Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Size: px
Start display at page:

Download "Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM"

Transcription

1 Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial Flow Pumps have a high-precision and rigid structure with outstanding performance and are manufactured based on our technologies gained through years of experience. Since our products are carefully inspected before delivery, we are confident that you can use them with your mind at ease. Furthermore, make use of this instruction manual to fully deliver the excellent performance of Teral s Submersible Mixed Flow/Axial Flow Pump. Upon receiving the pump, check the following points first: Check the nameplate to verify that the model name, pump head, discharge rate, revolution speed, motor output, voltage, frequency, and other information are exactly what you ordered. No part of the unit including cables is damaged during transportation. All bolts and nuts are firmly tightened. All the accessories that you ordered have been delivered. If you find any problems, contact the vendor from which you purchased the product. To the customers Instruct the vendor (installation contractor) to install the pump. Thoroughly read this manual and properly use the pump. Keep this manual carefully after use, and read it when needed. Note that we are not liable for any product failures or accidents caused by improper use. To the vendors (installation contractor) Properly install the pump according to this manual. On completion of the installation, be sure to submit this manual to the customer. Note that we are not liable for any product failures or accidents caused by improper installation or improper use. Contents Instruction Manual for the customer Safety precautions (Be sure to observe the following.)... 1 Instructions for proper use... 3 Troubleshooting... 4 After-sales service... 4 Installation Manual for the vendor (installation contractor) Safety precautions (Be sure to observe the following.) Instructions before installation (1) Cleaning the pit... 7 (2) Power voltage... 7 (3) Motor... 7 (4) Installation places to be avoided Instructions during installation (1) Checking the submersible cable... 8 (2) Installing the pump... 8 (3) Grounding... 8 (4) Role of the control panel... 8 (5) Installation places of the operation panel to be avoided Operation (1) What you need to know before operation... 9 (2) Operations before starting the pump... 9 (3) Starting the pump... 9 (4) Cautions during the operation... 9 (5) Caution when the pump is stopped (6) Trouble and the causes Teral Inc.

2 Instruction Manual Safety precautions Be sure to observe the following. The user must observe the following instructions in order to prevent personal injury and property damage. The following symbols and labels are used to indicate the severity of the injuries and damage that may result from improper use or work in defiance of the instructions. WARNING CAUTION indicates that incorrect handling may lead to death or severe injury. indicates that incorrect handling may lead to injuries or property damage. The following symbols indicate the types of instructions to be observed. (The following are only part of all the symbols.) This graphic symbol indicates prohibited actions that must NOT be done. This graphic symbol indicates mandatory actions that must be done. WARNING Never disassemble, repair, or modify the product. Do not operate the control panel, ground fault interrupter, or other electric devices with wet hands. Do not disassemble It may lead to ignition or malfunction, thus causing injuries. For repairs, contact the vendor (installation contractor). It may lead to an electric shock. Do not damage the submersible cable, apply an excessive force to it, or bundle it. If the submersible cable or above-ground wires are damaged, do not use the product. It may lead to a fire or electric shock. It may lead to a fire or electric shock. Instruct the vendor (installation contractor) to repair them. Do not put anything heavy on the submersible cable or above-ground wires, pinch them, or rework them. It may damage the submersible cable or above-ground wires, thus leading to a fire or electric shock. 1

3 WARNING Do not use the product with the door of the control panel open. Rainwater or dust gets into the control panel, and resulting insulation degradation or other problems may lead to an electric shock or fire. Do not perform zero-discharge operation for more than 10 minutes. Do not put anything inside the control panel. Resulting overheat may lead to ignition and a fire. Do not run the product in mud. It may lead to hot water, an electric shock, injury, or accident. It may lead to an electric shock or accident. Do not fix the position of the reset button of the motor protective relay with tape or other means. In the event of a failure, the motor or wires may be overheated, thus leading to ignition and a fire. If the motor protective relay is tripped, contact the vendor (installation contractor). Ensure to turn off the power before starting maintenance or inspection work. It may lead to an electric shock or injury. CAUTION Do not open the door of the control panel. Never run the pump dry (operation without any water being pumped out). It may lead to an electric shock or accident. It may lead to a fire, electric shock, or accident. If the product is not working properly, immediately turn off the power and contact the vendor (installation contractor). If no water flows out, immediately turn off the power and contact the vendor (installation contractor). 2

