Low voltage circuit breakers
|
|
- Derrick Berry
- 5 years ago
- Views:
Transcription
1 Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers
2 75 ON 140 LC PUSH TO TRIP OFF
3 A-7. Dimensions TD & TS MCCB Index TD100/160 TS100/160/250 TS400/630 TS800 Direct rotary handles DH1 & DHK1 for TD100/160 DH2 & DHK2 for TS100/160/250 DH3 & DHK3 for TS400/630 DH4 & DHK4 for TS800 Dimension table for D-handles Extended rotary handles EH1 for TD100/160 EH2 for TS100/160/250 EH3 for TS400/630 EH4 for TS800 Dimension table for E-handles Mechanical interlocking device MIT13, MIT23, MIT33, MIT43 Mounting dimension for MIT Plug-in device Plug-in devices for TD100/160 Plug-in devices for TS100/160/250/400/630/800 Mounting to front plate Rail mounting Mounting to rear plate with cover back Mounting Terminal cover ITS and ITL Rear terminals TD100 / TD160 TS100 / TS160 / TS250 TS400 / TS630 TS800 Circuit breaker with motor operator MOP1, MOP2, MOP3, MOP4 Wiring connection Motor operator Wiring diagram(state of operation) ETS23/ETS33/ETS43 A-7-1 A-7-2 A-7-3 A-7-4 A-7-5 A-7-6 A-7-7 A-7-8 A-7-9 A-7-10 A-7-11 A-7-12 A-7-13 A-7-14 A-7-15 A-7-16 A-7-17 A-7-18 A-7-19 A-7-20 A-7-21 A-7-22 A-7-23 A-7-24 A-7-25 A-7-26 A-7-27 A-7-28 A-7-29 A-7-30 A-7-31
4 TD100/ B-23C 50 Insulation barrier M ON Mounting hole ON LC LC PUSH TO TRIP OFF 22 PUSH TO TRIP OFF Trip button B-23C , 3P 4P Terminal section Conductor Panel drilling Front panel cutting M4 or 5 M4 or 5 C L C L C L C L C L C L C L C L , 3P 4P 2, 3P 4P A-7-1
5 TS100/160/ B-23C 48 Insulation barrier C L C L C L , 3P 4P M Mounting hole ON ON 100 OFF PUSH TO TRIP OFF PUSH TO TRIP Trip button B-23C Terminal section Conductor Panel drilling Front panel cutting M4 or 5 M4 or 5 C L C L C L C L C L C L C L C L , 3P 4P 2, 3P 4P A-7-2
6 TS400/ B-33C Mounting hole LC LC LC 26.5 Trip button B-33C , 3P 4P 46.5 Terminal section Conductor 30 M10 L Panel drilling Front panel cutting C L C L M5 or 5 M5 or 5 C L C L C L C L C L C L , 3P 4P 2, 3P 4P A-7-3
7 TS B-43C Mounting hole ON ON LC LC OFF LC OFF 35 bvv PUSH TO TRIP M Trip button B-43C ,3P 4P 280 Terminal section Conductor Panel drilling Front panel cutting C L C M6 or 7 L C L C L C L C L C L C L , 3P 4P , 3P 4P A-7-4
8 Direct rotary handles DH1 & DHK1 for TD100/160 t1.2~ Panel drilling Way of installation Over 20mm 4-5 Trip Panel shaft Trip A-7-5
9 Direct rotary handles DH2 & DHK2 for TS100/160/250 t=1.2~ Panel drilling Way of installation Panner shaft Over 20mm Trip Trip A-7-6
10 Direct rotary handles DH3 & DHK3 for TS400/630 t1.2~ Panel drilling Way of installation Over 20mm 4-7 Trip Panel shaft Trip A-7-7
11 Direct rotary handles DH4 & DHK4 for TS800 t=1.2~ Panel drilling Way of installation Over 20mm 4-7 Trip Panner shaft MCCB Trip A-7-8
12 Direct rotary handles Dimension table for D-handles TD100/TS250 TS630/TS800 t1.2~3.2 E F E F B B D B D A C G G Model DH1 DH2 DH3 DH4 Applicable to TD100/160 TS100/160/250 TS400/630 TS800 A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) A-7-9
13 Extended rotary handles EH1 for TD100/160 t1.2~ Min. 163 Max. 585 (Shaft 469mm) 81 Panel drilling Way of installation OFF 47 OFF 47 A-7-10
