1 1. Introduction VDF (Vortex Dynamic Filter) Instruction Manual CL-MR-series models Thank you for purchasing our product, NIKUNI VDF (Vortex Dynamic Filter). Please read this manual carefully and thoroughly before using the product to ensure correct and safe usage of the product, then keep the manual safe in a convenient place for future reference. VDF is the centrifugal solid-liquid separator. Several types, such as the basic VDF unit with no accessories, VDF with an adapter and legged VDF, are available so that you can select the most appropriate VDF for your application. Features of the individual models are as follows: CL-MR-series model: Have an underflow pipe submerged in water; it is suitable when bubbles forming in liquid are undesirable. (VDF UN with no accessories) Optional sludge pod enables batch processing of dirty concentrate. 2. For Safe Use In this manual, safety instructions are classified into two levels (Warning and Caution) to ensure correct and safe usage of the product and prevent injuries to the operator and bystanders as well as damage to property. Warning Caution Mishandling of the product can cause serious injury to the operator or bystanders or even death. Fully understand the meaning of the warning and be sure to follow the instructions. Mishandling can cause injury to the operator or bystanders, or damage to property. Fully understand the meaning of the caution and be sure to follow the instructions. Caution * Secure the product on a stable surface to prevent toppling/dropping, which may result in personal injuries or property damage. * Do not use the product for the purpose other than separating solid and liquid. Unintended use may result in the risk of unexpected personal injury or property damage. 3. Specifications Common Specifications (VDF) Material of the main body PA6 Particle size (μm) for which 90% filtration is achieved (in terms of iron) 20 Applicable fluid Water, water-soluble fluid (with a kinetic viscosity of up to 2cSt) Sludge specific gravity Equal to or greater than 2.7 Max. Operating Temperature 40 Max. Operating inner pressure 0.25MPa Basic VDF UN with no accessories Pump head (m) CL-30MR CL-30NMR Fluid supply Clean liquid flow CL-65MR CL-65NMR Fluid supply Clean liquid flow CL-100MR CL-100NMR Fluid supply Clean liquid flow Depending on the pump used and piping installed, the amount of clean fluid may differ. Therefore, please pay attention when making a selection. The recommended supply pressure for VDF is in the range of MPa. Specifications (Sludge pod) Material Applicable fluid Body: PET Cover: PA6 Water, water-soluble fluid (with a kinetic viscosity of up to 2cSt) Max. Operating Temperature 40 Max. Operating inner pressure 0.15MPa 1
2 4. Part Names and Dimensions Basic VDF (with no accessories) Dimensions (unit: mm) Fig. 1 Type A B C D E F G H J K X Y Z Weight (g) CL-30MR R1/2 R3/4 R3/8 225 CL-30NMR R1/2 R3/4 NPT3/8 225 CL-65MR R3/4 R1 R1 400 CL-65NMR R3/4 NPT1 NPT1 400 CL-100MR R1 R1 R1 750 CL-100NMR NPT1 NPT1 NPT1 750 This product is the molding (resin). The tolerance is ±2mm unless otherwise noted. Sludge Pod Dimensions (unit: mm) Fig. 2 Type R S T U Weight (g) SPD-100P R1 R1 1/4 600 SPD-100NP NPT1 NPT1 1/4 600 This product is the molding (resin). The tolerance is ±2mm unless otherwise noted. Sludge pods are emptied either via a manual ball valve or an automated adjustable timer controlled air-operated ball valve 2
3 5. Instructions for Installation and Operation Instructions common to all VDF types 1) Install the underflow pipe vertically with its outlet pointing downward. 2)When installing this, use piping joints to connect it to the liquid inlet and underflow. Attach support equipment such as U-bolts to the joints and main body to prevent rotation and toppling. If using a sludge pod, attach support equipment to the main body of the valve so that a load is not placed on the VDF or sludge pod when operating the valve. 3) If connecting screwed piping joints, use sealing tape and take care not to deform the areas on the main body where the screws are attached. Also, be aware that liquid may leak if the screws are too loose or breakage may occur if they are too tight. 4) Use only the fluid whose kinetic viscosity does not exceed 2 cst and whose sludge specific gravity is equal to or greater than 2.7. Fluid with higher viscosity or smaller sludge specific gravity will impair the sludge-removing performance. 