1 OPERATORS HANDBOOK MECHANICAL PRIME (SY) RANGE OF PRIMING EQUIPMENT FOR CENTRIFUGAL PUMPS SYPrim e.cd r ACME Dynamics, Inc. P. O. Box 1780 Plant City Florida Telephone: (813) (800) Fax: (813) Document No: W78-001E Revision No:... 2 Revision Note No: R Date Issued. Sept Produced at ACME Dynamics, Inc.

2 DECLARATION OF INCORPORATION FOR: DYNAPRIME RANGE OF PRIMING EQUIPMENT FOR CENTRIFUGAL PUMPS Types - SY18, SY25 & SY60 Serial Number Responsible Person Manufacturer REFER TO THE PUMP NAMEPLATE Sterling Fluid Systems Ltd. Sterling Fluid Systems Ltd. It is hereby certified that this equipment is intended to be incorporated into, or assembled with other machinery to constitute relevant machinery to comply with the essential health and safety requirements of the 'Council Directive 89/392/EEC - 'Machinery Directive'. The machinery covered by this declaration must T be put into service until the relevant machinery into which it is to be incorporated has been declared in conformity with the provisions of the 'Council Directive 89/392/EEC - 'Machinery Directive' Harmonized Standards: EN 292 Part 1 Part 2 pr EN 809: Safety of Machinery - Basic Concepts and General Principles for Design Pumps & Pump Units for Liquids - Safety Requirements B Millward Signed: (Chief Engineer - Authorized to sign on behalf of Sterling Fluid Systems Limited) A MEMBER OF THE STERLING FLUID SYSTEMS GROUP

3 Operators Handbook for Manual No/Rev CONTENTS Section... Page 1 General Information & Safety Instructions Transport Handling and Storage General Description Assembly and Installation Commissioning and Operation Maintenance and Service Faults and Remedial Action Supplementary Documents...8 After Sales Service... Back Cover Introduction This manual gives the safety, installation, operation and maintenance instructions for the ACME Dynamics DYNAPRIME SY range of priming equipment for use with end suction, centrifugal pumps. The priming equipment may be identified by the ACME Dynamics, Inc. code typically in the form 'SY60'. This manual applies to the following priming systems. SY18, SY25 & SY60 SY18 has an 18cfm vacuum pump; similarly SY25 and SY60 have 25 & 60cfm vacuum pumps. Section 1 General Information and Safety Instructions The products supplied by ACME Dynamics, Inc. have been designed with safety in mind. Where hazards cannot be eliminated, the risk has been minimised by the use of guards and other design features. Some hazards cannot be guarded against and the instructions below MUST BE COMPLIED WITH for safe operation. These instructions cannot cover all circumstances; YOU are responsible for using safe-working practices at all times. 1.1 ACME Dynamics, Inc. products are designed for use in appropriate locations which are to be kept free of obstructions that may restrict safe access to the controls and maintenance access points. Should accidental loss or damage occur, contact ACME Dynamics, Inc. immediately. 1.2 Access to the equipment should be restricted to the personnel responsible for installation, operation and maintenance and they must be trained, adequately qualified and supplied with the appropriate tools for their respective tasks. 1.3 ACME Dynamics, Inc. requires that all personnel that are responsible for installation, operation or maintenance of the equipment, have access to and study the product instruction manual BEFORE any work is done and that they will comply with all local and industry based safety instructions and regulations. 1.4 Ear defenders should be worn where the specified equipment noise level exceeds locally defined safe levels. Safety glasses or goggles should be worn where working with pressurised systems and hazardous substances. Other personal protection equipment must be worn where local rules apply. 1.5 Do T wear loose or frayed clothing or jewellery, which could catch on the controls or become trapped in the equipment. 1.6 Note any limits to the pump application specified in the contract documentation. Operation of the equipment outside these limits will increase the risk from hazards noted below and may lead to premature and hazardous pump failure. 1.7 Clear and easy access to all controls, gauges and dials etc. MUST be maintained at all times. 1.8 IMPROPER INSTALLATION, OPERATION OR MAINTENANCE OF THIS ACME Dynamics, Inc. PRODUCT COULD RESULT IN INJURY OR DEATH. 1.9 Within the manual, safety instructions are marked with safety symbols. Hazard This symbol refers to general mechanical aspects of safety. A nameplate is fitted to each pump unit and must not be removed as it identifies the priming equipment supplied with the pump. Loss of this plate could make identification impossible. This in turn could affect safety and cause difficulty in obtaining spare parts. Page 1

