Smart Look Series Meter
|
|
- Paul Richards
- 5 years ago
- Views:
Transcription
1 File No. E Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement of AC & DC ammeters, voltmeter & frequency meters utilizing a high torque pivot and jewel movement and elapsed time meters. Special Features Surface mounting. Near linear scale. Glass lled polycarbonate housing (UL 94 V-0). Compact case sizes.
2 ' Smart Look Series Meter Application The smart look range of analog panel meters offers accurate measurement and indication of most electrical 1/2 & electronics parameters in industry standard 2 " 1/2, 3 " case sizes. A range of short scale panel meters that comply with Internationally recognised specifications. Their rugged design will suit demanding environmental applications. Functional Areas Switchgear Distribution systems Control panels Generator sets Energy managment Building managment Utility power managment Process control Motor monitoring Features 1/2 " 1/2 " Two case sizes available : 2, 3 inches Dust and water jet protected to IP54 (NEMA 4) Withstands high levels of shock, vibration, dirt and humidity. UL approved. Instruments comply with EN and meets IEC414 Dielectric Test. Complies with international standards : IEC51 (EN60051) or ANSI-C39.1 Benefits AC moving iron and moving coil mechanisms. ANSI standard case sizes. Elapsed time movement mechanism. Operation Moving Coil Meter Frequency Meter These meters offers a centre cored, self shielding moving coil Frequency meters use a 90 µ A movement driven by an movements using pivots, hairspring and spring jewels. Variations EMC hard frequency conversion circuit. in movement are limited by design. All DC voltmeters are 1000 Dials, Pointers and Scales ohms per volt, moving coil rectified products run at 900 ohms per volt. Milivolt meter use the 5 miliamps/50mv resistance. Standard dials are matt white black printed scales and a tubular knife- edge black are balanced within 1% of scale length and Moving Iron Meter feature a highly repeatable flattened are scale shape, ensuring This clapper type repulsion design utilizes a pivot, hairspring and consistently accurate measurement reading. Dials are jewel movement. The bottom jewel is oil filled to provide damping interchangable between the contendor range of products using while th top is spring for resilience.all voltmeters are manufactured the same input within the published specification of the meter. Options for non standard customer specific dials are available with internal voltage dropper resistor. upon request. Page 1 of 7 Version No. : APMSL/2016/08
3 Smart Look Series Meter Technical Specifications Applicable Standards Terminal bolts/leads DIN 46200/46282 Safety requirements and protective measures for Electrical indicating. instruments and their accessories Performance speci cations for direct acting indicating analogue electrical measuring instruments and their accessories IEC 529, IEC IS 1248 IEC 51 ANSI C UL Compatibility UL 94 V-0 Mechanical Data Case details Case material Front window Colour of case Position of use Panel xing Moulded case suitable for mounting in Control / switchgear panels Machinery consoles. Polycarbonate, ame retardant and drip proof as per UL 94 V-0. Polycarbonate (transparent) Black Vertical Fixing Stud Comply with following European directives 2004 / 108 / EC (EMC directive ), 2006 / 95/EC ( low voltage directive ) & amendment 93/68/EEC, For CE Marking. Panel thickness < 10 mm Pointer Pointer de ection 90 Scale characteristics Scale division Scale and Pointer Spear o (A) Near Linear above 10% of nominal full Scale value for moving iron (B) Linear scale for moving coil, frequency, moving coil with rectifier Coarse - ne Voltmeters and Ammeters & Frequency meters Fixing Reference Conditions Accuracy Terminals Terminal UNF, Washer UNF Surface mounting with 2 studs/3 studs /4 studs by 4-40 UNC studs. According to IEC 51/DIN EN Scale length mm mm DC Ammeters & Voltmeters Frequency Meters Ambient temperature 23 C ± 2 C 1.5% 0 to 100% of full scale deflection AC Ammeters & Voltmeters Moving iron: 1.5% 10 to 100% of full scale deflection Moving coil: 1.5% 0 to 100% of full scale deflection 0.5% of end scale value Position of use Nominal position ±1 Nominal Range of use Ambient Temperature C Position of use Vertical ± 5 Input Waveform Frequency Rated value of measured quantity sine wave, distortion factor < 5% 45-65Hz Other Conditions IEC 51/DIN EN Frequency External Magnetic Field FN ± 10% At 0.4 ka/m Page 2 of 7 Version No. : APMSL/2016/08