5) Take extra care in selecting a pump. Pump performance would affect the amount of clean liquid and the sludge-removing performance even if the same type of VDF is used. The recommended pump supply pressure (to VDF) is between 0.15 and 0.25 MPa. 6) Bore diameter of the overflow pipe should be equal to or greater than the bore diameter of VDF connection. Immediately down to the next short nipple and elbow. When connected to a vertically upward, clean fluid flow decrease in, fluid will increase the underflow. 7) Be aware that the amount of clean liquid and the sludge-removing performance will change if a cartridge filter is directly connected to the overflow pipe. All the fluid will be drained through the underflow pipe once the cartridge filter starts clogging. 8) Install a pressure gauge immediately upstream of the feed and make a monthly check to assure that the normal supply pressure is maintained (i.e. an abnormal pressure of less than 0.15 MPa or equal to or greater than 0.25 MPa is not observed) and both overflow and underflow run smoothly. 9) Liquid may not be discharged from the underflow if the level of the liquid in the VDF underflow container is higher than that in the clean tank, as shown in the reference flow chart below. In this case, the solutions in the table below are recommended. Situation (Example) If a sediment tank is installed but there is no overflow from the sediment tank. Reference flowchart 3
4 Recommended solutions Install a valve for adjusting the underflow liquid volume on the VDF overflow pipe and adjust this. When doing so, install a compound gauge immediately before the valve and check that the pressure differential between the areas on either side of the VDF is between 0.15MPa and 0.25MPa. *Attach support equipment to the pipe so that a load is not placed on the main body of the VDF when the valve is attached. Solution flowchart 10) Be aware that if the level of the liquid in the VDF underflow container is lower than that in the clean tank, the underflow liquid volume (dirty liquid volume) may increase while the overflow liquid volume (clean liquid volume) decreases, as shown in the reference flow chart below. Avoid connecting an adjustment valve to the underflow to adjust the underflow liquid volume (dirty liquid volume). Strong VDF vortexes may wear out the valve and cause an imbalance in the adjustment, or sludge may accumulate and block the valve. Reference flowchart Nikuni Jaguar range offers semi-automatic systems 4
5 Instructions for Basic VDF UN 1) Do not reduce the bore diameter of the underflow pipe. Ensure that the hose connected to the underflow pipe does not bend in any way. 2) Install the underflow pipe vertically and ensure that the shortest pipe length is achieved to prevent sludge accumulation in the pipe. Such accumulation will impair sludge-removing performance. 3) Submerge the end of the underflow pipe between 200mm and 500mm below the surface of the liquid in the tank. If it is not submerged, air will enter, reducing the overflow volume and creating more bubbles. If it is submerged less than 200mm below the surface, air near the surface may be sucked in. If it is submerged further than 500mm below the surface, this will decrease the overflow volume. 4) Be aware that liquid will be siphoned from one tank to another if the liquid level differs between the two tanks at the time when the pumping operation stops. This may cause sludge to be transferred to the clean side. Take measures to prevent this such as installing a siphon break. An example of how CL-LW-series VDF (Basic VDF) is used Overflow (Clean liquid) Underflow (Dirty concentrate) Feed Pressure gauge Supply port Submergence depth: Between 200mm and 500mm 6. Options Sludge pod A sludge pod achieves the reduction in the amount of underflow by concentrating separated sludge. An example of how a sludge pod is used Overflow (Clean liquid) Pressure gauge Supply port Instructions for sludge pod 1) If you want to mount an optional sludge pod to your VDF, select a sludge pod whose bore diameter is equal to or greater than the bore diameter of the underflow pipe and connect the pod to the underflow pipe. 2) Open and close the underflow pipe outlet on a regular basis by using a valve. Too much sludge accumulation in the sludge pod may lead to clogging. Feed Sludge pod Should be mounted with the top of the cone pointing downward Underflow (Dirty concentrate) Valve The Nikuni C-CAT concept offers the option of creating bespoke standalone complete VDF kits including either the CL-MR resin series or the CL-LW SCS13 stainless steel series 5