4 Instruction Manual Safety precautions Be sure to observe the following. CAUTION If you do not use the product for a long time, be sure to turn off the power. It may lead to insulation degradation, thus resulting in an electric shock; or it may lead to an electric leak, thus resulting in a fire. If the product does not run or if there is anything wrong with it, immediately turn off the power. It may lead to an electric shock, electric leak, or short circuit, thus resulting in a fire. Ensure to instruct the vendor (installation contractor) to inspect and repair the product. Instructions for proper use Pay attention to the discharge rate. The discharge rate may suddenly decrease if air is drawn from the strainer (suction port) or if the strainer is clogged with dirt. In such a case, contact the vendor (installation contractor). Pay attention to the needle of the ammeter. If the deflection of the meter needle is large or the operating current exceeds the rated value, contact the vendor (installation contractor). Close the cock of the compound pressure gauge. Leaving the cock open may damage the compound pressure gauge by a shock during startup or stop. If no water has been pumped out for over 3 or 4 days, open the water tap to run water for a while before use. In such a case, water inside the pump and piping may be cloudy. Even if you do not plan to use the pump for a long time, run it periodically (once a month or so). For maintenance and safety, it is recommended to check the insulation resistance and operating conditions (electric current, vibration, discharge rate, etc.) periodically (once a month or so). Contact the vendor (installation contractor). 3

5 Ensure to confirm the following installation points from the vendor (installation contractor). If the product is for indoor use, confirm that measures are taken against water leakage. If water flows out during repairs or inspection or in the event of a failure, it may drench surrounding areas or downstairs, thus leading to serious compensation issues. Check that no ground wire is connected to a gas pipe or water pipe. It may lead to an explosion or electric shock. Confirm that the product is securely grounded and that the dedicated ground fault interrupter is installed. It may lead to an electric shock in the event of a failure or electric leak. (You are required by law to connect a ground wire.) Check that measures are taken against freezing of the above-ground section and the pipe. Even in a warm region, an unexpected cold wave may freeze and damage the above-ground section and piping in winter. Troubleshooting If there is a problem, carry out troubleshooting according to the following table. If the problem still persists, contact the vendor (installation contractor). Problem Possible Cause Action No rotation of motor (The motor does not run.) The motor is running, but no water flows out, or the discharge rate is low. The power supply (ground fault interrupter) is shut off. The sluice valve of the above-ground section or a valve installed in the pipe is closed. Turn on the power (ground fault interrupter). Open the sluice valve and other closed valve(s) in the pipe. After-sales service For repair, handling, maintenance, and other work of the product, contact the vendor from which you purchased the product. Before instructing the vendor to repair the product, check the items shown in the Troubleshooting on this page. If the problem still persists, first turn off the power and the ground fault interrupter, and then contact the vendor (installation contractor) from which you purchased the product. 4

6 Installation manual Safety precautions Be sure to observe the following. The installation worker must observe the following instructions in order to prevent personal injury and property damage. The following symbols and labels are used to indicate the severity of the injuries and damage that may result from improper use or work in defiance of the instructions. WARNING CAUTION indicates that incorrect handling may lead to death or severe injury. indicates that incorrect handling may lead to injuries or property damage. The following symbols indicate the types of instructions to be observed. (The following are only part of all the symbols.) This graphic symbol indicates prohibited actions that must NOT be done. This graphic symbol indicates mandatory actions that must be done. WARNING Do not connect the ground wire to a gas pipe or water pipe. Do not operate the control panel, ground fault interrupter, or other electric devices with wet hands. It may lead to an explosion or electric shock. It may lead to an electric shock. Do not use the submersible cable for above-ground wiring. Use it for the connection of only up to the conduit, terminal box, etc. Do not damage the submersible cable, apply an excessive force to it, or bundle it on the ground. Resulting overheat may lead to ignition and a fire. It may lead to a fire or electric shock. Do not use the product at any voltage other than specified. It may lead to a fire or electric shock. Cut off any excess of the submersible cable above the ground, and connect the cable to the control panel or the terminal box. 5