14 Extended rotary handles EH2 for TS100/160/250 t=1.2~ Min. 163 Max. 585 (Shaft 469mm) Panel drilling Way of installation OFF 47 OFF 47 A-7-11
15 Extended rotary handles EH3 for TS400/630 t1.2~ Min. 228 Max. 645 (Shaft 469mm) 129 Panel drilling Way of installation OFF 89 OFF 89 A-7-12
16 Extended rotary handles EH4 for TS800 t=1.2~ Min. 275 Max. 687 (Shaft 469mm) Panel drilling Way of installation OFF 89 OFF 89 A-7-13
17 Extended rotary handles Dimension table for E-handles t1.2~3.2 TD100/TS250 F C TS630/TS800 F C B B E B E D A D Model EH1 EH2 EH3 EH4 Applicable to TD160 TS250 TS630 TS800 A (mm) Min. 163 Min. 163 Min. 228 Min. 275 Max. 585 Max. 585 Max. 645 Max. 687 B (mm) C (mm) D (mm) E (mm) F (mm) Shaft (mm) A-7-14
18 A Overall dimensions Mechanical interlocking device MIT13, MIT23, MIT33, MIT43 B Model Applicable to A (mm) B (mm) MIT13 TD100/ MIT23 TS100/160/ MIT33 TS400/ MIT43 TS ~8mm Dimension of lock 30mm A-7-15
19 Mechanical interlocking device Mounting dimension for MIT E D E C C 2, 3Pole MCCBs C(mm) D(mm) E(mm) TD100/ TS100/160/ TS400/ TS Pole MCCBs C(mm) D(mm) E(mm) TD100/ TS100/160/ TS400/ TS A-7-16
20 Plug-in device Plug-in devices for TD100/160 B C D A G F E TD100/160 TD100/160 A(mm) 90 B(mm) 92 C(mm) 122 D(mm) E(mm) 32.5 F(mm) 47 G(mm) 75 A-7-17
21 Plug-in device Plug-in devices for TS100/160/250/400/630/800 F G E F E TS100/160/250/400/630 TS800 TS100/160/250 TS400/630 TS800 A(mm) B(mm) C(mm) D(mm) E(mm) F(mm) G(mm) A-7-18
22 Plug-in device Mounting to front plate B A E Front plate C D Applicable to TD100/160 TS100/160/250 TS400/630 TS800 A (mm) B (mm) C (mm) D (mm) E (mm) A-7-19
23 Plug-in device Rail mounting D A B C Rail Applicable to TD100/160 TS100/160/250 TS400/630 TS800 A (mm) B (mm) C (mm) D (mm) A-7-20
24 Plug-in device Mounting to rear plate with cover back Rear plate B A C Cover back Applicable to TD100/160 TS100/160/250 TS400/630 TS800 A (mm) B (mm) C (mm) A-7-21
25 Plug-in device Mounting M A-7-22
26 Terminal cover ITS and ITL A B C(C') D(D') A C(C') B Applicable to Type Dimension(mm) Frame type TD100, TD160 TS100, TS160, TS250 TS400, TS630 TS800 Long Short C C D D Pole A B type type (Long type) (Short type) (Long type) (Short type) 2P, 3P ITL13 ITS P ITL14 ITS P, 3P ITL23 ITS P ITL24 ITS P, 3P ITL33 ITS P ITL34 ITS P, 3P ITL43 ITS P ITL44 ITS A-7-23
27 Rear terminals TD100 TD N R S T TS100 TS160 TS N R S T TS400 TS N R S T TS N R S T A-7-24
28 Rear terminals TD100 / TD160 Bar type 4P(120) Mounting plate: Max.3.2t 2,3P(90) 8.6 Round type Panel drilling Front panel cutting R2 R N R S T 4P(120) 2,3P(90) M N R S T , 3P 4P 2, 3P 4P A-7-25
29 Rear terminals TS100 / TS160 / TS250 Bar type 4P(140) 2,3P(105) Mounting plate: Max.3.2t Round type R2 R N R S T 4P(120) 2,3P(90) M N R S T Panel drilling Front panel cutting , 3P 4P 2, 3P 4P A-7-26
30 Rear terminals TS400 / TS630 Bar type 4P(186.5) 2,3P(140) Mounting plate: Max.3.2t R2 R over 52 over N R S T Panel drilling Front panel cutting , 3P 4P 2, 3P 4P A-7-27
31 Rear terminals TS800 Bar type 4P(280) 2,3P(210) Mounting plate: Max.3.2t R2 R over 52 over N R S T Panel drilling Front panel cutting , 3P 4P 2, 3P 4P A-7-28
