Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

Size: px
Start display at page:

Download "Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks"

Transcription

1 Septic Tanks Gravity treatment Separation Sludge sinks Scum floats Storage Septic Tanks, Holding Tanks & Pump Tanks Bacteria SCUM breakdown CLEAR ZONE Chemical SLUDGE WW Strength= Organic Load Effluent Screen Cleaning Effluent Screens Screen must be accessible Screen is washed off at the inlet end of the tank to protect against cleanings flowing directly out the outlet Some units have protection against outflow Surveying Abbreviations Installation Keys Level Bottom BM: Benchmark An established point with a permanent elevation [Set elevation] Elevation In & Out Dealing with material BS: Backsight (or TBM) Shifted bench mark (Temporary Benchmark) RR: Rod Reading Elevation reading [Today] HI: Height of Instrument The BM elevation + the Rod Reading on the BM *

2 The Math Elevations Grade rod HI= Height of Instrument {HI} = [BM elv] + RRBM = Bottom elevation = Plan Depth Bedding 100 = BM Existing Grade Tank 96 Outlet per Plan = 90.5 Bottom Rod setting = HI Bottom elevation = 16.7 Tank bottom Bedding = 6 (0.5 ) What s the rod reading for the bottom of the excavation? Being Safe is Important Accidents: Why do they happen? Rushing Eyes not on path Eyes not on Task Line of fire Cell Phone Site Safety Spoil Pile Vests Hard hats OSHA Competent Person At least 2 feet back from the edge of trench.

3 OSHA Soil Terms Cohesive Clay Sticks together Granular Sand Flows out of the bucket Soil Identification Solid Rock Type A (not Fill) Cohesive > 1.5 tsf Type B Not an A or C Type C Cohesive < 0.5 tsf Granular Water Visual Testing Manual Testing Soil Penetrometer Area Reading Locates Local One Call Soil sample Flat surface Size of a softball Excavation Soil Faces Safety Requirements Exits Within 25 Ladders [3 ] Protection Systems Shoring Trench boxes Sloping Push to red line Reading Tons per Foot2 [TSF] Sloping 7.5 Class A ¾:1 Class B 1:1 Class C 1.5: tank bottom

4 Calculating Tank Capacity Tank INSIDE dimensions Operating depth is measured to the INVERT of the OUTLET REMEMBER: 1 = Ft, 1 cubic foot = 7.5 gallons Volume = Length X Width X Depth 4 x 7 x 60 /12 /ft = 140 cubic ft (ft3) 140 ft3 X 7.5 gallons/ft3 = 1050 gallons Materials Concrete Plastic Fiberglass Metal * Compartments Concrete Thoughts Single Small Dosing Tanks First tanks in series Weight Two Typical Septic tanks Watertightness Three For dosing from 3rd Comp Delivery of the Tank Delivery Placement Construction Poured in place Separation from saturated soil Concrete Tanks How? Additional work Can determine the tank material choice Top seam Mid-seam

5 Tank Seams Good Seams Integrated [Notched] Mastic material Mechanical connection Sealing Concrete Tank Seams Joint made at point of manufacture Butyl rubber band applied prior to installation Watertightness Testing Water balance Fill above the seams into the manhole Set for 24 hours Come back Refill 4 hour drop < 1 Hydrostatic test Standard C 1227, ASTM (1993) Vacuum Preparation Pass/fail criterion Seal tank, fill with water, and let stand for 24 hours. Refill tank. Approved if water level is held for 1 hour Seal tank, fill with water, and let stand for 8 to 10 hours. Refill tank and let stand for another 8 to 10 hours. Approved if no further measurable water level drop occurs Vacuum Test 4 hg for 5 minutes NPCA (1998) Preparation Pass/fail criterion Seal tank and apply a vacuum of 2 in. Hg. Approved if 90% of vacuum is held for 2 minutes. Seal tank and apply a vaccum of 4 in. Hg. Hold vacuum for 5 minutes. Bring vacuum back to 4 in. Hg. Approved if vacuum can be held for 5 minutes without a loss of vacuum. Vacuum Testing Vacuum pump Pipe seal Plate seal to top of riser or tank Gauge to measure vacuum

6 Risers & Other Penetrations Plastic Tank Thoughts Strength Backfilling & Bedding Material Water Watertightness Be careful of vacuum Compartment Walls Granular Backfill Lids with Screws How do I keep the screws from stripping?? 1. Start all screws thru lid into riser holes 2. Tighten all screws finger tight in star pattern 3. Finish tightening with hex wrench in star pattern Star Pattern

