Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

Size: px
Start display at page:

Download "Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION"

Transcription

1 Crompton AC Overload Ammeters X6 Overload Scaling for Motor Start Duty True RMS Reading, Self Contained 50/60Hz 3 1 /2", 3 /16 DIN & 1 /4 DIN sizes Fiesta Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ Accuracy 2.5% shortscale, 1.5% longscale Burden 0.5VA shortscale, 1.5VA longscale Shortscale (90 ) Longscale (240 ) 5A A A-LSLS-C A-LSLS-C7 10A A A-MTMT-C A-MTMT-C7 15A A A-NDND-C A-NDND-C7 20A A A-NGNG-C A-NGNG-C7 30A A A-NLNL-C A-NLNL-C7 60A A A-NWNW-C7-80A A A-PDPD-C7-5A Transformer rated A-LS**-C A-LS**-C7 Also available with X2 & X3 overload scaling Crompton 4-IN-1 Panel Meters 96mm 1 /4 DIN case Mixed functions AC voltmeter: 110, 120, 200, 230, 240, 380, 400, 415, 440, 480V AC nominal. Maximum end scale 600 volts Frequency meter: 45/55Hz, 55/65Hz, 45/65Hz, 360/440Hz AC ammeter: 1 or 5A input (from CT) Hours run: 110, 120, 220, 230, 240, 380, 400, 415, 440 volts; 50 or 60Hz Hours display: hours DC current: 250µA - 1A DC including 1, 5, 10, 20 and 4-20mA DC for transducer inputs DC volts: 50mV to 600V DC including 50, 60, 75 and 150mV for shunt inputs Burden: Current: 0.75VA per phase Hours run: 2.5VA LCD hours run: 0.5VA Voltage: 0.5VA Frequency: 4VA When ordering please specify the inputs for each parameter and the scaling required N SPECIFICATIONS DIN Panel Meters SPECIFICATIONS/ Class 1.5, Burden 0.5VA (specify 50 or 60Hz) 72x72 Shortscale 72x72 Longscale 5A A E A-LSLS-C LSLS-C7 10A A E A-MTMT-C MTMT-C7 15A A E A-NDND-C NDND-C7 20A A E A-NGNG-C NGNG-C7 30A A E A-NLNL-C NLNL-C7 5A Transformer rated E A -LS**-C LS**-C7 96x96 Shortscale 96x96 Longscale 5A A E A-LSLS-C LSLS-C7 10A A E A-MTMT-C MTMT-C7 15A A E A-NDND-C NDND-C7 20A A E A-NGNG-C NGNG-C7 30A A E A-NLNL-C NLNL-C7 5A Transformer rated E A -LS**-C LS**-C7 144x144 Shortscale 144x144 Longscale 5A A LSLS-C LSLS-C7 10A A MTMT-C MTMT-C7 15A A NDND-C NDND-C7 20A A NGNG-C NGNG-C7 30A A NLNL-C NLNL-C7 5A Transformer rated LS**-C LS**-C7 DIN meters also available with X2 & X5 overload scaling ** state required scaling at time of order Model Description C ACV + DCI + ACA + DCA D 3 x DCI + DC ETM (LCD) G 3 x ACA H 3 x ACV + FRQ I 3 x ACA + ETM J 3 x ACA + ETM (LCD) K FRQ + ACV +DCI N ACA + ACV + FRQ + ETM P 3 x ACV Q ACV // FRQ // ETM + ACA R ACV // ETM + 2 x ACV S 2 x ACV + 2 x ACA T FRQ // ETM + ACV U 3 x ACA + ACV W TM // FRQ + DCI + ACV X 4 x DCI Y ETM // FRQ + DCI Z ACV + ACA + FRQ // ETM x ACV + ACA + ETM ACV + FRQ + 2 x ACA x ACA + DCI x ACV + ACA V, Hz, ETM + SWITCH NEW ACV = Rectified AC voltmeter ACA = Rectified AC ammeter DCA = DC ammeter DCI = DC indicator ETM = Elapsed time meter ETM(LCD) = LCD elapsed time meter FRQ = Frequency meter // = In parallel with