4 Manual No/Rev Operators Handbook for ATTENTION Hazard This symbol refers to electrical safety. This symbol gives warning of a hazard to the equipment itself, which in turn could cause a risk to personal safety. Section 2 Transport Handling and Storage Instructions 2.1 Transport DYNAPRIME equipment is despatched fully assembled but for overseas orders the lubricating oil is drained. Equipment is protected against corrosion and packed for transport by normal road, rail and sea carriers. 2.2 Handling Crushing Hazard When lifting, use lifting equipment having a safe working load rating suitable for the weight specified. Use suitable slings for lifting any item not provided with lifting points. The use of suitable forklift truck and fourchain crane sling equipment is recommended but locally approved equipment of suitable rating maybe used. Priming equipment is normally supplied on pallets, which may be lifted by forklift truck. 2.3 Storage Section 3 General Description ACME Dynamics DYNAPRIME SY Priming Equipment is designed to be used with a variety of end suction centrifugal pumps to handle dirty water, industrial effluents, and sludge etc, including solids. There are three main components: 3.1 Priming Tank Assembly The priming tank assembly is fitted to the suction branch of the pump. It provides for removal air drawn from the suction line and contains protection devices to prevent water from getting to the vacuum pump. 3.1 Vacuum Pump & Coalescer Belts drive the vacuum pump from the pump drive shaft; this draws air from the priming tank and passes it to the coalescer. The vacuum pump is lubricated by oil, some of which mixes with the air. The coalescer is required for the larger vacuum pumps to separate the oil from the air thus discharging clean air to atmosphere and recycling the oil for lubrication. 3.3 Non Return Valve The non-return valve is fitted to the discharge of the pump to prevent back flow or entry of air when priming the system. Section 4 Assembly and Installation 4.1 Initial Inspection for Damage Temporary Storage If the equipment is not to be used immediately it should be stored carefully in a horizontal position, in a sheltered, dry location. Additional rust preventative should be applied to all unpainted carbon steel or cast iron parts, and should not be removed until final installation Exposed or Extreme Conditions Storage For exposed storage or extreme variants in atmospheric or environmental conditions, please refer to ACME Dynamics, Inc. for special storage instructions to suit the conditions applicable. During transport and storage, accidental damage to the equipment may have occurred. Prior to installation, or in the event of a handling accident, carefully check that no damage has been sustained before installation and commissioning. 4.2 Pump Mounting Abrasion and Entrapment Hazard Do T touch any moving or rotating parts. Guards are provided to prevent access to these parts, where they have been removed for maintenance they MUST be replaced before operating the equipment. The pump is to be mounted as per instruction in the pump manual. Suitable drive pulleys for the vacuum pump are usually to be fitted on the pump shaft between the bearing housing and the coupling. Guarding for the belt drive is Page 2

5 Operators Handbook for Manual No/Rev required to meet local safety standards. 4.3 Shaft Alignment Shaft alignment is to be set and checked as per instructions in the pump or coupling instruction manual. 4.4 Coalescer Mounting The coalescer is designed for mounting below the pump-bearing bracket, but may be fitted in any other suitable position giving clear access to the maintenance points. 4.5 Priming Tank Mounting The priming tank was designed to be mounted directly to the suction branch of the pump. It must be maintained within 10 degrees of vertical for satisfactory operation. 4.6 Suction Pipework ATTENTION Collapsible hoses must not be used on the suction side of the pump. A correctly sized filter or strainer is recommended to hold back larger items. 4.7 Non Return Valve and Discharge Pipework The non-return valve is usually fitted in the discharge line close to the pump to prevent the pump from excessive back-pressure and reverse rotation and to prevent air from entering when the pump is being primed. Section 5 Commissioning and Operation 5.1 Commissioning Checks These checks must be done before testing and first use and after priming system maintenance, which required disassembly. Abrasion and Entrapment Hazard Do T touch any moving or rotating parts. Guards are provided to prevent access to these parts, where they have been removed for maintenance they MUST be replaced before operating the equipment. The following checks refer only to the priming equipment, pump and driver checks must be done as per their manuals. Fill the coalescer with the recommended oil to the level of the filler cap. Check the tension of the vacuum pump drive belts. Check that the non-return valve is seating properly and that there is no debris in the chamber to prevent correct operation. Check that the surge control valve is fully screwed in. This is the large knurled nut surrounding the back flush knob on the top of the priming tank. 5.2 Starting Procedure Cold Conditions Hazard Do T operate water pumps in temperatures below freezing point, without first checking that the pumped fluid is not frozen and the pump is free to turn. Start the pump as per the pump instruction manual. The pump should prime automatically, if not refer to the Fault Finding Guide in Section Stopping Procedure Stop the engine or motor, and then close any valves in the discharge pipes. Section 6 Maintenance and Service 6.1 General Introduction ACME Dynamics DYNAPRIME equipment will provide many years of trouble free service when maintained in accordance with these instructions. In the event of failure it is recommended that ACME Dynamics, Inc. Service Department be called to investigate and carry out repairs. The following instructions are given to cover the main elements of strip and rebuild but do T include instructions for work that MUST be done by an ACME Dynamics, Inc. Service Engineer. The following hazards may arise during maintenance work: Page 3