7 Burying Tanks Proper Backfill Backfilling Around Tanks Tied into Soil Fill with Water as Backfilling * Backfilling Around Tanks Backfilling Around Tanks 5th lift of backfill Setting tank on bedding 2nd lift of backfill 7th lift of backfill Pipe Bedding, Inlet & Outlet Pipe Installation Installing Risers 3rd lift of backfill First lift of backfill 4th lift of backfill Compaction Backfilling Around Tanks Final lift of backfill, Compaction & Grading 6th lift of backfill Backfilling Round Tanks Plastic or Fiberglass Tanks Properly backfilled tank excavation with compacted backfill & pipe bedding Compaction Force Bedding Movement Bellies in inlet & outlet pipes due to settling of supporting backfill Force Vector

8 Tanks w/ Granular Backfill ATU Basics Tank Air Source Distribution Return Access Floating Tanks Floating Tanks Properly Ballasted S T Buoyancy= B Vol. x 8.34 #/gal Times Safety factor [1.5] Restraining Force= Weight of soil [80 #/cuft]= S Weight of tank= T B Metal: Run & Hide! The Math Buoyancy from groundwater (B) = S 1,500 gal x 8.34 #/gal 12,510 # X 1.5 (safety factor) 18,765 # T B Force Down= Weight of Soil (S): 4 x 7 x 1.5 x 80 #/cuft = 3,360 # Total (S+T) = 3360# # =12,560# Plastic = 3360# + 500#= 3860#

9 Placing the Tank Access Requirements Proper elevation In Out 20 inch manhole Level bottom Within 6 of each edge Bedding Each compartment Tank Label Name, Model, Capacity Warning label Backfill Material Compaction Settling Keeping the Tank Safe Insulation [Cold Weather] 24 of Soil 1 of Insulation*= 12 of soil Always a plus Manholes *Closed cell, high density foam insulation At the surface for management Keeping the Tank Safe Tank & Riser Insulated Insulboard does not have to be tight against riser Fill space between riser and isulboard with soil

10 Holding Tanks Tank Materials Concrete Plastic Anchoring system Slide 44 Watertightness Access Requirements Critical 6 pump out stack Be EXTRA Protect from run off careful Sealing cement Siphon Discharge Siphon Discharge Required in some counties Alternate dosing device to pump Must have grade to use Alarm a Good Idea Usually installed by tank manufacturer Various sizes available Can be screened Must be primed before use Can be in 2nd or 3rd compartment

11 Siphon Discharge Demo Dual siphons in tank Note exit height 2 Discharge Pipe To 1.5 Laterals Siphon Discharge Demo 1.5 Sched 40 PVC Four 50 laterals 5/32 24 OC Squirt Ht= Pump Tanks Wiring Proper size Be careful of the power Watertight Combo Tanks Wall must be designed Hard conduit around the tank to handle the weight Sizing must be adequate Tank Abandonment Questions?

COURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson

COURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson What you will learn in this lesson IN THIS LESSON, YOU WILL LEARN... Installation steps for an AdvanTex Treatment System Important inspection points for installation inspection UNIT 4-1 Installation Steps

More information

Installation Manual. AdvanTex AX-RT Treatment Systems. Residential Applications

Installation Manual. AdvanTex AX-RT Treatment Systems. Residential Applications Installation Manual AdvanTex AX-RT Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com How To Use This Manual... Page 2 Before You Begin... Page 3 Septic Tanks Used

More information

WSB clean: Installation Manual

WSB clean: Installation Manual WSB clean: Installation Manual Models: WSB 400 WSB 1250 WSB 500 WSB 1500 WSB 600 WSB 1600 WSB 750 WSB 1800 WSB 1000 TABLE OF CONTENTS 1 INTRODUCTION...3 2 SAFETY INFORMATION...3 3 WSB CLEAN SYSTEM OPERATION...4

More information

ABCD BFDC BEDA AB CDEFCC

ABCD BFDC BEDA AB CDEFCC ABCD BFDC BEDA AB CDEFCC ABCD BFDC BEDA AB CDEFCC AFC Oil/ Water Separator Specifications and Operation & Maintenance Schedule 1) Model of AFC Oil/ Water Separator: a)

More information

Pressure Distribution. Western Canada Onsite Wastewater Management Association

Pressure Distribution. Western Canada Onsite Wastewater Management Association Pressure Distribution EFFLUENT DISTRIBUTION Get even distribution Space the doses Layout the distribution system Make choices for: piping, orifices, volumes Use worksheets for calculations Dose or flush

More information

Installation Manual. AdvanTex AX20 Treatment Systems. Residential Applications

Installation Manual. AdvanTex AX20 Treatment Systems. Residential Applications Installation Manual AdvanTex AX20 Treatment Systems Residential Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com Orenco Installation Manual: AX20 Treatment Systems How To Use This Manual... Page

More information

Aqua Green Utility Inc.

