Community Economic Development Association of Cook County LIHEAP FURNACE PROGRAM. Construction Task Catalog. Specification #: IFB

Size: px
Start display at page:

Download "Community Economic Development Association of Cook County LIHEAP FURNACE PROGRAM. Construction Task Catalog. Specification #: IFB"

Transcription

1 Community Economic Development Association of Cook County LIHEAP FURNACE PROGRAM Construction Task Catalog Specification #: IFB February 2014

2 THIS PAGE INTENTIONALLY LEFT BLANK

3 Table of Contents 00 Using The Construction Task Catalog 1 01 General Requirements Price And Payment Procedures Unit Prices CEDA Electric Health And Safety HVAC Insulation Vent Water Heater 5 February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page TOC - 1

4 Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK copyright 2014 The Gordian Group, Inc February 2014 Page TOC - 2 Community Economic Development Association of Cook County Emergency Furnace

5 Using The Construction Task Catalog CTC Information: 1 This Construction Task Catalog was developed and customized by The Gordian Group, Inc specifically for Community Economic Development Association of Cook County, priced locally using current labor, material and equipment costs, and published in February The Gordian Group, Inc licenses the use of this CTC and other proprietary information and software for the sole purpose of providing Job Order Contracting services to Community Economic Development Association of Cook County Use of The Gordian Group s CTC and other proprietary information and software for any other purpose or any other entity is expressly prohibited without the express written consent of The Gordian Group, Inc MasterFormat 1 The tasks in this Construction Task Catalog are organized using CSI s MasterFormat 2 Labor costs are based on workers familiar with and skilled in the performance of the task following OSHA requirements 3 Labor costs include time lost for normal work breaks, layout, measuring and cutting to fit, cleanup of regular construction debris, inspection, permit compliance, job meetings and start-up 4 Labor costs include complying with Lead Safe Weatherization and the Environmental Protection Agency / Renovate Repair and Paint (EPA / RRP) protocols EPA/ RRP protocols must be followed during all installations MATERIAL COSTS: 1 Material costs include the cost of the material being installed and all incidentals and accessories integral to the installation 2 Material costs include manufacturer's and/or fabricator's shop drawings 3 Material costs include an allowance for waste for such materials that are typically provided in standard widths, lengths, weights and units such as drywall, pipe, conduit, lumber This list is not intended to be all inclusive, but descriptive of the types of construction materials that are typically sold in standard lengths, sizes and weights The Unit Prices Include: LABOR COSTS: 1 Labor costs include direct labor through the working foreperson level at straight-time DOL wage rates for weatherization work including published fringe benefits and an allowance for Social Security and Medicare taxes, worker's compensation, unemployment insurance and employee benefits Complete and In-Place Construction: 1 Unit prices are for complete and in-place construction and include all labor, equipment and material required to complete the task as described in the CTC 2 Unit Prices include all deliveries, unloading and storing materials, tools and equipment on site, and moving materials, tools and equipment from storage area or truck to the Job Order site February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 00-1

6 Using The Construction Task Catalog 3 Unit prices include all fasteners such as anchor bolts, lag bolts, screws, adhesive, wedge anchors, expansion bolts, that are required 4 Unit prices include testing, calibration, balancing and the like required to ensure proper installation, construction and performance (balancing of heating ventilation and air conditioning, pneumatic or hydrostatic testing, soaping of joints, disinfection and flushing, others as required) The Adjustment Factors Include: BUSINESS COSTS: 1 Overhead costs, including, unless specifically excluded in the Contract Documents, but not limited to; home office overhead insurance, bonds, and indemnification project meetings, training, management and supervision mobilization and close-out for the contract and each Job Order project office staff and equipment 2 Profit 3 Subcontractor's overhead and profit 4 All taxes for which a waiver is not available including material sales tax and equipment rental 5 Employee or Subcontractor s wage rates that exceed the prevailing wage rates 6 Fringe benefits, payroll taxes, worker s compensation, insurance costs and any other payment mandated by law in connection with labor that exceeds the labor rate allowances 7 Cost of financing the work 8 Business risks such as the risk of a lower than expected volume of work, smaller than anticipated Job Orders, poor Subcontractor performance, and inflation or material cost increases CONSTRUCTION RELATED COSTS: 1 Services required to obtain permits The Contractor will be compensated for the cost of the actual permit 2 Costs incurred to investigate work sites necessary to prepare proposals and the preparation and modification of proposals, sketches, incidental drawings such as layout drawings detailing the connections and other layout drawings, submittals, digital photographs and other project records 3 Costs incurred to define and modify scopes as required to support a Job Order 4 Construction vehicles such as pick-up trucks, utility trucks, vans, service trucks, flat bed trucks, tractors, trailers, etc 5 Storage devices or items such as gang boxes and storage containers for Contractor's tools, equipment and materials 6 Personnel safety equipment (hard hats, ropes, harness, etc) and basic safety signage, railings, tape, roping, cable, markings, cones, etc 7 Meeting Owner security requirements 8 Excess waste including roofing, drywall, VCT, carpet, wall covering, ceiling tile, pipe, conduit, siding, concrete, etc This list is not intended to be all inclusive, but descriptive of the types of construction materials that are typically sold in standard lengths, sizes and weights 9 Removing and returning Owner's furniture and furnishings 10 Protection of all surfaces including those not in the scope of work from construction dust, debris or damage during construction up until final acceptance The methods of protection including plastic, paper, temporary Masonite and plywood (except for temporary walls), sealing doors or windows are the Contractor s responsibility copyright 2014 The Gordian Group, Inc February 2014 Page 00-2 Community Economic Development Association of Cook County Emergency Furnace

