1 CTB Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height: 80.5 mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm ² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 50 A up to 750 A es 3 and 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
2 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
3 CTB Plug-in current transformer Dimensions: Primary conductor 1: 40x10 mm Primary conductor 2: 30x15 mm Round conductor: 32 mm Transformer width: 70 mm Transformer height: 91 mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm ² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 75 A up to 1000 A es 3 and 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
4 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
5 CTB Plug-in current transformer Dimensions: Primary conductor 1: 50x12 mm Primary conductor 2: 40x30 mm Round conductor: 44 mm Transformer width: 85 mm Transformer height: mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 11 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 100 A up to 1250 A 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
6 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
7 CTB Plug-in current transformer Dimensions: Primary conductor 1: 63x10 mm Primary conductor 2: 50x30 mm Round conductor: 44 mm Transformer width: 95 mm Transformer height: 115 mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm ² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 200 A up to 1600 A 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
8 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
9 CTB Plug-in current transformer projected, deliverable within september 2010 Dimensions: Primary conductor 1: 80x10 mm Primary conductor 2: 60x30 mm Round conductor: 55 mm Transformer width: 120 mm Transformer height: 135 mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm ² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 400 A up to 2000 A 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
10 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
11 CTB Plug-in current transformer projected, deliverable within september 2010 Dimensions: Primary conductor 1: 100x10 mm Primary conductor 2: 80x30 mm Round conductor: 70 mm Transformer width: 130 mm Transformer height: 147 mm Total depth: 52 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 1.0 kv Isolation test voltage: 6 kv, U eff, 50 Hz, 1 Min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information: World's first CT with screwless connection technology for the secondary caps Cage Clamp Europe's first current transformer with UL certification Innovative time-saving connectivity of solid and flexible conductors with or without ferrules for max. 4 mm ² Vibration and shock resistant Maintenance-free, gas-tight connection High current-carrying capacity High mechanical holding forces Low voltage current transformers for max. operating voltage to 1.0 kv, use in 690 V networks possible Available for primary nominal currents from 400 A up to 2500 A 1 Constantly overloaded with 120 % of the primary rated current Over current rated limiting factor: See rating plate Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Unbreakable plastic housing of grey polycarbonate, self-extinguishing, UL94-V0, flame resistant Packaging unit: 1 pc. Customs tariff number:
12 Order list CTB Plug-in current transformer Secondary current 5A 1A Primary current Burden VA
Single-phase CT current transformers Cat. Nos :
Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type
More informationCURRENT TRANSFORMER - AST line
ST - C.T.`s line Technical comments Modern design, versatility and increased safety are the distinctive features of the new STline. In developing the new series we have moreover retained our reliable CELS
More informationBasic Series Accessories Low Voltage Current Transformer Class 1
Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating
More informationTel: &
C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer
More informationSIGMA SERIES DE METER
SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationTechnical information
Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary
More informationHan ES Press. Features. Description. Removal of conductor. Size 6 B - 24 B
Size 6 B - 24 B Features Easy bridging functionality of contacts by means of plug-in jumpers directly on the connector Fast realisation of potential multiplication as well as star and delta bridges Rapid
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationCurrent transformers. Current transformers
Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against
More informationFused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series
28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the
More informationLED control gear Compact fixed output
Driver LCI 65 W 1400/1750 ma TEC SR TEC series Product description Independent fixed output LED Driver Constant current LED Driver Output current 1,400 or 1,750 ma Max. output power 65 W Nominal life-time
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationenergy management systems Current Transformers
energy management systems 05 Current Transformers CURRENT TRANSFORMERS Current transformers with analogue output page 5/1 Busbars page 5/5 Current transformers ic Line page 5/6 Protective current transformers
More informationDC/DC converters - MINI-PS DC/ 5-15DC/
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMedium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...
More informationPOWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS
POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationHV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH
More informationTransformers for Low-voltage Halogen Incandescent Lamps
Transformers for Low-voltage Halogen Incandescent Lamps Independent electronic converters 10 14 With DLI interface 14 Electronic built-in converters 15 17 Potentiometer and dimmers 18 Electromagnetic safety
More informationTechnical Data Sheet Sigma Series DE Meter
Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency
More informationJCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3
Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationSEALED POWER TRANFORMERS BV SERIES EI30 0.6VA 2.8VA FEATURES OUTLINE DIMENSIONS
ZETTLER Magnetics, Inc. COLUMBIA ALISO VIEJO, CA 266 4-360-838 FAX 4-360-83 WEB SITE: HTTP://WWW.ZETTLERMAGNETICS.COM E-MAIL: SALES@ZETTLERMAGNETICS.COM FEATURES UL & VDE CERTIFICATION SMALL PHYSICAL FOOTPRINT
More informationSolenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5
2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly
More informationChapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design
Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly
More informationContactors RAST 5 D778E131
Contactors RAST 5 D778E131 RAST 5 - exclusive for OEM-Partners 5 mm pitch connector system Advantages RAST 5 - Technology 59 mm Time saving installation Easy assembly without tools Tailor-made sockets,
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationPRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH
GmbH PRODUCT INFORMATION USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands For use in the most important global markets Reduction in technical documentation
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationCURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)
MODEL N 4." I.D. PAGE No 1-30 TERMINAL OPTION LEAD WIRE OPTION 6.75 SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.75 1.36 1.16 5.75 7.00 0. x 0.50 SLOT (2 PLACES) UL 1015 #16
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationData sheet TERMSERIES TRZ 120VUC 1CO
relay module, complete modules consisting of a relay and a base with AC/DC/UC coils, available in different versions: With screw and tension-clamp connection AgNi contact, optionally with hard gold-plated
More informationRelax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More information1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4
T-LINE 1. Table of Contents Page 1. Table for contents 2 2. Description Current transformers type HF 3 3. Product Overview 4 4. Measuring accuracy VA Burden 5 5. Survey chart 0,5 1 3, type HF3A, HF3B and
More informationMINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial
More informationApprovals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL
More information200 SERIES THREADED VALVES PENTAIR CLEAN AIR SYSTEMS
THREADED VALVES PENTAIR CLEAN AIR SYSTEMS Lock nut DESCRIPTION The is a range of diaphragm valves suitable for dust collector applications, in particular for reverse pulse-jet filter cleaning of filter
More informationTechnical Data Sheet Sigma Series DG Meter
Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear
More informationPRODUCTS: POWER SUPPLY
PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER
More informationLA Motor Protection. A South African Company to be Proud of
LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More information2.1. NEMA Contactors and Starters
3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationSAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz
III Nominal voltages up to 30 kv / 50 Hz EN/IEC 61243-1 (DIN VDE 0682 411) Also for use in wet weather for indoor and outdoor installations With self-testing device Visual indicator Wide nominal voltage
More informationSTS 2,5. Extract from the online catalog. Order No.:
Extract from the online catalog STS 2,5 Order No.: 3036398 Feed-through modular terminal block, Connection method: Springcage connection, Spring-cage connection, Cross section: 0.08 mm² - 4 mm², AWG 28-12,
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and
More informationTechnical specifications
KINGDOM OF SAUDI ARABIA THE SAUDI FUND FOR DEVELOPMENT ( SFD) ITB -207-7 Technical specifications Project name: Reconstruction, Furniture and Equipping of Three Schools Photovoltaic Solar System for Holly
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationModular Contactors and Switches D681E121
Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency
More informationA7 Magnetic Contact/Switch CONTENTS
A7 Magnetic Contact/Switch CONTENTS A7-02 Magnetic Contact / Switch VMC9~85 Medium/Small Capacity VITZRO Magnetic Contact/Switch provides customers with the safety as the first priority which is the core
More informationDC Cabling Ready for 1,500 V DC
DC Cabling Ready for 1,500 V DC Perfectly connected MADE IN GERMANY Reduce your LCOE with 1,500V DC architecture What causes PV costs? Since 2010 the PV market has changed a lot. PV module costs have been
More informationAC Wattmeters and VArmeters
AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationDry Type Distribution Transformers