Aqua Green Utility Inc. Aqua Green Utility Inc. Individual septic tank and pump tank requirements. Only configurations and equipment approved by Aqua Green Utility Inc. may be used. Not following these configurations shall be

More information

Build-A-Box Modular Trench Shielding System

Build-A-Box Modular Trench Shielding System AMERICA S TRENCH BOX BUILDER Build-A-Box Modular Trench Shielding System EFFICIENCY PRODUCTION Build-A-Box Tabulated Data Tabulated Data Effective January 4, 2010 Revised: January 4, 2018 - with CHANGE

More information

Build-A-Box. Modular Trench Shielding System. Tabulated Data Effective January 4, Revised: April 21, with CHANGE THREE

Build-A-Box. Modular Trench Shielding System. Tabulated Data Effective January 4, Revised: April 21, with CHANGE THREE Build-A-Box AMERICA S TRENCH BOX BUILDER Modular Trench Shielding System EFFICIENCY PRODUCTION, INC. Build-A-Box Tabulated Data Tabulated Data Effective January 4, 2010 Revised: April 21, 2015 - with CHANGE

More information

Installation Manual. AdvanTex -AX20-RT Treatment Systems. Residential Applications. An illustrated guide to installing an Orenco AdvanTex

Installation Manual. AdvanTex -AX20-RT Treatment Systems. Residential Applications. An illustrated guide to installing an Orenco AdvanTex Installation Manual AdvanTex -AX20-RT Treatment Systems Residential Applications An illustrated guide to installing an Orenco AdvanTex AX20-RT Treatment System. Rev. 1.0, 1/10 Orenco Systems, Inc. Orenco

More information

Water Cistern. Domestic Potable Water

Water Cistern. Domestic Potable Water Standard: Cistern assemblies include tank, lid, a 2' riser & cistern filler lid, (2) 1" stainless steel female thread inserts in tank 14" apart, 2'-8" from bottom outside of tank and butyl rubber sealant.

More information

Water Connection Repair Method and Techniques

Water Connection Repair Method and Techniques Water Connection Repair Method and Techniques LINE LOCATES APWA Colour Codes Representatives from utility companies can field locate their lines if required. Excavation Ensure excavation is on the opposite

More information

GREASE INTERCEPTOR REQUIREMENTS

GREASE INTERCEPTOR REQUIREMENTS CALAVERAS COUNTY WATER DISTRICT GREASE INTERCEPTOR REQUIREMENTS HANDOUT 05 Calaveras County Water District Water and Sewer Building Service Standards GREASE INTERCEPTOR REQUIREMENTS GENERAL The following

More information

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches. PUMP TYPES Sump Clean Water Only Systems that need a Lift Effluent Multi stage Single stage Sewage Grinder Pumping to Gravity Distribution When STA is at higher elevation than septic tank Pump Sizing TDH

More information

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version SEPTIC TANKS Round septic tanks Standard version ECO version Rectangular septic tanks Standard version ECO version Reinforced vertical septic tanks Reinforced horizontal septic tanks Grease traps for private

More information

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS Washtenaw County Department of Planning & Environment Development Services Division DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS 705 N. Zeeb Road Phone: (734) 222-3800

More information

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines 000535 GL0098P Beta+ Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: 028 3025 4077 IRL: 048 3025 4077 Enclosed Documents DS1151P Beta+

More information

HYDROCARBON SEPARATORS

HYDROCARBON SEPARATORS HYDROCARBON SEPARATORS Hydrocarbon separators class I in PE Standard version (to install in consolidated sand) Reinforced version (to install in sand) Without and with mud trap Hydrocarbon separators class

More information

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional 1500 Gallon 2 Compartment Septic Tank 52.0 1.0 Taper Outlet and Inlet 24 O.D. with manhole cover. 4500psi @ 28 days Our septic tanks have 3 optional inlets and 1 outlet 55 from bottom of tank to bottom

More information

2460 / 2472 / Series Simplex Grinder Systems

2460 / 2472 / Series Simplex Grinder Systems Installation Manual 5651000I 2460 / 2472 / 2484 - Series Simplex Grinder Systems Features: LSG or LSGX Series 2HP Grinder Pump 24 dia. Basin available in 60, 72, or 84 depths Guide Rail System Preassembled

