Water Cistern. Domestic Potable Water
|
|
- Linette Reed
- 5 years ago
- Views:
Transcription
1 Standard: Cistern assemblies include tank, lid, a 2' riser & cistern filler lid, (2) 1" stainless steel female thread inserts in tank 14" apart, 2'-8" from bottom outside of tank and butyl rubber sealant. excavation should be level with no protruding rocks, and a minimum of 6" of sand or 3/4" rock bed, leveled and compacted to set tank on. Excavator should provide a safe and clear offloading site within 15' from the rear of the truck to the center of the tank. Selected (6" minus) granular backfill should be rolled in from the side in equal lifts around the tank and compacted. Avoid dumping directly on the lid of the tank. Installer should check local requirements which provide information on adapter hook up, tank placement, line locations and connections etc. A permit may be necessary for this work. Water Cistern Domestic Potable Water PLAN SECTION HEIGHT Tw 6" Threaded PVC cover Butyl rubber sealant Width Length height Tw Tf Weight Part # 1200 Gallon 5'-6" 8'-6" 8'-1" 3.5" 4" 10,485 lbs PCA Gallon 5'-6" 10'-6" 8'-1" 3.5" 4" 12,745 lbs PCA Gallon 6'-8" 10'-2" 8'-1" 4" 4" 14,455 lbs PCA Gallon 6'-8" 12'-8" 8'-1" 4" 4" 17,775 lbs PCA Gallon 6'-4" 13'-10" 8'-5" 3.5" 4" 18,230 lbs PCA Tf 1'-11" Earth cover 6" 5'-0" 30" LENGTH (2) 1" NPT stainless steel female thread inserts in one end of tank 14" apart. Plug with PVC if not required approx. frost line
2 Standard: Cistern assemblies include tank, lid, a 2' riser & cistern filler lid, (2) 1" stainless steel female thread inserts in tank 14" apart, 2'-8" from bottom outside of tank and butyl rubber sealant. excavation should be level with no protruding rocks, and a minimum of 6" of sand or 3/4" rock bed, leveled and compacted to set tank on. Excavator should provide a safe and clear offloading site within 15' from the rear of the truck to the center of the tank. Selected (6" minus) granular backfill should be rolled in from the side in equal lifts around the tank and compacted. Avoid dumping directly on the lid of the tank. Installer should check local requirements which provide information on adapter hook up, tank placement, line locations and connections etc. A permit may be necessary for this work Gal. Domestic Potable Water Cistern Total Capacity: 3680 gallons 2'-10" Four (4) 1" GR. #8 rods / isometric tension devices Two (2) 1" stainless steel female thread inserts 30" 14" 4" 24" Clear Access Opening 12'-8" 24" 10'-4" 6'-8" 5'-4" * Includes 530 lbs. for a 2x2 riser, & 175 lbs. for a 2X Cistern Lid Part # Capacity Approximate Weights (gallons) Dometite Tank Lid* Total PCA ,690 lbs 8,655 lbs 20,345 lbs
3 Fire Protection Water Storage Cistern Single Family - Precast Concrete Standard: Cistern assemblies include tank, lid, a 2' riser & cistern filler lid, (2) 1" stainless steel female thread inserts in tank 14" apart, 2'-8" from bottom outside of tank and butyl rubber sealant. excavation should be level with no protruding rocks, and a minimum of 6" of sand or 3/4" rock bed, lev-eled and compacted to set tank on. Excavator should provide a safe and clear offloading site within 15' from the rear of the truck to the center of the tank. Selected (6" minus) granular backfill should be rolled in from the side in equal lifts around the tank and compacted. Avoid dumping directly on the lid of the tank. Installer should check local requirements which provide information on adapter hook up, tank placement, line locations and connections etc. A permit may be necessary for this work. HEIGHT PLAN SECTION 6" Threaded PVC cover Butyl rubber sealant Tw 4" PVC Coupling 4" Schedule 40 PVC vent pipe with insect screen Tf True Monolithic Tank 6" Anti-vortex cut LENGTH 3'-0" 6" Cast-a-Seal Gasket 6" Male NST dry hydrant with cap 6" Schedule 40 PVC pipe Finish Grade (2) 1" NPT stainless steel female thread inserts in one end of tank 14" apart. Plug with PVC if not required 30" No joints below water line Width Length Height Tw Tf Weight Part # 1200 Gallon 5'-6" 8'-6" 8'-1" 3.5" 4" 10,470 lbs PCA Gallon 5'-6" 10'-6" 8'-1" 3.5" 4" 12,730 lbs PCA Gallon 6'-8" 10'-2" 8'-1" 4" 4" 14,440 lbs PCA Gallon 6'-8" 12'-8" 8'-1" 4" 4" 17,760 lbs PCA Gallon 6'-4" 13'-10" 8'-5" 3.5" 4" 18,215 lbs PCA