7 WARNING Do not use the product for pumping any liquid other than clean water (salt water, oil, chemicals, etc.) or for pumping hot water above 40 C. It may lead to an explosion, fire, electric shock, or accident. Carry out installation work safely and securely. Problems such as the fall of the pump may occur, thus leading to an injury. Furthermore, improper work may cause water leakage, an electric shock, or a fire. Only specialist contractors are allowed to carry out the installation work. Carry out wiring work safely and securely according to the technical standards for electrical facilities, as well as the indoor wiring regulations. Improper wiring work may cause an electrical shock or a fire. Only licensed electrical engineers are allowed to carry out electrical wiring work. Ensure to install a ground fault interrupter. It may lead to an electric shock in the event of a failure or electric leak. (You are required by law to install a ground fault interrupter.) In the event of an electric leak, the interrupter immediately shuts off the power, thus preventing an electric shock. Ensure to turn off the power before grounding work. It may lead to an electric shock. Ensure to connect a ground wire (Class D grounding). Connect a ground wire It may lead to an electric shock in the event of a failure or electric leak. (You are required by law to connect a ground wire.) Connect a ground wire to the ground terminal of the well lid, and bury the ground rod in the ground. Only licensed electrical engineers are allowed to carry out the grounding work according to the technical standards for electrical facilities. 6

8 Installation manual 1. Instructions before installation (1) Cleaning the pit If the pit is not cleaned thoroughly, the suction port and strainer of the pump may get clogged with debris (such as wood pieces, bolts, nuts, iron pieces, gravel, concrete pieces, or rags) left in the pit, which significantly reduces the discharge rate and compromises its performance. Because running the pump in that condition may damage the pump, be sure to clean the inside of the pit before installation and take measures to prevent the entry of any debris or dirt into the pump, for example, by installing a screen on the suction port. (2) Power voltage a. Keep the voltage applied to the motor within ±10% of the rated voltage during the operation. b. If you need to connect an extra cable to the supplied cable for extension, use a cable thick enough to keep a voltage drop across the cable within 5% of the rated voltage during the operation. Do not allow the joint of the cables to be submerged in water. c. Keep the voltage imbalance between each phase within ±2.5%. (3) Motor a. Before shipment, antifreeze solution has been filled in the motor at our factory. Upon installing the pump, be sure to take the following steps to check whether the filled solution has leaked during the transportation: [1] Place the motor on its side. [2] Remove the plugs of the filler port and drain port located on the side in the upper section of the motor. [3] Check the level of the solution. [4] If the solution is insufficient, add clean water. Caution label Filler port plug, drain port plug (one for each) Pump strainer Submersible motor When you add clean water (you may use tap water), ensure that no air is trapped in the motor. Note that any residual air may cause the bearing or other parts of the motor to burn out. b. Never run the motor on the ground. Ensure to run the motor only after it is submerged in water. c. Handle both the motor section and the pump section with care. Pay special attention not to allow the unit to topple over or fall. d. If you need to lift the motor out of water and store it, remove the drain plug from the bottom of the motor and completely drain water before storage. Particularly when you store the motor at a place that could be exposed to the freezing temperature, be sure to drain water because otherwise the motor frame and other parts will be damaged. (4) Installation places to be avoided a. Places with a large amount of sand or debris b. Places exposed to corrosive substances c. Avoid pumping warm or hot water. d. Places exposed to sea water or salt 7