More information

GB-250. Submittal Specifications Installation Application Specific Details

GB-250. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 68" (1,727 mm) 13½" (343 mm) 51½" (1,308 mm) 38" (965 mm) SUBMITTAL 33½" (851 mm) STANDARD: 4" plain

More information

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed

More information

Installation Manual. AdvanTex AX100 Treatment Systems. Commercial Applications

Installation Manual. AdvanTex AX100 Treatment Systems. Commercial Applications Installation Manual AdvanTex AX100 Treatment Systems Commercial Applications 1-800-348-9843 +1-541-459-4449 www.orenco.com How To Use This Manual....Page 2 Before You Begin....Page 3 Standard System Components...Page

More information

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Installation Manual. D3600- Series Duplex Grinder Systems. Contents Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory

More information

E-Z Treat Installation Guidelines

E-Z Treat Installation Guidelines E-Z Treat Installation Guidelines E-Z Treat Company or its representative will conduct on-site training with each installer before they are certified to install E-Z Treat systems. The training will include

More information

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report These instructions are for homeowners and inspectors completing the onsite wastewater treatment system

More information

Marathon 205 North St. Marathon, WI toll free (800) Gallon Septic Tank (Low Profile, 3-inch Floor)

Marathon 205 North St. Marathon, WI toll free (800) Gallon Septic Tank (Low Profile, 3-inch Floor) Drawing #: CM-ST-650 Septic Tank Table of Contents Section A: Drawing #: CM-ST-650 CM-ST-750 CM-ST-1000 CM-ST-1000-LP CM-ST-1250 CM-ST-1650 CM-ST-1650-2COMP CM-ST-2COMP-5FL CM-HT-2000-W CM-ST-2000 CM-ST-2000-W

More information

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO: GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 33" (83.8 cm) 10" (25.4 cm) (63.5 cm) 15" (38.1 cm) (63.5 cm) SUBMITTAL STANDARD: 3" plain end inlet/outlet

More information

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638 SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638 SaniTEE Manual Bio-Microbics, Inc. Revised December 2009. SaniTEE is a registered

More information

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION

County of Yolo UNDERGROUND STORAGE TANK PROGRAM INSTALLATION/MODIFICATION/REPAIR APPLICATION April Meneghetti, REHS Environmental Health Divison Manager County of Yolo DEPARTMENT OF COMMUNITY SERVICES Environmental Health Division 292 West Beamer St., Woodland, CA 95695 PHONE - (530) 666-8646

More information

GAMMA Septic Tanks Installation & Operation Guidelines

GAMMA Septic Tanks Installation & Operation Guidelines 017906 GAMMA Septic Tanks Installation & Operation Guidelines Kingspan Environmental Service Contact Numbers: UK: 0844 846 0500 NI: +44 283025 4077 IRL: +44 283025 4077 NOR : +47 22 021 920 Enclosed Documents

More information

5. Underground Requirements

5. Underground Requirements Un d e rg ro u n d Re q u ire me n ts Section 5 2016 Electric Service Requirements, 3rd Edition Section 5 Underground Requirements Directory Page 5.1 General 34 5.2 Conduit Requirements 34 5.3 Trench and

More information

Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF

Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF WG Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Pond Volume... 2 Surface Area... 3 Streambed Construction...

More information

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design Design Manual Chapter 9 - Utilities 9B - Trench Design 9B-5 Depth of Bury Tables A. General The depth of bury tables on the following pages are based upon the design methodology from the various pipe material

More information

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:

More information

This publication is copyrighted and intended for the sole use of General Industries - 07/07/2016

This publication is copyrighted and intended for the sole use of General Industries - 07/07/2016 AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures

More information

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac Minimum Specifications/Questionnaire Bid Results for One (1) New Fuel Dispensing System-Larrabee Shop Winning Bid PERMIT FEES, FORMS, PLANS and NOTIFICATIONS Secure all necessary state and local permits

More information

Table of Contents. Introduction. Off-loading/ Unpacking Instructions. Installation Instructions. OPS (Operations/Control Center) Installation

Table of Contents. Introduction. Off-loading/ Unpacking Instructions. Installation Instructions. OPS (Operations/Control Center) Installation Table of Contents Introduction Off-loading/ Unpacking Instructions Installation Instructions OPS (Operations/Control Center) Installation Teflon Diffuser Assembly Inspection Hydro-Action Air Pump OPS Controls