4 Standard: Cistern assemblies include tank, lid, a 2' riser & cistern filler lid, (2) 1" stainless steel female thread inserts in tank 14" apart, 2'-8" from bottom outside of tank and butyl rubber sealant. excavation should be level with no protruding rocks, and a minimum of 6" of sand or 3/4" rock bed, leveled and compacted to set tank on. Excavator should provide a safe and clear offloading site within 15' from the rear of the truck to the center of the tank. Selected (6" minus) granular backfill should be rolled in from the side in equal lifts around the tank and compacted. Avoid dumping directly on the lid of the tank Gal. Fire Protection Water Storage Cistern 6" Cast-A-Seal Gasket 2'-10" Four (4) 1" GR. #8 rods / isometric tension devices Two (2) 1" stainless steel Installer should check local female thread inserts requirements which provide information on adapter hook up, tank placement, line locations and connections etc. A permit may be necessary for this work. 30" Total Capacity: 3680 gallons 14" 4" Schedule 40 PVC coupling 4" 24" Clear Access Opening 12'-8" 6'-8" 24" See fire protection dry hydrant assembly Page 20 5'-4" 10'-4" * Includes 530 lbs. for a 2x2 riser, & 175 lbs. for a 2X Cistern Lid Part # Capacity Approximate Weights (gallons) Dometite Tank Lid* Total PCA ,690 lbs 8,640 lbs 20,330 lbs
5 Dry Hydrant Assembly for Fire Protection Cistern PLO Insect screen 6" Male NST dry hydrant with cover, strainer and chain 4" SCH 40 Vent Pipe 5' length from lid of tank to approx. 3' above grade. 4" SSH 40 tee connecting vent pipe to vent pipe in tank-to-tank system Detail at concrete lid. Primer/PVC cement ASTM D Detail at concrete lid. Rubber compression gasket ASTM C " PVC SCH 40 Sucker Pipe, variable length from anti-vortex cut at bottom to approx. 2' above grade. Dry hydrant storage tank before back-fill.
6 Three Mated 2400 Gal. Cisterns Domestic Potable Water Excavation should be 8' deep x 15' wide x 25' long. Floor of the excavation should be level with no protruding rocks, and a minimum of 4" of 3/4" rock bed, leveled and compacted to set tanks on. Excavator should provide a safe and clear offloading site within 15' from the rear of the truck to the center of the tank. Selected (6" minus) granular backfill should be rolled in from the side in equal lifts around the tank and compacted. Avoid dumping directly on the lids of the tanks. Two (2) 1" stainless steel female thread inserts PLAN Typical transfer pipe 6" SCH 40 with PSX watertight gaskets 4" Castout 4" PVC coupler for venting tank 4" PVC coupler for venting tank Other mated cistern configurations are available. Contact FRPC sales for details. 4" Castout 4" PVC coupler for venting tank 4" Castout Four mated 3600 gal. cisterns (14,400g total) for agricultural use.
Tank Wall Installation Procedure
Tank Wall Installation Procedure Preparation for Delivery 1. If the Tank Walls are dropped on site prior to installation ensure there is a flat area the tanks can be off-loaded to. 2. Ensure Tank Walls
More informationSeptic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks
Septic Tanks Gravity treatment Separation Sludge sinks Scum floats Storage Septic Tanks, Holding Tanks & Pump Tanks Bacteria SCUM breakdown CLEAR ZONE Chemical SLUDGE WW Strength= Organic Load Effluent
More informationABCD BFDC BEDA AB CDEFCC
ABCD BFDC BEDA AB CDEFCC ABCD BFDC BEDA AB CDEFCC AFC Oil/ Water Separator Specifications and Operation & Maintenance Schedule 1) Model of AFC Oil/ Water Separator: a)
More informationGB-250. Submittal Specifications Installation Application Specific Details
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 68" (1,727 mm) 13½" (343 mm) 51½" (1,308 mm) 38" (965 mm) SUBMITTAL 33½" (851 mm) STANDARD: 4" plain
More informationGB2 35/50 GPM Grease Interceptor for Indoor Use
INSTALLATION GUIDE GB2 35/50 GPM Grease for Indoor Use Contents Special Precautions.........................................2 Getting to Know the GB2....................................3 On the Floor Installation..................................