9 Installation manual 2. Instructions during installation (1) Checking the submersible cable Before and after installing the cable, be sure to measure its insulation resistance and continuity. Although this product including the submersible cable is strictly tested and inspected before shipment, check for any flaws or damage and measure the insulation resistance before installation, just in case. Be careful not to damage the submersible cable during the installation work, and measure the insulation resistance and continuity again after the installation. If the insulation resistance is 1MΩ or less, contact the vendor from which you purchased the product. (2) Installing the pump a. This product can be suspended or mounted for use. In either case, install supporting devices at necessary points. The supporting devices must be large and strong enough to support the weight of the pump, its accessories, lifting pipe, and pumping water as well as to absorb various vibrations and shocks to be generated during the operation. b. Ensure to install a check valve in the discharge piping. Otherwise, back flow occurs when the pump has stopped, which causes the pump to rotate in the reverse direction and significantly shortens the service life of the pump. Also install a sluice valve and a compound pressure gauge in order to control the water flow rate and for future inspection. Note: If you use a sluice valve together with the Axial Flow Pump, refer to the section 3.(2)-a. Operations before starting the pump on page 9. (3) Grounding Ground the product so that 100Ω or lower grounding resistance can be achieved (Class D grounding). For grounding, use copper wire with the diameter (thickness) specified in the following table. Capacity of motor Up to 2.2 kw Up to 3.7 kw Up to 7.5 kw Up to 15 kw Up to 37 kw Over 37 kw Wire thickness 1.6 mm (2.0 mm 2 ) or greater 2.0 mm (3.5 mm 2 ) or greater 2.6 mm (5.5 mm 2 ) or greater 14 mm 2 or greater 22 mm 2 or greater 38 mm 2 or greater (4) Role of the operation panel The most essential role of the operation panel is to prevent motor burnout. The submersible motor pump runs under water, and the only way to conduct a diagnosis on the ground is through the operation panel. Therefore, the operation panel must be highly reliable. The operation panel specified by Teral has been manufactured exclusively for use in the submersible motor pumps. It protects the pump and allows the user to start and stop the pump through simple operations. (5) Installation places of the operation panel to be avoided Avoid installing the operation panel at the following places: a. Places exposed to vibrations b. Hot or humid places c. Places exposed to water (rain, snow) (for indoor-type) d. Places with a possible ignition source e. Places with a possible generation of a corrosive gas f. Dusty or dirty places g. Places exposed to direct sunlight (for indoor-type) 8

10 Installation manual 3. Operation (1) What you need to know before operation a. Criteria for determining whether the rotation direction is normal or reverse If water is pumped up with the valve fully open, the motor is running in the normal direction. If the motor is running in the reverse direction, a significantly smaller amount of water will be pumped up, accompanied by a noise and vibration. Therefore, you can tell whether the motor is running in the normal or reverse direction. b. How to make the motor run from the reverse to normal direction Direct on-line starting Terminals on control panel Star-delta starting Terminals on control panel To main switch To motor To main switch To motor Swap V with W. Swap V1 with W1, and W2 with U2. (2) Operations before starting the pump a. Because of its characteristics, running the Mixed Flow/Axial Flow Pump with its sluice valve fully closed leads to overcurrent. Fully open the valve before turning ON the (start) switch. b. If the compound pressure gauge is used, keep the cock of the gauge closed. Otherwise, the shock applied during the startup may damage the gauge. (3) Starting the pump a. Turn ON the (start) switch. b. When water flows out, check the rotation direction of the pump (i.e., normal or reverse). If the pump produces a noise and vibration and the water pressure is significantly lower than the specified pressure, the motor is running in the reverse direction. Change the rotation to the normal direction in such a case, referring to the section 3.(1) What you need to know before operation on page 9. Be aware that running the pump in the reverse direction is not only highly inefficient, but may also cause damage to both the pump and motor. (4) Cautions during the operation a. Pay attention to the discharge rate. If the suction water level becomes abnormally low during the operation and that allows the entry of air from the suction port (the strainer), the pumping function may get compromised in terms of both efficiency and discharge rate and it may also cause the vibration of the pump. Furthermore, the strainer may get clogged with debris, leading to a sudden decrease in the discharge rate. Therefore, be sure to install a screen on the suction port to prevent the entry of debris. b. Pay attention to the needle of the ammeter. In the case described in the above caution (a.), the electric current decreases. If debris (such as sand) is caught in the sliding part of the impeller or in other parts, the needle shows a large deflection or the operating current exceeds the rated value. 9

11 (5) Caution when the pump is stopped In the event of a power failure during the operation, be sure to turn off the main switch. (6) Trouble and the causes Trouble with the pump and motor can result from a variety of causes and the actions are different accordingly; but in any case it is essential to identify the symptom and take actions at an early stage. The following table lists typical examples of symptoms and their causes. Refer to the table and take appropriate actions. If you have anything unclear, ask the vendor from which you purchased the product. Troubleshooting table Cause Symptom Difficulty in starting the pump Vibration Noise Overload Too little load Low discharge rate Low pump head Unable to pump up water Large deflection of ammeter needle Tripping of the auto stop protection device Reverse rotation Voltage drop The sluice valve is half-opened or closed. Wrong installation of the check valve Low water level Axial Flow Axial Flow Axial Flow Clogging at the strainer on the suction port The impeller eye is clogged with debris. Debris is caught in the impeller s sliding part. Wear of the impeller s sliding part Contact of a rotating part with another part, and its seizure Single-phase operation Insulation degradation (cable sheath, flaws, broken wire) 10