4 Smart Look Series Meter Electrical Data Elapsed Time Meter and Frequency Meter Voltage 100/125V 200/250V Frequency Meters B urden Accuracy Class 1.5 Options Front Window Color of Case Case 45 or 55Hz 55 or 65Hz 45 or 65 Hz 4 VA Maximum Moving Iron A.C. Ammeters & Voltmeters Rating Ammeters Voltmeters Overload Ammeters Voltmeters B urden Ammeters Voltmeters 1 to 30 A 10V to 600V Moving Coil D.C. Ammeters & Voltmeters Accuracy Class 1.5 Rating Ammeters Voltmeters x 1.2 for 2 Hours x 10 for 5 Sec x 1.2 for 2 Hours x 2 for 5 Sec 0.5 VA 4.5 VA 100mA to 30A 50mV to 600V Polycarbonate (Transparent) Black Environmental Conditions Climatic Suitability Climate category II as per IEC (climatic class 3 according to VDE/VDI 3540) Operating Temperature 0 C C Storage temperature Relative humidity Shock resistance - 20 C C 25% to 80% nominal range of use 15 g. for pulse duration 11ms Vibration resistance ANSI C39.1 cl Standard Measuring Ranges DC moving coil Ammeters (PQ) Safety Precautions o o 1) Instruments with damaged window or glasses must be disconnected from the mains. 2) Adequate safety clearance must be maintained to control panel fasteners and to sheet metal housing. If non - insulated connector wires are used. 3) Instruments to be used in grounded panel. o o 50 ma to 50 A DC moving coil Voltmeters (PQ) 50 mv to 600 V AC moving coil Ammeters (VQ) AC moving coil Voltmeters (VQ) AC moving iron Ammeters (EQ) AC moving coil Voltmeters (EQ) Frequency Meters Elapsed Time Meters (ETM) 1 ma to 100 ma 6 V to 600 V 100 ma to 30 A 6 V to 600 V Hz, Hz, Hz, Hz 110/130 V, 60 Hz Blank dial Special markings Division dials Color markings/bands Over range (Moving Iron Ammter) Dial With initial and end values marked Numbering/Lettering Basic divisions without numbering Red or green Two, three and ve times over range Page 3 of 7 Version No. : APMSL/2016/08
5 Smart Look Series Alpha Meter 70 Specifications A.C. AMMETERS - TRUE RMS READING (EQ) Rating 5A 10A 15A 20A 30A 60A 1A 5A Scale 0-5A 0-10A 0-15A 0-20A 0-30A 0-60A Transformer Rated Transformer Rated A.C. VOLTMETERS - TRUE RMS READING (EQ) Rating 150V 300V 600V 750V 0-1 ma 0-5 ma 0-10 ma 0-20 ma 0-50 ma ma ma ma ma 0-1A 0-2A 0-4A 0-5A 0-6A 0-10A 0-20A 0-30A D.C. AMMETERS (PQ) Rating 0-150V 0-300V 0-600V Transformer Rated 0-5 ma 0-10 ma 0-20 ma 0-50 ma ma ma ma ma 0-1A 0-2A 0-4A 0-5A 0-6A 0-10A 0-20A 0-30A MILLIAMMETERS - SUPRESSED ZERO (PQ) Rating 4-20 ma Scale Scale Scale Rating 0-50 mv mv 0-15 V 0-30 V 0-50 V V V V D.C. Voltmeters (PQ) FREQUENCY METERS, 120V (Self Contained) Rating 50 Hz 55 Hz 60 Hz 400 Hz 110/130 V, 50 Hz 200/250 V, 50 Hz 480 V, 50 Hz 110/130 V, 60 Hz 200/250 V, 60 Hz 480 V, 60 Hz Scale 0-15 V 0-30 V 0-50 V V V V Scale Hz Hz Hz Hz ELAPSED TIME METERS ( HOURS) (ETM) 1 ma 1.5 ma 10 ma 15 ma 20 ma 40 ma 60 ma 100 ma AC Moving Coil Ammeter (VQ) Rating AC Moving Coil Voltmeter (VQ) Rating Scale ma 0-10 ma 0-15 ma 0-20 ma 0-40 ma 0-60 ma ma Scale 100 V 150 V 250 V 400 V 500 V 600 V V V V V V V Page 4 of 7 Version No. : APMSL/2016/08
6 Smart Look Series Alpha Meter 70 Electrical Connections DC Amps - Self Contained DC Amps - For use with external shunt DC Volts AC Amps - Self Contained AC Amps - For use with Current Transformer AC Volts Frequency Meter Elapsed Time Meter Page 5 of 7 Version No. : APMSL/2016/08
7 Smart Look Series Meter Application Dimensions UNF 4-40 UNC PANEL CUT-OUT :- Specify the No. of fixing studs while ordering J Q Q J K L J N P Q Q M M Q Q STUD POSITION FOR TWO FIXING STUDS STUD POSITION FOR THREE FIXING STUDS STUD POSITION FOR FOUR FIXING STUDS 2 ½ mm Inch 3 ½ mm Inch A B C D E F G H J K L M N P Q Page 6 of 7 Version No. : APMSL/2016/08
8 Smart Look Series Meter For more details and product codes, please contact our local of ce Sifam Tinsley Instrumentation Inc. 3105, Creekside Village Drive, Suite No. 801, Kennesaw, Georgia (USA) Id : psk@sifamtinsley.com Web : Contact No. : Sifam Tinsley Instrumentation Ltd Unit 1 Warner Drive, Springwood Industrial Estate Braintree, Essex, UK, CM72YW sales@sifamtinsley.com Web: Contact: +44(0) Page 7 of 7 Version No. : APMSL/2016/08
