMATION LETTER CSA B-81 CSA Group, Certification and Testing Division Product Group: Lighting Date: April 14, 2014 Issued By: Approved By: Avery Yearwood John Jakob EQUIPMENT: ITEM: Self-ballasted Lamps Interim Certification Requirements for Self Ballasted Tubular LED (TLED) Type A Lamps REFERENCES: CSA C22.2 No Self-Ballasted Lamps and Lamp Adapters ANSI/ANSLG C Electric Lamps - Double-Capped Fluorescent Lamps - Dimensional and Electrical Characteristics NEMA ANSI/IEC C78.901:2005 Electric Lamps - Single Base Fluorescent Lamps - Dimensional and Electrical Characteristics NEMA ANSI C Reference Ballasts for Fluorescent Lamps Purpose This Technical Information Letter (TIL) has been prepared to provide interim certification requirements of Tubular LED (TLED) lamps specified as Type A in CSA C22.2 No A Type A TLED lamp is intended as a direct replacement for a fluorescent lamp and operate from the ballast that would be provided for the fluorescent lamp without modifying the lamp circuit. Background CSA Standard C22.2 No has a requirement specific to Canada that a TLED Type A device is not allowed unless the ballast or driver in combination with the LED lamp is approved for the application. Rationale Leading industry groups have expressed the need for specific testing and certification requirements for TLED Type A lamps which are directly interchangeable with fluorescent lamps without modifying the lamp circuitry of a luminaire installed in the field. Presently, there are no certification requirements for these products in Canada, as the standard does not specify how to evaluate and test TLED Type A lamps with the luminaire. Evaluation of the TLED Type A lamp by using a reference ballast as specified in NEMA ANSI C82.3:2002 provides the basis for acceptance of a TLED Type A lamp in this TIL. Page 2 of 6
3 Requirements 1 Scope 1.1 This Technical Information Letter (or TIL) shall be used in conjunction with CSA Standard C22.2 No , and contains construction, marking and test requirements for Type A Tubular Light-Emitting Diode (TLED) devices that have the general appearance, length and base types of a conventional fluorescent lamp, and are intended to directly replace a fluorescent lamp that complies with ANSI NEMA ANSLG C78.81 and NEMA C without additional modifications to the lamp, lampholder and ballast circuits. 1.2 The physical dimensions and base configurations of the Type A TLED lamps shall be in accordance with NEMA ANSI ANSLG C78.81 or NEMA ANSI C Clause SA1 of CSA C22.2 No applies, except as amended by this TIL. 2 Reference publications This Standard refers to the following publications, and where such reference is made, it shall be to the edition listed below, including all amendments published thereto. In addition to the reference publications listed in CSA C22.2 No , the following are applicable: CSA C22.2 No Self-Ballasted Lamps and Lamp Adapters ANSI/ANSLG C Electric Lamps - Double-Capped Fluorescent Lamps - Dimensional and Electrical Characteristics NEMA ANSI/IEC C78.901:2005 Electric Lamps - Single Base Fluorescent Lamps - Dimensional and Electrical Characteristics NEMA ANSI C82.3:2002 Reference Ballasts for Fluorescent Lamps 3 Definitions The definitions listed in CSA C22.2 No apply with the following addition: Reference Ballast for Fluorescent Lamps A special inductive-type ballast for fluorescent lamps which meets the essential design features and operating characteristics as given in NEMA ANSI C General Requirements The requirements of Clause 4 of CSA C22.2 No apply. 5 Construction 5.1 A TLED Type A lamp shall comply with the mechanical construction requirements of Clause SA5 of CSA C22.2 No Page 3 of 6