7 Using The Construction Task Catalog 11 Daily clean-up of the project area and associated construction debris outside the project area 12 Final professional project clean-up of the project area and all related construction debris outside the project area Costs resulting from inadequate supply of building materials, fuel, electricity, or skilled labor 13 Costs resulting from productivity loss 14 Working in extreme temperatures (below or above normal) or adverse conditions such as excessive rain, wind, sleet or snow 15 Differences in project size, complexity, and location 16 All costs for other than discreet items of work specifically required to complete a particular Job Order 17 All parking costs for Contractor's or Subcontractor's vehicles PRICE VARIATIONS: 1 Contractors may find differences in labor, equipment and material costs due to certain economic factors Variations in labor cost can also result from labor efficiency, labor restrictions, working conditions and local work rules Variations in material costs can also result from the quantity of material purchased, the existing relationship with suppliers, and because the materials have been discontinued or have become obsolete 2 While diligent effort is made to provide accurate and reliable up-to-date pricing, it is the responsibility of the Contractor to review and analyze the unit prices, and to calculate their Adjustment Factors accordingly, prior to bidding GENERAL COSTS: 1 This list is not exhaustive and is intended to provide general examples of costs to be included in the Contractor's Adjustment Factor as defined in the Contract 2 The only compensation to be paid to a Contractor for the work tasks will be: Published Unit Price X Installation (or Demolition) Quantity X Appropriate Adjustment Factor 3 No additional payments of any kind whatsoever will be made All costs not included in the unit prices must be part of the Adjustment Factors General Interpretations: 1 Assembly unit prices take precedence over individual component pricing 2 Whenever a material, article or piece of equipment is identified in the CTC or in the specifications by reference to manufacturers or vendors names, trade names, catalogue numbers, or make, the identification is intended to establish a standard Any material, article or equipment of another manufacturer or vendor which performs satisfactorily the duties imposed by the general design may be considered equally acceptable provided that, in the opinion of the Owner, the material, article or equipment so proposed is of equal quality, substance and function The Contractor shall not provide, furnish or install any proposed material, article or equipment without the prior written approval of the Owner The burden of proof and all costs related thereto concerning the "or equal" nature of the substitute item, whether approved or disapproved, shall be borne by the Contractor SPECIFICATIONS: 1 Specifications for tasks shall be interpreted as follows: All labor, material, equipment, spare parts, services, and work required by a specification shall be considered part of the unit price, unless the task description or technical specifications state otherwise February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 00-3

8 Using The Construction Task Catalog Useful Information: UNIT OF MEASURE DEFINITIONS: CFMR - Cubic Feet Per Minute Reduction, EA Each, LF - Linear Foot, MBH - One Thousand British Thermal Units, SF - Square Foot, UI - United Inch DEFINITION FOR TASK ABBREVIATIONS: ADJ Adjustable, ALUM Aluminum, APP Appliance, CFL Compact Fluorescent Light, CO Carbon Monoxide, DH Double Hung, EFE Efficiency, ELEC Electric, EQUIV Equivalent, FAF Forced Air Furnace, FG Fiberglass, FURN Furnace, GALV Galvanized, HTR Heater, MF Multi-Family, MH Mobile Home, NAT Natural, NG Natural Gas, PROP Propane, REP Replacement, STM Steam, SW Single Wall, TERM Termination, T-STAT Thermostat, WH Water Heater, WIND - Window 1 Meter = 100 Centimeters = Feet 1 Mile = 5280 Feet = Kilometers 1 Pound = Kilograms 1 Square Foot = 144 Square Inches = 0929 Square Meters 1 Square Meter = Square Yards = Square Feet 1 Square Yard = 9 Square Feet = Square Meters 1 Ton = 2000 Pounds = Kilograms 1 Yard = 3 Feet = Meters CONVERSIONS: 1 Acre = 43,560 Square Feet = Square Meters 1 Board Foot = 12 x 12 x 1 = 144 Cubic Inches Sheet Metal Thickness (inches) Gage Steel Galvanized Stainless Aluminum 1 Centimeter = Inches = Feet No Sheet Steel Sheet Steel Sheet Sheet Cubic Foot = Cubic Yards = Cubic Meters Cubic Meter = Cubic Yards = Cubic Feet Cubic Yard = 27 Cubic Feet = Cubic Meters Foot = 12 Inches = Meters Inch = 254 Centimeters = Meters Kilogram = Pounds Kilometer = Miles = 3280 Feet copyright 2014 The Gordian Group, Inc February 2014 Page 00-4 Community Economic Development Association of Cook County Emergency Furnace

9 Using The Construction Task Catalog STANDARD GEOMETRY: Circle Circumference = 2 π radius = π diameter Area = π radius 2 = π (diameter 2 / 4) Cylinder Volume = (π radius 2 )height Surface Area = 2 π radius 2 +(2 π radius)height Sphere Volume = (4 π radius 3 ) / 3 Surface Area = 4 π radius 2 π = United Inch The industry standard for measuring windows is the United Inch or UI The UI is determined by adding the width and the height in inches TRADEMARKS Gordian JOC Solution, JOC Complete Solution, JOC Complete Solution Plus, PROGEN, egordian, eziqc, Construction Task Catalog, Catalog of Construction Tasks, DMAP, The Standard for Job Order Contracting and 6 Phase Development and Implementation Process are either registered trademarks or trademarks of The Gordian Group, Inc The names of actual companies and products mentioned herein may be the trademarks of their respective owners February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 00-5

10 Using The Construction Task Catalog THIS PAGE INTENTIONALLY LEFT BLANK copyright 2014 The Gordian Group, Inc February 2014 Page 00-6 Community Economic Development Association of Cook County Emergency Furnace