6 Manual No/Rev Operators Handbook for Fluid Pressure Jet Hazards Check and ensure that the pump operates at below the Maximum Working Pressure specified on the pump nameplate and before maintenance, ensure that the pump is drained down. Hazardous Materials Wear a suitable mask or respirator when working with Packing and Gasket components, which contain fibrous material, as these can be hazardous when the fibrous dust is inhaled. Be cautious, if other supplier's components have been substituted for genuine ACME Dynamics parts, these may then contain hazardous materials. Hazardous Gases, Mists, Sprays and Leaks Be aware of the hazards relating to the pumped fluid, especially the danger from inhalation of noxious and toxic gases, skin understand the hazardous substance data sheets relating to the pumped fluid and note the recommended emergency and first aid procedures. BEFORE ATTEMPTING ANY MAINTENANCE ON A PUMP, PARTICULARLY IF IT HAS BEEN HANDLING ANY FORM OF HAZARDOUS LIQUID, ENSURE THAT THE UNIT IS SAFE TO WORK ON. THE PUMP MUST BE FLUSHED THOROUGHLY WITH A SUITABLE CLEANSER TO PURGE AWAY ANY OF THE PRODUCT LEFT IN THE PUMP COMPONENTS. THIS SHOULD BE CARRIED OUT BY THE PLANT OPERATOR AND A CERTIFICATE OF CLEANLINESS OBTAINED BEFORE STARTING WORK. TO AVOID ANY RISK TO HEALTH IT IS ALSO ADVISABLE TO WEAR PROTECTIVE CLOTHING AS RECOMMENDED BY THE SITE SAFETY OFFICER, ESPECIALLY WHEN REMOVING OLD PACKING WHICH MAY BE CONTAMINATED. Recommended Maintenance Schedule For pump, motor or engine maintenance refer to the separate operators handbooks included within the pump documentation pack. PERIOD Daily Weekly or 100 hours Monthly or 500 hours 6 monthly or 3000 hours Annually or 6000 hours TASK - (Priming equipment only) Drain any water from the coalescer. Check and top up the oil in the Coalescer. Check the tension of the vacuum pump belts. Change the coalescer sump oil. Clean the coalescer sump oil filter mesh Check the valve gear. Clean or renew filter element. Check high capacity filter element. Check the non-return valve ball is seating correctly. Check and if needed renew the vacuum pump drive belt(s). Strip and clean priming tank and valve gear. Check condition of the vacuum pump blades, renew if necessary. Replace the coalescer filter mesh. The above schedule is given for guidance but site-operating conditions may override the suggested maintenance intervals. Adjustments to time scales will also have to be made if the pump is idle for long periods. Page 4

7 Operators Handbook for Manual No/Rev 6.1 Preparation for Maintenance 6.3 Drive Belt Adjustment Electric Shock & Accidental Starting Hazard ISOLATE the equipment before any maintenance work is done. Switch off the main supply, remove fuses, apply lockouts where applicable and affix suitable isolation warning signs to prevent inadvertent reconnection. For diesel driven pumps disconnect the negative battery lead to prevent inadvertent starting. In order to avoid the possibility of maintenance personnel inhaling dangerous fumes or vapours. It is recommended that maintenance work be carried out away from the pump location by removal of the pump unit to a suitable maintenance area. No special tools are required for dismantling and re-assembling, however, it is important to ensure the suitable lifting equipment is available and that the work is carried out in a clean area. 6.2 Coalescer Maintenance Check the oil level in the coalescer tank and drain any water daily. The top of the oil should be level with the underside of the filler cap. Water is removed by means of the drain tap fitted to the side of the coalescer sump. The filter mesh is accessed by removing the coalescer lid and must be cleaned regularly by washing in petrol or a similar spirit. When refitting ensure filter mesh is below exhaust port. The oil feed pipe should be cleaned in a similar manner and blown through with an airline. Belt type Timing belt (toothed) PowerTwist A section link belt Deflection X Force producing deflection X ) 4 mm 1.5 kg 1.6 mm kg To adjust belt tension, loosen the vacuum pump holding nuts and slide the vacuum pump outward. When the correct belt tension is obtained re-tighten holding nuts. Ensure that the pump drive is in line after tightening. Link belt drives can be further adjusted by removing links. ATTENTION DO T OVERTIGHTEN BELTS UNDER ANY CIRCUMSTANCES. For pumps fitted with V belts, it is necessary to disconnect the coupling to replace the belts. For pumps fitted with PowerTwist link belts, the belts can be replaced by slackening the vacuum pump holding down bolts. 6.4 Non-Return Valve The ball should be regularly checked for freedom of movement and absence of debris by inspection through the delivery flange of the valve body. The valve body should be removed to check the seat for damage or wear. 6.5 Vacuum Pump Air Filter Standard Air Filters Air filters are located in the valve cover of the primary tank and should be checked regularly for cleanliness, distortion or damage. Replace if distorted or damaged Air Filter for SY25 Priming Tanks Page 5