4 5.2 A TLED Type A lamp shall comply with the electrical construction requirements of Clause SA6 of CSA C22.2 No , except as amended by this TIL. 5.3 For the purposes of this TIL, Clause SA6.13.1a) of CSA C22.2 No is amended by the deletion of, In Canada, a Type A device is not allowed unless the ballast or driver in combination with the LED lamp is approved for the application. 5.4 A TLED Type A lamp shall comply with the test requirements of Clause 7 of this TIL. 6 Marking 6.1 In addition to the requirements of Clause SA10.2 of CSA C22.2 No , a TLED Type A lamp shall comply with the marking requirements of Clauses 6.2 to 6.3 of this TIL. 6.2 A TLED Type A lamp shall be marked with the identification of the lamp types and wattages it is intended to replace, as follows, verbatim in format S28-L1: a. DIRECT REPLACEMENT FOR LAMPS, ONLY, REMPLACEMENT POUR DES LAMPES DE TYPE, SEULEMENT, or b. DIRECT REPLACEMENT FOR THE FOLLOWING LAMPS ONLY, REMPLACEMENT POUR DES LAMPES DE TYPE SUIVANT SEULEMENT. Where the shall be replaced with the lamp type abbreviated as per NEMA ANSI C78.81 or NEMA ANSI C as applicable. Note: A 30W/36T8/PH-B is an example of an abbreviated lamp type, with reference to a 30-watt, 36-inch T8, preheat-start, bactericidal lamp type. 6.3 The following markings shall appear on the product and in the instruction manual, verbatim in format S28-L1 and S28-L2: a. The following caution in English and French: CAUTION - RISK OF FIRE. DO NOT INSTALL THIS LAMP IN A PRE-HEAT LUMINAIRE, and ATTENTION - RISQUE DE FEU. N'INSTALLEZ PAS CETTE LAMPE DANS UN APPAREIL D'ÉCLAIRAGE de PRÉCHAUFFAGE, or CAUTION - RISK OF FIRE. DO NOT INSTALL THIS LAMP IN LUMINAIRE EQUIPED WITH STARTER, and ATTENTION - RISQUE DE FEU. N'INSTALLEZ PAS CETTE LAMPE DANS UN APPAREIL D'ÉCLAIRAGE ÉQUIPÉ DE DÉMARREUR Note: A TLED Type A lamp shall not be used to replace a pre-heat type lamp, as the removal of the starter would be considered additional modification of the fluorescent lamp circuit and therfore not applicable to the Type A lamp definition. b. If a TLED Type A lamp is intended to operate with only an electronic ballast, the following statement, or equivalent: THIS LAMP ONLY OPERATES ON ELECTRONIC BALLAST. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN., and, CETTE LAMPE Page 4 of 6
5 OPERE SEULEMENT AVEC LE BALLAST ELECTRONIQUE. SI LA LAMPE NE S'ALLUME PAS QUAND L'APPAREIL D'ECLAIRAGE ACTIVE, ENLEVEZ LA LAMPE DE L'APPAREIL D'ECLAIRAGE ET CONTACTEZ LE FABRICANT DE LAMPE OU UN ELECTRICIEN QUALIFIE. ; and c. The following caution in English and French: CAUTION - IF THE LAMP OR LUMINAIRE EXIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT MANUFACTURER., and ATTENTION - SI LA LAMPE OU LE LUMINAIRE MONTRE DES SIGNES D'OPERATION INDESIRABLE (BRUIT, VIBRATION, CLIGNOTEMENT, ETC.), ALORS COUPER IMMÉDIATEMENT LE COURANT ET ENLÈVER LA LAMPE DE L'APPAREIL D'ÉCLAIRAGE ENTRER EN CONTACT AVEC LE FABRICANT. 7 Tests 7.1 The requirements of Clause 8.1 of CSA C22.2 No apply. 7.2 A TLED Type A device shall comply with the following tests in CSA C22.2 No : 1) Drop Impact Test of Clause SA8.8 2) Mould Stress Relief Conditioning of Clause SA 8.9 3) Humidity Conditioning of Clause SA 8.13, for a device intended for damp or wet locations 4) Water Spray Test of Clause 8.14, for a device intended for wet locations; and 5) Cold Impact Test of Clause 8.15, for a device intended for wet locations. 