6 7. Repair and Warranty Information If you need repair or warranty service for the product you purchased, contact us or the distributor from whom you purchased it. The free-repair warranty we offer is as follows: 1. We offer free repair within one year from the delivery date. 2. If a product has any defect or damage caused by NIKUNI s faulty design or poor workmanship within the warranty period while it is being used properly, it will be repaired for no charge. 3. However, repair will be charged in the following cases: 1)Any defect or damage that manifests itself after the expiration of the warranty period 2)Any defect or damage caused by abnormal use or storage 3)Any defect or damage due to fire, natural disaster, or other force majeure 4)Any defect or damage resulting from the replacement of any parts by the customer 5)Any defect or damage resulting from repair or modification by the customer 4. This warranty does not cover any other expenses associated with the defect that has occurred during the normal use of the product. If you suspect/detect an abnormal condition during the use of the product, immediately stop the operation to check if there really is a defect. If you find any defect, contact us immediately and state the type name and serial number given on the nameplate as well as details of the defect. 5. Differences in the warranty for products used in Japan and those used in foreign countries or region are as follows: 1) If a product has any defect or damage caused by NIKUNI s manufacturing fault within the warranty period while it is being used properly, repair part(s) will be provided for no charge. 2) Defective part(s) shall be returned to us for our investigation of the problem; however, replacement part(s) may be sent prior to receipt of the return depending on the circumstances. In such a case, defective part(s) should be returned later for our investigation. If the investigation proves that we are not responsible for the defect, replacement part(s) will be charged. Please feel free to contact us if you have any further questions about the product you purchased. Nikuni Co., Ltd Head Office: Kuji, Takatsu-ku, Kawasaki City, Kanagawa JAPAN TEL: (Main Switchboard), FAX: Website: Location: Sheffield UK The Nikuni VDF CL-MR series of resin bodied hydrocyclones are available in single unit capacities of up to 100 lpm The Nikuni NAX series offers fully automated systems in a number of formats and capacities All Nikuni hydrocyclones can be arranged in multiple unit installations to provide high-capacity separation for large flows The Nikuni VDF CL-LW series of SCS13 stainless steel bodied hydrocyclones are available in single unit capacities of up to 300 lpm 6
Manufacturer Kakogawa, Japan DC5S
ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1
More informationAir Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.
172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents
More informationWilo Abrasive Separator SCP and NL Kits Installation and operating instructions
Wilo Abrasive Separator SCP and NL Kits Installation and operating instructions WIL-IO-AS-001-11 1 Description 2 Performance Characteristics The Abrasive (Sediment) Separator [AS] is used to remove fine
More informationPL Submersible, Semi-Vortex, Water Feature Pump
TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and
More information3M TM Filter Housing 1BS-T/1BS-TW Series
READ FIRST 3M TM Filter Housing 1BS-T/1BS-TW Series Operation Manual CONTENTS Introduction 1 For Your Safety 1,2 Attention to galling or seizure of treaded portions 2 Specifications 3 Part names 4 Installation
More informationSeparator Systems Operations & Maintenance Manual
Separator Systems Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages, Separators
More informationGRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions
GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects
More informationFloat Dynamic Steam Trap J10
172-65237MA-01 (J10) 12 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Float Dynamic Steam Trap J10 Copyright 2015 by TLV CO., LTD. All rights reserved
More informationMASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL
MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL INSTALLATION: CHOOSING THE LOCATION: Locate the coalescer as near to the intended point of use as possible. Avoid high
More informationPneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.
Pneumatic Drive Type Drill Bit Breakage Detection Sensor DFM3 Series The World's First!! Pneumatic-Drive Type Catalog / Instruction Manual US.PAT. Pneumatic Drive Type Drill Bit Breakage Detection Sensors
More informationFree Float Air Trap G8
172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1
More informationSUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)
SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN INSTRUCTION MANUAL Version: 20110510 (for U.S.A) PREFACE Thank you very much for purchasing World Chemical s improved magnetic drive pump Submersible.