11 General Requirements 01 Price And Payment Procedures Unit Prices MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST 01 General Requirements Price And Payment Procedures (01) Unit Prices (01 20) Unit Price Payment (01 22) Reimbursable Fees ( ) Note: Reimbursable fees include but are not limited to permits, special inspections, special insurance, A/E stamped drawings, additional warranties, etc, which are not included in a task or an Adjustment Factor as explained in the Contract or The Construction Task Catalog EA Reimbursable Fees 100 Note: Reimbursable fees will be paid to the contractor for the actual cost, without mark-up, for which a receipt or bill is received The Adjustment Factor applied to Reimbursable Fees will be The base cost of the Reimbursable Fee is $100 The quantity used will adjust the base cost to the actual Reimbursable Fee (eg quantity of 125 = $12500 Reimbursable Fee) If there are multiple Reimbursable Fees, each one shall be listed separately with a comment in the "note" block to identify the Reimbursable Fees (eg sidewalk closure, road cut, various permits, extended warrantee, expedited shipping costs, etc) A copy of each receipt shall be included with the Proposal XXXXXXX CEDA (01) Electric (01 97) EA A/C Disconnect ' Whip EA Circuit Breaker - Double Pole EA Circuit Breaker - Single Pole LF Conduit (Metal) - 1/2" Per Foot LF Conduit (Metal) - 3/4" Per Foot LF Elec Wire With Ground Per Foot LF Elec Wire BX With Ground Per Foot LF Elec Wire With Ground Per Foot LF Elec Wire BX With Ground Per Foot LF Elec Wire With Ground Per Foot LF Elec Wire With Ground Per Foot LF Elec Wire BX With Ground Per Foot LF Elec Wire With Ground Per Foot EA GFCI Receptacle EA GFCI Receptacle/Switch Combo EA Junction Box EA Junction Box Cover Health And Safety (01 97) EA CO Detector EA Dryer Vent Kit - Includes Term And Semi-Rigid Vent EA Fire Extinguisher EA Smoke Detector EA Smoke Detector - Hearing Impaired HVAC (01 97) LF Aluminum Flashing - Per Foot (Roof Flashing) EA 80% NG/Prop FAF - 40,000 BTU 1, EA 80% NG/Prop FAF - 60,000 BTU 1, EA 80% NG/Prop FAF - 80,000 BTU 1, EA 80% NG/Prop FAF - 100,000 BTU 1, EA 80% NG/Prop FAF - 120,000 BTU 1, EA 92% NG/Prop FAF - 40,000 BTU 1, EA 92% NG/Prop FAF - 60,000 BTU 1, EA 92% NG/Prop FAF - 80,000 BTU 1, EA 92% NG/Prop FAF - 100,000 BTU 1, EA 92% NG/Prop FAF - 120,000 BTU 1, EA 90% NG/Prop FAF - 40,000 BTU 1, EA 90% NG/Prop FAF - 60,000 BTU 1, EA 90% NG/Prop FAF - 80,000 BTU 1, EA 90% NG/Prop FAF - 100,000 BTU 1, EA 90% NG/Prop FAF - 120,000 BTU 1, EA 95% (Mod) NG/Prop FAF - 40,000 BTU 1, EA 95% (Mod) NG/Prop FAF - 60,000 BTU 1, EA 95% NG/Prop FAF - 80,000 BTU (Two Stage) 1, EA 95% NG/Prop FAF - 100,000 BTU (Two Stage) 2, EA 95% NG/Prop FAF - 120,000 BTU (Two Stage) 2, LF Black Pipe - 1/2" (Pipe, Fittings And Support) LF Black Pipe - 3/4" (Pipe, Fittings And Support) LF Black Pipe - 1" (Pipe, Fittings And Support) EA Black Pipe Cap - 1/2" EA Black Pipe Cap - 3/4" EA Black Pipe Cap - 1" EA Blower Compartment Safety Switch EA Blower Motor EA Blower Wheel EA Boiler FW - 80% EFE 40K BTU 1,12631 February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 01-1