2 Crompton DIN Panel Meters 48, 72, 96 & 144mm Case Sizes 1.5% Accuracy Class 90 & 240 Versions Moving Coil DC Ammeters and Voltmeters The linear scale is calibrated down to zero & accuracy maintained down to 10%. Accuracy: Class 1.5 Impedance: Voltmeters: 1000Ω/V above 1V Millivolt meters use a 5mA movement. Ammeters: 75mV internal shunt above 60mA Model 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm Short Scale (90 ) DC Ammeters E242-89A E243-01A E244-01A A Ammeters E242-89C E243-01C E244-01C C DC Voltmeters E242-89V E243-01V E244-01V V Voltmeters E242-89N E243-01N E244-01N N Long Scale (240 ) DC Ammeters A A A A Ammeters C C C C DC Voltmeters V V V V Voltmeters N N N N Suppressed zero (e.g. 4-20mA, 1-5V) models also available. DC Ammeter DC Voltmeter 200 µa EAEA 50 mv HYHY 250 µa EBEB 60 mv JCJC 400 µa EIEI 75 mv JDJD 600 µa EQEQ 100 mv JRJR 1 ma FAFA 150 mv JX JX 1.5 ma FDFD 250 mv KDKD 2.5 ma FKFK 400 mv K JK J 5 ma FXFX 600 mv KPKP 6 ma GCGC 1 V LALA 10 ma GZGZ 1.5 V LCLC 15 ma HCHC 2.5 V LFLF 20 ma HFHF 4 V LLLL 25 ma HJHJ 5 V LSLS 40 ma HSHS 6 V LWLW 100 ma HZHZ 10 V MTMT 250 ma KDKD 15 V NDND 400 ma K JK J 20 V NGNG 600 ma KPKP 25 V NJNJ 1 A LALA 40 V NPNP 1.5 A LCLC 60 V NWNW 2.5 A LFLF 100 V PKPK 4 A LLLL 150 V PZPZ 5 A LSLS 250 V RSRS 6 A LWLW 400 V SCSC 10 A MTMT 500 V SFSF 15 A NDND 600 V SJSJ 25 A NJNJ 30 A NLNL 40 A NPNP Moving Iron AC Ammeters and Voltmeters Meters indicate true RMS values, substantially independent of system waveform. Scales are calibrated down to 20%. Accuracy: Class 1.5 Frequency: Burden: AC Ammeter 1 A LALA 1.5 A LCLC 2.5 A LFLF 4 A LLLL 5 A LSLS 6 A LWLW 10 A MTMT 15 A NDND 20 A NGNG 25 A NJNJ 50 or 60Hz (specify) Ammeters: 0.5VA Voltmeters: 4.5VA maximum Model 48 x 48 mm 72 x 72 mm 96 x 96 mm 144 x 144 mm Short Scale (90 ) AC Ammeter E242-75A E243-02A E244-02A A AC Voltmeter E242-75V E243-02V E244-02V V Long Scale (240 ) AC Ammeter A A A A AC Voltmeter V V V V Frequency Meters Frequency meters use an integral electronic converter and a moving coil indicator. Accuracy: Class 0.5 Burden: 4VA maximum DIN Short Scale DIN Long Scale AC Voltmeter 150 V PZPZ 300 V RXRX 400 V SCSC 600 V SJSJ DIN Frequency Model 48 x 48 mm 72 x 72 mm 96 x 96 mm Short Scale (90 ) E242-41S E243-41S E244-41S 45/55Hz 55/65Hz 45/65Hz 360/440Hz V AC PLAG-AG PLAN-AN PLAJ-AJ PLBI-BI V AC RNAG-AG RNAN-AN RNAJ-AJ RNBI-BI To Order: Specify Model followed by Example: E242-75V-PZPZ General Specifications: Environment: -20 C to +60 C Case: UL94VO polycarbonate case, glass window, IP52 Depth: 64mm Standard dials are white matte with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available. 72