More informationRetro Kit 200 / 300. Installation & Operating Instructions. Note: Do not attempt to install this Module without first reading this manual thoroughly
Retro Kit 200 / 300 Installation & Operating Instructions Note: Do not attempt to install this Module without first reading this manual thoroughly Manufactured by Evolution Aqua Ltd Evolution House Kellett
More informationNew & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment
New & Improved VariFlo Plural Component Equipment Low Pressure Polymer Dispensing Equipment Table of Contents Page One Page Two Page Three Page Four Page Five Page Six Page Seven Page Eight Page Nine Page
More informationSERVICE & OPERATING MANUAL
SERVICE & OPERATING MANUAL 8-4 Mud Cleaner (03-00-060) INTRODUCTION The Triflo 8-4 Mud Cleaner is capable of processing up to 520 gallons per minute and can get do to cut point of approximately 35 microns.
More informationOPERATING MANUAL. Black Bruin Hydraulic Rotators
OPERATING MANUAL All information given in this manual is current and valid according to the information available at the time of publication. Sampo Hydraulics Ltd. reserves the rights to implement changes
More informationUNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSubmersible Mixed Flow/Axial Flow Pump Model SAM Model SPM
Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial
More informationSurplussing Valve SP-COSR-16
172-65409MA-00 (SP-COSR-16) 20 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Surplussing Valve SP-COSR-16 Copyright 2013 by TLV CO., LTD. All rights
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationFree Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8
172-65144MA-05 (JA Series) 29 July 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 Copyright
More informationPortable Oil Free Silent Series Compressor Operating Instructions
Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com
More informationTuffy Liquid Level Controls with Pneumatic Switch
Tuffy Liquid Level Controls with Pneumatic Switch Installation and Operating Manual Side Mounted Float Level Switch Read this Manual Before Installing This manual provides information on the Tuffy Liquid
More informationRead and understand this manual for safely usage.
TS02-0183 INSTRUCTION MANUAL FOR GUARD TYPE LEVEL SENSOR MODEL:FC Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for
More information- click here for pricing and ordering
www.pumpagents.com - click here for pricing and ordering No. 51-038 Mar. 01, 2006 MD-40R MD-40RX MD-40RZ(-5) Item Description Q'ty Material Part No. Part No. Part No. 1 Front Casing Unit 1 GFRPP+PTFE MD0053
More informationPACKING, HANDLING, TRANSPORTING AND STORING MOTORS
PACKING, HANDLING, TRANSPORTING AND STORING MOTORS Make sure that the shaft of the motor is not loaded in any way and is protected from knocks. Axial loads or shocks may easily damage the bearings inside
More informationMedium and high pressure pumps
Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation
More informationTypical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application
Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application Mohr Separations Research Model MSR-33 S Separator Customer: Background
More informationFX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.
FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. 1. This document may not be reproduced, in whole or part, in any form or by any means without the prior written permission
More informationUNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationUNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationMatala. VersiFlow Series. Instruction and Maintenance Manual
VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationSANWA STAINLESS STEEL MAGNET DRIVE PUMP INSTRUCTION MANUAL. Request to Users
SANWA STAINLESS STEEL MAGNET DRIVE PUMP MAGPAC SERIES MP/MH/ML INSTRUCTION MANUAL Request to Users This instruction manual is intended for the actual user, and should be turned over to the supervisor of
More informationThank you for selecting the GD submersible grinder pump.
GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6
More informationConstant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual
Serial No. H-V019-E-6 Constant Flow Valves User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation
More informationSAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors
SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors www.chinawinches.cn (Dimension: inch) Brief Performance Table of Sai GM Series Piston Hydraulic Motor (Full range GM05- GM9 series)
More informationSELF-CLEANING FILTER
SELF-CLEANING FILTER CT0126.0_00 UK November 2008 PRODUCTION RANGE Connections Standard Mesh [μm] Size Code Kv [m³/h] THREADED FF UNI-EN-ISO 228 100 3/8 126.03.10 1,80 1/2 126.04.10 3,10 3/4 126.05.10
More informationINSTRUCTION OIL PUMP. SH-110A5 MODEL No DR-110A5 MODEL No PD-110A5 MODEL No WARNING
Doc. No. APP 004U-04 INSTRUCTION OIL PUMP SH-110A5 MODEL No.851753 DR-110A5 MODEL No.851754 PD-110A5 MODEL No.851755 WARNING Prior to operating this pump, be sure to read this operation manual for safety.
More informationINSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH
INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF11-610-603 MM4-610-603 Made in the U.S.A. by Plastic Process Equipment, Inc. copyright 2006 RECEIVING: Please thoroughly inspect your Hydraulic Oil Filtration
More informationGD series Submersible Grinder Pump
GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output
More informationPowerLink GW series Eddy Current Dynamometer User Manual
PowerLink GW series Eddy Current Dynamometer User Manual XiangYi (Hong Kong) Power Testing Instrument Co. Ltd. 0 GW Series Eddy Current Dynamometer User Manual Transport, Storage, use of environmental
More informationVERTICAL MULTI-STAGES CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:
More informationHE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also
T HE Stewart Vacuum Gasoline System employs a small tank, installed under the hood. This tank is connected by brass tubing to the intake manifold, also to gasoline supply tank, and to carburetor. Every
More informationHydraulic Transmission Jack, Telescopic
Operating Instructions & Parts Manual Hydraulic Transmission Jack, Telescopic Model 4000 400 (Air Operated) Capacity 000 lbs. 000 lbs. Model 4000 Model 400 U.S. Patent No. 6,02,377! This is the safety
More informationUSER S MANUAL FOR F & Q. Submersible Sewage Pumps
USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and
More information0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual
0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5 owner s manual GB You have just become the owner of one of the latest in the line of DOSATRON proportional dosing pumps and we congratulate you on your choice.
More informationBattery Powered Hydraulic Pump; Kit PN [ ]
ORIGINAL INSTRUCTIONS Battery Powered Hydraulic Pump; Kit PN 1804111-[ ] Customer Manual 409-10060 16 NOV 16 Rev D SAFETY PRES IMPORTANT SAFETY INFO READ THIS FIRST!... 2 SAFETY PRES AVOID INJURY READ
More informationSanwa Stainless Steel Magnet Drive Pump Model MMP. Instruction Manual
No. MMP01F(E)/1711 I.A. EDITION Sanwa Stainless Steel Magnet Drive Pump Model MMP Instruction Manual Note This instruction manual has been prepared for the personnel who will use the pump, so make sure
More informationOperating Manual Model 3023
Operating Manual Model 3023 1210 Toovey Road Kelowna, BC Canada V1X 6R4 Phone 250.765.9452 joeh@fluidservicetech.com SAFETY PRECAUTIONS BEFORE STARTING VEHICLE, BE SURE ALL HOSES AND ATTACHMENTS ARE CLEAR
More informationRead and understand this manual for safely usage.
TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard
More informationPICO Cleaning Instructions
PICO Cleaning Instructions How to clean PICO piezoelectric metering valves IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors Electronic pdf files of EFD manuals are also available
More informationUnilift KP 150, KP 250, KP 350
GRUNDFOS INSTRUCTIONS Unilift KP 150, KP 250, KP 350 Installation and operating instructions DRAINAGE PUMP 1Z28 LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted
More informationCOOL DRAFT INSTRUCTIONS OWNER S MANUAL CONTENTS. Cool Draft MiniMister 14 Misting Fan CDMP1420BLU
COOL DRAFT BY INSTRUCTIONS OWNER S MANUAL! Keep for future reference. Common problems and solutions are listed within this booklet. IMPORTANT INFORMATION INSIDE: Read, understand, and follow all safety
More informationSeries 867 Reduced Pressure Zone Assemblies
RP/IS-F-867 INSTALLATION INSTRUCTIONS Series 867 Reduced Pressure Zone Assemblies 2 1 2" 3" (65 80mm) INDEX 867-NRS Installation Instructions....................................... 2-3 Service, Repair
More informationHANDLING MANUAL FILTERS & PRESSURE TANKS
HANDLING MANUAL FILTERS & Basic Operation / Maintenance / Warranty INDEX A - Basic Operations A.1- Lifting and Unload...3 - Horizontal Tanks and Filters...3 - Vertical Tanks and Filters...4 - Important
More informationChip Vacuum Removal System INSTRUCTION MANUAL
Chip Vacuum Removal System INSTRUCTION MANUAL GREEN ECO PRO Co.,Ltd. e-mail:service@rwwa.com.tw 427 Model: Serial No. Manufacture Date: FC Version : SM December 2017 FC-SERIES Dimension & Carton FC-180
More informationInstruction Manual. LG-100 Series Pointer-type Liquid Level Gauge
Instruction Manual LG-100 Series Pointer-type Liquid Level Gauge Thank you for choosing our product. Our liquid level gauge is designed and produced, based on the specification of installation and measurement
More informationES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min
Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream
More informationINSTRUCTION GRIP METER. LBM-G MODEL No LUBE BATCH METER. LBM-60 MODEL No LBM-30 MODEL No LBM-16 MODEL No.