7.3 A TLED Type A lamp shall comply with the following tests of CSA C22.2 No using reference ballast as specified by NEMA ANSI C82.3. The voltage, current and power of the ballast shall be in accordance with NEMA ANSI/ANSLG C78.81 and NEMA ANSI C for the corresponding fluorescent lamp type. 1) Input Measurements of Clause SA8.2 2) Leakage Current of Clause 8.4 3) Temperature Test of Clause SA8.5 4) Dielectric Voltage-Withstand Test of Clause SA 8.6 5) Lamp Fault Conditions of Clause SA8.16 6) Risk of Electric Shock - Relamping of Clause SA ) Isolation of Lamp Pins of Clause SA8.20 8) Misapplication of Lamp Supply Connections of Clause SA8.21; and 9) LED Lamp and Driver Abnormal Condition Tests of Clause SA A TLED Type A lamp intended for use with only an electronic or magnetic ballast type shall be evaluated per Clause 7.3 with both a 25kHz and 60Hz reference ballast, unless the following occurs when the lamp is connected to the non-intended reference ballast tuned to the corresponding fluorescent lamp type: a) There is no illumination of its light source, arrays, or modules; b) The input current and power does not exceed 10% of the corresponding ratings of the fluorescent lamp intended to be replaced; and c) The TLED Type A lamp does not induce a DC component to the reference ballast or a cathode transformer exceeding 1% of the V rms value of the waveform during input measurements. 7.5 In addition to the compliance criteria in the tests specified in Clause 7.3, the following shall apply: Page 5 of 6
6 1) Input Measurements (Clause SA 8.2): a) The current, power or cathode current of a TLED Type A lamp shall be limited to the corresponding ratings of the fluorescent lamp intended to be replaced as specified in ANSI/ANSLG C78.81; and b) A TLED Type A lamp shall not induce a DC component to the reference ballast or a cathode transformer exceeding 1% of the V rms value of the waveform during input measurements. Note: If more severe test results can occur with a lower reference ballast input voltage, the test shall be performed with the voltage that produces the most severe results. 2) Dielectric Voltage Withstand Test (Clause SA 8.6) Same as in Clause SA8.6, except the value of V used in the test potential shall be equal to the open circuit voltage specified on the corresponding ballast. 3) Misapplication of Lamp Supply Connections (Clause SA8.21) Same as in Clause SA8.21, except a TLED Type A lamp does not require testing with 120, 277, or 347V ac at either lampholder. 4) LED Lamp and Driver Abnormal Condition Tests (Clause SA8.22): a) Same as stated above for Input Measurements 1) a), except the input limitations do not apply within the initial 5 seconds of the test; and b) Same as stated above for Input Measurements 1) b), except the waveform limitation does not apply within the initial 5 seconds of the test. Note: If more severe test results can occur with a lower reference ballast input voltage, the test shall be performed with the voltage that produces the most severe results. Page 6 of 6
An Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Elevator Equipment No. 24 Effective Date: January 1, 2019 Date: May 3, 2018 Apply Before September 1, 2018 Announcing: Withdrawing of TIL CSA D-11B and Publication of
More informationRef No: N Date: December 7, Fuseholder Assemblies No. 2. Call us today! See Attachment 1 for Effective Dates.