12 01 01 General Requirements CEDA HVAC MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST EA Boiler FW - 80% EFE 60K BTU 1, EA Boiler FW - 80% EFE 70K BTU 1, EA Boiler FW - 80% EFE 85K BTU 1, EA Boiler FW - 80% EFE 100K BTU 1, EA Boiler FW - 80% EFE 130K BTU 1, EA Boiler FW - 80% EFE 150K BTU 1, EA Boiler FW - 80% EFE 165K BTU 1, EA Boiler FW - 80% EFE 200K BTU 1, EA Boiler FW - 90% EFE 100K BTU 2, EA Boiler FW - 90% EFE 130K BTU 2, EA Boiler FW - 90% EFE 150K BTU 2, EA Boiler FW - 90% EFE 165K BTU 3, EA Boiler FW - 90% EFE 200K BTU 3, EA Boiler Parts - Air Scoop EA Boiler Parts - Air Vent EA Boiler Parts - Aquastat EA Boiler Parts - Back Flow Preventer EA Boiler Parts - Boiler Gauges EA Boiler Parts - Circulator Pump LF Boiler Parts - Copper Pipe 1-1/2" Includes Fittings LF Boiler Parts - Copper Pipe 1-1/4" Includes Fittings LF Boiler Parts - Copper Pipe 1" Includes Fittings LF Boiler Parts - Copper Pipe 1/2" Includes Fittings LF Boiler Parts - Copper Pipe 2 1/2" Includes Fittings LF Boiler Parts - Copper Pipe 2" Includes Fittings LF Boiler Parts - Copper Pipe 3/4" Includes Fittings EA Boiler Parts - Discharge Pipe 3297 Note: For Boiler - Under 3' in length EA Boiler Parts - Drain Valve EA Boiler Parts - 30 Gallon Expansion Tank EA Boiler Parts - Flow Control Valve EA Boiler Parts - Isolation Valve EA Boiler Parts - Low Water Cut Off EA Boiler Parts - Outdoor Reset Control EA Boiler Parts - Outdoor Reset With ASBT EA Boiler Parts - Pressure Reducing Valve EA Boiler Parts - Pressure/Temperature Gauges EA Boiler Parts - Radiator (Labor Only) EA Boiler Parts - Radiator 4 Tube 14 Section EA Boiler Parts - Radiator 4 Tube 24 Section 1, EA Boiler Parts - Radiator 4 Tube 6 Section EA Boiler Parts - Radiator Valve EA Boiler Parts - Radiator Vent/Bleeder Valve EA Boiler Parts - Supply/Return Water Lines EA Boiler Parts - T And P Valve EA Boiler Parts - Triple Aquastat EA Boiler Part - Boiler Zone T-Stat EA Boiler Parts - Zone Valve And Rewire EA Burner Assembly (Furnace/Boiler) EA Chimney Cap EA Chimney Storm Collar- 4" EA Chimney Storm Collar- 5" EA Chimney Storm Collar- 6" EA Chimney Storm Collar- 7" EA Circuit Board EA Condensate Pump 1/30 HP EA Draft Inducer Motor EA Gas Sediment Trap EA Drip Leg (Discharge Pipe) 1100 Note: Sediment trap EA Duct Boot Round (4" x 10") 6" EA Duct Boot Round (4" x 10") 8" EA Duct Boot Round (4" x 12") 6" EA Duct Boot Round (4" x 12") 8" EA Elec Baseboard Htr - 2 FT EA Elec Baseboard Htr - 4 FT EA Elec Baseboard Htr - 6 FT EA Electric Furn - 10 KW (34,000 BTU) 1, EA Electric Furn - 18 KW (60,000 BTU) 1, EA Electric Furn - 20 KW (70,000 BTU) 1, EA Electric Furn - 23 KW 75,000 BTU) 1, EA Electric Furn - 24 KW (80,000 BTU) 1, EA Electric Furn - 25 KW (85,000 BTU) 1, EA Filter Rack (Includes Cover) EA Filter Rack Cover - Magnetic EA Filter Rack Cover - Sheet Metal EA Flame Rollout Sensor EA Flat Wall Return Grille - 16" x 20" EA Flat Wall Return Grille - 20" x 20" EA Flat Wall Return Grille - 20" x 25" LF Flex Tubing 3/8" - Cond Drain EA Floor Registers - 4" x 10" EA Floor Registers - 4" x 12" EA Floor Registers - 4" x 8" 1644 copyright 2014 The Gordian Group, Inc February 2014 Page 01-2 Community Economic Development Association of Cook County Emergency Furnace

13 General Requirements 01 CEDA HVAC MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST EA Floor Registers - 6" x 10" EA Floor Registers - 6" x 12" EA Floor Return Grille - 14" x 20" EA Floor Return Grille - 16" x 16" EA Floor Return Grille - 20" x 20" EA Furn Filter - 14" x 20" x 1" EA Furn Filter - 16" x 16" x 1" EA Furn Filter - 16" x 20" x 1" EA Furn Filter - 16" x 25" x 1" EA Furn Filter - 20" x 20" x 1" EA Furn Filter - 20" x 25" x 1" EA Gas App Conn 48" - 3/4" EA Gas Shut Off Valve - 1" EA Gas Shut Off Valve - 1/2" EA Gas Shut Off Valve - 3/4" EA Heat Pump (AS) - 15 Ton (DZ) 2, EA Heat Pump (AS) - 2 Ton (DZ) 2, EA High Limit Switch EA Hot Surface Ignitor LF Insulated Flex Duct - 4" LF Insulated Flex Duct - 6" LF Insulated Flex Duct - 8" EA Intermittent Ignition Device (lid) EA MH 80% NG/Prop FAF- 56,000 BTU 1, EA MH 80% NG/Prop FAF- 70,000 BTU 1, EA MH 80% NG/Prop FAF- 90,000 BTU 1, EA MH 95% NG/Prop FAF - 40,000 BTU 1, EA MH 95% NG/Prop FAF - 60,000 BTU 1, EA MH 95% NG/Prop FAF - 80,000 BTU 2, EA MH Electric Furn - 10 KW 1, EA MH Electric Furn - 12 KW 1, EA MH Electric Furn - 15 KW 1, EA MH Electric Furn - 20 KW 1, EA MH 95% Termination Roof Adapter/Seal EA MH Roof Jack EA Mini-Split (Dual Zone) - 1 Ton 2, EA Mini-Split (Dual Zone) - 15 Ton 2, EA Mini-Split (Dual Zone) - 2 Ton 2, EA Mini-Split (Single Zone) - 1 Ton 1, EA Mini-Split (Single Zone) - 15 Ton 2, EA Mini-Split (Single Zone) - 2 Ton 2, EA Module For IID EA Mother Board (Labor Only) EA Pilot Assembly Kit EA Pressure Switch LF PVC Pipe Ins - 2" To 3" LF PVC Pipe Ins - 3" To 4" LF PVC Pipe Ins - Up To 2" EA Return Air Filter Grille- 14" x 20" EA Return Air Filter Grille -14" x 25" EA Return Air Filter Grille - 16" x 16" EA Return Air Filter Grille - 16" x 20" EA Return Air Filter Grille - 16" x 25" EA Return Air Filter Grille - 20" x 20" EA Return Drop (8 Foot Drop) EA Return Plenum Note: For supply or return EA Return Transition Note: For supply or return EA Roof Adapter/Seal For 90% Vent Termination EA Roof Term Kit- 95% MH Furn LF Round Duct Insulation - 4" (Includes Connector And Support) LF Round Duct Insulation - 6" (Includes Connector And Support) LF Round Duct Insulation - 8" (Includes Connector And Support) EA Sheet Metal - Per Sheet (Includes 32 SF) EA Space Htr - Floor Mat EA Space Htr NG/P 80% - 20K BTU With Blower And Mat 1, EA Space Htr NG/P 80% - 20K BTU With Blower And Mat (DV) 1, EA Space Htr NG/P 80% - 35K BTU With Blower And Mat 1, EA Space Htr NG/P 80% - 35K BTU With Blower And Mat (DV) 2, EA Space Htr NG/P 80% - 40K BTU With Blower And Mat 1, EA Space Htr NG/P 80% - 40K BTU With Blower And Mat (DV) 2, EA Space Htr NG/P 80% - 50K BTU With Blower And Mat 1, EA Space Htr NG/P 80% - 50K BTU With Blower And Mat (DV) 2, EA Space Htr NG/P 80% - 65K BTU With Blower And Mat 1, EA Space Htr NG/P 80% - 65K BTU With Blower And Mat (DV) 2, EA Space Htr Tall Wall Mount (DV) - 55K BTU With Blower 1, EA Space Htr Tall Wall Mount (NO) - 40K BTU Dual Dir With Blower 1, EA Space Htr Tall Wall Mount- 40K BTU Nat Draft With Blower 1, EA Space Htr Tall Wall Mount- 55K BTU Nat Draft With Blower 1, EA Space Htr Wall Mount (DV) - 15K BTU 1, EA Space Htr Wall Mount (DV) - 25K BTU 1, EA Spark Ignitor 8630 February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 01-3