Doc. No. OSA 057U-00 INSTRUCTION GRIP METER LBM-G MODEL No.801428 LUBE BATCH METER LBM-60 MODEL No.801429 LBM-30 MODEL No.802238 LBM-16 MODEL No.802237 WARNING Prior to operating this pump, be sure to
More informationHTX-HTH SEPARATORS I&O MANUAL
INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17) TABLE OF CONTENTS Table of Contents...
More informationOPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction
Mechatronics Group OPERATION MANUAL Diaphragm Pump TD/TD2 Series TD-08, 15, 20/TD2-25 Thank you for purchasing Diaphragm Pump. Introduction This operation manual describes how to ensure safe and prolonged
More informationSERIES PC INSTRUCTION AND OPERATION MANUAL
MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this
More informationHydronic Corporation
Hydronic Corporation Air Driven Hydraulic Pumps and Intensifiers P825 Installation, Use and Maintenance Manual Contents Introduction, Guarantee and Identification Plate Description, Start Up Procedures
More informationInstallation & Operating Manual
Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been
More informationSUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN. INSTRUCTION MANUAL Version:
SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD-5002GWN INSTRUCTION MANUAL Version: 150908 PREFACE Thank you very much for purchasing World Chemical s submersible magnet drive pump SUBMERSE. To effectively use
More informationSubmersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)
Instruction Manual Installation Manual Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Thank you for your purchase of Teral (Volute) Submersible Turbine Pump. To the customers
More informationTRANSFER PUMP INSTRUCTIONS P/N 14251NOS
TRANSFER PUMP INSTRUCTIONS P/N 14251NOS A5048-SNOS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death
More informationOWNER S TECHNICAL MANUAL
OWNER S TECHNICAL MANUAL 1 2 Air Operated Diaphragm Pump NDP- 15FPH 1. Names of parts and materials (excluding FP ) A. Air Valve B. Reset Button C. Out Manifold D. Out Chamber E. In Manifold F. Pump Base
More informationVAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR
VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR GENERAL INFORMATON Evoqua s VAF TM brand Hydrocyclone Separators are effective in removing suspended particles from any flow stream of water where the specific
More informationTable of Contents. AMO series quantitative pressured centralized lubricating system 1. Illustration of AMO motor driven lubricating system 1
Table of Contents AMO series quantitative pressured centralized lubricating system 1 Illustration of AMO motor driven lubricating system 1 AMO motor driven thin oil lubricating pump MO type pressured thin
More informationAir Operated Diaphragm Pumps Operating and Maintenance Instructions
Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,
More informationMR 5-30 Aviation Fuel Meter Owner s Manual
SAVE THESE INSTRUCTIONS 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 MR 5-30 Aviation Fuel Meter Owner s Manual TABLE OF CONTENTS General Information... 2
More informationSUBMERSIBLE SUMP PUMPS
SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing
More informationInstallation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS
Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS IMPORTANT - WARRANTY CLAUSE ROTECH PUMPS: Pumps manufactured & assembled by Rotech, are covered by warranty for free of manufacturing
More informationOWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER
OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Centrifugal Pump Primer 383 0893 MODEL 6D, HAN-DEE PRIMER IMPORTANT For best possible performance continuous, satisfactory operation,
More informationG8 Portable Fuel Transfer Pump Owner s Manual
G8 Portable Fuel Transfer Pump Owner s Manual GENERAL INFORMATION This pump is designed for use only with gasoline (up to 15% alcohol blends such as E15), diesel fuel (up to 20% biodiesel blends such as
More informationEP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual
EP1306N Operation Manual 1 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK 2 TABLE OF CONTENTS SECTION 1: SAFETY... 4 1. GENERAL SAFETY... 5 2. PUMP SAFETY... 5 3. FLUID PRESSURE AND COMPATIBILITY... 6 4.