Ref No: N07-094 Date: December 7, 2007 Fuseholder Assemblies No. 2 See Attachment 1 for Effective Dates. Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272
More informationLUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed
Installation Guide LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Description The LUNERA VERTICAL E26 LED FLOODLIGHT is a line driven
More informationAn Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Occupational Health & Safety Products No. 115 (Replaces Occupational Health & Safety Products No. 92 Ref No. N16-002) Effective Date: July 1, 2019 Date: May 24, 2018 Apply
More informationBATTERY CHARGERS NO. 3
Date: January 10, 1992 BATTERY CHARGERS NO. 3 To: Subject: Manufacturers of Commercial/Industrial Battery Chargers Expansion of CSA Certification Service for Power Supplies to Include Low Voltage, Outdoor
More informationIMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationStandards Update Notice (SUN) Issued: June 6, 2017
Standard Information Standard Number: UL 153 Standard Name: Portable Electric Luminaires Standard Edition and Issue Date: 13 th Edition Dated March 3, 2014 Date of Revision: January 20, 2017 Date of Previous
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
More informationMOONRING 1.5 MOONRING 3
INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!
More informationINSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F
SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.
More informationINSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1
INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60923 Edition 3.1 2006-09 Edition 3:2005 consolidated with amendment 1:2006 Auxiliaries for lamps Ballasts for discharge lamps (excluding tubular fluorescent lamps) Performance
More informationSpecification sheet of T8 LED Tube
Specification sheet of T8 LED Tube Brief Introduction Special designed lockable 90-180 degree rotating end caps Lighting efficiency up to 100-110lm/W, Saves up to 70% Energy, Good a l t e rn at i ve to
More informationELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White
GE Lighting Immersion TM Elite LED Refrigerated Display Lighting End Mullion Lights for Vertical Cases Installation Guide ELV1abbccd-e Prefix: EL = Elite V = Vertical FD = French Door 1 = Generation Light
More informationRef No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2
Ref No: 95-013 Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2 To: Manufacturers of Industrial Control Equipment Subject: Publication of Technical Information Letter (T.I.L.) No D-21 on Interim
More informationAn Urgent Bulletin from CSA Group
Ref No: I15-014 Elevator Equipment No. 20 (Supersedes Elevator Equipment Certification Notice No. 1A, and Informs Elevator Equipment No 1B) Date: January 21, 2015 An Urgent Bulletin from CSA Group Existing
More informationIncentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )
Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Energy Trust offers cash incentives to help you implement approved energy efficient lighting measures. If
More informationINSTALLATION INSTRUCTIONS
INDIGO-CLEAN TECHNOLOGY RETROFIT KIT INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFETY INFORMATION Risk of shock. Disconnect power before installation. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L
More informationMODELS. 2 & 4 Low Profile Linears
INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-2182-99 Rev D December, 2016 MODELS 2 & 4 Low Profile Linears These instructions contain important safety information,
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationUHC-202 Hardware Guide
R Description The UHC202 is a fullyintegrated VAV terminal unit controller, complete with differential pressure sensor and integral Belimo LM24M zone damper motor. The UHC202 is designed for singlebox
More informationTECTONIC LED CORP. ISO
TECTONIC TECTONIC LED CORP. ISO 9001:2000 Products RoHs Compliance Instruction Menu Retrofit:LED Tube Lamps SECTION 1 - General Information Kit components: 1-LED Tube, 1-Label and 1-Set of Instructions
More informationLED microwave sensor T8 tube light
LED microwave sensor T8 tube light Product Feature Microwave sensor LED T8 offers a driver and radar sensor intergrated technology. The new technology helps the LED tube save more energy. LED tube will
More informationMODELS 2 & 4 Top Conduit Linears
INSTALLATION AND MAINTENANCE MANUAL SAFESITE AND DUROSITE LED LINEAR FIXTURE Document No: 9100-127-1885-99 Rev E December, 2016 MODELS 2 & 4 Top Conduit Linears These instructions contain important safety
More informationUL and CSA Requirement for LED Tubes and LED Bulbs. UL Safety for LED Tubes and Bulbs
UL and CSA Requirement for LED Tubes and LED Bulbs UL Safety for LED Tubes and Bulbs Version and Validation UL effective date: December 4, 2012 UL transition period to: December 4, 2015 2 Enclosure Requirement
More informationINSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.
Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.
More informationDistribution Restriction Statement Approved for public release; distribution is unlimited.