3 Hoyt Industrial & Military Panel Meters Round Panel Meters Metal or Phenolic Case 2 1 /2" /2" Sizes DC & AC Types Wide Variety of Options Military Qualified Versions (2 1 /2" & 3 1 /2") 17/3 SPECIFICATIONS Movement: DC moving coil, AC repulsion Accuracy: 2% of full scale Case: Metal or phenolic, with glass front Dimensions: Bezel dia. Body dia. Depth behind panel 17/3-P, 552-P 2.69" 2.20" 1.88" 17/L-P, 560-P 3.22" 2.50" 1.88" 582-P, 584-P 3.50" 2.75" 1.89" 574P, 617P 4.50" 3.75" 1.95" 17/3-WR, 552-WR 2.55" 2.06" 1.83" 17/L-WR, 560-WR 3.22" 2.50" 1.94" 570-WR, 580-WR 3.66" 3.00" 2.09" 574-WR, 617-WR 4.50" 3.75" 1.89" Terminals: studs Options: Color bands, white on black dial, wide or narrow bezel, straight side metal case, LED illumination, 1/4-28 studs, pointer style, pointer color. Also available: 6351/2 Series 3 1 /2" Metal Case Sealed Meters for extreme duty applications. To Order Insert Number for Each Letter to Select Catalog Number. A B C D E Example: 17/3-P-5mADC-300GPM A B C D E Model 17/3 2 1 /2" DC meter /2" AC meter 17/L 3" DC meter 560 3" AC meter /2" DC meter (phenolic case only) /2" AC meter (phenolic case only) /2" DC meter (metal case only) /2" AC meter (metal case only) /2" DC meter /2" AC meter Case P Phenolic case WR Wide rim metal case MM Sealed metal case Standard s DC 20, 50, 100, 200, 500uA 1, 2, 5, 10, 20, 50, 100, 200, 500mA & 4-20mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 750V AC 10, 20, 50, 100, 200, 500mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 600V Scale Specify range and legend Options 250 DC Meters High Impact Metal Case 2", 3" and 3-3/8" Sizes 2% Accuracy Illumination Option 250 SPECIFICATIONS Movement: Highly damped pivot & jewel Deflection: 250 degrees Accuracy: 2% standard, 1% available Case: Iron case standard, brass case available Dimensions: Bezel diameter 2.29" 3.32" 3.80" Body diameter 2.05" 3.00" 3.36" Depth behind panel 2.51" 2.50" 2.50" Terminals: studs Other options: Color bands, white on black dial, bezel style, pointer style. To Order Insert Number for Each Letter to Select Catalog Number. A B C D E Example: BL-5mADC-5mADC-RP A B C D E Model " meter " meter /8" meter Bezel BL Black CHR Chrome Standard s DC 20, 50, 100, 200, 500uA 1, 2, 5, 10, 20, 50, 100, 200, 500mA & 4-20mA 1, 2, 5, 10, 20, 50A 50, 100, 150, 300, 500mV 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 750V Scale Specify range and legend Options RP Red pointer BP Black pointer IL Illumination (specify 12 or 24 VDC) 73

4 LFE/API Analog Panel Meters Replacements for popular styles and sizes 7000 Series Phenolic case, glass window 2 1 /2" /2" /2" /2" 7055 Meteor Series 2 1 /2" /2" /2" /2" 604 Panelist Series Black phenolic case, glass window 3 1 /2" /2" /2" 603 Clear plastic case & window 2 1 /2" /2" /2" /2" 602 Round Series Polycarbonate case, plastic or glass window 3 1 /2" 1235 Edgewise Series 1 1 /2" /2" /2" /2" shielded 371 Ruggedized Series Sealed metal case 2 1 /2" /2" /2" 455 See more info online at weschler.com/lfe A&M Ruggedized Panel Meters Steel Case, Glass Window Watertight Magnetic Shielding (90 models) Mounting per Mil-M-10304E Accuracy 90 : 2% DC & Iron Vane, 3% Rectifier Type 250 : 1% DC, 2% Rectifier Type To order: specify model, input & scale Style/Size Model Type 90 Round 2 1 /2" 263 AC Rectifier Type 264 RF Core Magnet 265 DC Core Magnet 266 AC Iron Vane 3 1 /2" 363 AC Rectifier Type 364 RF Core Magnet 365 DC Core Magnet 366 AC Iron Vane 90 Square 1 1 /2" 133 AC Rectifier Type 135 DC Core Magnet 2 1 /2" 233 AC Rectifier Type 235 DC Core Magnet 236 AC Iron Vane 250 Round 2 1 /2" 2432 AC Rectifier Type 2452 RF Core Magnet 3 1 /2" 3432 AC Rectifier Type 3452 DC Self-shielding 4 1 /2" 443 AC Rectifier Type 445 DC Self-shielding 74