More information

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

PERMANENT RESIDENTIAL UNDERGROUND SERVICE CITY OF RICHLAND ENERGY SERVICES DEPARTMENT 505 Swift Boulevard, MS-21 Richland, WA 99352 Telephone (509) 942-7403 Fax (509) 942-7405 PERMANENT RESIDENTIAL UNDERGROUND SERVICE A. INTRODUCTION This guide

More information

Bhagawati International Limited

Bhagawati International Limited Bhagawati International Limited Septic Tank Advantages of FRP Septic tank: Advantage #1 You will not need to dig as large a hole for a fiberglass septic tank as you will for a concrete septic tank. A fiberglass

More information

Main Toll Free Range Road 73, Parkland County, Alberta T0E 0S0

Main Toll Free Range Road 73, Parkland County, Alberta T0E 0S0 Main 780-727-2702 Fax 780-727-2110 Toll Free 800-661-3047 Email info@pembinaconcrete.com 53231 Range Road 73, Parkland County, Alberta T0E 0S0 For over 25 years, Pembina Concrete Products has been manufacturing

More information

New UST Installation Inspection Checklist

New UST Installation Inspection Checklist Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection

More information

Pressure Distribution Design

Pressure Distribution Design 1 Pressure Distribution Design 2 Let s Start with Nonpressurized systems Historically the norm 3 Distribution Systems 4 Distribution Systems Non-pressurized Distribution Non-pressurized Distribution (cont.)

More information

Flood Dosed System Worksheet

Flood Dosed System Worksheet Number of bedrooms Flood Dosed System Worksheet Septic tank size Minimum 1000 gallons Dosing tank size Minimum 800 gallons or 1 bedroom smaller than septic tank size whichever is larger Filter: gravity(in

More information

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District Last Updated on October 27, 2011 Grease interceptors are required to separate out Fats, Oils and Greases (FOGs) and solids normally found in food preparation waste from the rest of the wastewater being

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS EARTHSAFE D10 WASTEWATER TREATMENT SYSTEM A. PREPARING THE SITE INSTALLATION SUGGESTIONS See if you can site the tanks away from commonly used vehicular access, and also away

More information

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax: Product Catalog Table of Contents Item Page # Septic Tanks 1 Septic System Accessories 2 Frost Free Stock Tank 3 Feed Bunks 4 Storm Shelter 5 Parking Blocks 6 Pads & Blocks 7 Tiles 8 Pump Pit 9 Steps 10

More information

AMERICAN RECIRCULATING SAND FILTER SYSTEMS

AMERICAN RECIRCULATING SAND FILTER SYSTEMS American Manufacturing Company, Inc. P.O. Box 549, Manassas, VA 20108 1-800-345-3132 AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING DESIGN GUIDELINES FOR COMMUNITY AND COMMERCIAL SIZED TREATMENT

More information

2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity

2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity 2010iP Simplex Typical Installation Instructions Simplex Station 700 L Capacity Rev. 1 The 2010iP Simplex station is a well-engineered system designed to provide low-pressure sewer service to individual

More information

6 Hour Backhoe Loader (CAT 415F2/ 415F2 IL, 416F/ 416F2, 420F/420F IT, 420F2/ 420F2 IT, 430F/430F IT, 430F2/ 430F2 IT, 450F or Equiva $32.

6 Hour Backhoe Loader (CAT 415F2/ 415F2 IL, 416F/ 416F2, 420F/420F IT, 420F2/ 420F2 IT, 430F/430F IT, 430F2/ 430F2 IT, 450F or Equiva $32. PROJECT 2506; 2017 ANNUAL REPAIR CONTRACT; J.C. DILLON, INC., CONTRACTED SCHEDULE OF ITEMS, QUANTITIES AND COSTS 1 Hour Lowboy Including Both Permits and Paid Driver $75.00 2 Hour Single Axle Dump Truck

More information

UTILITY CROSSING DETAIL

UTILITY CROSSING DETAIL 6" OF CSBC COMPACTED TO A FIRM AND UNYIELDING CONDITION. NOTE: - SILT FENCE SHALL CONFORM TO 8-01.3(9)A - SILT FENCES SHALL BE INSTALLED ALONG CONTOUR WHENEVER POSSIBLE. - POST SPACING MAY BE INCREASED

More information

EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. *

EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. * EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. * INTRODUCTION Experience with onsite systems has proven that equal application of wastewater over the entire soil