12 Head Office 230, Moriwake, Miyuki-cho, Fukuyama-city, Hiroshima, , Japan Tel Fax

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Instruction Manual Installation Manual Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Thank you for your purchase of Teral (Volute) Submersible Turbine Pump. To the customers

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD. 17236733/B-10011-5 LSC Submersible Residue Dewatering Pump LSP Self-Priming Residue Dewatering Pump OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD. INTRODUCTION Thank you for selecting the Tsurumi LSC

More information

Coolant Pump. Instruction Manual. Coolant Pump. Model : LBK-MR-e. Original Instructions

Coolant Pump. Instruction Manual. Coolant Pump. Model : LBK-MR-e. Original Instructions Coolant Pump Instruction Manual Coolant Pump Model : LBK-MR-e Original Instructions Limited warranties 1. In the event of a failure or breakage under proper use of the product during the warranty period,

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information

Thank you for selecting the GD submersible grinder pump.

Thank you for selecting the GD submersible grinder pump. GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6

More information

GeyserMax-Flow Series

GeyserMax-Flow Series GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800

More information

Trouble Shooting Guide EWA, 3-phase (D2422)

Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide EWA, 3-phase (D2422) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Breaker tripped, no power to unit Loose wire Defective contactor or coil Close

More information

Instruction Manual. Coolant Pump. Model : : LHW-e / / LPW-e / / LPW-7W/ LKW-e / LFE LKW-e / LFE-e LFE / LFE-e. Original Instructions

Instruction Manual. Coolant Pump. Model : : LHW-e / / LPW-e / / LPW-7W/ LKW-e / LFE LKW-e / LFE-e LFE / LFE-e. Original Instructions Coolant Pump Instruction Manual Coolant Pump Model : : LHW-e / / LPW-e / / LPW-7W/ LKW-e / LFE LKW-e / LFE-e LFE / LFE-e Original Instructions Limited warranties 1. In the event of a failure or breakage

More information

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date: ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important

More information

Multi-stage Immersion Type VKB Series

Multi-stage Immersion Type VKB Series Coolant Pump Instruction Manual Multi-stage Immersion Type VKB Series VKB Series WARNING Do not hold the strainer (wire net) of the pump point at the handling of this product. Doing so may cause the strainer

More information

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS L-SERIES PUMPS Operating Manual Includes Pumps: L-305 L-310 1-877-80-PONDS www.atlanticwatergardens.com Introduction Thank you for selecting the TidalWave L-305/L-310 series pumps. Before using this pump

More information

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves Document No.: KE-4041-00 Operation Manual KITZ EKSR Series Spring Return Type Electric Actuators For KITZ Ball Valves Thank you for choosing KITZ products. For safe and trouble-free function and performance

More information

Submersible Pump Instructions. Safety Instructions

Submersible Pump Instructions. Safety Instructions Submersible Pump Instructions Safety Instructions Before operating of this pump, read this manual and follow all safety rules and operating instructions. Before operating of this pump, read this manual

More information

Self-Priming Centrifugal Pump Model: SP3 / SP / MSP / MTP SP3-e / SP-e / MSP-e / MTP-e

Self-Priming Centrifugal Pump Model: SP3 / SP / MSP / MTP SP3-e / SP-e / MSP-e / MTP-e Instruction Manual Self-Priming Centrifugal Pump Model: SP3 / SP / MSP / MTP SP3-e / SP-e / MSP-e / MTP-e Do not carry out operation, inspection or maintenance of the pump until you read this manual and

More information

TSURUMI MANUFACTURING CO., LTD.