14 01 01 General Requirements CEDA HVAC MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST EA SSY Assembly 2375 Note: Electrical disconnect switch EA Stm Boiler- 80% EFE 60K BTU 1, EA Stm Boiler- 80% EFE 70K BTU 1, EA Stm Boiler- 80% EFE 80K BTU 1, EA Stm Boiler- 80% EFE 100K BTU 1, EA Stm Boiler- 80% EFE 125K BTU 1, EA Stm Boiler - 80% EFE 150K BTU 1, EA Stm Boiler - 80% EFE 175K BTU 2, EA Stm Boiler - 80% EFE 200K To 225K BTU 2, EA Stm Boiler - 80% EFE 225K To 276K BTU 2, EA Stm Boiler Parts - Air Vent EA Stm Boiler Parts - Blow Off Valve For Low Water Cut Off EA Stm Boiler Parts - Boiler Relay EA Stm Boiler Parts - Combo Feeder/Cut Off EA Stm Boiler Parts - Hartford Loop EA Stm Boiler Parts - Internal Limit Control EA Stm Boiler Parts - Limit Control EA Stm Boiler Parts - Low Water Cut Off EA Stm Boiler Parts - Outdoor Cut Off EA Stm Boiler Parts - Pressure Valve EA Stm Boiler Parts - Radiator Bleeder/Pressure Relief EA Stm Boiler Parts - Water Column Site Glass Kit EA Stm Boiler Parts - Water Column Site Glass Kit With Drain EA Stm Boiler Parts - Water Feeder EA Supply Plenum EA Supply Transition EA T-Stat (Digital) - Heat/Cool EA T-Stat (Digital) Visually Imp - Heat/Cool EA T-Stat (Prog) - Heat/Cool EA T-Stat (Prog) Visually Imp - Heat/Cool LF T-Stat Wire 18-2 Per Foot LF T-Stat Wire 18-4 Per Foot LF T-Stat Wire 18-5 Per Foot LF T-Stat Wire 18-8 Per Foot EA Thermocouple EA Transfer Grille - 20" x 20" (2 Must Be Used) EA Transfer Grille- 14" x 20" (2 Must Be Used) EA Transfer Grille - 6" x 10" (2 Must Be Used) EA Transfer Grille - 6" x 14" (2 Must Be Used) EA Transfer Grille- 16" x 16" (2 Must Be Used) EA Transformer Relay 12-Volt (12/24 Volt) EA Wall/Ceiling Registers - 4" x 10" EA Wall/Ceiling Registers - 4" x 12" EA Wall/Ceiling Registers - 6" x 10" EA Wall/Ceiling Registers - 6" x 12" Insulation (01 97) SF Cellulose Dense Pack - R-11 (Includes Rmv And Rpl Siding, Wall Patches And Plugs) SF Cellulose Dense Pack - R-11 Interior Drill (Includes Wall Patches And Plugs) SF Cellulose Dense Pack - R-19 (Includes Rmv And Rpl Siding, Wall Patches And Plugs) SF Cellulose Dense Pack - R-19 Interior Drill (Includes Rmv And Rpl Siding, Wall Patches And Plugs) Vent (01 97) LF B-Vent - 3" LF B-Vent - 4" LF B-Vent - 5" LF B-Vent - 6" EA B-Vent Cap - 3" EA B-Vent Cap - 4" EA B-Vent Cap - 5" EA B-Vent Cap - 6" EA B-Vent Cap - 8" EA B-Vent Storm Collar - 3" EA B-Vent Storm Collar - 4" EA B-Vent Storm Collar - 5" EA B-Vent Storm Collar - 6" EA B-Vent Storm Collar - 8" EA Chimney Liner 4" - 1 Story EA Chimney Liner 4" - 2 Story EA Chimney Liner 5" - 1 Story EA Chimney Liner 5" - 2 Story EA Chimney Liner 6" - 1 Story EA Chimney Liner 6" - 2 Story EA Concentric Vent 2" EA Concentric Vent 3" LF Dryer Vent Pipe - 4" EA Dryer Vent Termination LF PVC Schd 40-2" Per Foot (Includes Pipe, Fittings And Supports) LF PVC Schd 40-3" Per Foot (Includes Pipe, Fittings And Support) LF PVC Schd 40-3/4" Per Foot (Includes Pipe, Fittings And Support) LF SW Vent - 3" (Includes Pipe, Fittings And Supports) LF SW Vent - 4" (Includes Pipe, Fittings And Supports) LF SW Vent - 5" (Includes Pipe, Fittings And Supports) 508 copyright 2014 The Gordian Group, Inc February 2014 Page 01-4 Community Economic Development Association of Cook County Emergency Furnace