More information6 Hour Backhoe Loader (CAT 415F2/ 415F2 IL, 416F/ 416F2, 420F/420F IT, 420F2/ 420F2 IT, 430F/430F IT, 430F2/ 430F2 IT, 450F or Equiva $32.
PROJECT 2506; 2017 ANNUAL REPAIR CONTRACT; J.C. DILLON, INC., CONTRACTED SCHEDULE OF ITEMS, QUANTITIES AND COSTS 1 Hour Lowboy Including Both Permits and Paid Driver $75.00 2 Hour Single Axle Dump Truck
More informationGB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 33" (83.8 cm) 10" (25.4 cm) (63.5 cm) 15" (38.1 cm) (63.5 cm) SUBMITTAL STANDARD: 3" plain end inlet/outlet
More informationAqua Green Utility Inc.
Aqua Green Utility Inc. Individual septic tank and pump tank requirements. Only configurations and equipment approved by Aqua Green Utility Inc. may be used. Not following these configurations shall be
More informationWATER & WASTE management 2015 edition
WATER & WASTE management 2015 edition Whether you re looking for a below ground septic or cistern tank or an above ground water tank, you re sure to find it among our wide selection. Our rotational molding
More informationDomestic Traditional Pits DOMESTIC TRADITONAL PITS
Domestic Traditional Pits Ideal for use under downpipes, as a junction box, or at the end of a surfacewater drainage channels Designed for large household surfacewater drainage Australian Made from 100%
More informationDEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model 705-543 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718
More informationINSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents
INSTALLATION GUIDE Model #GB2 35/50 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB2....................................... 3
More informationGaskets. Fluid Handling Components. Bee Valve offers a full line of original and replacement gaskets to meet all your needs.
2009 Fluid Handling Components Gaskets Bee Valve offers a full line of original and replacement gaskets to meet all your needs. Bolted Tank Fitting Bulkhead Fitting Manifold System Cam Coupler Tank Lid
More informationDURISOL ANCHORED RETAINING WALL SYSTEM (DARWS)
DURISOL ANCHORED RETAINING WALL SYSTEM (DARWS) Project - DeWitt and Ridge Roads Intersection, Stoney Creek, Ontario Located on the slope of the Niagara Escarpment 11 meter wall heights with Durisol s Traffic
More informationInstallation Manual. D3600- Series Duplex Grinder Systems. Contents
Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory
More informationPERMANENT RESIDENTIAL UNDERGROUND SERVICE
CITY OF RICHLAND ENERGY SERVICES DEPARTMENT 505 Swift Boulevard, MS-21 Richland, WA 99352 Telephone (509) 942-7403 Fax (509) 942-7405 PERMANENT RESIDENTIAL UNDERGROUND SERVICE A. INTRODUCTION This guide
More informationUtilities Catalog. PC-U2008, February, 2008
Utilities Catalog PC-U2008, February, 2008 Tyler Utilities 11910 CR. 492 Tyler, Texas 75706 (800) 527-8478 Union Foundry Company Box 309 Anniston, Alabama 3602 (800) 226-7601 TABLE OF CONTENTS Item Page
More informationInstallation Manual. Q Series Quadplex Grinder Systems. Contents
Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationBall & Socket Fittings (Bauer Style)
Page 96 Ball & Socket Fittings (Bauer Style) Elbow-Bauer Style 3-1/ * *1 MM 76 89 108 133 159 194 2 300 * Locking Bar (part # 9-7318) for & 1 Lever is Sold Separately 6-9038 6-9039 6-9040 6-9041 6-9042
More informationAccess Riser Fits PRO370 and PRO380 Series
Installation Manual 7171000D Access Riser Fits PRO370 and PRO380 Series Contents 1.) General Information 2.) Installation 3.) Optional 2 Installation Kits 4.) Typical Installation Diagram 5.) Junction
More informationINSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents
INSTALLATION GUIDE Model #GB1 20/25 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB1........................................