8 Manual No/Rev AIR FILTER Operators Handbook for 25PTFLTA Undo the central nut holding the air filter cover and remove to expose the filter element. Air Filter for SY60 Priming Tanks AIR FILTER 60PTFLTA Undo the six nuts holding the top cover and remove the top cover complete to expose the air filter element High Capacity Air Filter SY25 & SY60 vacuum pumps have the option of a high capacity air filter, which is located externally as shown. The high capacity filter is fitted in lieu of the standard element. 60PTVLVA.PCX 25 & 60cfm main valve assembly 6.6 Surge Control Valve On SY25 and SY60 priming tanks a surge control valve is fitted. This should be checked regularly for signs of wear or damage. Components arrowed below are vulnerable to wear and should be replaced if worn excessively. The valve seat should be greased to prevent seizure. 60AFELEA 2 1 Undo the screws holding the retaining cover and remove (1) the cover to inspect the filter. The element pulls out (2). Note that the orientation of the unit should be as shown so that any debris from the filter falls away from the outlet connection when the unit is opened. It can then be easily swept out with little chance of it entering the outlet. Replace the cover O ring when the filter is changed. 6.5 Valve Gear Surge control valve SURGAS1A.PCX Typical main valve assemblies are shown below. The areas arrowed should be checked regularly for wear or damage. Worn parts should be replaced. The main valve is located on the underside of the top cover. Page 6

9 Operators Handbook for Manual No/Rev Section 7 Fault Finding Guide Pump Fails to Prime Disconnect suction hose Blank off suction entry Fit vacuum gauge Are all plugs tight? Reading between kpa ( ft H20)? Check vertical suction lift Type of unit? OTHERS AC 50/75 Is the mini ball valve open? Lift< or = 6.1m (20ft) for AC50/ m (28ft) for AC80/ m (32ft) for others? Test the Vacuum Pump directly Fit Vacuum Gauge Move Pump Reading between kpa ( ft H20)? Is reflux ball seating properly? Are hoses leaking, collapsed or blocked? Is vacuum pressure seal leaking? Is intake blocked? Is oil level correct? Is Vacuum Pump filter blocked? Is impeller blocked? Is belt drive tension OK? Is float gear free and intact? Excessive wear. Remove pump & either overhaul or fit new or exchange Vacuum Pump Is pump casing free from holes? Are all joints sound & leak free? Check impeller wear plate clearances and rectify Is the pump or NRV blocked or damaged? Page 7

10 Manual No/Rev Operators Handbook for Section 8 Supplementary Documents 8.1 General Arrangement Drawing Dimensions are given on ACME Dynamics Drawing No.380/3289, available on request. 8.2 Principles of Operation SUCTION FROM PUMP AIR DRAWN FROM ATMOSPHERE SUCTION FROM PUMP AIR FILTER ANTI-SURGE AIR FILTER ANTI-SURGE N RETURN BALL BACK PRIMING LINE CONTROL BACK FLUSH N RETURN BALL BACK PRIMING LINE CONTROL BACK FLUSH N RETURN DELIVERY N RETURN PRIMARY FLOAT SECONDARY AUTO SECONDARY DUMP AND PIPE PRIMARY FLOAT SECONDARY AUTO SECONDARY DUMP AND PIPE AIR FLOW SUCTION FLOW PACKING IMPELLER PACKING IMPELLER VOLUTE VOLUTE ON INITIAL START - PRIMING SUCTION FROM PUMP AIR FROM PRIMING AIR FILTER ANTI-SURGE N RETURN BALL BACK PRIMING LINE CONTROL PUSH BACK FLUSH OIL FEED TO PUMP AIR VENTED TO ATMOSPHERE N RETURN MESH RETAINING BRACKET PRIMARY FLOAT SECONDARY AUTO SECONDARY DUMP AND PIPE AIR AND OIL RETURN FROM PUMP COALESCER FILTER MESH OIL FILLER CAP BACKFLUSH FLOW PACKING SY-Prime4.cdr IMPELLER VOLUTE BACK FLUSH OPERATION SYCoas1.CDR RESTRICTED ORIFICE (3/32") PUMP & COALESCER WATER DRAIN TAP OIL FEED FILTER Page 8

11 Operators Handbook for Manual No/Rev 8.4 Spare Parts Spare parts information is available from the Spare Parts Book No. W77-004E ACME Dynamics, Inc. operate a comprehensive Spares and Service support network throughout the world, and can be contacted as follows: SPARES & SERVICE Telephone: (800) For spare parts, supply only. For breakdowns, spare parts and, on-site fitting, pump installation and, commissioning, and service contracts. Ask for - Parts Dept. ask for - Service Dept. Spares & Service Office ACME Dynamics, Inc. General Fax line: (813) P. O. Box 1780 Plant City, FL Copies of this manual are available from the ACME Dynamics, Inc. Parts & Service Department by quoting the manual reference number. W78-001E Page 9

DECLARATION OF CONFORMITY OR DECLARATION OF INCORPORATION

DECLARATION OF CONFORMITY OR DECLARATION OF INCORPORATION DECLARATION OF CONFORMITY OR DECLARATION OF INCORPORATION We SPP Pumps Limited Of Theale Cross Reading Berkshire England RG31 7SP Declare that: Equipment: Model/Type: Serial Number: CENTRIFUGAL PUMP EUROSTREAM

More information

AUTOPRIME XH RANGE OF EXTRA HEAD CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS. Types XH100, XH150 and XH 200