5 Hoyt Illuminated Meters Features bright white, even backlighting with no hot spots or shadowing. No holes to drill or bulbs to burn out Series 5000 Series Window, Surface & Bezel Mount Many Voltage & Current s UL Recognition Optional Accuracy 2% of Full Scale Vibration & Harsh Environment Resistant Many Voltage & Current s UL Recognition Optional Accuracy 2%, except Rectifier Type 3% Size Model Type 1 1 /2" 3115 DC Moving Coil 3116R AC Rectifier Type 2 1 /2" 3125 DC Moving Coil 3126 AC Repulsion 3 1 /2" 3135 DC Moving Coil 3136 AC Repulsion 4 1 /2" 3145 DC Moving Coil 3146 AC Repulsion ELumination Lighting (Optional on 3100 & 5000 series meters) Light Intensity: ft-l Power Required: 3 18VDC, 60mA max. Triplett Analog Panel Meters Replacements for popular styles and sizes Size Model Type 1 1 /2" 5015 DC Moving Coil 5016R AC Rectifier Type 2 1 /2" 5025 DC Moving Coil 5026 AC Repulsion 3 1 /2" 5035 DC Moving Coil 5036 AC Repulsion Line Frequency Meters also available To order: Specify model, input & scale G Series 1 1 /2" 120-G 2 1 /2" 220-G, 230-G 3 1 /2" 320-G, 330-G 4 1 /2" 420-G, 430-G 5 1 /2" 520-G, 530-G R Series 4 1 /2" 420-R, 430-R GL Series Glass window, plastic case 2 1 /2" 220-GL, 230-GL 3 1 /2" 320-GL, 330-GL 4 1 /2" 420-GL, 430-GL 5 1 /2" 520-GL, 530-GL Phenolic Series Glass window, phenolic case 2 1 /2" rectangular 227-T, 237-S 3 1 /2" rectangular 327-T, 337-S 4 1 /2" rectangular 420, /2" rectangular 626, /2" round 221-T, 231-S 3 1 /2" round 321-T, 331-S GL/B Series Glass window, plastic case, integral bezel 3 1 /2" 320-GL/B, 330-GL/B 4 1 /2" 420-GL/B, 430-GL/B 5 1 /2" 520-GL/B, 530-GL/B Ruggedized Series Plastic window, steel case, sealed 1 1 /2" rectangular 127-HR 2 1 /2" round 221-HR 3 1 /2" round 321-HR See more info online at weschler.com/triplett 75

6 Hoyt VU Meters Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A. The VU meter is the standard level indicator for audio frequency transmission systems. VU meters are used to measure sound or noise levels in broadcast monitoring, public address systems and anywhere volume level measurements are to be made. The VU also is useful for the measurement of noise level and other audio frequency energy where the established dynamic characteristics of the VU meter give a common result for measurements taken in different laboratories. The VU meter is designed to read zero VU or 100% with volts applied to the instrument and the 3600 ohm series resistance. This represents 4 db above 1 milliwatt in 600 ohms. The combination of a special copper oxide rectifier and an extremely sensitive movement with special magnetics give these meters very high sensitivity. Two scales types are available with white, black or buff background color. A black pointer is standard, red optional. TYPE A SCALE The "A" Scale reads "-20 to +3" in type on the top of the arc, with "0-100" in type on the bottom of the arc. TYPE B SCALE The "B" Scale reads "0-100" in type on the top of the arc, with "-20 to +3" in type on the bottom of the arc. To order: Specify model, mounting, scale type/color, VU Custom legends & logos available on request /3 Size Model Style 1 1 /2" Rectangular, panel or bezel mount 3115 Rectangular, surface or window mount 2 1 /2" 17/3 Round, phenolic 2025 Rectangular, panel or bezel mount 635 Rectangular, phenolic 685 Edgewise 3125 Rectangular, surface or window mount 4025 Rectangular, phenolic & glass 3 1 /2" 2035 Rectangular, panel or bezel mount 2135 Rectangular, low profile phenolic 582 Round, phenolic 597 Rectangular, phenolic 3135 Rectangular, surface or window mount 4035 Rectangular, phenolic & glass 4 1 /2" 2045 Rectangular, panel or bezel mount 2145 Rectangular, low profile phenolic 647 Rectangular, phenolic 3145 Rectangular, surface or window mount 4045 Rectangular, phenolic & glass 75a