More informationBEST MANAGEMENT PRODUCTS, INC. The SNOUT OIL-WATER-DEBRIS SEPARATOR SPECIFICATIONS U.S. Patent # Canadian Patent #
1. PRODUCT NAME The SNOUT Oil-Water-Debris Separator U. S. Patent # 6126817 Canadian Patent # 2285146 2. MANUFACTURER Best Management Products, Inc. 53 Mt. Archer Rd. Lyme CT 06371 Phone: (800) 504-8008
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS
San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance
More informationSECTIO N 15 Phone: (866) Fax: (888)
PVC FITTINGS SCHEDULE 40, 80, INSERT NYLON FITTINGS PVC & CPVC NIPPLES SECTIO N 15 www.cbsupplies.ca Phone: (866) 503-5523 Fax: (888) 562-2095 AGI@cbsupplies.ca PRODUCTS LIST SCHEDULE 40 PVC PRESSURE FITTINGS
More informationExpress Water Wagon Repair Parts
Repair Parts Express Water Wagon Repair Parts 00 Elliptical,,0 Gallon Trailer Assembly... 00 Gallon Rectangular Tank Trailer Assembly... 00 Gallon Trailer Assembly...,00 Gallon Trailer Assembly... Axles
More informationCerta-Lok, Kwik-Set and Threaded Drop Pipe
Certa-Lok, Kwik-Set and Threaded Drop Pipe Certa Lok KWIK-SET FEMALE X MALE THREADED PVC DROP PIPE U.S. Pat No. 6,666,480 7,470,383 7,261,326 7,425,024 Only products bearing the NSF Mark are Certified
More informationPatton Hill Road (Four Inch Main), Project No
Patton Hill Road (Four Inch Main), Project No. 2016100 MP-5.01 MOBILIZATION (3% MAX) 1 LS MP-5.02.8(d) 8" DIP (CLASS 350) ALL DEPTHS 600 LF MP-5.02.6(p) 6" PVC ALL DEPTHS, INCLUDING BEDDING 10 LF MP-5.02.4(p)
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS
San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance
More information$69, $63, $63, $62, Schedule B - PIP & C905 Pipe
Supplier Bid Bond Signed Proposal Form Signed Addendum #1 Subtotal (Items 1-5) Subtotal (Items 1-5) Sales tax @ 8.3% Subtotal (Items 1-56) Subtotal (Items 1-3) Subtotal (Items 1-41) 2015-2016 ELIPS Pipe
More informationCOURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson
What you will learn in this lesson IN THIS LESSON, YOU WILL LEARN... Installation steps for an AdvanTex Treatment System Important inspection points for installation inspection UNIT 4-1 Installation Steps
More informationOverfill Prevention Valve
Overfill Prevention Valve The Guardian A1100 Materials Description Body: Aluminum Floats: HDPE Seals: Viton Specifications Weight: 4.3 lbs. Diameter: 3.76 Length: 18.0 Approvals CARB ULC City of New York
More informationMain Toll Free Range Road 73, Parkland County, Alberta T0E 0S0
Main 780-727-2702 Fax 780-727-2110 Toll Free 800-661-3047 Email info@pembinaconcrete.com 53231 Range Road 73, Parkland County, Alberta T0E 0S0 For over 25 years, Pembina Concrete Products has been manufacturing
More informationService Materials. Service Materials. With Three Locations to Serve You: Avoca, NY 8125 Kanona Rd. Avoca, NY (607)
Service Materials Service Materials Rochester, NY 785 Beahan Rd. Rochester, NY 14624 (585) 436-9624 With Three Locations to Serve You: Avoca, NY 8125 Kanona Rd. Avoca, NY 14809 (607) 566-2214 Watertown,
More informationInstallation Manual. AdvanTex AX20 Treatment Systems. Residential Applications
Installation Manual AdvanTex AX20 Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com Orenco Installation Manual: AX20 Treatment Systems How To Use This Manual... Page
More information5. Underground Requirements
Un d e rg ro u n d Re q u ire me n ts Section 5 2016 Electric Service Requirements, 3rd Edition Section 5 Underground Requirements Directory Page 5.1 General 34 5.2 Conduit Requirements 34 5.3 Trench and
More informationTABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44
TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical
More informationVALVES, FIRE HYDRANTS, AND APPURTENANCES
VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)
More informationInstallation Manual. AdvanTex AX-RT Treatment Systems. Residential Applications
Installation Manual AdvanTex AX-RT Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com How To Use This Manual... Page 2 Before You Begin... Page 3 Septic Tanks Used
More information2460 / 2472 / Series Simplex Grinder Systems
Installation Manual 5651000I 2460 / 2472 / 2484 - Series Simplex Grinder Systems Features: LSG or LSGX Series 2HP Grinder Pump 24 dia. Basin available in 60, 72, or 84 depths Guide Rail System Preassembled
More informationPRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0
UNDERGROUND PRODUCTS 2018 PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338