TSURUMI MANUFACTURING CO., LTD. 17200075/B-10073-5 OM COMPACT SUBMERSIBLE SEMI-VORTEX PUMP OPERATION MANUAL FOR DEWATERING INTRODUCTION Thank you for selecting a Tsurumi Compact Submersible Semi-Vortex pump for your dewatering application.

More information

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps EI-700-005 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to

More information

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information

More information

Multi-stage Immersion Type

Multi-stage Immersion Type Coolant Pump Instruction Manual Multi-stage Immersion Type VKA/VKC Series WARNING Do not hold the strainer (wire net) of the pump point at the handling of this product. Doing so may cause the strainer

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

Submersible Stainless-Steel Cutter Pump OPERATION MANUAL

Submersible Stainless-Steel Cutter Pump OPERATION MANUAL 17240534/B-10040-7 BQ CQ Submersible Stainless-Steel Channel Impeller Pump Submersible Stainless-Steel Cutter Pump SFQ Submersible Stainless-Steel Centrifugal Pump OPERATION MANUAL INTRODUCTION Thank you

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m) Model T0828 Primary pump 1/HP 200 GPH Head of 20 (6 m) SUBMERSIBLE SUMP DUPLEX SYSTEM Professional Séries Discharge: 1 1/2 ABS DWV pipe Electric cable: 9 piggyback type Oil cooled Cast iron construction

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A) SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN INSTRUCTION MANUAL Version: 20110510 (for U.S.A) PREFACE Thank you very much for purchasing World Chemical s improved magnetic drive pump Submersible.

More information

GD series Submersible Grinder Pump

GD series Submersible Grinder Pump GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

Oil Pump. Features: AISIN aluminum die-casting technology allows for size and weight reduction.

Oil Pump. Features: AISIN aluminum die-casting technology allows for size and weight reduction. Oil Pump Engineered to exacting OE specifications, AISIN Oil Pumps deliver ideal oil pressure to the engine without creating excess load. Lubricating critical components to extend the life of the engine,

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS OWNER S MANUAL Model: PFUPPP2528251M10 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump ISP No: PFUPPP25-8/01/15 General Safety Information Before installation, read the following instructions carefully.

More information

Maintenance of Pleasureboat Diesel Engine GM Series

Maintenance of Pleasureboat Diesel Engine GM Series Maintenance of Pleasureboat Diesel Engine GM Series.Safety Precaution for Inspection )Battery Fluid Battery fluid is diluted sulfuric acid. It can blind you if it gets in your eyes, or burn your skin.

More information

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions Wilo SP Series Submersible Utility Pumps ETT ETT24-10.25 Installation and operating instructions 1. PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can be damaged during

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

Sanwa Stainless Steel Magnet Drive Pump Model MMP. Instruction Manual

Sanwa Stainless Steel Magnet Drive Pump Model MMP. Instruction Manual No. MMP01F(E)/1711 I.A. EDITION Sanwa Stainless Steel Magnet Drive Pump Model MMP Instruction Manual Note This instruction manual has been prepared for the personnel who will use the pump, so make sure

More information

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS CONTENTS INSTRUCTION MANUAL FOR LINEAR COMPRESSORS MODEL EL-60 EL-10W EL-80-15 EL-150 EL-80-17 EL-00 EL-100 1. Parts name. Instructions -1 Prior to operation 3 - Storage and transfer 3-3 Installation 4

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

Manufacturer Kakogawa, Japan DC5S

Manufacturer Kakogawa, Japan DC5S ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1

More information

Free Float Air Trap G8

Free Float Air Trap G8 172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1

More information

Owner s Manual GLASSLINED PUMP TANK

Owner s Manual GLASSLINED PUMP TANK Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that

More information

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd OWNER S MANUAL Submersible Sump Pumps Models: Suzhou Xin Qi Electric Co.,ltd www.xqepumps.com XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Installation/Operation For further operating, installation,

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Estimated Terminal Pressure Constant Control of Water Supply Unit

Estimated Terminal Pressure Constant Control of Water Supply Unit Instruction Manual Estimated Terminal Pressure Constant Control of Water Supply Unit NX-VFC-e Important Notice Thank you very much for purchasing the TERAL water supply unit. In order to use the water