Low Temperature Rise SolaHD low temperature rise transformers feature a 220 C insulation system and temperature rise of only 80 C or 115 C under full nameplate load. Reduction in temperature rise increases
More informationSafety isolating transformer, IP20
Safety isoling transformers Safety isoling transformer, IP20 Standard types Type FR-PS Single-phase safety isoling transformer designed and tested according to EN61558-2-6. The construction is produced
More information300 SERIES DRESSER NUT VALVES PENTAIR CLEAN AIR SYSTEMS
DRESSER NUT VALVES PENTAIR CLEAN AIR SYSTEMS CONSTRUCTION FEATURES VALVE Cover Diecast aluminium (anodised) Body Diecast aluminium (anodised) Pilot base Brass (chromed) Pilot Diaphragm NBR Bolts and screws
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationProduct Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw
Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw 30A 208V 20A 208V 3 Phase 30A 208V 3 Phase Important Information Specifications Installation & Operation Outline & Wiring Drawings
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationLankelec CPA6-H. HB acc. to UL94 IP 68 acc. to EN Material Plastic (PA) Temperature range -30 up to +110, ^ +130
CPA6-H HB acc. to UL94-30 up to +110, ^ +130 - HB according to UL 94 - DIN 5510, part 2 dyn stat m/rings Kg/m grey AD10.0 6.50 10.0 15 15 50 21 0200.014.010 0200.014.210 AD13.0 10.0 13.0 20 20 50 27 0200.014.013
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationLED Driver Compact fixed output
Driver LC 45W 500 1400mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter
More informationLED Driver Compact fixed output
Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter
More informationSAC-4P-M12MS/ 5,0-PUR SH
Extract from the online catalog SAC-4P-M12MS/ 5,0-PUR SH Order No.: 1682647 Sensor/Actuator cable, 4-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Plug, straight M12, A-coded, on Free conductor
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationFuse switch disconnectors
SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY
More informationCATALOG. EasyLine XLP Fuse Switch Disconnector poles
CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction
More information7000 Series Buccaneer
Robust, rapid connections for harsh environments The all plastic construction 7000 Series Buccaneer - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing
More informationXM1 - Motor protection relay
XM1 - Motor protection relay Contents 1 Applications and features 1 Applications and features 2 Design 3 Working principle 3.1 Overload protection 3.2 Stalling protection 3.3 Earth fault protection 3.4
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationMECAIR 200 SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET
200 SERIES CLEAN AIR SOLUTIONS - 200 SERIES CONSTRUCTION FEATURES VALVE Lock nut DESCRIPTION COVER Diecast aluminium (anodised) BODY Diecast aluminium (anodised) PILOT BASE Aluminium (anodised) PILOT Stainless
More informationTHYRO-A DIGITAL THYRISTOR SCR POWER CONTROLLERS 8 TO 1500 AMPS
DIGITAL THYRISTOR SCR POWER CONTROLLERS 8 TO 1500 AMPS With highly flexible interfacing for the load and power supply side, Thyro-A modules precisely and reliably control power in an expanded range of
More informationApproved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories
Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved
More informationIsolating transformer ES710
Single-phase isolating transformers for the design of medical IT systems Also available as energy-efficient Green Line (GL) edition ES710_D00109_03_D_XXEN/10.2016 Single-phase isolating transformers for
More informationSE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR
SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR FEBRUARY 14, 2001 REVISION 3 Publication: SE-125-M Document: S95-C125-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.
More informationUSA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands
USA: UL-listed (MTW), Canada: CSA (TEW), Europe: H07V-K (depending on cross s.), tin-coated strands Lapp Kabel, power and control cable, PVC single core for field wiring, UL MTW VW-1, UL AWM style
More informationTechnical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush
Metal distribution boxes for flush and surface mounting Technical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush Number of
More informationTechnical Data Sheet Sigma Series DS Meter
Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments
More informationGeneral Purpose Buck - Boost Wiring Diagrams... 86
SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for
More informationOther Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions
Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device
More informationRotary Cam Switches. Rotary Cam Switches
Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationFuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A
www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 07-0 Fax: 0640 07-25 IT system floor-standing distribution cabinet Series -IPS-F for supplying power to medical locations
More informationNon-Spring Return EconoDrive Floating Actuator
MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationS840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en
Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break
More information