More informationPRICE LIST UNDERGROUND PRODUCTS Greenfield Road Ayr, Ontario N0B 1E Richardson Side Road Carp, Ontario K0A 1L0
UNDERGROUND PRODUCTS 2017 PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338
More information1E0 T: F: T: F:
UNDERGROUND PRODUCTS 2018A PRICE LIST 2150 Richardson Side Road Carp, Ontario K0A 1L0 T: 1-800-267-5515 F: 613-831-2048 SalesCarp@mconproducts.com 2691 Greenfield Road Ayr, Ontario N0B 1E0 T: 1-866-537-3338
More informationSeptic tanks A septic tank from Ri-Industries offers a number of benefits: Industries
Septic tanks A septic tank from Ri-Industries offers a number of benefits: Engineer-designed and built from fine tolerance steel moulds Tanks are made from 40 MPa concrete to give additional strength and
More informationSection C. 10/2014 Web Revision 12/01/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Meter Boxes
DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10002505 Section C 10/2014 Web Revision 12/01/2017 Ford Meter Boxes Contents C-2 Ford Yokebox, Long Yokebox, Gulfbox and Crescent Box
More informationFLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL Telephone: ~ Fax:
FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL 32309-6885 Telephone: 850-668-2746 ~ Fax: 850-893-4581 Lift Station Bypass Pump & Connection Assembly Instructions Loss of power during
More informationRepair Parts Coulter Applicator Repair Parts
Repair Parts Coulter Applicator Repair Parts,000 Gallon Applicator...,000 Gallon Applicator Frame... Pump Kit...0 Injection Coulter Assembly... Knife Coulter Assembly... Tank Plumbing... Knife and Injection
More informationPRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional
1500 Gallon 2 Compartment Septic Tank 52.0 1.0 Taper Outlet and Inlet 24 O.D. with manhole cover. 4500psi @ 28 days Our septic tanks have 3 optional inlets and 1 outlet 55 from bottom of tank to bottom
More informationInstallation Manual. AdvanTex -AX20-RT Treatment Systems. Residential Applications. An illustrated guide to installing an Orenco AdvanTex
Installation Manual AdvanTex -AX20-RT Treatment Systems Residential Applications An illustrated guide to installing an Orenco AdvanTex AX20-RT Treatment System. Rev. 1.0, 1/10 Orenco Systems, Inc. Orenco
More informationBid # Plumbing Supplies RESULTS
BOARD APPROVED Bid # 15-4 - Plumbing Supplies Page 1 of 16 Grant Plumbing North Brunswick NJ PVC PIPE, SCHEDULE 40 1 1-1/4" PVC Pipe, SCH 40, 20' feet 60 $0.598 $35.88 2 1-1/2" PVC Pipe, SCH 40, 20' feet
More informationModel 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 6518FR No. 2077777(21)
More informationInstallation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth)
Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth) Table of Contents Pre- Information...................... 2................................... 3 Assembly of Components.....................
More informationSUPERSEDES ABS-C0811/AUG.
ABS-C0612/R JUNE 2012 SUPERSEDES ABS-C0811/AUG. 2011 SANITARY TEE REDUCING TEE TEE - Left Side Inlet 600007 1 1/4" 0 62852 60000 5 50 4,800 15.41 600015 1 1/2" 0 62852 60001 2 90 2,880 8.27 600023 2"
More informationProduct Manual Manuel du Produit Manual del Producto
WG Product Manual Manuel du Produit Manual del Producto PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Product Overview...Page
More informationEZ FIT SYSTEM FLEXIBLE CONNECTORS: SERVICE STATION HARDWARE
SERVICE STATION HARDWARE : EZ FIT SYSTEM By stocking just a few fittings and the right kind of FLEX-ING brand flexible connectors, you can transform your inventory into a versatile offering that s ready
More informationCerta-Lok, KWIK-SET and Threaded Drop Pipe. PVC Well Products
Certa-Lok, KWIK-SET and Threaded Drop Pipe PVC Well Products Certa Lok KWIK-SET FEMALE x MALE THREADED PVC DROP PIPE U.S. PAT NO. 6,666,480 7,470,383 7,261,326 7,425,024 SCH 80 (SCH 120 Bell) ASTM D1785
More informationSUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES
SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION 33 12 16 WATER DISTRIBUTION VALVES PART 1 GENERAL... 2 1.1 Description... 2 1.2 Reference Specifications, Codes, and
More informationSUTTON&REVENUE&SHARING&APPLICATION&FORM&2014&
SUTTON&REVENUE&SHARING&APPLICATION&FORM&2014& Project&Title:RenovationofAlpineCivicClub(SuttonCommunityHall) Contact&Name:RobertaMason,President&&Contact s&phone&#:745a1007 Contact s&email:imskool@mtaonline.net
More informationProduct Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF
WG Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Pond Volume... 2 Surface Area... 3 Streambed Construction...