32 Circuit breaker with motor operator MOP1, MOP2, MOP3, MOP4 TD100N/H/L TD160N/H/L Circuit breaker with MOP1 TS100N/H/L TS160N/H/L TS250N/H/L Circuit breaker with MOP TS400N/H/L TS630N/H/L Circuit breaker with MOP TS800N/H/L Circuit breaker with MOP A-7-29
33 Wiring connection Motor operator Standard connection Circuit breaker On and Off controlled by remote operation and manual operation P1 P2 S1 S2 S4 1. 2Nm Power Ue E E Connection with alarm switch (AL) 1) The below connection diagram is the method of using a alarm switch (AL) without shunt or undervoltage trip. 2) After clearing the fault surely, manual reset is mandatory in case of tripping due to an electrical fault. Connection with FAL (Circuit breakers with ETS) 1) The below connection diagram is the method of using a FAL for circuit breakers with electronic trip unit. 2) After clearing the fault surely, manual reset is mandatory in case of tripping due to an electrical fault. P1 P2 S1 S2 S4 Power Ue E ALb E ALa ALc A-7-30
34 Wiring diagram(state of operation) ETS23/ETS33/ETS43 The diagram is shown in the following conditions: Fixed version circuit-breaker (depending on type of circuit-breaker) Circuit breakers open. Releases not tripped N L1 L2 L3 N L1 L2 L3 Upstream Circuit Breaker Downstream Circuit Breaker OZ1 OZ2 IZ1 IZ2 OZ1 OZ2 IZ1 OZ2 OZ1 OZ2 IZ1 IZ2 ETS23 ETS33 ETS43 P1 G1 P2 G2 ETM33 ETM43 C1 C2 P1 + P2 - DC24V COMMUNICATION RS485 Modbus-RTU Three-pole circuit-breaker with ETS23/ETS33/ETS43 electronic release Three-pole circuit-breaker with ETM33/ETM43 electronic release (External natural current transformer) A-7-31
Low voltage circuit breakers
Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),
More informationLow voltage circuit breakers
Catalogue 2007 Super Solution Low voltage circuit breakers The Challenges and Growth achieved by LG will continue with New Will of LS Industrial Systems. New Name for LG Industrial Systems, New Take-off
More informationLow voltage circuit breakers
Catalogue 2009 Super Solution Low voltage circuit breakers The Challenges and Growth achieved by LG will continue with New Will of LS Industrial Systems. New Name for LG Industrial Systems, New Take-off
More informationLow breaking capacity moulded case circuit breakers
New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical
More informationLow voltage circuit breakers
Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Cerus TD and TS Series UL 489 Listed TD125U ln 15~125A 3.54(W) x 6.46(H) X 3.39in (D) TS250U ln150 ~ 250A 4.13 (W) x 7.01 (H) X 3.39in (D) TS400U ln 300 ~ 400A 5.51 (W) x 11.50
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More informationMOULDED CASE CIRCUIT BREAKERS 16A TO 630A
TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*
More informationACW Molded-Case Circuit Breaker UL 489 Listed
Motors Automation Energy Transmission & Distribution Coatings AC Molded-Case Circuit Breaker UL 489 Listed USA AC Overview Introducing the EG AC Series of Molded Case Circuit Breakers now available with
More informationLSIS UL MCCB & Accessory
LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12
More informationACW Molded-Case Circuit Breaker UL 489 Listed
Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.