AUTOPRIME XH RANGE OF EXTRA HEAD CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS. Types XH100, XH150 and XH 200 AUTOPRIME XH RANGE CENTRIFUGAL PUMPS OPERATORS INSTRUCTIONS AUTOPRIME XH RANGE OF EXTRA HEAD CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS Types XH100, XH150 and XH 200 SPP Pumps Limited

More information

DP RANGE PUMP END KITS WITH DYNAPRIME - LOW EMISSIONS MECHANICAL PRIMING

DP RANGE PUMP END KITS WITH DYNAPRIME - LOW EMISSIONS MECHANICAL PRIMING DP RANGE PUMP END KITS OPERATORS INSTRUCTIONS AND PART BOOK DP RANGE PUMP END KITS WITH DYNAPRIME - LOW EMISSIONS MECHANICAL PRIMING ACME Dynamics, Inc. P. O. Box 1780 Plant City, FL 33564-1780 3608 Sydney

More information

GUIDE TO THE INSTALLATION OF SPP PUMPS

GUIDE TO THE INSTALLATION OF SPP PUMPS PUMP INSTALLATION GUIDE GUIDE TO THE INSTALLATION OF SPP PUMPS SPP Pumps Limited. Theale Cross Reading Berkshire ENGLAND RG31 7SP Telephone: +44 (0)1189 323123 Fax: +44 (0)1189 323302 Document No: W00-002E

More information

Unistream Pumps UNISTREAM RANGE CENTRIFUGAL PUMP OPERATORS INSTRUCTIONS ++44(0) (0) Telephone: Fax:

Unistream Pumps UNISTREAM RANGE CENTRIFUGAL PUMP OPERATORS INSTRUCTIONS ++44(0) (0) Telephone: Fax: UNISTREAM RANGE CENTRIFUGAL PUMP OPERATORS INSTRUCTIONS Unistream Pumps SPP Pumps Limited Theale Cross Reading Berkshire ENGLAND RG31 7SP Telephone: ++44(0) 1189 323123 Fax: ++44(0) 1189 323302 Document

More information

SF RANGE OF CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS

SF RANGE OF CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS SF RANGE OF CENTRIFUGAL PUMPS FOR VACUUM ASSISTED SELF PRIMING APPLICATIONS Types SF200, SF250, SF300 and SF400 ACME Dynamics, Inc. P.O. Box 1780 Plant City Florida 33564 Telephone: 813-752-3137 Fax: 813-752-4580

More information

RANGE OF DIESEL DRIVEN MOBILE PUMPSETS

RANGE OF DIESEL DRIVEN MOBILE PUMPSETS SERIES PUMP OPERATORS HANDBOOK RANGE OF DIESEL DRIVEN MOBILE PUMPSETS ACME Dynamics, Inc. P. O. Box 1780 Plant City, FL 33564-1780 Telephone: (800) 622-9355 Document No:. W72-008E Revision No:... 5 Revision

More information

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 -

Air Compressor. Operating & Maintenance Instructions 1110 ENGINE DRIVEN - 1 - Air Compressor ENGINE DRIVEN Operating & Maintenance Instructions 1110-1 - Read these safety instructions before using the equipment. INTRODUCTION Thank you for purchasing this Clarke portable compressor.

More information

INSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA

INSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA INSTRUCTION MANUAL: Industrial Series Piston Air Compressor Model Number: V8051-335 Part Number: L001128KNA Pump Model: LP335 K335 Motor: 5 HP / 1 PH Air Tank: 80 Gal Vertical 1830 W. 15 th St. Houston,

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

Routine Compressor Maintenance

Routine Compressor Maintenance Establishing a regular, well-organized maintenance program and strictly following it is critical to maintaining the performance of a compressed air system. One person should be given the responsibility

More information

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump Installation, Operating, Maintenance and Safety Instructions JABSCO 53040 & 5304-Series 40 SIZE UTILITY Pump TO OBTAIN THE BEST PERFORMANCE FROM YOUR JABSCO PUMP PLEASE READ THESE INSTRUCTIONS CAREFULLY

More information

Gear pump manual for foam pelton wheel driven pumps

Gear pump manual for foam pelton wheel driven pumps Albany Pumps AN EMPLOYEE OWNED COMPANY OPERATING AND MAINTENANCE Gear pump manual for foam pelton wheel driven pumps THIS MANUAL SHOULD BE USED ALONGSIDE THE ALBANY STANDARD INSTALLATION, OPERATION AND

More information

INSTRUCTION MANUAL (original instructions) K2, K3

INSTRUCTION MANUAL (original instructions) K2, K3 IMPORTANT DOCUMENT Please pass to Maintenance Department MDM PUMPS LTD Spring Lane Malvern Worcs WR14 1BP England Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: info@mdmpumps.co.uk www.mdmpumps.co.uk

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

BLACKMER BYPASS VALVES

BLACKMER BYPASS VALVES BLACKMER BYPASS VALVES INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EBSRAY MODEL: RV18 RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19 967020 INSTRUCTIONS NO. 551-E00 Section Effective Replaces