More informationSCHEDULE 80 PVC PRESSURE FITTINGS L80P EFFECTIVE JULY 1, 2017 REVISED PRODUCTS PRICE LIST INCLUDES: SCHEDULE 80 PVC 1/4 TO 12
PRICE GROUP DESCRIPTION 02 SCH 80 PVC through 8 92 SCH 80 PVC 10" AND LARGER VB GASKET for FLANGE DISCOUNT MULTIPLIER PRODUCTS SCHEDULE 80 PVC PRESSURE FITTINGS INCLUDES: SCHEDULE 80 PVC 1/4 TO 12 L80P
More informationSECTION 17 FIRE HYDRANT ASSEMBLIES General
SECTION 17 FIRE HYDRANT ASSEMBLIES 17-1.01 Scope 17-1 General This section describes the requirements for furnishing and installing as appurtenances to treated water mains. These requirements include the
More informationSTAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS
STAINLESS STEEL CONDUIT SYSTEM WITH NPT THREADS SILICONE GASKETS (FDA APPROVED) SMOOTH - EASY TO CLEAN (316) STAINLESS STEEL LID STAINLESS STEEL (316) BODY PATENTED 1 Stainless Steel NPT Conduit System
More informationComposite PEX-AL-PEX Tubing
04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192
More informationPVC WELL CASING & FITTINGS 20 FT. BELL-END /8 SDR21 REDUCING COUPLINGS STEEL WELL CASING & FITTINGS
Pipe Pipe & Well Casing FT. BELL-END 0 7 293 2 2 29 27 23 " SCH0 -/2" SDR7 " SDR2 " SCH0 " SCH0 FT. BELL-END 37 32 30 29 2 " SCH0 -/2" SDR7 -/" DR27. PVC WELL CASING & FITTINGS FT. BELL-END 003 7 -/ SDR2
More informationInstallation Manual. AdvanTex AX100 Treatment Systems. Commercial Applications
Installation Manual AdvanTex AX100 Treatment Systems Commercial Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com How To Use This Manual....Page 2 Before You Begin....Page 3 Standard System Components...Page
More informationAnti Siphon Ballcock RP Anti-Siphon Ballcock
UR PS1115 Effective November 1, 2015 (SUPERCEDES PS0514 ) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. Anti Siphon Ballcock 109-603RP Anti-Siphon
More informationBasin and Package Accessories TECHNICAL BROCHURE BCBASIN FEATURES
TECHNICAL BROCHURE BCBASIN FEATURES Fiberglass Basins - heavy duty construction, standard sizes to 72" ia. and 96" eep, custom basins to 20' deep available by quote request. Covers Pipe Grommets - Use
More informationHole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole
Mechanical Tees Hole-cutting Shurjoint mechanical tees provide a fast and easy mid-point branch outlet, eliminating the need for welding or the use of multiple fittings. The Model M21 features a female
More informationMIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:
Product Catalog Table of Contents Item Page # Septic Tanks 1 Septic System Accessories 2 Frost Free Stock Tank 3 Feed Bunks 4 Storm Shelter 5 Parking Blocks 6 Pads & Blocks 7 Tiles 8 Pump Pit 9 Steps 10
More information9-43 3" 25.4 lbs. 3" 18" $ " 29.1 lbs. 4" 18" " 35.3 lbs. 5" 24" " 35.1 lbs. 6" 24"
Cast Aluminum Foot Valves Foot Valves have dresser type connection for use with O. D. tubing only. Complete assembly includes slotted strainer and safety ring and link for connection to suction tube. 9-13C...