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5 to 4.5 Choice of Styles & Mounting Made in U.S.A. Hoyt VU Meters Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A. The VU meter is the standard level indicator for audio frequency transmission

More information

International Instruments Edgewise Panel Meters

International Instruments Edgewise Panel Meters International Instruments Edgewise Panel Meters 3 1 /2" and 6" Switchboard Meters Accuracy: ±1.5% (1151/1251) Single (1146/1151) or Dual Indicators (1246/1251) Rugged Construction Flush Stacking EMI Shielded

More information

LED Digital Analog Combination

LED Digital Analog Combination Crompton Instruments model 007-DI features a combination of the traditional 250 4 1 2" switchboard indicator with the trend indication plus the benefits of wide angle LED visibility. This rugged shock

More information

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

Century Style Analog Panel Meters

Century Style Analog Panel Meters UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

Weschler Analog Edgewise and Panel Meters

Weschler Analog Edgewise and Panel Meters Weschler Analog Edgewise and Panel Meters Type 252 edgewise instruments were designed specifically for the nuclear power industry. Their ruggedness and reliability make them an excellent choice for any

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Smart Look Series Meter

Smart Look Series Meter File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter 212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96 Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide

More information

240 Series DIN Panel Meters

240 Series DIN Panel Meters An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering measurement of all electrical and electronic parameters. Meters are shock resistant and vibration proof and supplied with terminal

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter C R LISTED File No. E471457 Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

PLATINUM SERIES SWITCHBOARD METERS

PLATINUM SERIES SWITCHBOARD METERS PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders

More information

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic

More information

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant Elapsed Time Meters Devices will match the frequency of AC power systems. Six-digit counters record hours, tenths of hours, minutes

More information

PANEL METER CATALOG

PANEL METER CATALOG PANEL METER CATALOG 18002583652 WWW.HOYTMETER.COM Case Style & Construction 1000 Series 41/2 21/2 31/2 Page 9 Phenolic and Glass Meters 4000 Series 21/2 31/2 41/2 Page 16 1025/26 1037/38 1045/46 Clear

More information

Technical Data Sheet Sigma Series DS Meter

Technical Data Sheet Sigma Series DS Meter Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments

More information

Crompton Instruments. ANSI Switchboard Meters

Crompton Instruments. ANSI Switchboard Meters Crompton Instruments ANSI Switchboard Meters www.crompton-instruments.com Crompton Instruments ANSI SWITCHBOARD METERS An extensive range of analog and digital/analog meters in the 4½" ANSI case style.

More information

Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DG Meter Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear

More information

Price List Effective from :

Price List Effective from : List Effective from :- 01-04-2018 INDICATING MOVING IRON, MOVING COIL VOLTMETER & AMMETER ME BRAND Moving Iron Instruments are generally used for measuring A.C. Voltage and currents. These are Repulsion

More information

SIGMA SERIES DE METER

SIGMA SERIES DE METER SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

WESCHLER INSTRUMENTS. Weschler Analog Switchboard Meters TAUT-BAND SUSPENSION FULL VIEW DESIGN MODIFICATIONS AVAILABLE.