More information

JABSCO & Series 1½ 80 SIZE UTILITY Pump

JABSCO & Series 1½ 80 SIZE UTILITY Pump DOC271/98/01 Installation, Operating, Maintenance & Safety Instructions for JABSCO 53080 & 53081-Series 1½ 80 SIZE UTILITY Pump TO OBTAIN THE BEST PERFORMANCE FROM YOUR JABSCO PUMP PLEASE READ THESE INSTRUCTIONS

More information

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1 26 - COOLING SYSTEM CONTENTS Page LAND ROVER V8 DESCRIPTION AND OPERATION ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 FAULT DIAGNOSIS COOLING SYSTEM FAULTS... 1 REPAIR COOLANT - DRAIN

More information

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF CONVEYORS EASIKIT 300 EASIKIT 450 EASIKIT 600, 900, 1200 & 1500 The manufacturer does not accept responsibility for any loss, damage to other equipment,

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

FULL OPERATING AND MAINTENANCE MANUAL

FULL OPERATING AND MAINTENANCE MANUAL Enter Serial No. here. In the event of an enquiry please quote this serial number. www.monoequip.com FULL OPERATING AND MAINTENANCE MANUAL FOR THE STAND ALONE DIVIDER FG398 Stand alone divider REV.A17

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

Air Compressor. Models: CFP9HND. Operating & Maintenance Instructions

Air Compressor. Models: CFP9HND. Operating & Maintenance Instructions Air Compressor Models: CFP9HND Operating & Maintenance Instructions 0614 - 2 - WARNING! DO NOT ATTEMPT TO ALTER ENGINE SPEED SETTINGS DOING SO WILL INVALIDATE YOUR GUARANTEE SPECIFICATIONS CFP9ND Part

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

PARTS MANUAL SERIES PUMPSETS FOR. DYNAPRIMEem SERIES PARTS BOOK. Telephone: (800) Fax: (813)

PARTS MANUAL SERIES PUMPSETS FOR. DYNAPRIMEem SERIES PARTS BOOK. Telephone: (800) Fax: (813) DYNAPRIMEem SERIES PARTS MANUAL FOR SERIES PUMPSETS ACME Dynamics, Inc. P. O. Box 1780 Plant City, FL 33564-1780 Telephone: (800) 622-9355 Document No:. W72-013E Revision No:... 3 Revision Note No:. R

More information

SUPERHONE Installation * Operation * Maintenance * Replacement Parts

SUPERHONE Installation * Operation * Maintenance * Replacement Parts SUPERHONE Installation * Operation * Maintenance * Replacement Parts I.C.M., Inc. 10630 South Garfield Avenue South Gate, CA 90280-7395 Telephone: 562/869-3004 888/351-2570 Fax: 562/869-3005 Website: www.icm2000.com

More information

AP50 MANUAL AND PARTS LIST VERSA-MATIC PUMP. Service / Maintenance Log SUBMERSIBLE CENTRIFUGAL PUMP. Contact Information. Date Details Completed

AP50 MANUAL AND PARTS LIST VERSA-MATIC PUMP. Service / Maintenance Log SUBMERSIBLE CENTRIFUGAL PUMP. Contact Information. Date Details Completed Service / Maintenance Log Date Details Completed MANUAL AND PARTS LIST AP50 SUBMERSIBLE CENTRIFUGAL PUMP Contact Contact Information Phone / Fax No. DISTRIBUTOR VERSA-MATIC PUMP A Unit of IDEX Corporation

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS (27/6/13) Contents 1. GENERAL DESCRIPTION... 2 2. RECEIPT AND PREPARATION... 2 3. INSTALLATION... 2 3.1. REMOVAL OF ACCESS PANEL... 2 3.2. FIXING A PLINTH...

More information

SYDEX / MAINTENANCE AND OPERATION MANUAL

SYDEX / MAINTENANCE AND OPERATION MANUAL Installation Operation and Maintenance Attention: The following explanations have the aid to give you all possible information over the SYDEX pumps range. The right choosing of the pump is depending from

More information

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS (Rev. 2.0_10-2010) DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS TRVK 2003 to 5003 TRSK 2005 to 5005 INTRODUCTION These instructions are for the maintenance staff in case of repair

More information

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd CBS Products (KT), Ltd, Pillings Road, Oakham, Rutland, LE15 6QF. UK Telephone: +44(0)1572723665 Fax: +44(0)1572 756006 E-Mail: sales@cbsproducts.com Website:www.cbsproducts.com OPERATING MANUAL C-1350

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instructions 6101794 / 10.08.2017 / 1-9 Instruction and Maintenance Manual Self-priming Centrifugal Pumps Type S Index A. Declaration of Conformity 2 B. Introduction 3 C. Operation 5 D. Automatic Grease

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps 4100 Series Operating Manual Contents: Model Number/Serial Number Pg. 1 Safety Information Pg. 2 Operating Instructions

More information

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16 USER INSTRUCTIONS NAF Setball SF Ball Sector Valves FCD NFENIM4156-00 A4 09/16 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4