More informationCATALOGUE SEWAGE MANHOLES
CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch
More informationExpress Hot Pressure Washer Trailer Repair Parts
Repair Parts Express Hot Pressure Washer Trailer Repair Parts Express Hot Pressure Washer Trailer... - 00 Gallon Trailer Assembly...,0 Gallon Trailer Assembly...,0 Gallon Trailer Assembly... Axles & Hubs...
More informationABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.
ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS www.bow-group.com dimension item Ctn Skid list price dimension item Ctn Skid list price SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007
More informationFoam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS
FOAM SUPPLY KITS Foam Supply Kits Elkhart offers two supply kits. Both kits include: One.75" quarter-turn, inlet valve assembly with elbow Quick-connect female coupling Quick-connect plug with chain Brushed
More informationSection One. Steel Underground. PVC Accessories Bolt-on Dresser Fittings Solvent PVC Pipe Fittings Gasketed PVC Pipe Fittings
Page Steel Underground Section One Powder Coated Steel Fittings Galvanized Steel Fittings PVC Fittings Riser Valves Clampon Saddles, Couplers, Male Ends Repair Couplers PVC Accessories Bolton Dresser Fittings
More informationHANDHOLE UNIT. WEB: PHONE: FAX:
UNIT WEB: www.concastinc.com EMAIL: info@concastinc.com PHONE: 507-732-4095 FAX: 507-732-4094 Handhole Overview TYPES OF CONCAST UNITS TRAFFIC RATED FHR, FHRSL & FHRSLP SERIES PEDESTRIAN RATED FH SERIES
More informationSDR-26 (160 PSI) SDR-21 (200 PSI) SDR-17 (250 PSI) MINIMUM WALL (IN.) 20 LENGTH. 1.5" 1.900" N/A N/A N/A.090" ".419 lbs..415 lbs.
u ASTM D2241 PRESSURE PIPE Gasketed Pipe Specifications Northern Pipe Products ASTM D2241 IPS Pressure Rated Pipe is manufactured from compounds conforming to cell class 12454 in accordance with ASTM D1784.
More informationPVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY
For the most up-to-date version of this price list, EFFECTIVE MARCH 4, 2019 ENGINEERED FOR DURABILITY HARRINGTON CORPORATION P.O. BOX 10335 LYNCHBURG, VIRGINIA 24506-0335 For the most up-to-date version
More informationFACILITY WATER DISTRIBUTION PIPING
SECTION 221113 - FACILITY WATER DISTRIBUTION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUTILITY CROSSING DETAIL
6" OF CSBC COMPACTED TO A FIRM AND UNYIELDING CONDITION. NOTE: - SILT FENCE SHALL CONFORM TO 8-01.3(9)A - SILT FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE. - POST SPACING MAY BE INCREASED
More informationMATERIAL SPECIFICATIONS AND BID PROPOSAL SHEET
CATEGORY 1: STEEL COUPLINGS 0 ¾" Steel Couplings (Smith-Blair #411-0501-003) 20 1" Steel Couplings (Smith-Blair #411-013201-003) 20 1¼" Steel Couplings (Smith-Blair #411-016601-003) 20 2" Steel Couplings
More informationDUCTILE IRON PIPE DESIGN
4"-64" FOR FIRE ROTECTION, WATER & WASTEWATER 866.DI.IE 2 Table of Contents Ductile Iron ipe 3 Laying Conditions 5 Design Method and Examples of Selection Method 6 ressure Class 10 Thickness Class 11 Earth
More informationSPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationCONTAINER GUIDE WELDMENTS
CONTAINER GUIDE WELDMENTS FOR MODELS - ALL FRONT LOAD CONTAINERS 4/98 1 9110--39--0 L.H. Container Guide Weldment 1 2 9110--38--0 R.H. Container Guide Weldment 1 3 9110--56--1 Instruction Sheet (Not Shown)
More informationSection 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings
Section 2 Cast & Wrought Grooved Fittings Shurjoint Grooved Fittings... 56 Flow Data / Friction Resistance... 56 Ductile Iron Grooved Fittings 7110 / 7111 / 7112 / 7113 Elbows... 57 7120 / 7135 / 7130
More informationNON RETURN BRASS FLANGED AGA GAS APPROVED
NON RETURN BRASS FLANGED AGA GAS APPROVED ACTUATED MARINE STAINLESS STEEL 34 VALVES 36... BRASS BALL VALVES 37... AGA GAS APPROVED VALVES GATE VALVES 38... BRASS VALVES 39... RUBBER BELLOW, HOSECOCKS &
More informationJ 05/15 FIBERGLASS STORAGE TANK INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES
FIBERGLASS STORAGE TANK INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES PETROLEUM TANKS FLOWTITE WATER TANKS OIL / WATER SEPARATORS CHEMICAL TANKS VERSION J 05/15 FIBERGLASS TANK INSTALLATION INSTRUCTIONS
More informationWSB clean: Installation Manual
WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4
More informationGREASE INTERCEPTOR REQUIREMENTS
CALAVERAS COUNTY WATER DISTRICT GREASE INTERCEPTOR REQUIREMENTS HANDOUT 05 Calaveras County Water District Water and Sewer Building Service Standards GREASE INTERCEPTOR REQUIREMENTS GENERAL The following
More informationMODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO.