More informationD Instructions/Parts. Siphon Feed Detail Spray Gun D
Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
More informationAUTO REWIND AIR HOSE REEL
Model #s 46845, 46848 AUTO REWIND AIR HOSE REEL OPERATOR S MANUAL STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!? NEED HELP? Save time, contact us first. 888-648-8665 support@tekton.com WARNING:
More informationInstallation, Operation and Maintenance Instructions
SM-141 Installation, Operation and Maintenance Instructions MAGNEtic humps & round pipe separators ERIEZ WORLD HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1402 U.S.A. WORLD AUTHORITY IN SEPARATION TECHNOLOGIES
More informationCentrifugal Separator Operations & Maintenance Manual
Centrifugal Separator Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages,
More informationSpeed Controller High Flow
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Speed Control Valve for High Speed Cylinder High Flow Speed Control Valve for Actuator. High Flow Type with Same Size as. Suitable for
More informationRoutine Compressor Maintenance
Establishing a regular, well-organized maintenance program and strictly following it is critical to maintaining the performance of a compressed air system. One person should be given the responsibility
More informationDiaphragm Valves Type 15
Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for
More informationWastewater Air Release Valve Models 48A, 49A
Manual No. WWAR-OM1-2 Wastewater Air Release Valve Models 48A, 49A Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationTECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)
1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler
More informationINSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.
Doc. No. APP 003U-03 INSTRUCTION GREASE PUMP PD110A50T MODEL No.851728 PD110A50T-SL MODEL No.851999 PD110A50 MODEL No.851779 DR110A50 MODEL No.851783 WARNING Prior to operating this pump, be sure to read
More informationOperating and Assembly Manual
Model 455-IC/PRO/H Operating and Assembly Manual Midwest Equipment Manufacturing, Inc. 5225 Serum Plant Road Thorntown, IN 46071 03-08-12 SAFETY RULES Remember, any power equipment can cause injury if
More informationMK Series - High Performance Butterfly Valves Operation and Maintenance Instructions
COMMERCIAL Bray Controls Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdivision.com MK Series - High
More informationContents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V034-E-12 Sediment strainer (Type Y) Contents (page) (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions 2 (3) General instructions
More informationLIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS
This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS Instruction & Parts Manual This manual covers the following
More informationCoolant Purification Systems Ultra 90 INSTRUCTION MANUAL
Coolant Purification Systems Ultra 90 INSTRUCTION MANUAL Model: Ultra 90 Serial No. Manufacture Date: Revision: E September 2016 Unit Foot Print & Layout Description of each components Installation Guide
More informationVERTICAL MULTI-STAGE CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN
More information75500MAX Series and 75500MAXM Series
75500MAX Series and 75500MAXM Series Marine Fuel Filter/Water Separators Instruction Part Number 15349 Rev E Racor Turbine Series fuel filter/ water separators protect the precision components of your
More informationMGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.
Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important
More informationMODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat.
FORM NO. 94-7276 MODEL NO. 41026-60101 & UP OPERATOR S INSTRUCTIONS HOSE REEL KIT To assure maximum safety, optimum performance, and to gain knowledge of the product, it is essential that you or any other
More informationOperating and Assembly Manual
Model 455-IC/PRO/H Operating and Assembly Manual Palmor Products Inc. 5225 Serum Plant Road Thorntown, IN 46071 03-08-12 SAFETY RULES Remember, any power equipment can cause injury if operated improperly
More informationEngineering Standard. Fig 707 Safety Relief Valve Installation and Maintenance Instructions
ES/707/0/003 ES/707/0/003 June 2007 Engineering Standard Fig 707 Safety Relief Valve Installation and Maintenance Instructions Sharp Street, Worsley, Manchester M28 3NA: Tel +44 (0) 161 790 7741 Fax +44
More informationVal-Matic 1-4 Combination Air Valve (Single Housing Type)
Manual No. ARCO-OM1-2 Val-Matic 1-4 Combination Air Valve (Single Housing Type) Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1
More information