CEMP-ET Engineer Technical Letter 1110-3-441 Department of the Army U.S. Army Corps of Engineers Washington, DC 20314-1000 Engineering and Design ELECTRONIC BALLASTS FOR FLUORESCENT LIGHTING FIXTURES ETL
More informationCaptivate Illuminated Mirror Light
ENGLISH WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY FRANÇAIS MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL
More informationSolid State T8 tube is the smart alternative to a
Solid State T8 tube Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, government buildings, and multi-unit residences L Prize Winner Solid State T8 tube Direct Replacement
More informationAmendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts
Revision 1 Date: 28/01/2016 Amendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts In the said schedule, (i) in paragraph 7, for sub-paragraph (i) the following shall be substituted,
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Champ Fluorescent Luminaires DMVFB Auxiliary Series - 52, 64, & 84 Watt Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1713 IMPORTANT SAFEGUARDS READ AND FOLLOW
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-28543-2 Edition 2.1 and IEC corr. 1 IEC 62271-100:2012 Edition 2.1 and corr. 1 SOUTH AFRICAN NATIONAL STANDARD High-voltage switchgear and controlgear This national standard is the identical
More informationCSD Series Current Devices Split Core
CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More informationProduct Installation Instruction LED Tube Lamp Retrofit Kits
Regular T8 internal driver single end Product Installation Instruction LED Tube Lamp Retrofit Kits 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard T8
More informationMODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions
INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-1622-00 Rev E December, 2016 MODELS SafeSite LED Linear, Class I Div. 1 347-480V, 2 & 4 Versions All the above Models
More informationLAL SERIES LED LUMINAIRE
INSTALLATION, OPERATION & MAINTENANCE DATA SHEET LAL SERIES LED LUMINAIRE CAUTION: LAL SERIES LED LUMINAIRE Before installing, make sure you are compliant with area classifications, failure to do so may
More informationANSI_ANSLG C Revision of ANSI_ANSLG C American National Standard. for Electric Lamps High-Pressure Sodium Lamps
American National Standard for Electric Lamps High-Pressure Sodium Lamps American National Standard Approved: December 16, 2009 Secretariat: American National Standard Lighting Group for electric lamps:
More informationTechnical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)
Ergon Energy Corporation Limited Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear ETS12-01-03 Specification ETS12-01-03 Ver 3 Contents 1. Purpose and Scope...
More informationSafety information. English
English Safety information To prevent injury to yourself and others or damage to your device, read the safety information about your device before using the device Samsung cannot be held responsible for
More informationInstruction/Installation Manual
Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1 SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only
More informationIEC B:1993,
IEC 60383-1 Ed. 4.0 B:1993, Insulators For Overhead Lines With A Nominal Voltage Above 1000 V - Part 1: Ceramic Or Glass Insulator Units For A.c.... Test Methods And Acceptance Criteria By IEC TC/SC 36B
More informationTetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide
Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn
More informationDEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016
Trade and Industry, Department of/ Handel en Nywerheid, Departement van 438 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Earth Leakage Protection
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationICN2S40N35I Ele Ballast (2) F40T V
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN2S40N35I Ele Ballast (2) F40T12 120-277V Philips Advance Catalog Number Manufacturer Description Weight per unit Product
More informationTHE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY. PARTIAL STREET LIGHTING SERVICE RATE 117 Page 1 of 5
Page 1 of 5 AVAILABLE for municipal street and highway lighting for dusk to dawn or midnight lighting services as provided below within the Company service area where all street lighting equipment within
More informationIndicativul și titlul standardului doc.