9-0688 MODEL NO. 00-800 & UP MODEL NO. 0-800 & UP MODEL NO. 5-800 & UP MODEL NO. -800 & UP MODEL NO. 0-800 & UP SKID SPRAYER with the Diaphragm Pump FORM NO. 95-90 SET-UP AND PARTS CATALOG SAFETY AND INSTRUCTION
More informationTECHNICAL DATA. Trimpac 244a. April 15, 2011
April 15, 2011 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally required
More informationPROJECT: : Maysak New House Construction_Weno, Chuuk State DATE : 27 June 2016 ORDER : 23 SETS (Complete with Electrical) of the below Items
PROJECT: : Maysak New House Construction_Weno, Chuuk State DATE : 27 June 2016 ORDER : 23 SETS (Complete with Electrical) of the below Items ITEM # QUANTITY UNIT DESCRIPTION A. LUMBER - all wood to be
More informationUsed Oil Drain Used Antifreeze Drain
Roughneck II Series Self Evacuating Drains Drain used oil or antifreeze into the 23 gallon reservoir, then connect to low pressure air hose to evacuate oil or antifreeze into any bulk storage tank. No
More informationPressure Pipes & Fittings
Pressure Pipes & Fittings Description: UPVC and CPVC pipes for hot and cold water supply under pressure. Range: Metric series fromø16 up toø315 mm, Imperial series fromø1/2" up toø1". Pressure Rating:
More informationMODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP
MODEL NO. -900 & UP MODEL NO. 00-900 & UP MODEL NO. 0-900 & UP MODEL NO. 0-900 & UP SKID SPRAYER FORM NO. 99-055 REV. B SET-UP AND PARTS LIST Refer to the illustrated Parts List for the details of parts
More informationType 2 Push-Through 37 Ton Log Splitter. Assembly Manual
Type 2 Push-Through 37 Ton Log Splitter Assembly Manual Refer to this manual for the following models: RS37PT-LF09PC-16-1 RS37PT-LF09EC-16-1 RS37PT-LF09EC-16-2 RS37PT-LF13EC-22-1 RS37PT-LF13EC-22-2 RS37PT-LF15EC-22-1
More informationV4PS. Installation, Operation, & Maintenance Manual
V4PS Installation, Operation, & Maintenance Manual BEFORE GETTING STARTED The following symbols will appear throughout these installation, operation and maintenance instructions for your benefit and to
More informationBALL VALVES. Industry-Leading 300psi Low Lead Ball Valves
BALL VALVES Industry-Leading 300psi Low Lead Ball Valves Designed and Manufactured to Meet Your Needs 1 Lockwing Accepts bullet lock (when equipped on meter valve). 2 Stainless steel reinforced seat gaskets
More informationCarter Hydrant Pit Valve 4th Edition EI 1584 Model 60554
Carter Hydrant Pit Valve 4th Edition EI 1584 Model 60554 Eaton s Carter Model 60554 Hydrant Pit Valve is a family of valves that includes lanyard, air or dual air/lanyard operated pilot valves, with available
More informationMODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO.
9-0688 MODEL NO. 00-800 & UP MODEL NO. 0-800 & UP MODEL NO. 5-800 & UP MODEL NO. -800 & UP MODEL NO. 0-800 & UP SKID SPRAYER with the Centrifugal Pump FORM NO. 95-9095 SET-UP AND PARTS CATALOG SAFETY AND
More information