More information

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE DB

INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE DB INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE DB KIRLOSKAR BROTHERS LIMITED UDYOG BHAVAN, TILAK ROAD, PUNE - 4 002 KIRLOSKAR BROTHERS LIMITED Udyog Bhavan, Tilak Road,

More information

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions 3579049/14 IM-P357-29 CTLS Issue 14 PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions PN9100 PN9200 1. Safety information 2. General product information PN9300 3. Installation

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instructions 6101794 / 12.03.2010 / 1-9 Instruction and Maintenance Manual Self-priming Centrifugal Pumps Type S Index A. Declaration of Conformity 2 B. Introduction 3 C. Operation 5 D. Automatic Grease

More information

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List LOG CHOP Hydraulic Wood Guillotine Owners Illustrated Instruction Book & Parts List Grovebury Road, Leighton Buzzard, Bedfordshire. LU7 4UX. UK. Tel:01525 375157. Fax:01525 385222. Email: enquires@brownsagricultural.co.uk

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL COLD WATER PETROL WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Intelligent Flow Measurement Your Sole Source for Badger Differential Producers Worldwide 6 Blackstone Valley Place, Lincoln RI 02865-1162 Ph: 401 334 1170 Fx: 401 334 1173 Em: solutions@wyattflow. Installation,

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve... Priming Systems Installation Priming Systems Operation & Maintenance Form No. F 1031 Section 2312 Issue Date 10/07/94 Rev. Date 02/27/06 Table of Contents Illustrations Principals of Operation...........................

More information

SERIES G3DB/AG3DB ELEVATOR

SERIES G3DB/AG3DB ELEVATOR TM INSTRUCTIONS AND PARTS LIST SERIES G3DB/AG3DB ELEVATOR WARNING This manual, and GENERAL INSTRUCTIONS MANUAL, CA-1, should be read thoroughly prior to pump installation, operation or maintenance. SRM00059

More information

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Date of Issue: 04 August 2010 Page 1 of 27 QF 80: Issue 2 WARNING! BEFORE ANY INSTALLATION AND MAINTENANCE WORK CAN COMMENCE ENSURE THE VALVE AND SURROUNDING

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

More information

DIAPHRAGM PUMPS: Instruction Manual

DIAPHRAGM PUMPS: Instruction Manual INTRODUCTION DIAPHRAGM PUMPS: Instruction Manual Congratulations for choosing a product Imovilli Pompe, the result of a careful manufacturing process supported by over fifty years of specific experience

More information

WARNING. Before the exhaust silencer is fitted to the pump, the pump must be secured as describe in the pump manual. WARNING

WARNING. Before the exhaust silencer is fitted to the pump, the pump must be secured as describe in the pump manual. WARNING 5 Exhaust silencer WARNING Before the exhaust silencer is fitted to the pump, the pump must be secured as describe in the pump manual. WARNING The exhaust silencer must be removed from the pump before

More information

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15 USER INSTRUCTIONS NAF Trunnball DL Ball Valves FCD NFENIM4168-01-A4 01/15 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4 4 Installation

More information

Air Compressor PP10ND PPH10ND PP15ND PPH15ND. Operating & Maintenance Instructions

Air Compressor PP10ND PPH10ND PP15ND PPH15ND. Operating & Maintenance Instructions Air Compressor PP10ND PPH10ND PP15ND PPH15ND Operating & Maintenance Instructions 1002 SPECIFICATIONS PP10ND PPH10ND PP15ND PPH15ND Part Number 2090940 2090960 209080 2090100 WARNING! DO NOT ATTEMPT TO

More information

Instruction Manual. E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps. Item Number

Instruction Manual. E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps. Item Number Instruction Manual A344-02-880 Issue J Original E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps www.idealvac.com (505)872-0037 Description Item Number Description Item Number E1M40,

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

Chapter 4 Part D: Exhaust and emission control systems

Chapter 4 Part D: Exhaust and emission control systems 4D 1 Chapter 4 Part D: Exhaust and emission control systems Contents Air inlet heating system components - removal and refitting...... 4 Catalytic converter - general information and precautions........

More information

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport,

More information

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual RIGID PENDANT Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K.,

More information

BELT CONVEYOR CB/M5 Series

BELT CONVEYOR CB/M5 Series BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine

More information

Thank you for selecting the GD submersible grinder pump.