N/o Data votării Comitetul Tehnic Indicativul și titlul standardului Tipul doc. Pro (P) Contra (C) Votul Abținere (A) Total voturi Votul final (P, C, A) Comentarii Da Nu 1. 2012 04 12 TC 88 IEC 61400 23
More informationCSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440
CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440 APPLICATION SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CSR compact fused interlocked ARKTITE
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-33678-3 SANS 1239:2004 Any reference to SABS 1239 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 November 2002) SOUTH AFRICAN NATIONAL STANDARD Plugs, socket-outlets
More informationLED 2/3/4ft T8 Tube 120V
E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent
More informationElectric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT
Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation
More informationE/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1
30 August 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions for
More informationINSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.
INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-26065-1 Edition 1 EN 12281:2002 Edition 2 SOUTH AFRICAN NATIONAL STANDARD Printing and business paper Requirements for copy paper for dry toner imaging processes This national standard is
More informationTechnical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications ETS12-01-04 Specification ETS12-01-04 Ver 3 Contents 1. Purpose and Scope...
More informationTechnical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear ETS12-01-02 Specification ETS12-01-02 Ver 3 Contents 1. Purpose
More informationAmerican National Standard for Lighting Equipment Voltage Surge Requirements
American National Standard for Lighting Equipment Voltage Surge Requirements Secretariat: National Electrical Manufacturers Association Approved: December 21, 2017 American National Standards Institute,
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 0-626-18502-5 SANS 60335-2-76:2006 IEC 60335-2-76:2006 SOUTH AFRICAN NATIONAL STANDARD Household and similar electrical appliances Safety Part 2-76: Particular requirements for electric fence energizers
More informationSubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M
SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Type A design complies with AS/NZS 60598.2.1:2014/
More informationHOW IS LIGHT PRODUCED
HOW IS LIGHT PRODUCED The fluorescent lamp produces light by the passage of an electric current flowing through a vapor of mercury. 1.Electron emitted from electrode collides with mercury atom. 2.Impact
More informationInstallation & User Instructions
Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.
More informationMAXLITE RKT LED Retrofit Kit
MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent
More informationSpun Bay Installation Standard Version (non dimmable), Hook Mount
Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn
More informationNon-illuminated Push Buttons
Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,
More informationINSTALLATION GUIDE Works in double and single ended wiring.
ISTAATIO GUIDE Works in double and single ended wiring. -1- Safety Precautions For your and others safety, please read the precaution carefully before installation: (1). Product should be installed by
More informationOkSolar LED Outdoor Luminaires
OkSolar 488500 LED Outdoor Luminaires 1.0 PURPOSE The purpose of this specification is to provide the minimum performance requirements for the LED Outdoor Luminaire Fixture. This specification refers to
More informationProposal for amendments to Regulations Nos. 19, 48 and 98.
Submitted by the expert from Germany Informal document. GRE-68-15 (68th GRE, 26 29 March 2012, agenda item 5(i)) Proposal for amendments to Regulations Nos. 19, 48 and 98. Submitted by the expert from
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationCity of Ottawa Street Lighting. HID Shoebox Style Luminaire
TITLE: Engineering Specification RECOMMENDED: S. Edey NO: 1 REV: APPROVED: D. O Keefe. LLS0002 OF REV. DATE: 2010-01-07 9 4 City of Ottawa Street Lighting HID Shoebox Style Luminaire For City of Ottawa
More informationTechnical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationINTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY
INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES 10-100 KILOWATTS IN THE STATE OF NEW JERSEY January 1, 2005 Rockland Electric Company 390 West Route 59 Spring Valley,
More informationELECTROTECHNICAL Letter of Authority (LOA) ADMINISTRATION PROCEDURE
ELECTROTECHNICAL Letter of Authority (LOA) ADMINISTRATION PROCEDURE LETTER OF AUTHORITY (LOA) PROCESS 1. Background: Government Notice R 89 dated 6 February 2009 published in Government Gazette 31844 introduced