More information

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED Installation Guide Hydro Zones Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED In planning for the installation of a new Hydro Zone, there are many important considerations that must be evaluated

More information

W-SERIES TYPICAL INSTALLATION INSTRUCTIONS & WARRANTY INFORMATION SIMPLEX, DUPLEX, TRIPLEX & QUADPLEX STATIONS

W-SERIES TYPICAL INSTALLATION INSTRUCTIONS & WARRANTY INFORMATION SIMPLEX, DUPLEX, TRIPLEX & QUADPLEX STATIONS W-SERIES TYPICAL INSTALLATION INSTRUCTIONS & WARRANTY INFORMATION SIMPLEX, DUPLEX, TRIPLEX & QUADPLEX STATIONS 1 Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene

More information

Installation - Tank & Aerator

Installation - Tank & Aerator Installation - Tank & Aerator 1500 SERIES MEDIA PLANTS & ALL OTHER MODELS NSF LISTED & 1500 S SERIES PLANTS These instructions apply to J-1500 Series and 1500 S Series plants. Each series has a 500, 750,

More information

Worksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007

Worksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007 Job: Date: Designer: Design number: Option number: Worksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007 This is an iterative process, so each step might

More information

Using the Weigh Wagon

Using the Weigh Wagon Using the Weigh Wagon This document does not purport to address all of the hazards. Individuals are responsible for obtaining full safety and hazard training prior to attempting this procedure. Summary

More information

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE DEFENDER SERIES 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model 705-543 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718

More information

BioSTEP Screened Pumping System Installation & Service Manual

BioSTEP Screened Pumping System Installation & Service Manual BioSTEP Screened Pumping System Installation & Service Manual FOR USE WITH BioSTEP 1618 BioSTEP Manual Bio-Microbics, Inc. Revised June 2013. BioSTEP is a registered trademark owned by Bio-Microbics, Inc.

More information

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 6518FR No. 2077777(21)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR B409 DOUBLEWALL TANK SUMP WITH REINFORCED BOTTOM Use this manual for the B-830-D-AB series transition containment sumps ii-b409-dw-12a WWW.SBRAVO.COM 800-AT-BRAVO The B-409

More information

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649

More information

How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1

How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 Seth Johnson How to build a Hydraulic Ram Pump By Seth Johnson Land To House Version 1.1 History: A man named John Whitehurst first created the Hydraulic Ram Pump in 1772. That means that this ingenious

More information

The McCandless Township Sanitary Authority. Fats, Oils and Grease (FOG) Control Device. Design Guidance

The McCandless Township Sanitary Authority. Fats, Oils and Grease (FOG) Control Device. Design Guidance The McCandless Township Sanitary Authority Fats, Oils and Grease (FOG) Control Device Design Guidance These guidelines are based upon the standards published by the Plumbing and Drainage Institute (PDI).

More information

Tank Wall Installation Procedure

Tank Wall Installation Procedure Tank Wall Installation Procedure Preparation for Delivery 1. If the Tank Walls are dropped on site prior to installation ensure there is a flat area the tanks can be off-loaded to. 2. Ensure Tank Walls

More information

J 05/15 FIBERGLASS STORAGE TANK INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES

J 05/15 FIBERGLASS STORAGE TANK INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES FIBERGLASS STORAGE TANK INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES PETROLEUM TANKS FLOWTITE WATER TANKS OIL / WATER SEPARATORS CHEMICAL TANKS VERSION J 05/15 FIBERGLASS TANK INSTALLATION INSTRUCTIONS

More information

H o l l o w S t e m A u g e r E q u i p m e n t

H o l l o w S t e m A u g e r E q u i p m e n t H o l l o w S t e m A u g e r E q u i p m e n t Pitcher Drilling s hollow stem auger rigs are used to collect soil samples and to construct/destruct monitoring or recovery wells. TRUCK AND TRACK MOUNTED

More information

V4PS. Installation, Operation, & Maintenance Manual

V4PS. Installation, Operation, & Maintenance Manual V4PS Installation, Operation, & Maintenance Manual BEFORE GETTING STARTED The following symbols will appear throughout these installation, operation and maintenance instructions for your benefit and to

More information

Sequencing Batch Reactor. Reference Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245

Sequencing Batch Reactor. Reference Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245 Sequencing Batch Reactor Reference Manual Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245 2017 Anua 12-2017 Table of Contents 1.0 What s in the Box?