9 Sifam Tinsley Instrume ntation Inc. Smart Look Series Coding Table Sifam Tinsley Instrumentation Inc. 3105, Creekside Village Drive, Suite No. 801, Kennesaw, GA (USA) Contact : psk@sifamtinsley.com Powered By Tec hn ology... Driven By Ser vice...
10 Product Code VQ2L- X XX X X X X Input type for VQ2L Current Meter I Voltage Meter V Measuring range for VQ2L 200uA uA uA 03 1mA 04 20mA mA 08 50V 2M 100V 2N 150V 2P 300V 2Q 500V 2R x xx xxx (For voltmeter :30-50V possible in 2.5%) (For ammeter : All ua ranges possible in 2.5%) Zero position for VQ2L Left Zero L Accuracy Class for VQ2L Class Class Class Type of Dial for VQ2L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for VQ2L Black Background B White background W NA X No. of stud for VQ2L Two stud 2 Three stud 3 Four stud 4 Customer Code for VQ2L Sifam Tinsley ST 000
11 Product Code VQ3L- X XX X X X X Input type for VQ3L Current Meter I Voltage Meter V Measuring range for VQ3L 200uA uA uA 03 1mA 04 20mA mA 08 50V 2M 100V 2N 150V 2P 300V 2Q 500V 2R x xx xxx (For voltmeter :30-50V possible in 2.5%) (For ammeter : All ua ranges possible in 2.5%) Zero position for VQ3L Left Zero L Accuracy Class for VQ3L Class Class Class Type of Dial for VQ3L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for VQ3L Black Background B White background W NA X No. of stud for VQ3L Two stud 2 Three stud 3 Four stud 4 Customer Code for VQ3L Sifam Tinsley ST 000
12 Product Code PQ2L- X XX X X X X Input type for PQ2L Current Meter I Voltage Meter V Measuring range for PQ2L 200uA uA uA 03 1mA 04 20mA mA mA 09 1A 10 3A 12 5A 13 10A 14 50mV 2A 100mV 2D 200mV 2E 1.5V 2F 10V 2J 100V 2N 150V 2P 300V 2Q 500V 2R x xx xxx Zero position for PQ2L Left Zero L Right Zero R Center Zero C Suppressed Zero S Shifted zero H Accuracy Class for PQ2L Class Class Class Type of Dial for PQ2L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for PQ2L Black Background B White background W NA X No. of stud for PQ2L Two stud 2 Three stud 3 Four stud 4 Customer Code for PQ2L Sifam Tinsley ST 000
13 Product Code PQ3L- X XX X X X X Input type for PQ3L Current Meter I Voltage Meter V Measuring range for PQ3L 200uA 500uA uA 03 1mA 04 20mA mA mA 09 1A 10 3A 12 5A 13 10A 14 30A 16 50mV 2A 100mV 2D 200mV 2E 1.5V 2F 10V 2J 100V 2N 150V 2P 300V 2Q 500V 2R x xx xxx Zero position for PQ3L Left Zero L Right Zero R Center Zero C Suppressed Zero S Shifted zero H Accuracy Class for PQ3L Class Class Class Type of Dial for PQ3L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for PQ3L Black Background B White background W NA X No. of stud for PQ3L Two stud 2 Three stud 3 Four stud 4 Customer Code for PQ3L Sifam Tinsley ST 000
14 Product Code EQ2L- X XX X X X X Input type for EQ2L Current Meter I Voltage Meter V Measuring range for EQ2L 1Amps 1.25Amps Amps 03 3Amps 04 5Amps 05 8Amps 07 12Amps 09 15Amps 10 20Amps 11 25Amps 13 30Amps V 2A 150 V 2B 250 V 2D 300V 2E 500V 2F 600V 2G 750V 2H 30V 2J 100 V 2K 165V 2L Suppression for EQ2L X1 1 X2 2 X3 3 X4 4 X5 5 X6 NA 6 X x xx xxx Accuracy Class for EQ2L Class Class Class Type of Dial for EQ2L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for EQ2L Black Background B White background W NA X No. of stud for EQ2L Two stud 2 Three stud 3 Four stud 4 Customer Code for EQ2L Sifam Tinsley ST 000
15 Product Code EQ3L- X XX X X X X Input type for EQ3L Current Meter I Voltage Meter V Measuring range for EQ3L 1Amps 1.25Amps Amps 03 3Amps 04 5Amps 05 8Amps 07 12Amps 09 15Amps 10 20Amps 11 25Amps 13 30Amps V 2A 150 V 2B 250 V 2D 300V 2E 500V 2F 600V 2G 750V 2H 30V 2J 100 V 2K 165V 2L Suppression for EQ3L X1 1 X2 2 X3 3 X4 4 X5 5 X6 NA 6 X x xx xxx Accuracy Class for EQ3L Class Class Class Type of Dial for EQ3L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Without Dial X Blank Scale B Background for EQ3L Black Background B White background W NA X No. of stud for EQ3L Two stud 2 Three stud 3 Four stud 4 Customer Code for EQ3L Sifam Tinsley ST 000
16 Product Code ZQ2L- XX XX X X X X XXX XX Frequency for ZQ2L Hz Hz Hz Hz 38 Input Voltage for ZQ2L V V V V V V 06 Accuracy for ZQ2L Class Class Type of Dial for ZQ2L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Background for ZQ2L Black Background B White background W Stud for ZQ2L Two stud 2 Three Stud 3 Four stud Customer Code for ZQ2L Sifam Tinsley ST