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 1179-2 First edition 2007-08-15 Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 2: Heavy-duty
More informationFLUORESCENT INDUCTION
FLUORESCENT INDUCTION Electrodeless Lamp OPENING NEW FRONTIERS FOR LIGHTING IT IS IMPOSSIBLE TO IMAGINE MODERN LIFE WITHOUT ELECTRIC LIGHTING. WITH THE WIDE AVAILABILITY AND AFFORDABILITY OF TODAY S LIGHTING,
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationGB/T / IEC :2007
Translated English of Chinese Standard: GB/T16935.1-2008 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.120 K 30 GB/T 16935.1-2008 / IEC
More informationINSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit
INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS
More information(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)
A. CHECKLIST (4 each AA Batteries Included) FOR DOOR AND FRAME PREPARATION INSTRUCTIONS, SEE APPENDIX A OR GO TO PROXESS.COM Parts List: Each Proxess C-Series lockset includes Exterior lock assembly (include
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 1179-3 First edition 2007-08-15 Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 3: Light-duty
More informationT5 Watt-Miser Linear Fluorescent lamps
GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 14W, 21W, 28W, 35W T5 Watt-Miser High Output 24W, 39W, 49W, 54W, 80W Product information T5 Watt-Miser lamps
More informationSpecification Grade Contemporary Wall Mount/Technical Installation Data
AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationMANUFACTURED IN THE UK
The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Trojan leads vandal-resistant IP65 technology. With a hinged
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60470 Second edition 1999-10 High-voltage alternating current contactors and contactor-based motor-starters Contacteurs pour courants alternatifs haute tension et démarreurs
More informationGuideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society
Guideline No.: E-04(201510) E-04 GENERATORS Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection
More informationPERFORMANCE SPECIFICATION SHEET BATTERY, STORAGE, AIRCRAFT, MAINTENANCE-FREE, 24-VOLT, 1.5-AMPERE-HOUR
METRIC MIL-PRF-8565/6A (AS) 25 June 2001 SUPERSEDING DOD-B-8565/6(AS) 26 June 1987 PERFORMANCE SPECIFICATION SHEET BATTERY, STORAGE, AIRCRAFT, MAINTENANCE-FREE, 24-VOLT, 1.5-AMPERE-HOUR This specification
More informationLUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS consist
More informationGuideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society
Guideline No.: E-04(201610) E-04 GENERATORS Issued date: October 28,2016 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains technical requirements, inspection
More informationPrüffeld der Schaltwerke
Report No.: 16-043-MS Sheet: 2 Notes 1. The testing station of the Siemens switchgear factory (Prüffeld der Schaltwerke),, Berlin, has been approved by the DAkkS (German accreditation body) for rendering
More informationSmart Look Series Meter
File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement
More informationTechnical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders
Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...
More informationLUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More informationdiode led FLUID VIEW 12V LED Tape Light 12VDC FEATURES Soft illumination Accent or ambient lighting Closet-safe Largest CCT selection QUICK SPECS
diode led a division of elemental LED FLUID VIEW 12V LED Tape Light SPECIFICATION SHEET ACTUAL SIZE FLUID VIEW LED Tape Light is our most popular LED lighting solution and is an excellent accent indoor
More informationQUICKTRONIC ICE Universal Voltage Systems
QUICKTRONIC ICE Universal Voltage Systems Electrodeless Fluorescent Systems Lamp / Ballast Guide lamp: ICE 40W QT1x40ICE/UNV lamp: ICE 70W QT1x100ICE/UNV lamps: ICE 100W QT1x100ICE/UNV QT1x150ICE/UNV lamp:
More informationdiode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS
diode led a division of elemental LED BLAZE 12V LED Tape Light SPECIFICATION SHEET ACTUAL SIZE Our most popular tape light in our portfolio, BLAZE 12V LED Tape Light is perfect for accent and task lighting
More informationThis standard covers the requirements of lighting chains. This standard covers only the safety requirements.
FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the
More informationOptanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:
Optanium High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps P R O D U C T O V E R V I E W : Advance expands a new family of Smart Solutions for T8 lighting systems Optanium.
More information