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

STEP-BY-STEP INSTALLATION GUIDE

STEP-BY-STEP INSTALLATION GUIDE Battery Backup System STEP-BY-STEP INSTALLATION GUIDE Operating Instructions & Parts Manual ESP25 Please read and save these instructions. Read carefully before attempting to assemble, install, operate

More information

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps BP33 & BP50 0.3 & 0.5 HP @ 3450 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

VL-100U5-E (pull cord type) VL-100EU5-E (wall switch type)

VL-100U5-E (pull cord type) VL-100EU5-E (wall switch type) 1301875HF7701 Mitsubishi Lossnay Ventilator MODEL: VL-100U5-E (pull cord type) VL-100EU5-E (wall switch type) Installation Manual For Dealer and Contractor Please ensure that the separate Operating Instructions

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL IMPORTANT These instructions are intended as a guide for the Installing Contractor and as a reference for the Operator, Owner and Serviceman. RETAIN

More information

Submersible Effluent Pump

Submersible Effluent Pump ME45 Submersible Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When

More information

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) EOW-LB100-PNUS2 Thank you for purchasing this product from Tabuchi Electric. Read this User s Manual carefully to ensure safe use of

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No. Doc. No. APP 003U-03 INSTRUCTION GREASE PUMP PD110A50T MODEL No.851728 PD110A50T-SL MODEL No.851999 PD110A50 MODEL No.851779 DR110A50 MODEL No.851783 WARNING Prior to operating this pump, be sure to read

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

en Pump PS PS OPERATOR S MANUAL

en Pump PS PS OPERATOR S MANUAL 0154622en 002 0107 Pump PS 3 1500 PS 3 2200 OPERATOR S MANUAL 0 1 5 4 6 2 2 E N PS 3 1500/ PS 3 2200 Table of Contents 1. Foreword 3 2. Safety Information 4 2.1 Operating and Electrical Safety... 5 2.2

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A FILE No. A11-017 AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E PRINTED IN JAPAN, Jan. 2012, TDOC CONTENTS 1. Safety Precautions..................................3

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard

More information

Butterfly Valve Type 57P

Butterfly Valve Type 57P Butterfly Valve Type 57P Contents Lever Type: 50-200 mm (2-8 ) Body Material: CPVC Gear Type: 50-200mm (2-8 ) Body Material: CPVC (1) Be sure to read the following warranty clauses of our product 1 (2)

More information

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E TDG8000-3 TDG7000SE-3 TDG7000E TDG8000E TDGW7000SE TDG7000E3 TDGW8000E

More information

UZ Series. with Vortex Impeller OPERATION MANUAL

UZ Series. with Vortex Impeller OPERATION MANUAL 17238029/B-10024-9 INTRODUCTION UZ Series Submersible Sewage & Wastewater Pumps with Vortex Impeller OPERATION MANUAL Thank you for selecting the Tsurumi UZ Submersible Sewage & Wastewater Pumps. This

More information

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4

More information

INSTRUCTION ELECTRIC GREASE LUBRICATOR. ( AC-100V 50/60Hz ) EPL-100 MODEL No WARNING

INSTRUCTION ELECTRIC GREASE LUBRICATOR. ( AC-100V 50/60Hz ) EPL-100 MODEL No WARNING Doc. No. OSA037U-03 INSTRUCTION ELECTRIC GREASE LUBRICATOR ( AC-100V 50/60Hz ) EPL-100 MODEL No.880899 WARNING Prior to operating this pump, be sure to read this operation manual for safety. After reading

More information

Centrifugal PTO Pumps. 2 nd Edition

Centrifugal PTO Pumps. 2 nd Edition Centrifugal PTO Pumps 2 nd Edition MAN072 November 2005 2005 Centrifugal PTO pumps are manufactured by AMADAS Industries. You can find us on the Web at: www.amadas.com or e-mail us at: amadas@amadas.com

More information

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications) Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

AUTOMATIC SUBMERSIBLE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

L CR MAH

L CR MAH TECHNICAL SPECIFICATION FOR LI-ION L CR18650-2 0 0 0 MAH FILE NO. : DSE - LCR - L CR18650-2000 - V 17 A EDITION : V1 7 A DATE : 20 1 7 / 03 / 08 CYLINDRICAL RECHARGEABLE BATTERY Prepared By Checked By