17 Product Code ZQ3L- XX XX X X X X XXX XX Frequency for ZQ3L Hz Hz Hz Hz 38 Input Voltage for ZQ3L V V V V V V 06 Accuracy for ZQ3L Class Class Type of Dial for ZQ3L Standard Aluminum A Aluminum with Colour mark R Aluminium with colour bands C Background for ZQ3L Black Background B White background W Stud for ZQ3L Two stud 2 Three Stud 3 Four stud Customer Code for ZQ3L Sifam Tinsley ST
18 Product Code ET2L- XX X X X X X X XX X X X Input type for ET2L V V V 07 Frequency for ET2L 50Hz 5 100Hz 6 Suppression for ET2L NA X Accuracy for ET2L NA X X Type of dial for ET2L Standard Aluminum A Background for ET2L White background W NA No. of Stud. ET2L Three stud 3 Four stud 4 Customer code for ET2L Sifam Tinsley ST 0 0 0
19 Product Code ET3L- XX X X X X X X XX X X X Input type for ET3L V V V 07 Frequency for ET3L 50Hz 5 100Hz 6 Suppression for ET3L NA X Accuracy for ET3L NA X X Type of dial for ET3L Standard Aluminum A Background for ET3L White background W NA No. of Stud. ET3L Three stud 3 Four stud 4 Customer code for ET3L Sifam Tinsley ST 0 0 0
212, 312 & 412 Vista Series Analog Panel Meter
212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as
More informationTechnical Data Sheet Sigma Series DE Meter
Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency
More information212, 312 & 412 Vista Series Analog Panel Meter
C R LISTED File No. E471457 Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as
More informationTechnical Data Sheet Sigma Series DS Meter
Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments
More informationTechnical Data Sheet Sigma Series DG Meter
Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear
More informationSIGMA SERIES DE METER
SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationJewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS
Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:
More informationSmart Look Series Meter
File N. E471457 Technical Data Sheet Smart Lk Series Meter 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are hused in a mulded plycarbnate cases which are suitable fr the measurement f
More informationPOWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS
POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationPLATINUM SERIES SWITCHBOARD METERS
PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders
More informationBIG-VUE Series Meter
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet BIG-VUE Series Meter File N. E471457 LAC DU FLAMBEAU,WI LAC DU FLAMBEAU,WI 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are
More informationM Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96
Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide
More informationM Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS
Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic
More informationCentury Style Analog Panel Meters
UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &
More informationDIN Panel Meters Long Scale
DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationData Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement
Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144 Data Sheet Analogue Meters with Moving - Iron Movement Tel. +91 253 22216, 22222 Fax +91 253 235164 E-mail India - marketing@rishabh.co.in
More informationAC Wattmeters and VArmeters
AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to
More informationWide-Vue Analog Panel Meters
UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel
More informationWide-Vue Analog Panel Meters
UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel
More informationAnalogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy
Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard
More informationCrompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION
Crompton AC Overload Ammeters X6 Overload Scaling for Motor Start Duty True RMS Reading, Self Contained 50/60Hz 3 1 /2", 3 /16 DIN & 1 /4 DIN sizes Fiesta Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ Accuracy
More informationYOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant
YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant Elapsed Time Meters Devices will match the frequency of AC power systems. Six-digit counters record hours, tenths of hours, minutes