More informationJDA. JD Auspice Co., Ltd. Catalogue
Catalogue Switch-Disconnectors TD series Frame size [AF] Conventional thermal current, Ith [A] No. of poles Rated operational voltage, AC [V] Ue Rated operational current, Ie DC [V] Rated impulse withstand
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationSiemens switchgear. Tried, tested, trusted. Circuit Breakers
* MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to
More informationNorth American Edition Super Solution Low voltage circuit breakers
www.lsis.biz North American Edition Super Solution Low voltage circuit breakers Low voltage circuit breakers Susol Low voltage circuit breakers Super Solution Contents Overview Main characteristics Accessories
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationBREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationPower protection solutions
Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationCircuit Breakers Ex9M
Circuit Breakers Ex9M Moulded Case Circuit Breakers Frame size M1 with rated current up to 125 A Frame size M2 with rated current up to 250 A 3-pole versions Rated ultimate short circuit breaking capacity
More informationIndustry Automation Control Components
Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements
More informationC1251N DC and C1251N 1000 V
T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)
More informationWORKSHOP SPECIFICATIONS
WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationUTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB
PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L
More informationMolded Case Circuit Breakers H series General information
General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationMolded case circuit breakers
Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationF.T.M.C. F.T.M.C. Motor Operator For MCCB. MCCB Accessories. Motor Operator. Part No. Frame MOPF240 FTCF F MOPJ240 F FTCJ MOPK240 FTCK
Motor Operator For MCCB Motor Operator Ref.NO. F101105 MOPF20 F101106 MOPJ20 F101107 MOPK20 F101108 MOPLG20 F101109 MOPL20 58 TYPE RHM Rotary Handle Mechanisms 59 ROTARY HANDLE MCCB Ref.No. Rotary Handle
More informationWorld Super Series WSS The extensive breaker series from Mitsubishi Electric
MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationMotor Circuit Breakers C4
Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short
More informationMITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue
Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors WSS, PSS & Super Series A 100 A Technical Catalogue 2004 Circuit Breakers Circuit Breakers The new World Super Series WSS completes the
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches MS50T3L M2N200T3L Ex9 Series - M na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationC60H-DC C curve. Catalogue numbers
distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationData Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M
Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationCurrent Sensing Resistor Metal Foil Type >SMF Series
Page: 1 of 6 General Chip size from 0603 to Resistance value from 3mΩ to 200mΩ Low thermal EMF. Low TCR. Lead free, RoHS compliant for global applications and halogen free Application Switching model power
More informationCircuit breakers for power distribution A1 Ordering information
Circuit breakers for power distribution A1 Ordering information A1 100A - Fixed (F) 1 pole - Front terminals (F) Thermomagnetic trip unit - TMF Icu (240 V) In I3 A (10kA) N (18kA) 15 400 A1A015TW-1 A1N015TW-1
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationUL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]
Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationC RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationCompact NS. Installation recommendations
Compact NS Installation recommendations Presentation 6 Functions and characteristics Operating conditions 144 Installation in switchboards 145 Power supply and weights 145 Safety clearances and minimum
More informationUnshielded Power Inductor / PI Series
.Features: 1. Excellent solderability and high heat resistance. 2. Excellent terminal strength construction. 3. Packed in embossed carrier tape and can be used by automatic mounting machine..applications:
More informationWestinghouse Molded Case Circuit Breakers Engine Generator FG Amperes
Circuit s FG 15-150 Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11 Cutler-Hammer
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More information3VT Kompaktleistungsschalter bis 630A
Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical
More informationMolded Case Circuit Breakers Solid-state trip types
Solidstate trip types Solidstate trip types, SA00E, 0E, 00E Features Equipped with a load current pretrip alarm Constantly monitors the load current, and outputs an alarm when the set current is exceeded.