WESCHLER INSTRUMENTS. Weschler Analog Switchboard Meters TAUT-BAND SUSPENSION FULL VIEW DESIGN MODIFICATIONS AVAILABLE. Weschler Analog Switchboard Meters High accuracy, full view design Volts, amps, watts, vars, speed, frequency and power factor High overload capacity Military and Nuclear versions Ultimate in reliability

More information

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution. 88 Metering Solution-Oriented Metering Keeping track of onboard systems is critical to safety and peace of mind. Running low on fuel or not knowing about a failing battery can lead to dangerous situations.

More information

070 Series ANSI Switchboard Meters

070 Series ANSI Switchboard Meters Approvals UL Approved File No: E87815 This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 (1981) accuracy class 1. Available in two case sizes, their

More information

Panel Meters and Accessories Digital Panel Meter

Panel Meters and Accessories Digital Panel Meter Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor

More information

DIN Rail Mounting Bracket

DIN Rail Mounting Bracket DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated

More information

Technical Data Sheet Sigma Series DE Meter

Technical Data Sheet Sigma Series DE Meter Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency

More information

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Portable Instruments. Bulletin 2000-E

Portable Instruments. Bulletin 2000-E Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments

More information

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144 Data Sheet Analogue Meters with Moving - Iron Movement Tel. +91 253 22216, 22222 Fax +91 253 235164 E-mail India - marketing@rishabh.co.in

More information

Voltmeter and Ammeter Design

Voltmeter and Ammeter Design EEE3406 Instrumentation & easurements LABOATOY Experiment 2 Name Class Date Class No. arks Voltmeter and Ammeter Design Objectives: After completing this lab, you will be able to measure the full-scale

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

Standard Program Technical Description

Standard Program Technical Description Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable Scales Meter s scale

More information

2. Analog measurement of Electrical Quantities

2. Analog measurement of Electrical Quantities 2.1. Classification of Analog Instruments Definition and concept of Measurement The analog instruments can be classified on the basis of various parameters. Analog Instruments On the basis of measuring

More information

Electrical Measuring Instruments

Electrical Measuring Instruments UNIT 12 Electrical Measuring Instruments Learning Objectives After studying this unit, the student will be able Understand different measuring instruments used in electricity Understand the working of

More information

Classic style with a name you can trust

Classic style with a name you can trust Classic style with a name you can trust Bosch is known for precision, engineering, and innovation. Add style and you have the first-ever line of Bosch gauges, including replacement tachometers, speedometers,

More information

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No 029,1*,521 92/70(7(5 :,7+ &+$1*( 29(5 6:,7&+ 72VS, 96VS, 144sVS, 72VS-1, 96VS-1, 144sVS-1 The instruments are suitable for measuring AC voltages in 4 or 3-wire networks by using a change over switch mounted

More information

2011 Special OEM Instrumentation Catalog

2011 Special OEM Instrumentation Catalog www.vdo.com/usa 2011 Special OEM Instrumentation Catalog Part #VSOC0510 (Supersedes Part #VSOC0908) Instrumentation Sensors A heritage of engineering quality and innovation We re focused on providing our

More information

Principles and types of analog and digital ammeters and voltmeters

Principles and types of analog and digital ammeters and voltmeters Principles and types of analog and digital ammeters and voltmeters Electrical voltage and current are two important quantities in an electrical network. The voltage is the effort variable without which

More information

Instrumental technique presentation

Instrumental technique presentation Instrumental technique presentation ammeter Manju 28.10.2017 An ammeter is a measuring instrument used to measure the electric current in a circuit. History I A The relation between electric current, magnetic

More information

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES AMMETERS and VOLTMETERS MA12 MA19 MA17 MA16 MB16 MA16, MB16, MA17, MA19 and MA12 moving-coil meters are intended for measuring

More information

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers www.murata-ps.com Now Available with Wire Lead CTs FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry Precision A/D

More information

Unit 10 Measuring Instruments

Unit 10 Measuring Instruments Objectives: Unit 10 Discuss the operation of a d Arsonval meter movement. Connect a voltmeter to a circuit. Read an analog multimeter. Connect an ammeter. Measure resistance using an ohmmeter. Analog meters