15 General Requirements 01 CEDA Vent MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST LF SW Vent - 6" (Includes Pipe, Fittings And Supports) LF SW Vent - 8" (Includes Pipe, Fittings And Supports) EA SW Vent Cap - 4" EA SW Vent Cap - 5" EA SW Vent Cap - 6" EA SW Vent Cap - 8" EA SW Vent WYE- 3" (Single Wall) EA SW Vent WYE- 4" (Single Wall) EA SW Vent WYE- 5" (Single Wall) EA SW Vent WYE- 6" (Single Wall) EA SW Vent WYE- 8" (Single Wall) EA Vent Damper (Barometric Damper) Water Heater (01 97) EA TPR Valve EA WH Discharge Pipe 3300 Note: Long pipe over 5' length END OF SECTION 01 February 2014 copyright 2014 The Gordian Group, Inc Community Economic Development Association of Cook County Emergency Furnace Page 01-5

16 01 01 General Requirements CEDA Water Heater MINOR TOTAL DIRECT DEMOLITION CSI UOM DESCRIPTION UNIT COST UNIT COST THIS PAGE INTENTIONALLY LEFT BLANK copyright 2014 The Gordian Group, Inc February 2014 Page 01-6 Community Economic Development Association of Cook County Emergency Furnace

17 THIS PAGE INTENTIONALLY LEFT BLANK

18

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost Spend study of price carries out by Margins ratios (rate on selling price) Mark up (coef. on cost price) - Overheads 15,00% Mark up (N1) 1,25 - Profits 2,00% - Mark up N 1 1,20 1 - Consulting firm fees

More information

Component Coverage* A/C Presidential Plan. A/C Executive Plan $ $278

Component Coverage* A/C Presidential Plan. A/C Executive Plan $ $278 Honest Abe Plumbing, Heating, and Cooling is pleased to offer you our exclusive maintenance agreements. Our Executive and Presidential plans not only offer our thorough annual inspection, and priority

More information

ATTACHMENT I BID SCHEDULE IFB NO , CHURCH FARMS EAST STORAGE TANK AND BOOSTER PUMP STATION

ATTACHMENT I BID SCHEDULE IFB NO , CHURCH FARMS EAST STORAGE TANK AND BOOSTER PUMP STATION ATTACHMENT I BID SCHEDULE IFB NO. 19-021, CHURCH FARMS EAST STORAGE TANK AND BOOSTER PUMP STATION Item No. Description Qty Unit Unit Cost Amount Pump Station Site Work 1 Site Demolition / Removals / Haul

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

CONSTRUCTION MANAGER/GENERAL CONTRACTOR METHOD OF PAYMENT

CONSTRUCTION MANAGER/GENERAL CONTRACTOR METHOD OF PAYMENT Phase: OFF-SITE SERVICES AND STAFF 1 Corporate Executives 2 Principal in Charge 3 Project Executive 4 Legal (Basic Service) 5 Project Manager 6 Accounting 7 Added Accounting for Lender 8 Scheduling 9 Special

More information

Trade Price Book - 816

Trade Price Book - 816 Trade Price Book - 816 Effective 8/29/16 Green Mountain Gas-Fired Boilers Customer Service Corporate Sales Literature Technical Support Phone: 877-386-5475 literature@ecrinternational.com Phone: 800-325-5479

More information

SUBMITTAL COVER SHEET

SUBMITTAL COVER SHEET SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.

More information

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower TECHNICAL SPECIFICATIONS R6GF Series Rev B Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower R6GF 15 SEER, 81% AFUE 2-5 Ton Units These single packaged gas/electric systems

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances. SYSTEM CONTROL KIT Model: CK-41F Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances. ITEMS INCLUDED IN KIT: 1- Junction box with mounted pressure switch

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained

More information

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage

More information

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT The County of Hancock, Maine is seeking bids from qualified firms for the purchase and installation of at least a 20KW backup generator

More information

SCHEDULE E: TRAINING AIDS

SCHEDULE E: TRAINING AIDS 1.0 CONTRACT FOR X# Buses, BASE ONLY Total Price No. Qty. Description of Item Unit Price U.S. Dollars 1 X# "Type X" Buses, Base Buy (From Schedule A, column H line 161) 2 X# Optional X# year/x# mile PPA

More information

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG1GD Series M1010 Product Line Single Packaged Gas/Electric Units 13 SEER 2-5 Ton Units 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The PPG1GD