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationRotary Direct Drive Motor Cartridge DDR
www.danahermotion.net Rotary Direct Drive Motor Cartridge DDR Driven by Edition 04.2004 english DDR (Direct Drive Rotary) What is direct drive? Very simply it is the direct coupling of a torque motor to
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationInnovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual
Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION
More informationEmax DC. Annex to the technical catalogue. Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications
Annex to the technical catalogue Emax DC Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications 1SDC200012D0201 Index SACE Emax DC automatic circuit-breakers...
More informationCOMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationHeat Tracing Sales Mt. Airy, Maryland Controls
Heat Tracing Line Sensing Control Panels Solid State Relay Output Rated 30 Amps or Two-Pole Contactor Control Output Universal Inputs NEMA 4/4X Enclosure Ground Fault Alarm/Trip Monitor or GFI Circuit
More information40, 50, 63, 125, , 125, , 100
DC MCCB (100~800AF) Susol MCCB is suitable for DC application such as Photovoltaic Circuit Breaker DC short circuit test tested by VDE Higher nominal voltage range up to 1000 VDC Rated Current : 16A~800A
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationEmax DC. Annex to the technical catalogue. Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications
Annex to the technical catalogue Emax DC Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications 1SDC200012D0201 Index SACE Emax DC automatic circuit-breakers...
More informationQ and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units
Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units Bul. 140U DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE ITS IS ENERGIZED.
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationSurface Mount Fuses 0603Size> Fast Acting > S0603-F Series
Page:1 of 6 General Fast Acting 1.6mm 0.8mm physical size Thick film manufacturing method, ceramic substrate, silver fusing element -50 ~125 operating temperature Excellent environmental integrity RoHS
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationSurface Mount Fuses 0603Size> Slow Blow> S0603-S-5.0A
Page: 1 of 6 General Slow Blow 1.6mm 0.8mm physical size Thick film manufacturing method, ceramic substrate, silver fusing element -50 ~125 operating temperature Excellent environmental integrity RoHS
More informationSurface Mount Fuses 0603Size> Slow Blow> S0603-S Series
Revision:F Page:1 of 6 General Slow Blow 1.6mm 0.8mm physical size Thick film manufacturing method, ceramic substrate, silver fusing element -50 ~125 operating temperature Excellent environmental integrity
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationTechnical Section: Miniature Circuit Breakers
MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationPowerPact B. Molded case circuit breakers and switches from A
PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member
More information15-I73E CAT REF.
& www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More information(p. 47) (p. 155) (p. 155)
0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More information3VF3 to 3VF8 Circuit-Breakers
3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationBULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE
BULLETIN 140U SELECTION GUIDE Product Overview Bulletin 140U 15 1200 A Thermal-Magnetic 15 800 A Electronic 70 1200 A LS Long Time/Short Time LSI Long Time/Short Time/High Instantaneous LSG Long Time/Short
More informationCompact Integrated Distribution Substation (CIDS)
Compact Integrated Distribution Substation (CIDS) 1- INTRODUCTION SAVE SPACE 2.5m 2 footprint for CIDS up to 630kVA. SAVE THE ENVIRONMENT No SF6, No PCB. SAVE MONEY Save up to 50% from conventional package
More information14-I73E CAT REF.
& www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationAccessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5
Auxiliary contacts The auxiliary contacts will signal whether the breaker is in the ON or OFF position. For field mounting: right side SC-HRU SC-HRU Bell alarm The bell alarm includes a set of contacts
More informationMemshield - ACB Ratings & Specifications
Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More information