More information

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

MAINTENANCE INFORMATION ====================

MAINTENANCE INFORMATION ==================== CHAPTER 1 MAINTENANCE INFORMATION ==================== C O N T E N T S TEST EQUIPMENT REQUIRED SECTION 1 Page 3 FAULT FINDING & SERVICING NOTES SECTION 2 Page 3 VOLTAGE CHECKS WITH NO VALVE UNDER TEST

More information

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION Cases GENERAL INSTALLATION Westinghouse I.L. 43-250-F OPER.ATION MAINTENANCE INS T R U c.t I 0 N S The first letter in type designates the form of case used. U =Rect. Proj. Base M't'd 5'/z" x 5'/z". K

More information

Chapter 9 Basic meters

Chapter 9 Basic meters Chapter 9 Basic meters Core Competency Units UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE004B Solve problems in multiple path DC Circuits Essential Knowledge and Associated

More information

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. Experiment o. 1 AME OF THE EXPERIMET To study the constructional features of ammeter, voltmeter, wattmeter and energymeter. OBJECTIVE 1. To be conversant with the constructional detail and working of common

More information

Product Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.

Product Information. Viewline Temperature gauges.  Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature. Product Information www.vdo.com Viewline Temperature gauges Description Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature. Features _ Integrated Warning LED. _ Changeable Frontbezels.

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

VDO cockpit vision / international

VDO cockpit vision / international VDO cockpit vision / international Instruments www.siemensvdo.com TU00-0755-0000002 I 0607 I Technical details subject to change Contents Page 14 1 General informations 14-2 14 2 Technical data 14-3 14

More information

BASIC ELECTRICAL MEASUREMENTS By David Navone

BASIC ELECTRICAL MEASUREMENTS By David Navone BASIC ELECTRICAL MEASUREMENTS By David Navone Just about every component designed to operate in an automobile was designed to run on a nominal 12 volts. When this voltage, V, is applied across a resistance,

More information

Tachometers and Tach/Hourmeters AT and ATH Series

Tachometers and Tach/Hourmeters AT and ATH Series Tachometers and Tach/Hourmeters AT and ATH Series Installation Instructions 00-02-0986 Section 70 IMPORTANT! These instructions are specific to tachometer models with a single calibration push button.

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control Accuracy: ±% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or Stainless

More information

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or

More information

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers www.murata-ps.com Now Available with Wire Lead CTs C US E156931 FEATURES for direct measurement of 0 to 2/20/50/100 Amps Functionally complete: On-board current transformers Scaling/interface circuitry

More information

Technical portal and online community for Design Engineers -

Technical portal and online community for Design Engineers - Technical portal and online community for Design Engineers - www.element14.com 1987 Page Page 4 to 20mA Process Indicators... 1989 LCD Digital... 1987 Current Transformers... 1995 LED Digital... 1990 Easy

More information

EKT112 Principles of Measurement and Instrumentation. Power Measurement

EKT112 Principles of Measurement and Instrumentation. Power Measurement EKT112 Principles of Measurement and Instrumentation Power Measurement 1 Outline Power? Power in DC and AC Circuits Power Measurements Power Instrumentation (Wattmeter) 2 Concept of Electric POWER Power

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Various cap styles and colors to meet differing application needs. Bright, full face illumination to distinctively indicate status. Rear panel threaded mounting or snap-in mounter

More information

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Sheet 1 of 7 Order Number Serial Number PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Issue Date Level C /04/1996 Initial issue. Summary of changes Due to RMS continuous product improvement

More information

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO M Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO GSAFETY WARNINGS The circuit under test must be switched off and de-energised before test connections are made

More information

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE

More information

Meters Product Selection Guide

Meters Product Selection Guide Meters Product Selection Guide Bulletin 22-E C O N T E N T S P 4 Product Line-up P 6 Portable Precision Instruments P 12 Switchboard Instruments 21A Series P 16 Panel Meters CLEAR LINE Series P 2 Panel

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Square Shape Instrument - PK Series

Square Shape Instrument - PK Series Square Shape Instrument - PK Series PK-series is a square type meter. 4 difference degree type for this square PK-series:120mm, 100mm, 80mm & 60mm. Panel cut dimension is conformity with JIS C 1103. PK

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot. TRIPLETT Model 310 Type 9 310-C Type 9 Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com TABLE OF CONTENTS SAFETY RULES... 2 INTRODUCTION...8 SPECIFICATIONS...