Thank you for selecting the GD submersible grinder pump. GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6

More information

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES TABLE OF CONTENTS GENERAL SERIES 854(TYPICAL EXPLODED VIEW) COMPONENT LIST INTRODUCTION TO AVK/GLENFIELD SERIES

More information

DYNAPAC CONCRETE EQUIPMENT RAMIRENT. BG70 Power Floats INSTRUCTIONS & SPARE PARTS CATALOGUE BG70 - IS ENG

DYNAPAC CONCRETE EQUIPMENT RAMIRENT. BG70 Power Floats INSTRUCTIONS & SPARE PARTS CATALOGUE BG70 - IS ENG DYNAPAC CONCRETE EQUIPMENT INSTRUCTIONS & SPARE PARTS CATALOGUE BG70 Power Floats BG70 - IS - 10682 - ENG SAFETY INSTRUCTIONS - MACHINES SUBMITTED : Powered with : Electric, Pneumatic, Petrol or Diesel

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

Sheet Metal Shear. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Sheet Metal Shear. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING

More information

HUGH CRANE. SOUTH WALSHAM ROAD, ACLE, NORWICH, NORFOLK, NR13 3ES TEL: FAX:

HUGH CRANE. SOUTH WALSHAM ROAD, ACLE, NORWICH, NORFOLK, NR13 3ES TEL: FAX: HUGH CRANE Cleaning Equipment Limited SOUTH WALSHAM ROAD, ACLE, NORWICH, NORFOLK, NR13 3ES TEL: 01493 750072 - FAX: 01493 751854 - www.hughcrane.co.uk FS0962 OPERATOR INSTRUCTION MANUAL COMMANDO 500P For

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

Instruction Manual. EH Mechanical Booster Pumps. A Issue M

Instruction Manual. EH Mechanical Booster Pumps. A Issue M A301-51-880 Issue M Instruction Manual EH Mechanical Booster Pumps Manor Royal, Crawley, West Sussex, RH10 2LW, UK Telephone: +44 (0) 1293 528844 Fax: +44 (0) 1293 533453 http://www.bocedwards.com CONTENTS

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

APT10-2 Automatic Pump Trap

APT10-2 Automatic Pump Trap 6120050/3 IM-P612-18 ST Issue 3 APT10-2 Automatic Pump Trap Installation and Maintenance Instructions 1. General safety information 2. Product information 3. Installation Closed loop steam systems only

More information

HIGH PRESSURE FUEL PUMP 1

HIGH PRESSURE FUEL PUMP 1 2010 X250, 303-04 FUEL CHARGING AND CONTROLS - V8 5.0L PETROL HIGH PRESSURE FUEL PUMP 1 (G1185928) REMOVAL AND INSTALLATION 19.45.30 HIGH PRESSURE FUEL PUMP FRONT RENEW 5000 CC, AJ V8, NATURALLY ASPIRATED

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

TANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO

TANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO TANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO WWW.MARSHALL-TRAILERS.CO.UK FOR MODELS: ST1200, ST1400, ST1600, ST1800, ST2000, ST2300, ST2550 CHARLES J. MARSHALL (ABERDEEN) LTD CHAPEL WORKS,

More information

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual TABLE OF CONTENTS Introduction 3 Precautions & Maintenance 4-5 Piston pump Care & Maintenance 5-6 Shut Down & Winterizing 6 Troubleshooting

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Turbocharger / VTR..0, VTR..1 Original assembly instructions English Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,

More information

Impeller Replacement

Impeller Replacement Impeller Replacement Threaded Shaft Frame Mount H 806 Clockwise Rotation Volute shown. 1149 0794 1 Unfasten hardware holding volute to bracket. Remove volute to expose impeller. Peel off old volute gasket

More information

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS WARNING This Instruction Manual and General Instructions Manual, CA-1, should be read thoroughly prior to pump installation,

More information

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL SRM00046, should be read thoroughly prior to pump installation, operation or maintenance. Manual No. SRM00095

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

GL Ludemann Y-Strainers

GL Ludemann Y-Strainers GL Ludemann Y-Strainers Installation, Operation and Maintenance Manual English Issue 1-03/2014 - Page 1/7 GENERAL These instructions are for installing, operation and maintenance of Y-strainers fabricated

More information

QLM and QLD Series DN125 to DN200 Three Port Control Valves

QLM and QLD Series DN125 to DN200 Three Port Control Valves 3.63.27.22 3900/1 IM-P39-1 CH Issue 1 QLM and QLD Series DN12 to DN200 Three Port Control Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

APT14 Automatic Pump Trap Installation and Maintenance Instructions

APT14 Automatic Pump Trap Installation and Maintenance Instructions 6120250/7 IM-P612-04 ST Issue 7 APT14 Automatic Pump Trap Installation and Maintenance Instructions 1 Product information 2 Operation 3 Installation Closed loop steam systems only 4 Commissioning 5 Maintenance

More information

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

PRODUCT OPERATING MANUAL

PRODUCT OPERATING MANUAL PRODUCT OPERATING MANUAL PANBLAST TM PROFLO ABRASIVE RECYCLING SYSTEM Manual Number: ZVP PC 0035 01 SECTION 1. GENERAL INFORMATION 2. ASSEMBLY INSTRUCTIONS 3. OPERATING INSTRUCTIONS 4. MAINTENANCE 5. TROUBLE

More information

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 TRUCKS FOOD OFFSHORE FISH SAMSON LIQUID RING VACUUM PUMPS INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 DOC3700C INDUSTRY GAMMA UNITS 2 CONTENTS 1

More information

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS PRODUCT SERVICE MANUAL BK6DHZ(C)-250, 275, 312 and 400 PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL, SRM00046, should be read thoroughly prior to pump installation, operation or maintenance.

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information