More information

NAME OF BIDDER MERCER GROUP INTERNATIONAL OF NJ, INC CALHOUN STREET CITY, STATE, ZIP TRENTON, NJ 08638

NAME OF BIDDER MERCER GROUP INTERNATIONAL OF NJ, INC CALHOUN STREET CITY, STATE, ZIP TRENTON, NJ 08638 CONTRACT AWARD AB2018-03 REMOVAL AND DISPOSAL OF SOLID WASTE AND RECYCLABLES FROM VARIOUS LOCATIONS IN MERCER BID OPENING DATE: APRIL 10,2018 CONTRACT TERM: MAY 30, 2018 RES. NO. 2018-280 THROUGH APRIL

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.15.1 - BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) A. Applicability The provisions of this

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

STATE OF MINNESOTA EQUIPMENT SPECIFICATION. SPECIFICATION: September 2012 Page 1 SINGLE AXLE CAB & CHASSIS

STATE OF MINNESOTA EQUIPMENT SPECIFICATION. SPECIFICATION: September 2012 Page 1 SINGLE AXLE CAB & CHASSIS STATE OF MINNESOTA EQUIPMENT SPECIFICATION SPECIFICATION: 330-912 September 2012 Page 1 1.0 SCOPE SINGLE AXLE CAB & CHASSIS This unit shall be a currently advertised production model as modified per specifications

More information

Sub - contractor Equip. $ UNIT PRICE TOTAL MAT. Unit $

Sub - contractor Equip. $ UNIT PRICE TOTAL MAT. Unit $ 330,000 SF High School Schedule: 25 Months PLUMBING ESTIMATED QUANTITY SURVEY Item Code Description Qnty Unit Material $ Labor MH Lab. Rate Labor $ 00001.00 General Conditions : 00001-00001.01 General

More information

Composite PEX-AL-PEX Tubing

Composite PEX-AL-PEX Tubing 04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192

More information

Special Specification 7010 Debris Removal and Disposal

Special Specification 7010 Debris Removal and Disposal Special Specification 7010 Debris Removal and Disposal 1. DESCRIPTION Provide emergency removal and disposal of debris from the highway right of way which is created by a hurricane or other type of natural

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model P6SD Series M120 Product Line Single Packaged Air Conditioning, 13 SEER - R-410A, 3, 4 and 5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability

More information

Gas Conversion Kits and Instructions

Gas Conversion Kits and Instructions General and Warnings FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately.

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

SUBMITTAL COVER SHEET

SUBMITTAL COVER SHEET SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.

More information

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

BUILDING PERMIT FEES

BUILDING PERMIT FEES D-2-a 07/01/11 BUILDING PERMIT S COMMERCIAL RATES Rate MINIMUM New Assembly New Business New Education New Factory/Industrial New Institutional New Mercantile New Storage New Miscellaneous Renovation/Change

More information

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS RULE 1146.1. EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (a) Definitions 1. ANNUAL HEAT INPUT means the actual amount

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida (813) Addendum No. 1

Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida (813) Addendum No. 1 Purchasing Services 4202 East Fowler Avenue, SVC 1073 Tampa, Florida 33620 (813) 974-2481 Invitation to Bid No.: 18-12-YH Entitled: Opening Date: Bulk Fuel Delivery (PATS) November 14, 2017 at 3:00 p.m.

More information

FABER BURNER ROUTINE MAINTENANCE

FABER BURNER ROUTINE MAINTENANCE FABER BURNER ROUTINE MAINTENANCE Version 2016 The Faber burner is designed for minimal maintenance; however, the frequency and quantity of maintenance that is required depends upon many factors which vary

More information

BID FOR A ONE (1) ONE-TON AND A HALF (5500 SERIES) CREWCAB TRUCK WITH DUMP BED. BID OPENING February 15, 2017 AT 10:00 A.M.

BID FOR A ONE (1) ONE-TON AND A HALF (5500 SERIES) CREWCAB TRUCK WITH DUMP BED. BID OPENING February 15, 2017 AT 10:00 A.M. P. O. B o x 1 5 4 0 T h o m a s v i l l e, G A 3 1 7 9 9 2 2 9-2 2 7-7 0 0 0 F A X 2 2 9-2 2 7-3 2 4 3 w w w. t h o m a s v i l l e. o r g BID FOR A ONE (1) ONE-TON AND A HALF (5500 SERIES) CREWCAB TRUCK

More information

SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT:

SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT: SYSTEM CONTROL KIT Model: CK-41F ITEMS INCLUDED IN KIT: 1) Junction box with mounted pressure switch and post purge timer 1) Fan control gas pressure switch 1) 2 ft. length of 1/4 inch aluminum tubing

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481038 Model PVF(-H) and PVG Indirect Gas-Fired Heat Modules Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions for future reference.

More information

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL INTRODUCTION This policy has been adopted by the Board of Public Works as a guide to obtaining electric service and to set forth the services available, conditions for service, and standards for materials

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES DIVISION 311 MISCELLANEOUS ELECTRICAL RULES 918-311-0000 Design, Planning and Lay Out of Electrical Installations by Supervising Electricians A licensed supervising electrician may design, plan and lay

More information

BUILDING PERMIT FEES BUILDING VALUATION DATA

BUILDING PERMIT FEES BUILDING VALUATION DATA BUILDING PERMIT FEES BUILDING VALUATION DATA The unit costs are intended to comply with the definition of "valuation" in Section 223 of the 1997 Uniform Building Code and thus include architectural, structural,

More information

Tow Truck Licensing By-law Open House

Tow Truck Licensing By-law Open House Tow Truck Licensing By-law Open House Learn what the proposed by-law will mean to you as a tow truck owner, driver or an owner of a motor vehicle storage yard. We want to hear from you! Come in and tell

More information

New RepairBase Line Item additions for the Update

New RepairBase Line Item additions for the Update Carpet & Structure Drying Equipment Install Drain Hose on Dehumidifier - Includes Directing to Exterior or Proper Drain Area Doors Hardware Replace Slide Bolt on Door - Includes Removal if Needed Fences

More information

Applies to: Models F, B, FE, and BE with spark pilot

Applies to: Models F, B, FE, and BE with spark pilot Form CP-F/B-GC (11/17) R8 Obsoletes Form CP-F/B-GC (Version A.2) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE with spark pilot NOTE: Units with standing (match - lit) pilots

More information

Home Dryers Refer to Page 3 for Model Numbers

Home Dryers Refer to Page 3 for Model Numbers Home Dryers Refer to Page 3 for Model Numbers Parts DRY691C_512174 www.comlaundry.com Part No. 512174R7 October 2009 Table of Contents Title Page Parts Ordering Information... 2 Nameplate Location...