More information

The Pump Matic Range

The Pump Matic Range The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality

More information

Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D November 21, 2013

Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D November 21, 2013 Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D4-1102 November 21, 2013 Doughtie Construction Co., Elliott Construction Dudley Construction Ltd. SUBTOTAL GENERAL ITEMS : $191,713.00

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES SUMP TANKS INSTALLATION GUIDELINES Thank you for purchasing a quality SumpTank. In order to gain the maximum benefit from your purchase, we have outlined the following instructions for the installation

More information

SAN ANTONIO WATER SYSTEM

SAN ANTONIO WATER SYSTEM SAN ANTONIO WATER SYSTEM SAWS WATER JOB NO. 17-5026 2017 SMP MERRY ANN DR. FROM FRANCES JEAN TO DEAD END G:\TXC\Projects\SAWS\SAWS - Merry Ann\03_CADD\01_Sheets\Merry Ann_Water\01_Sheets\1 MANN WATR CVR.dwg

More information

PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001

PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001 PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001 State of Wisconsin Department of Commerce Division of Safety and Buildings SBD-10706-P

More information

OIL/WATER SEPARATORS LIST PRICE 01/18 EFFECTIVE: JANUARY 1, 2018 PUBLICATION NO. PG 11015H SUPERSEDES PG 11015G

OIL/WATER SEPARATORS LIST PRICE 01/18 EFFECTIVE: JANUARY 1, 2018 PUBLICATION NO. PG 11015H SUPERSEDES PG 11015G OIL/WATER SEPARATORS LIST PRICE EFFECTIVE: JANUARY 1, 2018 PUBLICATION NO. PG 11015H SUPERSEDES PG 11015G 01/18 CONDITIONS OF SALE Containment Solutions products must be installed according to current

More information

Recirculating Media Filters OWNER'S MANUAL

Recirculating Media Filters OWNER'S MANUAL 3649 Cane Run Road Louisville, KY 40211-1961, USA 1-800-928-7867 1-502-778-2731 Fax: 1-502-774-3624 clarusenvironmental.com SECTION: C3.20.140 CL0064 0515 Supersedes 1011 Recirculating Media Filters Register

More information

Sludge Thickening. Wastewater Treatment Review. Gravity Thickening

Sludge Thickening. Wastewater Treatment Review. Gravity Thickening Wastewater Treatment Review 10 Sludge Thickening nw ate rc oll e ge 20 Gravity Thickening ca Principle of Operation 1. Uses gravitational forces to separate water from sludge 2. Solids settle to bottom

More information

Flexible Couplings & Saddles

Flexible Couplings & Saddles Revised 6/01 Flexible Sewer couplings are the result of many years of experience with sewer pipe connections. Today's couplings are made of specially formulated elastomeric PVC with high tear and shear

More information

FIVE FOOT DIAMETER TANKS

FIVE FOOT DIAMETER TANKS Box 220, Highway 14 West, Asquith SK S0K 0J0 PH: (306) 329-4884 Toll Free: (866) 722-6246 FAX: (306) 329-4886 Email: sales@frpmfg.com Website: http://www.frpmfg.com FIVE FOOT DIAMETER TANKS Underground

More information

Teacher Assessment Blueprint. Heavy Equipment. Test Code: 5913 / Version: 01. Copyright 2007 NOCTI. All Rights Reserved.

Teacher Assessment Blueprint. Heavy Equipment. Test Code: 5913 / Version: 01. Copyright 2007 NOCTI. All Rights Reserved. Teacher Assessment Blueprint Heavy Equipment Test Code: 5913 / Version: 01 Copyright 2007 NOCTI. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information Written

More information

Environment Restoration Operations Solid Waste Management Unit (SWMU) 52: Filling Tanks 2 and 4 with a Permanent Insoluble Material - September 2013

Environment Restoration Operations Solid Waste Management Unit (SWMU) 52: Filling Tanks 2 and 4 with a Permanent Insoluble Material - September 2013 University of New Mexico UNM Digital Repository Environmental Restoration Sandia National Labs/NM Technical Reports 10-9-2013 Environment Restoration Operations Solid Waste Management Unit (SWMU) 52: Filling

More information

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual For Single-Wall and Double-Wall Fibreglass Underground Storage Tanks This Aquator Commercial Oil Water Separator (OWS)

More information

OPERATION & MAINTENANCE for Lamella plate separators OPERATION & MAINTENANCE QUICK GUIDE For models HB50 / HB20 / HB10

OPERATION & MAINTENANCE for Lamella plate separators OPERATION & MAINTENANCE QUICK GUIDE For models HB50 / HB20 / HB10 OPERATION & MAINTENANCE for Lamella plate separators OPERATION & MAINTENANCE QUICK GUIDE For models HB50 / HB20 / HB10 Lifting and Handling Do s Remove all water and solids contents before lifting or moving