More information

Single-phase CT current transformers Cat. Nos :

Single-phase CT current transformers Cat. Nos : Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type

More information

Precision Bourdon tube pressure gauges

Precision Bourdon tube pressure gauges Pressure gauges Precision pressure gauges High accuracy (class 0.6) Housing can be plumbed Serial number on dial Suitable as measuring equipment as per QA requirements DNV- and GOSSTANDART-certified A

More information

Technical information

Technical information Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary

More information

Wind display type WSDI-2 DATA SHEET

Wind display type WSDI-2 DATA SHEET Wind display type WSDI-2 DATA SHEET Displays Read-out Approval Housing Relative or true wind speed and direction Wind speed in: m/s, knots or Beaufort Black base, white lines and figures 4-digit 7-segment

More information

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter. OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents

More information

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www. BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0 Take off the fuse,

More information

New Products Programs & Packaging

New Products Programs & Packaging #3 Catalog New Products Programs & Packaging from NEW Performance Products Custom instruments engineered to give you the reliability and accuracy you need on the street, off road or track. The choice of

More information

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS LB-60-30 LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS 4031 W Kiehnau Ave Milwaukee, WI 53209 CAUTION THIS LOAD BANK IS DESIGNED FOR THE TESTING AND SERVICING

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

BRIEF OF PROFILE OF SEW

BRIEF OF PROFILE OF SEW BRIEF OF PROFILE OF SEW www.sew.com.tw History In 1973 Mr. and Mrs. Stanley Shay established the Standard Electric Works Co., Ltd. (SEW) in Pan Chiao, Taipei Hsien, Taiwan to manufacture and market various

More information

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load

More information

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays Displays Relative or true wind speed and direction Wind speed in: m/s, knots or Beaufort Read-out Black base, white lines and figures 4-digit 7-segment red display Approval Major class approvals, see homepage

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions CP-8551 & CP-8552 Electronic to Pneumatic Transducers General Instructions Application The CP-8551 and CP-8552 transducers receive a variable electronic input signal and produce a 3 to 15 psig (21 to 103

More information

POWER DIGITAL SWITCHBOARD METERS

POWER DIGITAL SWITCHBOARD METERS POWER S POWER SERIES Plus Other Catalogs Available... Power Transducers Current & Potential Transformers Yokogawa Juxta Power Transducers (models 2469, 2489) are UL recognized and enclosed in a rugged

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

+5V A/D CONVERTER 5V SIGNAL + GROUND Open on isolated-supply models TB1. Applies to isolated-supply models only EXTERNAL + LOAD

+5V A/D CONVERTER 5V SIGNAL + GROUND Open on isolated-supply models TB1. Applies to isolated-supply models only EXTERNAL + LOAD Order online at www.datel.com Features Built-in shunts for digitally measuring dc currents from 00uA to 0A! Functionally complete---no additional components required Wide power supply inputs: 5 to 40Vdc

More information

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc. POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

POWER SERIES DIGITAL SWITCHBOARD METERS. Plus

POWER SERIES DIGITAL SWITCHBOARD METERS. Plus POWER SERIES S Plus POWER SERIES Plus Other Catalogs Available... Power Transducers Current & Potential Transformers Yokogawa Juxta Power Transducers (models 2469, 2489) are UL recognized and enclosed

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

ELECTRICAL MEASURING INSTRUMENT CHAPTER 15 ELECTRICAL MEASURING INSTRUMENTS THE MOVING COIL GALVANOMETER The moving coil galvanometer is a basic electrical instrument. It is used for the detection or measurement

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face or spot illumination with incandescent lamps or multi-element LEDs, with or without resistors. Short Body Pushbuttons Series YB Choice of super bright LEDs in white,

More information

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS Features Description The 4:1 Input Voltage 150 W single HEW Series of DC/DC converters provide precisely regulated dc outputs. The output voltage is fully isolated from the input, allowing the output to

More information

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications: CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:

More information