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Commercial Dryers. Parts. Metered and Nonmetered. Refer to Page 3 for Model Numbers. DRY721C_515202

Commercial Dryers. Parts. Metered and Nonmetered. Refer to Page 3 for Model Numbers.  DRY721C_515202 Commercial Dryers Metered and Nonmetered Refer to Page 3 for Model Numbers Parts DRY721C_515202 www.alliancelaundry.com Part No. 515202R1 April 2015 Table of Contents Title Page Parts Ordering Information...

More information

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993 ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE GAS FURNACES SYSTEMS 50hz G21Q PULSE21 SERIES UP-FLO GAS FURNACES 11.4 to 27.8 kw (39 000 to 95 000 Btuh) Output Add-On Cooling 5.3 thru 17.6 kw (1-1/2

More information

Laars Heating Systems maintains a policy of continuous quality improvement.

Laars Heating Systems maintains a policy of continuous quality improvement. Using Genuine Laars parts will ensure accurate replacement and warranty coverage. Installation and Operation Manuals for current products are available on-line at www.laars.com Our Commitment We believe

More information

Home Dryers. Parts. Refer to Page 3 for Model Numbers. DRY731C_D517186

Home Dryers. Parts. Refer to Page 3 for Model Numbers.  DRY731C_D517186 Home Dryers Refer to Page 3 for Model Numbers Parts DRY731C_D517186 www.alliancelaundry.com Part No. D517186 March 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate Location...

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

MOBILE FOOD PREPARATION VEHICLE GUIDELINES

MOBILE FOOD PREPARATION VEHICLE GUIDELINES MOBILE FOOD PREPARATION VEHICLE GUIDELINES A mobile food preparation vehicle (MFPV) is defined as a commercially-manufactured, motorized mobile food establishment in which ready-to-eat food is cooked,

More information

DELETE first sentence of first paragraph that reads: REPLACE with the following:

DELETE first sentence of first paragraph that reads: REPLACE with the following: To Bidder of Record: SAN ANTONIO WATER SYSTEM Addendum 2 To Construction Documents For 2012 WATER & SEWER CONSTRUCTION CONTRACT, PACKAGE I SAWS WATER JOB NO. 12-5001 SAWS SEWER JOB NO. 12-5501 Solicitation

More information

BISCAYNE POINT ROW IMPROVEMENTS

BISCAYNE POINT ROW IMPROVEMENTS NEIGHBORHOOD & PROJECT NAME FUNDING SOURCE NO. 1 BISCAYNE POINT NEIGHBORHOOD BISCAYNE POINT ROW IMPROVEMENTS BISCAYNE POINT AREA STREETSCAPE G.O. BONDS IMPROVEMENTS WATER & SEWER BISCAYNE POINT WATER LINE

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

METAL STUDS. TOTAL COST (Labor+ Material) UNIT COST (Labor+ Material) ITEM # DESCRIPTION QUANTITY UNIT TRADE COST GENERAL REQUIREMENTS

METAL STUDS. TOTAL COST (Labor+ Material) UNIT COST (Labor+ Material) ITEM # DESCRIPTION QUANTITY UNIT TRADE COST GENERAL REQUIREMENTS GENERAL REQUIREMENTS 1 Supervision (5%) 1.00 LS 0.00 $0 2 Permits (5%) 1.00 LS 0.00 $0 3 Final Cleanup (0.2 Per SF) 1.00 LS 0.00 $0 4 Mobilization Costs (5%) 1.00 LS 0.00 $0 5 Project Overheads (7.3%)

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SE Series M1200 Product Line Single Packaged Heat Pump 14 SEER - 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR

More information

Group Class Code Listing

Group Class Code Listing Group Class Code Listing 1000 Automotive; Parts, Components, Vehicles 1160 Surplus - Bus & Bus Parts 1010 Automotive Parts 1200 Trolleys; Parts, Components 1020 Automotive - Testing Equipment 1202 Trolley

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Answer Key. Do Not Distribute

Answer Key. Do Not Distribute 2017 Page 1 of 6 STUDENTS DO NOT OPEN THIS TEST OR BEGIN UNTIL INSTRUCTED TO START 2017 Examination for the National Agricultural Technology and Mechanical Systems Career Development Event Name Print Name

More information

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5 TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum

More information

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units TECHNICAL SPECIFICATIONS GP4SN Series Single Packaged Electric Cooling Units P4SN 10.3 EER Commercial System 7½ and 10 Ton Units These 7½ and 10 ton units are designed specifically for retrofit applications

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units TM TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only.

POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only. POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only. 908-489 02/26/99 Table of Contents Tools and Instruments...3 Problem A Pilot not igniting after repeated

More information

Instruction and Installation Guide

Instruction and Installation Guide Instruction and Installation Guide Type 2A Arc Resistant tiastar Motor Control Center www.usa.siemens.com/mcc DANGER Hazardous voltage. Will cause death or serious injury. Keep out. Qualified personnel

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information