More information

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION MAINTENANCE Installation, Operation INSTRUCTIONS and Maintenance SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION The A.R.I. Underground Air Valve System for water conveyance systems is a complete package

More information

Bobcat Backhoe Attachments

Bobcat Backhoe Attachments Backhoe Attachments M06 4 Bobcat Backhoe Attachments Turn your loader into a powerful part-time excavator. Ideal for landscaping, nursery work, sewage systems, septic tanks, water lines, power lines and

More information

Patton Hill Road (Four Inch Main), Project No

Patton Hill Road (Four Inch Main), Project No Patton Hill Road (Four Inch Main), Project No. 2016100 MP-5.01 MOBILIZATION (3% MAX) 1 LS MP-5.02.8(d) 8" DIP (CLASS 350) ALL DEPTHS 600 LF MP-5.02.6(p) 6" PVC ALL DEPTHS, INCLUDING BEDDING 10 LF MP-5.02.4(p)

More information

Septic Tank. Installation Guidelines

Septic Tank. Installation Guidelines Septic Tank Installation Guidelines INSTALLATION GUIDELINES FOR WPL SEPTIC TANKS These guidelines represent Best Practice for the installation of spherical SEPTIC tanks. It must be noted, however that

More information

VALVES, FIRE HYDRANTS, AND APPURTENANCES

VALVES, FIRE HYDRANTS, AND APPURTENANCES VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)

More information

Operation and Maintenance

Operation and Maintenance E-Z Set Company requires regular inspection and maintenance of the E-Z Treat Re- Circulating Sand/Media Filter, as a condition of purchase and ongoing operation compliance. The mandatory service contract

More information

Underground Gas Polyethylene (PE) Piping

Underground Gas Polyethylene (PE) Piping Underground Gas Polyethylene (PE) Piping Installation Guide February, 2011 Featuring the Con-Stab I.D. Seal Fittings from Continental Industries, Inc. ASSEMBLY INSTRUCTIONS: I.D. SEAL CON-STAB STEP 1 Verify

More information

BNR Series Wastewater Treatment Systems Washington State Installation & Owners Manual

BNR Series Wastewater Treatment Systems Washington State Installation & Owners Manual BNR Series Wastewater Treatment Systems Washington State Installation & Owners Manual Class I Wastewater Treatment Systems 500/550/600/800/1000/1500 Gallon per Day Capacity Commercial and Residential Systems

More information

City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017

City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017 Section 1. Purpose. City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017 The purpose of this regulation is to outline the wastewater pretreatment

More information

BNR Series Wastewater Treatment Systems Installation & Owners Manual

BNR Series Wastewater Treatment Systems Installation & Owners Manual BNR Series Wastewater Treatment Systems Installation & Owners Manual Class I Wastewater Treatment Systems 500/600/750/1000/1500 Gallon per Day Capacity Commercial and Residential Systems The Environmentally

More information

Two Sludges One Belt Press Waste Activated Sludge and Lime Sludge Handling

Two Sludges One Belt Press Waste Activated Sludge and Lime Sludge Handling Two Sludges One Belt Press Waste Activated Sludge and Lime Sludge Handling We are very satisfied with the Or-Tec Belt Press & the service provided by the Or-Tec Company. WEST LIBERTY The village of West

More information

ANNUAL UST SYSTEM INSPECTION CHECKLIST

ANNUAL UST SYSTEM INSPECTION CHECKLIST APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date

More information

WATER & WASTE management 2015 edition

WATER & WASTE management 2015 edition WATER & WASTE management 2015 edition Whether you re looking for a below ground septic or cistern tank or an above ground water tank, you re sure to find it among our wide selection. Our rotational molding

More information

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries Septic tanks A septic tank from Ri-Industries offers a number of benefits: Engineer-designed and built from fine tolerance steel moulds Tanks are made from 40 MPa concrete to give additional strength and

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance

More information

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide - Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.

More information

5220 SERIES Z-Cell OWNER'S MANUAL

5220 SERIES Z-Cell OWNER'S MANUAL 3649 Cane Run Road Louisville, KY 40211-1961, USA 1-800-928-7867 1-502-778-2731 Fax: 1-502-774-3624 clarusenvironmental.com CL0180 0817 Supersedes New 5220 SERIES Z-Cell OWNER'S MANUAL Register your Clarus

More information