More information

en Pump PS OPERATOR S MANUAL

en Pump PS OPERATOR S MANUAL www.wackergroup.com 0154618en 003 0107 Pump PS 2 400 OPERATOR S MANUAL 0 1 5 4 6 1 8 E N PS 2 400 Table of Contents 1. Foreword 3 2. Safety Information 4 2.1 Operating and Electrical Safety... 5 2.2 Information

More information

en Pump PSR1 500 OPERATOR S MANUAL

en Pump PSR1 500 OPERATOR S MANUAL 0171939en 002 1008 Pump PSR1 500 OPERATOR S MANUAL 0 1 7 1 9 3 9 E N PSR1 500 Table of Contents 1. Foreword 4 2. Safety Information 5 2.1 Operating and Electrical Safety... 6 2.2 Information Labels...

More information

ENGINE DRIVEN 3 FULL TRASH PUMP

ENGINE DRIVEN 3 FULL TRASH PUMP ENGINE DRIVEN 3 FULL TRASH PUMP MODEL NO: PF75 PART NO: 7230165 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0117 ISS 2 INTRODUCTION Thank you for choosing this Clarke Pump. The function

More information

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information

More information

Portable Oil Free Silent Series Compressor Operating Instructions

Portable Oil Free Silent Series Compressor Operating Instructions Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

KTV/NK Series. Submersible General Dewatering Pump OPERATION MANUAL

KTV/NK Series. Submersible General Dewatering Pump OPERATION MANUAL 17236124/B-10005-6 KTV/NK Series Submersible General Dewatering Pump OPERATION MANUAL INTRODUCTION Thank you for selecting the Tsurumi KTV/NK Series submersible general dewatering pump. This operation

More information

Operating Manual Includes Pumps: PG-9000 Part #R809606

Operating Manual Includes Pumps: PG-9000 Part #R809606 Operating Manual Includes Pumps: PG-9000 Part #R809606 Introduction Thank you for selecting the PG Series Pumps from Lifegard Aquatics. Before using this pump please take a moment to review this manual.

More information

Model: SPTOGT01 TRACTOR PTO GENERATOR

Model: SPTOGT01 TRACTOR PTO GENERATOR www.scintex.com.au sales@scintex.com.au Model: SPTOGT01 TRACTOR PTO GENERATOR SET UP, OPERATING, AND SERVICING INSTRUCTIONS Read this material before using this product. Failure to do so can result in

More information

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions

More information

SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN. INSTRUCTION MANUAL Version:

SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN. INSTRUCTION MANUAL Version: SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN INSTRUCTION MANUAL Version: 150908 PREFACE Thank you very much for purchasing World Chemical s submersible magnet drive pump SUBMERSE. To effectively use

More information

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL Flow Max Fluid Pump by Duraself OEM INSTALLATION MANUAL TABLE OF CONTENTS System and Safety Information 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3

More information

Instruction Manual LAMI CORPORATION INC.

Instruction Manual LAMI CORPORATION INC. Instruction Manual LAMI CORPORATION INC. Preface Thank you for purchasing our. This Instruction Manual (document) includes details for safe use of this product. Please read this document thoroughly before

More information

BEFORE USING THE PRODUCT

BEFORE USING THE PRODUCT HL-17015-5 BEFORE USING THE PRODUCT Thank you for purchasing an Oriental Motor product. Please read this BEFORE USING THE PRODUCT and the separate manual entitled OPERATING MANUAL thoroughly to ensure

More information

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English... P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Fax: 1-800-526-3757 E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com OWNER S MANUAL Submersible Waterfall/Utility Pumps 3384 0399

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz PFSPPPP Series PFSPCPC Series ISP No: PFSP33_50-4/2016 PFSPPPP33 / PFSPCPC50 Series General Safety Information

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

Internal Gear Pumps Installation Manual

Internal Gear Pumps Installation Manual Internal Gear Pumps Installation Manual MEDIUM HEAVY DUTY SERIES SIZE 2 PGI100-2-005 PGI100-2-006 PGI100-2-008 PGI100-2-011 PGI100-2-013 PGI100-2-016 PGI100-2-019 PGI100-2-022 PGI100-2-025 PGI100 MEDIUM

More information