More informationStandard Program Technical Description
Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable Scales Meter s scale
More informationROTARY CAM SWITCHES CAM SERIES. User Manual - Issue 1.1
Cam Series www.sifamtinsley.co.uk NEW PRODUCTS Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters
More informationPrice List Effective from :
List Effective from :- 01-04-2018 INDICATING MOVING IRON, MOVING COIL VOLTMETER & AMMETER ME BRAND Moving Iron Instruments are generally used for measuring A.C. Voltage and currents. These are Repulsion
More informationPortable Instruments. Bulletin 2000-E
Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments
More informationLED Digital Analog Combination
Crompton Instruments model 007-DI features a combination of the traditional 250 4 1 2" switchboard indicator with the trend indication plus the benefits of wide angle LED visibility. This rugged shock
More informationPanel Meters and Accessories Digital Panel Meter
Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor
More informationProduct Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.
Product Information www.vdo.com Viewline Temperature gauges Description Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature. Features _ Integrated Warning LED. _ Changeable Frontbezels.
More informationPressure Transmitters
Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationField IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage
Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use
More informationSECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.
88 Metering Solution-Oriented Metering Keeping track of onboard systems is critical to safety and peace of mind. Running low on fuel or not knowing about a failing battery can lead to dangerous situations.
More informationPRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT
Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationSquare Shape Instrument - PK Series
Square Shape Instrument - PK Series PK-series is a square type meter. 4 difference degree type for this square PK-series:120mm, 100mm, 80mm & 60mm. Panel cut dimension is conformity with JIS C 1103. PK
More informationMOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES
MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES AMMETERS and VOLTMETERS MA12 MA19 MA17 MA16 MB16 MA16, MB16, MA17, MA19 and MA12 moving-coil meters are intended for measuring
More informationMX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories
MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional
More informationInternational Instruments Edgewise Panel Meters
International Instruments Edgewise Panel Meters 3 1 /2" and 6" Switchboard Meters Accuracy: ±1.5% (1151/1251) Single (1146/1151) or Dual Indicators (1246/1251) Rugged Construction Flush Stacking EMI Shielded
More informationVA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features
TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal
More information75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.
Hoyt VU Meters Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A. The VU meter is the standard level indicator for audio frequency transmission
More informationBulletin 871P Can Sensors
Bulletin 871P Can Sensors Description Bulletin 871P inductive proximity can sensors are self-contained solid state devices, designed specifically for sensing size 202 to 704 metal cans without physical
More informationNon-Spring Return EconoDrive Floating Actuator
MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationDifferential pressure sensor
s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationVersatile and Powerful
AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationSeries P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC9733 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationVersatile and Powerful
LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)
More informationModel 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO
M Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO GSAFETY WARNINGS The circuit under test must be switched off and de-energised before test connections are made
More informationTemperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.
Solid State Relays Vdc Input/ Output, Input/ Output High Reliability Shown smaller than actual size ac Controlled used with Controller with dc Voltage Driver Output L Typically ac Controlled used with
More informationSafety Standards. Model Number:
Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,
More informationSeries P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC 0435 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More informationUnit 10 Measuring Instruments
Objectives: Unit 10 Discuss the operation of a d Arsonval meter movement. Connect a voltmeter to a circuit. Read an analog multimeter. Connect an ammeter. Measure resistance using an ohmmeter. Analog meters
More informationLow voltage AC drives
General machinery drives Main features and dimensions Unique features Fast and extensive I/O PID control Application macros Many installation possibilities 200 to 480 V, 1-phase or 3-phase More value for
More informationDKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
More informationSWITCHGEAR. 4G cam switches
SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear
More informationELECTRICAL PANELS. Chap.
ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch
More informationScheda prodotto Relè Series E
Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range
More informationMODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)
1. Description: PC 252 is a Liquid-in-Metal expansion type Self powered Oil/ Winding Temperature Indicator for Power & Distribution transformers. PC 252 is Approved & Used by all reputed customers in India
More informationABB component drives ACS150, 0.5 to 5 Hp
ABB component drives ACS150, 0.5 to 5 Hp Technical Catalog BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES Contents Choice 1: Simply contact your local ABB drives sales office
More informationPRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY
Sheet 1 of 7 Order Number Serial Number PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Issue Date Level C /04/1996 Initial issue. Summary of changes Due to RMS continuous product improvement
More informationActuators for small valves
Actuators for small valves with 5.5 mm nominal stroke 4 891 SSB31... SSB81... 80130 80117 SSB... without auxiliary switch SSB...1 with auxiliary switch Electro-mechanical actuators for valve types VMP45...,
More informationOEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250
Data sheet OEM Pressure Transmitters for heavy-duty applications Type MBS 100 and MBS 150 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme
More informationBasic Series Accessories Low Voltage Current Transformer Class 1
Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationPower Product Specifications
Power Product Specifications Boost Power > Boost s ingenious and versatile design makes it compatible with a whole host of locations, from under tables and seats, to table tops, to between arms. Convenient
More informationTel: &
C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer
More informationJOSLYN CLARK VACUUM CONTACTORS
COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationB2, B3, B4, B5, B6 Measuring shunts
Features: Class 0.2 1A... 18 ka Class 0.5 DIN 35 mm Extension of d.c. current measuring ranges of moving-coil ammeters. Accuracy class 0.2 or 0.5 for ranges 2500 A, class 0.5 for ranges > 3000 A. Shunts
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)
TECHNICAL DATASHEET #TD1101AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version) Part No.: CAPV-H-10V-x complete with cable CAPV-S7C-yM Where: x = current output (2A, 1.2A or 600MA) y
More informationPressure sensor for liquid and gaseous media QBE620-P...
1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal
More informationSolenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER
EVI 7 S8 Solenoid System COIL The EVI7 S8 system by AMISCO includes a wide range of solenoid operators designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of
More informationMS Application. Features. Proportional Valve Actuator General Instructions
Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and
More informationOEM Pressure Transmitters
OEM Pressure Transmitters Type MH-2 Applications Mobile hydraulic systems Automotive industry Compressor systems Special Features Pressure ranges from 1000 psi to 8000 psi 4-20 ma, 1-5V, 0-10V, 0.5-4.5V
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationSeries P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)
PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression
More informationThe Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC
The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are
More information3 Uninterruptible Power Systems
3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential
More informationDo not risk your safety!
Analog Panelmeters Do not risk your safety! ANALOG PANELMETERS ANALOG G Analog Panelmeters ANALOG PANELMETERS Features For measurement of AC currents and voltages Good read-out survey on larger distance
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationDescription 1/8-7.5HP
Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.
More informationPrinciples and types of analog and digital ammeters and voltmeters
Principles and types of analog and digital ammeters and voltmeters Electrical voltage and current are two important quantities in an electrical network. The voltage is the effort variable without which
More informationPositions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No
029,1*,521 92/70(7(5 :,7+ &+$1*( 29(5 6:,7&+ 72VS, 96VS, 144sVS, 72VS-1, 96VS-1, 144sVS-1 The instruments are suitable for measuring AC voltages in 4 or 3-wire networks by using a change over switch mounted
More information1329I Integrated Drive/Motor CE Filter Option Kit
Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationPPT 802, Proximity Probe Transducer System
PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current
More informationDifferential Pressure Sensors
1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationCD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description
Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationFM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES
G2 SERIES G2 Industrial METER MODULES FM Approved Remote Kit Assembly (Part No. 113275-1) Maintains FM Approval. Accommodates fluid temperatures from -40 F to +250 F (-40 C to +121 C) depending on meter.
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More information